ATTACHMENT J: Modifications to Altered Facilities

Please Note: Paragraph 54 of the Settlement Agreement requires that within three months of the effective date of this Agreement, the County provide signage as necessary to comply with 28 C.F.R. § 35.163(b), after having surveyed all facilities that are the subject of this Agreement for the purpose of identifying those that have multiple entrances not all of which are accessible.

The chart below lists the facilities surveyed by the Department, the access issues identified during the survey, and the actions required to correct the access issues. Required actions are listed using an alphanumeric code. The key to the alphanumeric codes is provided in Attachment M to this Agreement.

In order to ensure that the following spaces and elements in the County's facilities in which alterations occurred after January 26, 1992, are readily accessible to and usable by persons with disabilities, the County will take the actions referenced by the alphanumeric code and described in detail in Attachment M to this Settlement Agreement within the time period specified below, which time period will begin to run on the effective date of this Agreement.

 

Item #

 

Access Issue

Required Action

Completion Date

1.

 

Agua Dulce Park, located at 1708 2nd Street, Agua Dulce

 

 

1.1.

 

Exterior Routes: The routes to many amenities, including the playground, grills, and swings, are inaccessible because the grass surfaces are not firm, stable, and slip resistant.

 

AR1

 

18 months

1.2.

 

Women's Toilet Room with Stalls: The toilet paper dispenser is inaccessible because it is mounted too far in front of the toilet.

 

TR6

 

15 months

1.3.

 

Men's Toilet Room with Stalls

 

 

1.3.1

 

The toilet paper dispenser is inaccessible because it is mounted too far in front of the toilet.

 

TR6

 

15 months

1.3.2.

 

The soap dispenser is inaccessible because it is mounted 50 inches high between the lavatories.

 

CT3

 

15 months

2.

 

Amistad Veterans Memorial Park, 200 Avenue J, Bishop

 

 

2.1.

 

Exterior Routes: The routes to many amenities, including the swings, playground, and jungle gym, are inaccessible because the grass surfaces are not firm, stable, and slip resistant.

 

AR1

 

18 months

2.2.

 

Men's Toilet Room with Stalls

 

 

2.2.1.

 

The toilet room is inaccessible because the sign has no raised or Braille characters and is mounted on the pull side of the door.

 

TR11

 

15 months

2.2.2.

 

The coat hook is inaccessible because it is mounted 58 inches high.

 

TR3

 

15 months

2.2.3.

 

The toilet is inaccessible because the side grab bar is mounted with the far end 48 inches from the rear wall.

 

TR17

 

15 months

2.3.

 

Women's Toilet Room with Stalls

 

 

2.3.1.

 

The toilet room is inaccessible because the sign has no raised or Braille characters and is mounted on the pull side of the door.

 

TR11

 

15 months

2.3.2.

 

The coat hook is inaccessible because it is mounted 55 inches high.

 

TR3

 

15 months

2.4.

 

Drinking Fountain Near Picnic Pavilion: The drinking fountain contains a number of inaccessible elements and is not accessible to people with disabilities.

 

DF1

 

24 months

3.

 

Calderon Building, located at 710 E. Main Street, Robstown

 

 

3.1.

 

Entrances

 

 

3.1.1.

 

The building is inaccessible because it does not have directional signage posted at inaccessible entrances and does not have the International Symbol of Accessibility posted at the designated accessible south entrance.

 

D10

 

12 months

3.1.2.

 

The vestibule between the doors at the south entrance is inaccessible because it is not sufficiently deep.

 

D4

 

30 months

3.2.

 

South Entrance Ramp

 

 

3.2.1.

 

The ramp is inaccessible because it has a slope of up to 10.1%.

 

R4

 

24 months

3.2.2.

 

The ramp is inaccessible because it does not have edge protection.

 

R3

 

24 months

3.2.3.

 

The ramp is inaccessible because the handrails lack extensions.

 

R2

 

24 months

3.3.

 

Interior Doors: The doors throughout the facility are inaccessible because the knob hardware requires tight grasping, pinching, or twisting of the wrist to operate.

 

D2

 

24 months

3.4.

 

Interior Signage: The signage throughout the facility is inaccessible because it lacks raised and Braille characters.

 

D15

 

24 months

3.5.

 

Justice of the Peace: The counter is inaccessible because it is 40 inches high.

 

C1

 

24 months

3.6.

 

Tax Collector

 

 

3.6.1.

 

The office is inaccessible because the mirror mounted on the door protrudes into the walkway and is not detectable to blind persons using a cane.

 

AR7

 

24 months

3.6.2.

 

The ticket dispenser is inaccessible because it is mounted with the controls 61 inches high.

 

CT4

 

24 months

3.6.3.

 

The counter is inaccessible because it is 42 inches high.

 

C1

 

24 months

3.7.

 

Public Telephone: The telephone is inaccessible because it is mounted 61 inches high to the highest operable part, and it lacks volume control.

 

TT1

 

24 months

3.8.

 

Adult Probation Office

 

 

3.8.1.

 

The door is inaccessible because the threshold is too high.

 

D12

 

30 months

3.8.2.

 

The door is inaccessible because it requires 9 pounds of force to open.

 

D3

 

30 months

3.9.

 

Men's and Women's Toilet Rooms with Stalls: Although these toilet rooms are inaccessible, there is no signage directing people with disabilities to the accessible single-user toilet room located in Adult Probation.

 

TR10

 

30 months

3.10.

 

Clinic

 

 

3.10.1.

 

The counter is inaccessible because it is 49 1/4 inches high.

 

C1

 

30 months

3.10.2.

 

The single-user toilet rooms are inaccessible and there is no signage directing people with disabilities to the accessible toilet room located in Adult Probation.

 

TR10

 

30 months

4.

 

McKinzie Jail Annex, located at 745 N. Padre Island Drive, Corpus Christi

 

 

4.1.

 

Parking for Sheriff's Office and Alternate Incarceration: The parking lot is inaccessible because it has no designated van accessible parking space.

 

P5

 

30 months

4.2.

 

Entrances: The building is inaccessible because it does not have directional signage posted at inaccessible entrances and does not have the International Symbol of Accessibility posted at accessible entrances.

 

D10

 

30 months

4.3.

 

Main Entrance: The vestibule is inaccessible because there is 36 inches between the ends of the open doors swinging into the vestibule.

 

D4

 

30 months

4.4.

 

Alternate Incarceration Entrance

 

 

4.4.1.

 

The route to the entrance is inaccessible because the slopes range from 6.8% to 7.5% and there are no handrails.

 

AR1

 

30 months

4.4.2.

 

The door is inaccessible because the knob hardware requires tight grasping, pinching, or twisting of the wrist to operate.

 

D2

 

30 months

4.4.3.

 

The entrance is inaccessible because the metal container mounted outside the door protrudes into the walkway and is not detectable to blind persons using a cane.

 

AR7

 

30 months

4.5.

 

Community Corrections: The counter is inaccessible because it is 43 1/2 inches high.

 

C1

 

30 months

4.6.

 

Community Corrections Drinking Fountain: Although a designated accessible drinking fountain is provided, there is no drinking fountain provided for people who have difficulty bending or stooping.

 

DF3

 

30 months

4.7.

 

Community Corrections Women's Toilet Room with Stalls

 

 

4.7.1.

 

The toilet room is inaccessible because the sign has no raised or Braille characters.

 

TR11

 

30 months

4.7.2.

 

The pull side of the door is inaccessible because it has only 4 3/4 inches of clear space on the latch side.

 

D5

 

30 months

4.7.3.

 

The door is inaccessible because the knob hardware requires tight grasping, pinching, or twisting of the wrist to operate.

 

D2

 

30 months

4.7.4.

 

The toilet room is inaccessible because, although the facility contains a fire alarm system, there are no visible alarms provided in the toilet room.

 

AL1

 

30 months

4.7.5.

 

The lavatory is inaccessible because there is no knee clearance provided.

 

LS3

 

30 months

4.7.6.

 

The paper towel and soap dispensers are inaccessible because they are each mounted 50 inches high over the lavatory.

 

CT3

 

30 months

4.7.7.

 

The toilet compartment is inaccessible because it is 48 inches wide.

 

TR23

 

30 months

4.7.8.

 

The toilet is inaccessible because the centerline is 24 inches from the side wall.

 

TR7

 

30 months

4.7.9.

 

The toilet is inaccessible because the flush control is on the closed side.

 

TR4

 

30 months

4.7.10.

 

The coat hook is inaccessible because it is mounted 68 inches high.

 

TR3

 

30 months

4.7.11.

 

The toilet is inaccessible because the rear grab bar is mounted with the far end 14 inches from the center of the toilet.

 

TR14

 

30 months

4.8.

 

Community Corrections Men's Toilet Room with Stalls

 

 

4.8.1.

 

The door is inaccessible because it cannot be opened 90 degrees.

 

D14

 

30 months

4.8.2.

 

The door is inaccessible because the knob hardware requires tight grasping, pinching, or twisting of the wrist to operate.

 

D2

 

30 months

4.8.3.

 

The toilet room is inaccessible because, although the facility contains a fire alarm system, there are no visible alarms provided in the toilet room.

 

AL1

 

30 months

4.8.4.

 

No accessible mirror has been provided.

 

TR5

 

30 months

4.8.5.

 

The lavatory is inaccessible because there is no knee clearance provided.

 

LS3

 

30 months

4.8.6.

 

The soap dispenser is inaccessible because it is mounted 50 inches high over the lavatory.

 

CT3

 

30 months

4.8.7.

 

The urinal is inaccessible because the rim is 20 inches high and the clear floor space is less than 30 inches wide.

 

TR8

 

30 months

4.8.8.

 

The toilet is inaccessible because the flush control is on the closed side.

 

TR4

 

30 months

4.8.9.

 

The toilet compartment is inaccessible because it is 55 inches wide.

 

TR23

 

30 months

4.8.10.

 

The toilet is inaccessible because the centerline is 24 1/2 inches from the side wall.

 

TR7

 

30 months

4.8.11.

 

The coat hook is inaccessible because it is mounted 68 inches high.

 

TR3

 

30 months

4.8.12.

 

The toilet is inaccessible because the rear grab bar is mounted with the far end 14 inches from the center of the toilet.

 

TR14

 

30 months

4.9.

 

Sheriff's Office

 

AR7

 

30 months

4.9.1.

 

The route into the Sheriff's Office is inaccessible because it is less than 32 inches wide through the metal detector.

 

AR3

 

30 months

4.9.2.

 

This area is inaccessible because the drinking fountain protrudes into the walkway and is not detectable to blind persons using a cane.

 

AR7

 

30 months

4.10.

 

Sheriff's Office Men's and Women's Single-User Toilet Rooms: Although these toilet rooms are inaccessible, there is no signage directing people with disabilities to the accessible toilet rooms.

 

TR10

 

30 months

4.11.

 

Sheriff's Office Unisex Single-User Toilet Room

 

 

4.11.1.

 

The toilet room is inaccessible because the sign has no raised or Braille characters and is mounted on the pull side of the door.

 

TR11

 

30 months

4.11.2.

 

The door is inaccessible because the knob hardware requires tight grasping, pinching, or twisting of the wrist to operate.

 

D2

 

30 months

4.11.3.

 

The toilet room is inaccessible because, although the facility contains a fire alarm system, there are no visible alarms provided in the toilet room.

 

AL1

 

30 months

4.11.4.

 

No accessible mirror has been provided.

 

TR5

 

30 months

4.11.5.

 

The toilet room is inaccessible because the paper towel dispenser protrudes into the walkway and is not detectable to blind persons using a cane.

 

AR7

 

30 months

4.11.6.

 

The toilet seat cover dispenser is inaccessible because it is mounted 56 inches high behind the toilet.

 

CT3

 

30 months

4.11.7.

 

The toilet is inaccessible because the top of the seat is 20 1/2 inches high.

 

TR9

 

30 months

4.11.8.

 

The toilet is inaccessible because the flush control is on the closed side.

 

TR4

 

30 months

4.12.

 

Sick Call Counter

 

 

4.12.1.

 

The counter is inaccessible because it is 42 inches high.

 

C1

 

30 months

4.12.2.

 

This area is inaccessible because the counter protrudes into the walkway and is not detectable to blind persons using a cane.

 

AR7

 

30 months

4.13.

 

Rec Yard: The route into the yard is inaccessible because it requires traversing stairs.

 

AR2

 

30 months

4.14.

 

Remote Pod for Inmates

 

 

4.14.1.

 

The toilet room contains a number of inaccessible elements and is not accessible to people with disabilities.

 

TR1

 

30 months

4.14.2.

 

There is no accessible shower provided.

 

B2

 

30 months

4.14.3.

 

The common area in the Pod is inaccessible because the tables provide inadequate clear knee space.

 

DW1

 

30 months

4.15.

 

Pods

 

 

4.15.1.

 

There is no accessible cell provided.

 

PJ1

 

30 months

4.15.2.

 

There are no cells provided with communication features.

 

PJ2

 

30 months

4.15.3.

 

The washing machines and dryers are inaccessible because they have controls that are not within accessible reach ranges.

 

WD1

 

30 months

4.16.

 

Dorms

 

 

4.16.1.

 

The microwave is inaccessible because it is mounted with the controls 61 1/2 inches high.

 

CT4

 

30 months

4.16.2.

 

The telephones are inaccessible because they are mounted 58 inches high to the highest operable part.

 

TT1

 

30 months

4.17.

 

Dorms Toilet Room

 

 

30 months

4.17.1.

 

The toilet room contains a number of inaccessible elements and is not accessible to people with disabilities.

 

TR1

 

30 months

4.17.2.

 

There is no accessible shower provided.

 

B2

 

30 months

4.18.

 

Substance Abuse Treatment Facility Parking

 

 

4.18.1.

 

The parking lot is inaccessible because it has no van accessible parking space, the designated accessible space has no vertical sign, and there is a curb ramp obstructing the access aisle.

 

P5

 

30 months

4.18.2.

 

The curb ramp is inaccessible because it has a slope of 10.3% and lacks flared sides, and it obstructs the access aisle.

 

AR4

 

30 months

4.19.

 

Substance Abuse Treatment Facility

 

 

4.19.1.

 

The vestibule of one of the entrances is inaccessible because there are 35 inches of clear space between the face of one door and the end of the open door swinging into the vestibule.

 

D4

 

30 months

4.19.2.

 

The reception area is inaccessible because the counters protrude into the walkway and are not detectable to blind persons using a cane.

 

AR7

 

30 months

4.20.

 

Substance Abuse Treatment Facility Working Residents Dorms

 

 

4.20.1.

 

Although a designated accessible drinking fountain is provided, there is no drinking fountain provided for people who have difficulty bending or stooping.

 

DF3

 

30 months

4.20.2.

 

This area is inaccessible because the drinking fountain protrudes into the walkway and is not detectable to blind persons using a cane.

 

AR7

 

30 months

4.21.

 

Substance Abuse Treatment Facility Working Residents Dorms Toilet Rooms

 

 

4.21.1.

 

No accessible mirror has been provided.

 

TR5

 

30 months

4.21.2.

 

The lavatory is inaccessible because the water supply and drain pipes are not insulated or otherwise configured to protect against contact.

 

LS2

 

30 months

4.21.3.

 

The toilet is inaccessible because the flush control is on the closed side.

 

TR4

 

30 months

4.21.4.

 

The coat hook in the standard accessible toilet stall is inaccessible because it is mounted 68 inches high.

 

TR3

 

30 months

4.21.5.

 

The toilet compartment is inaccessible because the door is not self closing and no pull handle is provided.

 

TR25

 

30 months

4.21.6.

 

There is no accessible shower provided.

 

B2

30 months

4.21.7.

 

The towel hooks provided at the showers are inaccessible because they are mounted 58 inches high.

 

TR3

 

30 months

4.22.

 

Substance Abuse Treatment Facility Non-Working Residents Dorms Sleeping Rooms

 

 

4.22.1.

 

The doors are inaccessible because the knob hardware requires tight grasping, pinching, or twisting of the wrist to operate.

 

D2

 

30 months

4.22.2.

 

The toilet room contains a number of inaccessible elements and is not accessible to people with disabilities.

 

TR1

 

30 months

4.22.3.

 

There is no accessible shower provided.

 

B2

 

30 months

5.

 

Nueces County Jail, located at 901 Leopard Street, Corpus Christi

 

 

5.1.

 

Entrance Ramp: The ramp is inaccessible because it has a slope of 13.6% at the top.

 

R4

 

30 months

5.2.

 

Entrances: The building is inaccessible because it does not have directional signage posted at inaccessible entrances and does not have the International Symbol of Accessibility posted at accessible entrances.

 

D10

 

30 months

5.3.

 

Inmate Intake

 

 

5.3.1.

 

This area is inaccessible because the reception counter protrudes into the walkway and is not detectable to blind persons using a cane.

 

AR7

 

30 months

5.3.2.

 

There is no accessible holding cell provided.

 

PJ1

 

30 months

5.4.

 

Main Reception Counter: The counter is inaccessible because it is 41 1/2 inches high.

 

C1

 

30 months

5.5.

 

Telephones for Inmate Use: The telephones throughout the facility are inaccessible because their cords are less than 29 inches long and they have no volume control.

 

TT1

 

30 months

5.6.

 

Dining Tables: The tables are inaccessible because they provide inadequate clear knee space.

 

DW1

 

30 months

5.7.

 

Public Elevator

 

 

5.7.1.

 

The elevator is inaccessible because the hall signals do not sound once for up and twice for down or have a verbal annunciator.

 

E10

 

30 months

5.7.2.

 

The elevator is inaccessible because the time from notification that a car is answering a call until the doors of that car start to close is 3 seconds.

 

E6

 

30 months

5.8.

 

X-Ray Room: The room is inaccessible because the clear floor space is 27 inches wide between the examining table and the wall.

 

AR10

 

30 months

5.9.

 

Medical Unit Single-User Toilet Room: The toilet room contains a number of inaccessible elements and is not accessible to people with disabilities.

 

TR1

 

30 months

5.10.

 

Medical Unit Cell: There is no accessible cell provided.

 

PJ1

 

30 months

5.11.

 

Medical Unit Shower Rooms

 

 

5.11.1.

 

The shower rooms are inaccessible because there is insufficient turning space provided within the room.

 

TR21

 

30 months

5.11.2.

 

The transfer showers are inaccessible because they are 45 inches wide, the clear floor space does not extend beyond the rear of the seat, the seat is not on the wall opposite the controls, the seat is too long and too wide, and the controls are mounted on the wrong wall.

 

B2

 

30 months

5.12.

 

Medical Unit Shower Room with Toilet

 

 

5.12.1.

 

The route into the room is inaccessible because it is only 31 inches wide.

 

AR3

 

30months

5.12.2.

 

The shower contains a number of inaccessible elements and is not accessible to people with disabilities

 

B2

 

30 months

5.12.3.

 

No accessible mirror has been provided.

 

TR5

 

30 months

5.12.4.

 

The toilet is inaccessible because the centerline is much more than 18 inches from the side wall.

 

TR7

 

30 months

5.12.5.

 

The toilet is inaccessible because the rear grab bar is 19 inches long.

 

TR14

 

30 months

5.12.6.

 

The toilet is inaccessible because the side grab bar is 30 inches long.

 

TR17

 

30 months

5.12.7.

 

The toilet is inaccessible because the side grab bar is not mounted on the wall.

 

TR20

 

30 months

5.13.

 

Cells

 

 

5.13.1.

 

There are no accessible cells provided in any of the classification levels

 

PJ1

 

30 months

5.13.2.

 

There are no cells provided with communication features.

 

PJ2

 

30 months

5.14.

 

Rec Yard: The doors to the Rec Yard are inaccessible because the knob hardware requires tight grasping, pinching, or twisting of the wrist to operate.

 

D2

 

30 months

6.

 

Community Supervision and Corrections Department, located at 1901 Trojan Drive, Corpus Christi

 

 

6.1.

 

Parking

 

 

6.1.1.

 

The designated accessible parking spaces are inaccessible because the access aisles are not marked and one of the access aisles has a slope of 3.5%.

 

P2

 

24 months

6.1.2.

 

The designated accessible parking spaces are inaccessible because the vertical signs are mounted 51 inches high.

 

P3

 

24 months

6.1.3.

 

The parking lot is inaccessible because it has no van accessible parking space.

 

P5

 

24 month

6.2.

 

Entrance Ramp

 

 

6.2.1.

 

The ramp is inaccessible because it does not have edge protection.

 

R3

 

24 months

6.2.2.

 

The ramp is inaccessible because the inside handrail is 31 inches high.

 

R2

 

24 months

6.3.

 

Interior Doors: The doors throughout the facility are inaccessible because the knob hardware requires tight grasping, pinching, or twisting of the wrist to operate.

 

D2

 

24 months

6.4.

 

Interior Signage: The signage provided throughout the facility is inaccessible because it is mounted above the doors and does not have raised and Braille characters.

 

D15

 

24 months

6.5.

 

Main Lobby Counter

 

 

6.5.1.

 

The counter is inaccessible because it is 42 inches high.

 

C1

 

24 months

6.5.2.

 

This area is inaccessible because the counter protrudes into the walkway and is not detectable to blind persons using a cane.

 

AR7

 

24 months

6.6.

 

Security Check at Entrance: The counter is inaccessible because it is 44 inches high.

 

C1

 

24 months

6.7.

 

Cash Payments Counter: The counter is inaccessible because it is 42 inches high.

 

C1

 

24 months

6.8.

 

Women's Toilet Room with Stalls near Urinalysis Lab

 

 

6.8.1.

 

The pull side of the door is inaccessible because it has no clear space on the latch side.

 

D5

 

24 months

6.8.2.

 

The door is inaccessible because it requires 11 pounds of force to open.

 

D3

 

24 months

6.8.3.

 

The toilet room is inaccessible because there is insufficient turning space provided within the room.

 

TR21

 

24 months

6.8.4.

 

The lavatory is inaccessible because the water supply and drain pipes are not insulated or otherwise configured to protect against contact.

 

LS2

 

24 months

6.8.5.

 

The toilet room is inaccessible because there is no standard accessible toilet compartment provided.

 

TR2

 

24 months

6.9.

 

Men's Toilet Room with Stalls near Urinalysis Lab

 

 

6.9.1.

 

The pull side of the door is inaccessible because it has no clear space on the latch side.

 

D5

 

24 months

6.9.2.

 

The door is inaccessible because it requires 15 pounds of force to open.

 

D3

 

24 months

6.9.3.

 

The toilet room is inaccessible because, although the facility contains a fire alarm system, there are no visible alarms provided in the toilet room.

 

AL1

 

24 months

6.9.4.

 

The toilet room is inaccessible because there is insufficient turning space provided within the room.

 

TR21

 

24months

6.9.5.

 

The lavatory is inaccessible because the water supply and drain pipes are not insulated or otherwise configured to protect against contact.

 

LS2

 

24 months

6.9.6.

 

The soap dispenser is inaccessible because it is mounted 50 inches high behind the lavatory.

 

CT3

 

24 months

6.9.7.

 

The toilet room is inaccessible because there is no standard accessible toilet compartment provided.

 

TR2

 

24 months

6.10.

 

Drinking Fountain near Urinalysis Lab

 

 

6.10.1.

 

This area is inaccessible because the drinking fountain protrudes into the walkway and is not detectable to blind persons using a cane.

 

AR7

 

24 months

6.10.2.

 

Although a designated accessible drinking fountain is provided, there is no drinking fountain provided for people who have difficulty bending or stooping.

 

DF3

 

24 months

6.11.

 

Unisex Single-User Toilet Room near Secretary's Desk: Although this toilet room is inaccessible, there is no signage directing people with disabilities to the accessible toilet rooms.

 

TR10

 

24 months

7.

 

Bill Bode County Building, located at 11408 Leopard Street, Corpus Christi

 

 

7.1.

 

Parking: The parking lot is inaccessible because it has no van accessible parking space.

 

P5

 

24 months

7.2.

 

Exterior Route: The route from parking to the entrance is inaccessible because it is only 30 inches wide past the bushes.

 

AR3

 

24 months

7.3.

 

Reception Counter: The counter is inaccessible because it is 41 1/2 inches high.

 

C1

 

24 months

7.4.

 

Constable's Office Counter: The counter is inaccessible because it is 41 1/2 inches high.

 

C1

 

24 months

7.5.

 

Justice of the Peace Courtroom: The courtroom is inaccessible because there is no assistive listening system provided. This courtroom requires three receivers.

 

AA4

 

24 months

7.6.

 

Reception Area Drinking Fountain: Although a designated accessible drinking fountain is provided, there is no drinking fountain provided for people who have difficulty bending or stooping

 

DF3

 

24 months

7.7.

 

Reception Area Women's Toilet Room with Stalls

 

 

7.7.1.

 

The coat hook is inaccessible because it is mounted 67 inches high.

 

TR3

 

24 months

7.7.2.

 

The toilet compartment is inaccessible because the door is not self closing.

 

TR25

 

24 months

7.7.3.

 

The toilet is inaccessible because the rear grab bar is mounted with the close end 11 inches from the toilet centerline.

 

TR17

 

24 months

7.8.

 

Reception Area Men's Toilet Room with Stalls

 

 

7.8.1.

 

The coat hook is inaccessible because it is mounted 67 inches high.

 

TR3

 

24 months

7.8.2.

 

The toilet compartment is inaccessible because the door is not self closing.

 

TR25

 

24 months

8.

 

Hilltop Community Center, located at 11425 Leopard Street, Corpus Christi

 

 

8.1.

 

Route Outside Blue Room: This area is inaccessible because the Automated External Defibrillator protrudes into the walkway and is not detectable to blind persons using a cane.

 

AR7

 

24 months

8.2.

 

Interior Doors: The doors throughout the facility are inaccessible because they require more than 5 pounds of force to open.

 

D3

 

24 months

8.3.

 

Drinking Fountains: Although designated accessible drinking fountains are provided, there is no drinking fountain provided for people who have difficulty bending or stooping.

 

DF3

 

24 months

8.4.

 

Toilet Rooms: The toilet rooms throughout the facility contain a number of inaccessible elements and are not accessible to people with disabilities.

 

TR1

 

24 months

8.5.

 

C Wing Drinking Fountain

 

 

8.5.1.

 

The drinking fountain is inaccessible because the flow of water is 3 inches high.

 

DF5

 

24 months

8.5.2.

 

This area is inaccessible because the drinking fountain protrudes into the walkway and is not detectable to blind persons using a cane.

 

AR7

 

24 months

8.6.

 

A Wing Entrance: This entrance is inaccessible because the Exit sign protrudes into the walkway and is not detectable to blind persons using a cane.

 

AR7

 

24 months

8.7.

 

Exterior Routes: The routes between amenities, including grills, tables, and the playground, are inaccessible because the grass surface is not firm, stable, and slip resistant.

 

AR1

 

24 months

Return to Settlement