ATTACHMENT K: Program Access in Existing FacilitiesPlease Note: Paragraph 48 of the Agreement requires that within three months of the effective date of this Agreement, the City will provide signage as necessary to comply with 28 C.F.R. § 35.163(b), after having surveyed all facilities that are the subject of this Agreement for the purpose of identifying those that have multiple entrances not all of which are accessible. The technical requirements and, where appropriate, the scoping requirements of the Standards are used as a guide for determining whether a program or activity held in an existing facility is "readily accessible to and usable by" persons with disabilities and for determining what changes are necessary to make this program or activity accessible if it continues to be provided in the existing facility in question. See 28 C.F.R. §§ 35.150(b)(1), 35.151. The chart below lists the facilities surveyed by the Department, the access issues identified during the survey, and the actions required to correct the access issues. Required actions are listed using an alphanumeric code. The key to the alphanumeric codes is provided in Attachment M to this Agreement. In order to ensure that the programs, services, and activities housed in the City´s facilities are accessible to persons with disabilities, when viewed in their entirety, the City will take the actions referenced by the alphanumeric code and described in detail in Attachment M to this Settlement Agreement within the time period specified below, which time period begins to run on the effective date of the Agreement. |
|||
Item # |
Access Issue
|
Required Action |
Completion Date |
---|---|---|---|
1 |
Aamodt Park, locate at Wood Street and Marquette Avenue |
||
1.1 |
The route to the picnic table is inaccessible because it is not firm, stable or slip resistant. |
AR1 |
24 months |
2 |
Beukema Park, located at 1140 Welsey Avenue |
||
2.1 |
Men´s Toilet Room with Stalls |
||
2.1.a |
The toilet room sign is mounted on the door with its centerline at 54 inches above the finish floor. |
TR18 |
6 months |
2.1.b |
The urinal is inaccessible because the rim is 22 inches high. |
TR20 |
36 months |
2.1.c |
The urinal is inaccessible because the flush control is 49 inches high. |
TR20 |
36 months |
2.1.d |
The designated accessible stall is incorrectly configured as an ambulatory stall, and there is no standard accessible stall provided. |
ST1 |
36 months |
2.2 |
Women´s Toilet Room with Stalls |
||
2.2.a |
The toilet room sign is mounted on the door with its centerline at 54 inches above the finish floor. |
TR18 |
36 months |
2.2.b |
The lavatory is inaccessible because it lacks knee and toe clearances. |
TR8 |
36 months |
2.2.c |
The designated accessible stall is incorrectly configured as an ambulatory stall, and there is no standard accessible stall provided. |
ST1 |
36 months |
2.3 |
Parking: The parking lot is inaccessible because it is gravel and unmarked, and no designated accessible spaces are provided. This lot requires 1 van accessible space and 1 standard accessible space. |
P3 |
36 months |
2.4 |
Accessible Route: There is no accessible path to the playground because it is not firm, stable, and slip-resistant. |
AR1 |
36 months |
2.4.a |
There is no accessible route to the picnic tables. |
AR1 |
36 months |
2.4.b |
There is no accessible route to the playground. |
AR1 |
36 months |
2.5 |
Drinking Fountain near toilet rooms |
||
2.5.a |
The drinking fountain is inaccessible because it has a spout that is 38 inches high. |
DF6 |
36 months |
2.5.b |
Although a designated accessible drinking fountain is provided, there is no drinking fountain provided for people who have difficulty bending or stooping. |
DF3 |
36 months |
3 |
City Hall, located at 933 Terrance Street |
||
3.1 |
Parking Lot |
||
3.1.a |
The parking lot, with a total of 25 parking spaces, is inaccessible because it only has 1 standard space designated as accessible and no van accessible space. This lot requires 1 van accessible space. |
P3 |
12 months |
3.1.b |
The parking lot is inaccessible because there are no access aisles. |
P1 |
12 months |
3.2 |
Exterior Accessible Route: The curb ramp is inaccessible because it has a slope of 9.1% and the slope of the flared side is 32.6%. |
AR5 |
36 months |
3.3 |
Interior Door: The door to room 105 is inaccessible because it requires greater than 5 pounds of force to open. |
D2 |
12 months |
3.4 |
Elevator |
||
3.4.a |
The elevator is inaccessible because the hall lanterns do not emit an audible signal indicating when a car is answering a call. |
E11 |
36 months |
3.4.b |
The elevator is inaccessible because the emergency controls require tight grasping and pinching to operate. |
E9 |
6 months |
3.5 |
Men´s and Women´s Toilet Room with Stalls near Elevators |
||
3.5.a |
There is no signage directing people with disabilities to the accessible toilet rooms. |
TR16 |
12 months |
3.6 |
Unisex Single User Toilet Room (Altered) 2nd Floor |
||
3.6.a |
The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact. |
TR12 |
6 months |
3.6.b |
The lavatory is inaccessible because it has clear floor space 12 inches wide. |
TR8 |
6 months |
3.6.c |
The toilet is inaccessible because the top of the seat is 16½ inches high. |
SU18 |
6 months |
3.7 |
Counter: The counter in room 205 is inaccessible because it is 42½ inches high. |
C6 |
36 months |
3.8 |
Commissioners Chambers |
||
3.8.a |
The door is inaccessible because it requires 8 pounds of force to open. |
D2 |
12 months |
3.8.b |
The chambers containing 60 seats is inaccessible because no wheelchair seating areas are provided. A total of 4 wheelchair seating areas is required. |
AA6 |
6 months |
3.8.c |
The chambers is inaccessible to people with hearing disabilities because there is no assistive listening system provided. This chambers requires 2 receivers. |
AA5 |
24 months |
3.9 |
Women´s Toilet Room with Stalls, 1st Floor (Altered) |
||
3.9.a |
The push side of the door, which is accessed from the latch side of the door, is inaccessible because it has inadequate clear space on the latch side. |
D11 |
6 months |
3.9.b |
No accessible mirror has been provided. |
TR14 |
12 months |
3.9.c |
The lavatory is inaccessible because a trash receptacle obstructs the clear floor space in front of the lavatory. |
TR11 |
12 months |
3.9.d |
The sanitary napkin dispenser is inaccessible because the controls require twisting of the wrist to operate. |
TR3 |
36 months |
3.9.e |
The air dryer protrudes into the walkway and is not detectable to blind persons using a cane. |
AR8 |
12 months |
3.9.f |
The toilet paper dispenser in the designated accessible stall is inaccessible because it is mounted above the side grab bar. |
ST19 |
12 months |
3.10 |
Men´s Toilet Room with Stalls, 1st Floor (Altered) |
||
3.10.a |
The push side of the door, which is accessed from the latch side of the door, is inaccessible because it has inadequate clear space on the latch side. |
D11 |
6 months |
3.10.b |
The air dryer protrudes into the walkway and is not detectable to blind persons using a cane. |
AR8 |
12 months |
3.10.c |
The toilet paper dispenser in the designated accessible stall is inaccessible because it is mounted above the side grab bar. |
ST19 |
12 months |
4 |
Muskegon Police Station, located at 980 Jefferson Street |
||
4.1 |
Visitor Parking: The parking lot, with a total of 14 parking space, is inaccessible because it has 4 spaces designated as standard accessible spaces with none as van-accessible. This lot requires 1 van accessible space. |
P3 |
12 months |
4.2 |
Ramp |
||
4.2.a |
The ramp is inaccessible because it slopes up to 9.2%. |
R3 |
36 months |
4.2.b |
The ramp is inaccessible because the handrails are 32 inches above the finished floor and the ends of the handrails lack 12 inch extensions. |
R2 |
36 months |
4.3 |
Telephone near main entrance |
||
4.3.a |
The telephone is inaccessible because it is 60 inches high to the highest operable part. |
TT1 |
36 months |
4.3.b |
The telephone protrudes into the walkway and is not detectable to blind persons using a cane. |
AR8 |
36 months |
4.3.c |
Drinking Fountain: Although a designated accessible drinking fountain is provided, there is no drinking fountain provided for people who have difficulty bending or stooping. |
DF3 |
36 months |
4.4 |
Reception Counter: The counter is inaccessible because it is 45 inches high. |
C6 |
6 months |
4.5 |
Vestibule and Doors in Series at Entrance: Because the vestibule between doors is inaccessible, the City has agreed to install an automatic door opener. |
N/A |
36 months |
5 |
Pere Marquette Park, located at 1839 Beach Street |
||
5.1 |
Parking Lot |
||
5.1.a |
The parking lot, with a total of 193 parking spaces, is inaccessible because it only has 5 spaces designated as accessible. This lot requires 1 van accessible space and 5 standard accessible spaces. |
P3 |
12 months |
5.1.b |
The parking reserved for persons with disabilities is inaccessible because the two far right designated accessible spaces in the row of four designated accessible spaces and access aisle, and the sole south designated accessible space, have slopes and cross-slopes exceeding 2%. |
P7 |
6 months |
5.1.c |
The parking lot is inaccessible because there are no access aisles serving the two leftmost designated accessible spaces in the row of four designated accessible spaces. |
P1 |
6 months |
5.2 |
Accessible Portable Toilet Room near Mac Shack Building |
||
5.2.a |
The toilet paper dispenser is inaccessible because it is mounted 55½ inches above the finished floor. |
SU17 |
6 months |
5.2.b |
The hand sanitizer dispenser is inaccessible because it is mounted with the controls 50½ inches high. |
TR5 |
6 months |
5.2.c |
The toilet is inaccessible because the top of the seat is 23 3/4 inches high. |
SU18 |
6 months |
5.2.d |
The toilet is inaccessible because the grab bars provided are incorrectly configured. |
SU10 |
6 months |
5.3 |
Parking Lot with 194 spaces (6 of which are designated as being accessible) |
||
5.3.a |
The parking lot, with a total of 194 parking spaces, is inaccessible because it does not have any van accessible spaces, there are no access aisles, and the cross-slopes for two of the spaces are greater than 2%. This lot requires 1 van accessible space and 5 standard accessible spaces. |
P3 |
6 months |
5.4 |
Parking Lot with 214 spaces (7 of which are designated as being accessible) |
||
5.4.a |
The parking reserved for persons with disabilities is inaccessible because it lacks appropriate vertical signage for van accessible spaces. |
P6 |
6 months |
5.4.b |
The parking lot is inaccessible because there are no access aisles accompanying two of the designated accessible parking spaces. |
P1 |
6 months |
5.5 |
Ramp to Captain Jacks |
||
5.5.a |
The ramp is inaccessible because it slopes up to 11.1% and there is no level or slip-resistant landing at the bottom of the ramp. |
R5 |
6 months |
5.5.b |
The ramp is inaccessible because there is no handrail on one side, the ends of the handrail are not rounded or returned, the handrail lacks extensions at the top and bottom of the ramp, the handrail surface is not smooth or free of splinters, and the handrail is more than 1½ inches in diameter. |
R4 |
6 months |
5.6 |
Captain Jacks |
||
5.6.a |
The door is inaccessible because there is a 1½ inch high threshold. |
D23 |
6 months |
5.6.b |
The counter is inaccessible because it is 46 inches high. |
C5 |
6 months |
5.6.c |
There is no access to the lower level of the facility for people with mobility impairments. |
AR9 |
6 months |
5.6.d |
Men´s Toilet Room with Stalls |
||
5.6.d(1) |
The toilet room sign is mounted on the door and is not mounted with its centerline at 60 inches above the finished floor. |
TR18 |
6 months |
5.6.d(2) |
The door is inaccessible because it requires 9 pounds of force to open. |
D2 |
6 months |
5.6.d(3) |
The air dryer protrudes into the walkway and is not detectable to blind persons using a cane. |
AR8 |
6 months |
5.6.d(4) |
The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact. |
TR12 |
6 months |
5.6.d(5) |
The lavatory is inaccessible because the controls require twisting of the wrist to operate. |
TR3 |
6 months |
5.6.d(6) |
The designated accessible toilet is inaccessible because there is insufficient clear floor space due to the stall door swing. |
ST18 |
6 months |
5.6.d(7) |
The designated accessible toilet is inaccessible because its centerline is 18½ inches from the side wall. |
ST17 |
6 months |
5.6.d(8) |
The designated accessible toilet is inaccessible because the top of the seat is 15½ inches above the finished floor. |
ST20 |
6 months |
5.6.d(9) |
The rear grab bar at the designated accessible toilet is inaccessible because it is mounted with its closer end 7 inches from the side wall. |
ST4 |
6 months |
5.6.e |
Women´s Toilet Room with Stalls |
||
5.5.e(1) |
The toilet room sign does not have raised and Braille characters. |
TR18 |
6 months |
5.5.e(2) |
The door is inaccessible because it requires 8 pounds of force to open. |
D2 |
6 months |
5.5.e(3) |
The air dryer protrudes into the walkway and is not detectable to blind persons using a cane. |
AR8 |
6 months |
5.5.e(4) |
The lavatory is inaccessible because the controls require twisting of the wrist to operate. |
TR3 |
6 months |
5.5e(5) |
The baby changing station is inaccessible because it is mounted with the controls 51 inches high. |
TR5 |
6 months |
5.6.e(1) |
The designated accessible toilet is inaccessible because there is insufficient clear floor space due to the stall door swing. |
ST18 |
6 months |
5.7 |
Snack Shop / Toilet Room Building |
||
5.7.a |
Women´s Toilet Room with Stalls |
||
5.7.a(1) |
The toilet room sign is mounted with its centerline 68 inches above the finished floor. |
TR18 |
6 months |
5.7.a(2) |
The route to the paper towel dispenser is blocked by the trash can. |
AR2 |
6 months |
5.7.a(3) |
The lavatory is inaccessible because the faucets require 12 pounds of force to operate. |
TR3 |
6 months |
5.7.a(4) |
No accessible coat hook has been provided. |
TR1 |
6 months |
5.7.a(5) |
The designated accessible stall is incorrectly configured as an ambulatory stall, and there is no standard accessible stall provided. |
ST1 |
36 months |
5.7.b |
Men´s Toilet Room with Stalls at the Snack Shop |
||
5.7.b(1) |
The toilet room sign is mounted with its centerline 68 inches above the finished floor. |
TR18 |
6 months |
5.7.b(2) |
The route to the paper towel dispenser is blocked by the trash can. |
AR2 |
6 months |
5.7.b(3) |
The lavatory is inaccessible because the faucets require 10 pounds of force to operate. |
TR3 |
6 months |
5.7.b(4) |
The urinal is inaccessible because the flush control is 48½ inches high and requires 10 pounds of force to operate. |
TR20 |
36 months |
5.7.b(5) |
The designated accessible stall is incorrectly configured as an ambulatory stall, and there is no standard accessible stall provided. |
ST1 |
36 months |
5.7.c |
Drinking Fountains near Toilet Rooms at Snack Shop |
||
5.7.c(1) |
The drinking fountain is inaccessible because it has a spout that is 39 inches high. |
DF6 |
6 months |
5.7.c(2) |
The drinking fountain is inaccessible because the flow of water is 2 inches high. |
DF7 |
6 months |
5.7.c(3) |
The drinking fountain is inaccessible because the controls require 10 pounds of force to operate. |
DF2 |
6 months |
5.7.c(4) |
Although a designated accessible drinking fountain is provided, there is no drinking fountain provided for people who have difficulty bending or stooping. |
DF3 |
6 months |
5.7.c(5) |
The drinking fountain protrudes into the walkway and is not detectable to blind persons using a cane. |
AR8 |
6 months |
5.7.d |
Counters at the Snack Shop |
||
5.7.d(1) |
The front snack counter is inaccessible because it is 42 inches high. |
C5 |
6 months |
5.7.d(2) |
The back snack counter is inaccessible because it is 42 inches high. |
C5 |
6 months |
5.7.e |
Outdoor Rinse Shower on Beach: The shower is inaccessible because it is mounted with the controls 61 inches high. |
TR5 |
24 months |
5.7.e(1) |
The shower is inaccessible because the controls require 10 pounds of force to operate. |
TR3 |
24 months |
5.8 |
Accessible Routes |
||
5.8.a |
The paved route from the shower area through the beach is inaccessible because there is a 1 inch vertical change in level at both ends of the concrete sidewalk. |
AR1 |
36 months |
5.8.b |
The route to the play area is inaccessible because it is not firm, stable, and slip-resistant. |
AR1 |
36 months |
5.8.c |
The route to the emergency phone is inaccessible because it is not firm, stable, and slip-resistant. |
AR1 |
36 months |
6 |
Muskegon Farmers Market, located at 700 Yuba Street[1] |
||
6.1 |
The parking lot, with a total of 208 parking spaces, is inaccessible because it does not have any spaces designated as van accessible. In addition, the access aisles range from 41 ½ inches to 49 inches wide. This lot requires 1 van accessible space and 6 standard accessible spaces. |
P3 |
12 months |
6.2 |
Women´s Toilet Room with Stalls |
||
6.2.a |
The toilet room contains a number of inaccessible elements and is not accessible to people with disabilities. |
ST14 |
36 months |
6.3 |
Men´s Toilet Room with Stalls |
||
6.3.a |
The toilet room contains a number of inaccessible elements and is not accessible to people with disabilities. |
ST14 |
36 months |
6.4 |
Accessible Route: The route to the produce aisles is inaccessible because the ramps serving them slope up to 10.6% and have no accessible features, and the ramps have vertical level changes in excess of ½ inch. |
AR1 |
36 months |
7 |
Fishermans´ Landing, located at 545 Ottawa Street |
||
7.1 |
Parking: The parking lot, with a total of 280 parking spaces, is inaccessible because it has no spaces designated as accessible. This lot requires 1 van accessible space and 6 standard accessible spaces. |
P3 |
12 months |
7.2 |
Public pay telephone next to toilet rooms |
||
7.2.a |
The telephone is inaccessible because it is 55 inches high to the highest operable part, and there is a picnic bench that impedes the clear floor space of the telephone. |
TT1 |
6 months |
7.2.b |
The telephone protrudes into the walkway and is not detectable to blind persons using a cane. |
AR8 |
6 months |
7.3 |
Accessible Route: The route to the boat launch is inaccessible because it is not firm, stable, and slip-resistant. |
AR1 |
12 months |
7.4 |
Women´s Toilet Room with Stalls[2] |
||
7.4.a |
The toilet room contains a number of inaccessible elements and is not accessible to people with disabilities. |
ST14 |
6 months |
7.5 |
Men´s Toilet Room with Stalls[3] |
||
7.5.a |
The toilet room contains a number of inaccessible elements and is not accessible to people with disabilities. |
ST14 |
6 months |
7.6 |
Boat Launch Ramps: The route onto the docks is inaccessible because the change in level at each dock is greater than 1/4 inch and is not beveled. |
AR1 |
12 months |
7.7 |
Picnic Pavilion |
||
7.7.a |
The route to the picnic pavilion is inaccessible because it is not firm, stable, and slip-resistant because of grass. |
AR1 |
36 months |
7.7.b |
The route to the grill is inaccessible because it is not firm, stable, and slip-resistant. |
AR1 |
36 months |
7.8 |
The route to the playground equipment is inaccessible because it is not firm, stable, and slip-resistant. |
AR1 |
36 months |
7.8.a |
The route into and out of the bathhouse and toilet rooms is inaccessible because the route is not firm, stable, and slip-resistant. |
AR1 |
36 months |
7.9 |
Bathhouse and Toilet Rooms for Campers (New Construction) |
||
7.9.a |
Unisex Shower Stall: The transfer shower is inaccessible because the transfer seat is not mounted on the wall adjacent the controls. |
B10 |
6 months |
7.9.b |
Women´s Toilet Room with Stalls |
||
7.9.b(1) |
The feminine product dispenser protrudes into the walkway and is not detectable to blind persons using a cane. |
AR8 |
6 months |
7.8.b(2) |
The air dryers protrude into the walkway and are not detectable to blind persons using a cane. |
AR8 |
6 months |
7.9.b(2) |
The designated accessible toilet is inaccessible because its centerline is 19 inches from the side wall. |
ST17 |
6 months |
7.9.c |
Men´s Toilet Room with Stalls |
||
7.9.c(1) |
The air dryers protrude into the walkway and are not detectable to blind persons using a cane. |
AR8 |
6 months |
7.9.c(2) |
The urinal is inaccessible because the flush control is 45 inches high. |
TR20 |
6 months |
7.9.c(3) |
The designated accessible toilet is inaccessible because its centerline is 19 inches from the side wall. |
ST17 |
6 months |
8 |
St. Joseph Park, located at Monroe near 5th Street |
||
8.1 |
The route to the playground equipment is inaccessible because there is a 5 inch change in level down to the equipment. |
AR1 |
6 months |
8.2 |
The picnic tables are inaccessible because none provide the required knee space. |
PD6 |
24 months |
8.3 |
Although a designated accessible drinking fountain is provided, there is no drinking fountain provided for people who have difficulty bending or stooping. |
DF3 |
36 months |
9 |
Clara Shepherd Park, located at W. Southern Avenue and Glade Street |
||
9.1 |
The parking lot, with a total of 13 parking spaces, is inaccessible because there are no spaces reserved for persons with disabilities. This lot requires 1 van accessible space. |
P3 |
12 months |
9.2 |
The drinking fountain is inaccessible because the controls require greater than 5 pounds of force to operate. |
DF2 |
6 months |
9.2.a |
Although a designated accessible drinking fountain is provided, there is no drinking fountain provided for people who have difficulty bending or stooping. |
DF3 |
36 months |
10 |
Margaret Drake Elliott Park, located at 1585 Beach Street |
||
10.1 |
Parking near Maintenance |
||
10.1.a |
The parking lot, with a total of 24 parking spaces, is inaccessible because there is no designated van accessible spaces and the two designated accessible spaces lack access aisles. This lot requires a total of 1 van accessible space. |
P3 |
12 months |
10.1.b |
The route from this parking lot to the sidewalk is inaccessible because there is no curb ramp provided. |
AR1 |
36 months |
10.2 |
Accessible Route to Play Areas: The route to the play areas is inaccessible because there is a step where the sidewalks meet the play surface, and the play surface itself is not firm, stable, and slip-resistant. |
AR1 |
36 months |
10.3 |
Women´s Toilet Room with Stalls by maintenance building |
||
10.3.a |
The toilet room sign is mounted on the door and is mounted with its centerline 69 inches above the finished floor. |
TR18 |
6 months |
10.3.b |
The door is inaccessible because there is a 1½ inch high threshold. |
D23 |
12 months |
10.3.c |
The paper towel dispenser is inaccessible because it is blocked by the trash can. |
TR2 |
6 months |
10.3.d |
The faucet is inaccessible because the controls require 7 pounds of force to operate. |
TR3 |
6 months |
10.3.e |
The designated accessible stall is incorrectly configured as an ambulatory stall, and there is no standard accessible stall provided. |
ST1 |
36 months |
10.4 |
Men´s Toilet Room with Stalls, by maintenance building |
||
10.4.a |
The toilet room sign is mounted on the door and is mounted with its centerline 69 inches above the finished floor. |
TR18 |
6 months |
10.4.b |
The door is inaccessible because there is a 1½ inch high threshold. |
D23 |
12 months |
10.4.c |
The paper towel dispenser is inaccessible because it is blocked by the trash can. |
TR2 |
6 months |
10.4.d |
The faucet is inaccessible because the controls require 7 pounds of force to operate. |
TR3 |
6 months |
10.4.e |
The designated accessible toilet is inaccessible because the flush control requires 20 pounds of force to operate. |
ST2 |
6 months |
10.4.f |
The designated accessible stall is incorrectly configured as an ambulatory stall, and there is no standard accessible stall provided. |
ST1 |
36 months |
10.5 |
Drinking Fountains near Toilet Rooms |
||
10.5.a |
The drinking fountain is inaccessible because the water flow is not within 3 inches of the front of the fountain. |
DF1 |
6 months |
10.5.b |
Although a designated accessible drinking fountain is provided, there is no drinking fountain provided for people who have difficulty bending or stooping. |
DF3 |
24 months |
10.6 |
Picnic Pavilion with accessible tables |
||
10.6.a |
The route to the grill is inaccessible because it is only 34 inches wide. |
AR3 |
36 months |
10.6.b |
The electrical outlet is inaccessible because it is 69 inches high. |
TR5 |
36 months |
10.7 |
Parking near Picnic Pavilion: The parking lot with 62 spaces, of which 6 are designated as being standard accessible spaces, is inaccessible because there are no access aisles, no space designated as van-accessible, and one of the designated accessible spaces has a cross-slope of 2.5%. This lot requires 1 van accessible space and 2 standard accessible spaces. |
P3 |
12 months |
11 |
Hartshorn Marina, located at 910 West Western Avenue |
||
11.1.a |
Parking near Marina Building: The parking lot, with a total of 189 parking spaces, is inaccessible because, although there are 8 spaces designated as being accessible, these spaces have the following violations: there are no van accessible spaces, 5 of the spaces lack access aisles, 1 space has an access aisle that measures 57 inches wide but has a curb ramp that protrudes impermissibly into the access aisle, all 8 spaces have slopes and cross-slopes exceeding 2%, and 1 space lacks appropriate vertical signage. This lot requires 1 van accessible space and 5 standard accessible spaces. |
P3 |
18 months |
11.1.b |
Accessible Route to most Accessible Pier: The ramp leading to the pier is inaccessible because it has a slope of 12.5%. |
R5 |
6 months |
11.1.c |
Picnic Tables: The picnic tables are inaccessible because none provide the required knee space. |
PD6 |
12 months |
11.2 |
Marina Office |
||
11.2.a |
The entrance door is inaccessible because there is a 4 inch high threshold. |
D23 |
24 months |
11.3 |
Women´s Toilet Room with Stalls, Marina Office |
||
11.3.a |
The toilet room sign is inaccessible. |
TR18 |
6 months |
11.3.b |
The paper towel dispenser protrudes into the walkway and is not detectable to blind persons using a cane. |
AR8 |
6 months |
11.3.c |
The designated accessible toilet is inaccessible because its centerline is 22½ inches from the side wall. |
ST17 |
24 months |
11.3.d |
The toilet paper dispenser in the designated accessible stall is inaccessible because it is mounted above the side grab bar. |
ST19 |
6 months |
11.3.e |
No accessible coat hook has been provided. |
TR1 |
6 months |
11.4 |
Men´s Toilet Room with Stalls, Marina Office |
||
11.4.a |
The toilet room sign is inaccessible. |
TR18 |
6 months |
11.4.b |
The designated accessible toilet is inaccessible because its centerline is 21½ inches from the side wall. |
ST17 |
24 months |
11.4.c |
The toilet paper dispenser in the designated accessible stall is inaccessible because it is mounted above the side grab bar. |
ST19 |
6 months |
11.4.d |
No accessible coat hook has been provided. |
TR1 |
6 months |
11.5 |
Unisex Shower Stall, Right OR Left Side |
||
11.5.a |
The entry door is inaccessible because knob hardware is used. |
D1 |
6 months |
11.5.b |
The dimensions of the shower are inaccessible, there is no clear floor space provided, and no transfer seat is provided. |
B8 |
36 months |
11.5.c |
The transfer shower is inaccessible because a grab bar is provided on one side only. |
B9 |
36 months |
11.5.d |
The shower is inaccessible because the controls are mounted 35 inches above the finished floor. |
B11 |
36 months |
12 |
Smith Ryerson Community Center/Park, located at 525 Summer Avenue (also a polling place) |
||
12.1 |
Parking: The parking lot, with a total of 73 parking spaces, is inaccessible because it only has 2 spaces reserved for persons with disabilities, there are no access aisles, and there is no van accessible space. This lot requires 1 van accessible space and 2 standard accessible spaces. |
P3 |
24 months |
12.2 |
Exterior Accessible Route to Community Center |
||
12.2.a |
The picnic tables located on the route are inaccessible because none provide the required knee space. |
PD6 |
24 months |
12.2.b |
There is no accessible route provided to the playground. |
AR1 |
24 months |
12.3 |
Community Center Exterior Entrance and Doors |
||
12.3.a |
The main exterior entrance door is inaccessible because there is a slope of 3% within the door´s required maneuvering clearance. |
D13 |
18 months |
12.3.b |
The main exterior entrance door is inaccessible because there is a 1 1/8 inch high threshold. |
D23 |
18 months |
12.4 |
Interior Accessible Route throughout Community Center |
||
12.4.a |
The fuse box near the main entrance protrudes into the walkway and is not detectable to blind persons using a cane. |
AR8 |
6 months |
12.4.b |
The route into the boxing ring is inaccessible because it has 3 steps. |
AR2 |
6 months |
12.5 |
Community Center unisex toilet room near boxing ring: There is no signage directing people with disabilities to the accessible toilet rooms. |
TR16 |
6 months |
12.6 |
Drinking Fountains in hallway at Community Center |
||
12.6.a |
The drinking fountain is inaccessible because the flow of water is not at least 4 inches high. |
DF7 |
6 months |
12.6.b |
The wall-mounted drinking fountain is inaccessible because it provides only 25½ inches of clear knee height. |
DF5 |
24 months |
12.7 |
Men´s Toilet Room with Stalls at Community Center |
||
12.7.a |
The toilet room sign is mounted with its centerline 56 inches above the finished floor. |
TR18 |
9 months |
12.7.b |
The baby changing station is inaccessible because it is mounted with the controls 57 inches high. |
TR5 |
9 months |
12.7.c |
The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact. |
TR12 |
9 months |
12.7.d |
The designated accessible toilet is inaccessible because its centerline is 19½ inches from the side wall. |
ST17 |
18 months |
12.7.e |
The designated accessible toilet is inaccessible because the flush control is on the closed side. |
ST2 |
18 months |
12.8 |
Women´s Toilet Room with Stalls at Community Center |
||
12.8.a |
The toilet room sign is mounted with its centerline 56 inches above the finished floor. |
TR18 |
9 months |
12.8.b |
The baby changing station is inaccessible because it is mounted with the controls 57 inches high and the counter is 38 inches above the finished floor. |
TR5 |
9 months |
12.8.c |
The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact. |
TR12 |
9 months |
12.8.d |
The designated accessible toilet is inaccessible because its centerline is 18½ inches from the side wall. |
ST17 |
18 months |
12.8.e |
The designated accessible toilet is inaccessible because the flush control is on the closed side. |
ST2 |
18 months |
12.8.f |
Although there are 6 toilet stalls, there is no ambulatory stall provided. |
ST1 |
18 months |
12.9 |
Exterior Drinking Fountain, near play field toilet rooms: The drinking fountain is inaccessible because the spout is higher than 36 inches, it is not on an accessible route, and there is no access for people who have trouble bending or stooping. |
DF1, AR1 |
24 months |
12.10 |
Parking near Play fields: The parking lot, with a total of 9 parking spaces, is inaccessible because there is no accessible parking provided. This lot requires 1 van accessible space. |
P3 |
24 months |
13 |
Veterans Memorial Park, located at North Causeway Street |
||
13.1 |
Parking: There are several gravel parking lots around the park. These parking lots are inaccessible because their surfaces are not firm, stable, and slip-resistant, and there are no designated accessible spaces. Each lot requires 1 van accessible space. |
P3 |
36 months |
13.2 |
Exterior Accessible Route through Park: The bridge across the pond is inaccessible because there are no compliant handrails provided. |
R4 |
36 months |
14 |
O. A. Seyferth Park, located at Lebouf Street |
||
14.1.a |
Men´s Toilet Room with Stalls near West Sherman |
||
14.1.b |
The toilet room sign is inaccessible. |
TR18 |
12 months |
14.1.c |
The air dryer protrudes into the walkway and is not detectable to blind persons using a cane. |
AR8 |
24 months |
14.1.d |
The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact. |
TR12 |
6 months |
14.1.e |
The lavatory controls are inaccessible because they require 12 pounds of force to operate. |
TR2 |
12 months |
14.1.f |
The urinal flush control is inaccessible because it requires 13 pounds of force to operate. |
TR2 |
12 months |
14.1.g |
The stall toilet flush control is inaccessible because it requires 15 pounds of force to operate. |
TR2 |
12 months |
14.2 |
Women´s Toilet Room with Stalls near West Sherman |
||
14.2.a |
The toilet room sign is inaccessible. |
TR18 |
12 months |
14.2.b |
The air dryer protrudes into the walkway and is not detectable to blind persons using a cane. |
AR8 |
24 months |
14.2.c |
The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact. |
TR12 |
6 months |
14.2.d |
The lavatory is inaccessible because it has clear floor space 29½ inches wide and 33½ inches deep. |
TR8 |
36 months |
14.2.e |
The lavatory controls are inaccessible because they require 12 pounds of force to operate. |
TR2 |
12 months |
14.2.f |
The stall toilet flush control is inaccessible because it requires 15 pounds of force to operate. |
TR2 |
12 months |
14.3 |
Drinking Fountains by Toilet Rooms near West Sherman |
||
14.3.a |
The drinking fountain is inaccessible because it has a spout that is 37 inches high. |
DF6 |
6 months |
14.3.b |
The drinking fountain is inaccessible because the flow of water is 2 inches high. |
DF7 |
6 months |
14.3.c |
The drinking fountain is inaccessible because the controls require 7 pounds of force to operate. |
DF2 |
6 months |
14.3.d |
Although a designated accessible drinking fountain is provided, there is no drinking fountain provided for people who have difficulty bending or stooping. |
DF3 |
24 months |
14.4 |
Picnic Shelter: The route to the grill is inaccessible because it is not firm, stable, and slip-resistant. |
AR1 |
36 months |
14.5 |
Picnic Tables throughout the Park: The picnic tables are inaccessible because none provide the required knee space. |
PD6 |
36 months |
14.6 |
Play Area (altered): The route to enter the play area is inaccessible because there is a step. |
AR1 |
36 months |
14.7 |
Ballfield: The route to the ballfield is inaccessible because it is not firm, stable, and slip-resistant. |
AR1 |
36 months |
14.8 |
Hockey Skating Rink (altered): The route to the hockey skating rink is inaccessible because it is not firm, stable, and slip-resistant. |
AR1 |
36 months |
14.9 |
Parking Lot #2, near Leon Street: The parking reserved for persons with disabilities is inaccessible because it lacks appropriate vertical signage indicating that the space is van accessible. |
P6 |
12 months |
15 |
Grand Truck Launch Ramp, located at McCracken Street and Lakeshore Drive |
||
15.1 |
Exterior Accessible Route: The route to the pay station is inaccessible because it is not firm, stable, and slip-resistant. |
AR1 |
36 months |
16 |
Donald J. Campbell Park, located at 1003 Young Avenue |
||
16.1 |
Parking: The parking lot, with a total of 91 parking spaces, is inaccessible because it does not have a space designated as van accessible, the leftmost designated accessible parking space´s signage is mounted too low, the two farthest right designated accessible parking spaces do not have access aisles and have inaccessible slopes due to vertical changes in level exceeding ½ inch running throughout them. This lot requires 1 van accessible space and 3 standard spaces. |
P3 |
12 months |
16.2 |
Exterior Accessible Route from Center of Parking Lot to Playing Fields |
||
16.2.a |
The route to the ballfields and bleachers is inaccessible because it is not firm, stable, and slip-resistant. |
AR1 |
36 months |
16.2.b |
The route to the basketball court is inaccessible because it is not firm, stable, and slip-resistant. |
AR1 |
36 months |
16.3 |
Men´s Toilet Room with Stalls along Center Path |
||
16.3.a |
The toilet room sign is mounted on the door with its centerline 75 inches high. |
TR18 |
12 months |
16.3.b |
The urinal is inaccessible because the rim is not elongated. |
TR20 |
36 months |
16.3.c |
No accessible coat hook has been provided. |
TR1 |
6 months |
16.3.d |
The toilet paper dispenser in the designated accessible stall is inaccessible because it is mounted above the side grab bar. |
ST19 |
6 months |
16.4 |
Women´s Toilet Room with Stalls up the Center Path |
||
16.4.a |
The toilet room sign is mounted on the door with its centerline 75 inches high. |
TR18 |
6 months |
16.4.b |
The paper towel dispenser is inaccessible because it is mounted with the controls more than 48 inches high, and a forward reach is required. |
TR5 |
12 months |
16.4.c |
No accessible coat hook has been provided. |
TR1 |
6 months |
16.5 |
Ramp alongside the Toilet Rooms toward the bleachers |
||
16.5.a |
The ramp is inaccessible because it slope up to 10.7%. |
R5 |
36 months |
16.5.b |
The ramp is inaccessible because there are only handrails on one side of the ramp, the handrail is 32 inches above the finished floor, and the handrail lacks extensions at the top and bottom of the ramp. |
R4 |
36 months |
17 |
Norman F. Kruse Park, located at 3112 Sherman Avenue |
||
17.1 |
Parking Lot near ramp to beach with multiple segments: The parking lot, with a total of 62 parking spaces, is inaccessible because it lacks "van accessible" signage. This lot requires 1 van accessible space and 2 standard accessible parking spaces. |
P3 |
12 months |
17.2 |
Ramp Leading to Beach Area Overview |
||
17.2.a |
The ramp is inaccessible because it slopes up to 9.4%. |
R3 |
36 months |
17.2.b |
The ramp is inaccessible because the handrails are not stable, they lack extensions at the top and bottom of the ramp, the ends are not rounded or returned, the diameter of the handrails exceeds 1½ inches, and the handrails are not smooth and free of splinters and sharp objects. |
R2 |
36 months |
17.3 |
Parking Lot near playground: The parking lot, with a total of 156 parking spaces, is inaccessible because it lacks access aisles, there is no van accessible space, and several spaces have slopes exceeding 2%. This lot requires 1 van accessible space and 5 standard spaces. |
P3 |
36 months |
17.4 |
Exterior Accessible Route near Play Area: The route to the play area from the parking lot is inaccessible because it has cross slopes up to 3.3%. |
AR1 |
36 months |
17.5 |
Pavilion 1: The route to the barbeque is inaccessible because it is not firm, stable, and slip-resistant. |
AR1 |
36 months |
17.6 |
Exterior Accessible Route to Play Area: The route to the play area is inaccessible because it has cross slopes of up to 4.0% and there is a 3½ to 4 inch vertical change in level where the walkway meets the play area. |
AR1 |
36 months |
17.7 |
Exterior Accessible Route to Walking Path: The route to the walking path is inaccessible because it slopes up to 10.3% with a cross slope of 3.4%. |
AR1 |
36 months |
17.8 |
Drinking Fountains near Pavilion Toilet Rooms |
||
17.8.a |
The drinking fountain is inaccessible because the flow of water is 2½ inches high. |
DF7 |
6 months |
17.8.b |
The drinking fountain is inaccessible because the water flow is 5 inches from the front of the fountain and the controls require 13 pounds of force to operate. |
DF1 |
6 months |
17.8.c |
Although a designated accessible drinking fountain is provided, there is no drinking fountain provided for people who have difficulty bending or stooping. |
DF3 |
24 months |
17.9 |
Men´s Toilet Room with Stalls near Pavilion |
||
17.9.a |
The toilet room sign is mounted on the door with its centerline 67½ inches above the finished floor. |
TR18 |
12 months |
17.9.b |
The door is inaccessible because there is a ½ inch high unbeveled threshold. |
D23 |
12 months |
17.9.c |
The lavatory is inaccessible because the rim or counter is 36 inches high to the top. |
TR11 |
36 months |
17.9.d |
The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact. |
TR12 |
6 months |
17.9.e |
The soap dispenser is inaccessible because it is mounted 45½ inches high behind the lavatory. |
TR4 |
12 months |
17.9.f |
The lavatory controls are inaccessible because they require 18 pounds of force to operate. |
TR2 |
12 months |
17.9.g |
The urinal flush control is inaccessible because it requires 15 pounds of force to operate. |
TR2 |
12 months |
17.9.h |
The urinal is inaccessible because the clear floor space centered on the urinal is less than 30 inches wide. |
TR20 |
12 months |
17.9.i |
The flush control in the designated accessible stall is inaccessible because it requires 18 pounds of force to operate. |
TR2 |
12 months |
17.9.j |
The toilet paper dispenser in the designated accessible stall is inaccessible because it is mounted 45½ inches from the rear wall. |
ST19 |
12 months |
17.9.k |
The side grab bar at the designated accessible toilet is inaccessible because it is mounted 13 inches from the rear wall. |
ST7 |
12 months |
17.9.l |
The rear grab bar at the designated accessible toilet are inaccessible because it is mounted 32½ inches high. |
ST12 |
12 months |
17.10 |
Women´s Toilet Room with Stalls near Pavilion |
||
17.10.a |
The toilet room sign is mounted on the door with its centerline 67½ inches above the finished floor. |
TR18 |
12 months |
17.10.b |
The door is inaccessible because there is a 3/4 inch high unbeveled threshold. |
D23 |
12 months |
17.10.c |
The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact. |
TR12 |
12 months |
17.10.d |
The lavatory controls are inaccessible because they require 11 pounds of force to operate. |
TR2 |
12 months |
17.10.e |
The soap dispenser is inaccessible because it is mounted 45½ inches high behind the lavatory. |
TR4 |
12 months |
17.10.f |
The flush control in the designated accessible stall is inaccessible because it requires 17 pounds of force to operate. |
TR2 |
12 months |
17.10.g |
The toilet paper dispenser in the designated accessible stall is inaccessible because it is mounted 47½ inches from the rear wall. |
ST19 |
12 months |
17.10.h |
The side grab bar at the designated accessible toilet is inaccessible because it is mounted 13 inches from the rear wall. |
ST7 |
12 months |
18 |
Reese Park, located at 1299 East Forrest Street |
||
18.1 |
Parking lot near playground: The parking lot, with a total of less than 50 parking spaces, is inaccessible because it has no spaces designated as accessible. This lot requires 1 van accessible space and 1 standard accessible space. |
P3 |
36 months |
18.2 |
Exterior Picnic Tables: The picnic tables are inaccessible because none provide the required knee space. |
PD6 |
36 months |
18.3 |
Exterior Accessible Route from Parking to Sidewalk and Playground: The route from the parking lot to the sidewalk is inaccessible because there is a 2 inch vertical change in level where the parking lot meets the sidewalk. |
AR1 |
36 months |
18.4 |
Men´s Toilet Room with Stalls |
||
18.4.a |
The toilet room sign is inaccessible. |
TR18 |
12 months |
18.4.b |
The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact. |
TR12 |
6 months |
18.4.c |
The rear grab bar at the designated accessible toilet is inaccessible because it is split by the toilet water pipe. |
ST4 |
36 months |
18.5 |
Drinking Fountains near Toilet Rooms: Although a designated accessible drinking fountain is provided, there is no drinking fountain provided for people who have difficulty bending or stooping. |
DF3 |
24 months |
18.6 |
Women´s Toilet Room with Stalls |
||
18.6.a |
The toilet room sign is mounted on the door and has no raised and Braille characters. |
TR18 |
12 months |
18.6.b |
The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact. |
TR12 |
6 months |
18.6.c |
The rear grab bar at the designated accessible toilet is inaccessible because it is split by the toilet water pipe. |
ST4 |
36 months |
18.7 |
Exterior Accessible Route to Softball Field 1 |
||
18.7.a |
One of the electrical boxes protrudes into the walkway and is not detectable to blind persons using a cane. |
AR8 |
36 months |
18.7.b |
The route to the dugout is inaccessible because there are two steps. |
AR1 |
36 months |
18.8 |
Parking Lot near fields |
||
18.8.a |
The parking lot, with a total of 37 parking spaces, is inaccessible because no spaces are reserved for persons with disabilities. This lot requires 1 van accessible space and 1 standard accessible space. |
P3 |
36 months |
18.8.b |
There is no accessible route to any of the park amenities from this parking lot. |
AR1 |
36 months |
19 |
Sheldon Park Shelter, located at 1162 Madison Avenue |
||
19.1 |
Parking lot: The parking lot, with a total of less than 50 parking spaces, is inaccessible because it has no spaces designated as accessible. This lot requires 1 van accessible space and 1 standard accessible space. |
P3 |
36 months |
19.2 |
Exterior Accessible Routes |
||
19.2.a |
The route from the gravel parking lot to the sidewalk is inaccessible because a curb cut is not provided. |
AR1 |
36 months |
19.2.b |
The routes to the playground, swings, basketball court, softball field and bleachers are inaccessible because they are not firm, stable, and slip-resistant. |
AR1 |
36 months |
19.3 |
Toilet Rooms: The toilet rooms were not surveyed because they were locked. |
ST14 |
36 months |
20 |
McGraft Park and Community Center, located at 1600 Glen Avenue (also a polling place) |
||
20.1 |
Parking: The parking lot, with a total of 64 parking spaces, is inaccessible because there are no van accessible spaces, all of the access aisles are less than 60 inches wide, there is no vertical signage, the pavement markings are not clear, the access aisle for the rightmost parking space near the tennis courts has a slope of 2.3%. This lot requires one van accessible space and two standard spaces. |
P3 |
36 months |
20.2 |
Accessible Route from Parking to Community Center: The route to the community center is inaccessible because the curb cut has no detectable warnings and the flared sides slope up to 51.9% |
AR1 |
36 months |
20.3 |
Exterior Entrance: The exterior entry door is inaccessible because the vestibule is not sufficiently deep. |
D3 |
36 months |
20.4 |
Men´s Toilet Room with Stalls |
||
20.4.a |
The toilet room sign is inaccessible. |
TR17 |
36 months |
20.4.b |
The door is inaccessible because it is only 31 inches wide and requires more than 5 pounds of force to open. |
D1, D2 |
36 months |
20.4.c |
The door is inaccessible because the pull side of the door, which is accessed through a front approach, is inaccessible because it has only 8 3/4 inches of clear space on the latch side. |
D7 |
36 months |
20.4.d |
The toilet room door swings into the required clear floor space at the lavatory. |
TR6 |
36 months |
20.4.e |
No accessible mirror has been provided. |
TR14 |
36 months |
20.4.f |
The toilet room is inaccessible because there is insufficient turning space provided within the room. |
TR19 |
36 months |
20.4.g |
The paper towel dispenser is inaccessible because it is mounted with the controls 54 inches high and a forward reach is required. |
TR5 |
36 months |
20.4.h |
The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact. |
TR12 |
36 months |
20.4.i |
The designated accessible stall is incorrectly configured as an ambulatory stall, and there is no standard accessible stall provided. |
ST15 |
36 months |
20.5 |
Women´s Toilet Room with Stalls |
||
20.5.a |
The toilet room sign is inaccessible. |
TR17 |
36 months |
20.5.b |
The door is inaccessible because it is only 31 inches wide and requires more than 5 pounds of force to open. |
D1, D2 |
36 months |
20.5.c |
The door is inaccessible because the pull side of the door, which is accessed through a front approach, is inaccessible because it has only 12½ inches of clear space on the latch side. |
D7 |
36 months |
20.5.d |
The toilet room door swings into the required clear floor space at the lavatory. |
TR6 |
36 months |
20.5.e |
No accessible mirror has been provided. |
TR14 |
36 months |
20.5.f |
The toilet room is inaccessible because there is insufficient turning space provided within the room. |
TR19 |
36 months |
20.5.g |
The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact. |
TR12 |
36 months |
20.5.h |
The designated accessible stall is incorrectly configured as an ambulatory stall, and there is no standard accessible stall provided. |
ST15 |
36 months |
20.6 |
Drinking Fountain |
||
20.6.a |
The wall mounted drinking fountain is inaccessible because it provides only 25 inches of clear knee height. |
DF5 |
24 months |
20.6.b |
Although a designated accessible drinking fountain is provided, there is no drinking fountain provided for people who have difficulty bending or stooping. |
DF3 |
24 months |
20.7 |
Interior Route |
||
20.7.a |
The route to the kitchen is inaccessible because the door is only 29 inches wide, and there are only 21 inches between counters |
AR2 |
36 months |
20.7.b |
The route to the stage is inaccessible because there are two steps. |
AR2 |
36 months |
20.8 |
Men´s and Women´s Exterior Toilet Rooms Outside Community Center: The men´s and women´s toilet rooms contain a number of inaccessible elements and are not accessible to people with disabilities. |
TR22 |
36 months |
20.9 |
Exterior Drinking Fountain Near Community Center Entrance |
||
20.9.a |
The drinking fountain is inaccessible because it has a spout that is 38 inches high, the flow of water is less than 4 inches high, the water flow is not within 3 inches of the front of the fountain, the controls require more than 5 pounds of force to operate, and there is no drinking fountain provided for people who have difficulty bending or stooping. |
DF1 |
36 months |
20.9.b |
The drinking fountain protrudes into the walkway and is not detectable to blind persons using a cane. |
AR8 |
36 months |
20.10 |
Exterior Accessible Route |
||
20.10.a |
There is no accessible route to the music shell, ballfield, picnic tables, or playgrounds from the community center, parking lots, or street because of steps or the lack of a firm, stable, and slip-resistant surface. |
AR1 |
36 months |
20.11 |
Assembly Area - Music Shell |
||
20.11.a |
There is no accessible route to the stage because there are steps leading to it. |
AA1 |
36 months |
20.11.b |
The music shell is inaccessible to people with hearing disabilities because there is no assistive listening system provided. |
AA4 |
36 months |
20.12 |
Men´s and Women´s Toilet Stalls inside Music Shell |
||
20.12.a |
The men´s and women´s toilet rooms contain a number of inaccessible elements and are not accessible to people with disabilities. |
TR22 |
36 months |
21 |
Public Service Building, located at 1350 E. Keating Avenue |
||
21.1 |
Parking: The parking lot, with a total of 95 parking spaces of which 4 are designated as being accessible, is inaccessible because there are no van accessible spaces, all of the access aisles are 56 inches wide, and the signage is mounted too low. This lot requires one van accessible space and three standard spaces. |
P3 |
12 months |
22 |
CW Marsh Field, located at E. Holbrook Avenue |
||
22.1 |
Parking: The parking lot, with a total of 141 parking spaces, is inaccessible because there are no van accessible spaces, and there is an inadequate access aisle for the rightmost designated accessible spaces. This lot requires 1 van accessible space and 4 standard spaces. |
P3 |
12 months |
22.2 |
Drinking Fountain: The drinking fountain is inaccessible because it has a spout that is 41 inches high, there are only 11½ inches of knee space depth, and there is no drinking fountain provided for people who have difficulty bending or stooping. |
DF1 |
36 months |
22.3 |
Ramp to Stadium Seating: The ramp to stadium seating is inaccessible because the lower leg has a cross slope of 2.1%, the second leg has a running slope of 9.8%, handrails are provided on one side only, the handrails are 41 inches high, the inside handrails are not continuous, and the extensions at the top and bottom are not parallel with the ground surface. |
R3 |
36 months |
22.4 |
Exterior Accessible Routes |
||
22.4.a |
The routes to the press box, dugout, and bleacher area are inaccessible because the areas are only accessible by steps. |
AR1 |
36 months |
22.4.b |
The routes to the play area and picnic tables are inaccessible because they are not firm, stable, and slip-resistant. |
AR1 |
36 months |
22.5 |
Men´s Toilet Room with Stalls behind stadium seating |
||
22.5.a |
The toilet room sign is inaccessible. |
TR17 |
12 months |
22.5.b |
The door to the toilet room is inaccessible because there is a 3/4 inch high unbeveled threshold. |
D22 |
12 months |
22.5.c |
The lavatory is inaccessible because the rim or counter is 38½ inches high to the top, the bottom edge of the apron is 28 inches above the finished floor, and the controls require 15 pounds of force to operate. |
TR9 |
36 months |
22.5.d |
The urinal is inaccessible because the rim is 18 inches high and the flush control requires 17 pounds of force to operate. |
TR9, TR20 |
36 months |
22.5.e |
The designated accessible stall is incorrectly configured as an ambulatory stall, and there is no standard accessible stall provided. |
ST15 |
36 months |
22.6 |
Women´s Toilet Room with Stalls behind stadium seating |
||
22.6.a |
The toilet room sign is inaccessible. |
TR17 |
12 months |
22.6.b |
The door to the toilet room is inaccessible because there is a 3/4 inch high unbeveled threshold. |
D22 |
12 months |
22.6.c |
No accessible mirror has been provided. |
TR14 |
12 months |
22.6.d |
The lavatory is inaccessible because the rim or counter is 38 inches high to the top, the bottom edge of the apron is 28 inches above the finished floor, and the controls require 15 pounds of force to operate. |
TR9 |
36 months |
22.6.e |
The designated accessible stall is incorrectly configured as an ambulatory stall, and there is no standard accessible stall provided. |
ST15 |
36 months |
23 |
Evergreen Cemetery/Mausoleum, located at Irwin and Pine Streets[4] |
||
23.1 |
The route to the cemetery/mausoleum is inaccessible because it is not firm, stable, and slip-resistant. |
AR1 |
36 months |
24 |
McCrea Playfield, located at Kenneth at Catawba behind Restlawn |
||
24.1 |
Parking Lot near playground: The parking lot, with a total of 8 parking spaces of which one is designated as being accessible, is inaccessible because there are no van accessible spaces, and the pavement markings are unclear. This lot requires one van accessible space. |
P3 |
12 months |
24.2 |
Exterior Accessible Routes: The routes to the basketball court, drinking fountain, picnic tables, toilets rooms, and play area are inaccessible because they are not firm, stable, and slip-resistant. |
AR1 |
36 months |
24.3 |
Men´s and Women´s Toilet Rooms with Stalls: The men´s and women´s toilet rooms contain a number of inaccessible elements and are not accessible to people with disabilities. |
TR22 |
36 months |
24.4 |
Drinking fountain near playground |
||
24.4.a |
The drinking fountain is inaccessible because the controls require 10 pounds of force to operate. |
DF2 |
6 months |
24.4.b |
Although a designated accessible drinking fountain is provided, there is no drinking fountain provided for people who have difficulty bending or stooping. |
DF3 |
24 months |
24.5 |
Parking Lot near playfield: The parking lot next to the playfield, with a total of 35 spaces, is inaccessible because there is no van accessible space. This lot requires 1 van accessible space and 1 standard space. |
P3 |
12 months |
24.6 |
Exterior Accessible Routes |
||
24.6.a |
The routes to the concession counter, viewing bleachers, playing field and dugouts are inaccessible because they are not firm, stable, and slip-resistant. |
AR1 |
6 months |
[1]With the exception of the parking issues, the City will develop a plan for compliance within 18 months, and will complete modifications to achieve compliance with the Standards within 36 months.
[2]Compliance with this Agreement may be met through the use of adequate signage directing individuals to the accessible toilet rooms.
[3]Compliance with this Agreement may be met through the use of adequate signage directing individuals to the accessible toilet rooms.
[4]Compliance with title II for purposes of the Mausoleum program may be met through the program access option.