SETTLEMENT AGREEMENT BETWEEN
THE UNITED STATES OF AMERICA
AND
HAWAII DEPARTMENT OF PUBLIC SAFETY

APPENDIX B

No.

Location

2010 Standards Citations

Violations

Requirement/Action Required

Completion Date

1

Olomana Cottage

Visitor Toilet Room

206.4, 206.5, 309.4, 404.2.7

There is no door hardware on the exterior of the toilet room door.

Provide a door with hardware, mounted between 34 and 48 inches high, that is operable with one hand and does not require tight grasping, pinching, or twisting of the wrist and requires no more than 5 pounds of force to operate. Lever-operated mechanisms, push-type mechinisms, and U-shaped handles are acceptable designs.

6 months

2

213.3.4, 306, 606.2, 606.3

The apron of the lavatory is 26 1/2 inches above the finished floor.

Provide a lavatory with the top of the rim or counter 34 inches high or less; knee clearance at least 30 inches wide, between 9 inches and 27 inches high, extending between 11 and 25 inches deep at 9 inches high, and extending at least 8 inches deep at 27 inches high; and toe clearance at least 30 inches wide and 9 inches high, and extending between 17 and 25 inches deep under the lavatory.

36 months

3

213.3.4, 606.3, 606.4,

The lavatory pipes are not covered or otherwise designed to protect against contact.

Provide a lavatory with the water and supply drain pipes are insulated or otherwise configured to protect against contact.

6 months

4

213.3.5, 603.3

The reflective surface of the mirror is mounted 42 inches above the floor.

Provide a mirror with the bottom edge of its reflectivg surface no more than 40 inches above the finished floor.

3 months

5

205.1, 305, 308.2, 308.3

The soap dispenser is mounted 63 inches above the finished foor with a 16 inch reach over the lavatory.

Operable parts and controls of this element shall be no more than 44 inches high if over an obstruction between 20 and 25 inches deep (for a forward reach, obstructions may not be deeper than 25 inches and obstructions must allow knee space); or mounted not more than 48 inches high for a side reach, or no more than 46 inches high if over an obstruction between 10 and 24 inches deep (for a side reach, obstruction may not be deeper than 24 inches); and accompanied by clear floor space of 30 inches by 48 inches that allows a forward or parallel approach, respectively, by a person using a wheelchair.

3 months

6

205.1, 305, 308.2, 308.3

The toilet seat cover dispenser is mounted 59 inches above the floor and is obstructed by the toilet.

Operable parts and controls of this element shall be no more than 48 inches high for a forward reach, or no more than 44 inches high if over an obstruction between 20 and 25 inches deep (for a forward reach, obstructions may not be deeper than 25 inches and obstructions must allow knee space); or mounted not more than 48 inches high for a side reach, or no more than 46 inches high if over an obstruction between 10 and 24 inches deep (for a side reach, obstruction may not be deeper than 24 inches); and accompanied by clear floor space of 30 inches by 48 inches that allows a forward or parallel approach, respectively, by a person using a wheelchair.

6 months

7

213.3.2, 604.7, 609.3

The toilet paper dispenser is located 5 inches in front of the water closet.

Provide a toilet paper dispenser that is mounted with its centerline between 7 and 9 inches from the front of the toilet and with its outlet between 15 and 48 inches high with continuous paper flow that does not control delivery.  The dispenser shall be mounted either at least 1½ inches below the side grab bar or at least 12 inches above the side grab bar. 

6 months

8

Olomana CottageOlomana C

Administrative Segregation
(Cell 7):

213.3.4, 306, 606.2, 606.3

The apron of the lavatory is 26 inches above the finished floor.

Provide a lavatory with the top of the rim or counter 34 inches high or less; knee clearance at least 30 inches wide, between 9 inches and 27 inches high, extending between 11 and 25 inches deep at 9 inches high, and extending at least 8 inches deep at 27 inches high; and toe clearance at least 30 inches wide and 9 inches high, and extending between 17 and 25 inches deep under the lavatory.

36 months

9

213.3.5, 603.3

The reflective surface of the mirror is mounted 41 inches above the floor.

Provide a mirror with the bottom edge of its reflectivg surface no more than 40 inches above the finished floor.

3 months

10

226, 305, 306, 902

The desk has a clear space width of 22 1/2 inches.

Provide a desk with clear floor space 30 inches wide by 48 inches deep positioned for a forward approach; with toe clearance extended 17 inches minimum under the element; with knee clearance at least 11 inches deep at 9 inches high and at least 8 inches deep at 27 inches high; and with a dining or work surface between 28 inches and 34 inches high.  They shall be distributed throughout the facility, if applicable.

24 months

11

Olomana CottageOlomana C

Detention (Cell 8)

28 C.F.R. §35.151(k), 232, 807.

There is less than 3% of the total number of accessible cells provided in Ward A.

For new and altered facilities, the prison shall provide a minimum of 3% accessible cells, but no fewer than one, of the total number of cells in Administrative Segregation.  To be accessible, all of the cells' elements, including door, clear floor space, water closet, grab bars, lavatory, mirror, bed, desk, controls, and dispensers comply with the ADA Standards. 

36 months

12

206.5, 213.2, 213.3.6, 404, 603, 608

There is no accessible shower.

Provide a transfer shower that is exactly 36 inches wide and 36 inches deep with a 48 inch long and 36 inch wide clear floor space alongside the shower opening, and an L-shaped shower seat mounted on the wall opposite the controls and extending the full depth of the stall; OR a shower that is at least 30 inches deep and 60 inches wide with no curb or threshold and with a 36 inch deep and 60 inch wide clear floor space at the shower opening.  Ensure that the shower has grab bars, controls, a shower spray unit, and a seat, curb, and enclosure, if provided, that comply fully with the Standards.

36 months

13

Olomana CottageOlomana C

Maximum Security

28 C.F.R. §35.151(k), 232, 807.

There is less than 3% of the total number of accessible cells provided in Ward A.

For new and altered facilities, the prison shall provide a minimum of 3% accessible cells, but no fewer than one, of the total number of cells in Administrative Segregation.  To be accessible, all of the cells' elements, including door, clear floor space, water closet, grab bars, lavatory, mirror, bed, desk, controls, and dispensers comply with the ADA Standards. 

36 months

14

2.13.3.6, 608.2.1, 610

The shower compartment is 37 1/2 inches by 38 inches and there is only 11 inches of  transfer space on the  side opposite the controls.

The shower compartment shall be 36 inches by 36 inches, the entrance shall be at least 36 inches wide, and clearance adjacent to the opening shall be 36 inches wide by 48 inches long measured from the control wall (so that the clearance extends beyond the seat).

36 months

15

213.3.6, 608.6

There is no compliant lower accessible spray nozzle and no shower hose provided.

Provide a shower spray unit with a hose at least 59 inches long that can be used both as a fixed shower head and as a hand-held shower, with an on/off control with a non-positive shutoff, that delivers water no hotter than 120 degrees.  In facilities that are not medical care facilities, long-term care facilities, transient lodging guest rooms, or residential dwelling units, a fixed shower head mounted at 48 inches above the shower floor may be used in lieu of a hand-held shower head. 

36 months

16

213.3.6, 610.3

There is no fixed shower seat provided.

In transfer type shower compartments, provide a seat mounted between 17 and 19 inches high on the wall opposite the controls extending from within 1½ inches of the back wall to within 3 inches of the compartment entry.  If the seat is rectangular, it should extend from 2½ inches to between 15 and 16 inches from the wall on which it is mounted.  If the seat is L-shaped, the portion near the compartment entry should extend from 2½ inches to between 15 and 16 inches from the wall on which it is mounted, and the portion near the back wall should extend between 14 and 15 inches from the back wall and between 22 and 23 inches from the wall on which it is mounted.

36 months

17

Olomana CottageRoute between Olomana C and A

206, 307

Both drinking fountains protrude into the accessible walkway.

Unless protected by a cane detectable barrier, objects with their leading edges between 27 inches and 80 inches high shall not protrude into circulation paths more than 4 inches for wall-mounted elements, or 12 inches for free standing post- or pylon-mounted elements.  Protruding objects (and cane-detectable barriers) shall not reduce the clear width of accessible routes or maneuvering spaces below minimum requirements.

12 months

18

Olomana CottageOlomana A

Bathroom

604.8.1.2

The toilet compartment door is 31.5 inches wide.

Provide a self-closing compartment door at least 32 inches wide either in the front partition or side partition farthest from the toilet.

36 months

19

213.3.2, 604.2

The centerline of the toilet is 15 inches from the side wall.

Provide a toilet with its centerline between 16 and 18 inches from the near side wall.

36 months

20

213.3.2, 604.7, 609.3

The toilet paper dispenser is 15 inches in front of the front edge of the toilet.

Provide a toilet paper dispenser that is mounted with its centerline between 7 and 9 inches from the front of the toilet and with its outlet between 15 and 48 inches high with continuous paper flow that does not control delivery.  The dispenser shall be mounted either at least 1½ inches below the side grab bar or at least 12 inches above the side grab bar.

6 months

21

213.3.5, 603.3

The reflective surface of the mirror is mounted 41 inches above the floor.

Provide a mirror with the bottom edge of its reflectivg surface no more than 40 inches above the finished floor.

3 months

22

2.13.3.6, 608.2.1, 610

The shower compartment is 37 inches by 37 inches.

The shower compartment shall be 36 inches by 36 inches, the entrance shall be at least 36 inches wide, and clearance adjacent to the opening shall be 36 inches wide by 48 inches long measured from the control wall (so that the clearance extends beyond the seat).

36 months

23

213.3.6, 608.6

The lower spray nozzle is 61 inches above the floor and there is no shower hose provided.

Provide a shower spray unit with a hose at least 59 inches long that can be used both as a fixed shower head and as a hand-held shower, with an on/off control with a non-positive shutoff, that delivers water no hotter than 120 degrees.  In facilities that are not medical care facilities, long-term care facilities, transient lodging guest rooms, or residential dwelling units, a fixed shower head mounted at 48 inches above the shower floor may be used in lieu of a hand-held shower head. 

36 months

24

Olomana CottageOlomana A

Mailbox

206, 307

The mailbox protrudes into the accessible walkway.

Unless protected by a cane detectable barrier, objects with their leading edges between 27 inches and 80 inches high shall not protrude into circulation paths more than 4 inches for wall-mounted elements, or 12 inches for free standing post- or pylon-mounted elements.  Protruding objects (and cane-detectable barriers) shall not reduce the clear width of accessible routes or maneuvering spaces below minimum requirements.

3 months

25

Olomana CottageOlomana A

Dining Hall

226, 305, 306, 902

No accessible tables.

At least 5% (but no fewer than 1) of dining or work surfaces shall be available for use by people with mobility disabilities.  Each accessible dining or work surface shall be on an accessible route; with clear floor space 30 inches wide by 48 inches deep positioned for a forward approach; with toe clearance extended 17 inches minimum under the element; with knee clearance at least 11 inches deep at 9 inches high and at least 8 inches deep at 27 inches high; and with a dining or work surface between 28 inches and 34 inches high.  They shall be distributed throughout the facility, if applicable.

6 months

26

Olomana CottageOlomana A

Visors Room

206.5, 302, 303, 404.2.5

There is a 1 inch threshold at the entry door.

Provide an accessible door with a threshold that is no more than ¼ inch high, or is between ¼ inch and ½ inch high (¾ inch high if the threshold is existing or altered) and is beveled with a slope no greater than 50%.

12 months

27

Olomana CottageOlomana A

Visitor's Toilet Room - Women

213.3.4, 306, 606.2, 606.3

The apron of the lavatory is 25 1/2 inches above the finished floor.

Provide a lavatory with the top of the rim or counter 34 inches high or less; knee clearance at least 30 inches wide, between 9 inches and 27 inches high, extending between 11 and 25 inches deep at 9 inches high, and extending at least 8 inches deep at 27 inches high; and toe clearance at least 30 inches wide and 9 inches high, and extending between 17 and 25 inches deep under the lavatory.

36 months

28

213.3.4, 606.3, 606.4,

The lavatory pipes are not covered or otherwise designed to protect against contact.

Provide a lavatory with the water and supply drain pipes are insulated or otherwise configured to protect against contact.

6 months

29

213.3.5, 603.3

The reflective surface of the mirror is mounted 41 inches above the floor.

Provide a mirror with the bottom edge of its reflectivg surface no more than 40 inches above the finished floor.

3 months

30

205.1, 305, 308.2, 308.3

The soap dispenser is mounted more than 48 inches above the finished foor.

Operable parts and controls of this element shall be no more than 48 inches high for a forward reach, or no more than 44 inches high if over an obstruction between 20 and 25 inches deep (for a forward reach, obstructions may not be deeper than 25 inches and obstructions must allow knee space); or mounted not more than 48 inches high for a side reach, or no more than 46 inches high if over an obstruction between 10 and 24 inches deep (for a side reach, obstruction may not be deeper than 24 inches); and accompanied by clear floor space of 30 inches by 48 inches that allows a forward or parallel approach, respectively, by a person using a wheelchair.

3 months

31

213.3.2, 604.7, 609.3

The toilet paper dispenser is 12 inches in front of the front edge of the toilet.

Provide a toilet paper dispenser that is mounted with its centerline between 7 and 9 inches from the front of the toilet and with its outlet between 15 and 48 inches high with continuous paper flow that does not control delivery.  The dispenser shall be mounted either at least 1½ inches below the side grab bar or at least 12 inches above the side grab bar.

6 months

32

213.3.2, 604.5.1

The side grab bar is mounted 13 inches from the rear wall.

Provide a side grab bar that is at least 42 inches in overall length, with the far end mounted at least 54 inches from the rear wall, and with the closer end no more than 12 inches from the rear wall.

6 months

33

Olomana CottageOlomana A

Staff Only/Visitor Toilet Room - Men

213.3.4, 306, 606.2, 606.3

The apron of the lavatory is 25 1/2 inches above the finished floor.

Provide a lavatory with the top of the rim or counter 34 inches high or less; knee clearance at least 30 inches wide, between 9 inches and 27 inches high, extending between 11 and 25 inches deep at 9 inches high, and extending at least 8 inches deep at 27 inches high; and toe clearance at least 30 inches wide and 9 inches high, and extending between 17 and 25 inches deep under the lavatory.

36 months

34

213.3.4, 606.3, 606.4,

The pipes are not covered or otherwise designed to protect against contact.

Provide a lavatory with the water and supply drain pipes are insulated or otherwise configured to protect against contact.

6 months

35

213.3.5, 603.3

The reflective surface of the mirror is mounted 41 inches above the floor.

Provide a mirror with the bottom edge of its reflectivg surface no more than 40 inches above the finished floor.

3 months

36

205.1, 305, 308.2, 308.3

The soap dispenser is mounted more than 48 inches above the finished foor.

Operable parts and controls of this element shall be no more than 48 inches high for a forward reach, or no more than 44 inches high if over an obstruction between 20 and 25 inches deep (for a forward reach, obstructions may not be deeper than 25 inches and obstructions must allow knee space); or mounted not more than 48 inches high for a side reach, or no more than 46 inches high if over an obstruction between 10 and 24 inches deep (for a side reach, obstruction may not be deeper than 24 inches); and accompanied by clear floor space of 30 inches by 48 inches that allows a forward or parallel approach, respectively, by a person using a wheelchair.

3 months

37

205.1, 305, 308.2, 308.3

The paper towel dispenser is mounted 62 inches above the finished floor.

Operable parts and controls of this element shall be no more than 48 inches high for a forward reach, or no more than 44 inches high if over an obstruction between 20 and 25 inches deep (for a forward reach, obstructions may not be deeper than 25 inches and obstructions must allow knee space); or mounted not more than 48 inches high for a side reach, or no more than 46 inches high if over an obstruction between 10 and 24 inches deep (for a side reach, obstruction may not be deeper than 24 inches); and accompanied by clear floor space of 30 inches by 48 inches that allows a forward or parallel approach, respectively, by a person using a wheelchair.

6 months

38

213.3.2, 604.5.1

The side grab bar is mounted 13 inches from the rear wall.

Provide a side grab bar that is at least 42 inches in overall length, with the far end mounted at least 54 inches from the rear wall, and with the closer end no more than 12 inches from the rear wall.

6 months

39

205.1, 305, 308.2, 308.3

Toilet seat cover dispenser is mounted 55 inches above the finished floor.

Operable parts and controls of this element shall be no more than 48 inches high for a forward reach, or no more than 44 inches high if over an obstruction between 20 and 25 inches deep (for a forward reach, obstructions may not be deeper than 25 inches and obstructions must allow knee space); or mounted not more than 48 inches high for a side reach, or no more than 46 inches high if over an obstruction between 10 and 24 inches deep (for a side reach, obstruction may not be deeper than 24 inches); and accompanied by clear floor space of 30 inches by 48 inches that allows a forward or parallel approach, respectively, by a person using a wheelchair.

6 months

40

Maunawili Cottage

Inmate Outdoor Toilet Rooms

213.3.4, 606.3, 606.4,

The pipes are not covered or otherwise designed to protect against contact.

Provide a lavatory with the water and supply drain pipes are insulated or otherwise configured to protect against contact.

6 months

41

205.1, 305, 308.2, 308.3

The soap dispenser is mounted 58 inches above the finished foor.

Operable parts and controls of this element shall be no more than 48 inches high for a forward reach, or no more than 44 inches high if over an obstruction between 20 and 25 inches deep (for a forward reach, obstructions may not be deeper than 25 inches and obstructions must allow knee space); or mounted not more than 48 inches high for a side reach, or no more than 46 inches high if over an obstruction between 10 and 24 inches deep (for a side reach, obstruction may not be deeper than 24 inches); and accompanied by clear floor space of 30 inches by 48 inches that allows a forward or parallel approach, respectively, by a person using a wheelchair.

3 months

42

28 C.F.R. § 35.133

Lavatory faucet controls are not maintained in operable condition.

Maintain this feature in operable working condition.

6 months

43

Maunawili Cottage

Medical Unit
Toilet Room

213.3.5, 603.3

The reflective surface of the mirror is mounted 41 inches above the floor.

Provide a mirror with the bottom edge of its reflectivg surface no more than 40 inches above the finished floor.

3 months

44

205.1, 305, 308.2, 308.3

The soap dispenser is mounted 57 inches above the finished foor.

Operable parts and controls of this element shall be no more than 48 inches high for a forward reach, or no more than 44 inches high if over an obstruction between 20 and 25 inches deep (for a forward reach, obstructions may not be deeper than 25 inches and obstructions must allow knee space); or mounted not more than 48 inches high for a side reach, or no more than 46 inches high if over an obstruction between 10 and 24 inches deep (for a side reach, obstruction may not be deeper than 24 inches); and accompanied by clear floor space of 30 inches by 48 inches that allows a forward or parallel approach, respectively, by a person using a wheelchair.

3 months

45

205.1, 305, 308.2, 308.3

The paper towel dispenser is mounted 50 inches above the finished floor, behind the toilet.

Operable parts and controls of this element shall be no more than 48 inches high for a forward reach, or no more than 44 inches high if over an obstruction between 20 and 25 inches deep (for a forward reach, obstructions may not be deeper than 25 inches and obstructions must allow knee space); or mounted not more than 48 inches high for a side reach, or no more than 46 inches high if over an obstruction between 10 and 24 inches deep (for a side reach, obstruction may not be deeper than 24 inches); and accompanied by clear floor space of 30 inches by 48 inches that allows a forward or parallel approach, respectively, by a person using a wheelchair.

3 months

46

213.3.4, 606.3, 606.4,

The pipes are not covered or otherwise designed to protect against contact.

Provide a lavatory with the water and supply drain pipes are insulated or otherwise configured to protect against contact.

6 months

47

213.3.2, 604.3.

There is insufficient clearance at the toilet.

Provide clearance at the toilet that is at least 60 inches wide and 56 inches deep.  This clearance may overlap with the toilet, grab bars, dispensers, sanitary napkin disposal, coat hooks, shelves, accessible routes, clear floor space and clearances for other fixtures, and turning space; but no other fixtures or obstructions, including lavatories, may be located within this clearance.

36 months

48

213.3.2, 604.5.2

The rear grab bar is 24 inches long.

Provide a rear grab bar that is at least 36 inches long (except where wall space does not permit it due to the location of a recessed fixture, in which case the grab bar may be 24 inches long and centered on the toilet), extending 12 inches from the toilet centerline on one side and 24 inches from the toilet centerline on the other side (except where an administrative authority requires flush controls to be located in a position that conflicts with the location of the rear grab bar, in which case the bar may be split or shifted to the open side).

6 months

49

Maunawili Cottage

Medical Ward

205.1, 305, 308.2, 308.3

The soap dispenser is mounted more than 52 inches above the finished foor.

Operable parts and controls of this element shall be no more than 48 inches high for a forward reach, or no more than 44 inches high if over an obstruction between 20 and 25 inches deep (for a forward reach, obstructions may not be deeper than 25 inches and obstructions must allow knee space); or mounted not more than 48 inches high for a side reach, or no more than 46 inches high if over an obstruction between 10 and 24 inches deep (for a side reach, obstruction may not be deeper than 24 inches); and accompanied by clear floor space of 30 inches by 48 inches that allows a forward or parallel approach, respectively, by a person using a wheelchair.

3 months

50

213.3.4, 606.3, 606.4,

The pipes are not covered or otherwise designed to protect against contact.

Provide a lavatory with the water and supply drain pipes are insulated or otherwise configured to protect against contact.

6 months

51

28 C.F.R. § 35.133

Lavatory faucet controls are not maintained in operable condition.

Maintain this feature in operable working condition.

6 months

52

213.3.2, 309.4, 604.6

The flush control is mounted on the closed side of the toilet.

Provide a flush control mounted on the “open” side of the toilet’s clear floor space, between 15 and 48 inches high, and requiring a maximum of 5 pounds of force to operate; or provide an automatic flush device.

9 months

53

Maunawili CottageTub/Toilet/Shower Room across from Infirmary Cell 5

213.3.5, 603.3

The reflective surface of the mirror is mounted 41 inches above the floor.

Provide a mirror with the bottom edge of its reflectivg surface no more than 40 inches above the finished floor.

3 months

54

205.1, 305, 308.2, 308.3

The soap dispenser is mounted 60 1/2 inches above the finished foor.

Operable parts and controls of this element shall be no more than 48 inches high for a forward reach, or no more than 44 inches high if over an obstruction between 20 and 25 inches deep (for a forward reach, obstructions may not be deeper than 25 inches and obstructions must allow knee space); or mounted not more than 48 inches high for a side reach, or no more than 46 inches high if over an obstruction between 10 and 24 inches deep (for a side reach, obstruction may not be deeper than 24 inches); and accompanied by clear floor space of 30 inches by 48 inches that allows a forward or parallel approach, respectively, by a person using a wheelchair.

6 months

55

213.3.4, 606.3, 606.4,

The pipes are not covered or otherwise designed to protect against contact.

Provide a lavatory with the water and supply drain pipes are insulated or otherwise configured to protect against contact.

6 months

56

205.1, 305, 308.2, 308.3

The paper towel dispenser is mounted 53 inches above the finished floor, behind the toilet.

Operable parts and controls of this element shall be no more than 48 inches high for a forward reach, or no more than 44 inches high if over an obstruction between 20 and 25 inches deep (for a forward reach, obstructions may not be deeper than 25 inches and obstructions must allow knee space); or mounted not more than 48 inches high for a side reach, or no more than 46 inches high if over an obstruction between 10 and 24 inches deep (for a side reach, obstruction may not be deeper than 24 inches); and accompanied by clear floor space of 30 inches by 48 inches that allows a forward or parallel approach, respectively, by a person using a wheelchair.

6 months

57

213.3.2, 604.7, 609.3

The toilet paper dispenser is 5 inches in front of the front edge of the toilet.

Provide a toilet paper dispenser that is mounted with its centerline between 7 and 9 inches from the front of the toilet and with its outlet between 15 and 48 inches high with continuous paper flow that does not control delivery.  The dispenser shall be mounted either at least 1½ inches below the side grab bar or at least 12 inches above the side grab bar.

6 months

58

213.3.2, 309.4, 604.6

The flush control is mounted on the closed side of the toilet.

Provide a flush control mounted on the “open” side of the toilet’s clear floor space, between 15 and 48 inches high, and requiring a maximum of 5 pounds of force to operate; or provide an automatic flush device.

9 months

59

213.3.6, 610.3

There is no fixed shower seat provided.

In transfer type shower compartments, provide a seat mounted between 17 and 19 inches high on the wall opposite the controls extending from within 1½ inches of the back wall to within 3 inches of the compartment entry.  If the seat is rectangular, it should extend from 2½ inches to between 15 and 16 inches from the wall on which it is mounted.  If the seat is L-shaped, the portion near the compartment entry should extend from 2½ inches to between 15 and 16 inches from the wall on which it is mounted, and the portion near the back wall should extend between 14 and 15 inches from the back wall and between 22 and 23 inches from the wall on which it is mounted.

12 months

60

213.3.6, 610.3

No shower spray unit or fixed lower shower head is provided.

In transfer type shower compartments, provide a seat mounted between 17 and 19 inches high on the wall opposite the controls extending from within 1½ inches of the back wall to within 3 inches of the compartment entry.  If the seat is rectangular, it should extend from 2½ inches to between 15 and 16 inches from the wall on which it is mounted.  If the seat is L-shaped, the portion near the compartment entry should extend from 2½ inches to between 15 and 16 inches from the wall on which it is mounted, and the portion near the back wall should extend between 14 and 15 inches from the back wall and between 22 and 23 inches from the wall on which it is mounted.

12 months

61

Maunawili Cottage

Education Center

Classroom 2

226, 305, 306, 902

The desks have 24 1/2 inches of knee space.

At least 5% (but no fewer than 1) of dining or work surfaces shall be available for use by people with mobility disabilities.  Each accessible dining or work surface shall be on an accessible route; with clear floor space 30 inches wide by 48 inches deep positioned for a forward approach; with toe clearance extended 17 inches minimum under the element; with knee clearance at least 11 inches deep at 9 inches high and at least 8 inches deep at 27 inches high; and with a dining or work surface between 28 inches and 34 inches high.  They shall be distributed throughout the facility, if applicable.

6 months

62

Maunawili Cottage

Education Center
Law Library

206, 403.5.1

The route between the library shelves is 34 inches wide.

Provide to each area, feature, or element described an accessible route with a minimum clear width of 36 inches, except that the width may decrease to 32 inches for a depth of no more than 24 inches.

12 months

63

226, 305, 306, 902

The desks have 24 1/2 inches of knee space.

At least 5% (but no fewer than 1) of work surfaces shall be available for use by people with mobility disabilities.  Each accessible work surface shall be on an accessible route; with clear floor space 30 inches wide by 48 inches deep positioned for a forward approach; with toe clearance extended 17 inches minimum under the element; with knee clearance at least 11 inches deep at 9 inches high and at least 8 inches deep at 27 inches high; and with a work surface between 28 inches and 34 inches high.  They shall be distributed throughout the facility, if applicable.

24 months

64

Maunawili Cottage
Intake
Holding Cell 1

213.3.2, 604.2

The centerline of the toilet is 19 inches from the side wall.

Provide a toilet with its centerline between 16 and 18 inches from the near side wall.

36 months

65

222.1, 305, 803.4, 903

The seat of the bench is 16 inches above the finished floor and 19 inches deep.

Provide a bench with a seat at least 42 inches long and between 20 and 24 inches deep that is either affixed to a wall or has a back support that is at least 42 inches long, is no more than 2½ inches horizontally from the rear edge of the seat, and extends from no more than 2 inches to at least 18 inches above the seat.  The top of the seat shall be between 17 and 19 inches high and shall provide clear floor space at the end of the bench parallel to the bench’s short axis.

36 months

66

Ahiki Cottage

Designated Accessible Toilet Room/Strip Search/Common Area

213.3.2, 604.4

The toilet seat is 15 inches above the floor.

Provide a toilet with the top of the seat 17 to 19 inches high.  The seat shall not be sprung to return to a lifted position.

36 months

67

28 C.F.R. § 35.133

The paper towel dispenser is empty.

Maintain this feature in operable working condition.

3 months

68

205.1, 305, 308.2, 308.3

The soap dispenser is mounted more than 60 inches above the finished foor.

Operable parts and controls of this element shall be no more than 48 inches high for a forward reach, or no more than 44 inches high if over an obstruction between 20 and 25 inches deep (for a forward reach, obstructions may not be deeper than 25 inches and obstructions must allow knee space); or mounted not more than 48 inches high for a side reach, or no more than 46 inches high if over an obstruction between 10 and 24 inches deep (for a side reach, obstruction may not be deeper than 24 inches); and accompanied by clear floor space of 30 inches by 48 inches that allows a forward or parallel approach, respectively, by a person using a wheelchair.

6 months

69

Ahiki Cottage

Ahiki A

Designated Accessible
Inmate Dorm

226, 305, 306, 902

The desk has a clear space width of 17 inches.

At least 5% (but no fewer than 1) of dining or work surfaces shall be available for use by people with mobility disabilities.  Each accessible dining or work surface shall be on an accessible route; with clear floor space 30 inches wide by 48 inches deep positioned for a forward approach; with toe clearance extended 17 inches minimum under the element; with knee clearance at least 11 inches deep at 9 inches high and at least 8 inches deep at 27 inches high; and with a dining or work surface between 28 inches and 34 inches high.  They shall be distributed throughout the facility, if applicable.

6 months

70

Ahiki Cottage

Ahiki A
Toilets and Showers

213.3.2, 604.7, 609.3

The toilet paper dispenser is 2 inches in front of the front edge of the toilet.

Provide a toilet paper dispenser that is mounted with its centerline between 7 and 9 inches from the front of the toilet and with its outlet between 15 and 48 inches high with continuous paper flow that does not control delivery.  The dispenser shall be mounted either at least 1½ inches below the side grab bar or at least 12 inches above the side grab bar.

6 months

71

213.3.4, 606.3, 606.4,

The pipes are not covered or otherwise designed to protect against contact.

Provide a lavatory with the water and supply drain pipes are insulated or otherwise configured to protect against contact.

6 months

72

205.1, 305, 308.2, 308.3

The soap dispenser is mounted 68 1/2 inches above the finished foor.

Operable parts and controls of this element shall be no more than 48 inches high for a forward reach, or no more than 44 inches high if over an obstruction between 20 and 25 inches deep (for a forward reach, obstructions may not be deeper than 25 inches and obstructions must allow knee space); or mounted not more than 48 inches high for a side reach, or no more than 46 inches high if over an obstruction between 10 and 24 inches deep (for a side reach, obstruction may not be deeper than 24 inches); and accompanied by clear floor space of 30 inches by 48 inches that allows a forward or parallel approach, respectively, by a person using a wheelchair.

6 months

73

213.3.6, 610.3

There is no fixed shower seat provided.

In transfer type shower compartments, provide a seat mounted between 17 and 19 inches high on the wall opposite the controls extending from within 1½ inches of the back wall to within 3 inches of the compartment entry.  If the seat is rectangular, it should extend from 2½ inches to between 15 and 16 inches from the wall on which it is mounted.  If the seat is L-shaped, the portion near the compartment entry should extend from 2½ inches to between 15 and 16 inches from the wall on which it is mounted, and the portion near the back wall should extend between 14 and 15 inches from the back wall and between 22 and 23 inches from the wall on which it is mounted.

12 months

74

222.1, 305, 803.4, 903

The bench is 18 inches deep with short end attached at the wall.

Provide a bench with a seat at least 42 inches long and between 20 and 24 inches deep that is either affixed to a wall or has a back support that is at least 42 inches long, is no more than 2½ inches horizontally from the rear edge of the seat, and extends from no more than 2 inches to at least 18 inches above the seat.  The top of the seat shall be between 17 and 19 inches high and shall provide clear floor space at the end of the bench parallel to the bench’s short axis.

12 months

75

Kaala Cottage

Medical Dispensary

227.3, 305, 306, 904.4

The medical dispensary counter is 42 inches above the finished floor.

Provide counters dispersed throughout the facility (dispersion is not required where only 1 counter is provided) on accessible routes such that each counter has a portion extending the same depth as the counter top and no more than 36 inches high.  If a parallel approach is provided, the accessible portion of the counter shall be at least 36 inches long (unless the entire counter is less than 36 inches high) and have clear floor space positioned for a parallel approach; if a forward approach is provided, the accessible portion of the counter shall be at least 30 inches long and have knee and toe space provided under the counter and clear floor space positioned for a forward approach.

6 months

76

Kaala Cottage

Drinking Fountain

206, 307

The drinking fountain in the yard protrudes into the accessible walkway.

Unless protected by a cane detectable barrier, objects with their leading edges between 27 inches and 80 inches high shall not protrude into circulation paths more than 4 inches for wall-mounted elements, or 12 inches for free standing post- or pylon-mounted elements.  Protruding objects (and cane-detectable barriers) shall not reduce the clear width of accessible routes or maneuvering spaces below minimum requirements.

6 months

77

Kaala Cottage

Dining and Day Room

226, 305, 306, 902

None of the tables in the dining room are accessible.

At least 5% (but no fewer than 1) of dining or work surfaces shall be available for use by people with mobility disabilities.  Each accessible dining or work surface shall be on an accessible route; with clear floor space 30 inches wide by 48 inches deep positioned for a forward approach; with toe clearance extended 17 inches minimum under the element; with knee clearance at least 11 inches deep at 9 inches high and at least 8 inches deep at 27 inches high; and with a dining or work surface between 28 inches and 34 inches high.  They shall be distributed throughout the facility, if applicable.

6 months

78

Kaala Cottage

Dormitory C

Shower Room

213.3.6, 610.3

Neither designated accessible showers have  fixed shower seats and a shower spray unit or fixed lower shower head.

In transfer type shower compartments, provide a seat mounted between 17 and 19 inches high on the wall opposite the controls extending from within 1½ inches of the back wall to within 3 inches of the compartment entry.  If the seat is rectangular, it should extend from 2½ inches to between 15 and 16 inches from the wall on which it is mounted.  If the seat is L-shaped, the portion near the compartment entry should extend from 2½ inches to between 15 and 16 inches from the wall on which it is mounted, and the portion near the back wall should extend between 14 and 15 inches from the back wall and between 22 and 23 inches from the wall on which it is mounted.

12 months

79

Kaala Cottage

Dormitory C

Designated Accessible Cell

213.3.5, 603.3

The reflective surface of the mirror is mounted 41 inches above the floor.

Provide a mirror with the bottom edge of its reflectivg surface no more than 40 inches above the finished floor.

6 months

80

Kaala Cottage

Dormitory A and B

28 C.F.R. §35.151(k), 232, 807.

There are no accessible cells in Dormitory A or B. 

For new and altered facilities, the prison shall provide a minimum of 3% accessible cells, but no fewer than one, of the total number of cells in Administrative Segregation.  To be accessible, all of the cells' elements, including door, clear floor space, water closet, grab bars, lavatory, mirror, bed, desk, controls, and dispensers comply with the ADA Standards. 

36 months

81

Intake Unit

Toilet Room

204, 205, 206, 213, 216, 225, 301.1, 401.1, 601.1, 703, 811

No accessible features in the toilet room.

Provide an accessible toilet room such that all of the room’s elements, including signage, door, door hardware, clear floor space, toilet, stall size and arrangement (if any), urinal (if provided), grab bars, lavatory, mirror, controls, and dispensers, comply with the Standards.

36 months

82

Intake Unit

Holding Cell

213.3.2, 301.1,  604, 604.8.1, 609, 213.3.4, 305, 306, 309, 606.

The holding cell does not have an accessible toilet/lavatory.

Provide a toilet such that all of it’s elements, toilet, size and arrangement, toe clearances, grab bars, controls, and dispensers, comply with the Standards.  Provide a lavatory sink with the top of the rim or counter 34 inches high or less; knee clearance at least 30 inches wide, between 9 inches and 27 inches high, extending between 11 and 25 inches deep at 9 inches high, and extending at least 8 inches deep at 27 inches high; and toe clearance at least 30 inches wide and 9 inches high, and extending between 17 and 25 inches deep under the lavatory; water supply and drain pipes insulated or otherwise configured to protect against contact; no sharp or abrasive surfaces underneath; clear floor space at least 30 inches wide by 48 inches deep positioned for a forward approach.

36 months

83

Medical Unit

Dental exam room

206.4, 206.5, 309.4, 404.2.7

The door hardware on dental exam room door requires tight grasping, pinching, or twisting of the wrist.

Provide a door with hardware, mounted between 34 and 48 inches high, that is operable with one hand and does not require tight grasping, pinching, or twisting of the wrist and requires no more than 5 pounds of force to operate. Lever-operated mechanisms, push-type mechinisms, and U-shaped handles are acceptable designs.

6 months

84

Medical Unit

Medical Unit Inmate Toilet Room

204, 205, 206, 213, 216, 225, 301.1, 401.1, 601.1, 703, 811

The inmate toilet room has no accessible features.

Provide an accessible toilet room such that all of the room’s elements, including signage, door, door hardware, clear floor space, toilet, stall size and arrangement (if any), urinal (if provided), grab bars, lavatory, mirror, controls, and dispensers, comply with the Standards.

36 months

85

213.3.4, 606.3, 606.4

The lavatory pipes are not covered or otherwise designed to protect against contact.

Provide a lavatory with the water and supply drain pipes are insulated or otherwise configured to protect against contact.

6 months

86

213.3.5, 603.3

The reflective surface of the mirror is mounted 53 inches above the floor.

Provide a mirror with the bottom edge of its reflectivg surface no more than 40 inches above the finished floor.

3 months

87

213.3.2, 604.4

The toilet seat is 15 inches above the floor.

Provide a toilet with the top of the seat 17 to 19 inches high.  The seat shall not be sprung to return to a lifted position.

6 months

88

213.3.2, 604.5.2

There is no rear grab bar mounted at the toilet.

Provide a rear grab bar that is at least 36 inches long (except where wall space does not permit it dues to the location of a recessed fixture, in which case the grab bar may be 24 inches long), extend 12 inches from the toilet centerline on one side and 24 inches on the other side (excpet where an administrative autority requires flush controls to be located in a position that conflicts with the location of the rear grab bar, in which case the bar may be split or shifted to the open side. 

6 months

89

Medical Unit

Ward A: Tub and Shower Room

213.3.6, 608.6

Shower does not have lower or adjustable shower head.

Provide a shower spray unit with a hose at least 59 inches long that can be used both as a fixed shower head and as a hand-held shower, with an on/off control with a non-positive shutoff, that delivers water no hotter than 120 degrees.  In facilities that are not medical care facilities, long-term care facilities, transient lodging guest rooms, or residential dwelling units, a fixed shower head mounted at 48 inches above the shower floor may be used in lieu of a hand-held shower head. 

36 months

90

Medical Unit

Ward A: Cells

28 C.F.R. §35.151(k), 232, 807.

There is less than 3% of the total number of accessible cells provided in Ward A.

For new and altered facilities, the prison shall provide a minimum of 3% accessible cells, but no fewer than one, of the total number of cells in Ward A.  To be accessible, all of the cells' elements, including door, clear floor space, water closet, grab bars, lavatory, mirror, bed, desk, controls, and dispensers comply with the ADA Standards. 

36 months

91

Medical Unit

Ward B : Tub and Shower Room

 213.3.6, 607, 609, 610.

Tub has no accessible features.

Provide a permanent seat at the head end of the bathtub or a removable end-tub seat.  Provide two parallel horizontal grab bars on the back (long) wall of the bathtub, one mounted between 8 inches and 10 inches above the rim of the bathtub and the other mounted between 33 inches and 36 inches above the bathroom floor.  If the bathtub has a permanent seat, these two grab bars shall be 15 inches maximum from the head end wall and 12 inches maximum from the foot end wall; if the bathtub does not have a permanent seat, these two grab bars shall be 24 inches long minimum and shall be mounted 24 inches maximum from the head end wall and 12 inches maximum from the foot end wall.  Provide one horizontal grab bar at the foot end of the bathtub that extends at least 24 inches from the outer edge of the bathtub toward the back (long) wall of the tub between 33 inches and 36 inches high.  If the bathtub does not have a permanent seat, provide one horizontal grab bar at least 12 inches long located on the head end wall, towards the outside of the tub between 33 inches and 36 inches high.

36 months

92

213.3.5, 603.3

The reflective surface of the mirror is mounted higher than 40 inches above the floor.

Provide a mirror with the bottom edge of its reflectivg surface no more than 40 inches above the finished floor.

3 months

93

Medical Unit

Ward B: Cells

28 C.F.R. §35.151(k), 232, 807.

There is less than 3% of the total number of accessible cells provided in Ward A.

For new and altered facilities, the prison shall provide a minimum of 3% accessible cells, but no fewer than one, of the total number of cells in Ward B.  To be accessible, all of the cells' elements, including door, clear floor space, water closet, grab bars, lavatory, mirror, bed, desk, controls, and dispensers comply with the ADA Standards. 

36 months

94

Module 2

Medical Request and Mail Box

205, 309.3

The medical request is mounted with the slot 46 inches and the mailbox slot at 50 inches above the finished floor.

Provide this element in a location where there is a compliant 30 inch by 48 inch clear floor space and that the operable parts are within 48 inches of the floor.  If a forward approach is required, the clear floor space may extend under an obstruction with a maximum depth of 25 inches.  If the obstruction is 20 inches to 25 inches deep, the operable parts must be mounted within 44 inches of the floor.  If a side approach is possible, the operable parts may be obstructed for a maximum height of 34 inches and for a maximum depth of 24 inches.  When this obstruction is deeper than 10 inches the operable parts must be within 46 inches of the floor.

6 months

95

Module 2

Quad 3, Block A: Designated Accessible Cells

28 C.F.R. §35.151(k), 232, 807.

There is less than 3% of the total number of accessible cells provided in Ward A.

For new and altered facilities, the prison shall provide a minimum of 3% accessible cells, but no fewer than one, of the total number of cells in Administrative Segregation.  To be accessible, all of the cells' elements, including door, clear floor space, water closet, grab bars, lavatory, mirror, bed, desk, controls, and dispensers comply with the ADA Standards. 

36 months

96

Module 2

Quad 3, Block A: Showers

206.5, 213.2, 213.3.6, 404, 603, 608

There is no accessible shower.

Provide a transfer shower that is exactly 36 inches wide and 36 inches deep with a 48 inch long and 36 inch wide clear floor space alongside the shower opening, and an L-shaped shower seat mounted on the wall opposite the controls and extending the full depth of the stall; OR a shower that is at least 30 inches deep and 60 inches wide with no curb or threshold and with a 36 inch deep and 60 inch wide clear floor space at the shower opening.  Ensure that the shower has grab bars, controls, a shower spray unit, and a seat, curb, and enclosure, if provided, that comply fully with the Standards.

36 months

97

Module 2

Entry into Block A Recreation Yard

206.5, 302, 303, 404.2.5.

There is a one inch threshold at the door into the recreation yard.

Provide an accessible door with a threshold that is no more than ¼ inch high, or is between ¼ inch and ½ inch high (¾ inch high if the threshold is existing or altered) and is beveled with a slope no greater than 50%.

6 months

98

Module 3

Quad 3, Block A, Designated Accessible Cells

28 C.F.R. §35.151(k), 232, 807.

There is less than 3% of the total number of accessible cells provided in Module 3

For new and altered facilities, the prison shall provide a minimum of 3% accessible cells, but no fewer than one, of the total number of cells in Administrative Segregation.  To be accessible, all of the cells' elements, including door, clear floor space, water closet, grab bars, lavatory, mirror, bed, desk, controls, and dispensers comply with the ADA Standards. 

36 months

99

Module 3

Quad 3, Block A Showers

206.5, 213.2, 213.3.6, 404, 603, 608

There is no accessible shower.

Provide a transfer shower that is exactly 36 inches wide and 36 inches deep with a 48 inch long and 36 inch wide clear floor space alongside the shower opening, and an L-shaped shower seat mounted on the wall opposite the controls and extending the full depth of the stall; OR a shower that is at least 30 inches deep and 60 inches wide with no curb or threshold and with a 36 inch deep and 60 inch wide clear floor space at the shower opening.  Ensure that the shower has grab bars, controls, a shower spray unit, and a seat, curb, and enclosure, if provided, that comply fully with the Standards.

36 months

100

Module 4

Quad 3, Block A, Designated Accessible Cells

28 C.F.R. §35.151(k), 232, 807.

There is less than 3% of the total number of accessible cells provided in Module 4.

For new and altered facilities, the prison shall provide a minimum of 3% accessible cells, but no fewer than one, of the total number of cells in Administrative Segregation.  To be accessible, all of the cells' elements, including door, clear floor space, water closet, grab bars, lavatory, mirror, bed, desk, controls, and dispensers comply with the ADA Standards. 

36 months

101

Module 4

Quad 3, Block A Showers

206.5, 213.2, 213.3.6, 404, 603, 608

There is no accessible shower.

Provide a transfer shower that is exactly 36 inches wide and 36 inches deep with a 48 inch long and 36 inch wide clear floor space alongside the shower opening, and an L-shaped shower seat mounted on the wall opposite the controls and extending the full depth of the stall; OR a shower that is at least 30 inches deep and 60 inches wide with no curb or threshold and with a 36 inch deep and 60 inch wide clear floor space at the shower opening.  Ensure that the shower has grab bars, controls, a shower spray unit, and a seat, curb, and enclosure, if provided, that comply fully with the Standards.

36 months

102

Module 1 Because Module 1's security system was under repair during the facility visit, this report does not include Module 1. HDPS represented that Module 1 is identical to Modules 2, 3, and 4, and thus, architectural violations found in those modules can likely also be found at Module 1. Such violations should be addressed in the same manner as those violations outlined above for Modules 2, 3, and 4.

36 months

103

Gymnasium

Indoor Inmate Toilet Room

213.3.5, 603.3

The reflective surface of the mirror is mounted more than 40 inches above the floor.

Provide a mirror with the bottom edge of its reflectivg surface no more than 40 inches above the finished floor.

3 months

104

205.1, 305, 308.2, 308.3

There is no accessible soap dispenser provided.

Operable parts and controls of this element shall be no more than 48 inches high for a forward reach, or no more than 44 inches high if over an obstruction between 20 and 25 inches deep (for a forward reach, obstructions may not be deeper than 25 inches and obstructions must allow knee space); or mounted not more than 48 inches high for a side reach, or no more than 46 inches high if over an obstruction between 10 and 24 inches deep (for a side reach, obstructions may not be deeper than 24 inches); and accompanied by clear floor space of 30 inches by 48 inches that allows a forward or parallel approach, respectively, by a person using a wheelchair. 

3 months

105

213.3.3, 305, 308.2, 309.4, 605.

The urinals are mounted with the rim mounted 19 inches above the fnished floor.

Provide a stall-type or a wall-hung urinal with a rim mounted 17 inches high or less; a depth of at least 13½ inches from the outer face to the rear of the urinal; a clear floor space at least 30 inches wide and 48 inches deep positioned for a forward approach; and a flush control between 15 and 48 inches high or an automatic flush.

36 months

106

213.3.1, 301.1, 404, 604, 604.8.1, 609; 28 C.F.R. § 35.133

The designated accessible toilet compartment is not operational and is not accessible.

Provide an accessible toilet compartment at least 60 inches wide and at least 59 inches deep (or at least 56 inches deep with a wall-mounted toilet) such that all of the compartment’s elements, including door, door hardware, toilet, size and arrangement, toe clearances, grab bars, controls, and dispensers, comply with the Standards.  Maintain this feature in operable working condition.

36 months

107

Gymnasium

Outdoor Staff Toilet Room and Designated ADA Inmate Toilet Room

213.3.4, 606.3, 606.4

The lavatory pipes are not covered or otherwise designed to protect against contact.

Provide a lavatory with the water and supply drain pipes are insulated or otherwise configured to protect against contact.

6 months

108

213.3.5, 603.3

The reflective surface of the mirror is mounted more than 40 inches above the floor.

Provide a mirror with the bottom edge of its reflectivg surface no more than 40 inches above the finished floor.

3 months

109

205.1, 305, 308.2, 308.3

Soap dispenser is mounted more than 48 inches above the floor.

Operable parts and controls of this element shall be no more than 48 inches high for a forward reach, or no more than 44 inches high if over an obstruction between 20 and 25 inches deep (for a forward reach, obstructions may not be deeper than 25 inches and obstructions must allow knee space); or mounted not more than 48 inches high for a side reach, or no more than 46 inches high if over an obstruction between 10 and 24 inches deep (for a side reach, obstructions may not be deeper than 24 inches); and accompanied by clear floor space of 30 inches by 48 inches that allows a forward or parallel approach, respectively, by a person using a wheelchair. 

3 months

110

213.3.3, 305, 308.2, 309.4, 605; 28 C.F.R. § 35.133

Urinal is not operational.

Provide a stall-type or a wall-hung urinal with a rim mounted 17 inches high or less; a depth of at least 13½ inches from the outer face to the rear of the urinal; a clear floor space at least 30 inches wide and 48 inches deep positioned for a forward approach; and a flush control between 15 and 48 inches high or an automatic flush. Maintain this feature in operable working condition.

12 months

111

604.5.1

The far end of the side grab bar extends 51 inches from the rear wall.

Provide a side bar that is at least 42 inches long and mounted a maximum 12 inches from the back wall. The end of the grab bar must extend a minimum of 54 inches from the back wall.

6 months

112

213.3.2, 309.4, 604.6

The flush control is mounted on the closed side of the toilet.

Provide a flush control mounted on the “open” side of the toilet’s clear floor space, between 15 and 48 inches high, and requiring a maximum of 5 pounds of force to operate; or provide an automatic flush device.

6 months

113

Gymnasium

Entrance to Gymnasium

206.5, 302, 303, 404.2.5.

There is a one inch threshold at the door into the gymnasium

Provide an accessible door with a threshold that is no more than ¼ inch high, or is between ¼ inch and ½ inch high (¾ inch high if the threshold is existing or altered) and is beveled with a slope no greater than 50%.

6 months

Table: Halawa Correctional Facility - Special Needs / High Facility

No.

Location

2010 Standards Citations

Violations

Requirement/Action Required

Completion Date

114

Visiting Area

Entrance to Visitor Lobby- Ramp

206.1, 405, 505.2

The ramp at the entrance into the building is noncomplaint.

Provide a ramp that is at least 36 inches wide with a slope not exceeding 8.33% and a cross slope not exceeding 2%; with level landings at least as wide as the ramp and 60 inches long at the top and bottom of the ramp; with level landings measuring at least 60 inches by 60 inches when the ramp changes direction; with no level changes in excess of ½ inch vertically and no level changes greater than ¼ inch vertically unless they are beveled with a slope no greater than 50%; and with edge protection that is at least 2 inches high at the drop off sides.  Provide handrails that are between 1¼ inches and 1½ inches in diameter such that the inside handrail is continuous and both handrails have a continuous gripping surface along both sides of the ramp extending at least 12 inches beyond the top and bottom of the ramp parallel with the ground surface; the handrails do not rotate within their fittings; and both handrails are mounted with the tops between 34 inches and 38 inches above the ramp surface and at least 1½ inches from the wall, with ends rounded or returned smoothly to the floor, wall, or post.  Alternatively, provide a wheelchair and a wheelchair pusher for inmates who cannot ambulate this walkway.

24 months

115

Visiting Area

Unisex Single-User Toilet Room

206.5, 404.2.9

The door requires 9 pounds of force to open.

Provide a door that requires no more than 5 pounds of force to open (not including the initial force needed to overcome inertia, retracting bolts, etc.).

6 months

116

213.3.5, 603.3

The reflective surface of the mirror is mounted 47 inches above the floor.

Provide a mirror with the bottom edge of its reflecting surface no more than 40 inches above the finished floor.

3 months

117

213.3.4, 606.3, 606.4

The lavatory pipes are not covered or otherwise designed to protect against contact.

Provide a lavatory with the water and supply drain pipes are insulated or otherwise configured to protect against contact.

6 months

118

213.3.2, 604.4

The toilet seat is 16 inches above the floor.

Provide a toilet with the top of the seat 17 to 19 inches high.  The seat shall not be sprung to return to a lifted position.

6 months

119

213.3.2, 604.5, 609.3

Space between side grab bar and wall is 3"

Provide grab bars that have at least 1½ inches between the grab bar and any object projecting beside or below it.

6 months

120

213.3.2, 604.5, 609.3.

Seat covers obstruct side grab bar

Provide a side grab bar that has at least 12 inches between the grab bar and any object projecting above it.

6 months

121

213.3.2, 604.5, 609.3

Space between rear grab bar and wall is 3"

Provide grab bars that have at least 1½ inches between the grab bar and any object projecting beside or below it.

6 months

122

213.3.2, 604.5.2

Rear grab bar is 24" long

Provide a rear grab bar that is at least 36 inches long (except where wall space does not permit it due to the location of a recessed fixture, in which case the grab bar may be 24 inches long and centered on the toilet), extending 12 inches from the toilet centerline on one side and 24 inches from the toilet centerline on the other side (except where an administrative authority requires flush controls to be located in a position that conflicts with the location of the rear grab bar, in which case the bar may be split or shifted to the open side).

6 months

123

Special Holding Unit

Module 5 - RAD Unit

28 C.F.R. §35.151(k), 232, 807.

There is less than 3% of the total number of accessible cells provided in Module 5.

For new and altered facilities, the prison shall provide a minimum of 3% accessible cells, but no fewer than one, of the total number of cells in Administrative Segregation.  To be accessible, all of the cells' elements, including door, clear floor space, water closet, grab bars, lavatory, mirror, bed, desk, controls, and dispensers comply with the ADA Standards. 

36 months

124

Special Holding Unit

Law Library

226, 305, 306, 902

The law library kiosk is not accessible to people with mobility diabilities

At least 5% (but no fewer than 1) of dining or work surfaces shall be available for use by people with mobility disabilities.  Each accessible dining or work surface shall be on an accessible route; with clear floor space 30 inches wide by 48 inches deep positioned for a forward approach; with toe clearance extended 17 inches minimum under the element; with knee clearance at least 11 inches deep at 9 inches high and at least 8 inches deep at 27 inches high; and with a dining or work surface between 28 inches and 34 inches high.  They shall be distributed throughout the facility, if applicable.

6 months

 

Table: Oahu Community Correctional Center

No.

Location

2010 Standards Citations

Violations

Requirement/Action Required

Completion Date

125

Module 20

C & D Units

Toilets / Bathrooms

213.3.2, 604.2

The centerline of the toilet is 19 inches from the side wall.

Provide a toilet with its centerline between 16 and 18 inches from the near side wall.

36 months

126

2.13.3.6, 608.2.1, 610

The shower compartment is 36 inches by 34 inches and there is only 11 inches of  transfer space on the  side opposite the controls.

The shower compartment shall be 36 inches by 36 inches, the entrance shall be at least 36 inches wide, and clearance adjacent to the opening shall be 36 inches wide by 48 inches long measured from the control wall (so that the clearance extends beyond the seat).

36 months

127

213.3.6, 608.6

The handheld shower spray is mounted 53 inches above the floor.

Provide a shower spray unit with a hose at least 59 inches long that can be used both as a fixed shower head and as a hand-held shower, with an on/off control with a non-positive shutoff, that delivers water no hotter than 120 degrees.  In facilities that are not medical care facilities, long-term care facilities, transient lodging guest rooms, or residential dwelling units, a fixed shower head mounted at 48 inches above the shower floor may be used in lieu of a hand-held shower head. 

12 months

128

213.3.6, 610.3

There is no fixed shower seat provided.

In transfer type shower compartments, provide a seat mounted between 17 and 19 inches high on the wall opposite the controls extending from within 1½ inches of the back wall to within 3 inches of the compartment entry.  If the seat is rectangular, it should extend from 2½ inches to between 15 and 16 inches from the wall on which it is mounted.  If the seat is L-shaped, the portion near the compartment entry should extend from 2½ inches to between 15 and 16 inches from the wall on which it is mounted, and the portion near the back wall should extend between 14 and 15 inches from the back wall and between 22 and 23 inches from the wall on which it is mounted.

36 months

129

205.1, 305, 308.2, 308.3

The coathooks are mounted at 63 inches above the finish floor.

Operable parts and controls of this element shall be no more than 48 inches high for a forward reach, or no more than 44 inches high if over an obstruction between 20 and 25 inches deep (for a forward reach, obstructions may not be deeper than 25 inches and obstructions must allow knee space); or mounted not more than 48 inches high for a side reach, or no more than 46 inches high if over an obstruction between 10 and 24 inches deep (for a side reach, obstructions may not be deeper than 24 inches); and accompanied by clear floor space of 30 inches by 48 inches that allows a forward or parallel approach, respectively, by a person using a wheelchair. 

6 months

130

213.3.6, 608

The bench obstructs the manuevering clearance at the shower opening.

Provide a transfer shower where the entrance shall be at least 36 inches wide, and clearance adjacent to the opening shall be 36 inches wide by 48 inches long measured from the control wall (so that the clearance extends beyond the seat)

6 months

131

222.1, 305, 803.4, 903

The bench is 11 inches deep with short end attached at the wall.

Provide a bench with a seat at least 42 inches long and between 20 and 24 inches deep that is either affixed to a wall or has a back support that is at least 42 inches long, is no more than 2½ inches horizontally from the rear edge of the seat, and extends from no more than 2 inches to at least 18 inches above the seat.  The top of the seat shall be between 17 and 19 inches high and shall provide clear floor space at the end of the bench parallel to the bench’s short axis.

6 months

132

Module 20

A & B Units

Toilets / Bathrooms

213.3.2, 604.2

The centerline of the toilet is 19 inches from the side wall.

Provide a toilet with its centerline between 16 and 18 inches from the near side wall.

36 months

133

2.13.3.6, 608.2.1, 610

The shower compartment is 36 inches by 34 inches and there is only 11 inches of  transfer space on the  side opposite the controls.

The shower compartment shall be 36 inches by 36 inches, the entrance shall be at least 36 inches wide, and clearance adjacent to the opening shall be 36 inches wide by 48 inches long measured from the control wall (so that the clearance extends beyond the seat).

36 months

134

213.3.6, 608.6

The handheld shower spray is mounted 53 inches above the floor.

Provide a shower spray unit with a hose at least 59 inches long that can be used both as a fixed shower head and as a hand-held shower, with an on/off control with a non-positive shutoff, that delivers water no hotter than 120 degrees.  In facilities that are not medical care facilities, long-term care facilities, transient lodging guest rooms, or residential dwelling units, a fixed shower head mounted at 48 inches above the shower floor may be used in lieu of a hand-held shower head. 

12 months

135

205.1, 305, 308.2, 308.3

The coathooks are mounted at 63 inches above the finish floor.

Operable parts and controls of this element shall be no more than 48 inches high for a forward reach, or no more than 44 inches high if over an obstruction between 20 and 25 inches deep (for a forward reach, obstructions may not be deeper than 25 inches and obstructions must allow knee space); or mounted not more than 48 inches high for a side reach, or no more than 46 inches high if over an obstruction between 10 and 24 inches deep (for a side reach, obstructions may not be deeper than 24 inches); and accompanied by clear floor space of 30 inches by 48 inches that allows a forward or parallel approach, respectively, by a person using a wheelchair. 

36 months

136

Module 20

A, B, C, D Units
Dorms

28 C.F.R. §35.151(k), 232, 807.

There is one accessible bed provided. 

For new and altered facilities, the prison shall provide a minimum of 3% accessible cells (2), but no fewer than one, of the total number of cells in Administrative Segregation.  To be accessible, all of the cells' elements, including door, clear floor space, water closet, grab bars, lavatory, mirror, bed, desk, controls, and dispensers comply with the ADA Standards. 

12 months

137

Module 20Recreation Area

226, 305, 306, 902

None of the outdoor tables are accessible.

At least 5% (but no fewer than 1) of dining or work surfaces shall be available for use by people with mobility disabilities.  Each accessible dining or work surface shall be on an accessible route; with clear floor space 30 inches wide by 48 inches deep positioned for a forward approach; with toe clearance extended 17 inches minimum under the element; with knee clearance at least 11 inches deep at 9 inches high and at least 8 inches deep at 27 inches high; and with a dining or work surface between 28 inches and 34 inches high.  They shall be distributed throughout the facility, if applicable.

12 months

138

Module  5 - Intake Unit

Men's Toilet and Shower

204, 205, 206, 213, 216, 225, 301.1, 401.1, 601.1, 703, 811

The toilet and lavatory are not accessible.

Provide an accessible toilet room such that all of the room’s elements, including signage, door, door hardware, clear floor space, toilet, stall size and arrangement (if any), urinal (if provided), grab bars, lavatory, mirror, controls, and dispensers, comply with the Standards.

36 months

139

206.5, 213.2, 213.3.6, 404, 603, 608

There is no accessible shower.

Provide a transfer shower that is exactly 36 inches wide and 36 inches deep with a 48 inch long and 36 inch wide clear floor space alongside the shower opening, and an L-shaped shower seat mounted on the wall opposite the controls and extending the full depth of the stall; OR a shower that is at least 30 inches deep and 60 inches wide with no curb or threshold and with a 36 inch deep and 60 inch wide clear floor space at the shower opening.  Ensure that the shower has grab bars, controls, a shower spray unit, and a seat, curb, and enclosure, if provided, that comply fully with the Standards.

36 months

140

Module  5 - Intake Unit

Women's Toilet and Shower

204, 205, 206, 213, 216, 225, 301.1, 401.1, 601.1, 703, 811

The toilet and lavatory are not accessible.

Provide an accessible toilet room such that all of the room’s elements, including signage, door, door hardware, clear floor space, toilet, stall size and arrangement (if any), urinal (if provided), grab bars, lavatory, mirror, controls, and dispensers, comply with the Standards.

36 months

141

206.5, 213.2, 213.3.6, 404, 603, 608

There is no accessible shower.

Provide a transfer shower that is exactly 36 inches wide and 36 inches deep with a 48 inch long and 36 inch wide clear floor space alongside the shower opening, and an L-shaped shower seat mounted on the wall opposite the controls and extending the full depth of the stall; OR a shower that is at least 30 inches deep and 60 inches wide with no curb or threshold and with a 36 inch deep and 60 inch wide clear floor space at the shower opening.  Ensure that the shower has grab bars, controls, a shower spray unit, and a seat, curb, and enclosure, if provided, that comply fully with the Standards.

36 months

142

Module  5 - Intake Unit

Dental office

206, 403.5.1

There is no accessible route to the dental chair.

Provide to each area, feature, or element described an accessible route with a minimum clear width of 36 inches, except that the width may decrease to 32 inches for a depth of no more than 24 inches.

3 months

143

Module  5 - Intake Unit

Medical Unit

204, 205, 206, 213, 216, 225, 301.1, 401.1, 601.1, 703, 811

There are no accessible features in the men's or women's toilet rooms.

Provide an accessible toilet room such that all of the room’s elements, including signage, door, door hardware, clear floor space, toilet, stall size and arrangement (if any), urinal (if provided), grab bars, lavatory, mirror, controls, and dispensers, comply with the Standards.

36 months

144

Module  5 - Intake Unit

Medical Unit - Route to toilet rooms

Standards §§ 206, 301.1, 401.1.

The trash can obstructs accessible route to toilet rooms.

To each area, feature, or element described, provide at least one accessible route that coincides with or is located in the same area as general circulation paths.  The accessible route must have a minimum clear width of 36 inches (except that it may narrow to no less than 32 inches for a length of no more than 24 inches), or a minimum clear width of 42 inches if there is a U-turn around an obstruction less than 48 inches wide; have passing spaces at least every 200 feet; have a minimum clear headroom of 80 inches; have a surface that is firm, stable, and slip resistant; have, in the absence of a curb ramp, ramp, elevator, or platform lift, no level changes in excess of ½ inch vertically; have no level changes greater than ¼ inch vertically unless they are beveled with a slope no greater than 50%; and have a running slope no greater than 5% (or have been constructed as a fully accessible ramp) and a cross slope no greater than 2.08%.

3 months

145

IModule  5 - Intake Unit

nfirmary

204, 205, 206, 213, 216, 225, 301.1, 401.1, 601.1, 703, 811

The toilet and lavatory are not accessible.

Provide an accessible toilet room such that all of the room’s elements, including signage, door, door hardware, clear floor space, toilet, stall size and arrangement (if any), urinal (if provided), grab bars, lavatory, mirror, controls, and dispensers, comply with the Standards.

36 months

146

206.5, 213.2, 213.3.6, 404, 603, 608

There is no accessible shower.

Provide a transfer shower that is exactly 36 inches wide and 36 inches deep with a 48 inch long and 36 inch wide clear floor space alongside the shower opening, and an L-shaped shower seat mounted on the wall opposite the controls and extending the full depth of the stall; OR a shower that is at least 30 inches deep and 60 inches wide with no curb or threshold and with a 36 inch deep and 60 inch wide clear floor space at the shower opening.  Ensure that the shower has grab bars, controls, a shower spray unit, and a seat, curb, and enclosure, if provided, that comply fully with the Standards.

36 months

147

Module 8 - Women's Acute Mental Health Unit 

206.5, 213.2, 213.3.6, 404, 603, 608

There is no accessible shower.

Provide a transfer shower that is exactly 36 inches wide and 36 inches deep with a 48 inch long and 36 inch wide clear floor space alongside the shower opening, and an L-shaped shower seat mounted on the wall opposite the controls and extending the full depth of the stall; OR a shower that is at least 30 inches deep and 60 inches wide with no curb or threshold and with a 36 inch deep and 60 inch wide clear floor space at the shower opening.  Ensure that the shower has grab bars, controls, a shower spray unit, and a seat, curb, and enclosure, if provided, that comply fully with the Standards.

36 months

148

 Module 8 - Women's Acute Mental Health Unit

28 C.F.R. §35.151(k), 232, 807.

There is less than 3% of the total number of accessible cells provided in Module 8.

For new and altered facilities, the prison shall provide a minimum of 3% accessible cells, but no fewer than one, of the total number of cells in Administrative Segregation.  To be accessible, all of the cells' elements, including door, clear floor space, water closet, grab bars, lavatory, mirror, bed, desk, controls, and dispensers comply with the ADA Standards. 

36 months

149

Module 3 - Women's General Population, Medium Security

206.5, 213.2, 213.3.6, 404, 603, 608

There is no accessible shower.

Provide a transfer shower that is exactly 36 inches wide and 36 inches deep with a 48 inch long and 36 inch wide clear floor space alongside the shower opening, and an L-shaped shower seat mounted on the wall opposite the controls and extending the full depth of the stall; OR a shower that is at least 30 inches deep and 60 inches wide with no curb or threshold and with a 36 inch deep and 60 inch wide clear floor space at the shower opening.  Ensure that the shower has grab bars, controls, a shower spray unit, and a seat, curb, and enclosure, if provided, that comply fully with the Standards.

12 months

150

 Module 3 - Women's General Population, Medium Security

226, 305, 306, 902

None of the  tables in the module are accessible.

At least 5% (but no fewer than 1) of dining or work surfaces shall be available for use by people with mobility disabilities.  Each accessible dining or work surface shall be on an accessible route; with clear floor space 30 inches wide by 48 inches deep positioned for a forward approach; with toe clearance extended 17 inches minimum under the element; with knee clearance at least 11 inches deep at 9 inches high and at least 8 inches deep at 27 inches high; and with a dining or work surface between 28 inches and 34 inches high.  They shall be distributed throughout the facility, if applicable.

6 months

151

 Module 2 - Limited Mobility

205, 206, 213,  301.1, 401.1, 601.1

The toilet in the designated accessible cell has no accessible features.

Provide an accessible toilet room such that all of the room’s elements, including clear floor space, toilet, stall size and arrangement (if any), grab bars, lavatory, mirror, controls, and dispensers, comply with the Standards.

36 months

152

Module 2 - Limited Mobility

206.5, 213.2, 213.3.6, 404, 603, 608

There is no accessible shower.

Provide a transfer shower that is exactly 36 inches wide and 36 inches deep with a 48 inch long and 36 inch wide clear floor space alongside the shower opening, and an L-shaped shower seat mounted on the wall opposite the controls and extending the full depth of the stall; OR a shower that is at least 30 inches deep and 60 inches wide with no curb or threshold and with a 36 inch deep and 60 inch wide clear floor space at the shower opening.  Ensure that the shower has grab bars, controls, a shower spray unit, and a seat, curb, and enclosure, if provided, that comply fully with the Standards.

36 months

153

Module 1 - Male Acute Mental Health Unit

206.5, 213.2, 213.3.6, 404, 603, 608

There is no accessible shower.

Provide a transfer shower that is exactly 36 inches wide and 36 inches deep with a 48 inch long and 36 inch wide clear floor space alongside the shower opening, and an L-shaped shower seat mounted on the wall opposite the controls and extending the full depth of the stall; OR a shower that is at least 30 inches deep and 60 inches wide with no curb or threshold and with a 36 inch deep and 60 inch wide clear floor space at the shower opening.  Ensure that the shower has grab bars, controls, a shower spray unit, and a seat, curb, and enclosure, if provided, that comply fully with the Standards.

36 months

154

Module 1 - Male Acute Mental Health Unit

213.3.4, 305, 306, 309, 606.

The lavatory in shower area is not accessible.

Provide at least 5% of all lavatories and sinks with the top of the rim or counter 34 inches high or less; knee clearance at least 30 inches wide, between 9 inches and 27 inches high, extending between 11 and 25 inches deep at 9 inches high, and extending at least 8 inches deep at 27 inches high; and toe clearance at least 30 inches wide and 9 inches high, and extending between 17 and 25 inches deep under the lavatory; water supply and drain pipes insulated or otherwise configured to protect against contact; no sharp or abrasive surfaces underneath; clear floor space at least 30 inches wide by 48 inches deep positioned for a forward approach (except that a parallel approach with no knee and toe clearance can be provided at a kitchen sink where there is no cook top or conventional range and at wet bars); and a faucet that can be operated with no more than 5 pounds of force and can be used with one hand and without tight grasping, pinching, or twisting of the wrist (lever-operated, push-type, and electronically controlled mechanisms are examples of acceptable designs).  Hand-operated metering faucets shall remain open for at least 10 seconds.

12 months

155

Module 1 - Male Acute Mental Health Unit

28 C.F.R. §35.151(k), 232, 807.

There is less than 3% of the total number of accessible cells provided in Module 1.

For new and altered facilities, the prison shall provide a minimum of 3% accessible cells, but no fewer than one, of the total number of cells in Administrative Segregation.  To be accessible, all of the cells' elements, including door, clear floor space, water closet, grab bars, lavatory, mirror, bed, desk, controls, and dispensers comply with the ADA Standards. 

36 months

156

Interior Recreation Yards

206, 303

The routes into the interior recreation yards have a step.

Provide an accessible route to each area, feature, or element described such that level changes in excess of ½ inch are ramped (or otherwise made accessible); level changes with exposed edges of up to 90 degrees are not more than ¼ inch high; and level changes between ½ inch and ¼ inch high are beveled with a slope no greater than 50% (or up to ¼ inch vertical and at least ¼ inch beveled).

6 months

157

Toilet Room near Library

213.3.2, 604.3

The clear floor space at the toilet is obstructed by a second toilet.

Provide clearance at the toilet that is at least 60 inches wide and 56 inches deep.  This clearance may overlap with the toilet, grab bars, dispensers, coat hooks, shelves, accessible routes, clear floor space and clearances for other fixtures, and turning space; but no other fixtures or obstructions, including lavatories, may be located within this clearance.

12 months

158

Toilet Room near Library

213.3.2, 309.4, 604.6

The flush control is mounted on the closed side of the toilet.

Provide a flush control mounted on the “open” side of the toilet’s clear floor space, between 15 and 48 inches high, and requiring a maximum of 5 pounds of force to operate; or provide an automatic flush device.

6 months

159

Toilet Room near Library

213.3.2, 604.5, 609.3

The side grab bar is obstructed by toilet paper dispenser.

Provide grab bars that have at least 1½ inches between the grab bar and any object projecting beside or below it and at least 12 inches between the grab bar and any object projecting above it.

6 months

160

Toilet Room near Library

213.3.3, 305, 308.2, 309.4, 605.

The urinals are mounted wih the rim mounted approximately 20 inches above the fnished floor.

Provide a stall-type or a wall-hung urinal with a rim mounted 17 inches high or less; a depth of at least 13½ inches from the outer face to the rear of the urinal; a clear floor space at least 30 inches wide and 48 inches deep positioned for a forward approach; and a flush control between 15 and 48 inches high or an automatic flush.

36 months

161

Toilet Room near Library

213.3.4, 306, 606.2, 606.3

The apron of the lavatory is 25 inches above the finished floor.

Provide a lavatory with the top of the rim or counter 34 inches high or less; knee clearance at least 30 inches wide, between 9 inches and 27 inches high, extending between 11 and 25 inches deep at 9 inches high, and extending at least 8 inches deep at 27 inches high; and toe clearance at least 30 inches wide and 9 inches high, and extending between 17 and 25 inches deep under the lavatory.

36 months

162

Toilet Room near Library

213.3.4, 606.3, 606.4,

The pipes are not covered or otherwise designed to protect against contact.

Provide at least 5% of all lavatories and sinks with the top of the rim or counter 34 inches high or less; knee clearance at least 30 inches wide, between 9 inches and 27 inches high, extending between 11 and 25 inches deep at 9 inches high, and extending at least 8 inches deep at 27 inches high; and toe clearance at least 30 inches wide and 9 inches high, and extending between 17 and 25 inches deep under the lavatory; water supply and drain pipes insulated or otherwise configured to protect against contact.  Provide a faucet that can be operated with no more than 5 pounds of force and can be used with one hand and without tight grasping, pinching, or twisting of the wrist (lever-operated, push-type, and electronically controlled mechanisms are examples of acceptable designs).

6 months

163

Toilet Room near Library

205.1, 305, 308.2, 308.3

The soap dispenser is mounted 49 inches above the finished foor.

Operable parts and controls of this element shall be no more than 48 inches high for a forward reach, or no more than 44 inches high if over an obstruction between 20 and 25 inches deep (for a forward reach, obstructions may not be deeper than 25 inches and obstructions must allow knee space); or mounted not more than 48 inches high for a side reach, or no more than 46 inches high if over an obstruction between 10 and 24 inches deep (for a side reach, obstruction may not be deeper than 24 inches); and accompanied by clear floor space of 30 inches by 48 inches that allows a forward or parallel approach, respectively, by a person using a wheelchair.

6 months

164

Recreation Field/Ballfield

Toilet Room

204, 205, 206, 213, 216, 225, 301.1, 401.1, 601.1, 703, 811

The toilet and lavatory are not accessible.

Provide an accessible toilet room such that all of the room’s elements, including signage, door, door hardware, clear floor space, toilet, stall size and arrangement (if any), urinal (if provided), grab bars, lavatory, mirror, controls, and dispensers, comply with the Standards.

36 months

165

Visitation

Visitation Booths

232.5, 305, 306, 902, 904.4.2, 904.6.

There is no accessible visitation booth on the detainee side.

Provide a visitation or other such area such that at least 5% of cubicles provide accessible clear floor space and work surfaces on both the visitor and detainee sides.  Where counters are provided, provide at least one that is, on both the visitor and detainee side, at least 30 inches long and no more than 36 inches high, with knee space and clear floor space provided under the counter.  Where solid partitions or security glazing separate visitors from detainees, at least one of each type shall have a method to facilitate voice communication. 

36 months

166

Visitation

Interview Rooms

206.5, 305, 308, 309.4, 404.2.3, 404.3.1.

The interview room doors have a clear width opening of 29 inches.

Provide a door that has at least one active leaf with a clear opening at least 32 inches wide when measured from the face of the door to the edge of the other door when one door is opened 90 degrees OR provide an automatic opener that opens both doors simultaneously, even with the power off.  Automatic door opener operating devices shall be easy to operate with one hand; shall not require tight grasping, pinching, or twisting of the wrist to operate; shall not require more than 5 pounds of force to operate; shall be mounted between 15 and 48 inches high on an accessible route; and shall be accompanied by a clear floor space that is 48 inches by 30 inches and is beyond the arc of the door’s swing.

36 months

167

Visitation

Visitor's Toilet Room; Men's and Women's

206.5, 404.2.9

The doors for both the men's and women's toilet rooms require 10 pound of force to operate.

Provide a door that requires no more than 5 pounds of force to open (not including the initial force needed to overcome inertia, retracting bolts, etc.).

6 months

168

213.3.4, 306, 606.2, 606.3

The apron of the lavatory is 26 inches above the finished floor.

Provide a lavatory with the top of the rim or counter 34 inches high or less; knee clearance at least 30 inches wide, between 9 inches and 27 inches high, extending between 11 and 25 inches deep at 9 inches high, and extending at least 8 inches deep at 27 inches high; and toe clearance at least 30 inches wide and 9 inches high, and extending between 17 and 25 inches deep under the lavatory.

36 months

169

213.3.5, 603.3

The reflective surface of the mirror is mounted 49 inches above the floor.

Provide a mirror with the bottom edge of its reflectivg surface no more than 40 inches above the finished floor.

6 months

170

205.1, 305, 308.2, 308.3

The soap dispenser is mounted 49 inches above the finished foor.

Operable parts and controls of this element shall be no more than 48 inches high for a forward reach, or no more than 44 inches high if over an obstruction between 20 and 25 inches deep (for a forward reach, obstructions may not be deeper than 25 inches and obstructions must allow knee space); or mounted not more than 48 inches high for a side reach, or no more than 46 inches high if over an obstruction between 10 and 24 inches deep (for a side reach, obstruction may not be deeper than 24 inches); and accompanied by clear floor space of 30 inches by 48 inches that allows a forward or parallel approach, respectively, by a person using a wheelchair.

6 months

171

213.3.1, 404, 604.8.1.2

The toilet compartment door opening is 30 inches wide.

Provide a toilet compartment door complying with § 404 except that, if the approach is to the latch side of the compartment door, clearance between the door side of the compartment and any obstruction shall be at least 42 inches.  Doors shall be located in the front partition or in the side wall or partition farthest from the toilet.  If located in the front partition, the door opening shall be at least 4 inches from the side wall or partition farthest from the toilet. Where located in the side wall or partition, the door opening shall be at least 4 inches from the front partition. The door shall be self-closing, and a door pull complying with § 404.2.7 shall be placed on both sides of the door near the latch.  Toilet compartment doors shall not swing into the minimum required compartment area.

36 months

172

205.1, 305, 308.2, 308.3

The coathook in the women's toilet compartment is mounted at 68 inches above the finish floor.  The coathook in the men's toilet compartment is mouted at 72 inches above the finished floor.

Operable parts and controls of this element shall be no more than 48 inches high for a forward reach, or no more than 44 inches high if over an obstruction between 20 and 25 inches deep (for a forward reach, obstructions may not be deeper than 25 inches and obstructions must allow knee space); or mounted not more than 48 inches high for a side reach, or no more than 46 inches high if over an obstruction between 10 and 24 inches deep (for a side reach, obstructions may not be deeper than 24 inches); and accompanied by clear floor space of 30 inches by 48 inches that allows a forward or parallel approach, respectively, by a person using a wheelchair. 

6 months

173

213.3.1, 301.1, 404, 604, 604.8.1, 609

There is no standard accessible stall provided.

Provide an accessible toilet compartment at least 60 inches wide and at least 59 inches deep (or at least 56 inches deep with a wall-mounted toilet) such that all of the compartment’s elements, including door, door hardware, toilet, size and arrangement, toe clearances, grab bars, controls, and dispensers, comply with the Standards.

36 months

174

213.3.1, 604.2, 604.8.2

The designated accessible stall is 37 1/2 inches wide.

Provide at least one ambulatory accessible compartment that is at least 60 inches deep and between 35 and 37 inches wide with a self-closing door that does not swing into the minimum 60 inch depth; with parallel side grab bars complying with § 604.5.1 and § 609; with the centerline of the toilet between 17 and 19 inches from either side wall or partition; with a door pull on each side of the door near the latch.  If the approach is to the latch side of the exterior of the compartment door, clearance between the door opening and any obstruction shall be at least 42 inches.

36 months

175

213.3.2, 604.5, 609.3.

The toilet paper dispenser is obstructing the left grfab bar.

Provide grab bars that have at least 1½ inches between the grab bar and any object projecting beside or below it and at least 12 inches between the grab bar and any object projecting above it.

6 months

176

205.1, 305, 308.2, 308.3.

The toilet seat cover dispenser is mounted 52 inches above the finished foor, behind the toilet.

Operable parts and controls of this element shall be no more than 48 inches high for a forward reach, or no more than 44 inches high if over an obstruction between 20 and 25 inches deep (for a forward reach, obstructions may not be deeper than 25 inches and obstructions must allow knee space); or mounted not more than 48 inches high for a side reach, or no more than 46 inches high if over an obstruction between 10 and 24 inches deep (for a side reach, obstruction may not be deeper than 24 inches); and accompanied by clear floor space of 30 inches by 48 inches that allows a forward or parallel approach, respectively, by a person using a wheelchair.

6 months

177

Entrance Building

Visitor's Single User Toilet Room

213.3.4, 606.3, 606.4,

The pipes are not covered or otherwise designed to protect against contact.

Provide at least 5% of all lavatories and sinks with the top of the rim or counter 34 inches high or less; knee clearance at least 30 inches wide, between 9 inches and 27 inches high, extending between 11 and 25 inches deep at 9 inches high, and extending at least 8 inches deep at 27 inches high; and toe clearance at least 30 inches wide and 9 inches high, and extending between 17 and 25 inches deep under the lavatory; water supply and drain pipes insulated or otherwise configured to protect against contact.  Provide a faucet that can be operated with no more than 5 pounds of force and can be used with one hand and without tight grasping, pinching, or twisting of the wrist (lever-operated, push-type, and electronically controlled mechanisms are examples of acceptable designs).

36 months

178

213.3.5, 603.3

The reflective surface of the mirror is mounted 42 inches above the floor.

Provide a mirror with the bottom edge of its reflectivg surface no more than 40 inches above the finished floor.

6 months

179

205.1, 305, 308.2, 308.3

The soap dispenser is mounted 52 inches above the finished foor.

Operable parts and controls of this element shall be no more than 48 inches high for a forward reach, or no more than 44 inches high if over an obstruction between 20 and 25 inches deep (for a forward reach, obstructions may not be deeper than 25 inches and obstructions must allow knee space); or mounted not more than 48 inches high for a side reach, or no more than 46 inches high if over an obstruction between 10 and 24 inches deep (for a side reach, obstruction may not be deeper than 24 inches); and accompanied by clear floor space of 30 inches by 48 inches that allows a forward or parallel approach, respectively, by a person using a wheelchair.

6 months

180

205.1, 305, 308.2, 308.3

The paper towel dispenser is mounted 55 inches above the finished foor.

Operable parts and controls of this element shall be no more than 48 inches high for a forward reach, or no more than 44 inches high if over an obstruction between 20 and 25 inches deep (for a forward reach, obstructions may not be deeper than 25 inches and obstructions must allow knee space); or mounted not more than 48 inches high for a side reach, or no more than 46 inches high if over an obstruction between 10 and 24 inches deep (for a side reach, obstruction may not be deeper than 24 inches); and accompanied by clear floor space of 30 inches by 48 inches that allows a forward or parallel approach, respectively, by a person using a wheelchair.

6 months

181

205.1, 305, 308.2, 308.3

The toilet seat cover dispenser is mounted 63 inches above the finished foor, behind the toilet.

Operable parts and controls of this element shall be no more than 48 inches high for a forward reach, or no more than 44 inches high if over an obstruction between 20 and 25 inches deep (for a forward reach, obstructions may not be deeper than 25 inches and obstructions must allow knee space); or mounted not more than 48 inches high for a side reach, or no more than 46 inches high if over an obstruction between 10 and 24 inches deep (for a side reach, obstruction may not be deeper than 24 inches); and accompanied by clear floor space of 30 inches by 48 inches that allows a forward or parallel approach, respectively, by a person using a wheelchair.

6 months

182

213.3.2, 309.4, 604.6

The flush control is mounted on the closed side of the toilet.

Provide a flush control mounted on the “open” side of the toilet’s clear floor space, between 15 and 48 inches high, and requiring a maximum of 5 pounds of force to operate; or provide an automatic flush device.

6 months

183

213.3.2, 604.5, 609.3

The side grab bar is obstructed by toilet paper dispenser.

Provide grab bars that have at least 1½ inches between the grab bar and any object projecting beside or below it and at least 12 inches between the grab bar and any object projecting above it.

6 months

 

Table: Waiawa Correctional Facility

No

Location

2010 Standards Citations

Violations

Requirement/Action Required

Completion Date

184

Administrative Building

Men's Toilet Room

213.3.4, 606.3, 606.4,

The pipes are not covered or otherwise designed to protect against contact.

Provide a lavatory with the water and supply drain pipes are insulated or otherwise configured to protect against contact.

6 months

185

213.3.2, 309.4, 604.6

The flush control is mounted on the closed side of the toilet.

Provide a flush control mounted on the “open” side of the toilet’s clear floor space, between 15 and 48 inches high, and requiring a maximum of 5 pounds of force to operate; or provide an automatic flush device.

6 months

186

213.3.2, 604.4

The toilet seat is 16 inches above the floor.

Provide a toilet with the top of the seat 17 to 19 inches high.  The seat shall not be sprung to return to a lifted position.

6 months

187

213.3.2, 604.2

The centerline of the toilet is 24 inches from the side wall.

Provide a toilet with its centerline between 16 and 18 inches from the near side wall.

6 months

188

213.3.2, 604.7, 609.3

The toilet paper dispenser is located 4 inches in front of the water closet.

Provide a toilet paper dispenser that is mounted with its centerline between 7 and 9 inches from the front of the toilet and with its outlet between 15 and 48 inches high with continuous paper flow that does not control delivery.  The dispenser shall be mounted either at least 1½ inches below the side grab bar or at least 12 inches above the side grab bar. 

3 months

189

Administrative Building

Women's Toilet Room

213.3.2, 604.4

The toilet seat is 16 inches above the floor.

Provide a toilet with the top of the seat 17 to 19 inches high.  The seat shall not be sprung to return to a lifted position.

6 months

190

213.3.2, 604.2

The centerline of the toilet is 22 inches from the side wall.

Provide a toilet with its centerline between 16 and 18 inches from the near side wall.

6 months

191

213.3.2, 604.7, 609.3

The toilet paper dispenser is located 4 inches in front of the water closet.

Provide a toilet paper dispenser that is mounted with its centerline between 7 and 9 inches from the front of the toilet and with its outlet between 15 and 48 inches high with continuous paper flow that does not control delivery.  The dispenser shall be mounted either at least 1½ inches below the side grab bar or at least 12 inches above the side grab bar. 

3 months

192

213.3.2, 604.5.2

The rear grab bar is mounted 7 inches from the centerline.

Provide a rear grab bar that is at least 36 inches long (except where wall space does not permit it due to the location of a recessed fixture, in which case the grab bar may be 24 inches long and centered on the toilet), extending 12 inches from the toilet centerline on one side and 24 inches from the toilet centerline on the other side (except where an administrative authority requires flush controls to be located in a position that conflicts with the location of the rear grab bar, in which case the bar may be split or shifted to the open side).

6 months

193

Medical Unit

Waiting Area Toilet Room

213.3.2, 309.4, 604.6

The flush control is mounted on the closed side of the toilet.

Provide a flush control mounted on the “open” side of the toilet’s clear floor space, between 15 and 48 inches high, and requiring a maximum of 5 pounds of force to operate; or provide an automatic flush device.

6 months

194

213.3.5, 603.3

The reflective surface of the mirror is mounted 42 inches above the floor.

Provide a mirror with the bottom edge of its reflectivg surface no more than 40 inches above the finished floor.

3 months

195

213.3.2, 604.4

The toilet seat is 15 inches above the floor.

Provide a toilet with the top of the seat 17 to 19 inches high.  The seat shall not be sprung to return to a lifted position.

3 months

196

213.3.2, 604.7, 609.3

The toilet paper dispenser is located 4 inches in front of the water closet.

Provide a toilet paper dispenser that is mounted with its centerline between 7 and 9 inches from the front of the toilet and with its outlet between 15 and 48 inches high with continuous paper flow that does not control delivery.  The dispenser shall be mounted either at least 1½ inches below the side grab bar or at least 12 inches above the side grab bar. 

3 months

197

213.3.2, 604.3.

There is insufficient clearance at the toilet.

Provide clearance at the toilet that is at least 60 inches wide and 56 inches deep.  This clearance may overlap with the toilet, grab bars, dispensers, sanitary napkin disposal, coat hooks, shelves, accessible routes, clear floor space and clearances for other fixtures, and turning space; but no other fixtures or obstructions, including lavatories, may be located within this clearance.

12 months

198

Education Building

Entrance

 206.5, 305, 308, 309.4, 404.2.3, 404.3.1.

The entry door has a clear width opening of 27 inches for a single leaf.

Provide a door that has at least one active leaf with a clear opening at least 32 inches wide when measured from the face of the door to the edge of the other door when one door is opened 90 degrees OR provide an automatic opener that opens both doors simultaneously, even with the power off.  Automatic door opener operating devices shall be easy to operate with one hand; shall not require tight grasping, pinching, or twisting of the wrist to operate; shall not require more than 5 pounds of force to operate; shall be mounted between 15 and 48 inches high on an accessible route; and shall be accompanied by a clear floor space that is 48 inches by 30 inches and is beyond the arc of the door’s swing.

12 months

199

206.5, 302, 303, 404.2.5.

The entry door has a 2 inch threshold

Provide an accessible door with a threshold that is no more than ¼ inch high, or is between ¼ inch and ½ inch high (¾ inch high if the threshold is existing or altered) and is beveled with a slope no greater than 50%. 

6 months

200

Education Building

Staff and ADA Toilet Room

213.3.5, 603.3

The reflective surface of the mirror is mounted 44 inches above the floor.

Provide a mirror with the bottom edge of its reflectivg surface no more than 40 inches above the finished floor.

3 months

201

205.1, 305, 308.2, 308.3

The paper towel dispenser is mounted 54 inches above the finished floor, behind the toilet.

Operable parts and controls of this element shall be no more than 48 inches high for a forward reach, or no more than 44 inches high if over an obstruction between 20 and 25 inches deep (for a forward reach, obstructions may not be deeper than 25 inches and obstructions must allow knee space); or mounted not more than 48 inches high for a side reach, or no more than 46 inches high if over an obstruction between 10 and 24 inches deep (for a side reach, obstruction may not be deeper than 24 inches); and accompanied by clear floor space of 30 inches by 48 inches that allows a forward or parallel approach, respectively, by a person using a wheelchair.

3 months

202

213.3.2, 604.2

The centerline of the toilet is 15 inches from the side wall.

Provide a toilet with its centerline between 16 and 18 inches from the near side wall.

6 months

203

213.3.2, 604.7, 609.3

The toilet paper dispenser is located 6 inches in front of the water closet.

Provide a toilet paper dispenser that is mounted with its centerline between 7 and 9 inches from the front of the toilet and with its outlet between 15 and 48 inches high with continuous paper flow that does not control delivery.  The dispenser shall be mounted either at least 1½ inches below the side grab bar or at least 12 inches above the side grab bar. 

3 months

204

213.3.2, 604.5.2

The rear grab bar is mounted with the short end  8 inches from the centerline.

Provide a rear grab bar that is at least 36 inches long (except where wall space does not permit it due to the location of a recessed fixture, in which case the grab bar may be 24 inches long and centered on the toilet), extending 12 inches from the toilet centerline on one side and 24 inches from the toilet centerline on the other side (except where an administrative authority requires flush controls to be located in a position that conflicts with the location of the rear grab bar, in which case the bar may be split or shifted to the open side).

6 months

205

 Library

226, 305, 306, 902

The desks have 26 inches of knee space width.

At least 5% (but no fewer than 1) of work surfaces shall be available for use by people with mobility disabilities.  Each accessible surface shall be on an accessible route; with clear floor space 30 inches wide by 48 inches deep positioned for a forward approach; with toe clearance extended 17 inches minimum under the element; with knee clearance at least 11 inches deep at 9 inches high and at least 8 inches deep at 27 inches high; and with a work surface between 28 inches and 34 inches high.  They shall be distributed throughout the facility, if applicable.

6 months

206

 Dining Room

226, 305, 306, 902

None of the tables in the dining room are accessible.

At least 5% (but no fewer than 1) of dining shall be available for use by people with mobility disabilities.  Each accessible dining surface shall be on an accessible route; with clear floor space 30 inches wide by 48 inches deep positioned for a forward approach; with toe clearance extended 17 inches minimum under the element; with knee clearance at least 11 inches deep at 9 inches high and at least 8 inches deep at 27 inches high; and with a dining surface between 28 inches and 34 inches high.  They shall be distributed throughout the facility, if applicable.

6 months

207

 Visitor and Classroom, Unit's 9 & 10

206.2, 405, 505

The ramp at the entrance into the building is noncomplaint.

Provide a ramp that is at least 36 inches wide between handrails, with a slope not exceeding 8.33% and a cross slope not exceeding 2.08%; with level landings at least as wide as the ramp and 60 inches long at the top and bottom of every ramp run; with level landings at least 60 inches by 60 inches when the ramp changes direction; and with no changes in level other than the slope and cross-slope.  The ramp shall have no run containing a rise greater than 30 inches.  On each side of ramp runs and landings, provide edge protection that consists of either an extended ground surface at least 12 inches beyond the edge of the surface of the ramp or landing, or a curb or barrier that prevents the passage of a 4 inch diameter sphere where any part of the sphere is within 4 inches of the surface.  On both sides of ramps with rises greater than 6 inches, provide handrails that have a diameter between 1¼ and 2 inches or a perimeter between 4 inches and 6¼ inches and a cross section of no more than 2¼ inches such that the handrails are continuous along the full length of the ramp run.  Inside handrails on switchbacks or doglegs shall be continuous between runs; handrails shall have a continuous gripping surface extending at least 12 inches beyond the top and bottom of the ramp parallel with the ground surface; extensions shall return to the wall, guard, or landing surface (or continue on as handrails); handrails shall not rotate within their fittings; handrails shall be mounted at a consistent height between 34 inches and 38 inches above the ramp surface and at least 1½ inches from the wall; gripping surfaces and adjacent surfaces shall be free of sharp or abrasive elements and have rounded edges; and gripping surfaces shall not be obstructed along their tops or sides and the bottoms shall not be obstructed for more than 20% of their length and have no horizontal projections occurring closer than 1½ inches from the bottom of the gripping surface (except that the distance between horizontal projections and the bottom of the gripping surface can be reduced by ⅛ inch for each ½ inch of handrail perimeter over 4 inches).  If the ramp is subject to wet conditions, landings shall be designed to prevent the accumulation of water. 

12 months

208

Building 9

Side A

Shower

2.13.3.6, 608.2.1, 610

The shower compartment is 36 inches by 40 inches.

The shower compartment shall be 36 inches by 36 inches, the entrance shall be at least 36 inches wide, and clearance adjacent to the opening shall be 36 inches wide by 48 inches long measured from the control wall (so that the clearance extends beyond the seat).

12 months

209

Building 9

Side A

Toilet Room

28 C.F.R. § 35.133

The lower urinal is not operational.

Maintain this feature in operable working condition.

12 months

210

213.3.5, 603.3

The reflective surface of the mirror is mounted 41 inches above the floor.

Provide a mirror with the bottom edge of its reflectivg surface no more than 40 inches above the finished floor.

3 months

211

213.3.2, 604.4

The toilet seat is 15 inches above the floor.

Provide a toilet with the top of the seat 17 to 19 inches high.  The seat shall not be sprung to return to a lifted position.

6 months

212

213.3.2, 604.7, 609.3

The toilet paper dispenser is located 6 inches in front of the water closet.

Provide a toilet paper dispenser that is mounted with its centerline between 7 and 9 inches from the front of the toilet and with its outlet between 15 and 48 inches high with continuous paper flow that does not control delivery.  The dispenser shall be mounted either at least 1½ inches below the side grab bar or at least 12 inches above the side grab bar. 

3 months

213

Building 9

Side B

Shower

2.13.3.6, 608.2.1, 610

The shower compartment is 36 inches by 40 inches.

The shower compartment shall be 36 inches by 36 inches, the entrance shall be at least 36 inches wide, and clearance adjacent to the opening shall be 36 inches wide by 48 inches long measured from the control wall (so that the clearance extends beyond the seat).

12 months

214

Building 9

Side B

Toilet Room

213.3.3, 305, 308.2, 309.4, 605

The height of the urinal rim is 20 inches above the finished floor.

Provide a stall-type or a wall-hung urinal with a rim mounted 17 inches high or less; a depth of at least 13½ inches from the outer face to the rear of the urinal; a clear floor space at least 30 inches wide and 48 inches deep positioned for a forward approach; and a flush control between 15 and 48 inches high or an automatic flush. 

12 months

215

213.3.5, 603.3

The reflective surface of the mirror is mounted 41 inches above the floor.

Provide a mirror with the bottom edge of its reflectivg surface no more than 40 inches above the finished floor.

3 months

216

213.3.2, 604.4

The toilet seat is 15 inches above the floor.

Provide a toilet with the top of the seat 17 to 19 inches high.  The seat shall not be sprung to return to a lifted position.

6 months

217

213.3.2, 604.7, 609.3

The toilet paper dispenser is located 6 inches in front of the water closet.

Provide a toilet paper dispenser that is mounted with its centerline between 7 and 9 inches from the front of the toilet and with its outlet between 15 and 48 inches high with continuous paper flow that does not control delivery.  The dispenser shall be mounted either at least 1½ inches below the side grab bar or at least 12 inches above the side grab bar. 

3 months

218

Route between Building 9 and 10

206, 307

The drinking fountains protrudes into the accessible walkway.

Unless protected by a cane detectable barrier, objects with their leading edges between 27 inches and 80 inches high shall not protrude into circulation paths more than 4 inches for wall-mounted elements, or 12 inches for free standing post- or pylon-mounted elements.  Protruding objects (and cane-detectable barriers) shall not reduce the clear width of accessible routes or maneuvering spaces below minimum requirements. 

6 months

219

Building 9

Side A

Shower

2.13.3.6, 608.2.1, 610

The shower compartment is 36 inches by 40 inches.

The shower compartment shall be 36 inches by 36 inches, the entrance shall be at least 36 inches wide, and clearance adjacent to the opening shall be 36 inches wide by 48 inches long measured from the control wall (so that the clearance extends beyond the seat).

12 months

220

Building 9

Side A

Toilet Room

213.3.3, 305, 308.2, 309.4, 605

The height of the urinal rim is 20 inches above the finished floor.

Provide a stall-type or a wall-hung urinal with a rim mounted 17 inches high or less; a depth of at least 13½ inches from the outer face to the rear of the urinal; a clear floor space at least 30 inches wide and 48 inches deep positioned for a forward approach; and a flush control between 15 and 48 inches high or an automatic flush. 

12 months

221

213.3.5, 603.3

The reflective surface of the mirror is mounted 41 inches above the floor.

Provide a mirror with the bottom edge of its reflectivg surface no more than 40 inches above the finished floor.

3 months

222

213.3.2, 604.4

The toilet seat is 15 inches above the floor.

Provide a toilet with the top of the seat 17 to 19 inches high.  The seat shall not be sprung to return to a lifted position.

6 months

223

213.3.2, 604.7, 609.3

The toilet paper dispenser is located 6 inches in front of the water closet.

Provide a toilet paper dispenser that is mounted with its centerline between 7 and 9 inches from the front of the toilet and with its outlet between 15 and 48 inches high with continuous paper flow that does not control delivery.  The dispenser shall be mounted either at least 1½ inches below the side grab bar or at least 12 inches above the side grab bar. 

3 months

224

Building 9

Side B

Shower

2.13.3.6, 608.2.1, 610

The shower compartment is 36 inches by 40 inches.

The shower compartment shall be 36 inches by 36 inches, the entrance shall be at least 36 inches wide, and clearance adjacent to the opening shall be 36 inches wide by 48 inches long measured from the control wall (so that the clearance extends beyond the seat).

12 months

225

Building 9

Side B

Toilet Room

213.3.3, 305, 308.2, 309.4, 605

The height of the urinal rim is 20 inches above the finished floor.

Provide a stall-type or a wall-hung urinal with a rim mounted 17 inches high or less; a depth of at least 13½ inches from the outer face to the rear of the urinal; a clear floor space at least 30 inches wide and 48 inches deep positioned for a forward approach; and a flush control between 15 and 48 inches high or an automatic flush. 

12 months

226

213.3.5, 603.3

The reflective surface of the mirror is mounted 41 inches above the floor.

Provide a mirror with the bottom edge of its reflectivg surface no more than 40 inches above the finished floor.

3 months

227

213.3.2, 604.4

The toilet seat is 15 inches above the floor.

Provide a toilet with the top of the seat 17 to 19 inches high.  The seat shall not be sprung to return to a lifted position.

6 months

228

213.3.2, 604.7, 609.3

The toilet paper dispenser is located 6 inches in front of the water closet.

Provide a toilet paper dispenser that is mounted with its centerline between 7 and 9 inches from the front of the toilet and with its outlet between 15 and 48 inches high with continuous paper flow that does not control delivery.  The dispenser shall be mounted either at least 1½ inches below the side grab bar or at least 12 inches above the side grab bar. 

3 months

229

Building 11

206.5, 302, 303, 404.2.5.

The entry door has a 4 inch threshold.

Provide an accessible door with a threshold that is no more than ¼ inch high, or is between ¼ inch and ½ inch high (¾ inch high if the threshold is existing or altered) and is beveled with a slope no greater than 50%. 

6 months