EXHIBIT 1
SETTLEMENT AGREEMENT BETWEEN 
THE UNITED STATES OF AMERICA
AND
THE IOWA CITY COMMUNITY SCHOOL DISTRICT

Back to Settlement Agreement

  1. Route to Play Areas – General

    Violation – The routes to play areas contain multiple barriers to access.

    Requirement – At least one accessible route shall connect accessible buildings, accessible facilities, accessible elements, and accessible spaces that are on the same site. 2010 Standards §§ 206.2.2, 206.2.17, 402.2, 1008.2 Chapter 4.

    Elementary School(s)

    Completion Date

    Projected Completion

    If not completed, Architectural plans needed? Y/N

    1. Coralville Central

    2018

     

     

    2. Kirkwood

     

    12/1/2021

    Yes

    3. Lemme

     

    12/1/2022

    Yes

    4. Weber

    2017

     

     

    5. Wickham

     

    12/1/2022

    Yes

    6. Wood

    7/1/2019

     

     

  2. Route to Play Areas – Walking Surfaces

    Violation – The ground surface of the route from walkways to play areas is grass or dirt.

    Requirement – Floor and ground surfaces shall be stable, firm, and slip resistant. 2010 Standards §§ 206.2.2, 402.2, 403.2, 302.1.

    Elementary School(s)

    Completion Date

    Projected Completion

    If not completed, Architectural plans needed? Y/N

    1. Kirkwood

     

    12/1/2021

    Yes

    2. Lemme

     

    12/1/2022

    Yes

    3. Wood

    7/1/2019

     

     

  3. Route to Play Areas – Walking Surfaces

    Violation – The gap between the walkway and the blacktop exceeds ½ inch.

    Requirement – Openings in floor or ground surfaces shall not allow passage of a sphere more than ½ inch diameter. 2010 Standards §§ 206.2.2, 402.2, 403.2, 302.3.

    Elementary School(s)

    Completion Date

    Projected Completion

    If not completed, Architectural plans needed? Y/N

    1. Kirkwood

    7/1/2019

     

     

  4. Route to Play Areas – Walking Surfaces

    Violation – The slope of portions of the route exceeds 1:20 (5.0%).

    Requirement – The running slope of walking surfaces shall not be steeper than 1:20. 2010 Standards §§ 206.2.2, 402.2, 403.3

    Elementary School(s)

    Completion Date

    Projected Completion

    If not completed, Architectural plans needed? Y/N

    1. Coralville Central

    2018

     

     

    2. Horn

     

    12/1/2022

    Yes

    3. Lemme

     

    12/1/2022

    Yes

    4. Weber

    2017

     

     

    5. Wickham

     

    12/1/2022

    Yes

  5. Route to Play Areas – Walking Surfaces

    Violation – The cross slope of portions of the route exceeds 1:48 (2.08%).

    Requirement – The cross slope of walking surfaces shall not be steeper than 1:48. 2010 Standards §§ 206.2.2, 402.2, 403.3

    Elementary School(s)

    Completion Date

    Projected Completion

    If not completed, Architectural plans needed? Y/N

    1. Kirkwood

     

    12/1/2021

    Yes

    2. Weber

    2017

     

     

    3. Wickham

     

    12/1/2022

    Yes

  6. Route to Play Areas – Walking Surfaces

    Violation – Changes in level between walking surfaces and play areas exceed ½ inch.

    Requirement – Changes in level greater than ½ inch high shall be ramped. 2010 Standards §§ 206.2.2, 402.2, 403.4, 303.4

    Elementary School(s)

    Completion Date

    Projected Completion

    If not completed, Architectural plans needed? Y/N

    1. Borlaug

    7/26/2019

     

     

    2. Coralville Central

    10/25/2018

     

     

    3. Hoover East

    10/19/2018

     

     

    4. Kirkwood

     

    12/1/2021

    No

    5. Penn

     

    12/1/2020

    No

    6. Weber

    7/24/2019

     

     

    7. Wickham

     

    12/1/2022

    No

    8. Wood

    10/8/2019

     

     

  7. Route to Play Areas – Gate

    Violation – The maneuvering clearance at the gate to the play area is not level.

    Requirement – Floor or ground surface within required maneuvering clearances shall not exceed 1:48. 2010 Standards §§ 206.5.1, 404.2.4.4

    Elementary School(s)

    Completion Date

    Projected Completion

    If not completed, Architectural plans needed? Y/N

    1. Kirkwood

    2019

     

     

  8. Route to Play Areas – Ramp

    Violation – Handrails are not provided on both sides of the ramp.

    Requirement – Handrails shall be provided on both sides of ramps. 2010 Standards §§ 206.2.2, 402.2, 405.8, 505.1, 505.2

    Elementary School(s)

    Completion Date

    Projected Completion

    If not completed, Architectural plans needed? Y/N

    1. Wickham

     

    12/1/2022

    Yes

  9. Route connecting Play Components – General

    Violation – The route connecting ground level play components and elevated play components contains multiple barriers to access.

    Requirement – Where separate play areas are provided within a site for specific age groups, each play area shall be accessible. At least one accessible route shall be provided within the play area. 2010 Standards §§ 206.2.17.1, 240.1, Chapter 4

    Elementary School(s)

    Completion Date

    Projected Completion

    If not completed, Architectural plans needed? Y/N

    1. Alexander

    10/19/2018

     

     

    2. Borlaug

    7/26/2019

     

     

    3. Coralville Central

    10/25/2018

     

     

    4. Hoover East

    10/19/2018

     

     

    5. Horn

    9/27/2018

     

     

    6. Kirkwood

    10/11/2018

     

     

    7. Lemme

    9/7/2018

     

     

    8. Penn

    8/28/2019

     

     

    9. Shimek

    9/12/2018

     

     

    10. Weber

    7/24/2019

     

     

    11. Wickham

    8/13/2019

     

     

    12. Wood

    10/8/2019

     

     

  10. Route connecting Play Components – Engineered Wood Fiber Surface

    Violation – No ground level play components are provided on an accessible route.

    Requirement – Where ground level play components are provided, at least one of each type shall be on an accessible route. Where elevated play components are provided, additional ground level play components shall be provided in accordance with Table 240.2.1.2. 2010 Standards §§ 206.2.17.1, 240.2.1

    Elementary School(s)

    Completion Date

    Projected Completion

    If not completed, Architectural plans needed? Y/N

    1. Alexander

     

    12/1/2021

    No

    2. Borlaug

    7/26/2019

    12/1/2021

    No

    3. Coralville Central

    10/25/2018

     

     

    4. Hoover East

    10/19/2018

     

     

    5. Horn

    9/27/2018

     

     

    6. Kirkwood

     

    12/1/2021

    No

    7. Lemme

    9/7/2018

    12/1/2021

    No

    8. Penn

    8/28/2019

    12/1/2020

    No

    9. Shimek

    9/12/2018

     

     

    10. Weber

    7/24/2019

     

     

    11. Wickham

    8/13/2019

     

     

    12. Wood

    10/8/2019

     

     

  11. Route connecting Play Components – Engineered Wood Fiber Surface

    Violation – An accessible route does not connect to the entry and exit points of 50% of the elevated play components.

    Requirement – Where elevated play components are provided, at least 50 percent shall be on an accessible route. The accessible route shall connect the entry and exit points of the play components. 2010 Standards §§ 206.2.17.1, 240.2.2

    Elementary School(s)

    Completion Date

    Projected Completion

    If not completed, Architectural plans needed? Y/N

    1. Alexander

    10/19/2018

     

     

    2. Borlaug

    7/26/2019

     

     

    3. Coralville Central

    10/25/2018

     

     

    4. Hoover East

    10/19/2018

     

     

    5. Horn

    9/27/2018

     

     

    6. Kirkwood

    10/11/2018

     

     

    7. Lemme

    9/7/2018

     

     

    8. Penn

    8/28/2019

     

     

    9. Shimek

    9/12/2018

     

     

    10. Weber

    7/24/2019

     

     

    11. Wickham

    8/13/2019

     

     

    12. Wood

    10/8/2019

     

     

  12. Route connecting Play Components – Engineered Wood Fiber Surface

    Violation – The slope of portions of the route connecting ground level play components and elevated play components exceeds 1:16 (6.25%).

    Requirement – Ramp runs connecting ground level play components shall have a running slope not steeper than 1:16. 2010 Standards §§ 206.2.17.1, 240.2.1, 240.2.2, 1008.2.5.1

    Elementary School(s)

    Completion Date

    Projected Completion

    If not completed, Architectural plans needed? Y/N

    1. Alexander

    10/19/2018

     

     

    2. Borlaug

    7/26/2019

     

     

    3. Coralville Central

    10/25/2018

     

     

    4. Hoover East

    10/19/2018

     

     

    5. Horn

    9/27/2018

     

     

    6. Kirkwood

    10/11/2018

     

     

    7. Lemme

    9/7/2018

     

     

    8. Shimek

    9/12/2018

     

     

    9. Weber

    7/24/2019

     

     

    10. Wickham

    8/13/2019

     

     

    11. Wood

    10/8/2019

     

     

  13. Route connecting Play Components – Engineered Wood Fiber Surface

    Violation – The cross slope of portions of the route connecting ground level play components and elevated play components exceeds 1:48 (2.08%).

    Requirement – The cross slope of walking surfaces shall not be steeper than 1:48. 2010 Standards §§ 206.2.17.1, 240.2.1, 240.2.2, 402.2, 403.3

    Elementary School(s)

    Completion Date

    Projected Completion

    If not completed, Architectural plans needed? Y/N

    1. Alexander

    10/19/2018

     

     

    2. Borlaug

    7/26/2019

     

     

    3. Coralville Central

    10/25/2018

     

     

    4. Hoover East

    10/19/2018

     

     

    5. Horn

    9/27/2018

     

     

    6. Kirkwood

    10/11/2018

     

     

    7. Lemme

    9/7/2018

     

     

    8. Shimek

    9/12/2018

     

     

    9. Weber

    7/24/2019

     

     

    10. Wickham

    8/13/2019

     

     

    11. Wood

    10/8/2019

     

     

  14. Route connecting Play Components – Engineered Wood Fiber Surface

    Violation – The engineered wood fiber surface is not stable and firm.

    Requirement – Floor and ground surfaces shall be stable, firm, and slip resistant. 2010 Standards §§ 206.2.17, 240.2.1, 240.2.2, 402.2, 403.2, 302.1

    Elementary School(s)

    Completion Date

    Projected Completion

    If not completed, Architectural plans needed? Y/N

    1. Alexander

    10/19/2018

     

     

    2. Borlaug

    7/26/2019

     

     

    3. Coralville Central

    10/25/2018

     

     

    4. Hoover East

    10/19/2018

     

     

    5. Horn

    9/27/2018

     

     

    6. Kirkwood

    10/11/2018

     

     

    7. Lemme

    9/7/2018

     

     

    8. Penn

    8/28/2019

     

     

    9. Shimek

    9/12/2018

     

     

    10. Weber

    7/24/2019

     

     

    11. Wickham

    8/13/2019

     

     

    12. Wood

    10/8/2019

     

     

  15. Route connecting Play Components – Engineered Wood Fiber Surface

    Violation – Changes in level along the undulating engineered wood fiber surface exceed ½ inch.

    Requirement – Changes in level greater than ½ inch high shall be ramped. 2010 Standards §§ 206.2.17.1, 240.2.1, 240.2.2, 402.2, 403.4, 303.4

    Elementary School(s)

    Completion Date

    Projected Completion

    If not completed, Architectural plans needed? Y/N

    1. Alexander

    10/19/2018

     

     

    2. Borlaug

    7/26/2019

     

     

    3. Coralville Central

    10/25/2018

     

     

    4. Hoover East

    10/19/2018

     

     

    5. Horn

    9/27/2018

     

     

    6. Kirkwood

    10/11/2018

     

     

    7. Lemme

    9/7/2018

     

     

    8. Penn

    8/28/2019

     

     

    9. Shimek

    9/12/2018

     

     

    10. Weber

    7/24/2019

     

     

    11. Wickham

    8/13/2019

     

     

    12. Wood

    10/8/2019

     

     

  16. Route connecting Play Components – Engineered Wood Fiber Surface

    Violation – The engineered wood fiber surface is not compacted for the entirety of its installed depth, as required to meet the wheelchair maneuverability requirements in ASTM F 1951-99. The top layer of the engineered wood fiber surface is loose and easily kicked or brushed away. The depth of the non-compacted engineered wood fiber varies from just a few inches to as much as eight inches depending on location. The lack of a fully compacted surface and the loose surface material that occurs during play results in a surface that does not permit an individual in a wheelchair to propel across the surface.

    Requirement – Ground surfaces on accessible routes, clear floor or ground spaces, and turning spaces shall comply with ASTM F 1951 (incorporated by reference, see “Referenced Standards” in Chapter 1). 2010 Standards §§ 206.2.17, 240.2.1, 240.2.1.1, 1008.2.6.1

    Elementary School(s)

    Completion Date

    Projected Completion

    If not completed, Architectural plans needed? Y/N

    1. Alexander

    10/19/2018

     

     

    2. Borlaug

    7/26/2019

     

     

    3. Coralville Central

    10/25/2018

     

     

    4. Hoover East

    10/19/2018

     

     

    5. Horn

    9/27/2018

     

     

    6. Kirkwood

    10/11/2018

     

     

    7. Lemme

    9/7/2018

     

     

    8. Penn

    8/28/2019

     

     

    9. Shimek

    9/12/2018

     

     

    10. Weber

    7/24/2019

     

     

    11. Wickham

    8/13/2019

     

     

    12. Wood

    10/8/2019

     

     

  17. Route connecting Play Components – Engineered Wood Fiber Surface

    Violation – The engineered wood fiber surface contains numerous depressions and loose surface material along the route to play components and within the use zone of play components, such as slide exits and swings. The depth and compaction of the engineered wood fiber surface along the route to play components and within the use zone is not maintained as required to meet the wheelchair maneuverability requirements in ASTM F 1951-99.

    Requirement – Ground surfaces shall be inspected and maintained regularly and frequently to ensure continued compliance with ASTM F 1951. 2010 Standards §§ 206.2.17, 240.2.1, 240.2.1.1, 1008.2.6.1

    Elementary School(s)

    Completion Date

    Projected Completion

    If not completed, Architectural plans needed? Y/N

    1. Alexander

    10/19/2018

     

     

    2. Borlaug

    7/26/2019

     

     

    3. Coralville Central

    10/25/2018

     

     

    4. Hoover East

    10/19/2018

     

     

    5. Horn

    9/27/2018

     

     

    6. Kirkwood

    10/11/2018

     

     

    7. Lemme

    9/7/2018

     

     

    8. Penn

    8/28/2019

     

     

    9. Shimek

    9/12/2018

     

     

    10. Weber

    7/24/2019

     

     

    11. Wickham

    8/13/2019

     

     

    12. Wood

    10/8/2019

     

     

  18. Route connecting Play Components – Engineered Wood Fiber Surface

    Violation – The ground surface within the use zone of the play components is not the minimum depth indicated on supplied play components for impact attenuation in compliance with ASTM F1292.

    Requirement – Ground surfaces located within use zones shall comply with ASTM F 1292 (1999 edition or 2004 edition) (incorporated by reference, see “Referenced Standards” in Chapter 1) 2010 Standards §§ 206.2.17, 240.2.1, 240.2.1.1, 1008.2.6.2

    Elementary School(s)

    Completion Date

    Projected Completion

    If not completed, Architectural plans needed? Y/N

    1. Horn

    9/27/2018

     

     

  19. Route connecting Play Components – Rubber Tile Surface

    Violation – Changes in level between some adjacent rubber tiles exceed ½ inch.

    Requirement – Changes in level greater than ½ inch high shall be ramped. 2010 Standards §§ 206.2.17.1, 240.2.1, 240.2.2, 402.2, 403.4, 303.4

    Elementary School(s)

    Completion Date

    Projected Completion

    If not completed, Architectural plans needed? Y/N

    1. Weber

    10/1/2019

     

     

    2. Wickham

     

    12/1/2020

    No

    3. Wood

     

    12/1/2020

    No

  20. Route connecting Play Components – Rubber Tile Surface

    Violation – The gap between some adjacent rubber tiles exceeds ½ inch.

    Requirement – Openings in floor or ground surfaces shall not allow passage of a sphere more than ½ inch diameter. 2010 Standards §§ 206.2.17.1, 240.2.1, 240.2.2, 402.2, 403.2, 302.3

    Elementary School(s)

    Completion Date

    Projected Completion

    If not completed, Architectural plans needed? Y/N

    1. Weber

    10/1/2019

     

     

  21. Route connecting Play Components – Wear Mats

    Violation – The slope of the transition between wear mats and transfer platforms and the engineered wood fiber play surface exceeds 1:16.

    Requirement – Ramp runs connecting ground level play components shall have a running slope not steeper than 1:16. 2010 Standards §§ 206.2.17.1, 240.2.1, 240.2.2, 1008.2.5.1

    Elementary School(s)

    Completion Date

    Projected Completion

    If not completed, Architectural plans needed? Y/N

    1. Wickham

     

    12/1/2022

    No

  22. Play Components – Ground Level Play Components

    Violation – The turning space at ground level play components is not level.

    Requirement – At least one of each type of ground level play component and additional ground level play components as required by Table 240.2.1.2 shall have a turning space on the same level as the play component. Changes in level in the clear ground space are not permitted. Slopes in the clear ground space shall not be steeper than 1:48. Where swings are provided, the turning space shall be located immediately adjacent to the swing. 2010 Standards §§ 240.2.1.1, 240.2.1.2, 1008.4.1, 302, 304.2, 304.3

    Elementary School(s)

    Completion Date

    Projected Completion

    If not completed, Architectural plans needed? Y/N

    1. Alexander

    10/19/2018

     

     

    2. Borlaug

    7/26/2019

     

     

    3. Coralville Central

    10/25/2018

     

     

    4. Hoover East

    10/19/2018

     

     

    5. Horn

    9/27/2018

     

     

    6. Kirkwood

    10/11/2018

     

     

    7. Lemme

    9/7/2018

     

     

    8. Penn

    8/28/2019

     

     

    9. Shimek

    9/12/2018

     

     

    10. Weber

    7/24/2019

     

     

    11. Wickham

    8/13/2019

     

     

    12. Wood

    10/8/2019

     

     

  23. Play Components – Ground Level Play Components

    Violation – The clear ground space at ground level play components is not level.

    Requirement – At least one of each type of ground level play component and additional ground level play components as required by Table 240.2.1.2 shall have a clear ground space, 30 inches minimum by 48 inches minimum. Changes in level in the clear ground space are not permitted. Slopes in the clear ground space shall not be steeper than 1:48. 2010 Standards §§ 240.2.1.1, 240.2.1.2, 1008.4.2, 305.2, 305.3

    Elementary School(s)

    Completion Date

    Projected Completion

    If not completed, Architectural plans needed? Y/N

    1. Alexander

    10/19/2018

     

     

    2. Borlaug

    7/26/2019

     

     

    3. Coralville Central

    10/25/2018

     

     

    4. Hoover East

    10/19/2018

     

     

    5. Horn

    9/27/2018

     

     

    6. Kirkwood

    10/11/2018

     

     

    7. Lemme

    9/7/2018

     

     

    8. Penn

    8/28/2019

     

     

    9. Shimek

    9/12/2018

     

     

    10. Weber

    7/24/2019

     

     

    11. Wickham

    8/13/2019

     

     

    12. Wood

    10/8/2019

     

     

  24. Play Components – Elevated Play Components

    Violation – The clear ground space at transfer platforms is not level.

    Requirement – A transfer space, 30 inches minimum by 48 inches minimum, shall be provided adjacent to the transfer platform. Changes in level in the clear ground space are not permitted. Slopes in the clear ground space shall not be steeper than 1:48. 2010 Standards §§ 206.2.17, 240.2.2, 1008.2.1 1008.3.1.3, 305.2, 305.3

    Elementary School(s)

    Completion Date

    Projected Completion

    If not completed, Architectural plans needed? Y/N

    1. Alexander

    10/19/2018

     

     

    2. Borlaug

    7/26/2019

     

     

    3. Coralville Central

    10/25/2018

     

     

    4. Hoover East

    10/19/2018

     

     

    5. Horn

    9/27/2018

     

     

    6. Kirkwood

    10/11/2018

     

     

    7. Lemme

    9/7/2018

     

     

    8. Penn

    8/28/2019

     

     

    9. Shimek

    9/12/2018

     

     

    10. Weber

    7/24/2019

     

     

    11. Wickham

    8/13/2019

     

     

    12. Wood

    10/8/2019

     

     

  25. Play Components – Elevated Play Components

    Violation – The height of transfer platforms is either less than 11 inches or more than 18 inches.

    Requirement – The height of transfer platforms shall be 11 inches minimum and 18 inches maximum measured to the top of the surface from the ground surface. 2010 Standards §§ 206.2.17, 240.2.2, 1008.3.1.2

    Elementary School(s)

    Completion Date

    Projected Completion

    If not completed, Architectural plans needed? Y/N

    1. Alexander

    10/19/2018

     

     

    2. Borlaug

    7/26/2019

     

     

    3. Coralville Central

    10/25/2018

     

     

    4. Hoover East

    10/19/2018

     

     

    5. Horn

    9/27/2018

     

     

    6. Lemme

    9/7/2018

     

     

    7. Penn

    8/28/2019

     

     

    8. Shimek

    9/12/2018

     

     

    9. Wood

    10/8/2019

     

     

  26. Play Area Amenities – Benches

    Violation – A clear ground space adjacent to a bench at the play area is not provided.

    Requirement – A clear ground space 30 inches minimum by 48 inches minimum shall be provided. 28 C.F.R § 35.150, 2010 Standards § 305.3

    Elementary School(s)

    Completion Date

    Projected Completion

    If not completed, Architectural plans needed? Y/N

    1. Borlaug

     

    12/1/2020

    No

    2. Shimek

    11/30/2017

     

     

    3. Weber

    10/1/2019

     

     

    4. Wickham

     

    12/1/2022

    No

  27. Play Area Amenities – Benches

    Violation – The surface of the route to benches is non-compacted engineered wood fiber or grass.

    Requirement – At least one accessible route shall connect accessible buildings, accessible facilities, accessible elements, and accessible spaces that are on the same site. Floor and ground surfaces shall be stable, firm, and slip resistant. 2010 Standards §§ 206.2.2, 402.2, 403.2, 302.1

    Elementary School(s)

    Completion Date

    Projected Completion

    If not completed, Architectural plans needed? Y/N

    1. Lemme

     

    12/1/2022

    No

    2. Shimek

    11/30/2017

     

     

    3. Weber

    10/1/2019

     

     

    4. Wickham

     

    12/1/2022

    No

  28. Play Area Amenities – Benches

    Violation – The clear ground space adjacent to the bench is less than 48 inches deep.

    Requirement – A clear ground space 30 inches minimum by 48 inches minimum shall be provided. One full unobstructed side of the clear floor or ground space shall adjoin an accessible route or adjoin another clear floor or ground space. 28 C.F.R § 35.150, 2010 Standards §§ 305.3, 305.6

    Elementary School(s)

    Completion Date

    Projected Completion

    If not completed, Architectural plans needed? Y/N

    1. Kirkwood

     

    12/1/2020

    No

  29. Play Area Amenities – Picnic Table

    Violation – The surface of the route to the picnic tables is non-compacted engineered wood fiber or grass.

    Requirement – At least one accessible route shall connect accessible buildings, accessible facilities, accessible elements, and accessible spaces that are on the same site. Floor and ground surfaces shall be stable, firm, and slip resistant. 2010 Standards §§ 206.2.2, 402.2, 403.2, 302.1

    Elementary School(s)

    Completion Date

    Projected Completion

    If not completed, Architectural plans needed? Y/N

    1. Coralville Central

    12/1/2018

     

     

    2. Horn

     

    12/1/2022

    No

    3. Shimek

    11/30/2017

     

     

    4. Weber

    10/1/2019

     

     

    5. Wickham

     

    12/1/2022

    No

  30. Play Area Amenities – Picnic Table

    Violation – No wheelchair spaces are provided at the picnic table.

    Requirement – Where dining surfaces are provided for the consumption of food or drink, at least 5 percent of the seating spaces at the dining surfaces shall provide clear floor space, knee and toe clearance, and a dining surface 28 inches minimum and 34 inches maximum. 2010 Standards §§ 226.1, 902.1, 902.2, 902.3, 305, 306

    Elementary School(s)

    Completion Date

    Projected Completion

    If not completed, Architectural plans needed? Y/N

    1. Alexander

    2018

     

     

    2. Borlaug

    2019

     

     

    3. Coralville Central

    2019

     

     

    4. Horn

    2019

     

     

    5. Shimek

    11/30/2017

     

     

    6. Weber

    10/1/2019

     

     

    7. Wickham

    2019

     

     