ATTACHMENT K: Program Access in Existing Facilities Please Note: Paragraph 55 of the Agreement requires that within three months of the effective date of this Agreement, the County will provide signage as necessary to comply with 28 C.F.R. § 35.163(b), after having surveyed all facilities that are the subject of this Agreement for the purpose of identifying those that have multiple entrances not all of which are accessible. The technical requirements and, where appropriate, the scoping requirements of the Standards are used as a guide for determining whether a program or activity held in an existing facility is " readily accessible to and usable by" persons with disabilities and for determining what changes are necessary to make this program or activity accessible if it continues to be provided in the existing facility in question. See 28 C.F.R. §§ 35.150(b)(1), 35.151. The chart below lists the facilities surveyed by the Department, the access issues identified during the survey, and the actions required to correct the access issues. Required actions are listed using an alphanumeric code. The key to the alphanumeric codes is provided in Attachment M to this Agreement. In order to ensure that the programs, services, and activities housed in the County´s facilities are accessible to persons with disabilities, when viewed in their entirety, the County will take the actions referenced by the alphanumeric code and described in detail in Attachment M to this Settlement Agreement within the time period specified below, which time period begins to run on the effective date of the Agreement. |
|||
Item # |
Access Issue |
Required Action |
Completion Date |
---|---|---|---|
1. |
Courthouse, located at 200 South Main Street, Poplarville |
||
1.1. |
Parking: |
||
1.1.a. |
The parking lot, with a total of approximately 25 parking spaces, is inaccessible because there is no designated van accessible space, and the pavement markings for the accessible spaces are not clear. This lot requires one (1) van accessible space. |
P3 |
24 months |
1.1.b. |
Far Right Space: |
||
1.1.b.1) |
The designated accessible parking is inaccessible because the sign is mounted too low and does not indicate the space is van accessible. |
P6 |
24 months |
1.1.b.2) |
The designated accessible parking is inaccessible because there is no access aisle. |
P1 |
24 months |
1.1.c. |
Center Space: |
||
1.1.c.1) |
The designated accessible parking is inaccessible because the sign is mounted too low. |
P6 |
24 months |
1.1.c.2) |
The designated accessible parking is inaccessible because it slopes 2.6%. |
P7 |
24 months |
1.1.d. |
Far Left Space: |
||
1.1.d.1) |
The designated accessible parking is inaccessible because it lacks vertical signage. |
P6 |
24 months |
1.1.d.2) |
The designated accessible parking is inaccessible because it slopes 2.8% and has a cross slope of 2.8%. |
P7 |
24 months |
1.2. |
Route from Parking to Sidewalk: The built-up curb ramp is inaccessible because it has a slope of 17.1%, a rise of 7 inches, lacks flared sides, and impermissibly extends into the required parking space´s access aisle. |
AR4, AR5 |
24 months |
1.3. |
Ramp to East Entrance: The ramp is inaccessible because the handrails are mounted 33 inches above the ramp surface and do not extend at least 12 inches beyond the top and bottom of the ramp parallel with the ground surface. |
R4 |
24 months |
1.4. |
Entrances: |
||
1.4.a. |
The building is inaccessible because fewer than 50% of its entrances are accessible. |
D12 |
24 months |
1.4.b. |
The building does not have directional signage posted at inaccessible entrances and does not have the International Symbol of Accessibility posted at accessible entrances. |
D16 |
24 months |
1.5. |
Central Elevators: |
||
1.5.a. |
The elevator is inaccessible because the hall lanterns do not emit an audible signal indicating when a car is answering a call. |
E11 |
24 months |
1.5.b. |
The elevator is inaccessible because the doors of the car do not open and close automatically. |
E6 |
24 months |
1.5.c. |
The elevator is inaccessible because the emergency controls are not grouped at the bottom of the panel. |
E9 |
24 months |
1.6. |
Sheriff´s Office: |
||
1.6.a. |
The door is inaccessible because it requires 9 pounds of force to open. |
D2 |
24 months |
1.6.b. |
The door is inaccessible because knob hardware is used. |
D1 |
24 months |
1.6.c. |
The push side of the door, which is accessed through a front approach and which has both a closer and a latch, is inaccessible because it has no clear space on the latch side. |
D7 |
24 months |
1.7. |
Chancery Clerk´s Office: |
||
1.7.a. |
The two doors are inaccessible because knob hardware is used. |
D1 |
24 months |
1.7.b. |
The push side of each door, which is accessed through a front approach and which has both a closer and a latch, is inaccessible because it has no clear space on the latch side. |
D7 |
24 months |
1.8. |
First Floor Men´s Toilet Room: |
||
1.8.a. |
The toilet room sign is mounted on the door and has no raised or Braille characters. |
TR17 |
24 months |
1.8.b. |
The urinal is inaccessible because the rim is not 17 inches or less above the finished floor and the flush control is 52 inches above the finished floor. |
TR20 |
24 months |
1.8.c. |
The designated accessible toilet is inaccessible because its centerline is 16 inches from the side wall. |
ST17 |
24 months |
1.8.d. |
The designated accessible toilet is inaccessible because the flush control is on the closed side. |
ST2 |
24 months |
1.8.e. |
The toilet paper dispenser in the designated accessible stall is inaccessible because it is mounted 42 inches from the rear wall. |
ST19 |
24 months |
1.8.f. |
No accessible coat hook has been provided. |
TR1 |
24 months |
1.8.g. |
The designated accessible toilet stall is inaccessible because it is not at least 60 inches wide and at least 56 inches deep. |
ST16 |
24 months |
1.8.h. |
The soap dispenser is inaccessible because it is mounted 52 inches high. |
TR4 |
24 months |
1.9. |
First Floor Women´s Toilet Room: |
||
1.9.a. |
The toilet room sign is mounted on the door and has no raised or Braille characters. |
TR17 |
24 months |
1.9.b. |
The designated accessible toilet is inaccessible because its centerline is 14 inches from the side wall. |
ST17 |
24 months |
1.9.c. |
No accessible coat hook has been provided. |
TR1 |
24 months |
1.10. |
Second Floor Unisex Single User Toilet Room: |
||
1.10.a. |
The toilet room contains a number of inaccessible elements and is not accessible to people with disabilities. |
SU13 |
24 months |
1.10.b. |
No accessible coat hook has been provided. |
TR1 |
24 months |
1.10.c. |
Although the facility contains an emergency alarm system, the alarm system is inaccessible because there are no visual alarms provided in toilet room. |
AL1 |
24 months |
1.11. |
Second Floor Route to Courtroom: The route to the courtroom is inaccessible because it is only 30.5 inches wide when passing through the metal detector. |
AR3, M2 |
24 months |
1.12. |
Second Floor Courtroom: |
||
1.12.a. |
The door is inaccessible because knob hardware is used. |
D1 |
24 months |
1.12.b. |
The courtroom, containing 163 seats, is inaccessible because only 1 wheelchair seating area is provided. A total of 4 wheelchair seating areas are required. |
AA6 |
24 months |
1.12.c. |
The courtroom is inaccessible to people with hearing disabilities because there is no assistive listening system provided. |
AA4 |
24 months |
1.12.d. |
The ramp to the jury box is inaccessible because there are no handrails provided. |
R4 |
24 months |
1.12.e. |
The route into the jury box is inaccessible because it is only 27 inches wide. |
AR3 |
24 months |
1.12.f. |
The jury box has fixed seating preventing a juror using a wheelchair from sitting in the jury box and provides insufficient clear floor space. |
AA9 |
24 months |
1.12.g. |
The witness stand is inaccessible because it can be accessed only by steps and provides insufficient clear floor space. |
AA8 |
24 months |
1.12.h. |
The jury room is inaccessible because it can be accessed only by steps. |
AA8 |
24 months |
1.13. |
Second Floor Jury Room Women´s Toilet Room: |
||
1.13.a. |
The toilet room contains a number of inaccessible elements and is not accessible to people with disabilities. |
ST14 |
24 months |
1.13.b. |
Although the facility contains an emergency alarm system, the alarm system is inaccessible because there are no visual alarms provided in toilet room. |
AL1 |
24 months |
1.14. |
Second Floor Jury Room Men´s Toilet Room: |
||
1.14.a. |
The toilet room contains a number of inaccessible elements and is not accessible to people with disabilities. |
ST14 |
24 months |
1.14.b. |
Although the facility contains an emergency alarm system, the alarm system is inaccessible because there are no visual alarms provided in toilet room. |
AL1 |
24 months |
1.15. |
Second Floor Law Enforcement Room: |
||
1.15.a. |
The door is inaccessible because knob hardware is used. |
D1 |
24 months |
1.15.b. |
The door is inaccessible because there is a 6.5 inch high threshold. |
D23 |
24 months |
1.16. |
Second Floor Unisex Single User Toilet Room near Jury Room 2: |
||
1.16.a. |
The toilet room contains a number of inaccessible elements and is not accessible to people with disabilities. |
SU13 |
24 months |
1.16.b. |
Although the facility contains an emergency alarm system, the alarm system is inaccessible because there are no visual alarms provided in toilet room. |
AL1 |
24 months |
1.17. |
Third Floor Public Defender´s Office: |
||
1.17.a. |
The route is inaccessible because it can be accessed only by steps. |
AR2 |
24 months |
1.17.b. |
The fire extinguisher on the wall protrudes into the walkway and is not detectable to blind persons using a cane. |
AR8 |
24 months |
2. |
Mapping Office, located at 204 West Pearl Street, Poplarville |
||
2.1. |
Route from Parking to Accessible Entrance: |
|
|
2.1.a. |
The route to the ramp is inaccessible because the surface is not firm, stable or slip-resistant, and it is not level. |
AR1 |
24 months |
2.1.b. |
The ramp is inaccessible because it has a slope of up to 12.6%, does not have level landings at the top or bottom, and does not have handrails. |
R5 |
24 months |
2.2. |
Rear Accessible Entrance: |
||
2.2.a. |
The building does not have the International Symbol of Accessibility posted at accessible entrances. |
D16 |
24 months |
2.2.b. |
The door is inaccessible because knob hardware is used. |
D1 |
24 months |
2.2.c. |
The designated accessible entrance is inaccessible because it is locked. |
D14, M2 |
24 months |
2.3. |
Interior Door: The door is inaccessible because knob hardware is used. |
D1 |
24 months |
2.4. |
Women´s Single User Toilet Room: |
||
2.4.a. |
The toilet room contains a number of inaccessible elements and is not accessible to people with disabilities. |
SU13 |
24 months |
2.4.b. |
Although the facility contains an emergency alarm system, the alarm system is inaccessible because there are no visual alarms provided in toilet room. |
AL1 |
24 months |
2.5. |
Men´s Single User Toilet Room: |
||
2.5.a. |
The toilet room contains a number of inaccessible elements and is not accessible to people with disabilities. |
SU13 |
24 months |
2.5.b. |
Although the facility contains an emergency alarm system, the alarm system is inaccessible because there are no visual alarms provided in toilet room. |
AL1 |
24 months |
3. |
Yellow Building, located at 206 Julia Street, Poplarville |
||
3.1. |
Route from Front Sidewalk to Entrance: The route is inaccessible because it slopes up to 15.5%. |
AR1 |
18 months |
3.2. |
Main Entrance: |
||
3.2.a. |
The door is inaccessible because there is a slope of 12.5% within the door´s required maneuvering clearance. |
D13 |
18 months |
3.2.b. |
The door is inaccessible because knob hardware is used. |
D1 |
18 months |
3.3. |
Conference Room: |
||
3.3.a. |
The door is inaccessible because knob hardware is used. |
D1 |
18 months |
3.3.b. |
The table is inaccessible because it is 25.5 inches high to the bottom. |
T1 |
18 months |
4. |
County Road Department, located at 8953 Highway 11 South, Poplarville |
||
4.1. |
Parking: The parking lot, with a total of approximately 6 parking spaces, is inaccessible because it has no spaces designated as accessible. This lot requires one (1) van accessible space. |
P3 |
12 months |
4.2. |
Main Entrance: |
||
4.2.a. |
The door is inaccessible because there is a slope of 5.3% within the door´s required maneuvering clearance. |
D13 |
12 months |
4.2.b. |
The pull side of the door, which is accessed through a front approach, is inaccessible because it has no clear space on the latch side. |
D6 |
12 months |
5. |
Mississippi Department of Corrections, located at 313 West Moody Street, Poplarville |
||
5.1. |
Unisex Single User Toilet Room: |
||
5.1.a. |
The toilet room sign is mounted on the door and has no raised or Braille characters. |
TR17 |
12 months |
5.1.b. |
The door is inaccessible because it requires 10 pounds of force to open. |
D2 |
12 months |
5.1.c. |
No accessible mirror has been provided. |
TR14 |
12 months |
5.1.d. |
The toilet is inaccessible because its centerline is 21 inches from the side wall. |
SU15 |
12 months |
5.1.e. |
The side grab bar at the toilet is inaccessible because it is 36 inches long and the farthest end is mounted 41 inches from the rear wall. |
SU6 |
12 months |
5.1.f. |
The rear grab bar at the toilet is inaccessible because it is 24 inches long and the closer end is mounted 9 inches from the side wall. |
SU3 |
12 months |
5.1.g. |
The rear grab bar at the toilet is inaccessible because it is obstructed by the toilet flush pipe. |
SU4 |
12 months |
5.1.h. |
Although the facility contains an emergency alarm system, the alarm system is inaccessible because there are no visual alarms provided in toilet rooms. |
AL1 |
12 months |
5.2. |
Officer Rushing´s Office: |
||
5.2.a. |
The door is inaccessible because knob hardware is used. |
D1 |
12 months |
5.2.b. |
The door is inaccessible because there is a 1.5 inch high threshold. |
D23 |
12 months |
5.3. |
Unisex Single User Toilet Room in Officer Rushing´s Office: |
||
5.3.a. |
The toilet room contains a number of inaccessible elements and is not accessible to people with disabilities. |
SU13 |
12 months |
5.3.b. |
Although the facility contains an emergency alarm system, the alarm system is inaccessible because there are no visual alarms provided in toilet rooms. |
AL1 |
12 months |
5.4. |
Unisex Single User Toilet Room in Officer Spears´ Office: |
||
5.4.a. |
The toilet room contains a number of inaccessible elements and is not accessible to people with disabilities. |
SU13 |
12 months |
5.4.b. |
Although the facility contains an emergency alarm system, the alarm system is inaccessible because there are no visual alarms provided in toilet rooms. |
AL1 |
12 months |
6. |
Mississippi State Extension Office, located at 417 Highway 11 North, Poplarville |
||
6.1. |
County Extension Office: |
||
6.1.a. |
The double doors to the hallway are inaccessible because each leaf is 27.5 inches wide. |
D24 |
12 months |
6.1.b. |
The door to the hallway is inaccessible because it requires 10 pounds of force to open. |
D2 |
12 months |
6.1.c. |
The door to both the hallway and the office are inaccessible because knob hardware is used. |
D1 |
12 months |
6.2. |
4-H Agent Office: |
||
6.2.a. |
The door is inaccessible because it has an opening width of 29.5 inches. |
D25 |
12 months |
6.2.b. |
The door is inaccessible because knob hardware is used. |
D1 |
12 months |
6.3. |
County Agent´s Office: |
||
6.3.a. |
The door is inaccessible because it has an opening width of 29.5 inches. |
D25 |
12 months |
6.3.b. |
The door is inaccessible because knob hardware is used. |
D1 |
12 months |
6.4. |
Men´s Toilet Room near County Extension Office: |
||
6.4.a. |
The toilet room sign is mounted on the door and has no raised or Braille characters. |
TR17 |
12 months |
6.4.b. |
The door is inaccessible because it has an opening width of 29.5 inches. |
D25 |
12 months |
6.4.c. |
The door is inaccessible because it requires 15 pounds of force to open. |
D2 |
12 months |
6.4.d. |
The pull side of the door, which is accessed through a front approach, is inaccessible because it has less than 18 inches of clear space on the latch side. |
D6 |
12 months |
6.4.e. |
No accessible mirror has been provided. |
TR14 |
12 months |
6.4.f. |
The lavatory is inaccessible because the hot water and drain pipes are not insulated or otherwise configured to protect against contact. |
TR12 |
12 months |
6.4.g. |
The urinal is inaccessible because the rim is 18.75 inches high. |
TR20 |
12 months |
6.4.h. |
The designated accessible stall is incorrectly configured as an ambulatory stall, and there is no standard accessible stall provided. |
ST15 |
12 months |
6.5. |
Women´s Toilet Room near County Extension Office: |
||
6.5.a. |
The toilet room sign is mounted on the door and has no raised or Braille characters. |
TR17 |
12 months |
6.5.b. |
The door is inaccessible because it has an opening width of 29.5 inches. |
D25 |
12 months |
6.5.c. |
The door is inaccessible because it requires 15 pounds of force to open. |
D2 |
12 months |
6.5.d. |
The pull side of the door, which is accessed through a front approach, is inaccessible because it has only 4.5 inches of clear space on the latch side. |
D6 |
12 months |
6.5.e. |
No accessible mirror has been provided. |
TR14 |
12 months |
6.5.f. |
The lavatory is inaccessible because the hot water and drain pipes are not insulated or otherwise configured to protect against contact. |
TR12 |
12 months |
6.5.g. |
The designated accessible stall is incorrectly configured as an ambulatory stall, and there is no standard accessible stall provided. |
ST15 |
12 months |
6.6. |
Drinking Fountain near County Extension Office: |
||
6.6.a. |
The drinking fountain is inaccessible because it does not provide sufficient clear floor space. |
DF5 |
12 months |
6.6.b. |
The route past the drinking fountain is inaccessible because it is only 28.5 inches wide. |
AR3 |
12 months |
6.7. |
Department of Human Services Office: |
||
6.7.a. |
The door is inaccessible because knob hardware is used. |
D1 |
12 months |
6.7.b. |
The door is inaccessible because it requires 9 pounds of force to open. |
D2 |
12 months |
6.8. |
Typical Office in Building: |
||
6.8.a. |
The door is inaccessible because it has an opening width of 29 inches. |
D25 |
12 months |
6.8.b. |
The door is inaccessible because knob hardware is used. |
D1 |
12 months |
6.9. |
Women´s Toilet Room near Youth Court Services: |
||
6.9.a. |
The toilet room sign is mounted on the door and has no raised or Braille characters. |
TR17 |
12 months |
6.9.b. |
The vestibule doors are inaccessible because they both have an opening width of 29 inches. |
D25 |
12 months |
6.9.c. |
The vestibule doors are inaccessible because the outer vestibule door requires 15 pounds of force to open, and the inner vestibule door requires 16 pounds of force to open. |
D2 |
12 months |
6.9.d. |
The pull side of the outer vestibule door, which is accessed through a front approach, is inaccessible because it has only 4 inches of clear space on the latch side. |
D6 |
12 months |
6.9.e. |
The door outer vestibule is inaccessible because the vestibule is not sufficiently deep. |
D3 |
12 months |
6.9.f. |
No accessible mirror has been provided. |
TR14 |
12 months |
6.9.g. |
The lavatory is inaccessible because it has twist-type hardware. |
TR10 |
12 months |
6.9.h. |
The designated accessible stall is incorrectly configured as an ambulatory stall, and there is no standard accessible stall provided. |
ST15 |
12 months |
6.10. |
Men´s Toilet Room near Youth Court Services: |
||
6.10.a. |
The toilet room sign is mounted on the door and has no raised or Braille characters. |
TR18 |
12 months |
6.10.b. |
The vestibule doors are inaccessible because they both have an opening width of 29 inches. |
D25 |
12 months |
6.10.c. |
The vestibule doors are inaccessible because they both require 15 pounds of force to open. |
D2 |
12 months |
6.10.d. |
The pull side of the outer vestibule door, which is accessed through a front approach, is inaccessible because it has only 4.25 inches of clear space on the latch side. |
D6 |
12 months |
6.10.e. |
The outer vestibule door is inaccessible because the vestibule is not sufficiently deep. |
D3 |
12 months |
6.10.f. |
No accessible mirror has been provided. |
TR14 |
12 months |
6.10.g. |
The lavatory is inaccessible because it has twist-type hardware. |
TR10 |
12 months |
6.10.h. |
The urinal is inaccessible because the rim is 19 inches high. |
TR20 |
12 months |
6.10.i. |
The designated accessible stall is incorrectly configured as an ambulatory stall, and there is no standard accessible stall provided. |
ST15 |
12 months |
6.11. |
Drinking Fountain near Youth Court Services: The drinking fountain is inaccessible because it has a spout that is 37 inches high. |
DF6 |
12 months |
7. |
Pearl River County Court Facilities, located at 204 Julia Street, Poplarville |
||
7.1.a. |
Parking: |
||
7.1.b. |
The parking lot is inaccessible because there is no designated van accessible space and the pavement markings are not clear. This lot requires one (1) van accessible space. |
P3 |
12 months |
7.1.c. |
Left Space: |
||
7.1.c.1) |
The designated accessible parking is inaccessible because it lacks vertical signage. |
P6 |
12 months |
7.1.c.2) |
The designated accessible parking is inaccessible because the space slopes 3.7% and the access aisle slopes 4.4%. |
P7 |
12 months |
7.1.d. |
Right Space: |
||
7.1.d.1) |
The designated accessible parking is inaccessible because it slopes 4.4%. |
P7 |
12 months |
7.1.d.2) |
The designated accessible parking is inaccessible because it lacks vertical signage. |
P6 |
12 months |
7.2. |
Ramp to the Main Entrance: |
||
7.2.a. |
The ramp is inaccessible because the ends of the handrails are not rounded or returned, do not have a gripping surface of 1.25-1.5 inches in diameter, and are not smooth and free of splinters. |
R4 |
12 months |
7.2.b. |
The ramp is inaccessible because it does not have edge protection at the drop off sides. |
R1 |
12 months |
7.3. |
Information Desk: |
||
7.3.a. |
The counter is inaccessible because it is 41 inches high. |
C6 |
12 months |
7.3.b. |
The counter protrudes into the walkway and is not detectable to blind persons using a cane. |
AR8 |
12 months |
7.4. |
Courtroom: |
||
7.4.a. |
The double doors are inaccessible because each leaf is 27.75 inches wide. |
D24 |
12 months |
7.4.b. |
The judge´s bench is inaccessible because it can be accessed only by steps. |
AA8 |
12 months |
7.4.c. |
The signage provided is inaccessible because it does not have raised and Braille characters. |
D26 |
12 months |
7.4.d. |
The courtroom is inaccessible to people with hearing disabilities because there is no assistive listening system provided. |
AA5 |
12 months |
7.5. |
Men´s Single User Toilet Room right of the Main Entrance: |
||
7.5.a. |
The toilet room sign is mounted on the door and has no raised or Braille characters. |
TR17 |
12 months |
7.5.b. |
The door is inaccessible because it requires 7 pounds of force to open. |
D2 |
12 months |
7.5.c. |
The door is inaccessible because knob hardware is used. |
D1 |
12 months |
7.5.d. |
No accessible mirror has been provided. |
TR14 |
12 months |
7.5.e. |
The lavatory is inaccessible because the bottom of the apron is 27.5 inches high. |
TR11 |
12 months |
7.5.f. |
The toilet is inaccessible because there are no grab bars provided. |
SU10 |
12 months |
7.6. |
Women´s Single User Toilet Room right of the Main Entrance: |
||
7.6.a. |
The toilet room sign is mounted on the door and has no raised or Braille characters. |
TR17 |
12 months |
7.6.b. |
The door is inaccessible because it requires 7 pounds of force to open. |
D2 |
12 months |
7.6.c. |
The door is inaccessible because knob hardware is used. |
D1 |
12 months |
7.6.d. |
No accessible mirror has been provided. |
TR14 |
12 months |
7.6.e. |
The lavatory is inaccessible because the bottom of the apron is 27.5 inches high. |
TR11 |
12 months |
7.6.f. |
The toilet is inaccessible because there are no grab bars provided. |
SU10 |
12 months |
7.7. |
Drinking Fountain near Single User Toilet Rooms right of the Main Entrance: Although a designated accessible drinking fountain is provided, there is no drinking fountain provided for people who have difficulty bending or stooping. |
DF3 |
12 months |
7.8. |
Women´s Single User Toilet Room left of the Main Entrance: |
||
7.8.a. |
The toilet room sign is mounted on the door and has no raised or Braille characters. |
TR17 |
12 months |
7.8.b. |
The door is inaccessible because it requires 9 pounds of force to open. |
D2 |
12 months |
7.8.c. |
The pull side of the door, which is accessed through a front approach, is inaccessible because it has only 10 inches of clear space on the latch side. |
D6 |
12 months |
7.8.d. |
No accessible mirror has been provided. |
TR14 |
12 months |
7.8.e. |
The lavatory is inaccessible because the bottom of the apron is 28.25 inches high. |
TR11 |
12 months |
7.8.f. |
The toilet is inaccessible because its centerline is 20 inches from the side wall. |
SU15 |
12 months |
7.8.g. |
The toilet is inaccessible because the flush control is on the closed side. |
SU1 |
12 months |
7.8.h. |
The side grab bar at the toilet is inaccessible because it is 30 inches long and the farther end is mounted 32.5 inches from the rear wall. |
SU6 |
12 months |
7.8.i. |
The toilet is inaccessible because there is no rear grab bar provided. |
SU2 |
12 months |
7.9. |
Men´s Single User Toilet Room left of the Main Entrance: |
||
7.9.a. |
The toilet room sign is mounted on the door and has no raised or Braille characters. |
TR17 |
12 months |
7.9.b. |
The door is inaccessible because it requires 9 pounds of force to open. |
D2 |
12 months |
7.9.c. |
The pull side of the door, which is accessed through a front approach, is inaccessible because it has only 8 inches of clear space on the latch side. |
D6 |
12 months |
7.9.d. |
No accessible mirror has been provided. |
TR14 |
12 months |
7.9.e. |
The lavatory is inaccessible because the bottom of the apron is 28 inches high. |
TR11 |
12 months |
7.9.f. |
The toilet is inaccessible because its centerline is 20 inches from the side wall. |
SU15 |
12 months |
7.9.g. |
The side grab bar at the toilet is inaccessible because the farther end is mounted 52 inches from the rear wall. |
SU6 |
12 months |
7.9.h. |
The toilet is inaccessible because there is no rear grab bar provided. |
SU2 |
12 months |
7.10. |
Metal Detector: The route through the metal detector is inaccessible because it is only 30.25 inches wide. |
AR3, M2 |
12 months |
7.11. |
Chancery Court: |
||
7.11.a. |
The double doors are inaccessible because each leaf is 27.75 inches wide. |
D24 |
12 months |
7.11.b. |
The judge´s bench is inaccessible because it can be accessed only by steps. |
AA8 |
12 months |
7.11.c. |
The courtroom is inaccessible to people with hearing disabilities because there is no assistive listening system provided. This courtroom requires two receivers. |
AA5 |
12 months |
7.12. |
Attorney´s Conference Room: |
||
7.12.a. |
The door to the courtroom is inaccessible because it has an opening width of only 30 inches. |
D25 |
12 months |
7.12.b. |
The door to the courtroom is inaccessible because knob hardware is used. |
D1 |
12 months |
8. |
Pearl River County Fairgrounds |
||
8.1. |
Parking: The parking lot is inaccessible because there are no designated accessible spaces and it is not stable, firm, and slip-resistant. |
P3 |
12 months |
8.2. |
Food Counter: The counter is inaccessible because it is 39.5 inches high. |
C5 |
12 months |
8.3. |
Outdoor Men´s and Women´s Toilet Rooms: |
||
8.3.a. |
The route from the sidewalk to the toilet rooms is inaccessible because there is a 12.2% slope. |
AR1 |
12 months |
8.3.b. |
The men´s and women´s toilet rooms contain a number of inaccessible elements and are not accessible to people with disabilities. |
TR22 |
12 months |
8.3.c. |
There is no accessible shower provided in either toilet room. |
B8 |
12 months |
8.4. |
Rodeo Arena: (new or altered) |
||
8.4.a. |
The route to the arena seating is inaccessible because it is not firm, stable, and slip-resistant. |
AR1 |
12 months |
8.4.b. |
The chain link door to enter the arena seating is inaccessible because there is a slope of 10.3% within the door´s required maneuvering clearance. |
D13 |
12 months |
8.4.c. |
The rodeo area, containing 1,200 seats, is inaccessible because only 7 wheelchair seating areas are provided (each wheelchair seating cutout is not wide enough for two wheelchairs), the wheelchair seating areas are only 27 inches deep, the fixed companion seating does not line up next to the wheelchair seating, and the lines of sight from the wheelchair seating are not comparable to the rest of the seating (in part because of the obstructed view through the chainlink fence). A total of 13 wheelchair seating areas are required. |
AA7 |
12 months |
8.5. |
Ramp to Rodeo Area: The ramp is inaccessible because it has a slope of up to 8.7%. |
R3 |
12 months |
8.6. |
Smaller Show Arena: |
||
8.6.a. |
The route to the smaller show arena and live stock display area is inaccessible because the surface is not stable, firm, and slip-resistant. |
AR1 |
12 months |
8.6.b. |
The smaller show arena is inaccessible because no wheelchair seating areas are provided. |
AA6 |
12 months |
8.7. |
Exhibit Hall: |
||
8.7.a. |
The door is inaccessible because there is a 1.25 inch high threshold. |
D23 |
12 months |
8.7.b. |
The men´s and women´s toilet rooms contain a number of inaccessible elements and are not accessible to people with disabilities. |
TR22 |
12 months |
8.8. |
Mary Hough Building: The route is inaccessible because it has a slope of 11.3%. |
AR1 |
12 months |