ATTACHMENT K (2): Program Access in Existing FacilitiesPlease Note: Paragraph 45 of the Agreement requires that within six months of the effective date of this Agreement, the County will provide signage as necessary to comply with 28 C.F.R. § 35.163(b), after having surveyed all facilities that are the subject of this Agreement for the purpose of identifying those that have multiple entrances not all of which are accessible. The technical requirements and, where appropriate, the scoping requirements of the Standards are used as a guide for determining whether a program or activity held in an existing facility is "readily accessible to and usable by" persons with disabilities and for determining what changes are necessary to make this program or activity accessible if it continues to be provided in the existing facility in question. See 28 C.F.R. §§ 35.150(b)(1), 35.151. The chart below lists the facilities surveyed by the Department, the access issues identified during the survey, and the actions required to correct the access issues. Required actions are listed using an alphanumeric code. The key to the alphanumeric codes is provided in Attachment M to this Agreement. In order to ensure that the programs, services, and activities housed in the County's facilities are accessible to persons with disabilities, when viewed in their entirety, the County will take the actions referenced by the alphanumeric code and described in detail in Attachment M to this Settlement Agreement within the time period specified below, which time period begins to run on the effective date of the Agreement. |
|||
Item # |
Access Issue |
Required Action |
Completion Date |
1. |
Pennington County Public Health Building, located at 725 North Lacrosse, Rapid City, South Dakota 57701 |
||
1.1. |
Parking: |
||
1.1.1. |
The designated accessible parking spaces are inaccessible because the vertical signs are mounted 40 inches high. |
P3 |
30 months |
1.1.2. |
The designated accessible parking space (#1/left) is inaccessible because the cross slope is of 4.1%. |
P4 |
30 months |
1.2. |
Exterior Accessible Route to the Veterans Services Office (VA): This area is inaccessible because the defibrillator protrudes into the walkway and is not detectable to blind persons using a cane. |
AR7 |
30 months |
1.3. |
Door Hardware: The doors throughout the facility are inaccessible because the knob hardware requires tight grasping, pinching, or twisting of the wrist to operate. |
D2 |
30 months |
1.4. |
Toilet Room Directional Signage: The signage provided is inaccessible because it does not have raised and Braille characters. |
D15 |
30 months |
1.5. |
Women's Lobby Toilet Room: |
||
1.5.1. |
The toilet room is inaccessible because the sign has no raised or Braille characters and is mounted on the door. |
TR11 |
30 months |
1.5.2. |
The lavatory is inaccessible because the water supply and drain pipes are not insulated or otherwise configured to protect against contact. |
LS2 |
30 months |
1.5.3. |
The toilet room is inaccessible because there is no standard accessible toilet compartment provided. |
TR2 |
30 months |
1.5.4. |
The toilet is inaccessible because the centerline is 20 inches from the side wall. |
TR7 |
30 months |
1.5.5. |
The toilet is inaccessible because the top of the seat is 20 inches high. |
TR9 |
30 months |
1.5.6. |
The toilet is inaccessible because the flush control is on the closed side. |
TR4 |
30 months |
1.5.7. |
The baby changing table is inaccessible because it protrudes into the clear floor space of the door and has |
DW1 |
30 months |
1.6. |
Men's Lobby Toilet Room: |
||
1.6.1. |
The toilet room is inaccessible because the sign has no raised or Braille characters and is mounted on the door. |
TR11 |
30 months |
1.6.2. |
The toilet room has insufficient maneuvering clearance at the entrance and is not accessible to people with disabilities. |
TR1 |
30 months |
1.6.3. |
The lavatory is inaccessible because the water supply and drain pipes are not insulated or otherwise configured to protect against contact. |
LS2 |
30 months |
1.6.4. |
The toilet room is inaccessible because there is no standard accessible toilet compartment provided. |
TR2 |
30 months |
1.6.5. |
The toilet is inaccessible because the centerline is 19 inches from the side wall. |
TR7 |
30 months |
1.6.6. |
The toilet is inaccessible because the top of the seat is 20 inches high. |
TR9 |
30 months |
1.6.7. |
The toilet is inaccessible because the flush control is on the closed side. |
TR4 |
30 months |
1.6.8. |
The urinal is inaccessible because the rim is 24 inches high. |
TR8 |
30 months |
1.7. |
Alcohol and Drug Program Reception Area: Drinking Fountain |
||
1.7.1. |
Although a designated accessible drinking fountain is provided, there is no drinking fountain provided for people who have difficulty bending or stooping. |
DF3 |
30 months |
1.8. |
Women's Toilet Room-Alcohol and Drug Program: |
||
1.8.1. |
The toilet room is inaccessible because the sign has no raised or Braille characters and is mounted on the door. |
TR11 |
30 months |
1.8.2. |
The door is inaccessible because it requires 9 pounds of force to open. |
D3 |
30 months |
1.8.3. |
The toilet room is inaccessible because there is no standard accessible toilet compartment provided. |
TR2 |
30 months |
1.8.4. |
The toilet is inaccessible because the centerline is 19 inches from the side wall. |
TR7 |
30 months |
1.8.5. |
The toilet is inaccessible because the top of the seat is 20 inches high. |
TR9 |
30 months |
1.8.6. |
The toilet paper dispenser is inaccessible because it is mounted 12 inches from the front of the toilet. |
TR6 |
30 months |
1.9. |
Men's Toilet Room-Alcohol and Drug Program: |
||
1.9.1. |
The toilet room is inaccessible because the sign has no raised or Braille characters and is mounted on the door. |
TR11 |
30 months |
1.9.2. |
The door is inaccessible because it requires 8 pounds of force to open. |
D3 |
30 months |
1.9.3. |
The toilet room has insufficient maneuvering clearance at the entrance and is not accessible to people with disabilities. |
TR1 |
30 months |
1.9.4. |
The lavatory is inaccessible because the water supply and drain pipes are not insulated or otherwise configured to protect against contact. |
LS2 |
30 months |
1.9.5. |
The toilet room is inaccessible because there is no standard accessible toilet compartment provided. |
TR2 |
30 months |
1.9.6. |
The toilet is inaccessible because the centerline is 16 inches from the side wall. |
TR7 |
30 months |
1.9.7. |
The toilet is inaccessible because the top of the seat is 20 inches high. |
TR9 |
30 months |
1.9.8. |
The urinal is inaccessible because the rim is 24 inches high. |
TR8 |
30 months |
1.9.9. |
The toilet paper dispenser is inaccessible because it is mounted 12 inches from the front of the toilet. |
TR6 |
30 months |
1.10. |
Detox Center Drop-Off (lower Level) |
||
1.10.1. |
The parking is inaccessible because it has no van accessible parking space. |
P5 |
30 months |
1.11. |
Unisex Shower and Locker Room/with Toilet Room Stalls |
||
1.11.1. |
The shower/toilet room is inaccessible because the sign has no raised or Braille characters. |
TR11 |
30 months |
1.11.2. |
There is no accessible shower provided. |
B2 |
30 months |
1.11.3. |
There is no accessible locker provided. |
LR3 |
30 months |
1.11.4. |
There is no accessible lavatory provided. |
LS1 |
30 months |
1.11.5. |
The toilet room is inaccessible because there is no standard accessible toilet compartment provided. |
TR2 |
30 months |
1.11.6. | The paper towel dispenser is inaccessible because it is mounted with the controls 57 inches high. |
TR6 |
30 months |
2. |
Pennington Highway Services Building,7070 Highway 385, Hill City, South Dakota57701 |
||
2.1. |
Parking: The designated accessible parking spaces are inaccessible because the vertical signs are mounted 25 inches high. |
P3 |
30 months |
2.1.1. |
The designated accessible parking space is inaccessible because it has no access aisles. (Striping fading) |
P2 |
30 months |
2.1.2. |
The parking lot is inaccessible because it has no van accessible parking space. |
P5 |
30 months |
3. |
Pennington Juvenile Services Center,3505 Cambell Street, Rapid City, South Dakota 57701 |
||
3.1. |
Parking: The designated accessible parking space #3 is inaccessible because it slopes of up to 3.4%. |
P4 |
30 months |
3.1.1. |
The designated accessible parking space #4 is inaccessible because they have slopes of up to 2.9% and cross slopes of up to 2.9%. |
P4 |
30 months |
3.1.2. |
The designated accessible parking space #4 access aisle is inaccessible because it slopes of up to 4.1%. |
P4 |
30 months |
3.1.3. |
The designated accessible parking spaces #3 and #4 are inaccessible because the access aisles do not extend the full length. |
P2 |
30 months |
3.2. |
Lobby Unisex Toilet Room |
||
3.2.1. |
The door is inaccessible because it requires 8 pounds of force to open. |
D3 |
30 months |
3.3. |
Unisex Single User Minimum Security Area |
||
3.3.1. |
The toilet room contains a number of inaccessible elements and is not accessible to people with disabilities. |
TR1 |
30 months |
3.4. |
Shower area-Minimum Security Area |
||
3.4.1. |
The shower room is inaccessible because the sign has no raised or Braille characters and is mounted on above the door. |
TR11 |
30 months |
3.4.2. |
There is no accessible shower provided. |
B2 |
30 months |
3.5. |
Pod C |
||
3.5.1. |
The shower room is inaccessible because the sign has no raised or Braille characters and is mounted on above the door. |
TR11 |
30 months |
3.5.2. |
There is no accessible shower provided. |
B2 |
30 months |
3.5.3. |
There is no accessible bathtub provided. |
B1 |
30 months |
4. |
Walter Taylor Building, 601 East Center Street, Rapid City, South Dakota57701 (also a Polling Place) |
||
4.1. |
Parking: The designated accessible parking spaces are inaccessible because the vertical signs are mounted less than 60 inches high. |
P3 |
30 months |
4.1.1. | The parking lot is inaccessible because it has no van accessible signage. |
P5 |
30 months |
4.2. |
Exterior Entrance door from accessible parking space: |
||
4.2.1. |
The door is inaccessible because it has a 2 inch threshold. |
D12 |
30 months |
4.3. |
Women's Toilet Room (with Stalls) |
||
4.3.1. |
The directional signage provided is inaccessible because it is mounted above the doors and does not have raised and Braille characters. |
D15 |
30 months |
4.3.2. |
The toilet room is inaccessible because the sign is mounted 57 inches to bottom of the tactile characters. |
TR11 |
|
4.3.3. |
The toilet is inaccessible because the top of the seat is 16 inches high. |
TR9 |
30 months |
4.3.4. |
The toilet is inaccessible because the side grab bar is 50 inches long and it is mounted with the far end 6 inches from the rear wall. |
TR17 |
30 months |
4.4. |
Men's Toilet Room (with Stalls) |
||
4.4.1. |
The directional signage provided is inaccessible because it is mounted above the doors and does not have raised and Braille characters. |
D15 |
30 months |
4.4.2. |
The toilet room is inaccessible because the sign is mounted 56 inches to bottom of the tactile characters. |
TR11 |
|
4.4.3. |
The urinal is inaccessible because the rim is 23 1/2 inches high and the flush control is 51 inches high. |
TR8 |
30 months |
4.4.4. |
The toilet is inaccessible because the flush control is on the closed side. |
TR4 |
30 months |
4.4.5. |
The toilet is inaccessible because the side grab bar is 49 inches long and it is mounted with the far end 6 inches from the rear wall. |
TR17 |
30 months |
4.5. |
Drinking Fountain between the Men's and Women's Toilet Room |
||
4.5.1. |
This area is inaccessible because the drinking fountain protrudes into the walkway and is not detectable to blind persons using a cane. |
AR7 |
30 months |
5. |
FAIRGROUNDS, 801 San Francisco Street, Rapid City, South Dakota57701 (also a Polling Place) |
||
5.1. |
Central States Fair office (Accessible entrance and parking on South Side of the building) |
||
5.1.1. |
The parking lot, with a total of 27 parking spaces has no designated standard accessible spaces provided.This lot requires 1van accessible space and 1standard accessible spaces. |
P1 |
30 months |
5.1.2. |
The parking lot is inaccessible because it has no van accessible parking space signage. |
P5 |
30 months |
5.2. |
South Side Entrance Ramp |
||
5.2.1. |
The ramp is inaccessible because it does not have edge protection. |
R3 |
30 months |
5.3. |
Women's Single User Toilet Room |
||
5.3.1. |
The toilet room is inaccessible because the sign has no raised or Braille characters and is mounted on the door. |
TR11 |
30 months |
5.3.2. |
No accessible mirror has been provided. |
TR5 |
30 months |
5.3.3. |
The lavatory is inaccessible because the water supply and drain pipes are not insulated or otherwise configured to protect against contact. |
LS2 |
30 months |
5.3.4. |
The paper towel dispenser is inaccessible because it is mounted with the controls 43 inches high. |
CT4 |
30 months |
5.3.5. |
The lavatory is inaccessible because the paper towel dispenser protrudes 8 1/2 inches into the clear floor space of the lavatory and is not detectable to blind persons using a cane. |
AR7 |
30 months |
5.3.6. |
The paper towel dispenser is inaccessible because the controls require twisting of the wrist to operate. |
CT2 |
30 months |
5.3.7. |
The toilet is inaccessible because the flush control is on the closed side. |
TR4 |
30 months |
5.3.8. |
The toilet is inaccessible because the side grab bar is 36 inches long and it is mounted with the far end 48 inches from the rear wall. |
TR17 |
30 months |
5.3.9. |
The toilet is inaccessible because the rear grab bar is 30 inches long. |
TR14 |
30 months |
5.4. |
Men's Single User Toilet Room |
||
5.4.1. |
The toilet room is inaccessible because the sign has no raised or Braille characters and is mounted on the door. |
TR11 |
30 months |
5.4.2. |
No accessible mirror has been provided. |
TR5 |
30 months |
5.4.3. |
The lavatory is inaccessible because the water supply and drain pipes are not insulated or otherwise configured to protect against contact. |
LS2 |
30 months |
5.4.4. |
The paper towel dispenser is inaccessible because it is mounted with the controls 47 inches high. |
CT4 |
30 months |
5.4.5. |
The lavatory is inaccessible because the paper towel dispenser protrudes 8 inches into the clear floor space of the lavatory and is not detectable to blind persons using a cane. |
AR7 |
30 months |
5.4.6. |
The paper towel dispenser is inaccessible because the controls require twisting of the wrist to operate. |
CT2 |
30 months |
5.5. |
Creative Arts Building (also polling) |
||
5.5.1. |
Unisex Toilet Room (right side of entrance) |
||
5.5.2. |
The toilet room is inaccessible because there is no signage with raised or Braille characters. |
TR 11 |
30 months |
5.5.3. |
The paper towel dispenser is inaccessible because it is mounted with the controls 43 inches high. |
CT4 |
30 months |
5.5.4. |
The paper towel dispenser is inaccessible because the controls require twisting of the wrist to operate. |
CT2 |
30 months |
5.5.5. |
The lavatory is inaccessible because the paper towel dispenser protrudes 8 inches into the clear floor space of the lavatory and is not detectable to blind persons using a cane. |
AR7 |
30 months |
5.5.6. |
The toilet is inaccessible because the flush control is on the closed side. |
TR4 |
30 months |
5.5.7. |
The coat hook is inaccessible because it is mounted 56 inches high. |
TR3 |
30 months |
5.6. |
Unisex Toilet Room (left side of entrance) |
||
5.6.1. |
The toilet room is inaccessible because there is no signage with raised or Braille characters. |
TR11 |
30 months |
5.6.2. |
The paper towel dispenser is inaccessible because it is mounted with the controls 43 inches high. |
CT4 |
30 months |
5.6.3. |
The paper towel dispenser is inaccessible because the controls require twisting of the wrist to operate. |
CT2 |
30 months |
5.6.4. |
The lavatory is inaccessible because the paper towel dispenser protrudes 8 inches into the clear floor space of the lavatory and is not detectable to blind persons using a cane. |
AR7 |
30 months |
5.6.5. |
The toilet is inaccessible because the flush control is on the closed side. |
TR4 |
30 months |
5.7. |
Fine Arts Building (polling place) |
||
5.7.1. |
Parking: The building provides 9 temporary accessible parking during one week in August for State Fair: |
P1 |
30 months |
5.8. |
Accessible Route: The route from the accessible parking to the entrance is inaccessible because it has a slope of 5.9%. |
AR1 |
30 months |
5.9. |
Unisex Toilet Room |
||
5.9.1. |
The signage provided is inaccessible because it is mounted on the door and does not have raised and Braille characters. |
D15 |
30 months |
5.9.2. |
The paper towel dispenser is inaccessible because it is mounted with the controls 43 inches high. |
CT4 |
30 months |
5.9.3. |
The paper towel dispenser is inaccessible because the controls require twisting of the wrist to operate. |
CT2 |
30 months |
5.9.4. |
The paper towel dispenser protrudes 9 inches into the clear floor space of the water closet and is not detectable to blind persons using a cane. |
AR7 |
30 months |
5.9.5. |
The soap dispenser protrudes 7 1/2 inches into the clear floor space of the water closet and is not detectable to blind persons using a cane. |
AR7 |
30 months |
5.9.6. |
The toilet is inaccessible because the flush control is on the closed side. |
TR4 |
30 months |
5.9.7. |
The toilet is inaccessible because the side grab bar is 48 inches long and it is mounted with the far end 6 inches from the rear wall. |
TR17 |
30 months |
5.10. |
James Kjerstad Event Center |
||
5.10.1. |
Parking: The designated accessible parking spaces are inaccessible because there are no vertical signs. |
P3 |
30 months |
5.10.2. |
The parking lot, with a total of 300 parking spaces has 4 standard designated accessible parking spaces.This lot requires 2 van accessible space and 6 standard accessible spaces. |
P1 |
30 months |
5.10.3. |
The curb ramps are inaccessible because they have slopes of 12. % and 11.3%. |
AR4 |
30 months |
5.11. |
Ramps: There are two ramps on each side of the stadium seating. The ramps are inaccessible because the handrails do not have 12 inch long extensions at the ends. |
R2 |
30 months |
5.12. |
Assistive Listening System: The arena is inaccessible because there is no assistive listening system provided. This area has 3,630 seats it requires 55, plus 1 receiver per 100 seats over 2000. |
AA4 |
30 months |
5.13. |
Concessions: There are no accessible food service counters. |
C1 |
30 months |
5.14. |
Men's Toilet Room with Stalls (East) |
||
5.14.1. |
The signage provided is inaccessible because it is mounted on the door. |
D15 |
30 months |
5.14.2. |
The door is inaccessible because it requires 10 pounds of force to open. |
D3 |
30 months |
5.14.3. |
The lavatories are inaccessible because the water supply and drain pipes are not insulated or otherwise configured to protect against contact. |
LS2 |
30 months |
5.14.4. |
The air dryer is inaccessible because it is mounted with the controls 39 inches high. |
CT4 |
30 months |
5.14.5. |
The air dryer protrudes 8 inches into the clear floor space and is not detectable to blind persons using a cane. |
AR7 |
30 months |
5.14.6. |
The toilet is inaccessible because the side grab bar is 48 inches long and it is mounted with the far end 6 inches from the rear wall. |
TR17 |
30 months |
5.15. |
Women's Toilet Room with Stalls (East) |
||
5.15.1. |
The signage provided is inaccessible because it is mounted on the door. |
D15 |
30 months |
5.15.2. |
The door is inaccessible because it requires 13 pounds of force to open. |
D3 |
30 months |
5.15.3. |
The lavatories are inaccessible because the water supply and drain pipes are not insulated or otherwise configured to protect against contact. |
LS2 |
30 months |
5.15.4. |
The toilet room is inaccessible because, although there are 10 stalls provided, there is no ambulatory stall provided. |
TR22 |
30 months |
5.15.5. |
The air dryer is inaccessible because it is mounted with the controls 39 inches high. |
CT4 |
30 months |
5.15.6. |
The air dryer protrudes 8 inches into the clear floor space and is not detectable to blind persons using a cane. |
AR7 |
30 months |
5.16. |
Men's Toilet Room (West) |
||
5.16.1. |
The signage provided is inaccessible because it is mounted on the door. |
D15 |
30 months |
5.16.2. |
The door is inaccessible because it requires 13 pounds of force to open. |
D3 |
30 months |
5.16.3. |
The lavatories are inaccessible because the water supply and drain pipes are not insulated or otherwise configured to protect against contact. |
LS2 |
30 months |
5.16.4. |
The toilet room is inaccessible because, although there are 10 stalls provided, there is no ambulatory stall provided. |
TR22 |
30 months |
5.16.5. |
The air dryer is inaccessible because it is mounted with the controls 39 inches high. |
CT4 |
30 months |
5.16.6. |
The air dryer protrudes 8 inches into the clear floor space and is not detectable to blind persons using a cane. |
AR7 |
30 months |
5.17. |
Women's Toilet Room (West) |
||
5.17.1. |
The signage provided is inaccessible because it is mounted on the door. |
D15 |
30 months |
5.17.2. |
The door is inaccessible because it requires 13 pounds of force to open. |
D3 |
30 months |
5.17.3. |
The lavatories are inaccessible because the water supply and drain pipes are not insulated or otherwise configured to protect against contact. |
LS2 |
30 months |
5.17.4. |
The toilet room is inaccessible because, although there are 10 stalls provided, there is no ambulatory stall provided. |
TR22 |
30 months |
5.17.5. |
The air dryer is inaccessible because it is mounted with the controls 39 inches high. |
CT4 |
30 months |
5.17.6. |
The air dryer protrudes 8 inches into the clear floor space and is not detectable to blind persons using a cane. |
AR7 |
30 months |