ATTACHMENT I: Modifications to Newly Constructed Facilities

Please Note: Paragraph 32 of the Settlement Agreement requires that within three months of the effective date of this Agreement, the Town provide signage as necessary to comply with 28 C.F.R. 35.1 § 63(b), after having surveyed all facilities that are the subject of this Agreement for the purpose of identifying those that have multiple entrances not all of which are accessible.

The chart below lists the facilities surveyed by the Department, the access issues identified during the survey, and the actions required to correct the access issues. Required actions are listed using an alphanumeric code. The key to the alphanumeric codes is provided in Attachment M to this Agreement.

In order to ensure that the following spaces and elements in Town facilities for which construction was commenced after January 26, 1992, are readily accessible to and usable by persons with disabilities, the Town will take the actions referenced by the alphanumeric code and described in detail in Attachment M to this Settlement Agreement within the time periods specified below, which time periods will begin to run on the effective date of this Agreement.

Item #

Access Issue

Required Action

Completion Date

1

 

EVA WALKER PARK, located at 105 Alexandria Pike

 

 

1.1

 

Exterior Accessible Route

 

 

1.1.a

 

The route from the street into the park is inaccessible because the curb ramp has a cross slope of 8.4%.

AR5

18 months

1.1.b

 

The route to the basketball court is inaccessible because it contains steps.

AR1

18 months

1.1.c

 

The route to the play equipment is inaccessible because the grass is not firm, stable, and slip resistant.

AR1

18 months

1.1.d

 

The route to the portable toilet is inaccessible because the grass is not firm, stable, and slip resistant and the threshold is not beveled and is more than ¼ inch high.

AR1

18 months

1.2

 

Picnic Tables. The picnic tables are inaccessible because none provide the required knee space.

PD6

18 months

2

 

RADY PARK, located at 718 Fauquier Road

 

 

2.1

 

Parking. The parking lot, with a total of 58 parking spaces, is inaccessible because it only has one space designated as accessible and this space lacks vertical signage. This lot requires one van accessible space and two standard accessible spaces.

P3

18 months

2.2

 

Drinking Fountain. Although a designated accessible drinking fountain is provided, there is no drinking fountain provided for people who have difficulty bending or stooping.

DF3

18 months

2.3

 

Information Kiosk. The brochure rack by the drinking fountain is inaccessible because the bushes in front extend out 32 inches.

TR4

18 months

2.4

 

Men´s Single-User Toilet Room

 

 

2.4.a

 

The toilet room sign is mounted with its centerline 64 inches above the ground.

TR17

18 months

2.4.b

 

No accessible mirror has been provided.

TR14

18 months

2.4.c

 

The lavatory is inaccessible because it has twist-type hardware.

TR10

18 months

2.5

 

Women´s Single-User Toilet Room

 

 

2.5.a

 

The toilet room sign is mounted with its centerline 64 inches above the ground.

TR17

18 months

2.5.b

 

No accessible mirror has been provided.

TR17

18 months

2.6

 

Benches. The routes to the benches are inaccessible because the grass is not firm, stable, and slip resistant.

AR1

18 months

2.7

 

Scoop Dispenser

 

 

2.7.a

 

The scoop dispenser is inaccessible because it is mounted with the controls 62 inches above the finished floor.

TR5

18 months

2.7.b

 

The route to the scoop dispenser is inaccessible because the grass is not firm, stable, and slip resistant.

AR1

18 months

2.8

 

Picnic Tables. The picnic tables are inaccessible because none provide the required knee space.

PD6

18 months

3

 

POLICE FACILITY, located at 333 Carriage House Lane

 

 

3.1

 

Parking. The parking lot, with a total of 34 parking spaces, is inaccessible because there is no van accessible parking space, and the designated accessible parking spaces and access aisle have slopes between 3.7% and 4.6%. This lot requires one van accessible space and one standard accessible spaces.

P3

18 months

3.2

 

Women´s Lobby Single-User Toilet Room. The toilet is inaccessible because the flush control is on the closed side.

SU1

18 months

3.3

 

Men´s Lobby Single-User Toilet Room. The toilet is inaccessible because the flush control is on the closed side.

SU1

18 months

3.4

 

Training Center

 

 

3.4.a

 

The training center is inaccessible to people with hearing disabilities because there is no assistive listening system provided.

AA5

18 months

3.4.b

 

The coat rack is inaccessible because it is mounted with the coat hangers 57 inches above the finished floor.

TR5

18 months

3.4.c

 

The defibrillator protrudes into the walkway and is not detectable to blind persons using a cane.

AR8

18 months

3.4.d

 

The telephone is inaccessible because it is mounted with the controls 56 inches above the finished floor.

TR5

18 months

3.5

 

Exercise Room. The door is inaccessible because it requires 7 pounds of force to open.

D2

18 months

3.6

 

Women´s Lockers

 

 

3.6.a

 

The door is inaccessible because it requires 12 pounds of force to open.

D2

18 months

3.6.b

 

Although an audible alarm is provided in this facility, there is no visual alarm appliance in the locker room.

TR21

18 months

3.6.c

 

The toilet is inaccessible because the flush control is on the closed side.

ST2

18 months

3.6.d

 

The transfer shower is inaccessible because the clear floor space extends only 8 inches beyond the shower wall on which the seat is mounted, and the controls are mounted 20 inches from the shower opening.

B8

18 months

3.6.e

 

The bench is inaccessible because it is 9 inches deep, 36 inches long, and not attached to the wall.

LR1

18 months

3.7

 

Men´s Lockers

 

 

3.7.a

 

The door is inaccessible because it requires 13 pounds of force to open.

D2

18 months

3.7.b

 

Although an audible alarm is provided in this facility, there is no visual alarm appliance in the locker room.

TR21

18 months

3.7.c

 

The urinal is inaccessible because the rim is 24 inches above the finished floor, and the flush control is 50 inches above the finished floor.

TR20

18 months

3.7.d

 

The designated accessible toilet is inaccessible because the flush control is on the closed side.

ST2

18 months

3.7.e

 

The transfer shower is inaccessible because the controls are mounted 21 inches from the shower opening.

B8

18 months

3.7.f

 

The bench is inaccessible because it is 9½ inches deep and is not attached to the wall.

LR1

18 months

3.8

 

Drinking Fountain by Janitor´s Closet). Although a designated accessible drinking fountain is provided, there is no drinking fountain provided for people who have difficulty bending or stooping.

DF3

18 months

4

 

VISITOR´S CENTER, located at 33 N. Calhoun Street

 

 

4.1

 

Parking. The parking lot, with a total of 36 parking spaces, is inaccessible because there is no van accessible space, and the designated accessible parking spaces and access aisles by the Visitor´s Center have slopes between 7.5% and 9.3%. This lot requires one van accessible space and one standard accessible spaces.

P3

18 months

4.2

 

Entrances. The building does not have directional signage posted at inaccessible entrances and does not have the International Symbol of Accessibility posted at accessible entrances.

D16

18 months

4.3

 

Women´s Upper Level Toilet Room with Stalls

 

 

4.3.a

 

The door is inaccessible because it requires 12 pounds of force to open.

D2

18 months

4.3.b

 

Although an audible alarm is provided in this facility, there is no visual alarm appliance in the toilet room.

TR2

18 months

4.3.c

 

The toilet room door swings into the required clear floor space at the lavatory.

TR6

18 months

4.3.d

 

No accessible coat hook has been provided.

TR1

18 months

4.4

 

Men´s Upper Level Toilet Room with Stalls

 

 

4.4.a

 

The door is inaccessible because it requires 13 pounds of force to open.

D2

18 months

4.4.b

 

Although an audible alarm is provided in this facility, there is no visual alarm appliance in the toilet room.

TR2

18 months

4.4.c

 

No accessible coat hook has been provided.

TR1

18 months

4.5

 

Main Lobby. The counter is inaccessible because it is 43 inches above the finished floor.

C6

18 months

4.6

 

Lift off Main Lobby. The lift is inaccessible because it requires that a key be obtained from an employee before the lift can be operated.

LF1

18 months

4.7

 

Meeting Rooms. The meeting rooms are inaccessible to people with hearing disabilities because there is no assistive listening system provided.

AA5

18 months

4.8

 

Men´s Ground Level Single-User Toilet Room

 

 

4.8.a

 

Although an audible alarm is provided in this facility, there is no visual alarm appliance in the toilet room.

TR21

18 months

4.8.b

 

The side grab bar at the toilet is inaccessible because it is mounted with the far end 46½ inches from the rear wall.

SU6

18 months

4.9

 

Women´s Ground Level Single-User Toilet Room. Although an audible alarm is provided in this facility, there is no visual alarm appliance in the toilet room.

TR21

18 months

4.10

 

Patio Terrace. The picnic tables are inaccessible because none provide the required knee space.

PD6

18 months

5

 

WARRENTON AQUATIC AND RECREATION FACILITY, located at 800 Waterloo Road

 

 

5.1

 

Parking

 

 

5.1.a

 

The designated accessible parking is inaccessible because the spaces and access aisles have slopes between 2.5% and 4%.

P7

18 months

5.1.b

 

The van accessible parking spaces are inaccessible because they lack "Van Accessible" signage.

P6

18 months

5.1.c

 

The curb ramp by the walking trail is inaccessible because it has a cross slope of 3.7%.

AR5

18 months

5.2

 

Picnic Tables. The picnic tables are inaccessible because none provide the required knee space.

PD6

18 months

5.3

 

Second Floor Drinking Fountain across from Fitness Room. Although an accessible drinking fountain is provided, there is no drinking fountain provided for people who have difficulty bending or stooping.

DF3

18 months

5.4

 

Second Floor Toilet Rooms with Stalls. The doors are inaccessible because they require 10 pounds of force to open.

D2

18 months

5.5

 

Men´s Lower Level Locker Room by Pool

 

 

5.5.a

 

The air dryers protrude into the walkway and are not detectable to blind persons using a cane.

AR8

18 months

5.5.b

 

The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact.

TR12

18 months

5.5.c

 

The bench is inaccessible because it is only 18 inches deep.

LR1

18 months

5.6

 

Women´s Lower Level Locker Room by Pool

 

 

5.6.a

 

The door is inaccessible because it requires 9 pounds of force to open.

D2

18 months

5.6.b

 

The air dryers protrude into the walkway and are not detectable to blind persons using a cane.

AR8

18 months

5.6.c

 

The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact.

TR12

18 months

5.6.d

 

The bench is inaccessible because it is only 18 inches deep.

LR1

18 months

5.7

 

Lower Level Family Locker Room by Pool

 

 

5.7.a

 

The transfer shower is inaccessible because no transfer seat is provided.

B10

18 months

5.7.b

 

The shower is inaccessible because no shower spray unit is provided and the shower head is more than 48 inches above the finished floor.

B11

18 months

5.7.c

 

No accessible towel hook has been provided.

TR1

18 months

5.7.d

 

The bench is inaccessible because it is only 18 inches deep.

LR1

18 months

5.8

 

Pool Area

 

 

5.8.a

 

There is no access to the swimming pool for people with disabilities.

PO1

18 months

5.8.b

 

Although an accessible drinking fountain is provided, there is no drinking fountain provided for people who have difficulty bending or stooping.

DF3

18 months

5.8.c

 

The coin changer is inaccessible because it is mounted with the controls 61 inches above the finished floor.

TR5

18 months

5.8.d

 

The disposable swimpants machine is inaccessible because it is mounted with the controls 55 inches above the finished floor.

TR5

18 months

5.8.e

 

The disposable swimpants machine protrudes into the walkway and is not detectable to blind persons using a cane.

AR8

18 months

 