ATTACHMENT I: Program Access in Existing Facilities The technical requirements and, where appropriate, the scoping requirements of the Standards are used as a guide for determining whether a program or activity held in an existing facility is “readily accessible to and usable by” persons with disabilities and for determining what changes are necessary to make this program or activity accessible if it continues to be provided in the existing facility in question. See 28 C.F.R. §§ 35.150(b)(1), 35.151. The chart below lists the facilities surveyed by the Department, the access issues identified during the survey, and the actions required to correct the access issues. Required actions are listed using an alphanumeric code. The key to the alphanumeric codes is provided in Attachment J to this Agreement. In order to ensure that the programs, services, and activities housed in the County’s facilities are accessible to persons with disabilities, when viewed in their entirety, Washington County, Missouri will take the actions referenced by the alphanumeric code and described in detail in Attachment J to this Settlement Agreement within the time period specified below, which time period begins to run on the effective date of this Agreement. |
|||
Item # |
Access Issue |
Required Action |
Completion Date |
---|---|---|---|
1. |
Washington County Courthouse, located at 102 N. Missouri Street |
||
1.1 |
Rear parking lot: The parking lot, with a total of 17 parking spaces, is inaccessible because the designated accessible parking space has a slope of 5.8%, the access aisle has a cross slope of 4.3%, and there is no vertical signage. This lot requires one van accessible space. |
P1 |
6 months |
1.2. |
Entrance |
||
1.2.1. |
The route from the parking area to the entrance is inaccessible because there is a slope of 7.4% leading to the entrance and there are no handrails provided. |
AR1 |
6 months |
1.2.2 |
The building does not have directional signage posted at inaccessible entrances and does not have the International Symbol of Accessibility posted at accessible entrances. |
D10 |
6 months |
1.2.3 |
The interior ramp is inaccessible because it has a slope of 24.1%, it lacks compliant handrails, it has no edge protection, and it has no level landing at the bottom. |
R1 |
6 months |
1.3 |
Interior signage: The signage provided throughout the facility is inaccessible because it is mounted on or above the doors and does not have raised and Braille characters. |
D15 |
6 months |
1.4 |
Associate / Circuit Court / Probate Courtroom |
||
1.4.1 |
The door is inaccessible because knob hardware is used. |
D2 |
30 months |
1.4.2 |
The pull side of the door, which is accessed through a front approach, is inaccessible because a chair obstructs the clear space on the latch side. |
D5 |
6 months |
1.4.3 |
The table is inaccessible because it provides 24 inches of clear knee height. |
DW1 |
30 months |
1.4.4 |
The route to the front of the room, including the witness stand, is inaccessible because it is only 28 inches wide past the corner of the table. |
AR3 |
30 months |
1.5 |
Circuit Clerk’s office |
||
1.5.1 |
The door is inaccessible because it has an opening width of 29 1/2 inches. |
D14 |
30 months |
1.5.2 |
The computer station is inaccessible because the keyboard is on a counter 50 inches high. |
C2 |
6 months |
1.6 |
1st floor designated accessible single user toilet room: The toilet room contains a number of inaccessible elements and is not accessible to people with disabilities. |
TR1 |
30 months |
1.7 |
1st floor drinking fountain |
||
1.7.1 |
The drinking fountain is inaccessible because it has a spout that is 40 inches high. |
DF3 |
6 months |
1.7.2 |
The drinking fountain is inaccessible because its control requires 7 pounds of force to operate. |
DF2 |
6 months |
1.8 |
Routes to 2nd floor and basement: There is no access to upper and lower levels of the facility for people with mobility impairments. |
AR8 |
6 months |
1.9 |
2nd floor Circuit Court |
||
1.9.1 |
The door is inaccessible because there is a slope of 5% within the door’s required maneuvering clearance. |
D7 |
30 months |
1.9.2 |
The door is inaccessible because it requires 13 pounds of force to open. |
D3 |
30 months |
1.9.3 |
The witness stand is inaccessible because it can be accessed only by steps. |
AA8 |
30 months |
1.9.4 |
The jury box is inaccessible because there is no clear floor space to allow a wheelchair into the jury box. |
AA8 |
30 months |
1.9.5 |
There is no signage informing the public of the availability of an assistive listening system. |
AA3 |
30 months |
1.10 |
2nd floor single user toilet rooms: The toilet rooms contain a number of inaccessible elements and are not accessible to people with disabilities. |
TR1 |
30 months |
1.11 |
2nd floor drinking fountain: The drinking fountain is inaccessible because it has a spout that is 40 inches high. |
DF3 |
6 months |
1.12 |
Route in basement: The fire extinguisher near the real estate office protrudes into the walkway and is not detectable to blind persons using a cane. |
AR7 |
6 months |
1.13 |
Real Estate office |
||
1.13.1 |
The door is inaccessible because it has an opening width of 30 inches. |
D14 |
30 months |
1.13.2 |
The computer station is inaccessible because it provides insufficient clear knee space. |
C2 |
30 months |
1.14 |
Map room: The door is inaccessible because it has an opening width of 29 1/2 inches. |
D14 |
30 months |
1.15 |
Recorder of Deeds |
||
1.15.1 |
The door is inaccessible because it has an opening width of 29 1/2 inches |
D14 |
30 months |
1.15.2 |
The door is inaccessible because knob hardware is used. |
D2 |
30 months |
1.15.3 |
The pull side of the door, which is accessed through a front approach, is inaccessible because it has only 15 inches of clear space on the latch side. |
D5 |
30 months |
1.16 |
Basement men’s and women’s toilet rooms: The toilet rooms contain a number of inaccessible elements and are not accessible to people with disabilities. |
TR1 |
30 months |
2. |
Washington County Juvenile Court and Extension Office, located at 113 N. Missouri Street |
||
2.1 |
Entrance: The door is inaccessible because thumb latch hardware is used. |
D2 |
30 months |
2.2 |
Interior doors: The interior doors throughout the facility are inaccessible because knob hardware is used. |
D2 |
30 months |
2.3 |
Single-user unisex toilet room |
||
2.3.1 |
The toilet room sign is mounted on the door. |
TR11 |
30 months |
2.3.2 |
Although an audible alarm is provided in this facility, there is no visual alarm appliance in the toilet room. |
AL1 |
30 months |
2.3.3 |
No accessible mirror has been provided. |
TR5 |
30 months |
2.3.4 |
The toilet is inaccessible because the flush control is on the closed side. |
TR4 |
30 months |
2.3.5 |
The toilet paper dispenser is inaccessible because it is mounted 45 inches from the rear wall. |
TR6 |
30 months |
2.3.6 |
The toilet is inaccessible because the side grab bar is mounted 32 inches above the finished floor. |
TR19 |
30 months |
2.3.7 |
The toilet is inaccessible because there is no rear grab bar provided. |
TR13 |
30 months |
2.3.8 |
The toilet is inaccessible because there is insufficient clear floor space provided. |
TR24 |
30 months |
3. |
Washington County Sheriff's Office, located at 116 West High Street |
||
3.1 |
Parking |
||
3.1.1 |
The designated accessible parking is inaccessible because the signs are mounted too low and there is no “van accessible” sign. |
P3 |
6 months |
3.1.2 |
The designated accessible parking is inaccessible because it has a slope of 3.3%. |
P4 |
30 months |
3.2 |
Route from parking to entrance: The route is inaccessible because it has a slope of up to 9% and a cross slope of up to 5.3%. |
AR1 |
30 months |
3.3 |
Entrance |
||
3.3.1 |
The door is inaccessible because it has an opening width of 30 inches. |
D14 |
30 months |
3.3.2 |
The door is inaccessible because there is a 1 1/4 inch high threshold. |
D23 |
30 months |
3.3.3 |
The door is inaccessible because knob hardware is used. |
D2 |
30 months |
3.3.4 |
The pull side of the door, which is accessed through a front approach, is inaccessible because the clear space on the latch side is obstructed by a bench. |
D5 |
30 months |
3.4 |
Lobby counter: The counter is inaccessible because it is 41 inches high. |
C6 |
12 months |
3.5 |
Toilet in intake cell: The toilet room contains a number of inaccessible elements and is not accessible to people with disabilities. |
TR1 |
30 months |
3.6 |
Interview room: The interview room contains a number of inaccessible elements and is not accessible to people with disabilities. |
PJ7 |
30 months |