ATTACHMENT K: Program Access in Existing Facilities Please Note: Paragraph 53 of the Agreement requires that within three months of the effective date of this Agreement, the City will provide signage as necessary to comply with 28 C.F.R. § 35.163(b), after having surveyed all facilities that are the subject of this Agreement for the purpose of identifying those that have multiple entrances not all of which are accessible. The technical requirements and, where appropriate, the scoping requirements of the Standards are used as a guide for determining whether a program or activity held in an existing facility is "readily accessible to and usable by" persons with disabilities and for determining what changes are necessary to make this program or activity accessible if it continues to be provided in the existing facility in question. See 28 C.F.R. §§ 35.150(b)(1), 35.151. The chart below lists the facilities surveyed by the Department, the access issues identified during the survey, and the actions required to correct the access issues. Required actions are listed using an alphanumeric code. The key to the alphanumeric codes is provided in Attachment M to this Agreement. In order to ensure that the programs, services, and activities housed in the City's facilities are accessible to persons with disabilities, when viewed in their entirety, the City will take the actions referenced by the alphanumeric code and described in detail in Attachment M to this Settlement Agreement within the time period specified below, which time period begins to run on the effective date of the Agreement. |
|||
Item # |
Access Issue |
Required Action |
Completion Date |
---|---|---|---|
1. |
City Hall, located at 200 Highway East, Poplarville, MS 39470 |
||
1.1. |
Parking |
||
1.1.a. |
The parking lot is inaccessible because it has no designated van accessible space. This lot requires 1 van accessible space. |
P3 |
24 months |
1.1.b. |
The designated accessible parking is inaccessible because it lacks vertical "van-accessible" signage. |
P6 |
24 months |
1.1.c. |
The designated accessible parking is inaccessible because the access aisle is 53 inches wide. |
P8 |
24 months |
1.2. |
Accessible Route: From Parking lot to Entrance |
||
1.2.a. |
The built-up curb ramp impermissibly extends into the required parking space's access aisle. |
AR4 |
24 months |
1.2.b. |
The route is inaccessible because there is a change in level of 1¾ inches between the concrete and the red tiled area. |
AR1 |
24 months |
1.2.c. |
The route to the main entrance door is inaccessible because the slope of the 5 inch high apron at the entrance door landing is 16%. |
AR1 |
24 months |
1.3. |
Exterior Entrance and Doors: The door is inaccessible because there is a slope of 16% within the door's required maneuvering clearance. |
D13 |
24 months |
1.4. |
Main Counter: The counter is inaccessible because it is 40 inches high. |
C6 |
24 months |
1.5. |
Board Meeting Room: The route to the Board Meeting room is inaccessible because it is 24 inches wide. |
AR3 |
24 months |
2. |
Poplarville Police Department, located 305 Highway 26 East, Poplarville, MS 39470 |
||
2.1. |
Exterior Entrance and Doors |
||
2.1.a. |
The door is inaccessible because there is a 3½ inch high threshold. |
D23 |
24 months |
2.1.b. |
The door is inaccessible because knob hardware is used. |
D1 |
24 months |
2.2. |
Accessible Route From Entrance to Interview Room: The route is inaccessible because it is only 30 inches wide. |
AR3 |
24 months |
2.3. |
Investigator's Office: The door is inaccessible because knob hardware is used. |
D1 |
24 months |
3. |
Chamber of Commerce, located at 101 N Main, Poplarville, MS 39470 |
||
3.1. |
Exterior Entrances and Doors |
||
3.1.a. |
The door is inaccessible because knob hardware is used. |
D1 |
24 months |
3.1.b. |
The door is inaccessible because there is a 1¾ inch high threshold. |
D23 |
24 months |
4. |
Poplarville Library, located at 206 N Jackson St, Poplarville, MS 39470 |
||
4.1. |
Parking |
||
4.1.a. |
The designated van accessible parking space is inaccessible because it lacks vertical "van-accessible" signage. |
P6 |
36 months |
4.1.b. |
The parking lot is inaccessible because the pavements markings designating accessible parking spaces are unclear. |
P3, M1 |
36 months |
4.1.c. |
The designated accessible parking is inaccessible because the designated van accessible space (at the end of the parking lot) slopes 2.7%, and the other designated accessible space (farther from the end of the parking lot) has a cross slope of 3.3%. |
P7
|
36 months |
4.2. |
Accessible Route: From Parking to Entrance |
||
4.2.a. |
The built-up curb ramp is inaccessible because it has a slope of 10.5% |
AR5 |
36 months |
4.2.b. |
The built-up curb ramp impermissibly extends into the required parking space's access aisle. |
AR4 |
36 months |
4.2.c. |
The route is inaccessible because it slopes up to 7.7% and has cross slopes up to 9.4% |
AR1 |
36 months |
4.3. |
Exterior Entrance and Doors: The door is inaccessible because there is a slope of 5.1% within the door's required maneuvering clearance. |
D13 |
36 months |
4.4. |
Library Interior |
||
4.4.a. |
The computer desks are inaccessible because they are 25 inches high to the bottom. |
LB4 |
36 months |
4.4.b. |
The check-out area is inaccessible because the counter is 39 inches high. |
LB2 |
36 months |
4.4.c. |
The magazine displays are inaccessible because they are 68 inches high to the top. |
LB1 |
36 months |
4.5. |
Women's Toilet Room: Single-User |
||
4.5.a. |
The toilet room is inaccessible because there is insufficient turning space provided within the room. |
TR19 |
36 months |
4.5.b. |
The toilet room sign is mounted on the door and has no raised or Braille characters. |
TR17 |
36 months |
4.5.c. |
The door is inaccessible because knob hardware is used. |
D1 |
36 months |
4.5.d. |
The door is inaccessible because it requires 10 pounds of force to open. |
D2 |
36 months |
4.5.e. |
The pull side of the door, which is accessed through a front approach, is inaccessible because it has only 15 inches of clear space on the latch side. |
D6 |
36 months |
4.5.f. |
The push side of the door, which is accessed through a front approach and which has both a closer and a latch, is inaccessible because it has only 8¼ inches of clear space on the latch side. |
D7 |
36 months |
4.5.g. |
No accessible mirror has been provided. |
TR14 |
36 months |
4.5.h. |
The paper towel dispenser is inaccessible because it is mounted with the controls 59 inches high. |
TR5 |
36 months |
4.5.i. |
The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact. |
TR12 |
36 months |
4.5.j. |
The lavatory is inaccessible because it has twist-type hardware. |
TR10 |
36 months |
4.5.k. |
The toilet is inaccessible because the flush control is on the closed side. |
SU1 |
36 months |
4.5.l. |
The toilet is inaccessible because the top of the seat is 19¼ inches above the finished floor. |
SU18 |
36 months |
4.5.m. |
The toilet is inaccessible because its centerline is 17½ inches from the side wall. |
SU15 |
36 months |
4.5.n. |
The side grab bar at the toilet is inaccessible because it is 30 inches long and the far end is mounted 41 inches from the rear wall. |
SU6 |
36 months |
4.5.o. |
The toilet is inaccessible because there is no rear grab bar provided. |
SU2 |
36 months |
4.6. |
Men's Toilet Room: Single-User |
||
4.6.a. |
The toilet room is inaccessible because there is insufficient turning space provided within the room. |
TR19 |
36 months |
4.6.b. |
The toilet room sign is mounted on the door and has no raised or Braille characters. |
TR17 |
36 months |
4.6.c. |
The door is inaccessible because knob hardware is used. |
D1 |
36 months |
4.6.d. |
The door is inaccessible because it requires 7 pounds of force to open. |
D2 |
36 months |
4.6.e. |
The pull side of the door, which is accessed through a front approach, is inaccessible because it has only 11 inches of clear space on the latch side. |
D6 |
36 months |
4.6.f. |
The push side of the door, which is accessed through a front approach and which has both a closer and a latch, is inaccessible because it has only 8¼ inches of clear space on the latch side. |
D7 |
36 months |
4.6.g. |
No accessible mirror has been provided. |
TR14 |
36 months |
4.6.h. |
The paper towel dispenser is inaccessible because it is mounted 59 inches high. |
TR5 |
36 months |
4.6.i. |
The lavatory is inaccessible because the bottom of the apron is 28½ inches high. |
TR11 |
36 months |
4.6.j. |
The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact. |
TR12 |
36 months |
4.6.k. |
The lavatory is inaccessible because it has twist-type hardware. |
TR10 |
36 months |
4.6.l. |
The side grab bar at the toilet is inaccessible because it is 30 inches long and the far end is mounted 41 inches from the rear wall. |
SU6 |
36 months |
4.6.m. |
The toilet is inaccessible because there is no rear grab bar provided. |
SU2 |
36 months |
4.7. |
Drinking Fountain Between Toilet Rooms |
||
4.7.a. |
The drinking fountain is inaccessible because the controls require 10 pounds of force to operate. |
DF2 |
36 months |
4.7.b. |
The wall-mounted drinking fountain is inaccessible because it does not provide sufficient clear knee space height. |
DF5 |
36 months |
4.8. |
Meeting Room: The door is inaccessible because knob hardware is used. |
D1 |
36 months |