ATTACHMENT I: Modifications to Newly Constructed Facilities

Please Note: Paragraph 54 of the Settlement Agreement requires that within three months of the effective date of this Agreement, the County provide signage as necessary to comply with 28 C.F.R. § 35.163(b), after having surveyed all facilities that are the subject of this Agreement for the purpose of identifying those that have multiple entrances not all of which are accessible.

The chart below lists the facilities surveyed by the Department, the access issues identified during the survey, and the actions required to correct the access issues. Required actions are listed using an alphanumeric code. The key to the alphanumeric codes is provided in Attachment M to this Agreement.

In order to ensure that the following spaces and elements in County facilities for which construction was commenced after January 26, 1992, are readily accessible to and usable by persons with disabilities, the County will take the actions referenced by the alphanumeric code and described in detail in Attachment M to this Settlement Agreement within the time periods specified below, which time periods will begin to run on the effective date of this Agreement.

Item # Access Issue Required Action Completion Date
1. Juvenile Detention Center, located at 2310 Gollihar, Corpus Christi
1.1. South Parking Lot
1.1.1. The parking lot is inaccessible because it has no van accessible parking space. P5 12 months
1.1.2. The designated accessible parking spaces are inaccessible because the vertical signs are mounted between 52 and 56 inches high. P3 12 months
1.2. West Parking Lot
1.2.1. The designated accessible parking spaces are inaccessible because the access aisle is 37 inches wide. P6 12 months
1.2.2. The designated accessible parking spaces are inaccessible because the access aisle is obstructed by the curb ramp, and the curb ramp is inaccessible because it has a slope of 10.1%. AR4 12 months
1.2.3. The designated accessible parking spaces are inaccessible because the vertical signs are mounted between 52 and 56 inches high. P3 12 months
1.3. Entrances: The building is inaccessible because it does not have directional signage posted at inaccessible entrances and does not have the International Symbol of Accessibility posted at accessible entrances. D10 24 months
1.4. Interior Doors (Existing Wing)
1.4.1. The doors throughout this wing are inaccessible because the knob hardware requires tight grasping, pinching, or twisting of the wrist to operate. D2 24 months
1.4.2. The doors to Rooms 118 and 123 are inaccessible because they have opening widths of 29 inches. D14 24 months
1.5. Administration Wing Men's Toilet Rooms with Stalls: The door is inaccessible because it requires 17 pounds of force to open. D3 24 months
1.6. Administration Wing Women's Toilet Rooms with Stalls: The toilet compartment is inaccessible because the door does not provide adequate toe clearance, and it is not self-closing. TR23 24 months
1.7. Testing Men's Single-User Toilet Room
1.7.1. The door is inaccessible because it requires 17 pounds of force to open. D3 24 months
1.7.2. The lavatory is inaccessible because the water supply and drain pipes are not insulated or otherwise configured to protect against contact. LS2 24 months
1.8. Detention Administration Men's Toilet Rooms with Stalls
1.8.1. The toilet room is inaccessible because the sign has no raised or Braille characters. TR11 24 months
1.8.2. The door is inaccessible because the knob hardware requires tight grasping, pinching, or twisting of the wrist to operate. D2 24 months
1.8.3. The coat hook in the designated accessible stall is inaccessible because it is mounted 65 inches high. TR3 24 months
1.9. Detention Administration Women's Toilet Rooms with Stalls
1.9.1. The toilet room is inaccessible because the sign has no raised or Braille characters. TR11 24 months
1.9.2. The door is inaccessible because the knob hardware requires tight grasping, pinching, or twisting of the wrist to operate. D2 24 months
1.9.3. The coat hook in the designated accessible stall is inaccessible because it is mounted 65 inches high. TR3 24 months
1.9.4. The toilet is inaccessible because the flush control is on the closed side. TR4 24 months
1.10. Intake Area Single-User Unisex Toilet Rooms
1.10.1 Both toilet rooms contain a number of inaccessible elements and are not accessible to people with disabilities. TR1 30 months
1.10.2. The shower provided in one toilet room contains a number of inaccessible elements and is not accessible to people with disabilities. B2 30 months
1.11. Juvenile Justice Control Room
1.11.1. The route into the control room is inaccessible because it requires traversing stairs. AR2 24 months
1.11.2. The signage provided is inaccessible because it does not have raised and Braille characters. D15 24 months
1.12. New Detention Wing Men's Toilet Room with Stalls: The toilet room is inaccessible because there is no standard accessible toilet compartment provided. TR2 30 months
1.13. New Detention Wing Gym: The door is inaccessible because the knob hardware requires tight grasping, pinching, or twisting of the wrist to operate. D2 30 months
1.14. New Detention Wing Staff Single-User Unisex Toilet Room
1.14.1. The toilet room is inaccessible because the sign has no raised or Braille characters. TR11 24 months
1.14.2. The door is inaccessible because the knob hardware requires tight grasping, pinching, or twisting of the wrist to operate. D2 24 months
1.14.3. The facility is inaccessible because, although the facility contains a fire alarm system, there are no visible alarms provided in the toilet room. AL1 24 months
1.14.4. The door is inaccessible because the knob hardware requires tight grasping, pinching, or twisting of the wrist to operate. D2 24 months
1.14.5. No accessible mirror has been provided. TR5 24 months
1.14.6. The lavatory is inaccessible because it lacks adequate knee clearances. LS3 24 months
1.14.7. The toilet paper dispenser is inaccessible because it is mounted behind the toilet. TR6 24 months
1.15. New Detention Wing Gym Kids Single-User Toilet Room
1.15.1. The toilet room is inaccessible because the sign has no raised or Braille characters. TR11 24 months
1.15.2. The door is inaccessible because the knob hardware requires tight grasping, pinching, or twisting of the wrist to operate. D2 24 months
1.15.3. The facility is inaccessible because, although the facility contains a fire alarm system, there are no visible alarms provided in the toilet room. AL1 24 months
1.15.4. No accessible mirror has been provided. TR5 24 months
1.15.5. The lavatory is inaccessible because it lacks adequate knee clearances. LS3 24 months
1.15.6. The toilet paper dispenser is inaccessible because it is mounted behind the toilet. TR6 24 months
1.15.7. The toilet is inaccessible because there are no grab bars provided. TR18 24 months
1.16. Post Adjudication Men's Single-User Toilet Room
1.16.1. The lavatory is inaccessible because the top of the lavatory rim is 36 inches high. LS3 24 months
1.16.2. The lavatory is inaccessible because the water supply and drain pipes are not insulated or otherwise configured to protect against contact. LS2 24 months
1.16.3. The toilet room is inaccessible because the trash receptacle protrudes into the walkway and is not detectable to blind persons using a cane. AR7 24 months
1.17. Post Adjudication Women's Single-User Toilet Room
1.17.1. The pull side of the door is inaccessible because it has only 6 inches of clear space on the latch side. D5 24 months
1.17.2. The lavatory is inaccessible because the top of the lavatory rim is 36 inches high. LS3 24 months
1.17.3. The lavatory is inaccessible because the water supply and drain pipes are not insulated or otherwise configured to protect against contact. LS2 24 months
1.17.4. The toilet room is inaccessible because the trash receptacle protrudes into the walkway and is not detectable to blind persons using a cane. AR7 24 months
1.17.5. The soap dispenser is inaccessible because it is mounted 53 1/2 inches high behind the lavatory. CT3 24 months
1.8. Post Adjudication Reception Area Men's Toilet Room with Stalls
1.18.1. The coat hook is inaccessible because it is mounted 64 inches high. TR3 24 months
1.18.2. The air dryer is inaccessible because it is mounted with the controls 56 inches high. CT4 24 months
1.18.3. The toilet room is inaccessible because the air dryer protrudes into the walkway and is not detectable to blind persons using a cane. AR7 24 months
1.19. Post Adjudication Reception Area Women's Toilet Room with Stalls
1.19.1. The door is inaccessible because it requires 8 pounds of force to open. D3 24 months
1.19.2. The air dryer is inaccessible because it is mounted with the controls 56 inches high. CT4 24 months
1.19.3. The toilet room is inaccessible because the air dryer protrudes into the walkway and is not detectable to blind persons using a cane. AR7 24 months
1.19.4. The coat hook is inaccessible because it is mounted 66 1/2 inches high. TR3 24 months
1.20. Pods A and B Men's Shower Room: The shower room contains a number of inaccessible elements and is not accessible to people with disabilities. LR1 30 months
1.21. Pod C Women's Shower Room: The shower room contains a number of inaccessible elements and is not accessible to people with disabilities. LR1 30 months
1.22. Pod 4C Women's Single-User Toilet Room
1.22.1. The lavatory is inaccessible because the top of the lavatory rim is 36 inches high. LS3 24 months
1.22.2. No accessible mirror has been provided. TR5 24 months
1.23. Pod 4C Staff Single-User Toilet Room
1.23.1. The door is inaccessible because it requires 8 pounds of force to open. D3 24 months
1.23.2. No accessible mirror has been provided. TR5 24 months
1.23.3. The lavatory is inaccessible because the top of the lavatory rim is 36 inches high. LS3 24 months
1.24. Post Adjudication Single-User Unisex Toilet Room
1.24.1. The door is inaccessible because it requires 8 pounds of force to open. D3 24 months
1.24.2. No accessible mirror has been provided. TR5 24 months
1.25. Courtroom
1.25.1. The witness stand is inaccessible because it can be accessed only by steps. AR2 30 months
1.25.2. The courtroom is inaccessible because there is no assistive listening system provided. AA4 18 months
2. Keach Family Library, located at 1000 Terrie Shamsie, Corpus Christi
2.1. Pay Phone: The telephone in the entry vestibule is inaccessible because it is mounted behind the bench and has no clear floor space. TT1 9 months
2.2. Multi-Purpose Room Men's Toilet Room: The toilet is inaccessible because the rear grab bar is mounted with the near end less than 12 inches from the center of the toilet. TR14 9 months
3. Banquete Community Center, located at 4359 4th Street, Banquete
3.1. Parking: The parking lot, with a total of 16 parking spaces, is inaccessible because two of the designated accessible parking spaces and access aisles are too narrow, and the third set is not on the shortest accessible route to an accessible entrance. This lot requires one van accessible space. P1 18 months
3.2. Entrance: The building is inaccessible because it does not have directional signage posted at inaccessible entrances and does not have the International Symbol of Accessibility posted at accessible entrances. D10 18 months
3.3. Interior Route: The area near the drinking fountains and toilet rooms is inaccessible because the defibrillator protrudes into the walkway and is not detectable to blind persons using a cane. AR7 18 months
3.4. Men's Toilet Room with Stalls
3.4.1. The door is inaccessible because it has an opening width of 30 inches. D14 24 months
3.4.2. The door is inaccessible because it requires 11 pounds of force to open. D3 18 months
3.4.3. The facility is inaccessible because, although the facility contains a fire alarm system, there are no visible alarms provided in the toilet room. AL1 24 months
3.4.4. The toilet room is inaccessible because the paper towel dispenser protrudes into the walkway and is not detectable to blind persons using a cane. AR7 18 months
3.4.5. The lavatory is inaccessible because the hardware requires twisting of the wrist to operate. LS4 18 months
3.4.6. The toilet paper dispenser is inaccessible because it is mounted 13 inches from the front of the toilet. TR6 18 months
3.5. Women's Toilet Room with Stalls
3.5.1. The door is inaccessible because it has an opening width of 30 inches. D14 24 months
3.5.2. The door is inaccessible because it requires 13 pounds of force to open. D3 18 months
3.5.3. The facility is inaccessible because, although the facility contains a fire alarm system, there are no visible alarms provided in the toilet room. AL1 18 months
3.5.4. The paper towel dispenser is inaccessible because it is mounted with the controls 57 inches high. CT4 18 months
3.5.5. The toilet room is inaccessible because the paper towel dispenser protrudes into the walkway and is not detectable to blind persons using a cane. AR7 18 months
3.5.6. The lavatory is inaccessible because the hardware requires twisting of the wrist to operate. LS4 18 months
3.5.7. The toilet paper dispenser is inaccessible because it is mounted 14 inches from the front of the toilet. TR6 18 months
4. Borchard Baseball Stadium, 1511 Main Street, Robstown
4.1. Parking
4.1.1. The parking lot is inaccessible because it has no designated van accessible parking spaces. P5 30 months
4.1.2. Some of the designated accessible parking spaces are inaccessible because the vertical signs are mounted 54 inches high. P3 30 months
4.2. Press Box Single-User Unisex Toilet Room
4.2.1. The toilet room is inaccessible because the paper towel dispenser protrudes into the walkway and is not detectable to blind persons using a cane. AR7 30 months
4.2.2. The paper towel dispenser is inaccessible because the controls require twisting of the wrist to operate. CT2 30 months
4.3. Left Field Route: This area is inaccessible because the drinking fountain protrudes into the walkway and is not detectable to blind persons using a cane. AR7 30 months
4.4. Left Field Women's Toilet Room with Stalls
4.4.1. The paper towel dispenser is inaccessible because it is mounted with the controls 58 inches high. CT4 30 months
4.4.2. The paper towel dispenser is inaccessible because the controls require twisting of the wrist to operate. CT2 30 months
4.4.3. The toilet room is inaccessible because, although there are 16 stalls provided, the ambulatory stall was locked and could not be accessed. TR22 30 months
4.5. Left Field Men's Toilet Room with Stalls
4.5.1. The paper towel dispenser is inaccessible because it is mounted with the controls 58 inches high. CT4 30 months
4.5.2. The paper towel dispenser is inaccessible because the controls require twisting of the wrist to operate. CT2 30 months
4.5.3. The toilet room is inaccessible because the paper towel dispenser protrudes into the walkway and is not detectable to blind persons using a cane. AR7 30 months
4.5.4. The coat hook in the ambulatory stall is inaccessible because it is mounted 68 inches high. TR3 30 months
4.6. Home Plate Single-User Unisex Toilet Room
4.6.1. The paper towel dispenser is inaccessible because the controls require twisting of the wrist to operate. CT2 30 months
4.6.2. The toilet room is inaccessible because the paper towel dispenser protrudes into the walkway and is not detectable to blind persons using a cane. AR7 30 months
4.7. Right Field Men's Toilet Room with Stalls
4.7.1. The paper towel dispenser is inaccessible because it is mounted with the controls 58 inches high. CT4 30 months
4.7.2. The paper towel dispenser is inaccessible because the controls require twisting of the wrist to operate. CT2 30 months
4.7.3. The toilet room is inaccessible because the paper towel dispenser protrudes into the walkway and is not detectable to blind persons using a cane. AR7 30 months
4.7.4. The coat hook in the ambulatory stall is inaccessible because it is mounted 68 inches high. TR3 30 months
4.8. Right Field Women's Toilet Room with Stalls
4.8.1. The paper towel dispenser is inaccessible because it is mounted with the controls 58 inches high. CT4 30 months
4.8.2. The paper towel dispenser is inaccessible because the controls require twisting of the wrist to operate. CT2 30 months
4.9. Right Field Route: This area is inaccessible because the drinking fountain protrudes into the walkway and is not detectable to blind persons using a cane. AR7 30 months
4.10. Home Team Locker Room
4.10.1. There is no accessible shower provided. B2 30 months
4.10.2. The paper towel dispenser in the toilet room is inaccessible because it is mounted with the controls 59 inches high. CT4 30 months
4.10.3. The paper towel dispenser is inaccessible because the controls require twisting of the wrist to operate. CT2 30 months
4.10.4. The toilet room is inaccessible because the paper towel dispenser protrudes into the walkway and is not detectable to blind persons using a cane. AR7 30 months
4.10.5. There is no accessible locker provided. LR3 30 months
4.11. Visitors' Locker Room
4.11.1. There is no accessible shower provided. B2 30 months
4.11.2. The paper towel dispenser in the toilet room is inaccessible because it is mounted with the controls 59 inches high. CT4 30 months
4.11.3. The paper towel dispenser is inaccessible because the controls require twisting of the wrist to operate. CT2 30 months
4.11.4. There is no accessible locker provided. LR3 30 months
4.12. Dugouts
4.12.1. The routes into the dugouts are inaccessible because they require traversing stairs. AR2 30 months
4.12.2. The dugout toilet rooms contain a number of inaccessible elements and are not accessible to people with disabilities. TR1 30 months
5. Borchard Regional Fairgrounds, located at 1100 Terry Shamisie, Robstown
5.1. Locker Rooms: The benches in locker rooms throughout the facility are inaccessible because they are less than 42 inches long. LR2 24 months
5.2. Drinking Fountains: Routes throughout the fairgrounds are inaccessible because the drinking fountains protrude into the walkway and are not detectable to blind persons using a cane. AR7 18 months
5.3. Toilet Rooms: The toilet rooms throughout the fairgrounds are inaccessible because the paper towel dispensers protrude into the walkway and are not detectable to blind persons using a cane. AR7 18 months
5.4. Ballroom B Single-User Unisex Toilet Room:  The paper towel dispenser is inaccessible because the controls require twisting of the wrist to operate. CT2 18 months
5.5. Ballroom B Women's Toilet Room: The toilet room is inaccessible because, although there are 9 stalls provided, there is no ambulatory stall provided. TR22 24 months
5.6. Ballroom B Men's Toilet Room: The urinal is inaccessible because the rim is 18 inches high. TR8 18 months
5.7. West Central Pavilion Arena Men's Toilet Room with Stalls: The lower urinal is inaccessible because the rim is 18 inches high. TR8 18 months
5.8. East Central Pavilion Arena Men's Toilet Room with Stalls: The lower urinal is inaccessible because the rim is 18 inches high. TR8 18 months
5.9. Central Pavilion Arena Locker Room A: The roll-in shower is inaccessible because it lacks accessible grab bars. B5 18 months
5.10. Equestrian Arena: The arena, containing 1000 bleacher seats, is inaccessible because there are only 6 wheelchair spaces provided.  A total of 10 wheelchair spaces are required. AA6 18 months
6. Medical Examiner's Office, located at 2610 Hospital Boulevard, Corpus Christi
6.1. Parking: The parking lot, with space for approximately 25 parking spaces, does not demarcate the designated accessible space or access aisle, and the signage is mounted too low.  This lot requires one van accessible space, and may also require one standard accessible space (if there are more than 25 spaces). P1 24 months
6.2. Route from Parking to Entrance: The route is inaccessible because it has a slope of 12.1% leading to the entrance door. AR1 24 months
6.3. Route to Employee Area: This area is inaccessible because the drinking fountain protrudes into the walkway and is not detectable to blind persons using a cane. AR7 24 months
6.4. Women's Single-User Toilet Room by Front Employee Offices
6.4.1. The toilet is inaccessible because the flush control is on the closed side. TR4 18 months
6.4.2. The toilet is inaccessible because the clear floor space is obstructed by the storage unit. TR24 18 months
6.4.3. The coat hook is inaccessible because it is mounted 69 inches high. TR3 18 months
6.5. Men's Single-User Toilet Room by Front Employee Offices
6.5.1. The toilet is inaccessible because the clear floor space is obstructed by the storage unit. TR24 18 months
6.5.2. The coat hook is inaccessible because it is mounted 70 inches high. TR3 18 months
6.6. Conference Room: The computer table is inaccessible because it provides only 25 inches of clear knee height. DW1 18 months
6.7. Single-User Unisex Toilet and Shower Room by Autopsy Room: The toilet room contains a number of inaccessible elements and is not accessible to people with disabilities. TR1
B2
24 months
7. Bishop Community Center, located at 201 W. Joyce Avenue, Bishop
7.1. Parking: The designated accessible parking spaces are inaccessible because the vertical signs are mounted too low, and there is no designated van accessible parking space. P3 18 months
7.2. Men's Toilet Room with Stalls
7.2.1. The door is inaccessible because it cannot be opened 90 degrees due to the placement of the scale. D14 18 months
7.2.2. The lavatory is inaccessible because the water supply and drain pipes are not insulated or otherwise configured to protect against contact. LS2 18 months
7.2.3. The urinal is inaccessible because the clear floor space is only 23 inches wide. TR8 18 months
7.2.4. The toilet is inaccessible because the side grab bar is obstructed by the toilet paper dispenser. TR15 18 months
7.2.5. The toilet is inaccessible because the side grab bar is mounted with the far end 48 inches from the rear wall. TR17 18 months
7.3. Women's Toilet Room with Stalls
7.3.1. The lavatory is inaccessible because the water supply and drain pipes are not insulated or otherwise configured to protect against contact. LS2 18 months
7.3.2. The toilet is inaccessible because the side grab bar is obstructed by the toilet paper dispenser. TR15 18 months
7.3.3. The toilet is inaccessible because the side grab bar is mounted with the far end 48 inches from the rear wall. TR17 18 months 
7.3.4. The toilet is inaccessible because the clear floor space is obstructed by the table in the stall. TR24 6 months   
8. Hazel Blakemore Park, located at 4343 CR 69, Corpus Christi
8.1. Exterior Routes: The routes from the parking lot to each of the park's amenities, including information kiosk, drinking fountain, toilet rooms, grills, picnic pavilion, picnic tables, benches, and playground, are inaccessible because the grass surface is not firm, stable, and slip resistant. AR1 24 months
8.2. Men's Toilet Room with Stalls
8.2.1. The toilet room is inaccessible because the sign has no raised or Braille characters. TR11 15 months
8.2.2. The coat hook is inaccessible because it is mounted 59 inches high. TR3 15 months
8.2.3. The toilet is inaccessible because the top of the seat is 15 inches high. TR9 5 months
8.3. Women's Toilet Room with Stalls
8.3.1. The toilet room is inaccessible because the sign has no raised or Braille characters. TR11 15 months
8.3.2. The coat hook is inaccessible because it is mounted 59 inches high. TR3 15 months
8.3.3. The toilet is inaccessible because the top of the seat is 15 inches high. TR9 15 months 
9. Justice of the Peace, Precinct 4, 705 West Avenue A, Port Aransas    
9.1. Parking    
9.1.1. The designated accessible parking spaces are inaccessible because they lack vertical signage. P3 24 months
9.1.2. The parking lot is inaccessible because the curb ramp has a slope of 10.4%, the flared sides have slopes of 13.4% and 12.4%, and the curb ramp projects into the access aisle. AR4 24 months
9.1.3. The parking lot is inaccessible because it has no van accessible parking space. P5 24 months
9.2. Route from Parking to Constable's Office: The route is inaccessible because it is only 24 inches wide past the garbage enclosure. AR3 24 months
9.3. Constable's Office Entrance    
9.3.1. The push side of the door, which has a closer and a latch, is inaccessible because it has only 6 inches of clear space on the latch side. D5 24 months
9.3.2. The door is inaccessible because it has a 1 1/2 inch high threshold. D12 24 months
9.4. Constable's Office Patrol Room Single-User Unisex Toilet Room    
9.4.1. The pull side of the door is inaccessible because it has only 5 inches of clear space on the latch side. D5 24 months
9.4.2. The door is inaccessible because the knob hardware requires tight grasping, pinching, or twisting of the wrist to operate. D2 24 months
9.4.3. The toilet is inaccessible because the flush control is on the closed side. TR4 24 months
9.4.4. The coat hook is inaccessible because it is mounted 61 inches high. TR3 24 months
9.5. Municipal Court Main Reception Counter    
9.5.1. The door-mounted counter is inaccessible because it is 45 1/2 inches high. C1 24 months
9.5.2. The office counter is inaccessible because it is 48 inches high. C1 24 months
9.6. Drinking Fountain Outside Courtroom: The drinking fountain protrudes into the walkway and is not detectable to blind persons using a cane. AR7 24 months
9.7. Women's Single-User Toilet Room Outside Courtroom    
9.7.1. The push side of the door, which has both a closer and a latch, is inaccessible because it has only 2 inches of clear space on the latch side. D5 24 months
9.7.2. The door is inaccessible because the knob hardware requires tight grasping, pinching, or twisting of the wrist to operate. D2 24 months
9.7.3. The coat hook is inaccessible because it is mounted 61 inches high. TR3 24 months
9.8. Men's Single-User Toilet Room Outside Courtroom    
9.8.1. The push side of the door, which has both a closer and a latch, is inaccessible because it has only 6 inches of clear space on the latch side. D5 24 months
9.8.2. The door is inaccessible because the knob hardware requires tight grasping, pinching, or twisting of the wrist to operate. D2 24 months
9.8.3. The toilet is inaccessible because the flush control is on the closed side. TR4 24 months
9.8.4. The coat hook is inaccessible because it is mounted 61 inches high. TR3 24 months
9.10. Courtroom: The courtroom is inaccessible because there is no assistive listening system provided. This courtroom requires 2 receivers. AA4 18 months