ATTACHMENT K: Program Access in Existing FacilitiesPlease Note: Paragraph 58 of the Agreement requires that within six months of the effective date of this Agreement, the City will provide signage as necessary to comply with 28 C.F.R. § 35.163(b), after having surveyed all facilities that are the subject of this Agreement for the purpose of identifying those that have multiple entrances not all of which are accessible. The technical requirements and, where appropriate, the scoping requirements of the Standards are used as a guide for determining whether a program or activity held in an existing facility is “readily accessible to and usable by” persons with disabilities and for determining what changes are necessary to make this program or activity accessible if it continues to be provided in the existing facility in question. See 28 C.F.R. §§ 35.150(b)(1), 35.151. The chart below lists the facilities surveyed by the Department, the access issues identified during the survey, and the actions required to correct the access issues. Required actions are listed using an alphanumeric code. The key to the alphanumeric codes is provided in Attachment M to this Agreement. In order to ensure that the programs, services, and activities housed in the City’s facilities are accessible to persons with disabilities, when viewed in their entirety, the City will take the actions referenced by the alphanumeric code and described in detail in Attachment M to this Settlement Agreement within the time period specified below, which time period begins to run on the effective date of the Agreement. |
|||
item # | Access Issue | Required Action | Completion Date |
---|---|---|---|
1. | City Hall - 25 Dorrance Street | ||
1.1. | Entrance | ||
1.1.a. | The building does not have directional signage posted at inaccessible entrances. | D16 | 12 months |
1.1.b. | The building does not have the International Symbol of Accessibility posted at accessible entrances. | D16 | 12 months |
1.2. | Lift into Building | ||
1.2.a. | The lift is inaccessible because it requires that a key be obtained from an employee before the lift can be operated. | LF1 | 12 months |
1.2.b. | The route is inaccessible because it slopes 14.4%. | AR2 | 12 months |
1.2.c. | The lift is inaccessible because to receive assistance, a person is required to summon an employee through the use of a buzzer that, when used, did not result in assistance arriving. | M2 | 12 months |
1.3. | First Floor Women’s Toilet Room (stalls) | ||
1.3.a. | The toilet room sign is inaccessible. | TR17 | 12 months |
1.3.b. | The door is inaccessible because it requires 10 pounds of force to open. | D2 | 12 months |
1.3.c. | The pull side of the door, which is accessed through a front approach, is inaccessible because it has only 8 inches of clear space on the latch side. | D6 | 12 months |
1.3.d. | The door is inaccessible because there is a 1 inch high threshold. | D23 | 12 months |
1.3.e. | The hand dryer protrudes into the walkway and is not detectable to blind persons using a cane. | AR8 | 12 months |
1.3.f. | No accessible mirror has been provided. | TR14 | 12 months |
1.3.g. | The lavatory is inaccessible because the bottom of the apron is 27 ½ inches high. | TR11 | 12 months |
1.3.h. | The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact. | TR12 | 12 months |
1.3.i. | The designated accessible toilet stall is inaccessible because it is 54 inches long. | ST16 | 12 months |
1.3.j. | The designated accessible toilet is inaccessible because its centerline is 16 inches from the side wall. | ST17 | 12 months |
1.3.k. | The toilet is inaccessible because the flush control is on the closed side. | SU1 | 12 months |
1.3.l. | The toilet paper dispenser in the designated accessible stall is inaccessible because it is not below the grab bar and is not 36 inches or less from the rear wall. | ST19 | 12 months |
1.3.m. | The designated accessible toilet is inaccessible because the side grab bar is less than 40 inches long and is mounted more than 12 inches from the rear wall. | ST7 | 12 months |
1.3.n. | The route into the toilet room vestibule is inaccessible because there is a 1 inch high threshold into the vestibule, and a ¾ inch high threshold out of the vestibule. | AR2 | 12 months |
1.4. | First Floor Men’s Toilet Room (stalls) | ||
1.4.a. | The toilet room sign is inaccessible. | TR17 | 12 months |
1.4.b. | The door is inaccessible because it requires 8 pounds of force to open. | D2 | 12 months |
1.4.c. | The pull side of the door, which is accessed through a front approach, is inaccessible because it has only 8 inches of clear space on the latch side. | D6 | 12 months |
1.4.d. | The door is inaccessible because there is a 1 inch high threshold. | D23 | 12 months |
1.4.e. | The lavatory is inaccessible because the bottom of the apron is 26 inches high. | TR11 | 12 months |
1.4.f. | The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact. | TR12 | 12 months |
1.4.g. | The designated accessible toilet stall is inaccessible because it is 54 inches long. | ST16 | 12 months |
1.4.h. | No accessible coat hook has been provided. | TR1 | 12 months |
1.4.i. | The toilet paper dispenser in the designated accessible stall is inaccessible because it is not below the grab bar and is not 36 inches or less from the rear wall. | ST19 | 12 months |
1.4.j. | The designated accessible toilet is inaccessible because the side grab bar is less than 40 inches long and is mounted more than 12 inches from the rear wall. | ST7 | 12 months |
1.4.k. | The route into the toilet room vestibule is inaccessible because there is a 1 inch high threshold into the vestibule, and a ¾ inch high threshold out of the vestibule. | AR2 | 12 months |
1.5. | First Floor Public Telephone | ||
1.5.a. | The telephone is inaccessible because it is 57 inches high to the highest operable part. | TT1 | 12 months |
1.6. | First Floor Office # 104 City Registrar, Vital Statistics | ||
1.6.a. | The signage provided is inaccessible because it does not have raised and Braille characters. | D26 | 12 months |
1.6.b. | The door is inaccessible because knob hardware is used. | D1 | 12 months |
1.6.c. | The door is inaccessible because it has an opening width of only 25 inches. | D25 | 12 months |
1.6.d. | The door is inaccessible because it requires 13 pounds of force to open. | D2 | 12 months |
1.6.e. | The counter protrudes into the walkway and is not detectable to blind persons using a cane. | AR8 | 12 months |
1.6.f. | The counter is inaccessible because it is 42 inches high. | C6 | 12 months |
1.6.g. | Instructions for services are provided via printed sign only, with no services for persons who are blind or who have low vision or who, otherwise, cannot read printed signs due to a disability. | M2 | 12 months |
1.6.h. | Forms for services are provided in written paper form with no options for accessible forms in alternate format. | M2 | 12 months |
1.7. | First Floor Office #103 Snack Bar | ||
1.7.a. | The counter is inaccessible because it is 40 inches high. | C6 | 12 months |
1.8. | First Floor Office #102 Voter Registration | ||
1.8.a. | The signage provided is inaccessible because it does not have raised and Braille characters. | D26 | 12 months |
1.8.b. | The door is inaccessible because it has an opening width of only 31 inches. | D25 | 12 months |
1.8.c. | The door is inaccessible because knob hardware is used. | D1 | 12 months |
1.8.d. | The door is inaccessible because it requires 15 pounds of force to open. | D2 | 12 months |
1.8.e. | The door is inaccessible because there is a 1 inch high threshold on both sides. | D23 | 12 months |
1.9. | First Floor Office #101 Bureau of Licenses | ||
1.9.a. | The signage provided is inaccessible because it does not have raised and Braille characters. | D26 | 12 months |
1.9.b. | The door is inaccessible because it requires 13 pounds of force to open. | D2 | 12 months |
1.9.c. | The door is inaccessible because knob hardware is used. | D1 | 12 months |
1.9.d. | The door is inaccessible because there is a 1 inch high threshold. | D23 | 12 months |
1.9.e. | The interior office door is inaccessible because it has an opening width of only 28 inches. | D25 | 12 months |
1.10. | First Floor Office #112 Hearing Room | ||
1.10.a. | The signage provided is inaccessible because it does not have raised and Braille characters. | D26 | 12 months |
1.10.b. | The door is inaccessible because it requires 10 pounds of force to open. | D2 | 12 months |
1.10.c. | The door is inaccessible because knob hardware is used. | D1 | 12 months |
1.10.d. | The door is inaccessible because there is a 1 inch high threshold. | D23 | 12 months |
1.11. | First Floor Office # 111 | ||
1.11.a. | The signage provided is inaccessible because it does not have raised and Braille characters. | D26 | 12 months |
1.11.b. | The door is inaccessible because it requires 9 pounds of force to open. | D2 | 12 months |
1.11.c. | The door is inaccessible because there is a 1 inch high threshold. | D23 | 12 months |
1.11.d. | The door is inaccessible because it has an opening width of only 27 inches. | D25 | 12 months |
1.12. | Second Floor Office #201 | ||
1.12.a. | The signage provided is inaccessible because it does not have raised and Braille characters. | D26 | 12 months |
1.12.b. | The door is inaccessible because it requires 13 pounds of force to open. | D2 | 12 months |
1.12.c. | The door is inaccessible because knob hardware is used. | D1 | 12 months |
1.12.d. | The door is inaccessible because it has an opening width of only 28 inches. | D25 | 12 months |
1.13. | Route to Mayor’s Office | ||
1.13.a. | The route to the Mayor’s office is inaccessible because there is a 1 inch change in level. | AR2 | 12 months |
1.14. | Second Floor Office #202 Mayor Main Door | ||
1.14.a. | The signage provided is inaccessible because it does not have raised and Braille characters. | D26 | 12 months |
1.14.b. | The door is inaccessible because it has an opening width of only 28 inches. | D25 | 12 months |
1.14.c. | The door is inaccessible because it requires 15 pounds of force to open. | D2 | 12 months |
1.14.d. | The door is inaccessible because knob hardware is used. | D1 | 12 months |
1.14.e. | The door is inaccessible because there is a 1 inch high threshold. | D23 | 12 months |
1.15. | Second Floor Office #203 City Collector | ||
1.15.a. | The signage provided is inaccessible because it does not have raised and Braille characters. | D26 | 12 months |
1.15.b. | The higher counter is inaccessible because it is 51 ½ inches high. | C6 | 12 months |
1.15.c. | The lower counter is inaccessible because it is 42 inches high. | C6 | 12 months |
1.15.d. | The information counter is inaccessible because it is 43 inches high. | C6 | 12 months |
1.16. | Second Floor Office # 205 | ||
1.16.a. | The signage provided is inaccessible because it does not have raised and Braille characters. | D26 | 12 months |
1.16.b. | The door is inaccessible because knob hardware is used. | D1 | 12 months |
1.16.c. | The door is inaccessible because there is a 1 inch high threshold. | D23 | 12 months |
1.17. | Second Floor Office #207 Intergovernmental Relations, Administration, Policy | ||
1.17.a. | The signage provided is inaccessible because it does not have raised and Braille characters. | D26 | 12 months |
1.17.b. | The door is inaccessible because knob hardware is used. | D1 | 12 months |
1.17.c. | The door is inaccessible because it requires 14 pounds of force to open. | D2 | 12 months |
1.18. | Second Floor Office #208 Tax Assessor | ||
1.18.a. | The signage provided is inaccessible because it does not have raised and Braille characters. | D26 | 12 months |
1.18.b. | The computer and printer are inaccessible because they are on a counter that is 42 inches high. | C3 | 12 months |
1.18.c. | The counter is inaccessible because it is 42 inches high. | C6 | 12 months |
1.19. | 3rd Floor Office # 301 | ||
1.19.a. | The signage provided is inaccessible because it is mounted on the door and does not have raised and Braille characters. | D26 | 12 months |
1.19.b. | The door is inaccessible because knob hardware is used. | D1 | 12 months |
1.19.c. | The door is inaccessible because the threshold is greater than ¾ inch. | D23 | 12 months |
1.20. | 3rd Floor Office # 302 Board of Aldermen Chamber | ||
1.20.a. | The signage provided is inaccessible because it is mounted on the door and does not have raised and Braille characters. | D26 | 12 months |
1.20.b. | The door is inaccessible because knob hardware is used. | D1 | 12 months |
1.20.c. | The door is inaccessible because the threshold is greater than ¾ inch. | D23 | 12 months |
1.20.d. | The door is inaccessible because it has an opening width of only 24 inches. | D25 | 12 months |
1.21. | 3rd Floor Office # 303 City Council Chamber | ||
1.21.a. | The signage provided is inaccessible because it is mounted on the door and does not have raised and Braille characters. | D26 | 12 months |
1.21.b. | The door is inaccessible because knob hardware is used. | D1 | 12 months |
1.21.c. | The door is inaccessible because the threshold is greater than ¾ inch. | D23 | 12 months |
1.22. | 3rd Floor Conference Room A | ||
1.22.a. | The door is inaccessible because a thumb latch is used. | D1 | 12 months |
1.22.b. | The door is inaccessible because the threshold is greater than ¾ inch. | D23 | 12 months |
1.23. | 3rd Floor Office # 305 Purchasing Department | ||
1.23.a. | The signage provided is inaccessible because it is mounted on the door and does not have raised and Braille characters. | D26 | 12 months |
1.23.b. | The door is inaccessible because knob hardware is used. | D1 | 12 months |
1.23.c. | The door is inaccessible because the threshold is greater than ¾ inch. | D23 | 12 months |
1.24. | 3rd Floor Employee Women’s Toilet Room (stalls) | ||
1.24.a. | There is no signage directing people with disabilities to the accessible toilet rooms. | TR16 | 12 months |
1.25. | 3rd Floor Employee Men’s Toilet Room (stalls) | ||
1.25.a. | There is no signage directing people with disabilities to the accessible toilet rooms. | TR16 | 12 months |
1.26. | 3rd Floor Office # 306 | ||
1.26.a. | The signage provided is inaccessible because it is mounted on the door and does not have raised and Braille characters. | D26 | 12 months |
1.26.b. | The door is inaccessible because knob hardware is used. | D1 | 12 months |
1.26.c. | The door is inaccessible because the threshold is greater than ¾ inch. | D23 | 12 months |
1.27. | 3rd Floor Office # 307 Internal Auditor/Council President (main door) | ||
1.27.a. | The signage provided is inaccessible because it is mounted on the door and does not have raised and Braille characters. | D26 | 12 months |
1.27.b. | The door is inaccessible because knob hardware is used. | D1 | 12 months |
1.27.c. | The door is inaccessible because it requires 12 pounds of force to open. | D2 | 12 months |
1.27.d. | The door is inaccessible because the threshold is greater than ¾ inch. | D23 | 12 months |
1.28. | 3rd Floor Office # 308 | ||
1.28.a. | The signage provided is inaccessible because it is mounted on the door and does not have raised and Braille characters. | D26 | 12 months |
1.28.b. | The door is inaccessible because knob hardware is used. | D1 | 12 months |
1.28.c. | The door is inaccessible because the threshold is greater than ¾ inch. | D23 | 12 months |
1.29. | 3rd Floor Office # 310 City Council | ||
1.29.a. | The signage provided is inaccessible because it is mounted on the door and does not have raised and Braille characters. | D26 | 12 months |
1.29.b. | The door is inaccessible because knob hardware is used. | D1 | 12 months |
1.29.c. | The door is inaccessible because the threshold is greater than ¾ inch. | D23 | 12 months |
1.29.d. | The room is inaccessible to people with hearing disabilities because there is no assistive listening system provided. | AA4 | 12 months |
1.30. | 3rd Floor Office # 311 City Clerk | ||
1.30.a. | The signage provided is inaccessible because it is mounted on the door and does not have raised and Braille characters. | D26 | 12 months |
1.30.b. | The door is inaccessible because knob hardware is used. | D1 | 12 months |
1.30.c. | The door is inaccessible because the threshold is greater than ¾ inch. | D23 | 12 months |
1.30.d. | The counter is inaccessible because it is 42 inches high. | C6 | 12 months |
1.30.e. | The push side of the door, which is accessed through a front approach and which has both a closer and a latch, is inaccessible because it does not have enough clear space on the latch side. | D7 | 12 months |
1.30.f. | The pull side of the door, which is accessed through a front approach, is inaccessible because it does not have enough clear space on the latch side. | D6 | 12 months |
1.31. | 4th Floor Office # 401 Personnel (main door) | ||
1.31.a. | The door is inaccessible because it requires 19 pounds of force to open. | D2 | 12 months |
1.31.b. | The signage provided is inaccessible because it is mounted on the door and does not have raised and Braille characters. | D26 | 12 months |
1.32. | 4th Floor Office # 401 EEO Office (inner door) | ||
1.32.a. | The door is inaccessible because knob hardware is used. | D1 | 12 months |
1.33. | 4th Floor Office # 402 | ||
1.33.a. | The door is inaccessible because knob hardware is used. | D1 | 12 months |
1.33.b. | The signage provided is inaccessible because it is mounted on the door and does not have raised and Braille characters. | D26 | 12 months |
1.33.c. | The door is inaccessible because the threshold is greater than ¾ inch. | D23 | 12 months |
1.33.d. | The push side of the door, which is accessed through a front approach and which has both a closer and a latch, is inaccessible because it has inadequate clear space on the latch side. | D7 | 12 months |
1.33.e. | The pull side of the door, which is accessed through a front approach, is inaccessible because it has inadequate clear space on the latch side. | D6 | 12 months |
1.34. | 4th Floor Office # 403 | ||
1.34.a. | The door is inaccessible because knob hardware is used. | D1 | 12 months |
1.34.b. | The signage provided is inaccessible because it is mounted on the door and does not have raised and Braille characters. | D26 | 12 months |
1.34.c. | The door is inaccessible because the threshold is greater than ¾ inch. | D23 | 12 months |
1.34.d. | The push side of the door, which is accessed through a front approach and which has both a closer and a latch, is inaccessible because it has inadequate clear space on the latch side. | D7 | 12 months |
1.34.e. | The pull side of the door, which is accessed through a front approach, is inaccessible because it has inadequate clear space on the latch side. | D6 | 12 months |
1.35. | 4th Floor Office # 404 City Council Chamber Gallery | ||
1.35.a. | The signage provided is inaccessible because it is mounted on the door and does not have raised and Braille characters. | D26 | 12 months |
1.35.b. | The door is inaccessible because knob hardware is used. | D1 | 12 months |
1.35.c. | The door is inaccessible because the threshold is greater than ¾ inch. | D23 | 12 months |
1.36. | 4th Floor Office # 405 City Treasurer | ||
1.36.a. | The signage provided is inaccessible because it is mounted on the door and does not have raised and Braille characters. | D26 | 12 months |
1.36.b. | The door is inaccessible because knob hardware is used. | D1 | 12 months |
1.36.c. | The door is inaccessible because the threshold is greater than ¾ inch. | D23 | 12 months |
1.36.d. | The push side of the door, which is accessed through a front approach and which has both a closer and a latch, is inaccessible because it has inadequate clear space on the latch side. | D7 | 12 months |
1.36.e. | The pull side of the door, which is accessed through a front approach, is inaccessible because it has inadequate clear space on the latch side. | D6 | 12 months |
1.37. | 4th Floor Employee Women’s Toilet Room (stalls) | ||
1.37.a. | There is no signage directing people with disabilities to the accessible toilet rooms. | TR16 | 12 months |
1.38. | 4th Floor Employee Men’s Toilet Room (stalls) | ||
1.38.a. | There is no signage directing people with disabilities to the accessible toilet rooms. | TR16 | 12 months |
1.39. | 4th Floor Office # 407 Public Property | ||
1.39.a. | The signage provided is inaccessible because it is mounted on the door and does not have raised and Braille characters. | D26 | 12 months |
1.39.b. | The door is inaccessible because knob hardware is used. | D1 | 12 months |
1.39.c. | The door is inaccessible because the threshold is greater than ¾ inch. | D23 | 12 months |
1.39.d. | The push side of the door, which is accessed through a front approach and which has both a closer and a latch, is inaccessible because it does not have enough clear space on the latch side. | D7 | 12 months |
1.39.e. | The counter is inaccessible because it is 42 inches high. | C6 | 12 months |
1.40. | 4th Floor Office # 408 Data Processing | ||
1.40.a. | The signage provided is inaccessible because it is mounted on the door and does not have raised and Braille characters. | D26 | 12 months |
1.40.b. | The door is inaccessible because knob hardware is used. | D1 | 12 months |
1.40.c. | The door is inaccessible because the threshold is greater than ¾ inch. | D23 | 12 months |
1.40.d. | The counter is inaccessible because it is 42 inches high. | C6 | 12 months |
1.41. | 4th Floor Office # 409 Retirement Federal Office | ||
1.41.a. | The door is inaccessible because it has an opening width of only 26 inches. | D25 | 12 months |
1.41.b. | The door is inaccessible because knob hardware is used. | D1 | 12 months |
1.41.c. | The door is inaccessible because the threshold is greater than ¾ inch. | D23 | 12 months |
1.42. | 4th Floor Office # 410 Controller | ||
1.42.a. | The door is inaccessible because knob hardware is used. | D1 | 12 months |
1.42.b. | The door is inaccessible because the threshold is greater than ¾ inch. | D23 | 12 months |
1.42.c. | The counter is inaccessible because it is 42 inches high. | C6 | 12 months |
1.43. | 4th Floor Office # 411 Payroll Office | ||
1.43.a. | The signage provided is inaccessible because it does not have raised and Braille characters. | D26 | 12 months |
1.43.b. | The door is inaccessible because knob hardware is used. | D1 | 12 months |
1.43.c. | The door is inaccessible because the threshold is greater than ¾ inch. | D23 | 12 months |
1.43.d. | The counter is inaccessible because it is 42 inches high. | C6 | 12 months |
1.44. | 5th Floor Office # 501 Office of Probate Court | ||
1.44.a. | The signage provided is inaccessible because it does not have raised and Braille characters. | D26 | 12 months |
1.44.b. | The door is inaccessible because the threshold is greater than ¾ inch. | D23 | 12 months |
1.44.c. | The counter is inaccessible because it is 42 inches high. | C6 | 12 months |
1.45. | 5th Floor Route to City Archives | ||
1.45.a. | There is no access to the City Archives for people with mobility impairments. | AR9 | 12 months |
1.45.b. | The route is inaccessible because there is a 1 inch gap on the floor. | AR2 | 12 months |
1.46. | 5th Floor Office # 502 City Archives | ||
1.46.a. | The signage provided is inaccessible because it does not have raised and Braille characters. | D26 | 12 months |
1.46.b. | The door is inaccessible because knob hardware is used. | D1 | 12 months |
1.46.c. | The door is inaccessible because the threshold is greater than ¾ inch. | D23 | 12 months |
1.47. | 5th Floor Office # 503 | ||
1.47.a. | The signage provided is inaccessible because it is mounted on the door and does not have raised and Braille characters. | D26 | 12 months |
1.47.b. | The door is inaccessible because knob hardware is used. | D1 | 12 months |
1.47.c. | The door is inaccessible because the threshold is greater than ¾ inch. | D23 | 12 months |
1.47.d. | The door is inaccessible because it has an opening width of only 27 inches. | D25 | 12 months |
1.48. | 5th Floor Office # 504 room locked during site visit | ||
1.48.a. | The signage provided is inaccessible because it is mounted on the door and does not have raised and Braille characters. | D26 | 12 months |
1.48.b. | The door is inaccessible because knob hardware is used. | D1 | 12 months |
1.48.c. | The door is inaccessible because the threshold is greater than ¾ inch. | D23 | 12 months |
1.48.d. | The room was unable to be surveyed during the site visit. Complete necessary remedial actions, consistent with the rest of this agreement, to make this room accessible to people with a disability. | AR3, AR8, C8, D2, D8 | 12 months |
1.49. | 5th Floor Office #506 Recorder of Deeds - Land Records | ||
1.49.a. | The signage provided is inaccessible because it does not have raised and Braille characters. | D26 | 12 months |
1.49.b. | The door is inaccessible because the threshold is greater than ¾ inch. | D23 | 12 months |
1.49.c. | The counter is inaccessible because it is 42 inches high. | C6 | 12 months |
1.50. | 5th Floor Office # 507 (private) room locked during site visit | ||
1.50.a. | The signage provided is inaccessible because it is mounted on the door and does not have raised and Braille characters. | D26 | 12 months |
1.50.b. | The door is inaccessible because knob hardware is used. | D1 | 12 months |
1.50.c. | The door is inaccessible because the threshold is greater than ¾ inch. | D23 | 12 months |
1.50.d. | The push side of the door, which is accessed through a front approach and which has both a closer and a latch, is inaccessible because it has inadequate clear space on the latch side. | D7 | 12 months |
1.50.e. | The room was unable to be surveyed during the site visit. Complete necessary remedial actions, consistent with the rest of this agreement, to make this room accessible to people with a disability. | AR3, AR8, C8, D2, D8 | 12 months |
1.51. | 5th Floor Office # 508 Recorder of Deeds - Copy Room | ||
1.51.a. | The signage provided is inaccessible because it is mounted on the door and does not have raised and Braille characters. | D26 | 12 months |
1.51.b. | The door is inaccessible because knob hardware is used. | D1 | 12 months |
1.51.c. | The door is inaccessible because the threshold is greater than ¾ inch. | D23 | 12 months |
1.52. | 5th Floor Office # 509 | ||
1.52.a. | The signage provided is inaccessible because it is mounted on the door and does not have raised and Braille characters. | D26 | 12 months |
1.52.b. | The door is inaccessible because knob hardware is used. | D1 | 12 months |
1.52.c. | The door is inaccessible because the threshold is greater than ¾ inch. | D23 | 12 months |
1.53. | 5th Floor Office # 510 (private) room locked during site visit | ||
1.53.a. | The signage provided is inaccessible because it is mounted on the door and does not have raised and Braille characters. | D26 | 12 months |
1.53.b. | The door is inaccessible because knob hardware is used. | D1 | 12 months |
1.53.c. | The door is inaccessible because the threshold is greater than ¾ inch. | D23 | 12 months |
1.53.d. | The room was unable to be surveyed during the site visit. Complete necessary remedial actions, consistent with the rest of this agreement, to make this room accessible to people with a disability. | AR3, AR8, C8, D2, D8 | 12 months |
1.54. | 5th Floor Office # 511 Probate Court | ||
1.54.a. | The signage provided is inaccessible because it is mounted on the door and does not have raised and Braille characters. | D26 | 12 months |
1.54.b. | The door is inaccessible because knob hardware is used. | D1 | 12 months |
1.54.c. | The door is inaccessible because the threshold is greater than ¾ inch. | D23 | 12 months |
1.54.d. | The double-leaf door is inaccessible because each leaf has less than 32 inches of clear opening width. | D5 | 12 months |
1.54.e. | The room is inaccessible to people with hearing disabilities because there is no assistive listening system provided. | AA4 | 12 months |
1.55. | 5th Floor Employee Women’s Toilet Room (stalls) | ||
1.55.a. | There is no signage directing people with disabilities to the accessible toilet rooms. | TR16 | 12 months |
1.56. | 5th Floor employee Men’s Toilet Room (stalls) | ||
1.56.a. | There is no signage directing people with disabilities to the accessible toilet rooms. | TR16 | 12 months |
2. | Washington Park Community Center - 42 Jillson Street | ||
2.1. | Parking | ||
2.1.a. | The parking lot, with a total of 16 parking spaces, is inaccessible because there are no designated accessible parking areas. This lot requires 1 van accessible space. | P3 | 24 months |
2.2. | Ramp from parking to Main Entrance | ||
2.2.a. | The ramp is inaccessible because there is no handrails on one side of the ramp. | R4 | 24 months |
2.2.b. | The ramp is inaccessible because the top of the handrail is more than 38 inches above the ground and it is greater than 1 ½ inches in diameter. | R4 | 24 months |
2.2.c. | The ramp is inaccessible because it does not have edge protection at the drop off sides. | R1 | 24 months |
2.2.d. | The ramp is inaccessible because there are no extensions at the bottom landing. | R4 | 24 months |
2.2.e. | The ramp is inaccessible because the ends of the handrails are not rounded or returned. | R4 | 24 months |
2.3. | Main Entrance | ||
2.3.a. | The door is inaccessible because it has an opening width of only 29 inches. | D25 | 24 months |
2.4. | Women’s Toilet Room (stalls) | ||
2.4.a. | The toilet room sign is inaccessible because it is not mounted on the latch side of the door. | TR17 | 24 months |
2.4.b. | The door is inaccessible because knob hardware is used. | D1 | 24 months |
2.4.c. | The door is inaccessible because it has an opening width of only 30 inches. | D25 | 24 months |
2.4.d. | The lavatory is inaccessible because it has twist-type hardware. | TR10 | 24 months |
2.4.e. | The designated accessible toilet is inaccessible because the flush control is on the closed side. | ST2 | 24 months |
2.4.f. | The designated accessible toilet is inaccessible because the side grab bar is not at least 40 inches long and it is mounted so that the far end is less than 52 inches from the rear wall. | ST7 | 24 months |
2.4.g. | The designated accessible toilet is inaccessible because the grab bar is mounted 3 inches from the wall. | ST13 | 24 months |
2.4.h. | There is no rear grab bar provided at the designated accessible toilet. | ST3 | 24 months |
2.5. | Men’s Toilet Room (stalls) | ||
2.5.a. | The toilet room sign is inaccessible because it is not mounted on the latch side of the door. | TR17 | 24 months |
2.5.b. | The door is inaccessible because knob hardware is used. | D1 | 24 months |
2.5.c. | The door is inaccessible because it has an opening width of only 29 ½ inches. | D25 | 24 months |
2.5.d. | The lavatory is inaccessible because it has twist-type hardware. | TR10 | 24 months |
2.5.e. | The designated accessible toilet is inaccessible because the side grab bar is not at least 40 inches long and it is mounted so that the far end is less than 52 inches from the rear wall. | ST7 | 24 months |
2.5.f. | The designated accessible toilet is inaccessible because the grab bar is mounted 3 inches from the wall. | ST13 | 24 months |
2.5.g. | There is no rear grab bar provided at the designated accessible toilet. | ST3 | 24 months |
2.6. | Drinking Fountain near Toilet Rooms | ||
2.6.a. | The drinking fountain is inaccessible because the controls are not front-mounted or side-mounted near the front edge of the unit and require greater than 5 pounds of force and twisting to operate. | DF2 | 24 months |
2.6.b. | The drinking fountain is inaccessible because it provides only 24 inches of clear knee height. | DF5 | 24 months |
2.6.c. | There is no drinking fountain provided for people who have difficulty bending or stooping. | DF3 | 24 months |
2.7. | Office and other Doors Throughout Facility | ||
2.7.a. | The doors are inaccessible because several have an opening width of only 29 inches. | D25 | 24 months |
2.7.b. | The doors are inaccessible because knob hardware is used. | D1 | 24 months |
2.7.c. | The signage provided is inaccessible because it is often mounted on the door and does not have raised and Braille characters. | D26 | 24 months |
2.8. | Multi Purpose Room | ||
2.8.a. | The counter is inaccessible because it is 40 inches high. | C6 | 24 months |
2.9. | Multi Purpose Room Women’s Toilet (stalls) | ||
2.9.a. | The designated accessible toilet is inaccessible because its centerline is 18 ½ inches from the side wall. | ST17 | 24 months |
2.9.b. | No accessible coat hook has been provided. | TR1 | 24 months |
2.10. | Multi Purpose Room Men’s Toilet (stalls) | ||
2.10.a. | The designated accessible toilet is inaccessible because its centerline is 18 ½ inches from the side wall. | ST17 | 24 months |
2.10.b. | No accessible coat hook has been provided. | TR1 | 24 months |
2.11. | Multi Purpose Room Drinking Fountain | ||
2.11.a. | The drinking fountain protrudes into the walkway and is not detectable to blind persons using a cane. | AR8 | 24 months |
2.11.b. | There is no signage directing people with disabilities to the accessible drinking fountains. | M2 | 24 months |
2.12. | Playground Area | ||
2.12.a. | None of the play equipment is usable by children with disabilities. | PG1 | 24 months |
3. | Museum of Natural History - 1100 Elmwood Avenue | ||
3.1. | Front Parking Area | ||
3.1.a. | The parking lot is inaccessible because it only has 1 space designated as accessible, and it is less than 96 inches wide. This lot requires at least 1 van accessible space. | P3 | 12 months |
3.1.b. | The designated accessible parking is inaccessible because it lacks vertical signage. | P6 | 12 months |
3.2. | North Parking Area | ||
3.2.a. | The parking lot is inaccessible because it only has 1 space designated as accessible, and the access aisle serving that space is less than 96 inches wide. This lot requires at least 1 van accessible space. | P3 | 12 months |
3.2.b. | The designated accessible parking is inaccessible because it lacks van accessible signage. | P6 | 12 months |
3.3. | Entrance | ||
3.3.a. | The building does not have directional signage posted at inaccessible entrances and does not have the International Symbol of Accessibility posted appropriately at accessible entrances. | D16 | 12 months |
3.4. | Lift | ||
3.4.a. | The lift is inaccessible because it requires that a key be obtained from an employee before the lift can be operated. | LF1 | 12 months |
3.4.b. | The lift is inaccessible because the controls require tight grasping and twisting of the wrist to operate. | LF2 | 12 months |
3.5. | Planetarium | ||
3.5.a. | The planetarium is inaccessible to people with hearing disabilities because, although there is fixed seating and an audio amplification system, there is no assistive listening system provided. | AA4 | 12 months |
3.5.b. | The planetarium, containing 73 seats, is inaccessible because only 2 wheelchair seating areas are provided. A total of 4 wheelchair seating areas are required. | AA6 | 12 months |
3.6. | Men’s Toilet Room (stalls) | ||
3.6.a. | The toilet room sign is inaccessible because it is not mounted on the latch side of the door. | TR17 | 12 months |
3.6.b. | Although an audible alarm is provided in this facility, there is no visual alarm appliance in the toilet room. | TR21 | 12 months |
3.6.c. | The paper towel dispenser is inaccessible because it is mounted with the controls 56 inches high. | TR5 | 12 months |
3.6.d. | The lavatory is inaccessible because the bottom of the apron is 28 inches high. | TR11 | 12 months |
3.6.e. | No accessible coat hook has been provided. | TR1 | 12 months |
3.6.f. | The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact. | TR12 | 12 months |
3.6.g. | The designated accessible toilet is inaccessible because there is insufficient clear floor space. | ST18 | 12 months |
3.6.h. | The designated accessible toilet is inaccessible because its centerline is 22 inches from the side wall. | ST17 | 12 months |
3.6.i. | The designated accessible toilet is inaccessible because the flush control is on the closed side. | ST2 | 12 months |
3.6.j. | The designated accessible toilet is inaccessible because the side grab bar is not at least 40 inches long and it is mounted so that the far end is 49 inches from the rear wall. | ST7 | 12 months |
3.6.k. | The designated accessible toilet is inaccessible because the rear grab bar is not 30 inches long and it is mounted 7 ½ inches from the side wall. | ST4 | 12 months |
3.6.l. | The urinal is inaccessible because it has not been maintained in working order. | M1 | 12 months |
3.7. | Women’s Toilet Room (stalls) | ||
3.7.a. | The toilet room sign is inaccessible because it is not mounted on the latch side of the door. | TR17 | 12 months |
3.7.b. | Although an audible alarm is provided in this facility, there is no visual alarm appliance in the toilet room. | TR21 | 12 months |
3.7.c. | The paper towel dispenser is inaccessible because it is mounted with the controls 56 inches high. | TR5 | 12 months |
3.7.d. | The lavatory is inaccessible because the bottom of the apron is 28 inches high. | TR11 | 12 months |
3.7.e. | The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact. | TR12 | 12 months |
3.7.f. | The designated accessible toilet is inaccessible because there is insufficient clear floor space. | ST18 | 12 months |
3.7.g. | The designated accessible toilet is inaccessible because its centerline is 22 inches from the side wall. | ST17 | 12 months |
3.7.h. | The designated accessible toilet is inaccessible because the side grab bar is not at least 40 inches long and it is mounted so that the far end is 49 inches from the rear wall. | ST7 | 12 months |
3.7.i. | The designated accessible toilet is inaccessible because the rear grab bar is not 30 inches long and it is mounted 7 ½ inches from the side wall. | ST4 | 12 months |
4. | Public Works - 700 Allens Avenue | ||
4.1. | Exterior Entrance | ||
4.1.a. | There are no accessible entrances. | D12 | 6 months |
4.1.b. | The main entrance is inaccessible because it has a 7 inch step up to the landing. | D13 | 6 months |
4.2. | Plans Office | ||
4.2.a. | The counter is inaccessible because it is 38 ½ inches high. | C6 | 6 months |
4.3. | Receptionist Office | ||
4.3.a. | The door is inaccessible because knob hardware is used. | D1 | 6 months |
4.3.b. | The counter is inaccessible because it is 42 inches high. | C6 | 6 months |
5. | Dalrymple Paddle Boat Area - 1000 Elmwood Avenue | ||
5.1. | Main Building Entrance | ||
5.1.a. | The door is inaccessible because it has an opening width of only 26 inches. | D25 | 12 months |
5.2. | Route to Main Building Entrance | ||
5.2.a. | The route is inaccessible because there is a 5.4% slope with no ramp features. | AR1 | 12 months |
5.3. | Ramp to Ticketing | ||
5.3.a. | The ramp is inaccessible because it slopes up to 10.6%. | R3 | 12 months |
5.3.b. | The ramp is inaccessible because the ends of the handrails do not extend 12 inches and are not rounded or returned. | R4 | 12 months |
6. | Billy Taylor Park - Camp and Cypress Street | ||
6.1. | Route to Swing Area | ||
6.1.a. | The route from the north entrance is inaccessible because it slopes up to 11% and there is a step into the area. | AR1 | 12 months |
7. | Bank of America Skating Center - 2 Kennedy Plaza | ||
7.1. | Ticket Sales | ||
7.1.a. | The counter at the ticket window is inaccessible because it is 40 inches high. | C5 | 6 months |
8. | India Point Park - 109 India Street | ||
8.1. | Parking Lot | ||
8.1.a. | The designated accessible parking is inaccessible because it lacks van-accessible signage. | P6 | 12 months |
8.2. | Route from Street Parking to Waterfront | ||
8.2.a. | The route is inaccessible because it slopes up to 12%. | AR1 | 12 months |
8.3. | Route from Waterfront Area to Tree-Lined Sitting Area | ||
8.3.a. | The route is inaccessible because the transition area to the tree-lined sitting area is not smooth, stable or slip resistant. | AR1 | 12 months |
8.4. | Floating Ramp on the Right | ||
8.4.a. | The ramp is inaccessible because it slopes up to 12.7%. | R5 | 12 months |
8.4.b. | The ramp is inaccessible because the handrails are 31 inches high and there are no extensions at the top or bottom landings. | R4 | 12 months |
8.4.c. | The ramp is inaccessible because it does not have continuous edge protection at the drop-off sides. | R1 | 12 months |
8.5. | Picnic Table Area | ||
8.5.a. | The picnic tables are inaccessible because none provide the required knee space depth. | PD6 | 12 months |
8.6. | Playground Area | ||
8.6.a. | The route to the playground equipment is inaccessible because there are changes in level and it is not firm, stable, or slip resistant. | AR1 | 12 months |
8.6.b. | None of the play equipment is usable by children with disabilities. | PG1 | 12 months |
8.7. | Drinking Fountains | ||
8.7.a. | The route to the drinking fountains is inaccessible because it is not firm, stable, or slip resistant. | AR1 | 12 months |
9. | Providence School Department - 797 Westminster Street | ||
9.1. | Parking | ||
9.1.a. | The parking lot, with a total of 56 parking spaces, is inaccessible because it requires 2 spaces designated as standard accessible spaces and 1 space designated as van accessible. | P3 | 12 months |
9.2. | Ramp | ||
9.2.a. | The ramp is inaccessible because the ends of the handrails do not extend 12 inches beyond the top and bottom of the ramp parallel with the ground surface. | R4 | 12 months |
9.3. | 1st Floor Interior Circulation | ||
9.3.a. | The fire extinguisher protrudes into the walkway and is not detectable to blind persons using a cane. | AR8 | 12 months |
9.4. | Human Resources | ||
9.4.a. | The counter is inaccessible because it is 42 inches high. | C6 | 12 months |
9.5. | Route outside of Meeting Rooms | ||
9.5.a. | The fire extinguisher protrudes into the walkway and is not detectable to blind persons using a cane. | AR8 | 12 months |
9.6. | Meeting Rooms | ||
9.6.a. | The rooms are inaccessible to people with hearing disabilities because there is no assistive listening system provided. | AA4 | 12 months |
9.7. | 2nd Floor Drinking Fountain - East Corridor | ||
9.7.a. | The wall-mounted drinking fountain is inaccessible because it provides only 21 ½ inches of clear knee height. | DF5 | 12 months |
9.7.b. | There is no drinking fountain provided for people who have difficulty bending or stooping. | DF3 | 12 months |
9.8. | 2nd Floor Men’s Toilet Rooms - South Side of East Corridor (stalls) | ||
9.8.a. | The toilet room sign is mounted on the door and has no raised or Braille characters. | TR17 | 12 months |
9.8.b. | The door is inaccessible because it requires 12 pounds of force to open. | D2 | 12 months |
9.8.c. | The paper towel dispenser protrudes into the walkway and is not detectable to blind persons using a cane. | AR8 | 12 months |
9.8.d. | The urinal is inaccessible because the rim is 24 inches high, and the flush valve is 52 inches high. | TR20 | 12 months |
9.8.e. | The toilet is inaccessible because the flush control is on the closed side. | SU1 | 12 months |
9.8.f. | No accessible coat hook has been provided. | TR1 | 12 months |
9.9. | 2nd Floor Women’s Toilet Rooms - South Side of East Corridor (stalls) | ||
9.9.a. | The door is inaccessible because it requires 8 pounds of force to open. | D2 | 12 months |
9.9.b. | The paper towel dispenser protrudes into the walkway and is not detectable to blind persons using a cane. | AR8 | 12 months |
9.9.c. | The sanitary napkin dispenser is inaccessible because the controls require twisting of the wrist to operate. | TR3 | 12 months |
9.9.d. | The toilet is inaccessible because the flush control is on the closed side. | SU1 | 12 months |
9.9.e. | The toilet is inaccessible because the side grab bar is obstructed by the toilet seat cover dispenser and toilet paper dispenser. | SU8 | 12 months |
9.10. | 2nd Floor Superintendent’s Office | ||
9.10.a. | The counter is inaccessible because it is too high. | C6 | 12 months |
10. | Vincent Brown Recreation Center - 438 Hope Street | ||
10.1. | Parking | ||
10.1.a. | The designated accessible parking is inaccessible because it is not located on the shortest accessible route to the accessible facility entrance. | P5 | 12 months |
10.1.b. | The designated standard accessible parking space is inaccessible because it slopes 7.6%. | P7 | 12 months |
10.1.c. | The designated accessible parking is inaccessible because the standard accessible space is only 90 inches wide. | P8 | 12 months |
10.1.d. | The designated accessible parking is inaccessible because the access aisle serving the van accessible space is only 90 inches wide. | P8 | 12 months |
10.1.e. | The designated van accessible parking is inaccessible because it has a running slope of 4.9%, cross slope of 2.8%, and its access aisle has a running slope of 4.2%. | P7 | 12 months |
10.2. | Route from Parking to Front Door | ||
10.2.a. | The route is inaccessible because it slopes 13%. | AR1 | 12 months |
10.3. | Ramp | ||
10.3.a. | The ramp is inaccessible because the handrails are mounted with 2 inches between the handrail and the wall. | R4 | 12 months |
10.3.b. | The ramp is inaccessible because the ends of the handrails do not extend 12 inches beyond the top and bottom of the ramp parallel with the ground surface. | R4 | 12 months |
10.4. | Interior Route by Toilet Rooms | ||
10.4.a. | The coat rack protrudes into the walkway and is not detectable to blind persons using a cane. | AR8 | 12 months |
10.4.b. | No accessible coat hook has been provided. | TR1 | 12 months |
10.4.c. | The drinking fountain protrudes into the walkway and is not detectable to blind persons using a cane. | AR8 | 12 months |
10.5. | Men’s Toilet Room (stalls) | ||
10.5.a. | The toilet room sign is mounted on the door and does not have a 60 inch centerline. | TR17 | 12 months |
10.5.b. | The door is inaccessible because it requires 9 pounds of force to open. | D2 | 12 months |
10.5.c. | The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact. | TR12 | 12 months |
10.5.d. | The toilet paper dispenser in the designated accessible stall is inaccessible because it is mounted 47 inches from the rear wall. | ST19 | 12 months |
10.5.e. | No accessible coat hook has been provided. | TR1 | 12 months |
10.5.f. | The designated accessible toilet is inaccessible because the far end of the side grab bar is 48 inches from the rear wall. | ST7 | 12 months |
10.5.g. | No accessible bench has been provided. | LR1 | 12 months |
10.5.h. | No accessible shower has been provided. | B8 | 12 months |
10.6. | Women’s Toilet Room (stalls) | ||
10.6.a. | The toilet room sign is mounted on the door and has no raised or Braille characters. | TR17 | 12 months |
10.6.b. | The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact. | TR12 | 12 months |
10.6.c. | The sanitary napkin dispenser is inaccessible because the controls require twisting of the wrist to operate. | TR3 | 12 months |
10.6.d. | The sanitary napkin dispenser protrudes into the walkway and is not detectable to blind persons using a cane. | AR8 | 12 months |
10.6.e. | The toilet paper dispenser in the designated accessible stall is inaccessible because it is mounted 49 inches from the rear wall. | ST19 | 12 months |
10.6.f. | The toilet is inaccessible because the side grab bar is 36 inches long and it is mounted with its far end less than 48 inches from the rear wall. | ST4 | 12 months |
10.6.g. | The toilet is inaccessible because the flush control is on the closed side. | ST2 | 12 months |
10.6.h. | No accessible bench has been provided. | LR1 | 12 months |
10.6.i. | No accessible shower has been provided. | B8 | 12 months |
10.7. | Drinking Fountain | ||
10.7.a. | The drinking fountain is inaccessible because it has a spout that is 43 inches high. | DF6 | 12 months |
10.7.b. | The drinking fountain protrudes into the walkway and is not detectable to blind persons using a cane. | AR8 | 12 months |
11. | Columbia Park - 65 Michigan Avenue | ||
11.1. | Route to play area | ||
11.1.a. | The route to the play area is inaccessible because there is a 6 inch step into the play area and no accessible route to any equipment. | AR1 | 6 months |
11.1.b. | None of the play equipment is usable by children with disabilities. | PG1 | 6 months |
11.2. | Picnic Tables | ||
11.2.a. | The route to the picnic tables is inaccessible because it is not firm, stable, and slip resistant. | AR1 | 6 months |
11.2.b. | The picnic tables are inaccessible because none provide the required knee space. | PD6 | 6 months |
11.3. | Basketball Court | ||
11.3.a. | The route is inaccessible because it is not firm, stable or slip resistant. | AR1 | 6 months |
12. | Fox Point Neighborhood Center - 90 Ives Street | ||
12.1. | Route Near Elevator | ||
12.1.a. | The mailbox protrudes into the walkway and is not detectable to blind persons using a cane. | AR8 | 6 months |
12.2. | Drinking Fountain on Main Level | ||
12.2.a. | The drinking fountain is inaccessible because it has a spout that is 38 inches high. | DF6 | 6 months |
12.2.b. | The drinking fountain is inaccessible because the flow of water is 2 inches high. | DF7 | 6 months |
12.2.c. | The drinking fountain is inaccessible because the water flow is 5 ¾ inches from the front of the fountain. | DF1 | 6 months |
12.2.d. | The drinking fountain is inaccessible because the controls require 11 pounds of force to operate. | DF2 | 6 months |
12.2.e. | The drinking fountain is inaccessible because it provides only 20 ½ inches of clear knee height. | DF5 | 6 months |
12.2.f. | There is no drinking fountain provided for people who have difficulty bending or stooping. | DF3 | 6 months |
12.3. | Unisex Toilet Room on Main Level (SUTR) | ||
12.3.a. | The toilet room sign is mounted on the door. | TR17 | 6 months |
12.3.b. | The door is inaccessible because it requires 7 pounds of force to open. | D2 | 6 months |
12.3.c. | The door locking mechanism is inaccessible because the controls require twisting of the wrist to operate. | TR3 | 6 months |
12.3.d. | The push side of the door, which is accessed through a front approach and which has both a closer and a latch, is inaccessible because it has only 3 inches of clear space on the latch side. | D7 | 6 months |
12.3.e. | No accessible mirror has been provided. | TR14 | 6 months |
12.3.f. | The designated accessible toilet is inaccessible because its centerline is 18 ½ inches from the side wall. | ST17 | 6 months |
12.3.g. | The toilet paper dispenser is inaccessible because it is mounted 39 inches from the rear wall. | SU17 | 6 months |
13. | Fox Point Library - 90 Ives Street | ||
13.1. | Drinking Fountain | ||
13.1.a. | The drinking fountain is inaccessible because it has a spout that is 39 inches high. | DF6 | 6 months |
13.1.b. | The drinking fountain is inaccessible because the flow of water is ½ inch high. | DF7 | 6 months |
13.1.c. | The drinking fountain is inaccessible because the water flow is 5 ¼ inches from the front of the fountain. | DF1 | 6 months |
13.1.d. | The drinking fountain is inaccessible because the controls require 11 pounds of force to operate. | DF2 | 6 months |
13.1.e. | The drinking fountain is inaccessible because it provides only 20 ½ inches of clear knee height. | DF5 | 6 months |
13.1.f. | There is no drinking fountain provided for people who have difficulty bending or stooping. | DF3 | 6 months |
13.2. | Men’s Toilet Room (Stalls) | ||
13.2.a. | The toilet room sign is mounted on the door and has no raised or Braille characters. | TR17 | 6 months |
13.2.b. | The designated accessible toilet stall is inaccessible because it is only 36 inches wide. | ST16 | 6 months |
13.2.c. | The door is inaccessible because it has an opening width of only 29 inches. | D25 | 6 months |
13.2.d. | The pull side of the door, which is accessed through a front approach, is inaccessible because it does not have adequate clear space on the latch side. | D6 | 6 months |
13.2.e. | No accessible mirror has been provided. | TR14 | 6 months |
13.2.f. | No accessible coat hook has been provided. | TR1 | 6 months |
13.2.g. | The urinal is inaccessible because the rim is 24 inches high and the flush valve is 52 inches high. | TR20 | 6 months |
13.2.h. | The designated accessible toilet is inaccessible because its centerline is 19 ½ inches from the side wall. | ST17 | 6 months |
13.2.i. | The toilet is inaccessible because there are no horizontal grab bars provided. | SU11 | 6 months |
13.3. | Elevator | ||
13.3.a. | The elevator is inaccessible because the hall call buttons are mounted 38 inches high. | E3 | 6 months |