ATTACHMENT G: Program Access Modifications at Emergency Shelters
| |||
item # | Access Issue | Required Action | Completion Date |
---|---|---|---|
1 | Springbrook High School, 201 Valley Brook Drive, Silver Spring, Maryland 20904 | ||
1.1 | Entrance | ||
1.1.a | The entrance is inaccessible because it lacks a level approach within the door's required maneuvering clearance. | D13 | 14 months |
1.2 | Interior Route from main entrance to gym | ||
1.2.a | The drinking fountain protrudes into the walkway and would not be detectable to a blind person using a cane. | AR8 | 14 months |
1.3 | Boys Toilet Room E-101 with Stalls | ||
1.3.a | The entrance is inaccessible because it has a 7/8 inch high threshold. | D23 | 14 months |
1.3.b | The air dryer protrudes into the walkway and would not be detectable to a blind person using a cane. | AR8 | 14 months |
1.3.c | The air dryer controls are mounted 59 inches above the finished floor. | TR5 | 14 months |
1.3.d | The bottom of the lavatory apron is 28 inches above the finished floor. | TR5 | 14 months |
1.3.e | The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact. | TR12 | 14 months |
1.3.f | The accessible urinal was not working at the time of our inspection. | TR20 | 14 months |
1.3.g | The toilet in the designated accessible stall has a centerline that is 17 inches from the side wall. | ST17 | 14 months |
1.3.h | The toilet flush control is on the closed side. | ST2 | 14 months |
1.3.i | No accessible coat hook has been provided. | TR1 | 14 months |
1.3.j | The rear grab bar at the toilet is inaccessible because it is obstructed by the water pipe. | ST5 | 14 months |
1.4 | Girls Toilet Room with Stalls | ||
1.4.a | The entrance is inaccessible because it has a 7/8 inch high threshold. | D23 | 14 months |
1.4.b | The air dryer protrudes into the walkway and would not be detectable to a blind person using a cane. | AR8 | 14 months |
1.4.c | The air dryer controls are mounted 59 inches above the finished floor. | TR5 | 14 months |
1.4.d | The bottom of the lavatory apron is 27½ inches above the finished floor. | TR11 | 14 months |
1.4.e | Although there are 6 stalls, there is no ambulatory stall provided. | ST1 | 14 months |
1.4.f | The designated accessible toilet stall is 58 inches deep with a floor-mounted toilet. | ST16 | 14 months |
1.4.g | No accessible coat hook has been provided. | TR1 | 14 months |
1.4.h | The rear grab bar at the toilet is inaccessible because it is obstructed by the water pipe. | ST5 | 14 months |
2 | John F. Kennedy High School, 1901 Randolph Road, Silver Spring, Maryland 20902 | ||
2.1 | Front Parking Lot | ||
2.1.a | Some of the parking spaces reserved for persons with disabilities lack appropriate signage. | P6 | 14 months |
2.1.b | The parking spaces and access aisles reserved for persons with disabilities are inaccessible because they have slopes that exceed 2% and range up to 6%. | P7 | 14 months |
2.2 | Front Entrance Ramp | ||
2.2.a | The middle landing of the ramp has a slope of 3.2% and is 46 inches long. | R3 | 14 months |
2.3 | Rear Parking Lot | ||
2.3.a | The van accessible parking spaces reserved for persons with disabilities lack appropriate signage. | P6 | 14 months |
2.3.b | The parking spaces and access aisles reserved for persons with disabilities have slopes ranging from 2.2% to 3.6%, with cross slopes ranging from 2.4% to 3.6%. | P7 | 14 months |
2.4 | Rear Entrance Ramp | ||
2.4.a | The lower middle landing of the ramp is 60 inches by 57 inches, the inside handrail is not continuous, there are no handrail extensions at the bottom, and the middle leg of the ramp has a slope of 12.8%. | R2, R3 | 14 months |
2.5 | Women's Toilet Room with Stalls by Cafeteria | ||
2.5.a | The toilet room sign is mounted 36 inches above the finished floor. | TR17 | 14 months |
2.5.b | The air dryer protrudes into the walkway and would not be detectable to a blind person using a cane. | AR8 | 14 months |
2.5.c | No accessible coat hook has been provided. | TR1 | 14 months |
2.5.d | The toilet paper dispenser is mounted on the wrong wall. | ST19 | 14 months |
2.6 | Men's Toilet Room with Stalls by Cafeteria | ||
2.6.a | The toilet room sign is mounted 36 inches above the finished floor. | TR17 | 14 months |
2.6.b | The top of the toilet seat is 16 inches above the finished floor. | ST20 | 14 months |
2.6.c | No accessible coat hook has been provided. | TR1 | 14 months |
2.6.d | The toilet paper dispenser is mounted on the wrong wall. | ST19 | 14 months |
3 | Sherwood High School, 1401 Olney-Sandy Spring Road, Sandy Spring, Maryland 20860 | ||
3.1 | Parking | ||
3.1.a | Although the parking lot has a total of approximately 400 parking spaces, there are only 4 designated accessible spaces, there are no van accessible spaces, 3 of the designated accessible spaces are 93 or 94 inches wide, and the spaces and access aisles are not level. This lot requires 2 van accessible spaces and at least 7 standard accessible spaces. | P3, P8, P7 | 14 months |
3.2 | Route from parking lot to entrance | ||
3.2.a | The route from the parking lot, across the bus lane and the sidewalk to the entrance, is inaccessible because it has a slope that ranges up to 10.9%. | P7 | 14 months |
3.3 | Cafeteria Entrance | ||
3.3.a | The interior door to the cafeteria is inaccessible because it requires 15 pounds of force to open. | D2 | 14 months |
3.4 | Women's Toilet Room with Stalls by Cafeteria | ||
3.4.a | The door is inaccessible because it requires 14 pounds of force to open. | D2 | 14 months |
3.4.b | The soap dispenser is mounted over a 27 inch deep obstruction. | TR3 | 14 months |
3.4.c | The paper towel dispenser protrudes into the walkway and would not be detectable to a blind person using a cane. | AR8 | 14 months |
3.4.d | The bottom edge of the lavatory apron is 27 inches high. | TR11 | 14 months |
3.4.e | The lavatory's hot water pipes are not insulated or otherwise configured to protect against contact. | TR12 | 14 months |
3.4.f | Although there are 7 stalls, there is no ambulatory stall provided. | ST1 | 14 months |
3.4.g | No accessible coat hook has been provided. | TR1 | 14 months |
3.4.h | The toilet paper dispenser is mounted above the side grab bar, obstructing its use. | ST9 | 14 months |
3.5 | Men's Toilet Room with Stalls by Cafeteria | ||
3.5.a | The force required to open the door is inaccessible because it is 7 pounds. | D2 | 14 months |
3.5.b | No accessible mirror has been provided. | TR14 | 14 months |
3.5.c | The soap dispenser is mounted over a 27 inch deep obstruction. | TR4 | 14 months |
3.5.d | The paper towel dispenser protrudes into the walkway and would not be detectable to a blind person using a cane. | AR8 | 14 months |
3.5.e | The lavatory's hot water pipes are not insulated or otherwise configured to protect against contact. | TR12 | 14 months |
3.5.f | The toilet centerline is 19 inches from the side wall. | ST15 | 14 months |
3.5.g | The toilet flush control is on the closed side. | ST2 | 14 months |
3.5.h | No accessible coat hook has been provided. | TR1 | 14 months |
3.5.i | The toilet paper dispenser is mounted above the side grab bar, obstructing its use. | ST9 | 14 months |
3.6 | Women's Downstairs Locker Room | ||
3.6.a | The locker room sign is not mounted on the latch side of the door and does not have raised characters or Braille. | D26 | 14 months |
3.6.b | No accessible mirror has been provided. | TR14 | 14 months |
3.6.c | The paper towel dispenser is mounted with the controls 61 inches above the finished floor. | TR5 | 14 months |
3.6.d | The bottom edge of the lavatory apron is 27 inches above the finished floor. | TR11 | 14 months |
3.6.e | The hot water pipes at the lavatory are not insulated or otherwise configured to protect against contact. | TR12 | 14 months |
3.6.f | No accessible shower is provided. | B8 | 14 months |
3.6.g | The benches are less than 24 inches wide and are not attached at the wall. | LR1 | 14 months |
3.6.h | The drinking fountain is inaccessible because it has a spout that is 39 inches high. | DF6 | 14 months |
3.7 | Men's Downstairs Locker Room | ||
3.7.a | The locker room sign is not mounted on the latch side of the door and does not have raised characters or Braille. | D26 | 14 months |
3.7.b | No accessible mirror has been provided. | TR14 | 14 months |
3.7.c | The bottom edge of the lavatory apron is 28 inches above the finished floor. | TR11 | 14 months |
3.7.d | The hot water pipes at the lavatory are not insulated or otherwise configured to protect against contact. | TR12 | 14 months |
3.7.e | The designated accessible transfer shower is inaccessible because it is 31¼ inches by 32 inches, it does not have sufficient clear floor space outside the shower to facilitate a transfer, the grab bars do not comply with Figure 37(a), the shower unit is not mounted on a vertical bar, and the curb is 3½ inches high. | B8 | 14 months |
4 | Watkins Mill High School, 10301 Ridge Road, Montgomery Village, Maryland 20886 | ||
4.1 | Parking | ||
4.1.a | There is no van accessible parking space, all of the access aisles are less than 60 inches wide, and each designated accessible space and access aisle has a slope exceeding 2%, with some ranging up to 4.9%. | P3, P8, P7 | 14 months |
4.2 | Accessible Route | ||
4.2.a | The route from the parking lot to the gym entrance is inaccessible because it has a 1 inch change in level where the sidewalk meets the driveway, and the sidewalk has settled by one of the designated accessible parking spaces, creating a slope of 7% and a cross slope of 2.9%. | AR1 | 14 months |
4.2.b | The route from the parking lot to the theater entrance is inaccessible because it has a 1 inch change in level between the sidewalk panels, and the concrete wheel stop above one of the designated accessible parking spaces reduces the width of the route to 28 inches. | AR1, AR3 | 14 months |
4.3 | Gym Entrance | ||
4.3.a | The exterior entrance door is inaccessible because it has a 1 inch high threshold. | D23 | 14 months |
4.3.b | The interior gym door is inaccessible because it requires 10 pounds of force to open. | D2 | 14 months |
4.4 | Drinking Fountain by Gym | ||
4.4.a | The drinking fountain control requires 6 pounds of force to operate. | DF2 | 14 months |
4.5 | Women's Toilet Room with Stalls by Gym | ||
4.5.a | The toilet room sign is not mounted on the latch side of the door and does not have raised characters or Braille. | D26 | 14 months |
4.5.b | The door is inaccessible because it requires 7 pounds of force to open. | D2 | 14 months |
4.5.c | No accessible mirror has been provided. | TR14 | 14 months |
4.5.d | The paper towel dispenser is inaccessible because it is mounted with the controls 55 inches above the finished floor. | TR5 | 14 months |
4.5.e | The top of the lavatory rim is 36 inches above the finished floor. | TR11 | 14 months |
4.5.f | The hot water pipes at the lavatory are not insulated or otherwise configured to protect against contact. | TR12 | 14 months |
4.5.g | The rear grab bar at the toilet is inaccessible because it is obstructed by the flush valve. | ST5 | 14 months |
4.6 | Men's Toilet Room with Stalls by Gym | ||
4.6.a | There is no toilet room sign mounted on the latch side of the door and the sign does not have raised characters or Braille. | TR17 | 14 months |
4.6.b | The door is inaccessible because it requires 9 pounds of force to open. | D2 | 14 months |
4.6.c | No accessible mirror has been provided. | TR14 | 14 months |
4.6.d | The paper towel dispenser is mounted with the controls 55½ inches above the finished floor. | TR5 | 14 months |
4.6.e | The hot water pipes at the lavatory are not insulated or otherwise configured to protect against contact. | TR12 | 14 months |
4.6.f | The urinal is inaccessible because it has a 27 inch wide clear floor space, the flush is 45 inches above the finished floor, and the drain creates a cross slope exceeding 2% in the required clear floor space. | TR20 | 14 months |
4.6.g | The designated accessible toilet stall is 48 inches wide. | ST16 | 14 months |
4.6.h | The toilet flush control is on the closed side. | ST2 | 14 months |
4.6.i | The toilet paper dispenser is mounted 38½ inches from the rear wall. | ST19 | 14 months |
4.6.j | The rear grab bar at the toilet is inaccessible because it is obstructed by the flush valve. | ST5 | 14 months |
4.7 | Elevator | ||
4.7.a | The elevator lacks hoistway signage. | E12 | 14 months |
4.8 | Women's Locker Room | ||
4.8.a | The locker room sign is mounted more than 60 inches above the finished floor and does not have raised characters or Braille. | D26 | 14 months |
4.8.b | The door is inaccessible because it requires 7 pounds of force to open. | D2 | 14 months |
4.8.c | No accessible mirror has been provided. | TR14 | 14 months |
4.8.d | The paper towel dispenser is inaccessible because it is mounted with the controls 55½ inches above the finished floor. | TR5 | 14 months |
4.8.e | The hot water pipes at the lavatory are not insulated or otherwise configured to protect against contact. | TR12 | 14 months |
4.8.f | The wall-mounted shelves outside the showers protrude into the walkway and would not be detectable to a blind person using a cane. | AR8 | 14 months |
4.8.g | No accessible shower is provided. | B8 | 14 months |
4.8.h | The benches are inaccessible because they are 9½ inches wide and are not attached to the wall. | LR1 | 14 months |
4.9 | Men's Locker Room | ||
4.9.a | The locker room sign is mounted more than 60 inches above the finished floor and does not have raised or Braille characters. | D26 | 14 months |
4.9.b | The door is inaccessible because it requires 7 pounds of force to open. | D2 | 14 months |
4.9.c | No accessible mirror has been provided. | TR14 | 14 months |
4.9.d | The paper towel dispenser is inaccessible because it is mounted with the controls 68 inches above the finished floor. | TR5 | 14 months |
4.9.e | The hot water pipes at the lavatory are not insulated or otherwise configured to protect against contact. | TR12 | 14 months |
4.9.f | The wall-mounted shelves outside the showers protrude into the walkway and would not be detectable to a blind person using a cane. | AR8 | 14 months |
4.9.g | No accessible shower is provided. | B8 | 14 months |
4.1 | Cafeteria | ||
4.10.a | There is no accessible room signage. | D26 | 14 months |
4.10.b | The deli food service line is inaccessible because it is 24 inches wide. | AR3 | 14 months |
4.11 | Ramp in Cafeteria | ||
4.11.a | The ramp connecting the upper and lower levels of the cafeteria is inaccessible because it has a slope of 9.2% near the bottom, it is 32 inches wide around the post, and it does not have handrail extensions at the top and bottom. | R4, R5 | 14 months |
5 | Walt Whitman High School, 7100 Whittier Boulevard, Bethesda, Maryland 20817 | ||
5.1 | Front Parking Lot. Although the parking lot has a total of 457 parking spaces, it is inaccessible because there are only 8 spaces designated as accessible, there is no van accessible space, the access aisles are between 43 and 45 inches wide, and there are no vertical signs designating each space. This lot requires at least 2 van accessible spaces. | P3, P8, P6 | 14 months |
5.2 | Entrance. The interior vestibule door at the entrance to the gymnasium is inaccessible because it requires 10 pounds of force to open. | D2 | 14 months |
5.3 | Girls Toilet Room with Stalls across from Gymnasium | ||
5.3.a | The toilet room sign is not mounted in an accessible location and has no raised or Braille characters. | TR17 | 14 months |
5.3.b | The interior side of the doorway is inaccessible because it has an unbeveled threshold that is more than ¼ inch high. | D23 | 14 months |
5.3.c | No accessible mirror has been provided. | TR14 | 14 months |
5.3.d | The soap dispensers are inaccessible because they are mounted with the controls 50 inches above the finished floor behind the lavatory, and a front reach is required. | TR4 | 14 months |
5.3.e | Although there are 7 stalls, there is no ambulatory stall provided. | ST1 | 14 months |
5.3.f | The designated accessible toilet stall is inaccessible because it is 49½ inches wide, and the toilet centerline is 16½ inches from the side wall. | ST16, ST17 | 14 months |
5.3.g | The seat toilet height is 19 ½ above the finished floor. | ST20 | 14 months |
5.3.h | No accessible coat hook has been provided. | TR1 | 14 months |
5.3.i | The toilet paper dispenser is mounted 38½ inches from the rear wall. | ST19 | 14 months |
5.4 | Boys Toilet Room with Stalls across from Gymnasium | ||
5.4.a | The toilet room sign is not mounted in an accessible location and has no raised or Braille characters. | TR17 | 14 months |
5.4.b | The interior side of the door is inaccessible because it has an unbeveled threshold that is more than ¼ inch high. | D23 | 14 months |
5.4.c | No accessible mirror has been provided. | TR14 | 14 months |
5.4.d | The soap dispensers are inaccessible because they are mounted with the controls 52¼ inches above the finished floor behind the lavatories, and a front reach is required. | TR4 | 14 months |
5.4.e | The bottom of the lavatory apron is 27 ¾ inches above the finished floor, and its hot water pipes are not covered or configured to protect against contact. | TR9 | 14 months |
5.4.f | The urinal flush control is inaccessible because it is 45½ inches above the finished floor. | TR20 | 14 months |
5.4.g | The designated accessible toilet stall is inaccessible because it is 49½ inches wide. | ST16 | 14 months |
5.4.h | The toilet flush control is on the closed side. | ST2 | 14 months |
5.4.i | No accessible coat hook has been provided. | TR1 | 14 months |
5.4.j | The side grab bar at the toilet is inaccessible because it is obstructed by the toilet paper dispenser. | ST8 | 14 months |
6 | Damascus High School, 25921 Ridge Road, Damascus, Maryland 20872 | ||
6.1 | Parking | ||
6.1.a | No van accessible parking is provided. | P3 | 14 months |
6.2 | Girls' Locker Room | ||
6.2.a | The locker room sign is mounted above the doors and has no raised or Braille characters. | D26, TR17 | 14 months |
6.2.b | No accessible mirror has been provided. | TR14 | 14 months |
6.2.c | The lavatory pipes are not insulated or otherwise configured to protect against contact. | TR12 | 14 months |
6.2.d | No accessible coat hook has been provided in the designated accessible toilet stall. | TR1 | 14 months |
6.2.e | No accessible shower is provided. | B8 | 14 months |
6.2.f | The benches are inaccessible because they are 9½ inches wide and are not fixed to the wall. | LR1 | 14 months |
7 | Seneca Valley High School, 12700 Middlebrook Road, Germantown, Maryland 20874 | ||
7.1 | Parking | ||
7.1.a | There is no van accessible space provided, and the designated accessible spaces have no access aisles. | P3, P1 | 14 months |
7.2 | Ramp in Cafeteria | ||
7.2.a | The ramp is inaccessible because it has a slope of 9%, there are no handrail extensions at the top or bottom, the handrails are mounted 2 inches from the wall, and the handrail ends are not rounded or returned smoothly to the floor, wall, or post. | R4, R5 | 14 months |
7.3 | Girls' Locker Room | ||
7.3.a | The locker room sign is mounted above the door and has no raised or Braille characters. | D26, TR17 | 14 months |
7.3.b | There is a 4-inch step into the showers. | B7 | 14 months |
7.3.c | The benches are inaccessible because they are 10 inches wide and are not fixed to the wall. | LR1 | 14 months |
7.4 | Boys' Locker Room | ||
7.4.a | The locker room sign is mounted above the door and has no raised or Braille characters. | D26, TR17 | 14 months |
7.4.b | There is a 4-inch step into the showers. | B7 | 14 months |
7.4.c | The benches are inaccessible because they are 10 inches wide and are not fixed to the wall. | LR1 | 14 months |
7.5 | Single-User Unisex Toilet Room near Gym | ||
7.5.a | The threshold is inaccessible because it is more than ½ inch high. | D23 | 14 months |
7.5.b | The toilet centerline is 19¾ inches from the side wall. | SU15 | 14 months |
7.6 | Telephone near Gym | ||
7.6.a | The highest operable part of the telephone is 57 inches high. | TT1 | 14 months |
7.6.b | The telephone protrudes into the walkway and would not be detectable to a blind person using a cane. | AR8 | 14 months |
8 | Walter Johnson High School, 6400 Rock Spring Drive, Bethesda, Maryland 20814 | ||
8.1 | Parking | ||
8.1.a | Although the parking lot has a total of 486 parking spaces, it is inaccessible because there is no "van accessible" sign at the front van accessible space, 2 of the designated accessible spaces have no vertical sign, and one of the 9 required accessible spaces was blocked by a construction trailer at the time of our visit. | P6, P3 | 14 months |
8.2 | Entrance | ||
8.2.a | The entrance doors are inaccessible because they have an opening width of only 31 inches for each leaf. | D24 | 14 months |
8.3 | Interior ramp to cafeteria | ||
8.3.a | The ramp is inaccessible because it does not have handrails on both sides along the entire length of the ramp, the existing handrails are mounted too low, the inside handrail is not continuous, and the handrail does not have sufficient extensions on one side at the bottom. | R4 | 14 months |
8.4 | Men's Toilet Room with Stalls 171A | ||
8.4.a | The pressure required to open the door is 14 pounds. | D2 | 14 months |
8.5 | Women's Toilet Room with Stalls 171B | ||
8.5.a | The force required to open the door is 16 pounds. | D2 | 14 months |
8.5.b | The door has an inaccessible threshold. | D23 | 14 months |
8.5.c | The feminine products dispenser is inaccessible because it has controls that require twisting to operate. | TR3 | 14 months |
8.5.d | The grab bars at the toilet are mounted 37 inches above the finished floor. | ST12 | 14 months |
8.6 | Drinking Fountain by Lower Level Toilet Rooms | ||
8.6.a | Although an accessible drinking fountain is provided, there is no drinking fountain provided for people who have difficulty bending or stooping. | DF3 | 14 months |
9 | Rockville High School, 2100 Baltimore Road, Rockville, Maryland | ||
9.1 | Elevator | ||
9.1.a | The elevator is inaccessible because there is no hoistway signage. | E12 | 14 months |
9.2 | Ramp onto the 2nd level from elevator | ||
9.2.a | The ramp is inaccessible because the bottom section of the ramp has no handrails, the second section of the ramp has a slope ranging up to 8.8%, and the last section of the ramp has a handrail only on the left side. | R2, R3 | 14 months |
9.3 | Drinking Fountain by Women's Locker Room | ||
9.3.a | The drinking fountain protrudes 10 inches into the walkway at 33 ¾ inches above the finished floor and would not be detectable to a blind person using a cane. | AR8 | 14 months |
9.4 | Women's Locker Room | ||
9.4.a | The signage provided is inaccessible because there is no International Symbol of Accessibility. | D26 | 14 months |
9.4.b | The entrance door is inaccessible because the force required to open the door is greater than 5 pounds. | D2 | 14 months |
9.4.c | The long shelf protrudes into the walkway and would not be detectable to a blind person using a cane. | AR8 | 14 months |
9.4.d | No accessible mirror has been provided. | TR14 | 14 months |
9.4.e | The toilet is inaccessible because the top of the seat is 20 inches above the finished floor. | ST20 | 14 months |
9.4.f | The toilet is inaccessible because its centerline is 17 inches from the side wall. | ST17 | 14 months |
9.4.g | The rear grab bar at the toilet is inaccessible because it is 33 inches in length. | ST4 | 14 months |
9.4.h | No grab bars are provided in the transfer shower. | B9 | 14 months |
9.4.i | The shower is inaccessible because the shower spray unit must be hand-held. | B11 | 14 months |
9.4.j | The bench provided is 9 ½ inches wide and is not fixed to a wall. | LR1 | 14 months |
9.5 | Men's Locker Room | ||
9.5.a | The signage provided is inaccessible because there is no International Symbol of Accessibility. | D26 | 14 months |
9.5.b | The entrance door is inaccessible because the force required to open the door is greater than 5 pounds. | D2 | 14 months |
9.5.c | No accessible mirror has been provided. | TR14 | 14 months |
9.5.d | The urinal is inaccessible because the rim is 19 inches above the finished floor. | TR20 | 14 months |
9.5.e | No accessible toilet stall is provided. | ST15 | 14 months |
9.5.f | No grab bars are provided in the transfer shower. | B9 | 14 months |
9.5.g | The shower is inaccessible because the shower spray unit does not comply with the Standards. | B11 | 14 months |
9.5.h | The bench provided is 9 ½ inches wide and is not fixed to a wall. | LR1 | 14 months |
9.6 | Gym Entrance | ||
9.6.a | The main entrance door to the gym is inaccessible because the force required to open the door is greater than 5 pounds. | D2 | 14 months |
9.7 | Telephone by Gym | ||
9.7.a | The telephone by the gym is inaccessible because the highest operable part is 55 inches above the finished floor. | TT1 | 14 months |
10 | Gaithersburg High School, 314 South Frederick Avenue, Gaithersburg, Maryland | ||
10.1 | Parking | ||
10.1.a | Although there is one designated accessible space, there is no access aisle, van signage or clear markings. | P1, P6, P3 | 14 months |
10.2 | Parking Area to Cafeteria | ||
10.2.a | The route from the parking area to the cafeteria is inaccessible because there is an abrupt level change at the curb ramp, there are no detectable warnings, and the slope of the curb ramp is 10%. | AR1, AR5 | 14 months |
10.3 | Entrance to Cafeteria | ||
10.3.a | The door to the polling area is inaccessible because it has an opening width of only 31 ½ inches. | D25 | 14 months |
10.4 | Women's Toilet Room (stalls) near the cafeteria | ||
10.4.a | The toilet room contains a number of inaccessible elements and is not accessible to people with disabilities. | ST14 | 14 months |
10.5 | Men's Toilet Room (stalls) near the cafeteria | ||
10.5.a | The toilet room contains a number of inaccessible elements and is not accessible to people with disabilities. | ST14 | 14 months |
10.6 | Women's Toilet Room (stalls) near the auditorium | ||
10.6.a | The toilet room contains a number of inaccessible elements and is not accessible to people with disabilities. | ST14 | 14 months |
10.7 | Men's Toilet Room (stalls) near the auditorium | ||
10.7.a | The toilet room contains a number of inaccessible elements and is not accessible to people with disabilities. | ST14 | 14 months |