Please Note: Paragraph 54 of the Agreement requires that, within three months of the effective date of this Agreement, the County will provide signage as necessary to comply with 28 C.F.R. § 35.163(b), after having surveyed all facilities that are the subject of this Agreement for the purpose of identifying those that have multiple entrances not all of which are accessible.
The technical requirements and, where appropriate, the scoping requirements of the Standards are used as a guide for determining whether a program or activity held in an existing facility is “readily accessible to and usable by” persons with disabilities and for determining what changes are necessary to make this program or activity accessible if it continues to be provided in the existing facility in question. See 28 C.F.R. §§ 35.150(b)(1), 35.151.
The chart below lists the facilities surveyed by the Department, the access issues identified during the survey, and the actions required to correct the access issues. Required actions are listed using an alphanumeric code. The key to the alphanumeric codes is provided in Attachment M to this Agreement.
In order to ensure that the programs, services, and activities housed in the County’s facilities are accessible to persons with disabilities, when viewed in their entirety, the County will take the actions referenced by the alphanumeric code and described in detail in Attachment M to this Settlement Agreement within the time period specified below, which time period begins to run on the effective date of this Agreement.
Item # |
Access Issue |
Required Action |
Completion Date |
---|---|---|---|
1. |
Ronnie H. Polston County Building, located at 10110 Compton, Flour Bluff |
|
|
1.1. |
Parking |
|
|
1.1.1. |
The parking lot, with a total of 32 parking spaces, is inaccessible because there is no designated van accessible parking space. This lot requires one van accessible space and one standard accessible space. |
P5 |
24 months |
1.1.2. |
The curb ramps are inaccessible because they have slopes of up to 12.1%, and they encroach on the access aisles. |
AR4 |
24 months |
1.2. |
Constable Office Reception Area: The counter is inaccessible because it is 41 inches high and the clear floor space is obstructed by chairs. |
C1 |
18 months |
1.3. |
Justice of the Peace Reception Area |
|
|
1.3.1. |
The counters are inaccessible because they are 37 and 41 inches high. |
C1 |
18 months |
1.3.2. |
The reception area is inaccessible because the counters protrude into the walkway and are not detectable to blind persons using a cane. |
AR7 |
18 months |
1.4. |
Justice of the Peace Waiting Area Women’s Toilet Room with Stalls |
|
|
1.4.1. |
The toilet room is inaccessible because, although the facility contains a fire alarm system, there are no visible alarms provided in the toilet rooms. |
AL1 |
18 months |
1.4.2. |
The toilet room is inaccessible because there is no standard accessible toilet compartment provided. |
TR2 |
18 months |
1.5. |
Justice of the Peace Waiting Area Men’s Toilet Room with Stalls |
|
|
1.5.1. |
The toilet room is inaccessible because, although the facility contains a fire alarm system, there are no visible alarms provided in the toilet rooms. |
AL1 |
18 months |
1.5.2. |
The lavatory is inaccessible because the water supply and drain pipes are not insulated or otherwise configured to protect against contact. |
LS2 |
18 months |
1.5.3. |
The urinal is inaccessible because the rim is 23 1/2 inches high and the flush control is 54 inches high. |
TR8 |
18 months |
1.5.4. |
The toilet room is inaccessible because there is no standard accessible toilet compartment provided. |
TR2 |
6 months |
1.6. |
Justice of the Peace Waiting Area Drinking Fountain: Although a designated accessible drinking fountain is provided, there is no drinking fountain provided for people who have difficulty bending or stooping. |
DF3 |
18months |
1.7. |
Courtroom 106: The Courtroom is inaccessible because there is no assistive listening system provided. |
AA4 |
18 months |
1.8. |
Jury Room 107: The jury room toilet room contains a number of inaccessible elements and is not accessible to people with disabilities. |
TR1 |
18 months |
2. |
County Building and Bishop Branch Library, located at 115 S. Ash, Bishop |
|
|
2.1. |
Entrances: The building is inaccessible because it does not have directional signage posted at inaccessible entrances and does not have the International Symbol of Accessibility posted at accessible entrances. |
D10 |
24 months |
2.2. |
Library: At the time of the site survey, the Library was closed for renovations. Ensure that any alterations made comply with the 2010 ADA Standards for Accessible Design. |
Att. M |
24 months |
2.3. |
Tax Office: At the time of the site survey, the Tax Office was closed for renovations. Ensure that any alterations made comply with the 2010 ADA Standards for Accessible Design. |
Att. M |
24 months |
2.4. |
Interior Signage: The signage provided throughout the facility is inaccessible because it does not have Braille characters. |
D15 |
24 months |
2.5. |
Doors: The doors throughout the facility are inaccessible because the knob hardware requires tight grasping, pinching, or twisting of the wrist to operate. |
D2 |
24 months |
2.6. |
Ramp to Justice of the Peace Entrance |
|
|
2.6.1. |
The ramp is inaccessible because it has a slope of up to 11.2%. |
R4 |
24 months |
2.6.2. |
The ramp is inaccessible because it does not have edge protection. |
R3 |
24 months |
2.7. |
Ramp to Courtroom Entrance: The ramp is inaccessible because it has a slope of up to 11.2%. |
R4 |
24 months |
2.8. |
Women’s Single-User Toilet Room near Courtroom |
|
|
2.8.1. |
The toilet room is inaccessible because the sign has no raised or Braille characters and is mounted on the pull side of the door. |
TR11 |
24 months |
2.8.2. |
The door is inaccessible because the knob hardware requires tight grasping, pinching, or twisting of the wrist to operate. |
D2 |
24 months |
2.8.3. |
The lavatory is inaccessible because the hardware requires twisting of the wrist to operate. |
LS4 |
24 months |
2.8.4. |
The toilet is inaccessible because the centerline is 21 inches from the side wall. |
TR7 |
24 months |
2.9. |
Men’s Single-User Toilet Room near Courtroom |
|
|
2.9.1. |
The toilet room is inaccessible because the sign has no raised or Braille characters and is mounted on the pull side of the door. |
TR11 |
24 months |
2.9.2. |
The door is inaccessible because the knob hardware requires tight grasping, pinching, or twisting of the wrist to operate. |
D2 |
24 months |
2.9.3. |
The lavatory is inaccessible because the hardware requires twisting of the wrist to operate. |
LS4 |
24 months |
2.9.4. |
The toilet is inaccessible because the centerline is 20 inches from the side wall. |
TR7 |
24 months |
2.9.5. |
The toilet is inaccessible because the flush control is on the closed side. |
TR4 |
24 months |
2.10. |
Toilet Rooms with Stalls near Courtroom: Although these toilet rooms are inaccessible, there is no signage directing people with disabilities to the more accessible single-user toilet rooms. |
TR10 |
24 months |
2.11. |
Courtroom: The witness stand and jury box are inaccessible because they can be accessed only by steps. |
AA8 |
24 months |
3. |
Nueces County Park, 415 Mainer Street, Robstown |
|
|
3.1. |
Parking Lot by Playground: The parking lot, with space for a total of approximately 100 parking spaces, has no designated accessible spaces provided. This lot requires one van accessible space and three (if there are 100 or fewer spaces) or four (if there are 101 or more spaces) standard accessible spaces. |
P1 |
30 months |
3.2 |
Exterior Routes: The routes among the various amenities, including the baseball fields, bleachers, tennis courts, picnic tables, playground, play equipment, and basketball court, are inaccessible because the grass surfaces are not firm, stable, and slip resistant; the sidewalk is broken up in some areas, creating changes in level; and many of the routes contain steps, including the routes onto the tennis court, onto the ramp to the concessions, and into the playground. |
AR1 |
30 months |
3.3. |
Toilet Rooms: The toilet rooms in the pavilion and by the old baseball field are inaccessible and there is no signage directing people with disabilities to the accessible toilet rooms. |
TR10 |
24 months |
3.4. |
Drinking Fountains: The drinking fountains throughout the park contain a number of inaccessible elements and are not accessible to people with disabilities. |
DF1 |
24 months |
3.5. |
Old Baseball Field Concession Stand: The counter is inaccessible because it is 43 inches high. |
C1 |
24 months |
3.6. |
Parking Lot by New Baseball Field: The parking lot, with space for a total of approximately 100 parking spaces, has one designated accessible space provided. This lot requires one van accessible space and three (if there are 100 or fewer spaces) or four (if there are 101 or more spaces) standard accessible spaces. |
P1 |
24 months |
3.7. |
New Baseball Field Women’s Toilet Room with Stalls |
|
|
3.7.1. |
The toilet room is inaccessible because the paper towel dispenser protrudes into the walkway and is not detectable to blind persons using a cane. |
AR7 |
24 months |
3.7.2. |
The paper towel dispenser is inaccessible because it is mounted with the controls 55 inches high. |
CT4 |
24 months |
3.7.3. |
The toilet is inaccessible because the centerline is 22 inches from the side wall. |
TR7 |
24 months |
3.8. |
New Baseball Field Men’s Toilet Room with Stalls |
|
|
3.8.1. |
The toilet room is inaccessible because the paper towel dispenser protrudes into the walkway and is not detectable to blind persons using a cane. |
AR7 |
24 months |
3.8.2. |
The toilet is inaccessible because the centerline is 21 inches from the side wall. |
TR7 |
6 months |
4. |
Nueces County Community Center, located at 415 Mainer Street, Robstown |
|
|
4.1. |
Parking |
|
|
4.1.1. |
Three of the designated accessible parking spaces are inaccessible because they have no access aisles. |
P2 |
24 months |
4.1.2. |
The parking lot is inaccessible because there is no designated van accessible parking space. |
P5 |
24 months |
4.2. |
Entrances |
|
|
4.2.1. |
The entrance ramp is inaccessible because it has no handrails. |
R2 |
24 months |
4.2.2. |
The building is inaccessible because it does not have directional signage posted at inaccessible entrances and does not have the International Symbol of Accessibility posted at accessible entrances. |
D10 |
24 months |
4.3. |
Interior Signage: The signage provided throughout the facility is inaccessible because it does not have raised and Braille characters. |
D15 |
24 months |
4.4. |
Men’s Toilet Room with Stalls |
|
|
4.4.1. |
The coat hook is inaccessible because it is mounted 67 inches high. |
TR3 |
24 months |
4.4.2. |
The toilet is inaccessible because the rear grab bar is obstructed by the toilet paper dispenser. |
TR15 |
24 months |
4.4.3. |
The toilet is inaccessible because the centerline is 21 inches from the side wall. |
TR7 |
24 months |
4.4.4. |
The shower is inaccessible because it has a 4 inch high curb at the entrance. |
B3 |
24 months |
4.5. |
Women’s Toilet Room with Stalls |
|
|
4.5.1. |
The coat hook is inaccessible because it is mounted 67 inches high. |
TR3 |
24 months |
4.5.2. |
The lavatory is inaccessible because the water supply and drain pipes are not insulated or otherwise configured to protect against contact. |
LS2 |
24 months |
4.5.3. |
The toilet is inaccessible because the flush control is on the closed side. |
TR4 |
24 months |
4.5.4. |
The toilet is inaccessible because the rear grab bar is obstructed by the toilet paper dispenser. |
TR15 |
24 months |
4.5.5. |
The toilet room is inaccessible because the paper towel dispenser protrudes into the walkway and is not detectable to blind persons using a cane. |
AR7 |
24 months |
4.5.6. |
The shower is inaccessible because it has a 4 inch high curb at the entrance. |
B3 |
24 months |
4.6. |
Drinking Fountain |
|
|
4.6.1. |
Although a designated accessible drinking fountain is provided, there is no drinking fountain provided for people who have difficulty bending or stooping. |
DF3 |
24 months |
4.6.2. |
This area is inaccessible because the drinking fountain protrudes into the walkway and is not detectable to blind persons using a cane. |
AR7 |
24 months |
5. |
County Courthouse and Administration Building, located at 901 Leopard Street, Corpus Christi |
|
|
5.1. |
Parking Lots |
|
|
5.1.1. |
The parking lot at Carrizo and Mestina Streets is inaccessible because there is no van accessible space provided. |
P5 |
30 months |
5.1.2. |
The parking lot at Carrizo and Mestina Streets is inaccessible because the curb ramp encroaches into the access aisle. |
AR4 |
30 months |
5.1.3. |
The other parking lots are inaccessible because they have no designated accessible spaces provided. |
P1 |
30 months |
5.2. |
Assembly Areas: The courtrooms throughout the building are inaccessible because there is no assistive listening system provided. |
AA4 |
30 months |
5.3. |
Hallways: Various hallways are inaccessible because the Automated External Defibrillators protrude into the walkway and are not detectable to blind persons using a cane. |
AR7 |
30 months |
5.4. |
Interior Doors: The doors throughout the facility are inaccessible because they require more than 5 pounds of force to open. |
D3 |
30 months |
5.5. |
Counters: The counters throughout the facility are inaccessible because they are more than 36 inches high. |
C1 |
30 months |
5.6. |
1st Floor Women’s Toilet Room with Stalls near Jury Room |
|
|
5.6.1. |
The lavatory is inaccessible because the water supply and drain pipes are not insulated or otherwise configured to protect against contact. |
LS2 |
30 months |
5.6.2. |
The paper towel dispenser is inaccessible because it is mounted with the controls 62 inches high. |
CT4 |
30 months |
5.6.3. |
The toilet compartment is inaccessible because the door swings into the toilet’s clear floor space. |
TR25 |
30 months |
5.6.4. |
The toilet is inaccessible because the side grab bar is mounted with the far end 49 inches from the rear wall. |
TR17 |
30 months |
5.6.5. |
The toilet room is inaccessible because the two sanitary napkin dispensers protrude into the walkway and are not detectable to blind persons using a cane. |
AR7 |
30 months |
5.7. |
1st Floor Men’s Toilet Room with Stalls by Jury Room |
|
|
5.7.1. |
The lavatory is inaccessible because the water supply and drain pipes are not insulated or otherwise configured to protect against contact. |
LS2 |
30 months |
5.7.2. |
The paper towel dispenser is inaccessible because it is mounted with the controls 62 inches high. |
CT4 |
30 months |
5.7.3. |
The toilet compartment is inaccessible because the door swings into the toilet’s clear floor space. |
TR25 |
30 months |
5.7.4. |
The toilet is inaccessible because the side grab bar is mounted with the far end 50 inches from the rear wall. |
TR17 |
30 months |
5.8. |
1st Floor Toilet Rooms by Justice of the Peace: Although these toilet rooms are inaccessible, there is no signage directing people with disabilities to the designated accessible toilet rooms. |
TR10 |
30 months |
5.9. |
1st Floor Public Telephone by Justice of the Peace: The telephone is inaccessible because the volume control is broken. |
TT1 |
30 months |
5.10. |
Elevators: The elevators are inaccessible because the emergency communication systems do not work without voice communication. |
E7 |
30 months |
5.11. |
3rd Floor County Clerk - Records: The unisex, single-user toilet room contains a number of inaccessible elements and is not accessible to people with disabilities. |
TR1 |
30 months |
5.12. |
3rd Floor Men’s Toilet Room with Stalls: The toilet is inaccessible because the side grab bar is mounted with the far end 48 inches from the rear wall. |
TR17 |
30 months |
5.13. |
3rd Floor Drinking Fountains by Toilet Rooms: The drinking fountains are inaccessible because the flow of water is 3 inches high. |
DF5 |
30 months |
5.14. |
3rd Floor Women’s Toilet Room with Stalls |
|
|
5.14.1. |
The toilet is inaccessible because the centerline is 19 1/2 inches from the side wall. |
TR7 |
30 months |
5.14.2. |
The toilet is inaccessible because the top of the seat is 19 3/4 inches high. |
TR9 |
30 months |
5.14.3. |
The toilet is inaccessible because the side grab bar is mounted with the far end 47 inches from the rear wall. |
TR17 |
30 months |
5.15. |
3rd Floor Wing Men’s Single-User Toilet Room |
|
|
5.15.1. |
The toilet is inaccessible because the centerline is 15 inches from the side wall. |
TR7 |
30 months |
5.15.2. |
The toilet is inaccessible because the side grab bar is mounted 2 inches from the wall on which it is mounted. |
TR20 |
30 months |
5.15.3. |
The toilet is inaccessible because the side grab bar is obstructed by the toilet paper dispenser. |
TR15 |
30 months |
5.15.4. |
The toilet is inaccessible because the rear grab bar is 30 inches long. |
TR14 |
30 months |
5.16. |
3rd Floor Wing Women’s Single-User Toilet Room |
|
|
5.16.1. |
The toilet is inaccessible because the centerline is 15 inches from the side wall. |
TR7 |
30 months |
5.16.2. |
The toilet is inaccessible because the side grab bar is mounted 2 inches from the wall on which it is mounted. |
TR20 |
30 months |
5.16.3. |
The toilet is inaccessible because the side grab bar is obstructed by the toilet paper dispenser. |
TR15 |
30 months |
5.16.4. |
The toilet is inaccessible because the rear grab bar is 30 inches long. |
TR14 |
30 months |
5.16.5. |
The coat hook is inaccessible because it is mounted 60 inches high. |
TR3 |
30 months |
5.17. |
Room 310 Community Supervision and Corrections Department: The door is inaccessible because the knob hardware requires tight grasping, pinching, or twisting of the wrist to operate. |
D2 |
30 months |
5.18. |
2nd Floor Wing Drinking Fountain: The drinking fountain contains a number of inaccessible elements and is not accessible to people with disabilities. |
DF1 |
30 months |
5.19. |
2nd Floor Wing Women’s Single-User Toilet Room |
|
|
5.19.1. |
The toilet room is inaccessible because the sanitary napkin dispenser protrudes into the walkway and is not detectable to blind persons using a cane. |
AR7 |
30 months |
5.19.2 |
The toilet is inaccessible because the side grab bar is mounted with the far end 48 inches from the rear wall. |
TR17 |
30 months |
5.20. |
2nd Floor Wing District Attorney’s Office: The door is inaccessible because the knob hardware requires tight grasping, pinching, or twisting of the wrist to operate. |
D2 |
30 months |
5.21. |
2nd Floor Wing Men’s Single-User Toilet Room: The toilet is inaccessible because the side grab bar is mounted with the far end 48 inches from the rear wall. |
TR17 |
30 months |
5.22 |
1st Floor Wing Texas Rio Grande Legal Aid Room 105: The door is inaccessible because the knob hardware requires tight grasping, pinching, or twisting of the wrist to operate. |
D2 |
30 months |
5.23. |
1st Floor Wing Men’s Single-User Toilet Room |
|
|
5.23.1 |
The lavatory is inaccessible because the water supply and drain pipes are not insulated or otherwise configured to protect against contact. |
LS2 |
30 months |
5.23.2. |
The toilet is inaccessible because the centerline is 15 inches from the side wall. |
TR7 |
30 months |
5.23.3. |
The toilet is inaccessible because the rear grab bar is 30 inches long. |
TR14 |
30 months |
5.23.4. |
The toilet is inaccessible because the side grab bar is mounted 2 inches from the wall on which it is mounted. |
TR20 |
30 months |
5.24. |
1st Floor Wing Women’s Single-User Toilet Room |
|
|
5.24.1. |
The lavatory is inaccessible because the water supply and drain pipes are not insulated or otherwise configured to protect against contact. |
LS2 |
30 months |
5.24.2. |
The toilet is inaccessible because the centerline is 14 1/2 inches from the side wall. |
TR7 |
30 months |
5.24.3. |
The toilet is inaccessible because the side grab bar is obstructed by the toilet paper dispenser. |
TR15 |
30 months |
5.24.4. |
The toilet is inaccessible because the rear grab bar is 30 inches long. |
TR14 |
30 months |
5.24.5. |
The toilet is inaccessible because the side grab bar is mounted 2 inches from the wall on which it is mounted. |
TR20 |
30 months |
5.25. |
1st Floor Wing Drinking Fountain: This area is inaccessible because the drinking fountain protrudes into the walkway and is not detectable to blind persons using a cane. |
AR7 |
30 months |
5.26. |
4th Floor Grand Jury Courtroom Women’s Single-User Toilet Room |
|
|
5.26.1. |
The lavatory is inaccessible because the water supply and drain pipes are not insulated or otherwise configured to protect against contact. |
LS2 |
30 months |
5.26.2. |
The lavatory is inaccessible because the hardware requires twisting of the wrist and more than 5 pounds of force to operate. |
LS4 |
30 months |
5.26.3. |
The paper towel dispenser is inaccessible because it is mounted 56 inches high over the counter. |
CT3 |
30 months |
5.26.4. |
The toilet is inaccessible because the flush control is on the closed side. |
TR4 |
30 months |
5.26.5. |
The toilet is inaccessible because the side grab bar is mounted with the far end 49 inches from the rear wall. |
TR17 |
30 months |
5.26.6. |
The toilet room is inaccessible because the sanitary napkin dispenser protrudes into the walkway and is not detectable to blind persons using a cane. |
AR7 |
30 months |
5.27. |
4th Floor Grand Jury Courtroom Men’s Single-User Toilet Room |
|
|
5.27.1. |
The lavatory is inaccessible because the water supply and drain pipes are not insulated or otherwise configured to protect against contact. |
LS2 |
30 months |
5.27.2. |
The lavatory is inaccessible because the hardware requires twisting of the wrist and more than 5 pounds of force to operate. |
LS4 |
30 months |
5.27.3. |
The paper towel dispenser is inaccessible because it is mounted 56 inches high over the counter. |
CT3 |
30 months |
5.27.4. |
The urinal is inaccessible because the rim is 24 inches high. |
TR8 |
30 months |
5.27.5. |
The toilet is inaccessible because the top of the seat is 14 3/4 inches high. |
TR9 |
30 months |
5.27.6. |
The toilet is inaccessible because the flush control is on the closed side. |
TR4 |
30 months |
5.28. |
4th Floor Courtroom: The witness stand is inaccessible because it can be accessed only by steps. |
AA8 |
30 months |
5.29. |
4th Floor Courtroom Jury Room Unisex Single-User Toilet Room |
|
|
5.29.1. |
The coat hook is inaccessible because it is mounted 67 inches high. |
TR3 |
30 months |
5.29.2. |
The toilet is inaccessible because the flush control is on the closed side. |
TR4 |
30 months |
5.30. |
4th Floor Drinking Fountain: The drinking fountain contains a number of inaccessible elements and is not accessible to people with disabilities. |
DF1 |
30 months |
5.31. |
4th Floor Hallway Women’s Toilet Room with Stall |
|
|
5.31.1. |
The toilet room is inaccessible because the sign has no raised or Braille characters and is mounted on the door. |
TR11 |
30 months |
5.31.2. |
The lavatory is inaccessible because the water supply and drain pipes are not insulated or otherwise configured to protect against contact. |
LS2 |
30 months |
5.31.3. |
The paper towel dispenser is inaccessible because it is mounted 51 inches high behind the lavatory. |
CT3 |
30 months |
5.31.4. |
The soap dispenser is inaccessible because it is mounted 55 inches high. |
CT4 |
30 months |
5.31.5. |
The toilet room is inaccessible because the toilet compartment is 54 inches deep. |
TR23 |
30 months |
5.31.6. |
The toilet room is inaccessible because the sanitary napkin dispenser and air dryer protrude into the walkway and are not detectable to blind persons using a cane. |
AR7 |
30 months |
5.32. |
4th Floor Hallway Men’s Toilet Room with Stall |
|
|
5.32.1. |
The toilet room is inaccessible because the sign has no raised or Braille characters. |
TR11 |
30 months |
5.32.2. |
The lavatory is inaccessible because the water supply and drain pipes are not insulated or otherwise configured to protect against contact. |
LS2 |
30 months |
5.32.3. |
The toilet room is inaccessible because the air dryer protrudes into the walkway and is not detectable to blind persons using a cane. |
AR7 |
30 months |
5.33. |
4th Floor Dispute Resolution 401.2: The door is inaccessible because the knob hardware requires tight grasping, pinching, or twisting of the wrist to operate. |
D2 |
30 months |
5.34. |
4th Floor Administrative Office of the Court: The door is inaccessible because the knob hardware requires tight grasping, pinching, or twisting of the wrist to operate. |
D2 |
30 months |
5.35. |
Toilet Rooms on 5th through 10th Floors: Although these toilet rooms are inaccessible, there is no signage directing people with disabilities to the accessible toilet rooms. |
TR10 |
30 months |
5.36. |
Drinking Fountains on 6th through 10th Floors: The drinking fountains contain a number of inaccessible elements and are not accessible to people with disabilities. |
DF1 |
30 months |
5.37. |
6nd Floor Library |
|
|
5.37.1. |
The study rooms are inaccessible because the knob hardware requires tight grasping, pinching, or twisting of the wrist to operate. |
D2 |
30 months |
5.37.2. |
The study rooms are inaccessible because the doors have opening widths of 30 inches. |
D14 |
30 months |
5.38. |
Courtrooms on 7th and 8th Floors |
|
|
5.38.1. |
The witness stand is inaccessible because it can be accessed only by steps. |
AA8 |
30 months |
5.38.2. |
The Jury Room is inaccessible because the knob hardware requires tight grasping, pinching, or twisting of the wrist to operate. |
D2 |
30 months |
5.38.3. |
The Jury Room toilet room contains a number of inaccessible elements and is not accessible to people with disabilities. |
TR1 |
30 months |
5.39. |
Holding Cells on 7th, 8th, and 9th Floors: There are no accessible holding cells provided. |
PJ1 |
30 months |
5.40. |
10th Floor Courtroom: The counsel’s tables are inaccessible because they provide only 25 inches of clear knee space. |
DW1 |
30 months |
6. |
Nueces County Constable and Justice of the Peace, located at 1514 2nd Street, Agua Dulce |
|
|
6.1. |
Parking: The parking lot is inaccessible because it has no van accessible parking space. |
P5 |
24 months |
6.2. |
Ramp from Parking to East Side Entrance |
|
|
6.2.1. |
The ramp is inaccessible because it does not have edge protection. |
R3 |
24 months |
6.2.2. |
The ramp is inaccessible because it lacks a handrail on one side. |
R2 |
24 months |
6.3. |
Interior Signage: The signage provided is inaccessible because it does not have raised and Braille characters. |
D15 |
24 months |
6.4. |
Justice of the Peace Courtroom |
|
|
6.4.1. |
The door is inaccessible because the knob hardware requires tight grasping, pinching, or twisting of the wrist to operate. |
D2 |
24 months |
6.4.2. |
The witness stand and jury box are inaccessible because they can be accessed only by steps. |
AA8 |
24 months |
6.5. |
Interior Route: The hallway is inaccessible because the Automated External Defibrillator protrudes into the walkway and is not detectable to blind persons using a cane. |
AR7 |
24 months |
6.6. |
Constable’s Office |
|
|
6.6.1. |
The counter is inaccessible because it is 42 inches high. |
C1 |
24 months |
6.6.2. |
The office is inaccessible because the counter protrudes into the walkway and is not detectable to blind persons using a cane. |
AR7 |
24 months |
6.7. |
Toilet Rooms: The toilet rooms contain a number of inaccessible elements and are not accessible to people with disabilities. |
TR1 |
24 months |
6.8. |
Drinking Fountain |
|
|
6.8.1. |
Although a designated accessible drinking fountain is provided, there is no drinking fountain provided for people who have difficulty bending or stooping. |
DF3 |
24 months |
6.8.2. |
This area is inaccessible because the drinking fountain protrudes into the walkway and is not detectable to blind persons using a cane. |
AR7 |
24 months |
7. |
David Berlanga Sr. Building, located at 1513 2nd Street, Agua Dulce |
|
|
7.1. |
Parking: The parking lot, with a total of 22 parking spaces, is inaccessible because there are no access aisles and no van accessible space provided. This lot requires one van accessible space. |
P5 |
24 months |
7.2. |
Entrances: The building is inaccessible because it does not have directional signage posted at inaccessible entrances and does not have the International Symbol of Accessibility posted at accessible entrances. |
D10 |
24 months |
7.3. |
Counter at Entrance |
|
|
7.3.1. |
The counter is inaccessible because it is 39 inches high. |
C1 |
24 months |
7.3.2. |
This area is inaccessible because the counter protrudes into the walkway and is not detectable to blind persons using a cane. |
AR7 |
24 months |
7.4. |
Women’s Single-User Toilet Room |
|
|
7.4.1. |
The toilet room is inaccessible because the sign is mounted on the pull side of the door. |
TR11 |
24 months |
7.4.2. |
The door is inaccessible because it requires 10 pounds of force to open. |
D3 |
24 months |
7.4.3. |
No accessible mirror has been provided. |
TR5 |
24 months |
7.4.4. |
The toilet is inaccessible because it is mounted too far from the side wall. |
TR7 |
24 months |
7.4.5. |
The toilet is inaccessible because the rear grab bar is obstructed by the paper towel dispenser. |
TR15 |
24 months |
7.5. |
Men’s Single-User Toilet Room |
|
|
7.5.1. |
The toilet room is inaccessible because the sign is mounted on the pull side of the door. |
TR11 |
24 months |
7.5.2. |
The pull side of the door is inaccessible because it has only 3 inches of clear space on the latch side. |
D5 |
24 months |
7.5.3. |
The door is inaccessible because it requires 10 pounds of force to open. |
D3 |
24 months |
7.5.4. |
No accessible mirror has been provided. |
TR5 |
24 months |
7.5.5. |
The toilet is inaccessible because the rear grab bar is obstructed by the paper towel dispenser. |
TR15 |
24 months |
7.6. |
Drinking Fountain: Although a designated accessible drinking fountain is provided, there is no drinking fountain provided for people who have difficulty bending or stooping. |
DF3 |
24 months |
8. |
Magee Beach Park, located at 848 East Cotter Avenue, Port Aransas |
|
|
8.1. |
Parking: The van accessible parking space is inaccessible because it lacks a “van accessible” sign. |
P3 |
18 months |
8.2. |
Entrances: The building is inaccessible because it does not have directional signage posted at inaccessible entrances and does not have the International Symbol of Accessibility posted at accessible entrances. |
D10 |
18 months |
8.3. |
Unisex, Single-User Toilet Room Near Laundry Facilities |
|
|
8.3.1. |
The door is inaccessible because it requires 13 pounds of force to open. |
D3 |
18 months |
8.3.2. |
The toilet is inaccessible because the side grab bar is mounted 18 inches from the rear wall. |
TR17 |
18 months |
8.4. |
Reception Area Unisex Single-User Toilet Room: The door is inaccessible because it requires 10 pounds of force to open. |
D3 |
18 months |
8.5. |
Drinking Fountain by Visitors’ Showers: This area is inaccessible because the higher fountain protrudes into the walkway and is not detectable to blind persons using a cane. |
AR7 |
18 months |
8.6. |
Women’s Locker Room in Park Office |
|
|
8.6.1. |
The roll-in shower is inaccessible because the folding seat is mounted with the “L” extension on the wrong side, the seat is mounted 8 inches from the control wall, and there are grab bars mounted behind the seat. |
B2 |
18 months |
8.6.2. |
The bench is inaccessible because it is 12 inches deep and it is less than 42 inches long. |
LR2 |
18 months |
8.7. |
Horace Caldwell Pier Parking: The parking lot, with a total of 57 parking spaces, is inaccessible because there are two designated accessible parking spaces, there is no vertical signage, and there is no van accessible space. This lot requires one van accessible space and two standard accessible spaces. |
P1 |
18 months |
8.8. |
Ramp to Pier: The ramp is inaccessible because the handrail lacks an extension at the top. |
R2 |
18 months |
8.9. |
Gate: The gate is inaccessible because the knob hardware requires tight grasping, pinching, or twisting of the wrist to operate. |
D2 |
18 months |
8.10. |
Gift Store and Restaurant: The door is inaccessible because it has a 1 1/4 inch high threshold. |
D12 |
18 months |
9. |
Packery Channel Park, located at 14218 South Padre Island Drive, Corpus Christi |
|
|
9.1. |
Parking: The parking lot, with space for approximately eight parking spaces, has no designated accessible spaces provided. This lot requires one van accessible space. |
P1 |
18 months |
9.2. |
Nature Boardwalk |
|
|
9.2.1. |
The route from the parking lot to the boardwalk is inaccessible because the grass and gravel surface is not firm, stable, and slip resistant, and the concrete platform just in front of the boardwalk has a slope of 15.9%. |
AR1 |
18 months |
9.2.2. |
The boardwalk is inaccessible because it has a slope of up to 10%. |
R4 |
18 months |
9.3. |
Unisex Single-User Toilet Room: This facility was locked and could not be surveyed. |
TR1 |
18 months |
9.4. |
Kayak Launch Parking: The parking lot has no designated accessible spaces provided. |
P1 |
18 months |
10. |
John J. Sablatura Park, located at 5905 Highway 44, Banquete |
|
|
10.1. |
Parking: The parking lot, with a total of 25 parking spaces, is inaccessible because it has no designated accessible spaces provided. This lot requires one van accessible space. |
P5 |
30 months |
10.2. |
Exterior Routes: The park is inaccessible because there are no accessible routes to the park’s amenities, including toilet rooms and picnic areas. |
AR1 |
30 months |