ATTACHMENT J: Modifications to Altered Facilities

 

Please Note:  Paragraph 58 of the Settlement Agreement requires that within one (1) year of the effective date of this Agreement, the City of Milwaukee provide signage as necessary to comply with 28 C.F.R. § 35.163(b), after having surveyed all facilities that are the subject of this Agreement for the purpose of identifying those that have multiple entrances not all of which are accessible.

 

The chart below lists the facilities surveyed by the Department, the access issues identified during the survey, and the actions required to correct the access issues.  Required actions are listed using an alphanumeric code.  The key to the alphanumeric codes is provided in Attachment M to this Agreement. 

 

In order to ensure that the following spaces and elements in the City€™s facilities in which alterations occurred after January 26, 1992, are readily accessible to and usable by persons with disabilities, the City will take the actions referenced by the alphanumeric code and described in detail in Attachment M to this Settlement Agreement within the time period specified below, which time period will begin to run on the effective date of this Agreement.

 

Item #

 

Access Issue

 

Required Action

 

Completion Date

 

1.                   

 

City Hall, 200 E. Wells

 

 

 

 

 

1.1.             

 

Entrances (generally):

 

 

 

 

 

1.1.1.       

 

The building does not have directional signage posted at some of the inaccessible entrances and does not have the International Symbol of Accessibility posted at accessible entrances.

 

D10

 

12 months

 

1.2.             

 

Tunnel to Zeider Municipal Building: The top segment of the ramp closest to City Hall, with a 5.6% slope, is inaccessible because it lacks handrails on both sides of the segment.

 

R2

 

24 months

 

1.3.             

 

Basement men€™s toilet room with stalls (near Room B1):

 

 

 

 

 

1.3.1.       

 

The hand dryer protrudes into the walkway and is not detectable to blind persons using a cane.

 

AR7

 

12 months

 

1.3.2.       

 

The designated accessible toilet is inaccessible because the side grab bar is mounted with its farther end 48 inches from the rear wall.

 

TR17

 

30 months

 

1.4.             

 

Basement women€™s toilet room with stalls (near Room B1):

 

 

 

 

 

1.4.1.       

 

No accessible coat hook has been provided.

 

TR3

 

12 months

 

1.4.2.       

 

The designated accessible toilet is inaccessible because the side grab bar is mounted with its farther end 48 inches from the rear wall.

 

TR17

 

12 months

 

1.5.             

 

Basement drinking fountain near Room B1:

 

 

 

 

 

1.5.1.       

 

The drinking fountain is inaccessible because it has a spout that is 37¼ inches high.

 

DF3

 

30 months

 

1.5.2.       

 

Although a designated accessible drinking fountain is provided, there is no drinking fountain provided for people who have difficulty bending or stooping.

 

DF3

 

30 months

 

1.5.3.       

 

The drinking fountain protrudes into the walkway and is not detectable to blind persons using a cane.

 

AR7

 

12 months

 

1.6.             

 

1st floor women€™s toilet room with stalls:

 

 

 

 

 

1.6.1.       

 

No accessible mirror has been provided.

 

TR5

 

12 months

 

1.6.2.       

 

The baby changing station is inaccessible because it is mounted with the handle more than 54 inches high.

 

DW1

 

12 months

 

1.6.3.       

 

The baby changing station is inaccessible because it does not have adequate clear floor space in front of it.

 

AR10

 

12 months

 

1.6.4.       

 

The toilet seat cover dispenser is inaccessible because it is mounted 51 inches high behind the toilet.

 

CT3

 

12 months

 

1.6.5.       

 

The designated accessible toilet is inaccessible because the side grab bar is mounted with its farther end 50 inches from the rear wall.

 

TR17

 

12 months

 

1.7.             

 

1st floor men€™s toilet room with stalls:

 

 

 

 

 

1.7.1.       

 

The toilet room sign has no raised or Braille characters.

 

TR11

 

12 months

 

1.7.2.       

 

No accessible mirror has been provided.

 

TR5

 

12 months

 

1.8.             

 

1st floor City Treasurer€™s Office: The room number signage provided is inaccessible because it does not have raised and Braille characters.

 

D15

 

12 months

 

1.9.             

 

2nd floor interior route:

 

 

 

 

 

1.9.1.       

 

The hallway defibrillator protrudes into the walkway and is not detectable to blind persons using a cane.

 

AR7

 

12 months

 

1.9.2.       

 

The sprinkler valve protrudes into the walkway and is not detectable to blind persons using a cane.

 

AR7

 

12 months

 

1.10.         

 

2nd floor drinking fountain:

 

 

 

 

 

1.10.1.   

 

The drinking fountain is inaccessible because it has a spout that is 37½ inches high, it does not have adequate knee and toe clearance, and the controls require tight grasping and twisting to operate.

 

DF1

 

30 months

 

1.10.2.   

 

Although a designated accessible drinking fountain is provided, there is no drinking fountain provided for people who have difficulty bending or stooping.

 

DF3

 

30 months

 

1.10.3.   

 

The drinking fountain protrudes into the walkway and is not detectable to blind persons using a cane.

 

AR7

 

12 months

 

1.11.         

 

2nd floor men€™s toilet room with stalls:

 

 

 

 

 

1.11.1.   

 

The toilet room sign has no raised or Braille characters, and is mounted on the door. In addition, although this toilet room has accessible features, the signage directs people with disabilities to a different toilet room.

 

TR11

 

12 months

 

1.12.         

 

2nd floor women€™s toilet room with stalls:

 

 

 

 

 

1.12.1.   

 

The toilet room sign has no raised or Braille characters, and is mounted on the door. In addition, although this toilet room has accessible features, the signage directs people with disabilities to a different toilet room.

 

TR11

 

12 months

 

1.13.         

 

3rd floor interior route: The defibrillator protrudes into the walkway and is not detectable to blind persons using a cane.

 

AR7

 

12 months

 

1.14.         

 

3rd floor drinking fountain:

 

 

 

 

 

1.14.1.   

 

The drinking fountain is inaccessible because it has a spout that is 37 inches high, it does not have adequate knee and toe clearance, and the controls require tight grasping and twisting to operate.

 

DF1

 

30 months

 

1.14.2.   

 

Although a designated accessible drinking fountain is provided, there is no drinking fountain provided for people who have difficulty bending or stooping.

 

DF3

 

30 months

 

1.14.3.   

 

The drinking fountain protrudes into the walkway and is not detectable to blind persons using a cane.

 

AR7

 

12 months

 

1.15.         

 

3rd floor women€™s toilet room with stalls:

 

 

 

 

 

1.15.1.   

 

The toilet room sign has no raised or Braille characters and is mounted on the door. In addition, although this toilet room has accessible features, the signage directs people with disabilities to a different toilet room.

 

TR11

 

12 months

 

1.15.2.   

 

The toilet seat cover dispenser is inaccessible because it is mounted 56 inches high behind the toilet.

 

CT3

 

12 months

 

1.15.3.   

 

No accessible coat hook has been provided.

 

TR3

 

24 months

 

1.16.         

 

3rd floor men€™s toilet room with stalls:

 

 

 

 

 

1.16.1.   

 

The toilet room sign has no raised or Braille characters and is mounted on the door. In addition, although this toilet room has accessible features, the signage directs people with disabilities to a different toilet room.

 

TR11

 

12 months

 

1.16.2.   

 

The designated accessible toilet is inaccessible because the top of the seat is 19½ inches high.

 

TR9

 

30 months

 

1.17.         

 

3rd floor Common Council Hearing Room A: The room is inaccessible to people with hearing disabilities because there is no assistive listening system provided.  This room requires 3 receivers of which two are hearing-aid compatible.

 

AA4

 

30 months

 

1.18.         

 

3rd floor Common Council Hearing Room B: The room is inaccessible to people with hearing disabilities because there is no assistive listening system provided.  This room requires 4 receivers of which two are hearing-aid compatible.

 

AA4

 

30 months

 

1.19.         

 

Common Council Chamber:

 

 

 

 

 

1.19.1.   

 

The Common Council Chamber is inaccessible to people with hearing disabilities because there is no assistive listening system provided.

 

AA4

 

30 months

 

1.20.         

 

Common Council Chamber drinking fountain:

 

 

 

 

 

1.20.1.   

 

The drinking fountain is inaccessible because it has a spout that is 41¼ inches high, has inadequate knee and toe clearance, and has inadequate clear floor space in front of the fountain.

 

DF1

 

30 months

 

1.21.         

 

4th floor interior route: The hallway defibrillator protrudes into the walkway and is not detectable to blind persons using a cane.

 

AR7

 

12 months

 

1.22.         

 

4th floor women€™s toilet room with stalls:

 

 

 

 

 

1.22.1.   

 

The toilet room sign is not mounted with its tactile characters between 48 and 60 inches high.

 

TR11

 

12 months

 

1.22.2.   

 

The sanitary napkin dispenser is inaccessible because the controls require twisting of the wrist to operate.

 

CT2

 

24 months

 

1.22.3.   

 

The sanitary napkin dispenser protrudes into the walkway and is not detectable to blind persons using a cane.

 

AR7

 

12 months

 

1.22.4.   

 

The paper towel dispenser by the window protrudes into the walkway and is not detectable to blind persons using a cane.

 

AR7

 

12 months

 

1.22.5.   

 

 

The designated accessible toilet is inaccessible because the side grab bar is mounted with its farther end 51 inches from the rear wall.

 

TR17

 

24 months

 

1.23.         

 

4th floor men€™s toilet room with stalls:

 

 

 

 

 

1.23.1.   

 

The toilet room sign is not mounted with its tactile characters between 48 and 60 inches high.

 

TR11

 

12 months

 

1.23.2.   

 

No accessible mirror has been provided.

 

TR5

 

24 months

 

1.24.         

 

5th floor interior route: The defibrillator protrudes into the walkway and is not detectable to blind persons using a cane.

 

AR7

 

12 months

 

1.25.         

 

5th floor women€™s toilet room with stalls:

 

 

 

 

 

1.25.1.   

 

The toilet room sign is not mounted with its tactile characters between 48 and 60 inches high.

 

TR11

 

12 months

 

1.25.2.   

 

The sanitary napkin dispenser is inaccessible because the controls require twisting of the wrist to operate.

 

CT2

 

24 months

 

1.25.3.   

 

The sanitary napkin dispenser protrudes into the walkway and is not detectable to blind persons using a cane.

 

AR7

 

12 months

 

1.25.4.   

 

The designated accessible toilet is inaccessible because the flush control is on the closed side.

 

TR4

 

30 months

 

1.25.5.   

 

The toilet seat cover dispenser is inaccessible because it is mounted 55 inches high behind the toilet.

 

CT3

 

12 months

 

1.25.6.   

 

 

The designated accessible toilet is inaccessible because the side grab bar is mounted with its farther end 51 inches from the rear wall.

 

TR17

 

12 months

 

1.26.         

 

5th floor men€™s toilet room with stalls:

 

 

 

 

 

1.26.1.   

 

The toilet room sign is not mounted with its tactile characters between 48 and 60 inches high.

 

TR11

 

12 months

 

1.26.2.   

 

The toilet seat cover dispenser is inaccessible because it is mounted 57 inches high behind the toilet.

 

TR6

 

12 months

 

1.26.3.   

 

The designated accessible toilet is inaccessible because the side grab bar is obstructed by the toilet paper dispenser.

 

TR15

 

12 months

 

1.27.         

 

5th floor Election Commission office (Room 501): The counter is inaccessible because it is 42 inches high.

 

C1

 

30 months

 

1.28.         

 

6th floor interior route: The defibrillator protrudes into the walkway and is not detectable to blind persons using a cane.

 

AR7

 

12 months

 

1.29.         

 

6th floor drinking fountains: The drinking fountains protrude into the walkway and are not detectable to blind persons using a cane.

 

AR7

 

12 months

 

1.30.         

 

6th floor men€™s toilet room with stalls:

 

 

 

 

 

1.30.1.   

 

The toilet room sign is not mounted with its tactile characters between 48 and 60 inches high.

 

TR11

 

12 months

 

1.30.2.   

 

The toilet seat cover dispenser is inaccessible because it is mounted 59 inches high behind the toilet.

 

TR6

 

12 months

 

1.31.         

 

6th floor women€™s toilet room with stalls:

 

 

 

 

 

1.31.1.   

 

The toilet room sign is not mounted with its tactile characters between 48 and 60 inches high.

 

TR11

 

12 months

 

1.31.2.   

 

The toilet seat cover dispenser is inaccessible because it is mounted 59 inches high behind the toilet.

 

TR6

 

12 months

 

1.32.         

 

7th floor interior route: The defibrillator protrudes into the walkway and is not detectable to blind persons using a cane.

 

AR7

 

12 months

 

1.33.         

 

7th floor men€™s toilet room with stalls:

 

 

 

 

 

1.33.1.   

 

The toilet room sign is not mounted with its tactile characters between 48 and 60 inches high.

 

TR11

 

12 months

 

1.34.         

 

7th floor women€™s toilet room with stalls:

 

 

 

 

 

1.34.1.   

 

The toilet room sign is not mounted with its tactile characters between 48 and 60 inches high.

 

TR11

 

12 months

 

1.34.2.   

 

The toilet seat cover dispenser is inaccessible because it is mounted 55 inches high behind the toilet.

 

TR6

 

12 months

 

1.34.3.   

 

The designated accessible toilet is inaccessible because the flush control is on the closed side.

 

TR4

 

30 months

 

1.34.4.   

 

No accessible coat hook has been provided.

 

TR3

 

24 months

 

1.35.         

 

8th floor interior route (existing): The defibrillator protrudes into the walkway and is not detectable to blind persons using a cane.

 

AR7

 

30 months

 

1.36.         

 

8th floor drinking fountain (existing):

 

 

 

 

 

1.36.1.   

 

The drinking fountain is inaccessible because it has inadequate knee and toe clearance.

 

DF4

 

30 months

 

1.36.2.   

 

Although a designated accessible drinking fountain is provided, there is no drinking fountain provided for people who have difficulty bending or stooping.

 

DF3

 

30 months

 

1.36.3.   

 

The drinking fountain protrudes into the walkway and is not detectable to blind persons using a cane.

 

AR7

 

30 months

 

1.37.         

 

8th floor men and women€™s toilet rooms (existing): These toilet rooms are not accessible. There is no signage directing people with disabilities to the accessible toilet rooms.

 

TR10

 

30 months

 

2.                   

 

26th and Medford Playground, 2476 N. 26th St.

 

 

 

 

 

2.1.             

 

Exterior route:

 

 

 

 

 

2.1.1.       

 

The route where the sidewalk meets the playground surface is inaccessible because there is a gap of several inches between the concrete and the playground€™s firm surface.

 

AR1

 

30 months

 

2.1.2.       

 

The route to the swings is inaccessible because it is not firm, stable, and slip-resistant.

 

AR1

 

30 months

 

2.1.3.       

 

There are no firm, stable, and slip-resistant spaces alongside the benches to allow a transfer.

 

PG1

 

30 months

 

3.                   

 

45th and Keefe Playground, 3512 N. 45th St.

 

 

 

 

 

3.1.             

 

 

Exterior route: The route leading into the playground from the street is inaccessible because there are slopes of up to 9.6% and cross-slopes of up to 8.6% along the route.

 

AR1

 

30 months

 

4.                   

 

84th and Burbank Playground, 6671 N. 84th St.

 

 

 

 

 

4.1.             

 

Exterior route:

 

 

 

 

 

4.1.1.       

 

The route where the sidewalk meets the playground is inaccessible because there are changes in level of two inches between the concrete and where it meets the playground€™s firm surface.

 

AR1

 

30 months

 

4.1.2.       

 

The route where the sidewalk meets the swing surface is inaccessible because there are changes in level of two inches between the concrete and where it meets the swing area€™s firm surface.

 

AR1

 

30 months

 

5.                   

 

90th and Bender Playground, 8900 W. Bender St.

 

 

 

 

 

5.1.             

 

Curb ramp near 90th / Bender: The curb ramp is inaccessible because its flared sides have slopes of up to 17.3%.

 

AR4

 

30 months

 

5.2.             

 

Bleachers:

 

 

 

 

 

5.2.1.       

 

The route to the bleachers is inaccessible because it is not firm, stable, and slip-resistant.

 

AR1

 

30 months

 

5.2.2.       

 

The bleachers are inaccessible because no wheelchair seating areas are provided.

 

AA6

 

30 months

 

5.3.             

 

Swings: The route to the swings is inaccessible because it is not firm, stable, or slip-resistant.

 

AR1

 

30 months

 

6.                   

 

809 Broadway Building, 809 N. Broadway

 

 

 

 

 

6.1.             

 

Tunnel to 809 Broadway from Zeidler Municipal Building: No accessible handrails are provided.

 

R2

 

24 months

 

6.2.             

 

Rear exterior entrance leading to basement: The interior vestibule entry door is inaccessible because it requires 12 pounds of force to open.

 

D3

 

12 months

 

6.3.             

 

 

Basement men€™s and women€™s employees-only toilet rooms near rear exterior entrance (existing): There is no signage directing people with disabilities to the accessible toilet rooms.

 

TR10

 

24 months

 

6.4.             

 

Exterior Ramp to Broadway Street Entrance: The ramp is inaccessible because the handrails lack 12 inch extensions at the bottom of the ramp. 

 

R2

 

24 months

 

6.5.             

 

1st floor board room (room 111): The board room is inaccessible to people with hearing disabilities because there is no assistive listening system provided.

 

AA4

 

30 months

 

6.6.             

 

1st floor glass interior doors leading to Zoning Appeals / Development Center counters: The doors are inaccessible because they require 15 pounds of force to open.

 

D3

 

12 months

 

6.7.             

 

1st floor women€™s toilet room with stalls:

 

 

 

 

 

6.7.1.       

 

The entrance door is inaccessible because it requires more than 5 pounds of force to open.

 

D3

 

12 months

 

6.7.2.       

 

No accessible mirror has been provided.

 

TR5

 

24 months

 

6.7.3.       

 

The sanitary napkin dispenser is inaccessible because the controls require twisting of the wrist to operate.

 

CT2

 

24 months

 

6.7.4.       

 

The lavatory is inaccessible because the top of the rim or counter is 34½ inches high.

 

LS3

 

30 months

 

6.7.5.       

 

No accessible coat hook has been provided.

 

TR3

 

24 months

 

6.7.6.       

 

The designated accessible toilet is inaccessible because the side grab bar is 36 inches long and it is mounted with the farther end 45 inches from the rear wall.

 

TR17

 

12 months

 

6.8.             

 

1st floor men€™s toilet room with stalls:

 

 

 

 

 

6.8.1.       

 

The entrance door is inaccessible because it requires more than 5 pounds of force to open.

 

D3

 

12 months

 

6.8.2.       

 

No accessible mirror has been provided.                

 

TR5

 

24 months

 

6.8.3.       

 

The paper towel dispenser protrudes into the walkway and is not detectable to blind persons using a cane.

 

AR7

 

12 months

 

6.8.4.       

 

The urinal is inaccessible because the rim is 23 inches high.

 

TR8

 

30 months

 

6.8.5.       

 

No accessible coat hook has been provided.

 

TR3

 

24 months

 

6.8.6.       

 

 

The designated accessible toilet is inaccessible because the side grab bar is 36 inches long and it is mounted with the farther end 44½ inches from the rear wall.

 

TR17

 

12 months

 

6.9.             

 

1st floor drinking fountain near toilet rooms: Although a designated accessible drinking fountain is provided, there is no drinking fountain provided for people who have difficulty bending or stooping.

 

DF3

 

30 months

 

6.10.         

 

1st floor interior route near toilet rooms: The fire extinguisher sign near the toilet rooms protrudes into the walkway and is not detectable to blind persons using a cane.

 

AR7

 

12 months

 

6.11.         

 

2nd floor conference rooms 2 East and 2 West: The entry doors are inaccessible because knob hardware is used.

 

D2

 

24 months

 

6.12.         

 

2nd floor men€™s toilet room with stalls:

 

 

 

 

 

6.12.1.   

 

The toilet room sign is mounted on the wall on the hinge side of the door and does not have the international symbol of access.

 

TR11

 

12 months

 

6.12.2.   

 

The door is inaccessible because it requires 20 pounds of force to open.

 

D3

 

12 months

 

6.12.3.   

 

Although an audible alarm is provided in this facility, there is no visual alarm appliance in the toilet room.

 

AL1

 

30 months

 

6.12.4.   

 

No accessible mirror has been provided.

 

TR5

 

24 months

 

6.12.5.   

 

The towel dispenser protrudes into the walkway and is not detectable to blind persons using a cane.

 

AR7

 

12 months

 

6.12.6.   

 

The urinal is inaccessible because the rim is 24 inches high.

 

TR8

 

30 months

 

6.12.7.   

 

The designated accessible toilet stall is inaccessible because it is 48 inches wide.

 

TR23

 

30 months

 

6.12.8.   

 

The designated accessible toilet is inaccessible because the flush control is on the closed side.

 

TR4

 

30 months

 

6.12.9.   

 

The toilet paper dispenser in the designated accessible stall is inaccessible because it is mounted on the incorrect side wall.

 

TR6

 

24 months

 

6.12.10.                       

 

The designated accessible toilet is inaccessible because the side grab bar is 36 inches long and it is mounted with its farther end 45 inches from the rear wall.

 

TR17

 

12 months

 

6.12.11.                       

 

There is no rear grab bar provided at the designated accessible toilet.

 

TR13

 

24 months

 

6.13.         

 

2nd floor women€™s toilet room with stalls:

 

 

 

 

 

6.13.1.   

 

The toilet room sign is mounted on the hinge side of the door and does not have the international symbol of access.

 

TR11

 

12 months

 

6.13.2.   

 

The door is inaccessible because it requires 20 pounds of force to open.

 

D3

 

12 months

 

6.13.3.   

 

Although an audible alarm is provided in this facility, there is no visual alarm appliance in the toilet room.

 

AL1

 

30 months

 

6.13.4.   

 

No accessible mirror has been provided.

 

TR5

 

24 months

 

6.13.5.   

 

The sanitary napkin dispenser is inaccessible because the controls require twisting of the wrist to operate.

 

CT2

 

24 months

 

6.13.6.   

 

The designated accessible toilet stall is inaccessible because it is 47 inches wide.

 

TR23

 

30 months

 

6.13.7.   

 

The pull side of the toilet compartment door, which is accessed through a front approach, is inaccessible because it does not have 18 inches minimum of clear space on the latch side.

 

D5

 

30 months

 

6.13.8.   

 

No accessible coat hook has been provided.

 

TR3

 

24 months

 

6.13.9.   

 

The toilet paper dispenser in the designated accessible stall is inaccessible because it is mounted on the incorrect side wall.

 

TR6

 

12 months

 

6.13.10.                       

 

The designated accessible toilet is inaccessible because the side grab bar is 36 inches long and it is mounted with its farther end 45 inches from the rear wall.

 

TR17

 

12 months

 

6.13.11.                       

 

There is no rear grab bar provided at the designated accessible toilet.

 

TR13

 

24 months

 

6.14.         

 

2nd floor drinking fountain between toilet rooms:

 

 

 

 

 

6.14.1.   

 

The drinking fountain is inaccessible because it has a spout that is 37 inches high.

 

DF3

 

30 months

 

6.14.2.   

 

Although a designated accessible drinking fountain is provided, there is no drinking fountain provided for people who have difficulty bending or stooping.

 

DF3

 

30 months

 

6.14.3.   

 

The drinking fountain protrudes into the walkway and is not detectable to blind persons using a cane.

 

AR7

 

12 months

 

6.15.         

 

3rd floor interior route near elevator: The fire extinguisher sign near the elevator protrudes into the walkway and is not detectable to blind persons using a cane.

 

AR7

 

12 months

 

6.16.         

 

3rd floor conference rooms 3 East and 3 West: The entry doors are inaccessible because knob hardware is used.

 

D2

 

24 months

 

6.17.         

 

3rd floor men€™s toilet room with stalls:

 

 

 

 

 

6.17.1.   

 

The door is inaccessible because it requires 10 pounds of force to open.

 

D3

 

12 months

 

6.17.2.   

 

Although an audible alarm is provided in this facility, there is no visual alarm appliance in the toilet room.

 

AL1

 

30 months

 

6.17.3.   

 

No accessible mirror has been provided.

 

TR5

 

24 months

 

6.17.4.   

 

The towel dispenser protrudes into the walkway and is not detectable to blind persons using a cane.

 

AR7

 

12 months

 

6.17.5.   

 

The urinal is inaccessible because the rim is 24 inches high.

 

TR8

 

30 months

 

6.17.6.   

 

The designated accessible toilet stall is inaccessible because it is 48 inches wide.

 

TR23

 

30 months

 

6.17.7.   

 

No accessible coat hook has been provided.

 

TR3

 

24 months

 

6.17.8.   

 

The designated accessible toilet is inaccessible because the flush control is on the closed side.

 

TR4

 

30 months

 

6.17.9.   

 

The toilet paper dispenser in the designated accessible stall is inaccessible because it is mounted on the incorrect side wall.

 

TR6

 

12 months

 

6.17.10.                       

 

The designated accessible toilet is inaccessible because the side grab bar is 36 inches long and it is mounted with its farther end 46 inches from the rear wall.

 

TR17

 

12 months

 

6.17.11.                       

 

There is no rear grab bar provided at the designated accessible toilet.

 

TR13

 

24 months

 

6.18.         

 

3rd floor women€™s toilet room with stalls:

 

 

 

 

 

6.18.1.   

 

The toilet room sign is mounted on the door.

 

TR11

 

12 months

 

6.18.2.   

 

The door is inaccessible because it requires 14 pounds of force to open.

 

D3

 

12 months

 

6.18.3.   

 

Although an audible alarm is provided in this facility, there is no visual alarm appliance in the toilet room.

 

AL1

 

30 months

 

6.18.4.   

 

No accessible mirror has been provided.

 

TR5

 

24 months

 

6.18.5.   

 

The sanitary napkin dispenser is inaccessible because the controls require twisting of the wrist to operate.

 

CT2

 

24 months

 

6.18.6.   

 

The pull side of the toilet compartment door, which is accessed through a front approach, is inaccessible because it does not have 18 inches minimum of clear space on the latch side.

 

D5

 

30 months

 

6.18.7.   

 

The toilet seat cover dispenser is inaccessible because it is mounted 60½ inches high behind the toilet.

 

CT3

 

12 months

 

6.18.8.   

 

The designated accessible toilet stall is inaccessible because it is 46 inches wide and 60 inches deep.

 

TR23

 

30 months

 

6.18.9.   

 

No accessible coat hook has been provided.

 

TR3

 

24 months

 

6.18.10.                       

 

The toilet paper dispenser in the designated accessible stall is inaccessible because it is mounted on the incorrect side wall.

 

TR6

 

12 months

 

6.18.11.                       

 

The designated accessible toilet is inaccessible because the side grab bar is 36 inches long and it is mounted with its farther end 40 inches from the rear wall.

 

TR17

 

12 months

 

6.18.12.                       

 

There is no rear grab bar provided at the designated accessible toilet.

 

TR13

 

24 months

 

6.19.         

 

3rd floor drinking fountain between toilet rooms:

 

 

 

 

 

6.19.1.   

 

Although a designated accessible drinking fountain is provided, there is no drinking fountain provided for people who have difficulty bending or stooping.

 

DF3

 

30 months

 

6.19.2.   

 

The drinking fountain protrudes into the walkway and is not detectable to blind persons using a cane.

 

AR7

 

12 months

 

7.                   

 

Atkinson Library, 1960 W. Atkinson Av.

 

 

 

 

 

7.1.             

 

Parking: The parking lot is inaccessible because the access aisle is not of the required width for the entire length of the accompanying parking space.

 

P2

 

30 months

 

7.2.             

 

Exterior route from parking to the main entrance:  The route is inaccessible because there is a level change exceeding ½ inch where the access aisle meets the sidewalk.

 

AR1

 

30 months

 

7.3.             

 

Book return: The book return depository is inaccessible because the clear floor space is obstructed by the arc of the entrance door swing.

 

AR10

 

12 months

 

7.4.             

 

Women€™s single-user toilet room:

 

 

 

 

 

7.4.1.       

 

The toilet room sign has no raised or Braille characters.

 

TR11

 

12 months

 

7.4.2.       

 

The pull side of the door, which is accessed through a front approach, is inaccessible because it has less than 18 inches of clear space on the latch side.

 

D5

 

30 months

 

7.4.3.       

 

No accessible mirror has been provided.

 

TR5

 

24 months

 

7.4.4.       

 

The lavatory is inaccessible because the hot water and drain pipes are not insulated or otherwise configured to protect against contact.

 

LS2

 

24 months

 

7.4.5.       

 

The air hand dryer protrudes into the walkway and is not detectable to blind persons using a cane.

 

AR7

 

12 months

 

7.4.6.       

 

The toilet is inaccessible because the top of the seat is 19½ inches high.

 

TR9

 

30 months

 

7.4.7.       

 

The toilet is inaccessible because its centerline is 18¾ inches from the side wall.

 

TR7

 

30 months

 

7.4.8.       

 

 

The sanitary napkin dispenser is inaccessible because the controls require twisting of the wrist to operate.

 

CT2

 

24 months

 

7.5.             

 

Men€™s single-user toilet room:

 

 

 

 

 

7.5.1.       

 

The toilet room sign has no raised or Braille characters.

 

TR11

 

12 months

 

7.5.2.       

 

The pull side of the door, which is accessed through a front approach, is inaccessible because it has less than 12 inches of clear space on the latch side.

 

D5

 

30 months

 

7.5.3.       

 

No accessible mirror has been provided.

 

TR5

 

24 months

 

7.5.4.       

 

The lavatory is inaccessible because the hot water and drain pipes are not insulated or otherwise configured to protect against contact.

 

LS2

 

24 months

 

7.5.5.       

 

The lavatory is inaccessible because it has twist-type hardware.

 

LS4

 

30 months

 

7.5.6.       

 

The air hand dryer protrudes into the walkway and is not detectable to blind persons using a cane.

 

AR7

 

12 months

 

7.5.7.       

 

The toilet is inaccessible because the flush control is on the closed side.

 

TR4

 

30 months

 

7.5.8.       

 

The toilet is inaccessible because its centerline is 19½ inches from the side wall.

 

TR7

 

30 months

 

7.6.             

 

Drinking fountain near toilet rooms:

 

 

 

 

 

7.6.1.       

 

The wall-mounted drinking fountain is inaccessible because it provides only 26½ inches of clear knee height.

 

DF4

 

30 months

 

7.6.2.       

 

Although a designated accessible drinking fountain is provided, there is no drinking fountain provided for people who have difficulty bending or stooping.

 

DF3

 

30 months

 

8.                   

 

Butterfly Park, 3717 W. Meinecke Av.

 

 

 

 

 

8.1.             

 

Exterior routes:

 

 

 

 

 

8.1.1.       

 

The route from the sidewalk to the swings is inaccessible because there is a change in level where the sidewalk meets the swing play surface.

 

AR1

 

30 months

 

8.1.2.       

 

The route from the sidewalk to the playground is inaccessible because there is a change in level where the sidewalk meets the playground area surface.

 

AR1

 

30 months

 

9.                   

 

Capitol Library, 3969 N. 74th St.

 

 

 

 

 

9.1.             

 

Parking: The designated accessible parking is inaccessible because the access aisle slopes 2.7%.

 

P4

 

30 months

 

9.2.             

 

Exterior ramp between parking lot and entrance: The ramp is inaccessible because it has a cross-slope of up to 4.3%. 

 

R4

 

30 months

 

9.3.             

 

Exterior route between ramp and entrance: The route is inaccessible because there are cross-slopes of up to 4.1%.

 

AR1

 

30 months

 

9.4.             

 

Route from front entrance into library: The route is inaccessible because it slopes 5.3% with no ramp features.

 

AR1

 

30 months

 

9.5.             

 

Women€™s single-user toilet room:

 

 

 

 

 

9.5.1.       

 

The toilet room sign is mounted on the door.

 

TR11

 

12 months

 

9.5.2.       

 

The door is inaccessible because it requires 10 pounds of force to open.

 

D3

 

12 months

 

9.5.3.       

 

No accessible coat hook has been provided.

 

TR3

 

24 months

 

9.5.4.       

 

The lavatory is inaccessible because the hot water and drain pipes are not insulated or otherwise configured to protect against contact.

 

LS2

 

24 months

 

9.5.5.       

 

The toilet is inaccessible because the top of the seat is 16 inches high.

 

TR9

 

30 months

 

9.5.6.       

 

 

The toilet is inaccessible because the rear grab bar is mounted with its closer end 12 inches from the side wall.

 

TR14

 

24 months

 

9.6.             

 

Men€™s single-user toilet room:

 

 

 

 

 

9.6.1.       

 

The toilet room sign is mounted on the door.

 

TR11

 

12 months

 

9.6.2.       

 

The door is inaccessible because it requires 7 pounds of force to open.

 

D3

 

12 months

 

9.6.3.       

 

No accessible mirror has been provided.

 

TR5

 

24 months

 

9.6.4.       

 

The lavatory is inaccessible because the hot water and drain pipes are not insulated or otherwise configured to protect against contact.

 

LS2

 

24 months

 

9.6.5.       

 

The toilet is inaccessible because the top of the seat is 15 inches high.

 

TR9

 

30 months

 

9.6.6.       

 

The toilet is inaccessible because the flush control is on the closed side.

 

TR4

 

30 months

 

9.6.7.       

 

 

The toilet is inaccessible because the rear grab bar is mounted with its closer end 8 inches from the side wall.

 

TR14

 

24 months

 

10.               

 

Cass Playground, 1620 N. Cass St.

 

 

 

 

 

10.1.         

 

Exterior route: The route to the tennis courts is inaccessible because it is not firm, stable, or slip-resistant.

 

AR1

 

30 months

 

10.2.         

 

Picnic tables: The picnic tables are inaccessible because none provide the required knee space.

 

DW1

 

30 months

 

11.               

 

Central Library, 814 W. Wisconsin Av.

 

 

 

 

 

11.1.         

 

Exterior entrances: Although the building has directional signage posted at inaccessible entrances, it does not have the International Symbol of Accessibility posted at the accessible entrance.

 

D10

 

12 months

 

11.2.         

 

Interior ramp near 8th Street entrance: The ramp is inaccessible because the handrails do not have 12 inch extensions at the bottom of the ramp.

 

R2

 

24 months

 

11.3.         

 

Ground level drinking fountain:

 

 

 

 

 

11.3.1.   

 

The drinking fountain is inaccessible because it provides only 24¾ inches of clear knee height.

 

DF4

 

30 months

 

11.3.2.   

 

Although two lower fountains are provided, there is no drinking fountain provided for people who have difficulty bending or stooping.

 

DF3

 

30 months

 

11.4.         

 

1st floor meeting room: The meeting room is inaccessible to people with hearing disabilities because there is no assistive listening system provided.

 

AA4

 

30 months

 

11.5.         

 

1st floor men€™s toilet room with stalls near main entrance:

 

 

 

 

 

11.5.1.   

 

No accessible mirror has been provided.

 

TR5

 

24 months

 

11.5.2.   

 

The air dryer protrudes into the walkway and is not detectable to blind persons using a cane.

 

AR7

 

12 months

 

11.5.3.   

 

The lavatory is inaccessible because the hot water and drain pipes are not insulated or otherwise configured to protect against contact.

 

LS2

 

24 months

 

11.5.4.   

 

The pull side of the door, which is accessed through a front approach, is inaccessible because it does not have at least 12 inches of clear space on the latch side.

 

D5

 

30 months

 

11.5.5.   

 

The designated accessible toilet is inaccessible because the top of the seat is 19¼ inches high.

 

TR9

 

30 months

 

11.5.6.   

 

The designated accessible toilet is inaccessible because the side grab bar is obstructed by the toilet paper dispenser.

 

TR15

 

12 months

 

11.5.7.   

 

The designated accessible toilet is inaccessible because the side grab bar is mounted with its farther end 45 inches from the rear wall.

 

TR17

 

12 months

 

11.6.         

 

1st floor women€™s toilet room with stalls near main entrance:

 

 

 

 

 

11.6.1.   

 

No accessible mirror has been provided.

 

TR5

 

24 months

 

11.6.2.   

 

The air dryer protrudes into the walkway and is not detectable to blind persons using a cane.

 

AR7

 

12 months

 

11.6.3.   

 

The sanitary napkin dispenser protrudes into the walkway and is not detectable to blind persons using a cane.

 

AR7

 

12 months

 

11.6.4.   

 

The sanitary napkin dispenser is inaccessible because the controls require twisting of the wrist to operate.

 

CT2

 

24 months

 

11.6.5.   

 

No accessible coat hook has been provided.

 

TR3

 

24 months

 

11.6.6.   

 

The pull side of the door, which is accessed through a front approach, is inaccessible because it does not have at least 12 inches of clear space on the latch side.

 

D5

 

30 months

 

11.6.7.   

 

The designated accessible toilet is inaccessible because the side grab bar is mounted with its farther end 44 inches from the rear wall.

 

TR17

 

12 months

 

11.7.         

 

1st floor drinking fountain between toilets near main entrance:

 

 

 

 

 

11.7.1.   

 

The wall-mounted drinking fountain is inaccessible because it provides only 26½ inches of clear knee height.

 

DF4

 

30 months

 

11.7.2.   

 

The higher drinking fountain protrudes into the walkway and is not detectable to blind persons using a cane.

 

AR7

 

12 months

 

11.8.         

 

1st floor children / caretakers€™ men€™s toilet room with stalls near children€™s area:

 

 

 

 

 

11.8.1.   

 

The toilet room sign is not accessible.

 

TR11

 

12 months

 

11.8.2.   

 

The air dryer protrudes into the walkway and is not detectable to blind persons using a cane.

 

AR7

 

12 months

 

11.9.         

 

1st floor children / caretakers€™ women€™s toilet room with stalls near children€™s area:

 

 

 

 

 

11.9.1.   

 

The toilet room sign is not accessible.

 

TR11

 

12 months

 

11.9.2.   

 

The air dryer protrudes into the walkway and is not detectable to blind persons using a cane.

 

AR7

 

12 months

 

11.10.     

 

2nd floor women€™s toilet room with stalls in the Arts Wing:

 

 

 

 

 

11.10.1.                       

 

No accessible mirror has been provided.

 

TR5

 

24 months

 

11.10.2.                       

 

The air dryer protrudes into the walkway and is not detectable to blind persons using a cane.

 

AR7

 

12 months

 

11.10.3.                       

 

The sanitary napkin dispenser is inaccessible because the controls require twisting of the wrist to operate.

 

CT2

 

24 months

 

11.11.     

 

2nd floor men€™s toilet room with stalls in the Arts Wing:

 

 

 

 

 

11.11.1.                       

 

No accessible mirror has been provided.

 

TR5

 

24 months

 

11.11.2.                       

 

The air dryer protrudes into the walkway and is not detectable to blind persons using a cane.

 

AR7

 

12 months

 

12.               

 

Environmental Education and Recycling Center, 1313 W. Mt. Vernon Av.

 

 

 

 

 

12.1.         

 

Parking lot: The unmarked parking lot, with a total of approximately 16 parking spaces, is inaccessible because it has no spaces designated as accessible.  This lot requires 1 van accessible space.

 

P1

 

30 months

 

12.2.         

 

Women€™s toilet room with stalls:

 

 

 

 

 

12.2.1.   

 

The toilet room sign has no raised or Braille characters.

 

TR11

 

12 months

 

12.2.2.   

 

The door is inaccessible because knob hardware is used.

 

D2

 

24 months

 

12.2.3.   

 

Although an audible alarm is provided in this facility, there is no visual alarm appliance in the toilet room.

 

AL1

 

30 months

 

12.2.4.   

 

The route to the toilet room is inaccessible because the vestibule (with change in direction) between the two entrance doors does not provide sufficient depth.

 

AR1

 

30 months

 

12.2.5.   

 

The lavatory is inaccessible because the hot water and drain pipes are not insulated or otherwise configured to protect against contact.

 

LS2

 

24 months

 

12.2.6.   

 

No accessible coat hook has been provided.

 

TR3

 

24 months

 

12.2.7.   

 

The designated accessible stall is incorrectly configured as an ambulatory or alternate stall, and there is no standard accessible stall provided.

 

TR2

 

30 months

 

12.3.         

 

Men€™s toilet room with stalls:

 

 

 

 

 

12.3.1.   

 

The toilet room sign is mounted on the door and has no raised or Braille characters.

 

TR11

 

12 months

 

12.3.2.   

 

The door is inaccessible because knob hardware is used.                              

 

D2

 

24 months

 

12.3.3.   

 

Although an audible alarm is provided in this facility, there is no visual alarm appliance in the toilet room.

 

AL1

 

30 months

 

12.3.4.   

 

The paper towel dispenser is inaccessible because it is mounted with the controls 60 inches high.

 

CT4

 

12 months

 

12.3.5.   

 

No accessible coat hook has been provided.

 

TR3

 

24 months

 

12.3.6.   

 

The pull side of the door, which is accessed through a front approach, is inaccessible because it does not have at least 18 inches of clear space on the latch side.

 

D5

 

30 months

 

12.3.7.   

 

The designated accessible stall is incorrectly configured as an ambulatory or alternate stall, and there is no standard accessible stall provided.

 

TR2

 

30 months

 

12.3.8.   

 

The bench is inaccessible because it is less than 24 inches wide and is not secured to the wall or provides back support.

 

LR2

 

24 months

 

12.4.         

 

Observatory: The lift to the Observatory is inaccessible because it has not been maintained in working order.

 

M1

 

30 months

 

13.               

 

Forest Home Library, 1432 W. Forest Home Av.

 

 

 

 

 

13.1.         

 

Women€™s single-user toilet room: The pull side of the door, which is accessed through a front approach, is inaccessible because a drinking fountain obstructs the door€™s required maneuvering clearance.

 

D5

 

30 months

 

14.               

 

Jewell Play Field and Field House, 1801/1810 W. Wood Av.

 

 

 

 

 

14.1.         

 

Men€™s toilet room:

 

 

 

 

 

14.1.1.   

 

This toilet room was locked at the time of the survey. Ensure that this toilet room is fully accessible.

 

TR1

 

30 months

 

14.1.2.   

 

The entry door is inaccessible because there is a 2 inch high threshold.

 

D12

 

30 months

 

14.2.         

 

Women€™s toilet room:

 

 

 

 

 

14.2.1.   

 

This toilet room was locked at the time of the survey. Ensure that this toilet room is fully accessible.

 

TR1

 

30 months

 

14.2.2.   

 

The toilet room is inaccessible because there is a 7 inch high step at the entry door.

 

D12

 

30 months

 

14.3.         

 

Exterior route:

 

 

 

 

 

14.3.1.   

 

The route to the swings is inaccessible because there is a 3 inch change of level where the sidewalk meets the play surface.

 

AR1

 

30 months

 

14.3.2.   

 

The curb ramp near the ballfield bleachers is inaccessible because it has a slope of 14½%.

 

AR4

 

30 months

 

14.4.         

 

Bleachers: The bleachers are inaccessible because there are no wheelchair spaces provided.

 

AA6

 

30 months

 

14.5.         

 

Benches: There are no firm, stable, and slip-resistant spaces alongside the benches to allow a transfer.

 

EB1

 

30 months

 

15.               

 

Keenan Health Center, 3200 N. 36th St.

 

 

 

 

 

15.1.         

 

Parking lot: The parking lot, with a total of 16 parking spaces of which one is designated as a standard accessible parking space, is inaccessible because it lacks van-accessible signage, the parking space and accompanying access aisle are not level, and the parking space is not on the shortest accessible route to the designated accessible entrance.  This lot requires 1 van accessible space.

 

P1

 

30 months

 

15.2.         

 

 

Exterior route: The route from the parking lot to the designated accessible entrance is inaccessible because the surface is not firm, stable, and slip-resistant.

 

AR1

 

30 months

 

15.3.         

 

Exterior designated accessible entrance:

 

 

 

 

 

15.3.1.   

 

The building does not have the International Symbol of Accessibility posted at accessible entrances.

 

D10

 

24 months

 

15.3.2.   

 

The designated accessible exterior door is inaccessible because there is a slope of 6.8% within the door€™s required maneuvering clearance.

 

D7

 

30 months

 

15.3.3.   

 

The designated accessible entrance door is inaccessible because knob hardware is used.

 

D2

 

24 months

 

15.3.4.   

 

The pull side of the door, which is accessed through a front approach, is inaccessible because it has only 15 inches of clear space on the latch side.

 

D5

 

30 months

 

15.4.         

 

Elevator serving the designated accessible entrance:

 

 

 

 

 

15.4.1.   

 

The elevator is inaccessible because the hall call buttons do not have visual signals on the buttons to indicate when the call is registered and answered.

 

E3

 

30 months

 

15.4.2.   

 

The elevator is inaccessible because the doors do not stay fully open a minimum of 3 seconds.

 

E6

 

30 months

 

15.4.3.   

 

The elevator is inaccessible because the emergency system requires voice communication to operate.

 

E7

 

30 months

 

15.5.         

 

Basement interior route: The route from the entrance to the Tuberculosis Clinic is inaccessible because it slopes up to 6% with no ramp features.

 

AR1

 

30 months

 

15.6.         

 

Basement - Tuberculosis Clinic:

 

 

 

 

 

15.6.1.   

 

The clinic entrance door along the carpeted route is inaccessible because it has an opening width of 27 inches.

 

D14

 

30 months

 

15.6.2.   

 

The clinic entrance door along the carpeted route is inaccessible because it requires 10 pounds of force to open.

 

D3

 

24 months

 

15.7.         

 

Basement unisex single-user toilet room:

 

 

 

 

 

15.7.1.   

 

The toilet room sign is mounted on the door and has no raised or Braille characters.

 

TR11

 

24 months

 

15.7.2.   

 

No accessible coat hook has been provided.

 

TR3

 

24 months

 

15.7.3.   

 

The soap dispenser is inaccessible because it is mounted with the controls 50 inches high, and requires a forward reach.

 

CT4

 

24 months

 

15.7.4.   

 

The toilet is inaccessible because the top of the seat is 15½ inches high.

 

TR9

 

30 months

 

15.7.5.   

 

The toilet paper dispenser is inaccessible because it is mounted on the rear wall.

 

TR6

 

24 months

 

15.7.6.   

 

The toilet is inaccessible because the flush control is on the closed side.

 

TR4

 

30 months

 

15.7.7.   

 

The toilet is inaccessible because there are no grab bars provided.

 

TR18

 

24 months

 

15.8.         

 

Doors throughout facility: Numerous interior doors are inaccessible because knob hardware is used.

 

D2

 

30 months

 

15.9.         

 

1st floor men€™s toilet room with stalls near the waiting room: The toilet room contains a number of inaccessible elements and is not accessible to people with disabilities.

 

TR1

 

30 months

 

15.10.     

 

1st floor women€™s toilet room with stalls near the waiting room: The toilet room contains a number of inaccessible elements and is not accessible to people with disabilities.

 

TR1

 

30 months

 

15.11.     

 

1st floor WIC waiting room: The sign-in counter is inaccessible because it is 42½ inches high.

 

C1

 

24 months

 

15.12.     

 

1st floor exam room 118:

 

 

 

 

 

15.12.1.                       

 

The entry doors are inaccessible because they have opening widths of 28½ inches each.

 

D14

 

30 months

 

15.12.2.                       

 

The entry doors are inaccessible because the vestibule is not sufficiently deep.

 

D4

 

30 months

 

15.12.3.                       

 

The pull side of the door, which is accessed through a front approach, is inaccessible because it has less than 18 inches of clear space on the latch side.

 

D5

 

30 months

 

15.12.4.                       

 

The room number sign is inaccessible because it does not have raised and Braille characters.

 

D15

 

30 months

 

15.13.     

 

1st floor drinking fountain near Station 4:

 

 

 

 

 

15.13.1.                       

 

The drinking fountain is inaccessible because the flow of water is not within 3 inches of the front of the fountain.

 

DF5

 

30 months

 

15.13.2.                       

 

The wall-mounted drinking fountain is inaccessible because it provides only 14 inches of clear knee depth.

 

DF4

 

30 months

 

15.13.3.                       

 

Although a designated accessible drinking fountain is provided, there is no drinking fountain provided for people who have difficulty bending or stooping.

 

DF3

 

30 months

 

15.14.     

 

2nd floor interior route: A fire extinguisher protrudes into the walkway near the STD clinic and is not detectable to blind persons using a cane.

 

AR7

 

30 months

 

15.15.     

 

3rd floor men€™s toilet room with stalls: The toilet room contains a number of inaccessible elements and is not accessible to people with disabilities.

 

TR1

 

30 months

 

15.16.     

 

3rd floor women€™s toilet room with stalls: The toilet room contains a number of inaccessible elements and is not accessible to people with disabilities.

 

TR1

 

30 months

 

16.               

 

Long Island Play Field, 5320 N. Long Island Dr.

 

 

 

 

 

16.1.         

 

Exterior route:

 

 

 

 

 

16.1.1.   

 

The route from the street to the sidewalk leading to the park is inaccessible because no curb ramp is provided.                                 

 

AR4

 

30 months

 

16.1.2.   

 

There are no firm, stable, and slip-resistant spaces alongside the benches to allow a transfer.

 

EB1

 

30 months

 

17.               

 

Marcus DeBack Play Field, 2461 N. 55th St.

 

 

 

 

 

17.1.         

 

Exterior route: The route to the swings is inaccessible because the surface is not firm, stable, and slip-resistant.

 

AR1

 

30 months

 

18.               

 

Martin Luther King Library, 310 W. Locust St.

 

 

 

 

 

18.1.         

 

Parking lot:

 

 

 

 

 

18.1.1.   

 

The designated van-accessible parking is inaccessible because the access aisle is 67 inches wide.

 

P6

 

30 months

 

18.1.2.   

 

The designated accessible parking is inaccessible because the access aisle slopes 2.6%.

 

P4

 

30 months

 

18.2.         

 

Exterior route: The route from the parking to the entrance is inaccessible because the curb ramp has a slope of 9.8%, and the flared sides have slopes of up to 27.9%.

 

AR4

 

30 months

 

18.3.         

 

Meeting room: The row of coat hooks is too high.

 

S1

 

12 months

 

18.4.         

 

Drinking fountains near meeting room: The higher drinking fountain protrudes into the walkway and is not detectable to blind persons using a cane.

 

AR7

 

12 months

 

18.5.         

 

Men€™s single-user toilet room:

 

 

 

 

 

18.5.1.   

 

The toilet room sign has no raised or Braille characters.

 

TR11

 

12 months

 

18.5.2.   

 

The door is inaccessible because it requires 7 pounds of force to open.

 

D3

 

12 months

 

18.5.3.   

 

No accessible coat hook has been provided.

 

TR3

 

24 months

 

18.5.4.   

 

No accessible mirror has been provided.

 

TR5

 

24 months

 

18.5.5.   

 

The baby changing station is inaccessible because it is mounted with the handle 57 inches high.

 

DW1

 

12 months

 

18.5.6.   

 

The toilet is inaccessible because its centerline is 19 inches from the side wall.

 

TR7

 

30 months

 

18.5.7.   

 

The toilet is inaccessible because the rear grab bar is 30 inches long.

 

TR14

 

24 months

 

18.6.         

 

Women€™s single-user toilet room:

 

 

 

 

 

18.6.1.   

 

The toilet room sign is mounted on the door and has no raised or Braille characters.

 

TR11

 

12 months

 

18.6.2.   

 

The door is inaccessible because it requires 8 pounds of force to open.

 

D3

 

12 months

 

18.6.3.   

 

No accessible coat hook has been provided.

 

TR3

 

24 months

 

18.6.4.   

 

The sanitary napkin dispenser is inaccessible because the controls require tight grasping to operate.

 

CT2

 

24 months

 

18.6.5.   

 

The sanitary napkin dispenser is inaccessible because the coin slot is higher than 48 inches high.

 

CT4

 

12 months

 

18.6.6.   

 

The baby changing station is inaccessible because it is mounted with the handle 57 inches high.

 

DW1

 

12 months

 

18.6.7.   

 

The toilet is inaccessible because the rear grab bar is 30 inches long.

 

TR14

 

24 months

 

19.               

 

Parking Structure at 1000 N. Water St.

 

 

 

 

 

19.1.         

 

The parking lot, with a total of 1542 parking spaces, is inaccessible because it only has 22 spaces designated as accessible. The 2nd through 8th levels each have 3 to 4 designated accessible parking spaces, but they all are not level and have signage that is mounted too low. No van-accessible parking spaces are provided.

 

P1

 

30 months

 

19.2.         

 

The elevator is inaccessible because the emergency system requires voice communication to operate.

 

E7

 

30 months

 

20.               

 

Police Administration Building, 749 W. State St.

 

 

 

 

 

20.1.         

 

Interior doors: Interior doors throughout the entire facility are inaccessible because knob hardware is used.

 

D2

 

30 months

 

20.2.         

 

Toilet rooms on each floor (except 2nd floor): The toilet rooms on each floor (except for the 2nd floor) contain a number of inaccessible elements and are not accessible to people with disabilities.

 

TR1

 

30 months

 

20.3.         

 

6th floor Sensitive Crimes Division (room 601): The counter is inaccessible because it is 42 inches high.

 

C1

 

30 months

 

20.4.         

 

Jail cells: There is no accessible cell provided.

 

PJ1

 

30 months

 

20.5.         

 

3rd floor Identification Division (room 305):

 

 

 

 

 

20.5.1.   

 

The counter is inaccessible because it is 40 inches high.

 

C1

 

30 months

 

20.5.2.   

 

The lavatory is inaccessible because the top of the rim or counter is 36 inches high, and it has no knee space underneath.

 

LS3

 

30 months

 

20.5.3.   

 

The paper towel dispenser is inaccessible because it is mounted with the controls 55 inches high over the lavatory.

 

CT4

 

24 months

 

20.5.4.   

 

 

The soap dispenser is inaccessible because it is mounted with the controls 48 inches high over the lavatory.

 

CT4

 

24 months

 

20.6.         

 

3rd floor drinking fountain next to sink: Although a designated accessible drinking fountain is provided, there is no drinking fountain provided for people who have difficulty bending or stooping.

 

DF3

 

30 months

 

20.7.         

 

2nd floor Parking Citations (room 204-J): The counter is inaccessible because it is 42 inches high.

 

C1

 

30 months

 

20.8.         

 

2nd floor First District room: The counter is inaccessible because it is 40½ inches high.

 

C1

 

30 months

 

20.9.         

 

2nd floor City Attorney€™s Office (room 205): The counter is inaccessible because it is 43 inches high.

 

C1

 

30 months

 

20.10.     

 

2nd floor Justice 2000 Office (room 204K): The counter is inaccessible because it is 40 inches high.

 

C1

 

30 months

 

20.11.     

 

2nd floor men€™s toilet room:

 

 

 

 

 

20.11.1.                       

 

The toilet room sign has no raised or Braille characters.

 

TR11

 

24 months

 

20.11.2.                       

 

The toilet seat cover dispenser is inaccessible because it is mounted 48 inches high behind the toilet.

 

CT3

 

24 months

 

20.11.3.                       

 

The soap dispenser is inaccessible because it is mounted with the controls 56 inches high.

 

CT4

 

24 months

 

20.11.4.                       

 

The paper towel dispenser is inaccessible because it is mounted with the controls 63 inches high.

 

CT4

 

24 months

 

20.11.5.                       

 

The lavatory is inaccessible because the hot water and drain pipes are not insulated or otherwise configured to protect against contact.

 

LS2

 

30 months

 

20.11.6.                       

 

The lavatory is inaccessible because it has twist-type hardware.

 

LS4

 

30 months

 

20.11.7.                       

 

The designated accessible stall is incorrectly configured as an ambulatory or alternate stall, and there is no standard accessible stall provided.

 

TR2

 

30 months

 

20.12.     

 

2nd floor women€™s toilet room:

 

 

 

 

 

20.12.1.                       

 

The toilet room sign has no raised or Braille characters.

 

TR11

 

24 months

 

20.12.2.                       

 

The toilet seat cover dispenser is inaccessible because it is mounted 48 inches high behind the toilet.

 

CT3

 

24 months

 

20.12.3.                       

 

The soap dispenser is inaccessible because it is mounted with the controls 44½ inches high over the lavatory.

 

CT3

 

24 months

 

20.12.4.                       

 

The paper towel dispenser is inaccessible because it is mounted with the controls 63 inches high.

 

CT4

 

24 months

 

20.12.5.                       

 

The lavatory is inaccessible because the hot water and drain pipes are not insulated or otherwise configured to protect against contact.

 

LS2

 

30 months

 

20.12.6.                       

 

The lavatory is inaccessible because it has twist-type hardware.

 

LS4

 

24 months

 

20.12.7.                       

 

No accessible coat hook has been provided.

 

TR3

 

24 months

 

20.12.8.                       

 

The designated accessible stall is incorrectly configured as an ambulatory or alternate stall, and there is no standard accessible stall provided.

 

TR2

 

30 months

 

20.13.     

 

1st floor police reception counter: The counter is inaccessible because it is 40 inches high.

 

C1

 

30 months

 

20.14.     

 

Branch 3 municipal courtroom:

 

 

 

 

 

20.14.1.                       

 

The witness stand is inaccessible because it can be accessed only by steps.

 

AA8

 

30 months

 

20.14.2.                       

 

The courtroom is inaccessible to people with hearing disabilities because there is no assistive listening system provided.

 

AA4

 

30 months

 

20.14.3.                       

 

The courtroom is inaccessible because no wheelchair seating areas are provided.

 

AA6

 

30 months

 

20.15.     

 

Elevator to street:

 

 

 

 

 

20.15.1.                       

 

The elevator is inaccessible because the hall call buttons do not have visual signals that indicate when a call is registered or answered.

 

E3

 

30 months

 

20.15.2.                       

 

The elevator is inaccessible because the time from notification that a car is answering a call until the doors of that car start to close is less than 5 seconds.

 

E6

 

30 months

 

20.15.3.                       

 

The elevator is inaccessible because the emergency system requires tight grasping or pinching to access.

 

E7

 

30 months

 

21.               

 

Police Safety Academy, 6680 N. Teutonia Av.

 

 

 

 

 

21.1.         

 

Parking lot: The parking lot, with a total of 122 parking spaces, is inaccessible because the 5 designated accessible parking spaces lack access aisles.  This lot requires 1 van accessible space and 4 standard accessible spaces.

 

P1

 

30 months

 

21.2.         

 

Exterior route: The route from the parking lot€™s curb ramp to the accessible rear entrance is inaccessible because there is a change in level measuring ¾ inches between the curb ramp and the sidewalk in front of the rear entrance.

 

AR1

 

30 months

 

21.3.         

 

Designated accessible entrance, vestibule: The designated accessible entrance is inaccessible because the vestibule is not sufficiently deep.

 

D4

 

30 months

 

21.4.         

 

Room signage throughout building: The signage provided is inaccessible because it does not have raised and Braille characters.

 

D15

 

24 months

 

21.5.         

 

Chapel Classroom 109: The pull side of the door, which is accessed through a front approach, is inaccessible because it has less than 18 inches of clear space on the latch side.

 

D5

 

30 months

 

21.6.         

 

Room 117:

 

 

 

 

 

21.6.1.   

 

The door is inaccessible because knob hardware is used.

 

D2

 

24 months

 

21.6.2.   

 

The counter is inaccessible because it is 43 inches high.

 

C1

 

30 months

 

21.7.         

 

Drinking fountain by Community Services / Safety (room 151):

 

 

 

 

 

21.7.1.   

 

The drinking fountain is inaccessible because the spout height measures 40 inches above the floor.

 

DF3

 

30 months

 

21.7.2.   

 

The drinking fountain is inaccessible because the controls require more than 5 pounds of pressure to operate.

 

DF2

 

30 months

 

21.7.3.   

 

The drinking fountain is inaccessible because it has insufficient toe and knee clearances.

 

DF4

 

30 months

 

21.7.4.   

 

The drinking fountain is inaccessible because there is not at least 30 inches maneuvering width centered on the fountain.

 

DF1

 

30 months

 

21.8.         

 

Drinking fountain by Printing and Stores (room 166):

 

 

 

 

 

21.8.1.   

 

The drinking fountain is inaccessible because the spout height measure 40 inches above the floor.

 

DF3

 

30 months

 

21.8.2.   

 

The drinking fountain is inaccessible because the controls require more than 5 pounds of pressure to operate.

 

DF2

 

30 months

 

21.8.3.   

 

The drinking fountain is inaccessible because it has insufficient toe and knee clearances.

 

DF4

 

30 months

 

21.8.4.   

 

The drinking fountain is inaccessible because there is not at least 30 inches maneuvering width centered on the fountain.

 

DF1

 

30 months

 

21.9.         

 

Drinking fountain by men€™s toilet room (room 182):

 

 

 

 

 

21.9.1.   

 

The drinking fountain is inaccessible because the spout height measures 40 inches above the floor.

 

DF3

 

30 months

 

21.9.2.   

 

The drinking fountain is inaccessible because the controls require more than 5 pounds of pressure to operate.

 

DF2

 

30 months

 

21.9.3.   

 

The drinking fountain is inaccessible because it has insufficient toe and knee clearances.

 

DF4

 

30 months

 

21.9.4.   

 

The drinking fountain is inaccessible because there is not at least 30 inches maneuvering width centered on the fountain.

 

DF1

 

30 months

 

21.10.     

 

Drinking fountain by Administrative (room 117):

 

 

 

 

 

21.10.1.                       

 

The drinking fountain is inaccessible because the spout height measures 40 inches above the floor.

 

DF3

 

30 months

 

21.10.2.                       

 

The drinking fountain is inaccessible because the controls require more than 5 pounds of pressure to operate.

 

DF2

 

30 months

 

21.10.3.                       

 

The drinking fountain is inaccessible because it has insufficient toe and knee clearances.

 

DF4

 

30 months

 

21.10.4.                       

 

The drinking fountain is inaccessible because there is not at least 30 inches maneuvering width centered on the fountain.

 

DF1

 

30 months

 

21.11.     

 

Theater (Room 142):

 

 

 

 

 

21.11.1.                       

 

The pull side of the entrance door, which is accessed through a front approach, is inaccessible because it has less than 18 inches of clear space on the latch side.

 

D5

 

30 months

 

21.11.2.                       

 

The door is inaccessible because knob hardware is used.

 

D2

 

30 months

 

21.12.     

 

Safety (Room 151):

 

 

 

 

 

21.12.1.                       

 

The pull side of the entrance door, which is accessed through a front approach, is inaccessible because it has less than 18 inches of clear space on the latch side.

 

D5

 

30 months

 

21.12.2.                       

 

The door is inaccessible because knob hardware is used.

 

D2

 

30 months

 

21.13.     

 

Women€™s toilet room with stalls (sometimes used as men€™s toilet room):

 

 

 

 

 

21.13.1.                       

 

The toilet room sign does not have raised or Braille characters.

 

TR11

 

24 months

 

21.13.2.                       

 

The door is inaccessible because it has an opening width of 30 inches.

 

D14

 

30 months

 

21.13.3.                       

 

No accessible mirror has been provided.

 

TR5

 

24 months

 

21.13.4.                       

 

The paper towel dispenser is inaccessible because it is mounted too high behind an obstruction.

 

CT3

 

12 months

 

21.13.5.                       

 

The lavatory is inaccessible because a foot pedal is required to operate it, and it has no knee space clearance.

 

LS1

 

30 months

 

21.13.6.                       

 

The urinal is inaccessible because the rim is 24 inches high and the flush control is higher than 44 inches.

 

TR8

 

30 months

 

21.13.7.                       

 

There is no accessible toilet stall provided.

 

TR2

 

30 months

 

21.14.     

 

Men€™s toilet room with stalls (near classroom 182):

 

 

 

 

 

21.14.1.                       

 

The toilet room sign does not have raised or Braille characters.

 

TR11

 

24 months

 

21.14.2.                       

 

The door is inaccessible because it has an opening width of 30 inches.

 

D14

 

30 months

 

21.14.3.                       

 

The lavatory is inaccessible because the hot water and drain pipes are not covered or configured to protect against contact.

 

LS2

 

30 months

 

21.14.4.                       

 

The lavatory is inaccessible because the lavatory hardware requires tight grasping and twisting to operate.

 

LS4

 

24 months

 

21.14.5.                       

 

There is no accessible toilet stall provided.

 

TR2

 

30 months

 

21.15.     

 

Men and women€™s single-user toilet rooms (near classroom 159) (existing): These toilet rooms are inaccessible. There is no signage directing people with disabilities to the accessible toilet rooms.

 

TR10

 

30 months

 

21.16.     

 

Classroom 182: The entrance door is inaccessible because knob hardware is used.

 

D2

 

24 months

 

21.17.     

 

Elevator (near offices):

 

 

 

 

 

21.17.1.                       

 

The elevator is inaccessible because the elevator doors do not automatically re-open if obstructed nor automatically re-open without contact when the obstruction is between 5 to 29 inches above the floor.

 

E6

 

30 months

 

22.               

 

Robert Anderson Water Tower and Municipal Building, 4001 S. 6th St.

 

 

 

 

 

22.1.         

 

Parking lot:

 

 

 

 

 

22.1.1.   

 

The parking lot, with a total of 70 parking spaces of which 2 are designated as van-accessible and 2 as standard accessible, is inaccessible because the van-accessible parking spaces€™ access aisles are less than 96 inches wide, and one space has a slope of 4.1%.  In addition, the signs are mounted too low.  This lot requires at least 1 van accessible space and 2 standard accessible spaces.

 

P1

 

30 months

 

22.2.         

 

Lobby elevator: The elevator is inaccessible because the hall lanterns do not emit a visual nor audible signal indicating when a car is answering a call. In addition, the hall lanterns do not signal once for up, twice for down (or have voice equivalent).

 

E10

 

30 months

 

22.3.         

 

1st floor hallway: The white metallic AED cabinet next to the directory protrudes into the walkway and is not detectable to blind persons using a cane.

 

AR7

 

12 months

 

22.4.         

 

1st floor employees area women€™s toilet room with stalls:

 

 

 

 

 

22.4.1.   

 

The door is inaccessible because it requires 10 pounds of force to open.

 

D3

 

12 months

 

22.4.2.   

 

The designated accessible toilet is inaccessible because the side grab bar is mounted with its farther end 47 inches from the rear wall.

 

TR17

 

12 months

 

22.5.         

 

1st floor employees area men€™s toilet room with stalls:

 

 

 

 

 

22.5.1.   

 

The door is inaccessible because it requires 10 pounds of force to open.

 

D3

 

12 months

 

22.5.2.   

 

The designated accessible toilet is inaccessible because the side grab bar is mounted with its farther end 47 inches from the rear wall.

 

TR17

 

12 months

 

22.6.         

 

2nd floor employees area women€™s toilet room with stalls:

 

 

 

 

 

22.6.1.   

 

The designated accessible toilet is inaccessible because the side grab bar is mounted with its farther end 47 inches from the rear wall.

 

TR17

 

12 months

 

22.7.         

 

2nd floor employees area men€™s toilet room with stalls:

 

 

 

 

 

22.7.1.   

 

The designated accessible toilet is inaccessible because the side grab bar is mounted with its farther end 47 inches from the rear wall.

 

TR17

 

12 months

 

22.8.         

 

3rd Floor Kitchenette:

 

 

 

 

 

22.8.1.   

 

The microwave oven€™s controls are inaccessible because they are mounted more than 48 inches high over an obstruction.

 

CT3

 

24 months

 

22.8.2.   

 

The sink is inaccessible because it lacks required knee and toe space.

 

LS3

 

30 months

 

22.9.         

 

3rd floor drinking fountain in community area near toilet rooms: Although a designated accessible drinking fountain is provided, there is no drinking fountain provided for people who have difficulty bending or stooping.

 

DF3

 

30 months

 

22.10.     

 

3rd floor women€™s toilet room with stalls:

 

 

 

 

 

22.10.1.                       

 

The toilet room door is inaccessible because it requires 10 pounds of force to open.

 

D3

 

12 months

 

22.10.2.                       

 

The designated accessible toilet is inaccessible because the side grab bar is mounted with its farther end 48 inches from the rear wall.

 

TR17

 

12 months

 

22.10.3.                       

 

The toilet seat cover dispenser is inaccessible because it is mounted above reach ranges beside the toilet.

 

CT3

 

12 months

 

22.11.     

 

3rd floor men€™s toilet room with stalls:

 

 

 

 

 

22.11.1.                       

 

The toilet room door is inaccessible because it requires 10 pounds of force to open.

 

D3

 

12 months

 

22.11.2.                       

 

The designated accessible toilet is inaccessible because the side grab bar is mounted with its farther end 48 inches from the rear wall.

 

TR17

 

12 months

 

22.11.3.                       

 

The toilet seat cover dispenser is inaccessible because it is mounted above reach ranges beside the toilet.

 

CT3

 

12 months

 

23.               

 

Tow Lot Office, 3811 W. Lincoln Av.

 

 

 

 

 

23.1.         

 

Parking lot:

 

 

 

 

 

23.1.1.   

 

The parking lot, with a total of 32 parking spaces of which 1 is designated as van-accessible and 1 as standard accessible, is inaccessible because the van-accessible parking space€™s access aisle is 94 inches wide. This lot requires at least 1 van accessible space and 1 standard accessible space.

 

P1

 

30 months

 

23.2.         

 

Lobby area unisex single-user toilet room:

 

 

 

 

 

23.2.1.   

 

The toilet room sign is mounted on the door.

 

TR11

 

12 months

 

23.2.2.   

 

The toilet is inaccessible because the flush control is on the closed side.

 

TR4

 

30 months

 

23.3.         

 

Drinking fountain by lobby area toilet room: Although a designated accessible drinking fountain is provided, there is no drinking fountain provided for people who have difficulty bending or stooping.

 

DF3

 

30 months

 

24.               

 

Zablocki Library, 3501 W. Oklahoma Av.

 

 

 

 

 

24.1.         

 

 

Exterior route from parking lot access aisle to sidewalk: The route is inaccessible because there is a 1 inch change in level where the access aisle meets the sidewalk.

 

AR1

 

30 months

 

24.2.         

 

Men€™s single-user toilet room:

 

 

 

 

 

24.2.1.   

 

The door is inaccessible because it requires 12 pounds of force to open.

 

D3

 

12 months

 

24.2.2.   

 

The keyed lock on the entry door is inaccessible because the controls require twisting of the wrist to operate.

 

D2

 

24 months

 

24.2.3.   

 

No accessible mirror has been provided.

 

TR5

 

24 months

 

24.2.4.   

 

The lavatory is inaccessible because the hot water and drain pipes are not insulated or otherwise configured to protect against contact.

 

LS2

 

24 months

 

24.2.5.   

 

The toilet is inaccessible because its centerline is 19 inches from the side wall.

 

TR7

 

30 months

 

24.2.6.   

 

The toilet is inaccessible because the flush control is on the closed side.

 

TR4

 

30 months

 

24.2.7.   

 

The toilet paper dispenser is inaccessible because it is mounted 42 inches from the rear wall.

 

TR6

 

12 months

 

24.2.8.   

 

The toilet is inaccessible because the side grab bar is mounted with its farthest side 47 inches from the rear wall.

 

TR17

 

12 months

 

24.3.         

 

Women€™s single-user toilet room:

 

 

 

 

 

24.3.1.   

 

The door is inaccessible because it requires 10 pounds of force to open.

 

D3

 

12 months

 

24.3.2.   

 

The keyed lock on the entry door is inaccessible because the controls require twisting of the wrist to operate.

 

D2

 

24 months

 

24.3.3.   

 

No accessible mirror has been provided.

 

TR5

 

24 months

 

24.3.4.   

 

The lavatory is inaccessible because the hot water and drain pipes are not insulated or otherwise configured to protect against contact.

 

LS2

 

24 months

 

24.3.5.   

 

The toilet is inaccessible because its centerline is 21 inches from the side wall.

 

TR7

 

30 months

 

24.3.6.   

 

The toilet is inaccessible because the side grab bar is mounted with its farthest side 47 inches from the rear wall.

 

TR17

 

12 months

 

25.               

 

Zeidler Municipal Building, 841 N. Broadway

 

 

 

 

 

25.1.         

 

Basement interior route: The defibrillator near the elevator protrudes into the walkway and is not detectable to blind persons using a cane.

 

AR7

 

12 months

 

25.2.         

 

Basement men and women€™s locker rooms (existing): The locker rooms contain a number of inaccessible elements and are not accessible to people with disabilities.

 

LR1

 

12 months

 

25.3.         

 

Basement - Mail room / print shop (B-2):

 

 

 

 

 

25.3.1.   

 

The door is inaccessible because it requires 12 pounds of force to open.

 

D3

 

12 months

 

25.3.2.   

 

The door is inaccessible because knob hardware is used.

 

D2

 

24 months

 

25.3.3.   

 

The shelf mounted on a door protrudes into the walkway and is not detectable to blind persons using a cane.

 

AR7

 

12 months

 

25.4.         

 

Basement drinking fountain (hallway):  Although a designated accessible drinking fountain is provided, there is no drinking fountain provided for people who have difficulty bending or stooping.

 

DF3

 

30 months

 

25.5.         

 

Basement men and women€™s toilet rooms with stalls (existing): There is no signage directing people with disabilities to the accessible toilet rooms.

 

TR10

 

24 months

 

25.6.         

 

Lower Parking level women€™s toilet room with stalls:

 

 

 

 

 

25.6.1.   

 

The toilet room sign has no raised or Braille characters.

 

TR11

 

24 months

 

25.6.2.   

 

The door is inaccessible because it has an opening width of 31 inches.

 

D14

 

30 months

 

25.6.3.   

 

The door is inaccessible because it requires 13 pounds of force to open.

 

D3

 

13 months

 

25.6.4.   

 

The air dryer protrudes into the walkway and is not detectable to blind persons using a cane.

 

AR7

 

12 months

 

25.6.5.   

 

The sanitary napkin dispenser is inaccessible because the controls require twisting of the wrist to operate.

 

CT2

 

24 months

 

25.6.6.   

 

The designated accessible toilet is inaccessible because its centerline is 19 inches from the side wall.

 

TR7

 

30 months

 

25.6.7.   

 

No accessible coat hook has been provided.

 

TR3

 

24 months

 

25.6.8.   

 

The designated accessible toilet is inaccessible because the side grab bar is obstructed by the toilet paper dispenser.

 

TR15

 

12 months

 

25.6.9.   

 

The designated accessible toilet is inaccessible because the side grab bar is mounted with its farther end 48 inches from the rear wall.

 

TR17

 

12 months

 

25.6.10.                       

 

 

The designated accessible toilet is inaccessible because the rear grab bar is obstructed by the flush pipe.

 

TR15

 

30 months

 

25.7.         

 

Lower Parking level men€™s toilet room with stalls:

 

 

 

 

 

25.7.1.   

 

The toilet room sign is mounted on the door with its centerline at 64 inches above the floor, and has no raised or Braille characters.

 

TR11

 

24 months

 

25.7.2.   

 

The towel dispenser protrudes into the walkway and is not detectable to blind persons using a cane.

 

AR7

 

12 months

 

25.7.3.   

 

The designated accessible toilet is inaccessible because the top of the seat is 19½ inches high.

 

TR9

 

30 months

 

25.7.4.   

 

The designated accessible toilet is inaccessible because the side grab bar is obstructed by the toilet paper dispenser.

 

TR15

 

12 months

 

25.7.5.   

 

 

The designated accessible toilet is inaccessible because the rear grab bar is obstructed by the flush pipe.

 

TR15

 

30 months

 

25.8.         

 

Lower Parking level drinking fountain:

 

 

 

 

 

25.8.1.   

 

The drinking fountain is inaccessible because the flow of water is 1 inch high.

 

DF5

 

30 months

 

25.8.2.   

 

Although a designated accessible drinking fountain is provided, there is no drinking fountain provided for people who have difficulty bending or stooping.

 

DF3

 

30 months

 

25.9.         

 

1st floor men€™s toilet room with stalls:

 

 

 

 

 

25.9.1.   

 

The air dryer protrudes into the walkway and is not detectable to blind persons using a cane.

 

AR7

 

12 months

 

25.9.2.   

 

The designated accessible toilet is inaccessible because the side grab bar is obstructed by the toilet paper dispenser.

 

TR15

 

12 months

 

25.10.     

 

1st floor women€™s toilet room with stalls:

 

 

 

 

 

25.10.1.                       

 

The sanitary napkin dispenser is inaccessible because the controls require twisting of the wrist to operate.

 

CT2

 

24 months

 

25.10.2.                       

 

The designated accessible toilet is inaccessible because the side grab bar is obstructed by the toilet paper dispenser.

 

TR15

 

12 months

 

25.10.3.                       

 

The toilet seat cover dispenser is inaccessible because it is mounted with the controls higher than 48 inches behind the toilet.

 

CT3

 

12 months

 

25.11.     

 

1st floor conference room (room 102):

 

 

 

 

 

25.11.1.                       

 

The conference room is inaccessible to people with hearing disabilities because there is no assistive listening system provided.

 

AA4

 

30 months

 

25.12.     

 

2nd floor men€™s toilet room with stalls:

 

 

 

 

 

25.12.1.                       

 

The pull side of the door, which is accessed through a front approach, is inaccessible because it has inadequate clear space on the latch side.

 

D5

 

30 months

 

25.12.2.                       

 

The shelf under the mirror protrudes into the walkway and is not detectable to blind persons using a cane.

 

AR7

 

12 months

 

25.13.     

 

2nd floor women€™s toilet room with stalls:

 

 

 

 

 

25.13.1.                       

 

The interior vestibule door is inaccessible because it requires 15 pounds of force to open.        

 

D3

 

12 months

 

25.13.2.                       

 

The sanitary napkin dispenser is inaccessible because the controls require twisting of the wrist to operate.

 

CT2

 

24 months

 

25.13.3.                       

 

The designated accessible toilet is inaccessible because the top of the seat is 20 inches high.

 

TR9

 

30 months

 

25.14.     

 

3rd floor men€™s toilet room with stalls:

 

 

 

 

 

25.14.1.                       

 

The paper towel dispenser is inaccessible because it is mounted with the controls higher than 48 inches over the lavatory.

 

CT3

 

12 months

 

25.14.2.                       

 

The air dryer protrudes into the walkway and is not detectable to blind persons using a cane.

 

AR7

 

12 months

 

25.14.3.                       

 

The designated accessible toilet is inaccessible because the top of the seat is 16½ inches high.

 

TR9

 

30 months

 

25.14.4.                       

 

The designated accessible toilet is inaccessible because the flush control is on the closed side.

 

TR4

 

30 months

 

25.14.5.                       

 

The designated accessible toilet is inaccessible because the side grab bar is mounted with its farther end 48 inches from the rear wall.

 

TR17

 

12 months

 

25.15.     

 

3rd floor women€™s toilet room with stalls:

 

 

 

 

 

25.15.1.                       

 

The sanitary napkin dispenser is inaccessible because the controls require twisting of the wrist to operate.

 

CT2

 

24 months

 

25.15.2.                       

 

The designated accessible toilet is inaccessible because the side grab bar is mounted with its farther end 48 inches from the rear wall.

 

TR17

 

12 months

 

25.16.     

 

3rd floor drinking fountains: Although two designated accessible drinking fountains are provided, there is no drinking fountain provided for people who have difficulty bending or stooping.

 

DF3

 

30 months

 

25.17.     

 

4th floor interior route: The defibrillator protrudes into the walkway and is not detectable to blind persons using a cane.

 

AR7

 

12 months

 

25.18.     

 

4th floor drinking fountains: Although two designated accessible drinking fountains are provided, there is no drinking fountain provided for people who have difficulty bending or stooping.

 

DF3

 

12 months

 

25.19.     

 

4th floor men€™s toilet room with stalls:

 

 

 

 

 

25.19.1.                       

 

The toilet room sign does not have the International Symbol of Access.

 

TR11

 

24 months

 

25.19.2.                       

 

The pull side of the toilet room door, which is accessed through a front approach, is inaccessible because it has less than 18 inches of clear space on the latch side.

 

D5

 

30 months

 

25.19.3.                       

 

No accessible mirror has been provided.

 

TR5

 

24 months

 

25.19.4.                       

 

The air dryer protrudes into the walkway and is not detectable to blind persons using a cane.

 

AR7

 

12 months

 

25.19.5.                       

 

The paper towel dispenser is inaccessible because it is mounted with the controls higher than 48 inches over the lavatory.

 

CT3

 

12 months

 

25.19.6.                       

 

The lavatory is inaccessible because the hot water and drain pipes are not insulated or otherwise configured to protect against contact.

 

LS2

 

24 months

 

25.19.7.                       

 

There is no accessible toilet stall provided.

 

TR2

 

12 months

 

25.20.     

 

4th floor women€™s toilet room with stalls:

 

 

 

 

 

25.20.1.                       

 

The toilet room sign does not have the International Symbol of Access.

 

TR11

 

24 months

 

25.20.2.                       

 

The pull side of the door, which is accessed through a front approach, is inaccessible because it has less than 18 inches of clear space on the latch side.

 

D5

 

30 months

 

25.20.3.                       

 

The sanitary napkin dispenser is inaccessible because the controls require twisting of the wrist to operate.

 

CT2

 

24 months

 

25.20.4.                       

 

The air dryer protrudes into the walkway and is not detectable to blind persons using a cane.

 

AR7

 

12 months

 

25.20.5.                       

 

The paper towel dispenser is inaccessible because it is mounted with the controls higher than 48 inches and is mounted over the lavatory.

 

CT3

 

12 months

 

25.20.6.                       

 

The lavatory is inaccessible because the hot water and drain pipes are not insulated or otherwise configured to protect against contact.

 

LS2

 

24 months

 

25.20.7.                       

 

There is no accessible toilet stall provided.

 

TR2

 

12 months

 

25.21.     

 

4th floor Water Engineering counter: The Water Engineering counter is inaccessible because it is more than 36 inches high.

 

C1

 

30 months

 

25.22.     

 

5th floor interior route: The defibrillator protrudes into the walkway and is not detectable to blind persons using a cane.

 

AR7

 

12 months

 

25.23.     

 

5th floor men€™s toilet room with stalls:

 

 

 

 

 

25.23.1.                       

 

The air dryer protrudes into the walkway and is not detectable to blind persons using a cane.

 

AR7

 

12 months

 

25.23.2.                       

 

The designated accessible toilet is inaccessible because the flush control is on the closed side.

 

TR4

 

30 months

 

25.23.3.                       

 

The toilet seat cover dispenser is inaccessible because it is mounted above reach ranges behind the toilet.

 

CT3

 

12 months

 

25.24.     

 

5th floor women€™s toilet room with stalls:

 

 

 

 

 

25.24.1.                       

 

The sanitary napkin dispenser is inaccessible because the controls require twisting of the wrist to operate.

 

CT2

 

24 months

 

25.24.2.                       

 

The toilet seat cover dispenser is inaccessible because it is mounted above reach ranges behind the toilet.

 

CT3

 

12 months

 

25.24.3.                       

 

The designated accessible toilet is inaccessible because the flush control is on the closed side.

 

TR4

 

30 months

 

25.24.4.                       

 

The designated accessible toilet is inaccessible because the side grab bar is obstructed by the toilet paper dispenser.

 

TR15

 

12 months

 

25.25.     

 

5th floor drinking fountains: Although two designated accessible drinking fountains are provided, there is no drinking fountain provided for people who have difficulty bending or stooping.

 

DF3

 

30 months

 

25.26.     

 

6th floor men€™s toilet room with stalls:

 

 

 

 

 

25.26.1.                       

 

The paper towel dispenser is inaccessible because it is mounted with the controls higher than 48 inches over the lavatory.

 

CT3

 

12 months

 

25.26.2.                       

 

The air dryer protrudes into the walkway and is not detectable to blind persons using a cane.

 

AR7

 

12 months

 

25.26.3.                       

 

The designated accessible toilet is inaccessible because the flush control is on the closed side.

 

TR4

 

30 months

 

25.26.4.                       

 

The designated accessible toilet is inaccessible because the side grab bar is obstructed by the toilet paper dispenser.

 

TR15

 

12 months

 

25.27.     

 

6th floor women€™s toilet room with stalls:

 

 

 

 

 

25.27.1.                       

 

The sanitary napkin dispenser is inaccessible because the controls require twisting of the wrist to operate.

 

CT2

 

24 months

 

25.27.2.                       

 

The paper towel dispenser is inaccessible because it is mounted with the controls higher than 48 inches over the lavatory.

 

CT3

 

12 months

 

25.27.3.                       

 

The toilet seat cover dispenser is inaccessible because it is mounted with the controls higher than 48 inches behind the toilet.

 

CT3

 

12 months

 

25.27.4.                       

 

The designated accessible toilet is inaccessible because the flush control is on the closed side.

 

TR4

 

30 months

 

25.27.5.                       

 

The designated accessible toilet is inaccessible because the side grab bar is obstructed by the toilet paper dispenser.

 

TR15

 

12 months

 

25.28.     

 

6th floor drinking fountain:

 

 

 

 

 

25.28.1.                       

 

Although two designated accessible drinking fountains are provided, there is no drinking fountain provided for people who have difficulty bending or stooping.

 

DF3

 

30 months

 

25.28.2.                       

 

The drinking fountains protrude into the walkway and are not detectable to blind persons using a cane.

 

AR7

 

12 months

 

25.29.     

 

7th floor interior route: The defibrillator protrudes into the walkway and is not detectable to blind persons using a cane.

 

AR7

 

12 months

 

25.30.     

 

7th floor drinking fountains: Although two designated accessible drinking fountains are provided, there is no drinking fountain provided for people who have difficulty bending or stooping.

 

DF3

 

30 months

 

25.31.     

 

7th floor women€™s toilet room with stalls:

 

 

 

 

 

25.31.1.                       

 

The paper towel dispenser is inaccessible because it is mounted with the controls higher than 48 inches over the lavatory.

 

CT3

 

12 months

 

25.31.2.                       

 

The sanitary napkin dispenser is inaccessible because the controls require twisting of the wrist to operate.

 

CT2

 

24 months

 

25.31.3.                       

 

The toilet seat cover dispenser is inaccessible because it is mounted above 48 inches high behind the toilet.

 

CT3

 

12 months

 

25.31.4.                       

 

The designated accessible toilet is inaccessible because the top of the seat is 16½ inches high.

 

TR9

 

30 months

 

25.31.5.                       

 

The designated accessible toilet is inaccessible because the flush control is on the closed side.

 

TR4

 

30 months

 

25.31.6.                       

 

The designated accessible toilet is inaccessible because the side grab bar is obstructed by the toilet paper dispenser.

 

TR15

 

12 months

 

25.32.     

 

7th floor men€™s toilet room with stalls:

 

 

 

 

 

25.32.1.                       

 

The paper towel dispenser is inaccessible because it is mounted with the controls higher than 48 inches over the lavatory.

 

CT3

 

12 months

 

25.32.2.                       

 

The designated accessible toilet is inaccessible because the top of the seat is 15½ inches high.

 

TR9

 

30 months

 

25.32.3.                       

 

The designated accessible toilet is inaccessible because the flush control is on the closed side.

 

TR4

 

30 months

 

25.32.4.                       

 

The designated accessible toilet is inaccessible because the side grab bar is obstructed by the toilet paper dispenser.

 

TR15

 

12 months

 

25.33.     

 

8th floor women€™s toilet room with stalls:

 

 

 

 

 

25.33.1.                       

 

The sanitary napkin dispenser is inaccessible because the controls require twisting of the wrist to operate.

 

CT2

 

24 months

 

25.33.2.                       

 

The paper towel dispenser is inaccessible because it is mounted with the controls higher than 48 inches over the lavatory.

 

CT3

 

12 months

 

25.33.3.                       

 

The toilet seat cover dispenser is inaccessible because it is mounted with the controls higher than 48 inches behind the toilet.

 

CT3

 

12 months

 

25.33.4.                       

 

The designated accessible toilet is inaccessible because the top of the seat is 16 inches high.

 

TR9

 

30 months

 

25.33.5.                       

 

The designated accessible toilet is inaccessible because the flush control is on the closed side.

 

TR4

 

30 months

 

25.34.     

 

8th floor men€™s toilet room with stalls:

 

 

 

 

 

25.34.1.                       

 

The paper towel dispenser is inaccessible because it is mounted with the controls higher than 48 inches over the lavatory.

 

CT3

 

12 months

 

25.34.2.                       

 

The designated accessible toilet is inaccessible because the flush control is on the closed side.

 

TR4

 

30 months

 

25.34.3.                       

 

The designated accessible toilet is inaccessible because the side grab bar is obstructed by the toilet paper dispenser.

 

TR15

 

12 months

 

25.34.4.                       

 

The designated accessible toilet is inaccessible because the side grab bar is mounted 50 inches from the rear wall.

 

TR17

 

12 months

 

25.35.     

 

8th floor Map Sales office: The counter is inaccessible because it is 42¾ inches high.

 

C1

 

30 months

 

25.36.     

 

9th floor interior route: The defibrillator protrudes into the walkway and is not detectable to blind persons using a cane.

 

AR7

 

12 months

 

25.37.     

 

9th floor women€™s toilet room with stalls:

 

 

 

 

 

25.37.1.                       

 

The paper towel dispenser (nearest the lavatory that has pipe protection) is inaccessible because it is mounted with the controls higher than 48 inches over the lavatory.

 

CT3

 

12 months

 

25.37.2.                       

 

The sanitary napkin dispenser is inaccessible because the controls require twisting of the wrist to operate.                 

 

CT2

 

24 months

 

25.37.3.                       

 

The designated accessible toilet is inaccessible because the flush control is on the closed side.

 

TR4

 

30 months

 

25.37.4.                       

 

No accessible coat hook has been provided.

 

TR3

 

24 months

 

25.38.     

 

9th floor men€™s toilet room with stalls:

 

 

 

 

 

25.38.1.                       

 

The pull side of the door, which is accessed through a front approach, is inaccessible because it has less than 18 inches of clear space on the latch side.

 

D5

 

30 months

 

25.38.2.                       

 

The paper towel dispenser is inaccessible because it is mounted with the controls higher than 48 inches over the lavatory.

 

CT3

 

12 months

 

25.38.3.                       

 

The lavatory is inaccessible because the hot water and drain pipes are not insulated or otherwise configured to protect against contact.

 

LS2

 

24 months

 

25.38.4.                       

 

The designated accessible toilet is inaccessible because the top of the seat is 16½ inches high.

 

TR9

 

30 months

 

25.38.5.                       

 

The designated accessible toilet is inaccessible because the flush control is on the closed side.

 

TR4

 

30 months

 

25.38.6.                       

 

No accessible coat hook has been provided.

 

TR3

 

24 months

 

25.38.7.                       

 

The designated accessible toilet is inaccessible because the side grab bar is obstructed by the toilet paper dispenser.

 

TR15

 

12 months

 

25.39.     

 

9th floor Planning and Development / Permits office: The counter is inaccessible because it is 42 ¼ inches high.

 

C1

 

30 months

 

25.40.     

 

9th floor Special Assessment / Estimating office: The counter is inaccessible because it is 42¼ inches high.

 

C1

 

30 months

 

25.41.     

 

10th floor interior route: The defibrillator protrudes into the walkway and is not detectable to blind persons using a cane.

 

AR7

 

12 months

 

25.42.     

 

10th floor men€™s toilet room with stalls:

 

 

 

 

 

25.42.1.                       

 

The toilet room sign is mounted above the door.

 

TR11

 

12 months

 

25.42.2.                       

 

The air dryer protrudes into the walkway and is not detectable to blind persons using a cane.

 

AR7

 

12 months

 

25.42.3.                       

 

The toilet seat cover dispenser is inaccessible because it is mounted more than 48 inches high behind the toilet.

 

CT3

 

12 months

 

25.43.     

 

10th floor women€™s toilet room with stalls:

 

 

 

 

 

25.43.1.                       

 

The sanitary napkin dispenser is inaccessible because the controls require twisting of the wrist to operate.

 

CT2

 

24 months

 

25.43.2.                       

 

The toilet seat cover dispenser is inaccessible because it is mounted more than 48 inches high behind the toilet.

 

CT3

 

12 months

 

25.44.     

 

10th floor drinking fountains:

 

 

 

 

 

25.44.1.                       

 

The drinking fountain is inaccessible because the controls require tight grasping and twisting to operate, and the controls also require more than 5 pounds of pressure to operate.

 

DF2

 

24 months

 

25.44.2.                       

 

Although a designated accessible drinking fountain is provided, there is no drinking fountain provided for people who have difficulty bending or stooping.

 

DF3

 

30 months

 

25.44.3.                       

 

The drinking fountains protrude into the walkway and are not detectable to blind persons using a cane.

 

AR7

 

12 months

 

25.44.4.                       

 

10th floor Dept of Neighborhood Services office: The counter is inaccessible because it is 42¼ inches high.

 

C1

 

30 months