Rabb | |||||||
Barrier # New | Building Name | Room No. | Space Name | Item / Component | Barriers | ADA Standards and Regulations | BIDMC Action to Comply with the ADA |
---|---|---|---|---|---|---|---|
385 | Rabb | 1st floor | Gastroenterology | counter | not accessible | 4.1.6(1)(b), 4.1.1(2), 7.2(2) | install compliant counter or add auxiliary counter |
386 | Rabb | RA-0205 | Psychiatry/Social
Services Registration/ Waiting room |
signage | no signage on latch side | 4.1.6(1)(b),
4.1.3(16), 4.30.6 |
install signage |
387 | Rabb | RA-0205 | Psychiatry/Social
Services Registration/ Waiting room |
door hardware | inaccessible hardware | 4.1.6(1)(b), 4.1.3(7), 4.13.9, 4.27.4 | replace with accessible hardware |
388 | Rabb | RA-0205 | Psychiatry/Social
Services Registration/ Waiting room |
hook | above reach range | 4.1.6(1)(b), 4.1.3(12)(a), 4.25.3 | reposition or add hook |
389 | Rabb | RA-0205 | Psychiatry/Social
Services Registration/ Waiting room |
counter | mounted too high | 4.1.6(1)(b), 4.1.1(2), 7.2(2) | Install compliant counter or add auxiliary counter |
390 | Rabb | RA-206 | Men's Toilet Room | flush control | control on wrong side | 4.1.3(11), 4.22.4, 4.16.5 | reposition or install automatic flush control |
391 | Rabb | RA-206 | Men's Toilet Room | urinal | mounted too high | 4.1.6(1)(b), 4.1.3(11), 4.22.5, 4.18.2 | provide accessible urinal |
392 | Rabb | RA-206 | Men's Toilet Room | urinal flush control | high | 4.1.6(1)(b),
4.1.3(11),
4.22.5, 4.18.4 |
reposition |
393 | Rabb | RA-206 | Men's Toilet Room | toilet paper dispenser | incorrect placement | 4.1.6(1)(b), 4.1.3(11), 4.22.4, 4.22.7, 4.16.6 |
reposition |
394 | Rabb | RA-206 | Men's Toilet Room | mirror | mounted too high | 4.1.6(1)(b), 4.1.3(11), 4.22.6, 4.19.6 | reposition or install full length mirror |
395 | Rabb | RA-206 | Men's Toilet Room | hook | above reach range | 4.1.6(1)(b), 4.1.3(12)(a), 4.25.3 | reposition or add hook |
396 | Rabb | 2nd floor | Hall to elevator | door hardware | inaccessible hardware | 4.1.6(1)(b), 4.1.3(7), 4.13.9, 4.27.4 | replace with accessible hardware |
397 | Rabb | 2nd floor | Elevator lobby | telephone | above reach range | 4.1.6(1)(b), 4.1.3(17), 4.31.3 | provide accessible house phone and directional signage |
398 | Rabb | 2nd floor | Women's toilet room | dispenser - feminine product | protruding object | 4.1.6(1)(b), 4.1.3(2), 4.4.1 | install cane-detectable warning |
399 | Rabb | 2nd floor | Women's toilet room | door | door opening forced too high | 4.1.6(1)(b), 4.1.3(7), 4.13.11(2)(b) | remove/adjust closer |
400 | Rabb | RA-0B34 | Radiation Oncology Exam Room Suite | hook | above reach range | 4.1.6(1)(b), 4.1.3(12)(a), 4.25.3 | reposition or add hook |
1. Per paragraph 20 of the Settlement
Agreement, corrective measures to newly constructed facilities noted herein
shall comply fully with the New Construction provisions of the ADA, 42 U.S.C.
§ 12183(a), 28 C.F.R. §§ 36.401 & 406 including the ADA Standards for
Accessible Design, Appendix A. 2. Per paragraph 21 of the Settlement Agreement, corrective measures to altered or existing facilities noted herein shall comply fully with the Alterations provisions of the ADA, 42 U.S.C. § 12183(a)(2), 28 C.F.R. §§ 36.402 - 406 including the ADA Standards for Accessible Design, Appendix A. 3. ADA Standards for Accessible Design define medical care facilities as those in which people receive physical or medical treatment or care and where persons may need assistance in responding to an emergency and where the period of stay may exceed twenty-four hours. In addition to the requirements of 4.1 through 4.35, medical care facilities and buildings shall comply with 6. |