Please Note: Paragraph 54 of the Settlement Agreement requires that within three months of the effective date of this Agreement, the County provide signage as necessary to comply with 28 C.F.R. § 35.163(b), after having surveyed all facilities that are the subject of this Agreement for the purpose of identifying those that have multiple entrances not all of which are accessible.
The chart below lists the facilities surveyed by the Department, the access issues identified during the survey, and the actions required to correct the access issues. Required actions are listed using an alphanumeric code. The key to the alphanumeric codes is provided in Attachment M to this Agreement.
In order to ensure that the following spaces and elements in County facilities for which construction was commenced after January 26, 1992, are readily accessible to and usable by persons with disabilities, the County will take the actions referenced by the alphanumeric code and described in detail in Attachment M to this Settlement Agreement within the time periods specified below, which time periods will begin to run on the effective date of this Agreement.
Item # | Access Issue | Required Action | Completion Date |
1. | Juvenile Detention Center, located at 2310 Gollihar, Corpus Christi | ||
1.1. | South Parking Lot | ||
1.1.1. | The parking lot is inaccessible because it has no van accessible parking space. | P5 | 12 months |
1.1.2. | The designated accessible parking spaces are inaccessible because the vertical signs are mounted between 52 and 56 inches high. | P3 | 12 months |
1.2. | West Parking Lot | ||
1.2.1. | The designated accessible parking spaces are inaccessible because the access aisle is 37 inches wide. | P6 | 12 months |
1.2.2. | The designated accessible parking spaces are inaccessible because the access aisle is obstructed by the curb ramp, and the curb ramp is inaccessible because it has a slope of 10.1%. | AR4 | 12 months |
1.2.3. | The designated accessible parking spaces are inaccessible because the vertical signs are mounted between 52 and 56 inches high. | P3 | 12 months |
1.3. | Entrances: The building is inaccessible because it does not have directional signage posted at inaccessible entrances and does not have the International Symbol of Accessibility posted at accessible entrances. | D10 | 24 months |
1.4. | Interior Doors (Existing Wing) | ||
1.4.1. | The doors throughout this wing are inaccessible because the knob hardware requires tight grasping, pinching, or twisting of the wrist to operate. | D2 | 24 months |
1.4.2. | The doors to Rooms 118 and 123 are inaccessible because they have opening widths of 29 inches. | D14 | 24 months |
1.5. | Administration Wing Men's Toilet Rooms with Stalls: The door is inaccessible because it requires 17 pounds of force to open. | D3 | 24 months |
1.6. | Administration Wing Women's Toilet Rooms with Stalls: The toilet compartment is inaccessible because the door does not provide adequate toe clearance, and it is not self-closing. | TR23 | 24 months |
1.7. | Testing Men's Single-User Toilet Room | ||
1.7.1. | The door is inaccessible because it requires 17 pounds of force to open. | D3 | 24 months |
1.7.2. | The lavatory is inaccessible because the water supply and drain pipes are not insulated or otherwise configured to protect against contact. | LS2 | 24 months |
1.8. | Detention Administration Men's Toilet Rooms with Stalls | ||
1.8.1. | The toilet room is inaccessible because the sign has no raised or Braille characters. | TR11 | 24 months |
1.8.2. | The door is inaccessible because the knob hardware requires tight grasping, pinching, or twisting of the wrist to operate. | D2 | 24 months |
1.8.3. | The coat hook in the designated accessible stall is inaccessible because it is mounted 65 inches high. | TR3 | 24 months |
1.9. | Detention Administration Women's Toilet Rooms with Stalls | ||
1.9.1. | The toilet room is inaccessible because the sign has no raised or Braille characters. | TR11 | 24 months |
1.9.2. | The door is inaccessible because the knob hardware requires tight grasping, pinching, or twisting of the wrist to operate. | D2 | 24 months |
1.9.3. | The coat hook in the designated accessible stall is inaccessible because it is mounted 65 inches high. | TR3 | 24 months |
1.9.4. | The toilet is inaccessible because the flush control is on the closed side. | TR4 | 24 months |
1.10. | Intake Area Single-User Unisex Toilet Rooms | ||
1.10.1 | Both toilet rooms contain a number of inaccessible elements and are not accessible to people with disabilities. | TR1 | 30 months |
1.10.2. | The shower provided in one toilet room contains a number of inaccessible elements and is not accessible to people with disabilities. | B2 | 30 months |
1.11. | Juvenile Justice Control Room | ||
1.11.1. | The route into the control room is inaccessible because it requires traversing stairs. | AR2 | 24 months |
1.11.2. | The signage provided is inaccessible because it does not have raised and Braille characters. | D15 | 24 months |
1.12. | New Detention Wing Men's Toilet Room with Stalls: The toilet room is inaccessible because there is no standard accessible toilet compartment provided. | TR2 | 30 months |
1.13. | New Detention Wing Gym: The door is inaccessible because the knob hardware requires tight grasping, pinching, or twisting of the wrist to operate. | D2 | 30 months |
1.14. | New Detention Wing Staff Single-User Unisex Toilet Room | ||
1.14.1. | The toilet room is inaccessible because the sign has no raised or Braille characters. | TR11 | 24 months |
1.14.2. | The door is inaccessible because the knob hardware requires tight grasping, pinching, or twisting of the wrist to operate. | D2 | 24 months |
1.14.3. | The facility is inaccessible because, although the facility contains a fire alarm system, there are no visible alarms provided in the toilet room. | AL1 | 24 months |
1.14.4. | The door is inaccessible because the knob hardware requires tight grasping, pinching, or twisting of the wrist to operate. | D2 | 24 months |
1.14.5. | No accessible mirror has been provided. | TR5 | 24 months |
1.14.6. | The lavatory is inaccessible because it lacks adequate knee clearances. | LS3 | 24 months |
1.14.7. | The toilet paper dispenser is inaccessible because it is mounted behind the toilet. | TR6 | 24 months |
1.15. | New Detention Wing Gym Kids Single-User Toilet Room | ||
1.15.1. | The toilet room is inaccessible because the sign has no raised or Braille characters. | TR11 | 24 months |
1.15.2. | The door is inaccessible because the knob hardware requires tight grasping, pinching, or twisting of the wrist to operate. | D2 | 24 months |
1.15.3. | The facility is inaccessible because, although the facility contains a fire alarm system, there are no visible alarms provided in the toilet room. | AL1 | 24 months |
1.15.4. | No accessible mirror has been provided. | TR5 | 24 months |
1.15.5. | The lavatory is inaccessible because it lacks adequate knee clearances. | LS3 | 24 months |
1.15.6. | The toilet paper dispenser is inaccessible because it is mounted behind the toilet. | TR6 | 24 months |
1.15.7. | The toilet is inaccessible because there are no grab bars provided. | TR18 | 24 months |
1.16. | Post Adjudication Men's Single-User Toilet Room | ||
1.16.1. | The lavatory is inaccessible because the top of the lavatory rim is 36 inches high. | LS3 | 24 months |
1.16.2. | The lavatory is inaccessible because the water supply and drain pipes are not insulated or otherwise configured to protect against contact. | LS2 | 24 months |
1.16.3. | The toilet room is inaccessible because the trash receptacle protrudes into the walkway and is not detectable to blind persons using a cane. | AR7 | 24 months |
1.17. | Post Adjudication Women's Single-User Toilet Room | ||
1.17.1. | The pull side of the door is inaccessible because it has only 6 inches of clear space on the latch side. | D5 | 24 months |
1.17.2. | The lavatory is inaccessible because the top of the lavatory rim is 36 inches high. | LS3 | 24 months |
1.17.3. | The lavatory is inaccessible because the water supply and drain pipes are not insulated or otherwise configured to protect against contact. | LS2 | 24 months |
1.17.4. | The toilet room is inaccessible because the trash receptacle protrudes into the walkway and is not detectable to blind persons using a cane. | AR7 | 24 months |
1.17.5. | The soap dispenser is inaccessible because it is mounted 53 1/2 inches high behind the lavatory. | CT3 | 24 months |
1.8. | Post Adjudication Reception Area Men's Toilet Room with Stalls | ||
1.18.1. | The coat hook is inaccessible because it is mounted 64 inches high. | TR3 | 24 months |
1.18.2. | The air dryer is inaccessible because it is mounted with the controls 56 inches high. | CT4 | 24 months |
1.18.3. | The toilet room is inaccessible because the air dryer protrudes into the walkway and is not detectable to blind persons using a cane. | AR7 | 24 months |
1.19. | Post Adjudication Reception Area Women's Toilet Room with Stalls | ||
1.19.1. | The door is inaccessible because it requires 8 pounds of force to open. | D3 | 24 months |
1.19.2. | The air dryer is inaccessible because it is mounted with the controls 56 inches high. | CT4 | 24 months |
1.19.3. | The toilet room is inaccessible because the air dryer protrudes into the walkway and is not detectable to blind persons using a cane. | AR7 | 24 months |
1.19.4. | The coat hook is inaccessible because it is mounted 66 1/2 inches high. | TR3 | 24 months |
1.20. | Pods A and B Men's Shower Room: The shower room contains a number of inaccessible elements and is not accessible to people with disabilities. | LR1 | 30 months |
1.21. | Pod C Women's Shower Room: The shower room contains a number of inaccessible elements and is not accessible to people with disabilities. | LR1 | 30 months |
1.22. | Pod 4C Women's Single-User Toilet Room | ||
1.22.1. | The lavatory is inaccessible because the top of the lavatory rim is 36 inches high. | LS3 | 24 months |
1.22.2. | No accessible mirror has been provided. | TR5 | 24 months |
1.23. | Pod 4C Staff Single-User Toilet Room | ||
1.23.1. | The door is inaccessible because it requires 8 pounds of force to open. | D3 | 24 months |
1.23.2. | No accessible mirror has been provided. | TR5 | 24 months |
1.23.3. | The lavatory is inaccessible because the top of the lavatory rim is 36 inches high. | LS3 | 24 months |
1.24. | Post Adjudication Single-User Unisex Toilet Room | ||
1.24.1. | The door is inaccessible because it requires 8 pounds of force to open. | D3 | 24 months |
1.24.2. | No accessible mirror has been provided. | TR5 | 24 months |
1.25. | Courtroom | ||
1.25.1. | The witness stand is inaccessible because it can be accessed only by steps. | AR2 | 30 months |
1.25.2. | The courtroom is inaccessible because there is no assistive listening system provided. | AA4 | 18 months |
2. | Keach Family Library, located at 1000 Terrie Shamsie, Corpus Christi | ||
2.1. | Pay Phone: The telephone in the entry vestibule is inaccessible because it is mounted behind the bench and has no clear floor space. | TT1 | 9 months |
2.2. | Multi-Purpose Room Men's Toilet Room: The toilet is inaccessible because the rear grab bar is mounted with the near end less than 12 inches from the center of the toilet. | TR14 | 9 months |
3. | Banquete Community Center, located at 4359 4th Street, Banquete | ||
3.1. | Parking: The parking lot, with a total of 16 parking spaces, is inaccessible because two of the designated accessible parking spaces and access aisles are too narrow, and the third set is not on the shortest accessible route to an accessible entrance. This lot requires one van accessible space. | P1 | 18 months |
3.2. | Entrance: The building is inaccessible because it does not have directional signage posted at inaccessible entrances and does not have the International Symbol of Accessibility posted at accessible entrances. | D10 | 18 months |
3.3. | Interior Route: The area near the drinking fountains and toilet rooms is inaccessible because the defibrillator protrudes into the walkway and is not detectable to blind persons using a cane. | AR7 | 18 months |
3.4. | Men's Toilet Room with Stalls | ||
3.4.1. | The door is inaccessible because it has an opening width of 30 inches. | D14 | 24 months |
3.4.2. | The door is inaccessible because it requires 11 pounds of force to open. | D3 | 18 months |
3.4.3. | The facility is inaccessible because, although the facility contains a fire alarm system, there are no visible alarms provided in the toilet room. | AL1 | 24 months |
3.4.4. | The toilet room is inaccessible because the paper towel dispenser protrudes into the walkway and is not detectable to blind persons using a cane. | AR7 | 18 months |
3.4.5. | The lavatory is inaccessible because the hardware requires twisting of the wrist to operate. | LS4 | 18 months |
3.4.6. | The toilet paper dispenser is inaccessible because it is mounted 13 inches from the front of the toilet. | TR6 | 18 months |
3.5. | Women's Toilet Room with Stalls | ||
3.5.1. | The door is inaccessible because it has an opening width of 30 inches. | D14 | 24 months |
3.5.2. | The door is inaccessible because it requires 13 pounds of force to open. | D3 | 18 months |
3.5.3. | The facility is inaccessible because, although the facility contains a fire alarm system, there are no visible alarms provided in the toilet room. | AL1 | 18 months |
3.5.4. | The paper towel dispenser is inaccessible because it is mounted with the controls 57 inches high. | CT4 | 18 months |
3.5.5. | The toilet room is inaccessible because the paper towel dispenser protrudes into the walkway and is not detectable to blind persons using a cane. | AR7 | 18 months |
3.5.6. | The lavatory is inaccessible because the hardware requires twisting of the wrist to operate. | LS4 | 18 months |
3.5.7. | The toilet paper dispenser is inaccessible because it is mounted 14 inches from the front of the toilet. | TR6 | 18 months |
4. | Borchard Baseball Stadium, 1511 Main Street, Robstown | ||
4.1. | Parking | ||
4.1.1. | The parking lot is inaccessible because it has no designated van accessible parking spaces. | P5 | 30 months |
4.1.2. | Some of the designated accessible parking spaces are inaccessible because the vertical signs are mounted 54 inches high. | P3 | 30 months |
4.2. | Press Box Single-User Unisex Toilet Room | ||
4.2.1. | The toilet room is inaccessible because the paper towel dispenser protrudes into the walkway and is not detectable to blind persons using a cane. | AR7 | 30 months |
4.2.2. | The paper towel dispenser is inaccessible because the controls require twisting of the wrist to operate. | CT2 | 30 months |
4.3. | Left Field Route: This area is inaccessible because the drinking fountain protrudes into the walkway and is not detectable to blind persons using a cane. | AR7 | 30 months |
4.4. | Left Field Women's Toilet Room with Stalls | ||
4.4.1. | The paper towel dispenser is inaccessible because it is mounted with the controls 58 inches high. | CT4 | 30 months |
4.4.2. | The paper towel dispenser is inaccessible because the controls require twisting of the wrist to operate. | CT2 | 30 months |
4.4.3. | The toilet room is inaccessible because, although there are 16 stalls provided, the ambulatory stall was locked and could not be accessed. | TR22 | 30 months |
4.5. | Left Field Men's Toilet Room with Stalls | ||
4.5.1. | The paper towel dispenser is inaccessible because it is mounted with the controls 58 inches high. | CT4 | 30 months |
4.5.2. | The paper towel dispenser is inaccessible because the controls require twisting of the wrist to operate. | CT2 | 30 months |
4.5.3. | The toilet room is inaccessible because the paper towel dispenser protrudes into the walkway and is not detectable to blind persons using a cane. | AR7 | 30 months |
4.5.4. | The coat hook in the ambulatory stall is inaccessible because it is mounted 68 inches high. | TR3 | 30 months |
4.6. | Home Plate Single-User Unisex Toilet Room | ||
4.6.1. | The paper towel dispenser is inaccessible because the controls require twisting of the wrist to operate. | CT2 | 30 months |
4.6.2. | The toilet room is inaccessible because the paper towel dispenser protrudes into the walkway and is not detectable to blind persons using a cane. | AR7 | 30 months |
4.7. | Right Field Men's Toilet Room with Stalls | ||
4.7.1. | The paper towel dispenser is inaccessible because it is mounted with the controls 58 inches high. | CT4 | 30 months |
4.7.2. | The paper towel dispenser is inaccessible because the controls require twisting of the wrist to operate. | CT2 | 30 months |
4.7.3. | The toilet room is inaccessible because the paper towel dispenser protrudes into the walkway and is not detectable to blind persons using a cane. | AR7 | 30 months |
4.7.4. | The coat hook in the ambulatory stall is inaccessible because it is mounted 68 inches high. | TR3 | 30 months |
4.8. | Right Field Women's Toilet Room with Stalls | ||
4.8.1. | The paper towel dispenser is inaccessible because it is mounted with the controls 58 inches high. | CT4 | 30 months |
4.8.2. | The paper towel dispenser is inaccessible because the controls require twisting of the wrist to operate. | CT2 | 30 months |
4.9. | Right Field Route: This area is inaccessible because the drinking fountain protrudes into the walkway and is not detectable to blind persons using a cane. | AR7 | 30 months |
4.10. | Home Team Locker Room | ||
4.10.1. | There is no accessible shower provided. | B2 | 30 months |
4.10.2. | The paper towel dispenser in the toilet room is inaccessible because it is mounted with the controls 59 inches high. | CT4 | 30 months |
4.10.3. | The paper towel dispenser is inaccessible because the controls require twisting of the wrist to operate. | CT2 | 30 months |
4.10.4. | The toilet room is inaccessible because the paper towel dispenser protrudes into the walkway and is not detectable to blind persons using a cane. | AR7 | 30 months |
4.10.5. | There is no accessible locker provided. | LR3 | 30 months |
4.11. | Visitors' Locker Room | ||
4.11.1. | There is no accessible shower provided. | B2 | 30 months |
4.11.2. | The paper towel dispenser in the toilet room is inaccessible because it is mounted with the controls 59 inches high. | CT4 | 30 months |
4.11.3. | The paper towel dispenser is inaccessible because the controls require twisting of the wrist to operate. | CT2 | 30 months |
4.11.4. | There is no accessible locker provided. | LR3 | 30 months |
4.12. | Dugouts | ||
4.12.1. | The routes into the dugouts are inaccessible because they require traversing stairs. | AR2 | 30 months |
4.12.2. | The dugout toilet rooms contain a number of inaccessible elements and are not accessible to people with disabilities. | TR1 | 30 months |
5. | Borchard Regional Fairgrounds, located at 1100 Terry Shamisie, Robstown | ||
5.1. | Locker Rooms: The benches in locker rooms throughout the facility are inaccessible because they are less than 42 inches long. | LR2 | 24 months |
5.2. | Drinking Fountains: Routes throughout the fairgrounds are inaccessible because the drinking fountains protrude into the walkway and are not detectable to blind persons using a cane. | AR7 | 18 months |
5.3. | Toilet Rooms: The toilet rooms throughout the fairgrounds are inaccessible because the paper towel dispensers protrude into the walkway and are not detectable to blind persons using a cane. | AR7 | 18 months |
5.4. | Ballroom B Single-User Unisex Toilet Room: The paper towel dispenser is inaccessible because the controls require twisting of the wrist to operate. | CT2 | 18 months |
5.5. | Ballroom B Women's Toilet Room: The toilet room is inaccessible because, although there are 9 stalls provided, there is no ambulatory stall provided. | TR22 | 24 months |
5.6. | Ballroom B Men's Toilet Room: The urinal is inaccessible because the rim is 18 inches high. | TR8 | 18 months |
5.7. | West Central Pavilion Arena Men's Toilet Room with Stalls: The lower urinal is inaccessible because the rim is 18 inches high. | TR8 | 18 months |
5.8. | East Central Pavilion Arena Men's Toilet Room with Stalls: The lower urinal is inaccessible because the rim is 18 inches high. | TR8 | 18 months |
5.9. | Central Pavilion Arena Locker Room A: The roll-in shower is inaccessible because it lacks accessible grab bars. | B5 | 18 months |
5.10. | Equestrian Arena: The arena, containing 1000 bleacher seats, is inaccessible because there are only 6 wheelchair spaces provided. A total of 10 wheelchair spaces are required. | AA6 | 18 months |
6. | Medical Examiner's Office, located at 2610 Hospital Boulevard, Corpus Christi | ||
6.1. | Parking: The parking lot, with space for approximately 25 parking spaces, does not demarcate the designated accessible space or access aisle, and the signage is mounted too low. This lot requires one van accessible space, and may also require one standard accessible space (if there are more than 25 spaces). | P1 | 24 months |
6.2. | Route from Parking to Entrance: The route is inaccessible because it has a slope of 12.1% leading to the entrance door. | AR1 | 24 months |
6.3. | Route to Employee Area: This area is inaccessible because the drinking fountain protrudes into the walkway and is not detectable to blind persons using a cane. | AR7 | 24 months |
6.4. | Women's Single-User Toilet Room by Front Employee Offices | ||
6.4.1. | The toilet is inaccessible because the flush control is on the closed side. | TR4 | 18 months |
6.4.2. | The toilet is inaccessible because the clear floor space is obstructed by the storage unit. | TR24 | 18 months |
6.4.3. | The coat hook is inaccessible because it is mounted 69 inches high. | TR3 | 18 months |
6.5. | Men's Single-User Toilet Room by Front Employee Offices | ||
6.5.1. | The toilet is inaccessible because the clear floor space is obstructed by the storage unit. | TR24 | 18 months |
6.5.2. | The coat hook is inaccessible because it is mounted 70 inches high. | TR3 | 18 months |
6.6. | Conference Room: The computer table is inaccessible because it provides only 25 inches of clear knee height. | DW1 | 18 months |
6.7. | Single-User Unisex Toilet and Shower Room by Autopsy Room: The toilet room contains a number of inaccessible elements and is not accessible to people with disabilities. |
TR1 B2 |
24 months |
7. | Bishop Community Center, located at 201 W. Joyce Avenue, Bishop | ||
7.1. | Parking: The designated accessible parking spaces are inaccessible because the vertical signs are mounted too low, and there is no designated van accessible parking space. | P3 | 18 months |
7.2. | Men's Toilet Room with Stalls | ||
7.2.1. | The door is inaccessible because it cannot be opened 90 degrees due to the placement of the scale. | D14 | 18 months |
7.2.2. | The lavatory is inaccessible because the water supply and drain pipes are not insulated or otherwise configured to protect against contact. | LS2 | 18 months |
7.2.3. | The urinal is inaccessible because the clear floor space is only 23 inches wide. | TR8 | 18 months |
7.2.4. | The toilet is inaccessible because the side grab bar is obstructed by the toilet paper dispenser. | TR15 | 18 months |
7.2.5. | The toilet is inaccessible because the side grab bar is mounted with the far end 48 inches from the rear wall. | TR17 |
18 months |
7.3. | Women's Toilet Room with Stalls | ||
7.3.1. | The lavatory is inaccessible because the water supply and drain pipes are not insulated or otherwise configured to protect against contact. | LS2 | 18 months |
7.3.2. | The toilet is inaccessible because the side grab bar is obstructed by the toilet paper dispenser. | TR15 | 18 months |
7.3.3. | The toilet is inaccessible because the side grab bar is mounted with the far end 48 inches from the rear wall. | TR17 | 18 months |
7.3.4. | The toilet is inaccessible because the clear floor space is obstructed by the table in the stall. | TR24 | 6 months |
8. | Hazel Blakemore Park, located at 4343 CR 69, Corpus Christi | ||
8.1. | Exterior Routes: The routes from the parking lot to each of the park's amenities, including information kiosk, drinking fountain, toilet rooms, grills, picnic pavilion, picnic tables, benches, and playground, are inaccessible because the grass surface is not firm, stable, and slip resistant. | AR1 | 24 months |
8.2. | Men's Toilet Room with Stalls | ||
8.2.1. | The toilet room is inaccessible because the sign has no raised or Braille characters. | TR11 | 15 months |
8.2.2. | The coat hook is inaccessible because it is mounted 59 inches high. | TR3 | 15 months |
8.2.3. | The toilet is inaccessible because the top of the seat is 15 inches high. | TR9 | 5 months |
8.3. | Women's Toilet Room with Stalls | ||
8.3.1. | The toilet room is inaccessible because the sign has no raised or Braille characters. | TR11 | 15 months |
8.3.2. | The coat hook is inaccessible because it is mounted 59 inches high. | TR3 | 15 months |
8.3.3. | The toilet is inaccessible because the top of the seat is 15 inches high. | TR9 | 15 months |
9. | Justice of the Peace, Precinct 4, 705 West Avenue A, Port Aransas | ||
9.1. | Parking | ||
9.1.1. | The designated accessible parking spaces are inaccessible because they lack vertical signage. | P3 | 24 months |
9.1.2. | The parking lot is inaccessible because the curb ramp has a slope of 10.4%, the flared sides have slopes of 13.4% and 12.4%, and the curb ramp projects into the access aisle. | AR4 | 24 months |
9.1.3. | The parking lot is inaccessible because it has no van accessible parking space. | P5 | 24 months |
9.2. | Route from Parking to Constable's Office: The route is inaccessible because it is only 24 inches wide past the garbage enclosure. | AR3 | 24 months |
9.3. | Constable's Office Entrance | ||
9.3.1. | The push side of the door, which has a closer and a latch, is inaccessible because it has only 6 inches of clear space on the latch side. | D5 | 24 months |
9.3.2. | The door is inaccessible because it has a 1 1/2 inch high threshold. | D12 | 24 months |
9.4. | Constable's Office Patrol Room Single-User Unisex Toilet Room | ||
9.4.1. | The pull side of the door is inaccessible because it has only 5 inches of clear space on the latch side. | D5 | 24 months |
9.4.2. | The door is inaccessible because the knob hardware requires tight grasping, pinching, or twisting of the wrist to operate. | D2 | 24 months |
9.4.3. | The toilet is inaccessible because the flush control is on the closed side. | TR4 | 24 months |
9.4.4. | The coat hook is inaccessible because it is mounted 61 inches high. | TR3 | 24 months |
9.5. | Municipal Court Main Reception Counter | ||
9.5.1. | The door-mounted counter is inaccessible because it is 45 1/2 inches high. | C1 | 24 months |
9.5.2. | The office counter is inaccessible because it is 48 inches high. | C1 | 24 months |
9.6. | Drinking Fountain Outside Courtroom: The drinking fountain protrudes into the walkway and is not detectable to blind persons using a cane. | AR7 | 24 months |
9.7. | Women's Single-User Toilet Room Outside Courtroom | ||
9.7.1. | The push side of the door, which has both a closer and a latch, is inaccessible because it has only 2 inches of clear space on the latch side. | D5 | 24 months |
9.7.2. | The door is inaccessible because the knob hardware requires tight grasping, pinching, or twisting of the wrist to operate. | D2 | 24 months |
9.7.3. | The coat hook is inaccessible because it is mounted 61 inches high. | TR3 | 24 months |
9.8. | Men's Single-User Toilet Room Outside Courtroom | ||
9.8.1. | The push side of the door, which has both a closer and a latch, is inaccessible because it has only 6 inches of clear space on the latch side. | D5 | 24 months |
9.8.2. | The door is inaccessible because the knob hardware requires tight grasping, pinching, or twisting of the wrist to operate. | D2 | 24 months |
9.8.3. | The toilet is inaccessible because the flush control is on the closed side. | TR4 | 24 months |
9.8.4. | The coat hook is inaccessible because it is mounted 61 inches high. | TR3 | 24 months |
9.10. | Courtroom: The courtroom is inaccessible because there is no assistive listening system provided. This courtroom requires 2 receivers. | AA4 | 18 months |