ATTACHMENT K: Program Access in Existing Facilities

Please Note: Paragraph 55 of the Agreement requires that within three months of the effective date of this Agreement, the County will provide signage as necessary to comply with 28 C.F.R. § 35.163(b), after having surveyed all facilities that are the subject of this Agreement for the purpose of identifying those that have multiple entrances not all of which are accessible.

The technical requirements and, where appropriate, the scoping requirements of the Standards are used as a guide for determining whether a program or activity held in an existing facility is " readily accessible to and usable by" persons with disabilities and for determining what changes are necessary to make this program or activity accessible if it continues to be provided in the existing facility in question. See 28 C.F.R. §§ 35.150(b)(1), 35.151.

The chart below lists the facilities surveyed by the Department, the access issues identified during the survey, and the actions required to correct the access issues. Required actions are listed using an alphanumeric code. The key to the alphanumeric codes is provided in Attachment M to this Agreement.

In order to ensure that the programs, services, and activities housed in the County´s facilities are accessible to persons with disabilities, when viewed in their entirety, the County will take the actions referenced by the alphanumeric code and described in detail in Attachment M to this Settlement Agreement within the time period specified below, which time period begins to run on the effective date of the Agreement.

Item #

Access Issue

Required Action

Completion Date

1.

Courthouse, located at 200 South Main Street, Poplarville

   

1.1.

Parking:

   

1.1.a.

The parking lot, with a total of approximately 25 parking spaces, is inaccessible because there is no designated van accessible space, and the pavement markings for the accessible spaces are not clear. This lot requires one (1) van accessible space.

P3

24 months

1.1.b.

Far Right Space:

   

1.1.b.1)

The designated accessible parking is inaccessible because the sign is mounted too low and does not indicate the space is van accessible.

P6

24 months

1.1.b.2)

The designated accessible parking is inaccessible because there is no access aisle.

P1

24 months

1.1.c.

Center Space:

   

1.1.c.1)

The designated accessible parking is inaccessible because the sign is mounted too low.

P6

24 months

1.1.c.2)

The designated accessible parking is inaccessible because it slopes 2.6%.

P7

24 months

1.1.d.

Far Left Space:

   

1.1.d.1)

The designated accessible parking is inaccessible because it lacks vertical signage.

P6

24 months

1.1.d.2)

The designated accessible parking is inaccessible because it slopes 2.8% and has a cross slope of 2.8%.

P7

24 months

1.2.

Route from Parking to Sidewalk: The built-up curb ramp is inaccessible because it has a slope of 17.1%, a rise of 7 inches, lacks flared sides, and impermissibly extends into the required parking space´s access aisle.

AR4, AR5

24 months

1.3.

Ramp to East Entrance: The ramp is inaccessible because the handrails are mounted 33 inches above the ramp surface and do not extend at least 12 inches beyond the top and bottom of the ramp parallel with the ground surface.

R4

24 months

1.4.

Entrances:

   

1.4.a.

The building is inaccessible because fewer than 50% of its entrances are accessible.

D12

24 months

1.4.b.

The building does not have directional signage posted at inaccessible entrances and does not have the International Symbol of Accessibility posted at accessible entrances.

D16

24 months

1.5.

Central Elevators:

   

1.5.a.

The elevator is inaccessible because the hall lanterns do not emit an audible signal indicating when a car is answering a call.

E11

24 months

1.5.b.

The elevator is inaccessible because the doors of the car do not open and close automatically.

E6

24 months

1.5.c.

The elevator is inaccessible because the emergency controls are not grouped at the bottom of the panel.

E9

24 months

1.6.

Sheriff´s Office:

   

1.6.a.

The door is inaccessible because it requires 9 pounds of force to open.

D2

24 months

1.6.b.

The door is inaccessible because knob hardware is used.

D1

24 months

1.6.c.

The push side of the door, which is accessed through a front approach and which has both a closer and a latch, is inaccessible because it has no clear space on the latch side.

D7

24 months

1.7.

Chancery Clerk´s Office:

   

1.7.a.

The two doors are inaccessible because knob hardware is used.

D1

24 months

1.7.b.

The push side of each door, which is accessed through a front approach and which has both a closer and a latch, is inaccessible because it has no clear space on the latch side.

D7

24 months

1.8.

First Floor Men´s Toilet Room:

   

1.8.a.

The toilet room sign is mounted on the door and has no raised or Braille characters.

TR17

24 months

1.8.b.

The urinal is inaccessible because the rim is not 17 inches or less above the finished floor and the flush control is 52 inches above the finished floor.

TR20

24 months

1.8.c.

The designated accessible toilet is inaccessible because its centerline is 16 inches from the side wall.

ST17

24 months

1.8.d.

The designated accessible toilet is inaccessible because the flush control is on the closed side.

ST2

24 months

1.8.e.

The toilet paper dispenser in the designated accessible stall is inaccessible because it is mounted 42 inches from the rear wall.

ST19

24 months

1.8.f.

No accessible coat hook has been provided.

TR1

24 months

1.8.g.

The designated accessible toilet stall is inaccessible because it is not at least 60 inches wide and at least 56 inches deep.

ST16

24 months

1.8.h.

The soap dispenser is inaccessible because it is mounted 52 inches high.

TR4

24 months

1.9.

First Floor Women´s Toilet Room:

   

1.9.a.

The toilet room sign is mounted on the door and has no raised or Braille characters.

TR17

24 months

1.9.b.

The designated accessible toilet is inaccessible because its centerline is 14 inches from the side wall.

ST17

24 months

1.9.c.

No accessible coat hook has been provided.

TR1

24 months

1.10.

Second Floor Unisex Single User Toilet Room:

   

1.10.a.

The toilet room contains a number of inaccessible elements and is not accessible to people with disabilities.

SU13

24 months

1.10.b.

No accessible coat hook has been provided.

TR1

24 months

1.10.c.

Although the facility contains an emergency alarm system, the alarm system is inaccessible because there are no visual alarms provided in toilet room.

AL1

24 months

1.11.

Second Floor Route to Courtroom: The route to the courtroom is inaccessible because it is only 30.5 inches wide when passing through the metal detector.

AR3, M2

24 months

1.12.

Second Floor Courtroom:

   

1.12.a.

The door is inaccessible because knob hardware is used.

D1

24 months

1.12.b.

The courtroom, containing 163 seats, is inaccessible because only 1 wheelchair seating area is provided. A total of 4 wheelchair seating areas are required.

AA6

24 months

1.12.c.

The courtroom is inaccessible to people with hearing disabilities because there is no assistive listening system provided.

AA4

24 months

1.12.d.

The ramp to the jury box is inaccessible because there are no handrails provided.

R4

24 months

1.12.e.

The route into the jury box is inaccessible because it is only 27 inches wide.

AR3

24 months

1.12.f.

The jury box has fixed seating preventing a juror using a wheelchair from sitting in the jury box and provides insufficient clear floor space.

AA9

24 months

1.12.g.

The witness stand is inaccessible because it can be accessed only by steps and provides insufficient clear floor space.

AA8

24 months

1.12.h.

The jury room is inaccessible because it can be accessed only by steps.

AA8

24 months

1.13.

Second Floor Jury Room Women´s Toilet Room:

   

1.13.a.

The toilet room contains a number of inaccessible elements and is not accessible to people with disabilities.

ST14

24 months

1.13.b.

Although the facility contains an emergency alarm system, the alarm system is inaccessible because there are no visual alarms provided in toilet room.

AL1

24 months

1.14.

Second Floor Jury Room Men´s Toilet Room:

   

1.14.a.

The toilet room contains a number of inaccessible elements and is not accessible to people with disabilities.

ST14

24 months

1.14.b.

Although the facility contains an emergency alarm system, the alarm system is inaccessible because there are no visual alarms provided in toilet room.

AL1

24 months

1.15.

Second Floor Law Enforcement Room:

   

1.15.a.

The door is inaccessible because knob hardware is used.

D1

24 months

1.15.b.

The door is inaccessible because there is a 6.5 inch high threshold.

D23

24 months

1.16.

Second Floor Unisex Single User Toilet Room near Jury Room 2:

   

1.16.a.

The toilet room contains a number of inaccessible elements and is not accessible to people with disabilities.

SU13

24 months

1.16.b.

Although the facility contains an emergency alarm system, the alarm system is inaccessible because there are no visual alarms provided in toilet room.

AL1

24 months

1.17.

Third Floor Public Defender´s Office:

   

1.17.a.

The route is inaccessible because it can be accessed only by steps.

AR2

24 months

1.17.b.

The fire extinguisher on the wall protrudes into the walkway and is not detectable to blind persons using a cane.

AR8

24 months

2.

Mapping Office, located at 204 West Pearl Street, Poplarville

   

2.1.

Route from Parking to Accessible Entrance:

 

2.1.a.

The route to the ramp is inaccessible because the surface is not firm, stable or slip-resistant, and it is not level.

AR1

24 months

2.1.b.

The ramp is inaccessible because it has a slope of up to 12.6%, does not have level landings at the top or bottom, and does not have handrails.

R5

24 months

2.2.

Rear Accessible Entrance:

   

2.2.a.

The building does not have the International Symbol of Accessibility posted at accessible entrances.

D16

24 months

2.2.b.

The door is inaccessible because knob hardware is used.

D1

24 months

2.2.c.

The designated accessible entrance is inaccessible because it is locked.

D14, M2

24 months

2.3.

Interior Door: The door is inaccessible because knob hardware is used.

D1

24 months

2.4.

Women´s Single User Toilet Room:

   

2.4.a.

The toilet room contains a number of inaccessible elements and is not accessible to people with disabilities.

SU13

24 months

2.4.b.

Although the facility contains an emergency alarm system, the alarm system is inaccessible because there are no visual alarms provided in toilet room.

AL1

24 months

2.5.

Men´s Single User Toilet Room:

   

2.5.a.

The toilet room contains a number of inaccessible elements and is not accessible to people with disabilities.

SU13

24 months

2.5.b.

Although the facility contains an emergency alarm system, the alarm system is inaccessible because there are no visual alarms provided in toilet room.

AL1

24 months

3.

Yellow Building, located at 206 Julia Street, Poplarville

   

3.1.

Route from Front Sidewalk to Entrance: The route is inaccessible because it slopes up to 15.5%.

AR1

18 months

3.2.

Main Entrance:

   

3.2.a.

The door is inaccessible because there is a slope of 12.5% within the door´s required maneuvering clearance.

D13

18 months

3.2.b.

The door is inaccessible because knob hardware is used.

D1

18 months

3.3.

Conference Room:

   

3.3.a.

The door is inaccessible because knob hardware is used.

D1

18 months

3.3.b.

The table is inaccessible because it is 25.5 inches high to the bottom.

T1

18 months

4.

County Road Department, located at 8953 Highway 11 South, Poplarville

   

4.1.

Parking: The parking lot, with a total of approximately 6 parking spaces, is inaccessible because it has no spaces designated as accessible. This lot requires one (1) van accessible space.

P3

12 months

4.2.

Main Entrance:

   

4.2.a.

The door is inaccessible because there is a slope of 5.3% within the door´s required maneuvering clearance.

D13

12 months

4.2.b.

The pull side of the door, which is accessed through a front approach, is inaccessible because it has no clear space on the latch side.

D6

12 months

5.

Mississippi Department of Corrections, located at 313 West Moody Street, Poplarville

   

5.1.

Unisex Single User Toilet Room:

   

5.1.a.

The toilet room sign is mounted on the door and has no raised or Braille characters.

TR17

12 months

5.1.b.

The door is inaccessible because it requires 10 pounds of force to open.

D2

12 months

5.1.c.

No accessible mirror has been provided.

TR14

12 months

5.1.d.

The toilet is inaccessible because its centerline is 21 inches from the side wall.

SU15

12 months

5.1.e.

The side grab bar at the toilet is inaccessible because it is 36 inches long and the farthest end is mounted 41 inches from the rear wall.

SU6

12 months

5.1.f.

The rear grab bar at the toilet is inaccessible because it is 24 inches long and the closer end is mounted 9 inches from the side wall.

SU3

12 months

5.1.g.

The rear grab bar at the toilet is inaccessible because it is obstructed by the toilet flush pipe.

SU4

12 months

5.1.h.

Although the facility contains an emergency alarm system, the alarm system is inaccessible because there are no visual alarms provided in toilet rooms.

AL1

12 months

5.2.

Officer Rushing´s Office:

   

5.2.a.

The door is inaccessible because knob hardware is used.

D1

12 months

5.2.b.

The door is inaccessible because there is a 1.5 inch high threshold.

D23

12 months

5.3.

Unisex Single User Toilet Room in Officer Rushing´s Office:

   

5.3.a.

The toilet room contains a number of inaccessible elements and is not accessible to people with disabilities.

SU13

12 months

5.3.b.

Although the facility contains an emergency alarm system, the alarm system is inaccessible because there are no visual alarms provided in toilet rooms.

AL1

12 months

5.4.

Unisex Single User Toilet Room in Officer Spears´ Office:

   

5.4.a.

The toilet room contains a number of inaccessible elements and is not accessible to people with disabilities.

SU13

12 months

5.4.b.

Although the facility contains an emergency alarm system, the alarm system is inaccessible because there are no visual alarms provided in toilet rooms.

AL1

12 months

6.

Mississippi State Extension Office, located at 417 Highway 11 North, Poplarville

   

6.1.

County Extension Office:

   

6.1.a.

The double doors to the hallway are inaccessible because each leaf is 27.5 inches wide.

D24

12 months

6.1.b.

The door to the hallway is inaccessible because it requires 10 pounds of force to open.

D2

12 months

6.1.c.

The door to both the hallway and the office are inaccessible because knob hardware is used.

D1

12 months

6.2.

4-H Agent Office:

   

6.2.a.

The door is inaccessible because it has an opening width of 29.5 inches.

D25

12 months

6.2.b.

The door is inaccessible because knob hardware is used.

D1

12 months

6.3.

County Agent´s Office:

   

6.3.a.

The door is inaccessible because it has an opening width of 29.5 inches.

D25

12 months

6.3.b.

The door is inaccessible because knob hardware is used.

D1

12 months

6.4.

Men´s Toilet Room near County Extension Office:

   

6.4.a.

The toilet room sign is mounted on the door and has no raised or Braille characters.

TR17

12 months

6.4.b.

The door is inaccessible because it has an opening width of 29.5 inches.

D25

12 months

6.4.c.

The door is inaccessible because it requires 15 pounds of force to open.

D2

12 months

6.4.d.

The pull side of the door, which is accessed through a front approach, is inaccessible because it has less than 18 inches of clear space on the latch side.

D6

12 months

6.4.e.

No accessible mirror has been provided.

TR14

12 months

6.4.f.

The lavatory is inaccessible because the hot water and drain pipes are not insulated or otherwise configured to protect against contact.

TR12

12 months

6.4.g.

The urinal is inaccessible because the rim is 18.75 inches high.

TR20

12 months

6.4.h.

The designated accessible stall is incorrectly configured as an ambulatory stall, and there is no standard accessible stall provided.

ST15

12 months

6.5.

Women´s Toilet Room near County Extension Office:

   

6.5.a.

The toilet room sign is mounted on the door and has no raised or Braille characters.

TR17

12 months

6.5.b.

The door is inaccessible because it has an opening width of 29.5 inches.

D25

12 months

6.5.c.

The door is inaccessible because it requires 15 pounds of force to open.

D2

12 months

6.5.d.

The pull side of the door, which is accessed through a front approach, is inaccessible because it has only 4.5 inches of clear space on the latch side.

D6

12 months

6.5.e.

No accessible mirror has been provided.

TR14

12 months

6.5.f.

The lavatory is inaccessible because the hot water and drain pipes are not insulated or otherwise configured to protect against contact.

TR12

12 months

6.5.g.

The designated accessible stall is incorrectly configured as an ambulatory stall, and there is no standard accessible stall provided.

ST15

12 months

6.6.

Drinking Fountain near County Extension Office:

   

6.6.a.

The drinking fountain is inaccessible because it does not provide sufficient clear floor space.

DF5

12 months

6.6.b.

The route past the drinking fountain is inaccessible because it is only 28.5 inches wide.

AR3

12 months

6.7.

Department of Human Services Office:

   

6.7.a.

The door is inaccessible because knob hardware is used.

D1

12 months

6.7.b.

The door is inaccessible because it requires 9 pounds of force to open.

D2

12 months

6.8.

Typical Office in Building:

   

6.8.a.

The door is inaccessible because it has an opening width of 29 inches.

D25

12 months

6.8.b.

The door is inaccessible because knob hardware is used.

D1

12 months

6.9.

Women´s Toilet Room near Youth Court Services:

   

6.9.a.

The toilet room sign is mounted on the door and has no raised or Braille characters.

TR17

12 months

6.9.b.

The vestibule doors are inaccessible because they both have an opening width of 29 inches.

D25

12 months

6.9.c.

The vestibule doors are inaccessible because the outer vestibule door requires 15 pounds of force to open, and the inner vestibule door requires 16 pounds of force to open.

D2

12 months

6.9.d.

The pull side of the outer vestibule door, which is accessed through a front approach, is inaccessible because it has only 4 inches of clear space on the latch side.

D6

12 months

6.9.e.

The door outer vestibule is inaccessible because the vestibule is not sufficiently deep.

D3

12 months

6.9.f.

No accessible mirror has been provided.

TR14

12 months

6.9.g.

The lavatory is inaccessible because it has twist-type hardware.

TR10

12 months

6.9.h.

The designated accessible stall is incorrectly configured as an ambulatory stall, and there is no standard accessible stall provided.

ST15

12 months

6.10.

Men´s Toilet Room near Youth Court Services:

   

6.10.a.

The toilet room sign is mounted on the door and has no raised or Braille characters.

TR18

12 months

6.10.b.

The vestibule doors are inaccessible because they both have an opening width of 29 inches.

D25

12 months

6.10.c.

The vestibule doors are inaccessible because they both require 15 pounds of force to open.

D2

12 months

6.10.d.

The pull side of the outer vestibule door, which is accessed through a front approach, is inaccessible because it has only 4.25 inches of clear space on the latch side.

D6

12 months

6.10.e.

The outer vestibule door is inaccessible because the vestibule is not sufficiently deep.

D3

12 months

6.10.f.

No accessible mirror has been provided.

TR14

12 months

6.10.g.

The lavatory is inaccessible because it has twist-type hardware.

TR10

12 months

6.10.h.

The urinal is inaccessible because the rim is 19 inches high.

TR20

12 months

6.10.i.

The designated accessible stall is incorrectly configured as an ambulatory stall, and there is no standard accessible stall provided.

ST15

12 months

6.11.

Drinking Fountain near Youth Court Services: The drinking fountain is inaccessible because it has a spout that is 37 inches high.

DF6

12 months

7.

Pearl River County Court Facilities, located at 204 Julia Street, Poplarville

   

7.1.a.

Parking:

   

7.1.b.

The parking lot is inaccessible because there is no designated van accessible space and the pavement markings are not clear. This lot requires one (1) van accessible space.

P3

12 months

7.1.c.

Left Space:

   

7.1.c.1)

The designated accessible parking is inaccessible because it lacks vertical signage.

P6

12 months

7.1.c.2)

The designated accessible parking is inaccessible because the space slopes 3.7% and the access aisle slopes 4.4%.

P7

12 months

7.1.d.

Right Space:

   

7.1.d.1)

The designated accessible parking is inaccessible because it slopes 4.4%.

P7

12 months

7.1.d.2)

The designated accessible parking is inaccessible because it lacks vertical signage.

P6

12 months

7.2.

Ramp to the Main Entrance:

   

7.2.a.

The ramp is inaccessible because the ends of the handrails are not rounded or returned, do not have a gripping surface of 1.25-1.5 inches in diameter, and are not smooth and free of splinters.

R4

12 months

7.2.b.

The ramp is inaccessible because it does not have edge protection at the drop off sides.

R1

12 months

7.3.

Information Desk:

   

7.3.a.

The counter is inaccessible because it is 41 inches high.

C6

12 months

7.3.b.

The counter protrudes into the walkway and is not detectable to blind persons using a cane.

AR8

12 months

7.4.

Courtroom:

   

7.4.a.

The double doors are inaccessible because each leaf is 27.75 inches wide.

D24

12 months

7.4.b.

The judge´s bench is inaccessible because it can be accessed only by steps.

AA8

12 months

7.4.c.

The signage provided is inaccessible because it does not have raised and Braille characters.

D26

12 months

7.4.d.

The courtroom is inaccessible to people with hearing disabilities because there is no assistive listening system provided.

AA5

12 months

7.5.

Men´s Single User Toilet Room right of the Main Entrance:

   

7.5.a.

The toilet room sign is mounted on the door and has no raised or Braille characters.

TR17

12 months

7.5.b.

The door is inaccessible because it requires 7 pounds of force to open.

D2

12 months

7.5.c.

The door is inaccessible because knob hardware is used.

D1

12 months

7.5.d.

No accessible mirror has been provided.

TR14

12 months

7.5.e.

The lavatory is inaccessible because the bottom of the apron is 27.5 inches high.

TR11

12 months

7.5.f.

The toilet is inaccessible because there are no grab bars provided.

SU10

12 months

7.6.

Women´s Single User Toilet Room right of the Main Entrance:

   

7.6.a.

The toilet room sign is mounted on the door and has no raised or Braille characters.

TR17

12 months

7.6.b.

The door is inaccessible because it requires 7 pounds of force to open.

D2

12 months

7.6.c.

The door is inaccessible because knob hardware is used.

D1

12 months

7.6.d.

No accessible mirror has been provided.

TR14

12 months

7.6.e.

The lavatory is inaccessible because the bottom of the apron is 27.5 inches high.

TR11

12 months

7.6.f.

The toilet is inaccessible because there are no grab bars provided.

SU10

12 months

7.7.

Drinking Fountain near Single User Toilet Rooms right of the Main Entrance: Although a designated accessible drinking fountain is provided, there is no drinking fountain provided for people who have difficulty bending or stooping.

DF3

12 months

7.8.

Women´s Single User Toilet Room left of the Main Entrance:

   

7.8.a.

The toilet room sign is mounted on the door and has no raised or Braille characters.

TR17

12 months

7.8.b.

The door is inaccessible because it requires 9 pounds of force to open.

D2

12 months

7.8.c.

The pull side of the door, which is accessed through a front approach, is inaccessible because it has only 10 inches of clear space on the latch side.

D6

12 months

7.8.d.

No accessible mirror has been provided.

TR14

12 months

7.8.e.

The lavatory is inaccessible because the bottom of the apron is 28.25 inches high.

TR11

12 months

7.8.f.

The toilet is inaccessible because its centerline is 20 inches from the side wall.

SU15

12 months

7.8.g.

The toilet is inaccessible because the flush control is on the closed side.

SU1

12 months

7.8.h.

The side grab bar at the toilet is inaccessible because it is 30 inches long and the farther end is mounted 32.5 inches from the rear wall.

SU6

12 months

7.8.i.

The toilet is inaccessible because there is no rear grab bar provided.

SU2

12 months

7.9.

Men´s Single User Toilet Room left of the Main Entrance:

   

7.9.a.

The toilet room sign is mounted on the door and has no raised or Braille characters.

TR17

12 months

7.9.b.

The door is inaccessible because it requires 9 pounds of force to open.

D2

12 months

7.9.c.

The pull side of the door, which is accessed through a front approach, is inaccessible because it has only 8 inches of clear space on the latch side.

D6

12 months

7.9.d.

No accessible mirror has been provided.

TR14

12 months

7.9.e.

The lavatory is inaccessible because the bottom of the apron is 28 inches high.

TR11

12 months

7.9.f.

The toilet is inaccessible because its centerline is 20 inches from the side wall.

SU15

12 months

7.9.g.

The side grab bar at the toilet is inaccessible because the farther end is mounted 52 inches from the rear wall.

SU6

12 months

7.9.h.

The toilet is inaccessible because there is no rear grab bar provided.

SU2

12 months

7.10.

Metal Detector: The route through the metal detector is inaccessible because it is only 30.25 inches wide.

AR3, M2

12 months

7.11.

Chancery Court:

   

7.11.a.

The double doors are inaccessible because each leaf is 27.75 inches wide.

D24

12 months

7.11.b.

The judge´s bench is inaccessible because it can be accessed only by steps.

AA8

12 months

7.11.c.

The courtroom is inaccessible to people with hearing disabilities because there is no assistive listening system provided. This courtroom requires two receivers.

AA5

12 months

7.12.

Attorney´s Conference Room:

   

7.12.a.

The door to the courtroom is inaccessible because it has an opening width of only 30 inches.

D25

12 months

7.12.b.

The door to the courtroom is inaccessible because knob hardware is used.

D1

12 months

8.

Pearl River County Fairgrounds

   

8.1.

Parking: The parking lot is inaccessible because there are no designated accessible spaces and it is not stable, firm, and slip-resistant.

P3

12 months

8.2.

Food Counter: The counter is inaccessible because it is 39.5 inches high.

C5

12 months

8.3.

Outdoor Men´s and Women´s Toilet Rooms:

   

8.3.a.

The route from the sidewalk to the toilet rooms is inaccessible because there is a 12.2% slope.

AR1

12 months

8.3.b.

The men´s and women´s toilet rooms contain a number of inaccessible elements and are not accessible to people with disabilities.

TR22

12 months

8.3.c.

There is no accessible shower provided in either toilet room.

B8

12 months

8.4.

Rodeo Arena: (new or altered)

   

8.4.a.

The route to the arena seating is inaccessible because it is not firm, stable, and slip-resistant.

AR1

12 months

8.4.b.

The chain link door to enter the arena seating is inaccessible because there is a slope of 10.3% within the door´s required maneuvering clearance.

D13

12 months

8.4.c.

The rodeo area, containing 1,200 seats, is inaccessible because only 7 wheelchair seating areas are provided (each wheelchair seating cutout is not wide enough for two wheelchairs), the wheelchair seating areas are only 27 inches deep, the fixed companion seating does not line up next to the wheelchair seating, and the lines of sight from the wheelchair seating are not comparable to the rest of the seating (in part because of the obstructed view through the chainlink fence). A total of 13 wheelchair seating areas are required.

AA7

12 months

8.5.

Ramp to Rodeo Area: The ramp is inaccessible because it has a slope of up to 8.7%.

R3

12 months

8.6.

Smaller Show Arena:

   

8.6.a.

The route to the smaller show arena and live stock display area is inaccessible because the surface is not stable, firm, and slip-resistant.

AR1

12 months

8.6.b.

The smaller show arena is inaccessible because no wheelchair seating areas are provided.

AA6

12 months

8.7.

Exhibit Hall:

   

8.7.a.

The door is inaccessible because there is a 1.25 inch high threshold.

D23

12 months

8.7.b.

The men´s and women´s toilet rooms contain a number of inaccessible elements and are not accessible to people with disabilities.

TR22

12 months

8.8.

Mary Hough Building: The route is inaccessible because it has a slope of 11.3%.

AR1

12 months

 

Project Civic Access | archive.ADA.gov Home Page