Barrier # New | Building Name | Room No. | Space Name | Item / Component | Barriers | ADA Standards and Regulations | BIDMC Action to Comply with the ADA |
---|---|---|---|---|---|---|---|
81 | Deaconess | DE-1 | Elevator outside Psychiatry Office | signage | No raised lettering on hoist way | 4.1.6(1)(b), 4.1.3(5), 4.10.5 | add raised and Braille lettering |
82 | Deaconess | DE-1 | Elevator outside Psych Office | signage | No raised lettering on hoist way | 4.1.6(1)(b), 4.1.3(5), 4.10.5 | add raised and Braille lettering |
83 | Deaconess | DE-1 | Employee Occupational Health Service | counter | mounted too high | 4.1.6(1)(b), 4.1.1(2), 7.2(2) | install complaint counter or add auxiliary counter |
84 | Deaconess | 1st Floor | Hall | fire extinguisher case - handle | above reach range | 4.1.6(1)(b), 4.1.3(12)(a), 4.25 | reposition |
85 | Deaconess | DE-0202 | toilet room | toilet paper dispenser | incorrect placement | 4.1.6(1)(b), 4.1.3(11), 4.22.4, 4.22.7, 4.16.6 |
reposition |
86 | Deaconess | DE-0202 | toilet room | hook | above reach range | 4.1.6(1)(b), 4.1.3(12)(a), 4.25.3 | reposition or add hook |
87 | Deaconess | DE-0202 | toilet room | signage | mounted incorrectly | 4.1.6(1)(b),
4.1.3(16), 4.30.6 |
reposition |
88 | Deaconess | DE-0206 | Unisex Accessible toilet room | side grab bar | incorrect length | 4.1.6(1)(b), 4.1.3(11), 4.22.4, 4.16.4 | install compliant grab bar |
89 | Deaconess | DE-0206 | Unisex Accessible toilet room | signage | mounted incorrectly | 4.1.6(1)(b),
4.1.3(16), 4.30.6 |
reposition |
90 | Deaconess | DE-0206 | Unisex Accessible toilet room | hook | above reach range | 4.1.6(1)(b), 4.1.3(12)(a), 4.25.3 | reposition or add hook |
91 | Deaconess | DE-0206 | Unisex Accessible toilet room | flush control | control on wrong side | 4.1.6(1)(b), 4.1.3(11), 4.22.4, 4.16.5 | reposition or install automatic flush control |
92 | Deaconess | DE-0206 | Unisex Accessible toilet room | lavatory | exposed/uninsulated pipes | 4.1.6(1)(b), 4.1.3(11), 4.22.6, 4.19.4 | insulate or configure to protect against contact |
93 | Deaconess | DE-0207 | Pulmonary Special Procedures unit | counter | mounted too high | 4.1.6(1)(b), 4.1.1(2), 7.2(2) | install complaint counter or add auxiliary counter |
94 | Deaconess | DE-0207 | Pulmonary Special Procedures unit | telephone shelf in hall | protruding object | 4.1.6(1)(b), 4.1.3(2), 4.4.1 | relocate/remove shelf |
95 | Deaconess | Outside DE-319 | toilet room | toilet centerline | centerline too far from wall | 4.1.6(1)(b),
4.1.3(11),
4.22.4, 4.16.2 |
provide offset flange and/or sidewall build out |
96 | Deaconess | Outside DE-319 | toilet room | toilet paper dispenser | incorrect placement | 4.1.6(1)(b), 4.1.3(11), 4.22.4, 4.22.7, 4.16.6 |
reposition |
97 | Deaconess | Outside DE-319 | toilet room | paper towel dispenser | protruding object | 4.1.6(1)(b), 4.1.3(2), 4.4.1 | reposition
or install cane-detectable warning |
98 | Deaconess | DEAC 403T | Psychiatric Unit- Bathroom | flush control | control on wrong side | 4.1.6(1)(b), 4.1.3(11), 4.23.4, 4.16.5 | reposition or install automatic flush control |
99 | Deaconess | DEAC 403T | Psychiatric Unit- Bathroom | side grab bar | incorrect length | 4.1.6(1)(b), 4.1.3(11), 4.23.4, 4.16.4 | install compliant grab bar |
100 | Deaconess | DEAC 403T | Psychiatric Unit- Bathroom | side grab bar | incorrect height | 4.1.6(1)(b), 4.1.3(11), 4.23.4, 4.16.4 | reposition |
101 | Deaconess | DEAC 403T | Psychiatric Unit- Bathroom | rear grab bar | incorrect height | 4.1.6(1)(b), 4.1.3(11), 4.23.4, 4.16.4 | reposition |
102 | Deaconess | DEAC 407 | Psychiatric Unit private room with toilet room | door | inadequate passage width | 4.1.6(1)(b), 4.1.3(7), 4.13.5 | provide accessible patient room |
103 | Deaconess | DEAC 407 | Psychiatric Unit private room with toilet room | turning space | inadequate clear floor space | 4.1.6(1)(b), 4.1.3(11), 6.1, 6.1(1), 6.3, 6.4, 4.22.3 |
provide accessible patient room with accessible toilet room |
104 | Deaconess | DEAC 407A | Psychiatric Unit- Bathroom | shower dimensions | incorrect dimensions | 4.1.6(1)(b), 4.1.3(11), 6.1, 6.1(1), 6.4, 4.23.8, 4.21.2 |
provide accessible patient room with accessible shower |
105 | Deaconess | DEAC 407A | Psychiatric Unit- Bathroom | side grab bar | incorrect length | 4.1.6(1)(b), 4.1.3(11), 4.23.4, 4.16.4 | install compliant grab bar |
106 | Deaconess | 4th Floor | Psychiatric Unit | patient bedrooms and toilets | Insufficient number of patient bedrooms and toilets | 4.1.6(1)(B), 6.1(1), 6.3, 6.4 |
provide accessible patient room |
1. Per paragraph 20 of the Settlement
Agreement, corrective measures to newly constructed facilities noted herein
shall comply fully with the New Construction provisions of the ADA, 42 U.S.C.
§ 12183(a), 28 C.F.R. §§ 36.401 & 406 including the ADA Standards for
Accessible Design, Appendix A. 2. Per paragraph 21 of the Settlement Agreement, corrective measures to altered or existing facilities noted herein shall comply fully with the Alterations provisions of the ADA, 42 U.S.C. § 12183(a)(2), 28 C.F.R. §§ 36.402 - 406 including the ADA Standards for Accessible Design, Appendix A. 3. ADA Standards for Accessible Design define medical care facilities as those in which people receive physical or medical treatment or care and where persons may need assistance in responding to an emergency and where the period of stay may exceed twenty-four hours. In addition to the requirements of 4.1 through 4.35, medical care facilities and buildings shall comply with 6. |
|||||||
Cases & Matters by ADA Title Coverage | Legal Documents by Type & Date | archive.ADA.gov Home Page