ATTACHMENT L: Programs Housed in Others' Facilities

Please Note: Paragraph 65 of the Agreement requires that within twelve months of the effective date of this Agreement, the County will provide signage as necessary to comply with 28 C.F.R. § 35.163(b), after having surveyed all facilities that are the subject of this Agreement for the purpose of identifying those that have multiple entrances not all of which are accessible.

The chart below lists the facilities surveyed by the Department, the access issues identified during the survey, and the actions required to correct the access issues. Required actions are listed using an alphanumeric code. The key to the alphanumeric codes is provided in Attachment M to this Agreement.

In order to ensure that the County's programs, services, and activities that are operated at facilities owned or controlled by other entities as listed below are, when viewed in their entirety, readily accessible to and usable by persons with mobility impairments, the County will ensure that the actions listed below have been accomplished within the time period specified below, which time period begins to run on the effective date of the Agreement. Alternatively, within 90 days of the effective date of this Agreement, the County will submit for review by the Department a plan for providing access for persons with disabilities to the programs, services, and activities housed in the facility.

Item # Access Issue Required Action Completion Date
1. Montrose Liquor - Montrose Crossing, Rockville, Maryland 20853
1.1. Parking. The parking lot, with a total of 14 parking spaces, is inaccessible because the 2 spaces designated as accessible are only 80 and 88 inches wide, the shared access aisle is less than 36 inches wide, and there is no van accessible signage. This lot requires 1 van accessible space. P3 36 Months
2. Juvenile Assessment Center, 7300 Calhoun Drive, Rockville, Maryland 20855
2.1. Entrance - near Room 738, HHS
2.1.a. The pull side of this entrance door, which is accessed through a front approach, is inaccessible because it has no maneuvering clearance on the latch side. D6 36 Months
2.1.b. The door is inaccessible because it has a ¾ inch threshold. D22 36 Months
2.2. Drinking Fountain. The higher drinking fountain protrudes into the walkway and is not detectable to blind persons using a cane. AR8 36 Months
2.3. Women's Toilet Room (stalls) - 700 Suite
2.3.a. The toilet room sign is mounted with its centerline 62 inches above the finished floor and is not on the latch side of the door. TR18 36 Months
2.3.b. The door is inaccessible because there is a ¾ inch threshold. D22 36 Months
2.3.c. The lavatory is inaccessible because the bottom edge of the lavatory apron is only 28 inches above the finished floor. TR11 36 Months
2.3.d. The toilet paper dispenser is inaccessible because it is mounted 45 inches from the rear wall. ST19 36 Months
2.3.e. The side grab bar at the toilet is inaccessible because its farther end is mounted 48 inches from the rear wall. ST7 36 Months
2.4. Men's Toilet Room (stalls) - 700 Suite
2.4.a. The toilet room sign is mounted with its centerline 62 inches above the finished floor and is not on the latch side of the door. TR18 36 Months
2.4.b. The door is inaccessible because there is a ¾ inch threshold. D22 36 Months
2.4.c. The baby changing area protrudes 19 inches into the walkway at a height of 34 inches above the finished floor and is not detectable to blind persons using a cane. AR8 36 Months
2.4.d. The lavatory is inaccessible because the bottom edge of the lavatory apron is only 28 inches above the finished floor. TR11 36 Months
2.4.e. The lavatory is inaccessible because the toe clearances are obstructed by a panel. TR11 36 Months
2.4.f. The urinal is inaccessible because the rim is 17 ½ inches above the finished floor, and the clear floor space provided is less than 36 inches for a depth of 35 inches. TR20 36 Months
2.4.g. The toilet paper dispenser is inaccessible because it is mounted 46 inches from the rear wall. ST19 36 Months
2.4.h. The side grab bar at the toilet is inaccessible because its farther end is mounted 48 inches from the rear wall. ST7 36 Months
2.5. Women's Toilet Room (stalls) - 600 Suite
2.5.a. The toilet room sign is mounted with its centerline 62 inches above the finished floor and is not on the latch side of the door. TR18 36 Months
2.5.b. The door is inaccessible because it has a ¾ inch threshold. D22 36 Months
2.5.c. The shelf protrudes 6 ½ inches into the walkway at a height of 67 inches above the finished floor and is not detectable to blind persons using a cane. AR8 36 Months
2.5.d. The lavatory is inaccessible because the bottom edge of the lavatory apron is only 28 inches above the finished floor. TR11 36 Months
2.5.e. The toilet paper dispenser is inaccessible because it is mounted 46 ½ inches from the rear wall. ST19 36 Months
2.5.f. The side grab bar at the toilet is inaccessible because its farther end is mounted 48 inches from the rear wall. ST7 36 Months
2.6. Men's Toilet Room (stalls) - 600 Suite
2.6.a. The toilet room sign is mounted with its centerline 62 inches above the finished floor and is not on the latch side of the door. TR18 36 Months
2.6.b. The door is inaccessible because it has a ¾ inch threshold. D22 36 Months
2.6.c. The lavatory is inaccessible because the bottom edge of the lavatory apron is only 28 inches above the finished floor. TR11 36 Months
2.6.d. The urinal is inaccessible because the clear floor space provided is less than 36 inches for a depth of 35 inches. TR20 36 Months
2.6.e. The toilet paper dispenser is inaccessible because it is mounted 46 inches from the rear wall. ST19 36 Months
2.6.f. The side grab bar at the toilet is inaccessible because its farther end is mounted 48 inches from the rear wall. ST7 36 Months
2.7. Accessible Exterior Route from Parking to the Entrance to Suite 400. The route from the accessible parking to the entrance to Suite 400 is inaccessible because a detectable warning is not provided on the curb ramp. AR5 36 Months
2.8. Accessible Exterior Route from Parking to Suites 500, 600, and 700
2.8.a. The route from accessible parking to the entrance to suites 500, 600, and 700 is inaccessible because it has a slope of up to 7.3% and a cross slope of 2.4%, it narrows to less than 36" due to cars parked along the route, suite 700 is not on the shortest accessible route from the accessible parking, and the route to the sidewalk has a slope of up to 17.5%. AR1 36 Months
2.8.b. The route from accessible parking to the entrance to suites 500, 600, and 700 is inaccessible because the curb ramp has detectable warnings and the flared side of the curb ramp has a slope of 17.5%. AR5 36 Months
2.9. Accessible Route from Accessible Parking to the Rear Entrance to Suite 700
2.9.a. The route from the accessible parking to the rear door to Suite 700 is inaccessible because it has a slope of up to 11.5% with a cross slope of up to 5.3%. AR1 36 Months
2.9.b. The route from the accessible parking to the rear entrance to Suite 700 is inaccessible because there is no detectable warning on the curb ramp and the cross slope of the curb ramp is 6.5%. AR5 36 Months
2.10. Parking at Front, Side, and Rear of the Entrance. The parking lot, with a total of 183 parking spaces, is inaccessible because there are only 2 standard accessible spaces and one van accessible space provided, one space is only 95 inches wide, and the parking spaces are not dispersed or on the shortest accessible route to the accessible entrances. This lot requires 1 van accessible space and 5 standard accessible spaces. P3 36 Months
2.11. Men's Toilet Room (stalls) - Suite 400
2.11.a. The toilet room sign is mounted with its centerline 62 inches above the finished floor and is not on the latch side of the door. TR18 36 Months
2.11.b. The lavatory is inaccessible because the bottom edge of the lavatory apron is only 28 inches above the finished floor. TR11 36 Months
2.11.c. The toilet paper dispenser is inaccessible because it is mounted 48 inches from the rear wall. ST19 36 Months
2.11.d. The side grab bar at the toilet is inaccessible because its farther end is mounted 42 inches from the rear wall. ST7 36 Months
2.12. Office - Room 700
2.12.a. The door is inaccessible because it requires 6 pounds of force to open. D2 36 Months
2.12.b. The pull side of the door, which is accessed through a front approach, is inaccessible because it has only 5 inches of clearance on the pull side due to the location of a chair. D6 36 Months
2.13. Drinking Fountain - Suite 400
2.13.a. The drinking fountain protrudes into the walkway and is not detectable to blind persons using a cane. AR8 36 Months
2.14. Women's Toilet Room (stalls) - Suite 400
2.14.a. The toilet room sign is mounted with its centerline 62 inches above the finished floor and is not on the latch side of the door. TR18 36 Months
2.14.b. The lavatory is inaccessible because the bottom edge of the lavatory apron is only 28 inches above the finished floor. TR11 36 Months
2.14.c. The toilet paper dispenser is inaccessible because it is mounted 40 inches from the rear wall. ST19 36 Months
2.14.d. The side grab bar at the toilet is inaccessible because its farther end is mounted 40 inches from the rear wall. ST7 36 Months
2.15. Drinking Fountains - Suite 400 Rear. The drinking fountain protrudes into the walkway and is not detectable to blind persons using a cane. AR8 36 Months
2.16. Women's Toilet Room (stalls) - Suite 400 Rear Entrance
2.16.a. The toilet room sign is mounted with its centerline 62 inches above the finished floor and is not on the latch side of the door. TR18 36 Months
2.16.b. The lavatory is inaccessible because the bottom edge of the lavatory apron is only 28 inches above the finished floor. TR11 36 Months
2.16.c. The toilet paper dispenser is inaccessible because it is mounted 39 inches from the rear wall. ST19 36 Months
2.16.d. The side grab bar at the toilet is inaccessible because its farther end is mounted 40 inches from the rear wall. ST7 36 Months
2.17. Men's Toilet Room (stalls) - Suite 400 Rear Entrance
2.17.a. The toilet room sign is mounted with its centerline 62 inches above the finished floor and is not on the latch side of the door. TR18 36 Months
2.17.b. The lavatory is inaccessible because the bottom edge of the lavatory apron is only 28 inches above the finished floor, and the knee and toe clearances are obstructed by a panel. TR11 36 Months
2.17.c. The toilet paper dispenser is inaccessible because it is mounted 40 inches from the rear wall. ST19 36 Months
2.17.d. The side grab bar at the toilet is inaccessible because its farther end is not mounted far enough from the rear wall. ST7 36 Months
2.18. Gallery - Room 720. The sink is inaccessible because the controls are mounted beyond the reach of people who use wheelchairs. TR4 36 Months
2.19. Conference Room
2.19.a. The pull side of the first door to the conference room, which is accessed through a front approach, is inaccessible because it has only 4 ½ inches of clear floor space width and 41 inches of clear floor space depth on the latch side. D6 36 Months
2.19.b. The second door to the conference room is inaccessible because it requires 10 pounds of force to open. D2 36 Months
2.19.c. The pull side of the second door to the conference room, which is accessed through a front approach, is inaccessible because it has only 55 inches of clear floor space depth on the latch side. D6 36 Months
2.20. Lobby (600)
2.20.a. The main counter is inaccessible because it is 42 inches above the finished floor. C6 36 Months
2.20.b. The counter ledge protrudes 6 ½ inches into the walkway at a height of 40 ½ inches above the finished floor and is not detectable to blind persons using a cane. AR8 36 Months
2.21. Front Door, Corridor (600). The door is inaccessible because it requires 10 pounds of force to open. D2 36 Months
2.22. Back Door (600). The back door is not on an accessible route because it requires the use of stairs, and directional signage is not provided. D16 36 Months
2.23. Door from 400 to 500. The door is inaccessible because it requires 13 pounds of force to open. D2 36 Months
2.24. Conference Rooms (413 and 4A). The doors to these rooms are inaccessible because they require 15 pounds of force to open. D2 36 Months
3. Jefferson Plaza, 600 East Jefferson Street - 3rd Floor, Office of Community Use of Public Facilities, Rockville, MD 20850
3.1. Men's Toilet Room - 3rd Floor in Hallway
3.1.a. Although an audible alarm is provided in this facility, there is no visual alarm appliance in the toilet room. Provide a visual alarm appliance in this room. TR21 36 Months
3.1.b. The seat cover dispenser is inaccessible because the seat covers are 56 inches above the finished floor. TR4 36 Months
3.1.c. There is no accessible stall provided. ST15 36 Months
3.2. Women's Toilet Room - 3rd Floor in Hallway
3.2.a. Although an audible alarm is provided in this facility, there is no visual alarm appliance in the toilet room. TR21 36 Months
3.2.b. The seat cover dispenser is inaccessible because the seat covers are 58 inches above the finished floor. TR4 36 Months
3.2.c. There is no accessible stall provided. ST15 36 Months
3.3. Parking at Mezzanine Level. Although the parking lot has a total of 360 parking spaces, none are designated as van accessible. P3 36 Months
3.4. Ramps to Elevator Lobby at P1, P2 and P3
3.4.a. The built-up curb ramps impermissibly extend into the access aisles. AR4 36 Months
3.4.b. The ramps are inaccessible because no edge protection is provided. R1 36 Months
4. 6th District Police Station, 18749F N. Frederick Road, Gaithersburg, Maryland 20879
4.1. Parking. Although the parking lot has a total of 85 parking spaces, only 3 spaces are designated for persons with disabilities, there is no van accessible space or access aisle, and 2 out of the 3 existing spaces designated for use by people with disabilities have a slope of 6.8%. P3 36 Months
4.2. Route from Parking area. The route from the parking to the entrance is inaccessible because there is no detectable warning at the three curb ramps. AR5 36 Months
4.3. Lobby Counter. The counter protrudes into the walkway and would not be detectable to a blind person using a cane. AR8 36 Months
4.4. Lobby Unisex Single-User Toilet Room
4.4.a. The toilet room sign is mounted on the door and its centerline is mounted 51 inches above the finished floor. TR17 36 Months
4.4.b. The force required to open the door is 11 pounds. D2 36 Months
4.4.c. No accessible mirror has been provided. TR14 36 Months
4.4.d. The designated accessible toilet is inaccessible because its centerline is 17 inches from the side wall. SU15 36 Months
4.4.e. The designated accessible toilet is inaccessible because the flush control is on the closed side. ST2 36 Months
4.5. Staff Men's Locker Room
4.5.a. The toilet room sign is mounted on the door. TR17 36 Months
4.5.b. The force required to open the door is 13 pounds. D2 36 Months
4.5.c. The door has a inch threshold. D22 36 Months
4.5.d. The seat cover dispensers are mounted 56 inches above the finished floor. TR5 36 Months
4.5.e. The urinal flush control is 46 inches above the finished floor. TR20 36 Months
4.5.f. The toilet centerline is 19½ inches from the side wall. ST17 36 Months
4.5.g. The designated accessible toilet stall is inaccessible because an office chair obstructs the clear floor space. ST18 36 Months
4.5.h. The toilet paper dispenser is mounted on the front wall. ST19 36 Months
4.5.i. The clear floor space for the transfer shower is obstructed by a mini-wall and has a curb greater than ½ inch. B7, B8 36 Months
4.5.j. The bench is inaccessible because it is 9½ inches deep and is not attached to the wall. LR1 36 Months
4.6. Staff Women's Locker Room
4.6.a. The toilet room sign is mounted on the door with its centerline 51 inches above the finished floor. TR17 36 Months
4.6.b. The force required to open the door is 13 pounds. D2 36 Months
4.6.c. The door is inaccessible because it has a threshold that is more than 3/4 inch above the finished floor. D22 36 Months
4.6.d. The seat cover dispensers are mounted 56 inches above the finished floor. TR5 36 Months
4.6.e. The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact. TR12 36 Months
4.6.f. The toilet centerline is 19½ inches from the side wall. ST17 36 Months
4.6.g. The toilet paper dispenser is mounted on the front wall. ST19 36 Months
4.6.h. The designated accessible toilet stall is inaccessible because a trash can obstructs the clear floor space. ST18 36 Months
4.6.i. The clear floor space for the transfer shower is obstructed by a mini-wall and has a curb greater than ½ inch. B7, B8 36 Months
4.6.j. Provide one full-length mirror, measuring at least 18 inches wide by 54 inches high, mounted in a position affording a view to a person on the bench as well as to a person in a standing position. LR2 36 Months
4.6.k. The bench is inaccessible because it is 9½ inches deep and is not attached to the wall. LR1 36 Months
4.7. Lounge. Although the kitchenette sink provides adequate space for a parallel approach and lowered counter, this design was intended for a forward approach; consequently, the drain and water pipes must be covered to protect from injury. TR12 36 Months
4.8. Booking Area. The gun locker protrudes into the circulation path and would not be detectable to a blind person using a cane. AR8 36 Months
4.9. Holding / Booking Unisex Single-User Toilet Room
4.9.a. The toilet room sign is mounted on the door with its centerline 51 inches above the finished floor. TR17 36 Months
4.9.b. The designated accessible toilet is inaccessible because its centerline is 19 ½ inches from the side wall. SU15 36 Months
4.9.c. The designated accessible toilet is inaccessible because the flush control is on the closed side. SU1 36 Months
4.10. Toilet Room
4.10.a. The toilet room sign is inaccessible. TR17 36 Months
4.10.b. The force required to open the door is 11 pounds. D2 36 Months
4.10.c. No accessible mirror has been provided. TR14 36 Months
4.10.d. The seat cover dispensers are mounted 57 inches above the finished floor. TR5 36 Months
4.10.e. The top of the toilet seat is 15½ inches above the finished floor. SU18 36 Months
4.10.f. The toilet paper dispenser is mounted 47 inches from the rear wall. SU17 36 Months
4.10.g. The lavatory and entrance door are inaccessible because a trash can interferes with the clear floor space. TR6 36 Months
4.10.h. The side grab bar at the toilet is mounted with the far end 47 inches from the rear wall. ST7 36 Months
4.10.i. The rear grab bar at the toilet is 24 inches long. ST4 36 Months
4.11. Women's Single-User Toilet Room near Back Entrance
4.11.a. The toilet room sign is inaccessible. TR17 36 Months
4.11.b. The force required to open the door is 9 pounds. D2 36 Months
4.11.c. There is insufficient turning space within the toilet room because of a trash can. TR19 36 Months
4.11.d. No accessible coat hook has been provided. TR1 36 Months
4.11.e. No accessible mirror has been provided. TR14 36 Months
4.11.f. The seat cover dispensers are mounted 56½ inches above the finished floor. TR5 36 Months
4.11.g. The bottom of the lavatory apron is 28 inches above the finished floor. TR11 36 Months
4.11.h. The designated accessible toilet is inaccessible because its centerline is 17 inches from the side wall. SU15 36 Months
4.11.i. There are no grab bars at the toilet. SU10 36 Months
4.11.j. The white cabinet above the toilet paper rolls protrudes and would not be detectable to a person who is blind or has low vision. AR8 36 Months
4.12. Rear Entrance Door
4.12.a. The door, which is accessed through a front approach and which has both a closer and a latch, has no maneuvering clearance width on the push side, latch side. D7 36 Months
4.12.b. The door has knob hardware. D1 36 Months
5. Montgomery Works, 11002 Viers Mill Road - Suite 100, Wheaton, MD 20902
5.1. Parking
5.1.a. The parking reserved for persons with disabilities is inaccessible because 5 of the access aisles provided are too narrow. P8 36 Months
5.1.b. The parking reserved for persons with disabilities is inaccessible because the cross slope of some of the accessible spaces measures 2.8%. P7 36 Months
5.2. Accessible Route from Van Accessible parking spaces to sidewalk near entrance. The route from van accessible spaces to sidewalk is inaccessible because the slope of the curb ramp measures 9.8% and the slope of the left flared side measures 10.1%. AR1 36 Months
5.3. Accessible Route from Standard Accessible parking spaces to sidewalk near entrance
5.3.a. The route from the parking lot to the sidewalk is inaccessible because the slope on the crosswalk measures up to 5.5%. AR1 36 Months
5.3.b. The route from the standard accessible parking spaces to the sidewalk is inaccessible because the slope of the curb ramp measures 9.4%, the slope of the left flare measures 17.2% and the slope of the right flare measures 11.6%. AR5 36 Months
5.4. Entrance Door
5.4.a. The push button on the exterior door is inaccessible because it requires 10 pounds of force to operate. D2 36 Months
5.4.b. The push button on the interior door is inaccessible because it requires 6 ponds of force to operate. TR2 36 Months
5.5. Telephones in One-Stop Career Center. The telephone is inaccessible because the coin return is mounted 56 inches above the finished floor, and the signage lacks a pictogram. TT1 36 Months
5.6. Drinking Fountains - First level by men's toilet room
5.6.a. The drinking fountain near the men's room is inaccessible because the knee space measures 26 inches. DF5 36 Months
5.6.b. Although an accessible drinking fountain is provided, there is no drinking fountain provided for people who have difficulty bending or stooping. DF3 36 Months
5.7. Designated Accessible Single-User Toilet Room
5.7.a. The toilet room sign is inaccessible. TR17 36 Months
5.7.b. The door is inaccessible because the pressure required to open the door is 24 pounds. D2 36 Months
5.7.c. No accessible mirror has been provided. TR14 36 Months
5.7.d. The lavatory is inaccessible because the bottom edge of the apron measures 27 inches above the finished floor. TR11 36 Months
5.7.e. The toilet is inaccessible because the flush control is on the closed side. SU1 36 Months
5.7.f. The side grab bar at the toilet is inaccessible because its far end measures 45 inches to the rear wall. SU6 36 Months
5.8. Elevator
5.8.a. The elevator is inaccessible because the hoistway signage is mounted 61 inches above the finished floor. E12 36 Months
5.8.b. The clearance between the car platform sill and the edge of the hoistway landing is 1 ½ inches. E10 36 Months
6. Depart of Correction & Rehabilitation, 11th Floor Corrections, Central Administration, 51 Monroe Street, Rockville, MD 20850
6.1. Elevator
6.1.a. The elevator is inaccessible because the doors start to close 4 seconds after notification. E6 36 Months
6.1.b. The elevator car controls are inaccessible because the highest operating button is 64 inches above the finished floor and the emergency controls have their centerline 21 inches above the finished floor. E7 36 Months
6.1.c. The elevator is inaccessible because, although emergency communications are provided, there is no raised lettering or symbols. E4 36 Months
6.2. Inspector General's Office - The door to the waiting room is inaccessible because the pressure required to open the door is 10 pounds. D2 36 Months
6.3. Inspector General's Office - Conference Room
6.3.a. The door is inaccessible because it has an opening width of only 29 inches. D25, AR9 36 Months
6.3.b. The door is inaccessible because knob hardware is used. D1 36 Months
6.3.c. The conference room is inaccessible to people with hearing impairments because there is no assistive listening system. AA5 36 Months
6.4. Entrance Near Parking Garage
6.4.a. The route from the parking garage to the entrance is inaccessible because the curb ramp has a slope of 14.8% and there is no obstruction and no flared side on the ramp toward the walk area. AR5 36 Months
6.5. Fountains - Inspector General - 8th Floor - Hall
6.5.a. The drinking fountain has a spout that is 42 inches above the finished floor. DF6, DF3 36 Months
6.5.b. The drinking fountain is inaccessible because the knee space allows only 23 inches height, 23 inches width and 10 inches depth. DF6 36 Months
6.5.c. Although a lower drinking fountain is provided, there is no drinking fountain provided for people who have difficulty bending or stooping. DF3 36 Months
7. TESS Community Center, 8513 Piney Branch Road, Silver Spring, Maryland 20906
7.1. Parking Lot
7.1.a. The parking lot, with a total of approximately 45 parking spaces, is inaccessible because only one space is designated as accessible, there is no designated van-accessible space, there are no access aisles, and the space designated for accessible parking is not level or on the shortest accessible route to the entrance. P3 36 Months
7.1.b. The route from the parking area to the sidewalk is inaccessible because there is no curb ramp near the accessible parking space. AR1, AR5 36 Months
7.1.c. The curb cut at the street is inaccessible because it has a running slope of 9.4% and a cross slope of 5.5%. AR5 36 Months
7.2. Front Office. The door is inaccessible because knob hardware is used. D1 36 Months
7.3. Single-User Unisex Toilet Room
7.3.a. The route to the toilet room is inaccessible because the hallway is 32 inches wide. AR3 36 Months
7.3.b. The toilet room sign is inaccessible because it is mounted on the door and has no raised characters or braille. TR17 36 Months
7.3.c. The door is inaccessible because it has an opening width of only 25 inches. D25 36 Months
7.3.d. The pressure required to open the doors is greater than 5 pounds. D2 36 Months
7.3.e. The door is inaccessible because knob hardware is used. D1 36 Months
7.3.f. The push side of the door, which is accessed from the hinge side of the door, is inaccessible because it has inadequate maneuvering clearance on the pull side. D6 36 Months
7.3.g. The toilet room door swings into the required clear floor space at the lavatory. TR8 36 Months
7.3.h. No accessible coat hook has been provided. TR1 36 Months
7.3.i. No accessible mirror has been provided. TR14 36 Months
7.3.j. There is insufficient turning space within the toilet room. TR19 36 Months
7.3.k. The seat cover dispenser is inaccessible because the seat covers are 56 inches above the finished floor. TR4 36 Months
7.3.l. The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact. TR12 36 Months
7.3.m. The faucet is inaccessible because the hardware requires twisting of the wrist to operate. TR10 36 Months
7.3.n. The toilet is inaccessible because the top of the seat is 15 ½ inches above the finished floor. SU18 36 Months
7.3.o. The toilet is inaccessible because its centerline measures 15 inches from the side wall. SU15 36 Months
7.3.p. The toilet is inaccessible because the flush control is on the closed side. SU1 36 Months
7.3.q. There are no grab bars provided. SU10 36 Months
8. Bethesda House, 4848 Cordell Avenue, Bethesda, Maryland 20814
8.1. Entrance. The route to the entrance door has an 8 inch step. AR1, D13 36 Months
8.2. Unisex Toilet Room with Stalls
8.2.a. The door is inaccessible because it has an opening width of only 22 ½ inches. D25 36 Months
8.2.b. The door is inaccessible because knob hardware is used. D1 36 Months
8.2.c. No accessible mirror has been provided. TR14 36 Months
8.2.d. The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact. TR12 36 Months
8.2.e. There is no standard accessible stall provided. ST15 36 Months
8.3. Shower Room
8.3.a. The shower is inaccessible because it has inadequate clear floor space at the opening, there is no shower seat or grab bars, the shower head is fixed 44 inches above the shower floor, and there is a 7 inch curb. B8 36 Months
8.3.b. The faucet is inaccessible because the hardware requires twisting of the wrist to operate. TR10 36 Months
8.3.c. The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact. TR12 36 Months
9. Developmental Disabilities Services, 11 N. Washington Street, Rockville, Maryland 20850
9.1. Parking
9.1.a. The parking lot is inaccessible because none of the designated accessible parking spaces are van accessible and one of the designated accessible spaces has a slope of 4.6% and the access aisle serving that space has a slope of 4.1%. This lot requires 1 van accessible space and 1 standard accessible space. P3 36 Months
9.1.b. One of the designated accessible spaces has a slope of 4.6% and the access aisle serving that space has a slope of 4.1%. P7 36 Months
9.2. Suite 450 – Large Conference Room
9.2.a. The pressure required to open the conference room entrance door is 11 pounds. D2 36 Months
9.2.b. The large courtroom is inaccessible to people with hearing impairments because there is no assistive listening system. AA5 36 Months
9.3. Small Conference Room - The small conference room is inaccessible to people with hearing impairments because there is no assistive listening system. AA5 36 Months
9.4. Lobby Elevator - The elevator is inaccessible because, although emergency communications are provided, they are not identified by raised symbols or Braille. E4 36 Months
9.5. Entrance - The pressure required to open the interior entrance door is 12 pounds. D2 36 Months
10. Piccard Drive Health Center, 1335 Piccard Drive, Rockville, Maryland
10.1. Parking
10.1.a. The parking lot, with a total of approximately 94 parking spaces, is inaccessible because there are only 3 accessible spaces. This lot requires 1 van accessible space and 3 standard accessible spaces. P3 36 Months
10.1.b. The curb ramp / route at the van accessible space is inaccessible because it has a 4% cross slope. P7 36 Months
10.2. Main Entrance - The building is inaccessible because there is no signage at the main entrance directing people to the accessible lower level entrance. D16 36 Months
10.3. Route from Parking to Lower Level Accessible Entrance - The route from the parking area to the lower level accessible entrance is inaccessible because it is not level and has a 4.5% cross slope. AR1 36 Months
10.4. Lower Level Entrance Door - The door is inaccessible because there is a cross slope of 4% within the door's required maneuvering clearance. Provide a door so that the floor or ground area within the required clearances is level and clear. Standards § 4.13.6, Fig. 25. D13 36 Months
10.5. Dental Office - The lobby counter is inaccessible because it is 24 inches wide. C6 36 Months
10.6. Hearing Clinic and Cancer Crusade counter - The office counter is inaccessible because it is only 24 inches wide. C6 36 Months
10.7. Men's Lower Level Toilet Room - Stalls
10.7.a. The toilet room sign is mounted on the door. TR17 36 Months
10.7.b. Although an audible alarm is provided in this facility, there is no visual alarm appliance in the toilet room. TR21 36 Months
10.7.c. The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact. TR12 36 Months
10.7.d. The seat cover dispenser is inaccessible because the seat covers are 60 inches above the finished floor. TR4 36 Months
10.7.e. No accessible coat hook has been provided. TR1 36 Months
10.7.f. The side grab bar at the toilet is inaccessible because its closer end is 13 inches from the rear wall. ST7 36 Months
10.7.g. The rear grab bar at the toilet is inaccessible because its closer end is 7 inches from the side wall. ST5 36 Months
10.8. Women's Lower Level Toilet Room - Stalls
10.8.a. The toilet room sign is inaccessible. TR17 36 Months
10.8.b. Although an audible alarm is provided in this facility, there is no visual alarm appliance in the toilet room. TR21 36 Months
10.8.c. The seat cover dispenser is inaccessible because the seat covers are 61 inches above the finished floor. TR4 36 Months
10.8.d. No accessible coat hook has been provided. TR1 36 Months
10.8.e. The side grab bar at the toilet is inaccessible because its closer end is 13 inches from the rear wall. ST7 36 Months
10.8.f. The rear grab bar at the toilet is inaccessible because its closer end is 7 inches from the side wall. ST4 36 Months
10.9. Toilet Room at Shady Grove Maternity Center - Single User
10.9.a. The toilet room signage is inaccessible. TR17 36 Months
10.9.b. The seat cover dispenser is inaccessible because the seat covers are 60 inches above the finished floor. TR4 36 Months
10.9.c. The lavatory is inaccessible because it requires the use of twist type hardware. TR10 36 Months
10.9.d. The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact. TR12 36 Months
10.9.e. The lavatory is inaccessible because the clear floor space is obstructed by the trash can. TR8 36 Months
10.9.f. The toilet is inaccessible because the top of the seat is 15 inches above the finished floor. SU18 36 Months
10.9.g. The toilet is inaccessible because its centerline measures 18 ¾ inches from the side wall. SU15 36 Months
10.9.h. The side grab bar at the toilet is inaccessible because its closer end is 13 inches from the rear wall. SU6 36 Months
10.9.i. The rear grab bar at the toilet is inaccessible because its closer end is 6 ½ inches from the side wall. SU3 36 Months
10.10. Men's Toilet Room on Upper Level - Stalls
10.10.a. The toilet room signage is inaccessible. TR17 36 Months
10.10.b. There is a 1 inch change in level at the threshold to the door. D23 36 Months
10.10.c. Although an audible alarm is provided in this facility, there is no visual alarm appliance in the toilet room. TR21 36 Months
10.10.d. The seat cover dispenser is inaccessible because the seat covers are 60 inches above the finished floor. TR4 36 Months
10.10.e. The coat hook is mounted 62 inches above the finished floor. TR1 36 Months
10.10.f. The side grab bar at the toilet is inaccessible because its closer end is 13 inches from the rear wall. ST7 36 Months
10.10.g. The rear grab bar at the toilet is inaccessible because its closer end is 7 inches from the side wall. ST4 36 Months
10.11. Women's Toilet Room on Upper Level - Stalls
10.11.a. The signage is inaccessible. TR17 36 Months
10.11.b. There is a 1 inch change in level at the threshold to the door. D23 36 Months
10.11.c. Although an audible alarm is provided in this facility, there is no visual alarm appliance in the toilet room. TR21 36 Months
10.11.d. The seat cover dispenser is inaccessible because the seat covers are 61 inches above the finished floor. TR4 36 Months
10.11.e. The coat hook is mounted 60 inches above the finished floor. TR1 36 Months
10.11.f. The side grab bar at the toilet is inaccessible because its closer end is 13 inches from the rear wall. ST7 36 Months
10.11.g. The rear grab bar at the toilet is inaccessible because its closer end is 7 inches from the side wall. ST4 36 Months
11. Community Based Shelter, 12250 Wilkens Avenue, Rockville, MD 20850
11.1. Accessible Route
11.1.a. The shelter door is inaccessible because the pressure required to open the door is 9 pounds. D2 36 Months
11.2. Alarms
11.2.a. Although the facility contains an emergency alarm system, the alarm system is inaccessible because it lacks visual alarms. TR21 36 Months
11.3. Women's Locker room
11.3.a. The signage provided is inaccessible because it is not mounted on the latch side of the door. D26 36 Months
11.3.b. The door is inaccessible because the pressure required to open the door is 9 pounds. D2 36 Months
11.3.c. The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact. TR12 36 Months
11.3.d. The toilet is inaccessible because its centerline measures 17 inches from the side wall. ST17 36 Months
11.3.e. The toilet is inaccessible because the flush control is on the closed side. ST2 36 Months
11.3.f. The toilet paper dispenser is inaccessible because it is mounted 40 inches from the rear wall. ST19 36 Months
11.3.g. The rear grab bar at the toilet is inaccessible because it measures 24 inches in length. ST4 36 Months
11.4. Shower
11.4.a. The shower in the women's Locker Room is inaccessible because it measures 39 inches long and 38 inches deep, the shower head is mounted 68 inches above the finished floor, and there is no seat. B8 36 Months

 