ATTACHMENT K: Program Access in Existing FacilitiesPlease Note: Paragraph 20 of the Agreement requires that within nine (9) months of the effective date of this Agreement, the County will provide signage as necessary to comply with 28 C.F.R. §35.163(b), after having surveyed all facilities that are the subject of this Agreement for the purpose of identifying those that have multiple entrances not all of which are accessible. The technical requirements and, where appropriate, the scoping requirements of the Standards are used as a guide for determining whether a program or activity held in an existing facility is Areadily accessible to and usable by persons with disabilities and for determining what changes are necessary to make this program or activity accessible if it continues to be provided in the existing facility in question. See 28 C.F.R. §§35.150(b)(1), 35.151. The chart below lists the facilities surveyed by the Department, the access issues identified during the survey, and the actions required to correct the access issues. Required actions are listed using an alphanumeric code. The key to the alphanumeric codes is provided in Attachment M to this Agreement. In order to ensure that the programs, services, and activities housed in the County's facilities are accessible to persons with disabilities, when viewed in their entirety, the County will take the actions referenced by the alphanumeric code and described in detail in Attachment M to this Settlement Agreement within the time period specified below, which time period begins to run on the effective date of the Agreement. |
|||
Item # | Access Issue | Required Action | Completion Date |
---|---|---|---|
1. | County of Norfolk Administration Offices | ||
1.1. | Entrance | ||
1.1.1. | The door is inaccessible because there is a slope of 14.7% within the door's required maneuvering clearance. | D13 | 24 months |
1.1.2. | The interior door is inaccessible because it requires 14 pounds of force to open. | D2 | 24 months |
1.2. | Treasurer's Office. The door is inaccessible because it requires 13 pounds of force to open. | D2 | 24 months |
1.3. | Elevator | ||
1.3.1. | The elevator is inaccessible because the car control button for the main entry floor is not designated by a raised star. | E4 | 24 months |
1.3.2. | The elevator is inaccessible because the emergency system requires voice communication to operate. | E8 | 24 months |
1.4. | 2nd Floor Toilet Rooms with Stalls. The toilet rooms contain a number of inaccessible elements and are not accessible to people with disabilities. | TR22 | 24 months |
2. | Quincy District Courthouse | ||
2.1. | Parking. The parking lot, with a total of 135 parking spaces, is inaccessible because there are only 3 designated accessible parking spaces at the rear of the building, and there is no van accessible space. This lot requires 1 van accessible space and 4 standard accessible spaces. | P3 | 24 months |
2.2. | Telephones. Although there are more than 3 public pay telephones provided in the facility, a TTY is not provided. | TT2 | 24 months |
2.3. | Juvenile Court, Basement Level | ||
2.3.1. | The door is inaccessible because it requires 14 pounds of force to open. | D2 | 24 months |
2.3.2. | The door is inaccessible because knob hardware is used. | D1 | 24 months |
2.3.3. | The pull side of the door, which is accessed through a front approach, is inaccessible because it has only 6 inches of clear space on the latch side. | D6 | 24 months |
2.4. | 2nd Session Court, 2nd Floor | ||
2.4.1. | The witness stand is inaccessible because it can be accessed only by steps. | AA8 | 24 months |
2.4.2. | The door is inaccessible because it requires more than 5 pounds of force to open. | D2 | 24 months |
2.4.3. | There is no signage informing the public of the availability of an assistive listening system. | AA3 | 24 months |
2.4.4. | The counsel tables are inaccessible because they provide 24 inches of clear knee height. | T1 | 24 months |
2.4.5. | There is no signage informing the public of the availability of an assistive listening system. | AA3 | 24 months |
2.5. | First Session Court, 1st Floor | 24 months | |
2.5.1. | The door is inaccessible because it requires 10 pounds of force to open. | D2 | 24 months |
2.5.2. | The counsel tables are inaccessible because they provide 25 inches of clear knee height. | T1 | 24 months |
2.5.3. | There is no signage informing the public of the availability of an assistive listening system. | AA3 | 24 months |
2.5.4. | The route between the spectator seating and the well is inaccessible because it is only 27 inches wide. | AR3 | 24 months |
2.6. | Jury Courtroom B, 2nd Floor | ||
2.6.1. | The witness stand and jury box are inaccessible because they can be accessed only by steps. | AA8 | 24 months |
2.6.2. | The door is inaccessible because it requires more than 5 pounds of force to open. | D2 | 24 months |
2.6.3. | There is no signage informing the public of the availability of an assistive listening system. | AA3 | 24 months |
2.7. | Jury Courtroom A, 2nd Floor | ||
2.7.1. | The witness stand is inaccessible because it can be accessed only by steps. | AA8 | 24 months |
2.7.2. | The door is inaccessible because it requires more than 5 pounds of force to open. | D2 | 24 months |
2.7.3. | There is no signage informing the public of the availability of an assistive listening system. | AA3 | 24 months |
2.7.4. | The door to the jury deliberation room is inaccessible because knob hardware is used. | D1 | 24 months |
2.7.5. | The toilet rooms contain a number of inaccessible elements and are not accessible to people with disabilities. | SU13 | 24 months |
2.8. | Second Session Court, 2nd Floor | ||
2.8.1. | The witness stand is inaccessible because it can be accessed only by steps. | AA8 | 24 months |
2.8.2. | The door is inaccessible because it requires more than 5 pounds of force to open. | D2 | 24 months |
2.8.3. | There is no signage informing the public of the availability of an assistive listening system. | AA3 | 24 months |
2.9. | Third Session Court, 2nd Floor | ||
2.9.1. | The door is inaccessible because it requires more than 5 pounds of force to open. | D2 | 24 months |
2.9.2. | The route to the witness stand is inaccessible because it is only 15 inches wide due to the presence of the bench and would be 22 inches wide even if the bench were removed. | AR3 | 24 months |
2.9.3. | The counsel tables are inaccessible because they provide 25 inches of clear knee height. | T1 | 24 months |
2.9.4. | There is no signage informing the public of the availability of an assistive listening system. | AA3 | 24 months |
2.10. | Fourth Session Court, 2nd Floor | ||
2.10.1. | The door is inaccessible because it requires more than 5 pounds of force to open. | D2 | 24 months |
2.10.2. | The route to the witness stand is inaccessible because it is only 282 inches wide. | AR3 | 24 months |
2.10.3. | There is no signage informing the public of the availability of an assistive listening system. | AA3 | 24 months |
2.11. | Probation Department, 1st Floor. The counter is inaccessible because it is 422 inches above the finished floor. | C6 | 24 months |
2.12. | Clerk's Office, 1st Floor. The counter is inaccessible because it is 432 inches above the finished floor. | C6 | 24 months |
2.13. | Men's 1st Floor Toilet Room with Stalls | ||
2.13.1. | The toilet room sign is mounted above the door and has no raised or Braille characters. | TR17 | 24 months |
2.13.2. | No accessible mirror has been provided. | TR14 | 24 months |
2.13.3. | The urinal is inaccessible because the rim is more than 17 inches above the finished floor. | TR20 | 24 months |
2.13.4. | The designated accessible toilet stall is inaccessible because it is 48 inches long and 542 inches wide. | ST16 | 24 months |
2.13.5. | The designated accessible toilet is inaccessible because the top of the seat is 20 inches above the finished floor. | ST20 | 24 months |
2.13.6. | The designated accessible toilet is inaccessible because its centerline is 24 inches from the side wall. | ST17 | 24 months |
2.13.7. | The designated accessible toilet is inaccessible because the flush control is on the closed side. | ST2 | 24 months |
2.13.8. | The side grab bar at the designated accessible toilet is inaccessible because it is obstructed by the toilet paper dispenser. | ST8 | 24 months |
2.13.9. | The route to the stall is inaccessible because it is only 19 inches wide between the partitions. | AR3 | 24 months |
2.14. | Women's 1st Floor Toilet Room with Stalls | ||
2.14.1. | The toilet room sign is mounted on the door and has no raised or Braille characters. | TR17 | 24 months |
2.14.2. | The door is inaccessible because it requires more than 5 pounds of force to open. | D2 | 24 months |
2.14.3. | The pull side of the door, which is accessed through a front approach, is inaccessible because it has only 112 inches of clear space on the latch side. | D6 | 24 months |
2.14.4. | No accessible mirror has been provided. | TR14 | 24 months |
2.14.5. | The paper towel dispenser protrudes into the walkway and is not detectable to blind persons using a cane. | AR8 | 24 months |
2.14.6. | The designated accessible toilet is inaccessible because the top of the seat is 21 inches above the finished floor. | ST20 | 24 months |
2.14.7. | The designated accessible toilet is inaccessible because its centerline is 24 inches from the side wall. | ST17 | 24 months |
2.14.8. | No accessible coat hook has been provided. | TR1 | 24 months |
2.14.9. | The side grab bar at the designated accessible toilet is inaccessible because it is obstructed by the toilet paper dispenser. | ST8 | 24 months |
2.15. | 1st Floor Drinking Fountain. Although a designated accessible drinking fountain is provided, there is no drinking fountain provided for people who have difficulty bending or stooping. | DF3 | 24 months |
2.16. | Drug Court, Basement Level. The door is inaccessible because knob hardware is used. | D1 | 24 months |
2.17. | Juvenile Court, Basement Level | ||
2.17.1. | The door is inaccessible because knob hardware is used. | D1 | 24 months |
2.17.2. | The counter on the door protrudes into the walkway and is not detectable to blind persons using a cane. | AR8 | 24 months |
2.18. | Probation Cashier, Basement Level. The counter is inaccessible because it is 42 inches above the finished floor. | C6 | 24 months |
2.19. | Small Claims Department, Basement Level. The counter is inaccessible because it is 42 inches above the finished floor. | C6 | 24 months |
2.20. | Restraining Orders, Basement Level. The door is inaccessible because knob hardware is used. | D1 | 24 months |
2.21. | Basement Level Drinking Fountain | ||
2.21.1. | The drinking fountain is inaccessible because it has a spout that is 402 inches above the finished floor. | DF6 | 24 months |
2.21.2. | The drinking fountain is inaccessible because the flow of water is 2 inches high. | DF7 | 24 months |
2.21.3. | The wall-mounted drinking fountain is inaccessible because it provides only 22 inches of clear knee height. | DF5 | 24 months |
2.22. | Men's Basement Level Single User Toilet Room | 24 months | |
2.22.1. | The toilet room sign is mounted on the door and has no raised or Braille characters. | TR17 | 24 months |
2.22.2. | The door is inaccessible because it requires more than 5 pounds of force to open. | D2 | 24 months |
2.22.3. | Although an audible alarm is provided in this facility, there is no visual alarm appliance in the toilet room. | TR21 | 24 months |
2.22.4. | No accessible mirror has been provided. | TR14 | 24 months |
2.22.5. | The paper towel dispenser is inaccessible because it is mounted 59 inches above the finished floor over the counter. | TR4 | 24 months |
2.22.6. | The toilet is inaccessible because the flush control is on the closed side. | SU1 | 24 months |
2.22.7. | The side grab bar at the toilet is inaccessible because it is obstructed by the toilet paper dispenser. | SU7 | 24 months |
2.23. | Women's Basement Level Single User Toilet Room | 24 months | |
2.23.1. | The toilet room sign is mounted on the door and has no raised or Braille characters. | TR17 | 24 months |
2.23.2. | The door is inaccessible because it requires more than 5 pounds of force to open. | D2 | 24 months |
2.23.3. | Although an audible alarm is provided in this facility, there is no visual alarm appliance in the toilet room. | TR21 | 24 months |
2.23.4. | No accessible mirror has been provided. | TR14 | 24 months |
2.23.5. | The paper towel dispenser is inaccessible because it is mounted 59 inches above the finished floor over the counter. | TR4 | 24 months |
2.23.6. | The side grab bar at the toilet is inaccessible because it is obstructed by the toilet paper dispenser. | SU7 | 24 months |
2.24. | Elevator | 24 months | |
2.24.1. | The elevator is inaccessible because the hall call buttons are mounted 54 inches above the finished floor. | E3 | 24 months |
2.24.2. | The elevator is inaccessible because there are no hall lanterns provided. | E11 | 24 months |
2.24.3. | The elevator is inaccessible because there is no hoistway signage provided. | E12 | 24 months |
2.24.4. | The elevator is inaccessible because the car control buttons do not have raised and Braille characters, the car control button for the main entry floor is not designated by a raised star, and the highest button is mounted 59 inches above the finished floor. | E4 | 24 months |
2.25. | Men's 2nd Floor Toilet Room with Stalls | 24 months | |
2.25.1. | The toilet room sign is mounted above the door and has no raised or Braille characters. | TR17 | 24 months |
2.25.2. | The lavatory is inaccessible because the top of the rim is 35 inches above the finished floor. | TR11 | 24 months |
2.25.3. | The urinal is inaccessible because the rim is 182 inches above the finished floor. | TR20 | 24 months |
2.25.4. | The toilet stall is inaccessible because it is 52 inches wide. | ST16 | 24 months |
2.25.5. | The toilet is inaccessible because the top of the seat is 20 inches above the finished floor. | ST20 | 24 months |
2.25.6. | The toilet is inaccessible because its centerline is 242 inches from the side wall. | ST17 | 24 months |
2.25.7. | The toilet is inaccessible because the flush control is on the closed side. | ST2 | 24 months |
2.25.8. | The side grab bar at the toilet is inaccessible because it is obstructed by the toilet paper dispenser. | ST8 | 24 months |
2.26. | Women's 2nd Floor Toilet Room with Stalls | 24 months | |
2.26.1. | The toilet room sign is mounted on the door and has no raised or Braille characters. | TR17 | 24 months |
2.26.2. | No accessible mirror has been provided. | TR14 | 24 months |
2.26.3. | The paper towel dispenser is inaccessible because it is mounted with the controls 57 inches above the finished floor. | TR5 | 24 months |
2.26.4. | The toilet stall is inaccessible because it is 47 inches wide. | ST16 | 24 months |
2.26.5. | The toilet is inaccessible because the top of the seat is 192 inches above the finished floor. | ST20 | 24 months |
2.26.6. | The toilet is inaccessible because its centerline is 24 inches from the side wall. | ST17 | 24 months |
2.26.7. | The side grab bar at the toilet is inaccessible because it is obstructed by the toilet paper dispenser. | ST8 | 24 months |
2.27. | Conference Room behind Third Session Courtroom | ||
2.27.1. | The door is inaccessible because knob hardware is used. | D1 | 24 months |
2.27.2. | The toilet room is inaccessible and there is no signage directing people with disabilities to the accessible toilet rooms. | TR16 | 24 months |
2.28. | 2nd Floor Drinking Fountain | 24 months | |
2.28.1. | The drinking fountain is inaccessible because it has a spout that is 40 inches above the finished floor. | DF6 | 24 months |
2.28.2. | The drinking fountain is inaccessible because the controls require 10 pounds of force to operate. | DF2 | 24 months |
2.28.3. | The wall-mounted drinking fountain is inaccessible because it provides only 21 inches of clear knee height. | DF5 | 24 months |
2.29. | 2nd Floor ABar Counsel Only@ Conference Room | 24 months | |
2.29.1. | The door is inaccessible because knob hardware is used. | D1 | 24 months |
2.29.2. | The door is inaccessible because it requires more than 5 pounds of force to open. | D2 | 24 months |
2.30. | Sally Port. The route through the Sally Port is inaccessible because it contains a step. | AR2 | 24 months |
2.31. | Holding Cells. The holding cells have standard toilets and lavatories that are not accessible to persons with disabilities. | TR7 | 24 months |
3. | Presidents Golf Course | ||
3.1. | Parking. The parking lot, with a total of 90 parking spaces, is inaccessible because there are no spaces designated as accessible. This lot requires 1 van accessible space and 3 standard accessible spaces. | P3 | 24 months |
3.2. | Entrances | ||
3.2.1. | Both entrances are inaccessible because each contains at least one step. | AR1 | 24 months |
3.2.2. | The rear entrance door is inaccessible because there is a 12 inch high threshold. | D23 | 24 months |
3.3. | Men's Toilet Room with Stalls | ||
3.3.1. | The toilet room sign is mounted on the door. | TR18 | 24 months |
3.3.2. | The door is inaccessible because it requires more than 5 pounds of force to open. | D2 | 24 months |
3.3.3. | The air dryer and paper towel dispenser protrude into the walkway and are not detectable to blind persons using a cane. | AR8 | 24 months |
3.3.4. | The toilet paper dispenser in the designated accessible stall is inaccessible because it is mounted 18 inches above the finished floor and 44 inches from the rear wall. | ST19 | 24 months |
3.3.5. | The grab bars at the designated accessible toilet are inaccessible because they are mounted 302 inches above the finished floor. | ST12 | 24 months |
3.4. | Women's Toilet Room with Stalls | ||
3.4.1. | The toilet room sign is mounted on the door. | TR18 | 24 months |
3.4.2. | The door is inaccessible because it requires more than 5 pounds of force to open. | D2 | 24 months |
3.4.3. | The paper towel dispenser protrudes into the walkway and is not detectable to blind persons using a cane. | AR8 | 24 months |
3.4.4. | The toilet paper dispenser in the designated accessible stall is inaccessible because it is mounted 18 inches above the finished floor and 39 inches from the rear wall. | ST19 | 24 months |
3.4.5. | The grab bars at the designated accessible toilet are inaccessible because they are mounted 302 inches above the finished floor. | ST12 | 24 months |
3.5. | Drinking Fountain outside Pro Shop | ||
3.5.1. | The drinking fountain is inaccessible because it has a spout that is 392 inches above the finished floor. | DF6 | 24 months |
3.5.2. | The wall-mounted drinking fountain is inaccessible because it provides only 18 inches of clear knee height. | DF5 | 24 months |