Attachment K

 

Existing Facilities

 

Please Note: Paragraph 49 of the Settlement Agreement requires that within one year of the effective date of this Agreement, the County provide signage as necessary to comply with 28 C.F.R. § 35.163(b), after having surveyed all facilities that are the subject of this Agreement for the purpose of identifying those that have multiple entrances not all of which are accessible.

 

In order to ensure that each of the County's programs, services, and activities operating at a facility that is the subject of this Agreement, when viewed in its entirety, are readily accessible to and usable by persons with mobility impairments, the County will take the following actions:

 

 

A.        It is agreed that in matters pertaining to accessible parking and the signage for same, the County may follow the New York State code requirements of providing all accessible spaces with a 96" access aisle, including the standard "Permit only - Handicapped Parking" sign with symbol, in lieu of providing the ADA prescribed 'Van Accessible' signage".

 

B.         Within 36 months of the effective date of the Agreement, the County will make the following modifications to the Children's Detention Center, located at 355 Westfall Road, Rochester, NY:

 

1.         The County has advised the Department that it intends to renovate this facility.  Within 12 months of the effective date of this Agreement, the County will submit for review by the Department a complete design and construction documentation, including construction drawings, project manuals, and addenda for the renovation.  The Department will review the documentation for conformity to the Standards, and the County will correct any and all non-compliant elements indicated in the construction documents prior to the start of the renovation and will build in compliance with the approved designs.  If the County does not renovate this facility, the following actions will be taken:

 

2.         Parking

a. The Circular Parking Area in Front of the Building

i. No curb cuts are provided.  Provide a curb ramp that is at least 36 inches wide, has a maximum slope of 1:12, is located so that it cannot be obstructed by parked vehicles, and has a stable, firm, and slip-resistant surface with a detectable warning extending the full width and depth of the ramp.  If the curb ramp is located where pedestrians must walk across it, provide either flared sides (with a maximum slope of 1:10) or handrails or guardrails to protect against cross traffic.  Standards § 4.3.8, 4.7, Fig. 12.

b. Parking Area Adjacent to the Side of the Building

i. The parking reserved for persons with disabilities is not located on the shortest accessible route to the accessible facility entrance.  Provide fully accessible parking that is located on the shortest accessible route to an accessible pedestrian entrance to the facility.  Standards § 4.6.2.

 

3.         Interior Offices, Dorms, and Program Access

a. The doors to many of the interior offices and facilities within the building use knob hardware.  Provide doors with hardware that is easy to grasp with one hand and that does not require tight grasping, pinching, or twisting of the wrist to operate.  Lever-operated mechanisms, push-type mechanisms, and U-shaped handles are acceptable designs.  Standards § 4.13.9.

b. Lockers in Visitors Area

i. The lockers require tight grasping, pinching or twisting of the wrist to operate.  Provide lockers with mechanical controls, if any, that can be operated with 5 lbf or less and that can be used with one hand and without tight grasping, pinching, or twisting of the wrist (lever-operated, push-type, and electronically controlled mechanisms are examples of acceptable designs).  Standards § 4.27.4.

c. Interview Rooms           

i. The doors to each of the three interview rooms is 29 ½ inches wide.  Provide a door with a clear opening of 32 inches with the door open 90 degrees, measured between the face of the door and the opposite stop.  Standards § 4.13.5, Fig. 24.

d. Girl's Dorm

i. The door is 29 ½ inches wide.  Provide a door with a clear opening of 32 inches with the door open 90 degrees, measured between the face of the door and the opposite stop.  Standards § 4.13.5, Fig. 24.

e. The Rec Yard

i. The entrance from the building to the rec yard is inaccessible because there is a 6 inch change in level at the threshold to the door.  Provide an accessible door with a threshold that is no greater than ¼ inch, or is no greater than ½ inch and is beveled with a slope no greater than 1:2.  Standards §§ 4.13.8, 4.5.2.

 

4.         Toilet Rooms

a. Men's Single-User Toilet Room

i. The single user toilet room contains a number of inaccessible elements and is not accessible to people with disabilities.  Provide an accessible toilet room such that all of the room's elements, including signage, door, door hardware, clear floor space, water closet, urinal (if provided), grab bars, lavatory, mirror, controls, and dispensers, comply with the Standards.  Standards §§ 4.13, 4.16, 4.18, 4.19, 4.26, 4.27, 4.30, Figs. 28, 29.

b. Women's Single-User Toilet Room

i. The single user toilet room contains a number of inaccessible elements and is not accessible to people with disabilities.  Provide an accessible toilet room such that all of the room's elements, including signage, door, door hardware, clear floor space, water closet, urinal (if provided), grab bars, lavatory, mirror, controls, and dispensers, comply with the Standards.  Standards §§ 4.13, 4.16, 4.18, 4.19, 4.26, 4.27, 4.30, Figs. 28, 29.

c. Unisex Dressing/Bathing/Toilet Room

i. The Toilet Room

(a) The toilet room contains a number of inaccessible elements and is not accessible to people with disabilities.  Provide an accessible toilet room such that all of the room's elements, including signage, door, door hardware, clear floor space, water closet, urinal (if provided), grab bars, lavatory, mirror, controls, and dispensers, comply with the Standards.  Standards §§ 4.13, 4.16, 4.18, 4.19, 4.26, 4.27, 4.30, Figs. 28, 29.

ii. The Bathing Room

(a) The bathtub contains a number of inaccessible elements.  Provide a bathtub that has a transfer seat securely mounted such that it does not slip during use; clear floor space that complies with Fig. 33; controls mounted below the grab bar at the foot of the tub, operable with one hand and without tight grasping, pinching, or twisting of the wrist, and requiring no more than 5 pounds of force to operate; an adjustable height shower spray unit mounted on a vertical bar with a hose at least 60 inches long that can be used both as a fixed shower head and as a hand-held shower; grab bars that comply with Fig. 34; and enclosures, if any, that do not obstruct bathtub controls or obstruct transfers from wheelchairs onto bathtub seats or into tubs and that do not have tracks mounted on their rims.  Standards § 4.20, Figs. 33, 34.

 

5.         Drinking Fountain

a. The drinking fountain is inaccessible to persons using wheelchairs.  Provide a drinking fountain with a spout height no higher than 36 inches, measured from the finished floor or ground surface to the spout outlet; and a spout located at the front of the unit that directs the water flow in a trajectory that is nearly parallel to the front of the unit and is positioned so the flow of water is within 3 inches of the front edge of the fountain and at least 4 inches high.  Ensure that fountain controls are operable with one hand, require 5 lbf or less to operate without tight grasping, pinching, or twisting of the wrist; and are front mounted or side mounted near the front edge.  For each accessible drinking fountain, provide a drinking fountain that is accessible to people who have difficulty bending or stooping.  This can be accommodated by the use of a "hi-lo" fountain; by providing one fountain accessible to those who use wheelchairs and one fountain at a standard height convenient for those who have difficulty bending; by providing a fountain accessible to people who use wheelchairs and a cup dispenser; or by such other means as would achieve the required accessibility for each group of people.  Standards §§ 4.15, 4.27.4, Fig. 27.

 

 

C.        Within 12 months of the effective date of the Agreement, the County will make the following modifications to the Medical Examiner's Office, located at 740 East Henrietta Road, Rochester, NY:

 

1.         Parking

a. Although there are 12 parking spaces with 2 designated as reserved for persons with disabilities, the demarcation of the spaces designated as reserved for persons with disabilities is faint.  On the shortest accessible route to the accessible entrance, provide 1 van accessible space and 1 standard space designated as reserved for people with disabilities.  Ensure that standard accessible spaces are a minimum of 96 inches wide and served by access aisles at least 60 inches wide.  Ensure that van accessible spaces are a minimum of 96 inches wide and served by access aisles at least 96 inches wide.  At all spaces designated as reserved for persons with disabilities, provide vertical signs with the International Symbol of Accessibility located such that they cannot be obstructed by parked vehicles.  At van accessible spaces, provide an additional "Van-Accessible" sign located below the International Symbol of Accessibility.  Ensure that all spaces and access aisles for persons with disabilities are flat and level, with slopes and cross-slopes not exceeding 1:50 in all directions, and that their surfaces are firm, stable, and slip-resistant.  Standards §§ 4.1.2(5), 4.6, 4.30.7(1).

 

2.         Office and Counters

a. Community Room

i. The call button is 58 inches above the finished floor. Provide a call button within accessible reach ranges at this entrance and ensure that the door will be unlocked promptly when the call button is used.  Standards § 4.1.3(8).

ii. The pressure required to open the door is 6 pounds of force.  Provide a door that requires no more than 5 pounds of force to open.  Standards § 4.13.11(2)(b).

b. Observation Room

i. The pressure required to open the door is 8 pounds of force.  Provide a door that requires no more than 5 pounds of force to open.  Standards § 4.13.11(2)(b).

 

3.         Single-User Toilet Rooms

a. Women's

i. The toilet room sign lacks the International Symbol of Access and raised and Braille letters.  Provide a toilet room sign with raised and Braille characters.  The sign shall be mounted on the wall adjacent to the latch side of the door with the centerline of the sign at 60 inches above the finished floor and situated such that a person can approach within 3 inches of the sign without encountering an obstruction or standing within a door swing.  Standards §§ 4.1.2(7)(d), 4.30.1, 4.30.4, 4.30.5, 4.30.6.

ii. The pressure required to open the door exceeds 5 pounds of force.  Provide a door that requires no more than 5 pounds of force to open.  Standards § 4.13.11(2)(b).

iii. No accessible coat hook has been provided.  Provide a coat hook at a maximum height above the finished floor of 48 inches for a forward approach or 54 inches for a side approach and that is accompanied by clear floor space of 30 by 48 inches that allows a forward or parallel approach by a person using a wheelchair.  Standards §§ 4.25.2, 4.25.3, 4.2.4, 4.2.5, 4.2.6.

iv. The toilet centerline is 23 inches from the side wall.  Provide a toilet with a centerline that measures 18 inches from the near side wall.  Standards § 4.16.2, Fig. 28.

v. The flush control valve is on the closed side.  Provide a flush control mounted on the "open" side of the toilet's clear floor space; 44 inches or less above the finished floor; and requiring a maximum of 5 pounds of force to operate; or provide an automatic flush device.  Standards §§ 4.16.5, 4.27.4.

b. Men's

i. The toilet room sign lacks the International Symbol of Access and raised and Braille letters.  Provide a toilet room sign with raised and Braille characters.  The sign shall be mounted on the wall adjacent to the latch side of the door with the centerline of the sign at 60 inches above the finished floor and situated such that a person can approach within 3 inches of the sign without encountering an obstruction or standing within a door swing.  Standards §§ 4.1.2(7)(d), 4.30.1, 4.30.4, 4.30.5, 4.30.6.

ii. The pressure required to open the door exceeds 5 pounds of force.  Provide a door that requires no more than 5 pounds of force to open.  Standards § 4.13.11(2)(b).

iii. No accessible coat hook has been provided.  Provide a coat hook at a maximum height above the finished floor of 48 inches for a forward approach or 54 inches for a side approach and that is accompanied by clear floor space of 30 by 48 inches that allows a forward or parallel approach by a person using a wheelchair.  Standards §§ 4.25.2, 4.25.3, 4.2.4, 4.2.5, 4.2.6.

iv. The toilet centerline is 19 inches from the side wall.  Provide a toilet with a centerline that measures 18 inches from the near side wall.  Standards § 4.16.2, Fig. 28.

v. The top of the toilet seat is 16 ¼ inches above the finished floor.  Provide a toilet with a seat that measures 17 to 19 inches above the finished floor.  Standards § 4.16.3, Fig. 29(b).

 

 

D.        Within 12  months of the effective date of the Agreement, the County will make the following modifications to the County Correctional Facility, located at 750 East Henrietta Road, Rochester, NY:

 

1.         Lobby

a. Drinking Fountain

i. Although an accessible drinking fountain is provided, there is no drinking fountain provided for people who have difficulty bending or stooping.  Provide a drinking fountain that is accessible to people who have difficulty bending or stooping.  This can be accommodated by the use of a "hi-lo" fountain; by providing one fountain accessible to those who use wheelchairs and one fountain at a standard height convenient for those who have difficulty bending; by providing a fountain accessible to people who use wheelchairs and a cup dispenser, or by such other means as would achieve the required accessibility for each group of people.  Standards §§ 4.1.3(10)(a), 4.1.6(1)(b).

b. Telephone

i. Although a public telephone is provided, there is no signage and no lower phone accessible to persons using wheelchairs.  Provide an accessible telephone with a clear floor space of at least 30 inches by 48 inches that allows either a forward or parallel approach by a person using a wheelchair such that bases, enclosures, and fixed seats do not impede approaches to the telephone; with the highest operable part of the telephone mounted no more than 48 inches above the floor for a front approach or no more than 54 inches above the floor for a side approach; that is hearing aid compatible and has a volume control mechanism; with telephone books, if provided, located between 15 and 48 inches above the finished floor for a front approach or between 9 and 54 inches above the finished floor for a side approach; with a cord of at least 29 inches long from the telephone to the handset; and with signage that complies with the Standards.  Standards §§ 4.1.3(17), 4.1.6(1)(b), 4.31, 4.30.7(2), 4.1.3(17)©), 4.1.6(1)(b), 4.30.7(3), 4.31.9.

 

2.         Housing Units

a. In both the A Mod and the B Mod, there are no accessible toilets, urinals, lavatories, or showers.  For each type of Housing Unit (depending on gender, level of security, etc.), ensure that at least one has an accessible toilet, lavatory, shower, bench, fixed seating (if provided) and other elements that comply with the Standards as outlined below, or provide a program access solution within the pre-trial units at the County Jail.

 

 

E.         Within 24 months of the effective date of the Agreement, the County will make the following modifications to the Churchville Park, located at North Main Street .

 

1.         Golf Course/Clubhouse

a. Parking

i. The parking lot adjacent to the golf course/clubhouse requires an additional accessible space and two of the designated accessible spaces lack 60 inch access aisles.  On the shortest accessible route to the accessible entrance, provide one standard space designated as reserved for people with disabilities.  Standard accessible spaces shall be a minimum of 96 inches wide and served by access aisles at least 60 inches wide.  Van accessible spaces shall be a minimum of 96 inches wide and served by access aisles at least 96 inches wide.  All spaces designated as reserved for people with disabilities shall have vertical signs with the International Symbol of Accessibility located such that they cannot be obstructed by parked vehicles.   Standards §§ 4.1.2(5), 4.6, 4.30.7(1).

 

b. Accessible Route and Entrance

i. The route from the parking lot to the clubhouse has a 3/4 inch lip and is broken in places.  Provide at least one accessible route within the boundary of the site connecting these elements that, to the maximum extent feasible, coincides with the route for the general public.  The accessible route must have a minimum clear width of 36 inches, or a minimum clear width of 42 inches if there is a turn around an obstruction less than 48 inches wide; have passing spaces at least 60 inches by 60 inches at least every 200 feet; have a minimum clear headroom of 80 inches; have a surface that is firm, stable, and slip resistant; have, in the absence of a curb ramp, ramp, elevator, or platform lift, no level changes in excess of ½ inch vertically; and have a running slope of less than 1:20 (5%) (or have been constructed as a fully accessible ramp) and a cross slope of less than 1:50 (2%).  Standards §§ 4.3, 4.5, Fig. 7.

ii. The clubhouse screen door has a clear opening width of 28 inches.  Provide a door with a clear opening of 32 inches with the door open 90 degrees, measured between the face of the door and the opposite stop.  Standards § 4.13.5, Fig. 24.  Alternatively, the County will provide an alternate accessible route and will provide appropriate signage.

 

c. Men's and Women's Single-User Toilet Rooms- Church lodge, exterior have many barriers to access by persons with disabilities.  As a program access solution, the County  will retrofit the East/West Lodge, and in the interim will provide signage indicating provide signage indicating that persons with disabilities should use the accessible toilet rooms at the Clubhouse.  The Clubhouse toilet rooms will be kept unlocked during all hours the exterior toilet rooms would be used.

 

d. Men's Toilet Room w/ Stalls- Golf Clubhouse, Golf shop

i. The toilet room lacks accessible signage.  Provide a toilet room sign with raised and Braille characters.  The sign shall be mounted on the wall adjacent to the latch side of the door with the centerline of the sign at 60 inches above the finished floor and situated such that a person can approach within 3 inches of the sign without encountering an obstruction or standing within a door swing.  Standards §§ 4.1.2(7)(d), 4.30.1, 4.30.4, 4.30.5, 4.30.6.

ii. The toilet room door has knob hardware that requires tight grasping, pinching, or twisting of the wrist to operate.  Provide a door with hardware usable with one hand and without tight grasping, pinching, or twisting of the wrist.  Lever-operated, push-type, and U-shaped handles are acceptable designs.  Standards § 4.13.9.

iii. The mirror is inaccessible.  Provide a mirror with the bottom edge of its reflecting surface no more than 40 inches above the finished floor.  Standards § 4.19.6. 

iv. The soap dispenser is mounted 47 inches above the floor and requires a reach over a 20 inch obstruction to operate.  Provide a soap dispenser such that the controls comply with Fig. 5 for a forward reach or with Fig. 6 for a side reach and such that it is accompanied by clear floor space of 30 by 48 inches that allows a forward or parallel approach, respectively, by a person using a wheelchair.  Standards §§ 4.27.2, 4.27.3, 4.2.4, 4.2.5, 4.2.6.

v. The lavatory hot water pipes are not insulated or otherwise configured to protect against contact.  Provide hot water and drain pipes that are insulated or otherwise configured to protect against contact.  Standards § 4.19.4.

vi. The toilet is inaccessible because there is insufficient clear floor space.  Provide clear floor space that complies with Fig. 30 at the toilet.  Standards § 4.17.3, Fig. 30.

vii. The toilet height is 15 ½ inches above the finished floor.  Provide a toilet with a seat that measures 17 to 19 inches above the finished floor.  Standards §§ 4.16.3, 4.17.2, Fig. 30(d).

viii. The toilet centerline measures 26 ½ inches above the finished floor.  Provide a toilet with a centerline that measures 18 inches from the near side wall.  Standards § 4.17.3, Fig. 30.

ix. The side grab bar is mounted 40 ½ inches above the finished floor.  Provide grab bars that are mounted between 33 and 36 inches above the finished floor.  Standards § 4.17.6, Fig. 30.

x. The bench provided is inaccessible and not fixed in place.  Provide a 24 inch by 48 inch bench fixed to the wall along the bench's longer dimension.  Ensure that the bench has sufficient structural strength and is mounted with its surface between 17 inches and 19 inches above the finished floor.  Provide clear floor space alongside the bench to allow a person using a wheelchair to make a parallel transfer onto the bench.  Standards §§ 4.35.4, 4.26.3.

e. Women's Toilet Room w/ Stalls- Golf Clubhouse, Golf shop

i. The toilet room lacks accessible signage.  Provide a toilet room sign with raised and Braille characters.  The sign shall be mounted on the wall adjacent to the latch side of the door with the centerline of the sign at 60 inches above the finished floor and situated such that a person can approach within 3 inches of the sign without encountering an obstruction or standing within a door swing.  Standards §§ 4.1.2(7)(d), 4.30.1, 4.30.4, 4.30.5, 4.30.6.

ii. The clear opening width of the toilet room door measures 28 inches.  Provide a door with a clear opening of 32 inches with the door open 90 degrees, measured between the face of the door and the opposite stop.  Standards § 4.13.5, Fig. 24.

iii. The toilet room door has knob hardware that requires tight grasping, pinching, or twisting of the wrist to operate.  Provide a door with hardware usable with one hand and without tight grasping, pinching, or twisting of the wrist.  Lever-operated, push-type, and U-shaped handles are acceptable designs.  Standards § 4.13.9.

iv. The toilet room door has a threshold that measures 2 1/4 inches in height.  Provide a door with a threshold no greater than ¼ inch, or between ¼ inch and ½ inch and beveled with a slope no greater than 1:2.  Standards §§ 4.13.8, 4.5.2.

v. The path of travel into the toilet room is obstructed by a 3/4 inch lip on the path.  Provide an accessible route to the toilet room with required minimum width, passing space, head room, surface textures, slopes, and changes in level.  Standards §§ 4.3.1, 4.3.2, 4.3.3, 4.3.4, 4.3.5, 4.3.6, 4.3.7, 4.3.8.

vi. The mirror is inaccessible.  Provide a mirror with the bottom edge of its reflecting surface no more than 40 inches above the finished floor.  Standards § 4.19.6.

vii. The soap dispenser is mounted 45 inches above the finished floor and requires a reach over a 20 inch obstruction to operate.  Provide a soap dispenser such that the controls comply with Fig. 5 for a forward reach or with Fig. 6 for a side reach and such that it is accompanied by clear floor space of 30 by 48 inches that allows a forward or parallel approach, respectively, by a person using a wheelchair.  Standards §§ 4.27.2, 4.27.3, 4.2.4, 4.2.5, 4.2.6.

viii. The lavatory hot water pipes are not insulated or otherwise configured to protect against contact.  Provide hot water and drain pipes that are insulated or otherwise configured to protect against contact.  Standards § 4.19.4.

ix. The lavatory faucet has knob style hardware that requires tight grasping, pinching or twisting of the wrist to operate.  Provide a lavatory with a faucet that can be operated with 5 pounds of force or less and can be used with one hand and without tight grasping, pinching, or twisting of the wrist (lever-operated, push-type, and electronically controlled mechanisms are examples of acceptable designs).  Standards §§ 4.19.5, 4.27.4.

x. The accessible stall lacks clear floor space required to use the toilet.  Provide a toilet stall that is at least 60 inches wide and at least 56 inches deep for a wall-mounted toilet or at least 59 inches deep for a floor-mounted toilet, such that the centerline of the toilet is exactly 18 inches from the near side wall or partition, and there is at least 9 inches of toe clearance above the floor at the front partition if the stall is no more than 60 inches deep.  Standards § 4.17, Fig. 30.

xi. The toilet height measures 16 inches above the finished floor.  Provide a toilet with a seat that measures 17 to 19 inches above the finished floor.  Standards §§ 4.16.3, 4.17.2, Fig. 30(d).

xii. The toilet centerline measures 17 inches from the side wall.  Provide a toilet with a centerline that measures 18 inches from the near side wall.  Standards § 4.17.3, Fig. 30.

xiii. The toilet paper dispenser is inaccessible.  Provide a toilet paper dispenser that is mounted with its top at least 1½ inches under the side grab bar and 36 inches or less from the rear wall and is centered at least 19 inches above the finished floor.  Standards § 4.17.3, Fig. 30(d).

xiv. There is no side grab bar provided.  Provide a side grab bar that is at least 40 inches in overall length, with the far end mounted at least 52 inches from the rear wall and the closer end 12 inches or less from the rear wall; mounted 33 to 36 inches above the finished floor; with a diameter between 1¼ and 1½ inches; with 1½ inches between the grab bar and the wall; and at least 1½ inches between the grab bar and any other object, such as the toilet paper dispenser.  Standards §§ 4.17.6, 4.26.2, Figs. 30(a), (d).

xv. There is no rear grab bar provided.  Provide a rear grab bar that is at least 36 inches in overall length, with the closer end no more than 6 inches from the side wall; mounted 33 to 36 inches above the finished floor; with a diameter between 1¼ and 1½ inches; with 1½ inches between the grab bar and the wall; and at least 1½ inches between the grab bar and any other object, such as a toilet seat cover dispenser.  Standards §§ 4.17.6, 4.26.2, Fig. 30.

 

2.         Hickory Grove

a. Parking

i. This area of the park lacks spaces designated as reserved for persons with disabilities.  On the shortest accessible route to the accessible entrance, provide 1 van accessible space designated as reserved for people with disabilities.  Ensure that van accessible spaces are a minimum of 96 inches wide and served by access aisles at least 96 inches wide.  At all spaces designated as reserved for persons with disabilities, provide vertical signs with the International Symbol of Accessibility located such that they cannot be obstructed by parked vehicles.  At van accessible spaces, provide an additional "Van-Accessible" sign located below the International Symbol of Accessibility.  Ensure that all spaces and access aisles for persons with disabilities are flat and level, with slopes and cross-slopes not exceeding 1:50 in all directions, and that their surfaces are firm, stable, and slip-resistant.  Standards §§ 4.1.2(5), 4.6, 4.30.7(1).

 

b. Toilet Room with Stalls

i. Men's

(a) The path of travel is over grass, has a cross slope and, as such, there is no accessible route to the toilet room.  Provide at least one accessible route within the boundary of the site connecting these elements that, to the maximum extent feasible, coincides with the route for the general public.  The accessible route must have a minimum clear width of 36 inches, or a minimum clear width of 42 inches if there is a turn around an obstruction less than 48 inches wide; have passing spaces at least 60 inches by 60 inches at least every 200 feet; have a minimum clear headroom of 80 inches; have a surface that is firm, stable, and slip resistant; have, in the absence of a curb ramp, ramp, elevator, or platform lift, no level changes in excess of ½ inch vertically; and have a running slope of less than 1:20 (5%) (or have been constructed as a fully accessible ramp) and a cross slope of less than 1:50 (2%).  Standards §§ 4.3, 4.5, Fig. 7.

(b) The toilet room lacks an accessible sign.  Provide a toilet room sign with raised and Braille characters.  The sign shall be mounted on the wall adjacent to the latch side of the door with the centerline of the sign at 60 inches above the finished floor and situated such that a person can approach within 3 inches of the sign without encountering an obstruction or standing within a door swing.  Standards §§ 4.1.2(7)(d), 4.30.1, 4.30.4, 4.30.5, 4.30.6.

(c) The threshold at the door is cracked and has gaps that make it inaccessible.  Provide a door with a threshold no greater than ¼ inch, or between ¼ inch and ½ inch and beveled with a slope no greater than 1:2.  Standards §§ 4.13.8, 4.5.2.

(d) The urinal rim is 27 inches and the flush control valve is 48 inches above the finished floor.  Provide a urinal with an elongated rim mounted 17 inches or less above the finished floor, a clear floor space of at least 30 inches wide and 48 inches deep centered on the urinal, and a flush control height of 44 inches or less above the finished floor.  Standards §§ 4.18.2, 4.18.3, 4.18.4.

(e) There is no accessible stall provided.  Provide a "standard" accessible toilet stall at least 60 inches wide and at least 59 inches deep (or at least 56 inches deep with a wall-mounted toilet) such that all of the stall's elements, including stall door, stall door hardware, water closet, size and arrangement, toe clearances, grab bars, controls, and dispensers, comply with the Standards.  Standards §§ 4.13, 4.16, 4.17, 4.26, 4.27, Fig. 30.

ii. Women's

(a) The path of travel is over grass, has a cross slope and, as such, there is no accessible route to the toilet room.  Provide at least one accessible route within the boundary of the site connecting these elements that, to the maximum extent feasible, coincides with the route for the general public.  The accessible route must have a minimum clear width of 36 inches, or a minimum clear width of 42 inches if there is a turn around an obstruction less than 48 inches wide; have passing spaces at least 60 inches by 60 inches at least every 200 feet; have a minimum clear headroom of 80 inches; have a surface that is firm, stable, and slip resistant; have, in the absence of a curb ramp, ramp, elevator, or platform lift, no level changes in excess of ½ inch vertically; and have a running slope of less than 1:20 (5%) (or have been constructed as a fully accessible ramp) and a cross slope of less than 1:50 (2%).  Standards §§ 4.3, 4.5, Fig. 7.

(b) The toilet room lacks an accessible sign.  Provide a toilet room sign with raised and Braille characters.  The sign shall be mounted on the wall adjacent to the latch side of the door with the centerline of the sign at 60 inches above the finished floor and situated such that a person can approach within 3 inches of the sign without encountering an obstruction or standing within a door swing.  Standards §§ 4.1.2(7)(d), 4.30.1, 4.30.4, 4.30.5, 4.30.6.

(c) The threshold at the door is cracked and has gaps that make it inaccessible.  Provide a door with a threshold no greater than ¼ inch, or between ¼ inch and ½ inch and beveled with a slope no greater than 1:2.  Standards §§ 4.13.8, 4.5.2.

(d) There is no accessible stall provided.  Provide a "standard" accessible toilet stall at least 60 inches wide and at least 59 inches deep (or at least 56 inches deep with a wall-mounted toilet) such that all of the stall's elements, including stall door, stall door hardware, water closet, size and arrangement, toe clearances, grab bars, controls, and dispensers, comply with the Standards.  Standards §§ 4.13, 4.16, 4.17, 4.26, 4.27, Fig. 30.

c. Picnic Shelter

i. The path of travel is over grass and, as such, there is no accessible route to the picnic shelter.  Provide at least one accessible route within the boundary of the site connecting these elements that, to the maximum extent feasible, coincides with the route for the general public.  The accessible route must have a minimum clear width of 36 inches, or a minimum clear width of 42 inches if there is a turn around an obstruction less than 48 inches wide; have passing spaces at least 60 inches by 60 inches at least every 200 feet; have a minimum clear headroom of 80 inches; have a surface that is firm, stable, and slip resistant; have, in the absence of a curb ramp, ramp, elevator, or platform lift, no level changes in excess of ½ inch vertically; and have a running slope of less than 1:20 (5%) (or have been constructed as a fully accessible ramp) and a cross slope of less than 1:50 (2%).  Standards §§ 4.3, 4.5, Fig. 7.

ii. The picnic tables are inaccessible to persons using wheelchairs.  Provide at least one picnic table on an accessible route such that there is knee space at the table at least 27 inches high, 30 inches wide, and 19 inches deep, and such that the height of the top of the table is between 28 inches and 34 inches above the ground.  Standards §§ 4.32.3, 4.32.4.

 

F.         Within 36 months of the effective date of the Agreement, the County will make the following modifications to the Northampton Park, located at Colby Street, Rochester, NY:

 

1.         Parking - Ski Lodge

a. Although there are 60 parking spaces with 2 designated as reserved for persons with disabilities, the spaces lack numerous elements needed to be accessible.  On the shortest accessible route to the accessible entrance, provide 1 van accessible space and 2 standard spaces designated as reserved for people with disabilities.  Standard accessible spaces shall be a minimum of 96 inches wide and served by access aisles at least 60 inches wide.  Van accessible spaces shall be a minimum of 96 inches wide and served by access aisles at least 96 inches wide.  All spaces designated as reserved for people with disabilities shall have vertical signs with the International Symbol of Accessibility located such that they cannot be obstructed by parked vehicles.  Van accessible spaces shall have an additional "Van-Accessible" sign located below the International Symbol of Accessibility.  Standards §§ 4.1.2(5), 4.1.6(1)(b), 4.6, 4.30.7(1).

 

2.         Exterior Entrance and Doors

a. All 3 exterior entrances have 1 ½ inch thresholds.  Provide at least one door with a threshold no greater than ¼ inch, or between ¼ inch and ½ inch and beveled with a slope no greater than 1:2.  Standards §§ 4.1.3(7)(b), 4.1.6(1)(b), 4.13.8, 4.5.2.

b. The exterior doors have knob hardware that require tight grasping, pinching or twisting of the wrist to operate.  Provide doors with hardware that is easy to grasp with one hand and that does not require tight grasping, pinching, or twisting of the wrist to operate.  Lever-operated mechanisms, push-type mechanisms, and U-shaped handles are acceptable designs.  Standards §§ 4.1.3(7)(b), 4.1.6(1)(b),

 

3.         Parking- Rodwell House

a. First Lot

i. Although there are 5 unmarked parking spaces, there is no space designated as reserved for people with disabilities.  On the shortest accessible route to the accessible entrance, provide 1 van accessible space designated as reserved for people with disabilities.  Ensure that van accessible spaces are a minimum of 96 inches wide and served by access aisles at least 96 inches wide.  At all spaces designated as reserved for persons with disabilities, provide vertical signs with the International Symbol of Accessibility located such that they cannot be obstructed by parked vehicles.  At van accessible spaces, provide an additional "Van-Accessible" sign located below the International Symbol of Accessibility.  Ensure that all spaces and access aisles for persons with disabilities are flat and level, with slopes and cross-slopes not exceeding 1:50 in all directions, and that their surfaces are firm, stable, and slip-resistant.  Standards §§ 4.1.2(5), 4.1.6(1)(b), 4.6, 4.30.7(1).

b. Second Lot

i. Although there are 5 unmarked parking spaces, with one space designated as reserved for people with disabilities, the space lacks several elements necessary to be accessible.  On the shortest accessible route to the accessible entrance, provide 1 van accessible space designated as reserved for people with disabilities.  Ensure that van accessible spaces are a minimum of 96 inches wide and served by access aisles at least 96 inches wide.  At all spaces designated as reserved for persons with disabilities, provide vertical signs with the International Symbol of Accessibility located such that they cannot be obstructed by parked vehicles.  At van accessible spaces, provide an additional "Van-Accessible" sign located below the International Symbol of Accessibility.  Ensure that all spaces and access aisles for persons with disabilities are flat and level, with slopes and cross-slopes not exceeding 1:50 in all directions, and that their surfaces are firm, stable, and slip-resistant.  Standards §§ 4.1.2(5), 4.1.6(1)(b), 4.6, 4.30.7(1).

 

4.         Parking- Knollwood

a. Although there are 30 unmarked parking spaces with two designated as reserved for people with disabilities, the spaces lack numerous elements needed to be accessible.  On the shortest accessible route to the accessible entrance, provide 1 van accessible space and 1 standard space designated as reserved for people with disabilities.  Standard accessible spaces shall be a minimum of 96 inches wide and served by access aisles at least 60 inches wide.  Van accessible spaces shall be a minimum of 96 inches wide and served by access aisles at least 96 inches wide.  All spaces designated as reserved for people with disabilities shall have vertical signs with the International Symbol of Accessibility located such that they cannot be obstructed by parked vehicles.  Van accessible spaces shall have an additional "Van-Accessible" sign located below the International Symbol of Accessibility.  Standards §§ 4.1.2(5), 4.1.6(1)(b), 4.6, 4.30.7(1).

 

5.         Men's Toilet Room w/ Stalls (Ski Lodge)

a. There is no accessible route from the parking lot to the toilet room.  Provide at least one accessible route within the boundary of the site connecting these elements that, to the maximum extent feasible, coincides with the route for the general public.  The accessible route must have a minimum clear width of 36 inches, or a minimum clear width of 42 inches if there is a turn around an obstruction less than 48 inches wide; have passing spaces at least 60 inches by 60 inches at least every 200 feet; have a minimum clear headroom of 80 inches; have a surface that is firm, stable, and slip resistant; have, in the absence of a curb ramp, ramp, elevator, or platform lift, no level changes in excess of ½ inch vertically; and have a running slope of less than 1:20 (5%) (or have been constructed as a fully accessible ramp) and a cross slope of less than 1:50 (2%).  Standards §§ 4.1.3(1), 4.1.6(1)(b), 4.3, 4.5, Fig. 7.

b. The toilet room lacks accessible signage.  Provide a toilet room sign with raised and Braille characters.  The sign shall be mounted on the wall adjacent to the latch side of the door with the centerline of the sign at 60 inches above the finished floor and situated such that a person can approach within 3 inches of the sign without encountering an obstruction or standing within a door swing.  Standards §§ 4.1.2(7)(d), 4.1.6(1)(b), 4.30.1, 4.30.4, 4.30.5, 4.30.6.

c. The toilet room door has knob hardware that requires tight grasping, pinching, or twisting of the wrist to operate.  Provide a door with a clear opening at least 32 inches wide when measured from the face of the door to the opposite stop when the door is opened 90 degrees and with hardware usable with one hand and without tight grasping, pinching, or twisting of the wrist.  Lever-operated, push-type, and U-shaped handles are acceptable designs.  Standards §§ 4.1.3(11), 4.1.6(1)(b), 4.22.2, 4.13.5, 4.13.9.

d. There is an 11 inch step on the path of travel into the toilet room.  Provide at least one accessible route within the boundary of the site connecting these elements that, to the maximum extent feasible, coincides with the route for the general public.  The accessible route must have a minimum clear width of 36 inches, or a minimum clear width of 42 inches if there is a turn around an obstruction less than 48 inches wide; have passing spaces at least 60 inches by 60 inches at least every 200 feet; have a minimum clear headroom of 80 inches; have a surface that is firm, stable, and slip resistant; have, in the absence of a curb ramp, ramp, elevator, or platform lift, no level changes in excess of ½ inch vertically; and have a running slope of less than 1:20 (5%) (or have been constructed as a fully accessible ramp) and a cross slope of less than 1:50 (2%).  Standards §§ 4.1.3(1), 4.1.6(1)(b), 4.3, 4.5, Fig. 7.

e. The soap dispenser is mounted 43 inches above the finished floor and requires a reach over a 20 inch obstruction.  Provide a soap dispenser such that the controls comply with Fig. 5 for a forward reach or with Fig. 6 for a side reach and such that it is accompanied by clear floor space of 30 by 48 inches that allows a forward or parallel approach, respectively, by a person using a wheelchair.  Standards §§ 4.1.3(13), 4.1.6(1)(b), 4.27.2, 4.27.3, 4.2.4, 4.2.5, 4.2.6.

f. There is no accessible stall provided.  Provide a "standard" accessible toilet stall at least 60 inches wide and at least 59 inches deep (or at least 56 inches deep with a wall-mounted toilet) such that all of the stall's elements, including stall door, stall door hardware, water closet, size and arrangement, toe clearances, grab bars, controls, and dispensers, comply with the Standards.  Standards §§ 4.1.3(11), 4.1.6(1)(b), 4.22.4, 4.22.7, 4.13, 4.16, 4.17, 4.26, 4.27, Fig. 30.

 

6.         Women's Toilet Room w/ Stalls (Ski Lodge)

a. There is no accessible route from the parking lot to the toilet room.  Provide at least one accessible route within the boundary of the site connecting these elements that, to the maximum extent feasible, coincides with the route for the general public.  The accessible route must have a minimum clear width of 36 inches, or a minimum clear width of 42 inches if there is a turn around an obstruction less than 48 inches wide; have passing spaces at least 60 inches by 60 inches at least every 200 feet; have a minimum clear headroom of 80 inches; have a surface that is firm, stable, and slip resistant; have, in the absence of a curb ramp, ramp, elevator, or platform lift, no level changes in excess of ½ inch vertically; and have a running slope of less than 1:20 (5%) (or have been constructed as a fully accessible ramp) and a cross slope of less than 1:50 (2%).  Standards §§ 4.1.3(1), 4.1.6(1)(b), 4.3, 4.5, Fig. 7.

b. The toilet room lacks accessible signage.  Provide a toilet room sign with raised and Braille characters.  The sign shall be mounted on the wall adjacent to the latch side of the door with the centerline of the sign at 60 inches above the finished floor and situated such that a person can approach within 3 inches of the sign without encountering an obstruction or standing within a door swing.  Standards §§ 4.1.2(7)(d), 4.1.6(1)(b), 4.30.1, 4.30.4, 4.30.5, 4.30.6.

c. The toilet room door has knob hardware that requires tight grasping, pinching, or twisting of the wrist to operate.  Provide a door with a clear opening at least 32 inches wide when measured from the face of the door to the opposite stop when the door is opened 90 degrees and with hardware usable with one hand and without tight grasping, pinching, or twisting of the wrist.  Lever-operated, push-type, and U-shaped handles are acceptable designs.  Standards §§ 4.1.3(11), 4.1.6(1)(b), 4.22.2, 4.13.5, 4.13.9.

d. There is a 7  inch step on the path of travel into the toilet room.  Provide at least one accessible route within the boundary of the site connecting these elements that, to the maximum extent feasible, coincides with the route for the general public.  The accessible route must have a minimum clear width of 36 inches, or a minimum clear width of 42 inches if there is a turn around an obstruction less than 48 inches wide; have passing spaces at least 60 inches by 60 inches at least every 200 feet; have a minimum clear headroom of 80 inches; have a surface that is firm, stable, and slip resistant; have, in the absence of a curb ramp, ramp, elevator, or platform lift, no level changes in excess of ½ inch vertically; and have a running slope of less than 1:20 (5%) (or have been constructed as a fully accessible ramp) and a cross slope of less than 1:50 (2%).  Standards §§ 4.1.3(1), 4.1.6(1)(b), 4.3, 4.5, Fig. 7.

e. The soap dispenser is mounted 43 inches above the finished floor and requires a reach over a 20 inch obstruction.  Provide a soap dispenser such that the controls comply with Fig. 5 for a forward reach or with Fig. 6 for a side reach and such that it is accompanied by clear floor space of 30 by 48 inches that allows a forward or parallel approach, respectively, by a person using a wheelchair.  Standards §§ 4.1.3(13), 4.1.6(1)(b), 4.27.2, 4.27.3, 4.2.4, 4.2.5, 4.2.6.

f. There is no accessible stall provided.  Provide a "standard" accessible toilet stall at least 60 inches wide and at least 59 inches deep (or at least 56 inches deep with a wall-mounted toilet) such that all of the stall's elements, including stall door, stall door hardware, water closet, size and arrangement, toe clearances, grab bars, controls, and dispensers, comply with the Standards.  Standards §§ 4.1.3(11), 4.1.6(1)(b), 4.22.4, 4.22.7, 4.13, 4.16, 4.17, 4.26, 4.27, Fig. 30.

 

7.         Large, Unisex, Single-User Toilet Room (Rodwell House)

a. The toilet room lacks an accessible sign.  Provide a toilet room sign with raised and Braille characters.  The sign shall be mounted on the wall adjacent to the latch side of the door with the centerline of the sign at 60 inches above the finished floor and situated such that a person can approach within 3 inches of the sign without encountering an obstruction or standing within a door swing.  Standards §§ 4.1.2(7)(d), 4.1.6(1)(b), 4.30.1, 4.30.4, 4.30.5, 4.30.6.

b. No accessible mirror has been provided.  Provide a mirror with the bottom edge of its reflecting surface no more than 40 inches above the finished floor.  Standards §§ 4.1.3(11), 4.1.6(1)(b), 4.22.6, 4.19.6.

c. The toilet centerline is 19 inches from the side wall.  Provide a toilet with a centerline that measures 18 inches from the near side wall.  Standards §§ 4.1.3(11), 4.1.6(1)(b), 4.22.4, 4.16.2, Fig. 28.

 

8.         Small, Unisex, Single-User Toilet Room (Rodwell House)

a. The toilet room lacks an accessible sign.  Provide a toilet room sign with raised and Braille characters.  The sign shall be mounted on the wall adjacent to the latch side of the door with the centerline of the sign at 60 inches above the finished floor and situated such that a person can approach within 3 inches of the sign without encountering an obstruction or standing within a door swing.  Standards §§ 4.1.2(7)(d), 4.1.6(1)(b), 4.30.1, 4.30.4, 4.30.5, 4.30.6.