ATTACHMENT J: Modifications to Altered Facilities
Please Note: Paragraph 58 of the Settlement Agreement requires that within one (1) year of the effective date of this Agreement, the City of Milwaukee provide signage as necessary to comply with 28 C.F.R. § 35.163(b), after having surveyed all facilities that are the subject of this Agreement for the purpose of identifying those that have multiple entrances not all of which are accessible.
The chart below lists the facilities surveyed by the Department, the access issues identified during the survey, and the actions required to correct the access issues. Required actions are listed using an alphanumeric code. The key to the alphanumeric codes is provided in Attachment M to this Agreement.
In order to ensure that the following spaces and elements in the City€™s facilities in which alterations occurred after January 26, 1992, are readily accessible to and usable by persons with disabilities, the City will take the actions referenced by the alphanumeric code and described in detail in Attachment M to this Settlement Agreement within the time period specified below, which time period will begin to run on the effective date of this Agreement. |
|||
Item # |
Access Issue |
Required Action |
Completion Date |
1. |
City Hall, 200 E. Wells |
|
|
1.1. |
Entrances (generally): |
|
|
1.1.1. |
The building does not have directional signage posted at some of the inaccessible entrances and does not have the International Symbol of Accessibility posted at accessible entrances. |
D10 |
12 months |
1.2. |
Tunnel to Zeider Municipal Building: The top segment of the ramp closest to City Hall, with a 5.6% slope, is inaccessible because it lacks handrails on both sides of the segment. |
R2 |
24 months |
1.3. |
Basement men€™s toilet room with stalls (near Room B1): |
|
|
1.3.1. |
The hand dryer protrudes into the walkway and is not detectable to blind persons using a cane. |
AR7 |
12 months |
1.3.2. |
The designated accessible toilet is inaccessible because the side grab bar is mounted with its farther end 48 inches from the rear wall. |
TR17 |
30 months |
1.4. |
Basement women€™s toilet room with stalls (near Room B1): |
|
|
1.4.1. |
No accessible coat hook has been provided. |
TR3 |
12 months |
1.4.2. |
The designated accessible toilet is inaccessible because the side grab bar is mounted with its farther end 48 inches from the rear wall. |
TR17 |
12 months |
1.5. |
Basement drinking fountain near Room B1: |
|
|
1.5.1. |
The drinking fountain is inaccessible because it has a spout that is 37¼ inches high. |
DF3 |
30 months |
1.5.2. |
Although a designated accessible drinking fountain is provided, there is no drinking fountain provided for people who have difficulty bending or stooping. |
DF3 |
30 months |
1.5.3. |
The drinking fountain protrudes into the walkway and is not detectable to blind persons using a cane. |
AR7 |
12 months |
1.6. |
1st floor women€™s toilet room with stalls: |
|
|
1.6.1. |
No accessible mirror has been provided. |
TR5 |
12 months |
1.6.2. |
The baby changing station is inaccessible because it is mounted with the handle more than 54 inches high. |
DW1 |
12 months |
1.6.3. |
The baby changing station is inaccessible because it does not have adequate clear floor space in front of it. |
AR10 |
12 months |
1.6.4. |
The toilet seat cover dispenser is inaccessible because it is mounted 51 inches high behind the toilet. |
CT3 |
12 months |
1.6.5. |
The designated accessible toilet is inaccessible because the side grab bar is mounted with its farther end 50 inches from the rear wall. |
TR17 |
12 months |
1.7. |
1st floor men€™s toilet room with stalls: |
|
|
1.7.1. |
The toilet room sign has no raised or Braille characters. |
TR11 |
12 months |
1.7.2. |
No accessible mirror has been provided. |
TR5 |
12 months |
1.8. |
1st floor City Treasurer€™s Office: The room number signage provided is inaccessible because it does not have raised and Braille characters. |
D15 |
12 months |
1.9. |
2nd floor interior route: |
|
|
1.9.1. |
The hallway defibrillator protrudes into the walkway and is not detectable to blind persons using a cane. |
AR7 |
12 months |
1.9.2. |
The sprinkler valve protrudes into the walkway and is not detectable to blind persons using a cane. |
AR7 |
12 months |
1.10. |
2nd floor drinking fountain: |
|
|
1.10.1. |
The drinking fountain is inaccessible because it has a spout that is 37½ inches high, it does not have adequate knee and toe clearance, and the controls require tight grasping and twisting to operate. |
DF1 |
30 months |
1.10.2. |
Although a designated accessible drinking fountain is provided, there is no drinking fountain provided for people who have difficulty bending or stooping. |
DF3 |
30 months |
1.10.3. |
The drinking fountain protrudes into the walkway and is not detectable to blind persons using a cane. |
AR7 |
12 months |
1.11. |
2nd floor men€™s toilet room with stalls: |
|
|
1.11.1. |
The toilet room sign has no raised or Braille characters, and is mounted on the door. In addition, although this toilet room has accessible features, the signage directs people with disabilities to a different toilet room. |
TR11 |
12 months |
1.12. |
2nd floor women€™s toilet room with stalls: |
|
|
1.12.1. |
The toilet room sign has no raised or Braille characters, and is mounted on the door. In addition, although this toilet room has accessible features, the signage directs people with disabilities to a different toilet room. |
TR11 |
12 months |
1.13. |
3rd floor interior route: The defibrillator protrudes into the walkway and is not detectable to blind persons using a cane. |
AR7 |
12 months |
1.14. |
3rd floor drinking fountain: |
|
|
1.14.1. |
The drinking fountain is inaccessible because it has a spout that is 37 inches high, it does not have adequate knee and toe clearance, and the controls require tight grasping and twisting to operate. |
DF1 |
30 months |
1.14.2. |
Although a designated accessible drinking fountain is provided, there is no drinking fountain provided for people who have difficulty bending or stooping. |
DF3 |
30 months |
1.14.3. |
The drinking fountain protrudes into the walkway and is not detectable to blind persons using a cane. |
AR7 |
12 months |
1.15. |
3rd floor women€™s toilet room with stalls: |
|
|
1.15.1. |
The toilet room sign has no raised or Braille characters and is mounted on the door. In addition, although this toilet room has accessible features, the signage directs people with disabilities to a different toilet room. |
TR11 |
12 months |
1.15.2. |
The toilet seat cover dispenser is inaccessible because it is mounted 56 inches high behind the toilet. |
CT3 |
12 months |
1.15.3. |
No accessible coat hook has been provided. |
TR3 |
24 months |
1.16. |
3rd floor men€™s toilet room with stalls: |
|
|
1.16.1. |
The toilet room sign has no raised or Braille characters and is mounted on the door. In addition, although this toilet room has accessible features, the signage directs people with disabilities to a different toilet room. |
TR11 |
12 months |
1.16.2. |
The designated accessible toilet is inaccessible because the top of the seat is 19½ inches high. |
TR9 |
30 months |
1.17. |
3rd floor Common Council Hearing Room A: The room is inaccessible to people with hearing disabilities because there is no assistive listening system provided. This room requires 3 receivers of which two are hearing-aid compatible. |
AA4 |
30 months |
1.18. |
3rd floor Common Council Hearing Room B: The room is inaccessible to people with hearing disabilities because there is no assistive listening system provided. This room requires 4 receivers of which two are hearing-aid compatible. |
AA4 |
30 months |
1.19. |
Common Council Chamber: |
|
|
1.19.1. |
The Common Council Chamber is inaccessible to people with hearing disabilities because there is no assistive listening system provided. |
AA4 |
30 months |
1.20. |
Common Council Chamber drinking fountain: |
|
|
1.20.1. |
The drinking fountain is inaccessible because it has a spout that is 41¼ inches high, has inadequate knee and toe clearance, and has inadequate clear floor space in front of the fountain. |
DF1 |
30 months |
1.21. |
4th floor interior route: The hallway defibrillator protrudes into the walkway and is not detectable to blind persons using a cane. |
AR7 |
12 months |
1.22. |
4th floor women€™s toilet room with stalls: |
|
|
1.22.1. |
The toilet room sign is not mounted with its tactile characters between 48 and 60 inches high. |
TR11 |
12 months |
1.22.2. |
The sanitary napkin dispenser is inaccessible because the controls require twisting of the wrist to operate. |
CT2 |
24 months |
1.22.3. |
The sanitary napkin dispenser protrudes into the walkway and is not detectable to blind persons using a cane. |
AR7 |
12 months |
1.22.4. |
The paper towel dispenser by the window protrudes into the walkway and is not detectable to blind persons using a cane. |
AR7 |
12 months |
1.22.5.
|
The designated accessible toilet is inaccessible because the side grab bar is mounted with its farther end 51 inches from the rear wall. |
TR17 |
24 months |
1.23. |
4th floor men€™s toilet room with stalls: |
|
|
1.23.1. |
The toilet room sign is not mounted with its tactile characters between 48 and 60 inches high. |
TR11 |
12 months |
1.23.2. |
No accessible mirror has been provided. |
TR5 |
24 months |
1.24. |
5th floor interior route: The defibrillator protrudes into the walkway and is not detectable to blind persons using a cane. |
AR7 |
12 months |
1.25. |
5th floor women€™s toilet room with stalls: |
|
|
1.25.1. |
The toilet room sign is not mounted with its tactile characters between 48 and 60 inches high. |
TR11 |
12 months |
1.25.2. |
The sanitary napkin dispenser is inaccessible because the controls require twisting of the wrist to operate. |
CT2 |
24 months |
1.25.3. |
The sanitary napkin dispenser protrudes into the walkway and is not detectable to blind persons using a cane. |
AR7 |
12 months |
1.25.4. |
The designated accessible toilet is inaccessible because the flush control is on the closed side. |
TR4 |
30 months |
1.25.5. |
The toilet seat cover dispenser is inaccessible because it is mounted 55 inches high behind the toilet. |
CT3 |
12 months |
1.25.6.
|
The designated accessible toilet is inaccessible because the side grab bar is mounted with its farther end 51 inches from the rear wall. |
TR17 |
12 months |
1.26. |
5th floor men€™s toilet room with stalls: |
|
|
1.26.1. |
The toilet room sign is not mounted with its tactile characters between 48 and 60 inches high. |
TR11 |
12 months |
1.26.2. |
The toilet seat cover dispenser is inaccessible because it is mounted 57 inches high behind the toilet. |
TR6 |
12 months |
1.26.3. |
The designated accessible toilet is inaccessible because the side grab bar is obstructed by the toilet paper dispenser. |
TR15 |
12 months |
1.27. |
5th floor Election Commission office (Room 501): The counter is inaccessible because it is 42 inches high. |
C1 |
30 months |
1.28. |
6th floor interior route: The defibrillator protrudes into the walkway and is not detectable to blind persons using a cane. |
AR7 |
12 months |
1.29. |
6th floor drinking fountains: The drinking fountains protrude into the walkway and are not detectable to blind persons using a cane. |
AR7 |
12 months |
1.30. |
6th floor men€™s toilet room with stalls: |
|
|
1.30.1. |
The toilet room sign is not mounted with its tactile characters between 48 and 60 inches high. |
TR11 |
12 months |
1.30.2. |
The toilet seat cover dispenser is inaccessible because it is mounted 59 inches high behind the toilet. |
TR6 |
12 months |
1.31. |
6th floor women€™s toilet room with stalls: |
|
|
1.31.1. |
The toilet room sign is not mounted with its tactile characters between 48 and 60 inches high. |
TR11 |
12 months |
1.31.2. |
The toilet seat cover dispenser is inaccessible because it is mounted 59 inches high behind the toilet. |
TR6 |
12 months |
1.32. |
7th floor interior route: The defibrillator protrudes into the walkway and is not detectable to blind persons using a cane. |
AR7 |
12 months |
1.33. |
7th floor men€™s toilet room with stalls: |
|
|
1.33.1. |
The toilet room sign is not mounted with its tactile characters between 48 and 60 inches high. |
TR11 |
12 months |
1.34. |
7th floor women€™s toilet room with stalls: |
|
|
1.34.1. |
The toilet room sign is not mounted with its tactile characters between 48 and 60 inches high. |
TR11 |
12 months |
1.34.2. |
The toilet seat cover dispenser is inaccessible because it is mounted 55 inches high behind the toilet. |
TR6 |
12 months |
1.34.3. |
The designated accessible toilet is inaccessible because the flush control is on the closed side. |
TR4 |
30 months |
1.34.4. |
No accessible coat hook has been provided. |
TR3 |
24 months |
1.35. |
8th floor interior route (existing): The defibrillator protrudes into the walkway and is not detectable to blind persons using a cane. |
AR7 |
30 months |
1.36. |
8th floor drinking fountain (existing): |
|
|
1.36.1. |
The drinking fountain is inaccessible because it has inadequate knee and toe clearance. |
DF4 |
30 months |
1.36.2. |
Although a designated accessible drinking fountain is provided, there is no drinking fountain provided for people who have difficulty bending or stooping. |
DF3 |
30 months |
1.36.3. |
The drinking fountain protrudes into the walkway and is not detectable to blind persons using a cane. |
AR7 |
30 months |
1.37. |
8th floor men and women€™s toilet rooms (existing): These toilet rooms are not accessible. There is no signage directing people with disabilities to the accessible toilet rooms. |
TR10 |
30 months |
2. |
26th and Medford Playground, 2476 N. 26th St. |
|
|
2.1. |
Exterior route: |
|
|
2.1.1. |
The route where the sidewalk meets the playground surface is inaccessible because there is a gap of several inches between the concrete and the playground€™s firm surface. |
AR1 |
30 months |
2.1.2. |
The route to the swings is inaccessible because it is not firm, stable, and slip-resistant. |
AR1 |
30 months |
2.1.3. |
There are no firm, stable, and slip-resistant spaces alongside the benches to allow a transfer. |
PG1 |
30 months |
3. |
45th and Keefe Playground, 3512 N. 45th St. |
|
|
3.1.
|
Exterior route: The route leading into the playground from the street is inaccessible because there are slopes of up to 9.6% and cross-slopes of up to 8.6% along the route. |
AR1 |
30 months |
4. |
84th and Burbank Playground, 6671 N. 84th St. |
|
|
4.1. |
Exterior route: |
|
|
4.1.1. |
The route where the sidewalk meets the playground is inaccessible because there are changes in level of two inches between the concrete and where it meets the playground€™s firm surface. |
AR1 |
30 months |
4.1.2. |
The route where the sidewalk meets the swing surface is inaccessible because there are changes in level of two inches between the concrete and where it meets the swing area€™s firm surface. |
AR1 |
30 months |
5. |
90th and Bender Playground, 8900 W. Bender St. |
|
|
5.1. |
Curb ramp near 90th / Bender: The curb ramp is inaccessible because its flared sides have slopes of up to 17.3%. |
AR4 |
30 months |
5.2. |
Bleachers: |
|
|
5.2.1. |
The route to the bleachers is inaccessible because it is not firm, stable, and slip-resistant. |
AR1 |
30 months |
5.2.2. |
The bleachers are inaccessible because no wheelchair seating areas are provided. |
AA6 |
30 months |
5.3. |
Swings: The route to the swings is inaccessible because it is not firm, stable, or slip-resistant. |
AR1 |
30 months |
6. |
809 Broadway Building, 809 N. Broadway |
|
|
6.1. |
Tunnel to 809 Broadway from Zeidler Municipal Building: No accessible handrails are provided. |
R2 |
24 months |
6.2. |
Rear exterior entrance leading to basement: The interior vestibule entry door is inaccessible because it requires 12 pounds of force to open. |
D3 |
12 months |
6.3.
|
Basement men€™s and women€™s employees-only toilet rooms near rear exterior entrance (existing): There is no signage directing people with disabilities to the accessible toilet rooms. |
TR10 |
24 months |
6.4. |
Exterior Ramp to Broadway Street Entrance: The ramp is inaccessible because the handrails lack 12 inch extensions at the bottom of the ramp. |
R2 |
24 months |
6.5. |
1st floor board room (room 111): The board room is inaccessible to people with hearing disabilities because there is no assistive listening system provided. |
AA4 |
30 months |
6.6. |
1st floor glass interior doors leading to Zoning Appeals / Development Center counters: The doors are inaccessible because they require 15 pounds of force to open. |
D3 |
12 months |
6.7. |
1st floor women€™s toilet room with stalls: |
|
|
6.7.1. |
The entrance door is inaccessible because it requires more than 5 pounds of force to open. |
D3 |
12 months |
6.7.2. |
No accessible mirror has been provided. |
TR5 |
24 months |
6.7.3. |
The sanitary napkin dispenser is inaccessible because the controls require twisting of the wrist to operate. |
CT2 |
24 months |
6.7.4. |
The lavatory is inaccessible because the top of the rim or counter is 34½ inches high. |
LS3 |
30 months |
6.7.5. |
No accessible coat hook has been provided. |
TR3 |
24 months |
6.7.6. |
The designated accessible toilet is inaccessible because the side grab bar is 36 inches long and it is mounted with the farther end 45 inches from the rear wall. |
TR17 |
12 months |
6.8. |
1st floor men€™s toilet room with stalls: |
|
|
6.8.1. |
The entrance door is inaccessible because it requires more than 5 pounds of force to open. |
D3 |
12 months |
6.8.2. |
No accessible mirror has been provided. |
TR5 |
24 months |
6.8.3. |
The paper towel dispenser protrudes into the walkway and is not detectable to blind persons using a cane. |
AR7 |
12 months |
6.8.4. |
The urinal is inaccessible because the rim is 23 inches high. |
TR8 |
30 months |
6.8.5. |
No accessible coat hook has been provided. |
TR3 |
24 months |
6.8.6.
|
The designated accessible toilet is inaccessible because the side grab bar is 36 inches long and it is mounted with the farther end 44½ inches from the rear wall. |
TR17 |
12 months |
6.9. |
1st floor drinking fountain near toilet rooms: Although a designated accessible drinking fountain is provided, there is no drinking fountain provided for people who have difficulty bending or stooping. |
DF3 |
30 months |
6.10. |
1st floor interior route near toilet rooms: The fire extinguisher sign near the toilet rooms protrudes into the walkway and is not detectable to blind persons using a cane. |
AR7 |
12 months |
6.11. |
2nd floor conference rooms 2 East and 2 West: The entry doors are inaccessible because knob hardware is used. |
D2 |
24 months |
6.12. |
2nd floor men€™s toilet room with stalls: |
|
|
6.12.1. |
The toilet room sign is mounted on the wall on the hinge side of the door and does not have the international symbol of access. |
TR11 |
12 months |
6.12.2. |
The door is inaccessible because it requires 20 pounds of force to open. |
D3 |
12 months |
6.12.3. |
Although an audible alarm is provided in this facility, there is no visual alarm appliance in the toilet room. |
AL1 |
30 months |
6.12.4. |
No accessible mirror has been provided. |
TR5 |
24 months |
6.12.5. |
The towel dispenser protrudes into the walkway and is not detectable to blind persons using a cane. |
AR7 |
12 months |
6.12.6. |
The urinal is inaccessible because the rim is 24 inches high. |
TR8 |
30 months |
6.12.7. |
The designated accessible toilet stall is inaccessible because it is 48 inches wide. |
TR23 |
30 months |
6.12.8. |
The designated accessible toilet is inaccessible because the flush control is on the closed side. |
TR4 |
30 months |
6.12.9. |
The toilet paper dispenser in the designated accessible stall is inaccessible because it is mounted on the incorrect side wall. |
TR6 |
24 months |
6.12.10. |
The designated accessible toilet is inaccessible because the side grab bar is 36 inches long and it is mounted with its farther end 45 inches from the rear wall. |
TR17 |
12 months |
6.12.11. |
There is no rear grab bar provided at the designated accessible toilet. |
TR13 |
24 months |
6.13. |
2nd floor women€™s toilet room with stalls: |
|
|
6.13.1. |
The toilet room sign is mounted on the hinge side of the door and does not have the international symbol of access. |
TR11 |
12 months |
6.13.2. |
The door is inaccessible because it requires 20 pounds of force to open. |
D3 |
12 months |
6.13.3. |
Although an audible alarm is provided in this facility, there is no visual alarm appliance in the toilet room. |
AL1 |
30 months |
6.13.4. |
No accessible mirror has been provided. |
TR5 |
24 months |
6.13.5. |
The sanitary napkin dispenser is inaccessible because the controls require twisting of the wrist to operate. |
CT2 |
24 months |
6.13.6. |
The designated accessible toilet stall is inaccessible because it is 47 inches wide. |
TR23 |
30 months |
6.13.7. |
The pull side of the toilet compartment door, which is accessed through a front approach, is inaccessible because it does not have 18 inches minimum of clear space on the latch side. |
D5 |
30 months |
6.13.8. |
No accessible coat hook has been provided. |
TR3 |
24 months |
6.13.9. |
The toilet paper dispenser in the designated accessible stall is inaccessible because it is mounted on the incorrect side wall. |
TR6 |
12 months |
6.13.10. |
The designated accessible toilet is inaccessible because the side grab bar is 36 inches long and it is mounted with its farther end 45 inches from the rear wall. |
TR17 |
12 months |
6.13.11. |
There is no rear grab bar provided at the designated accessible toilet. |
TR13 |
24 months |
6.14. |
2nd floor drinking fountain between toilet rooms: |
|
|
6.14.1. |
The drinking fountain is inaccessible because it has a spout that is 37 inches high. |
DF3 |
30 months |
6.14.2. |
Although a designated accessible drinking fountain is provided, there is no drinking fountain provided for people who have difficulty bending or stooping. |
DF3 |
30 months |
6.14.3. |
The drinking fountain protrudes into the walkway and is not detectable to blind persons using a cane. |
AR7 |
12 months |
6.15. |
3rd floor interior route near elevator: The fire extinguisher sign near the elevator protrudes into the walkway and is not detectable to blind persons using a cane. |
AR7 |
12 months |
6.16. |
3rd floor conference rooms 3 East and 3 West: The entry doors are inaccessible because knob hardware is used. |
D2 |
24 months |
6.17. |
3rd floor men€™s toilet room with stalls: |
|
|
6.17.1. |
The door is inaccessible because it requires 10 pounds of force to open. |
D3 |
12 months |
6.17.2. |
Although an audible alarm is provided in this facility, there is no visual alarm appliance in the toilet room. |
AL1 |
30 months |
6.17.3. |
No accessible mirror has been provided. |
TR5 |
24 months |
6.17.4. |
The towel dispenser protrudes into the walkway and is not detectable to blind persons using a cane. |
AR7 |
12 months |
6.17.5. |
The urinal is inaccessible because the rim is 24 inches high. |
TR8 |
30 months |
6.17.6. |
The designated accessible toilet stall is inaccessible because it is 48 inches wide. |
TR23 |
30 months |
6.17.7. |
No accessible coat hook has been provided. |
TR3 |
24 months |
6.17.8. |
The designated accessible toilet is inaccessible because the flush control is on the closed side. |
TR4 |
30 months |
6.17.9. |
The toilet paper dispenser in the designated accessible stall is inaccessible because it is mounted on the incorrect side wall. |
TR6 |
12 months |
6.17.10. |
The designated accessible toilet is inaccessible because the side grab bar is 36 inches long and it is mounted with its farther end 46 inches from the rear wall. |
TR17 |
12 months |
6.17.11. |
There is no rear grab bar provided at the designated accessible toilet. |
TR13 |
24 months |
6.18. |
3rd floor women€™s toilet room with stalls: |
|
|
6.18.1. |
The toilet room sign is mounted on the door. |
TR11 |
12 months |
6.18.2. |
The door is inaccessible because it requires 14 pounds of force to open. |
D3 |
12 months |
6.18.3. |
Although an audible alarm is provided in this facility, there is no visual alarm appliance in the toilet room. |
AL1 |
30 months |
6.18.4. |
No accessible mirror has been provided. |
TR5 |
24 months |
6.18.5. |
The sanitary napkin dispenser is inaccessible because the controls require twisting of the wrist to operate. |
CT2 |
24 months |
6.18.6. |
The pull side of the toilet compartment door, which is accessed through a front approach, is inaccessible because it does not have 18 inches minimum of clear space on the latch side. |
D5 |
30 months |
6.18.7. |
The toilet seat cover dispenser is inaccessible because it is mounted 60½ inches high behind the toilet. |
CT3 |
12 months |
6.18.8. |
The designated accessible toilet stall is inaccessible because it is 46 inches wide and 60 inches deep. |
TR23 |
30 months |
6.18.9. |
No accessible coat hook has been provided. |
TR3 |
24 months |
6.18.10. |
The toilet paper dispenser in the designated accessible stall is inaccessible because it is mounted on the incorrect side wall. |
TR6 |
12 months |
6.18.11. |
The designated accessible toilet is inaccessible because the side grab bar is 36 inches long and it is mounted with its farther end 40 inches from the rear wall. |
TR17 |
12 months |
6.18.12. |
There is no rear grab bar provided at the designated accessible toilet. |
TR13 |
24 months |
6.19. |
3rd floor drinking fountain between toilet rooms: |
|
|
6.19.1. |
Although a designated accessible drinking fountain is provided, there is no drinking fountain provided for people who have difficulty bending or stooping. |
DF3 |
30 months |
6.19.2. |
The drinking fountain protrudes into the walkway and is not detectable to blind persons using a cane. |
AR7 |
12 months |
7. |
Atkinson Library, 1960 W. Atkinson Av. |
|
|
7.1. |
Parking: The parking lot is inaccessible because the access aisle is not of the required width for the entire length of the accompanying parking space. |
P2 |
30 months |
7.2. |
Exterior route from parking to the main entrance: The route is inaccessible because there is a level change exceeding ½ inch where the access aisle meets the sidewalk. |
AR1 |
30 months |
7.3. |
Book return: The book return depository is inaccessible because the clear floor space is obstructed by the arc of the entrance door swing. |
AR10 |
12 months |
7.4. |
Women€™s single-user toilet room: |
|
|
7.4.1. |
The toilet room sign has no raised or Braille characters. |
TR11 |
12 months |
7.4.2. |
The pull side of the door, which is accessed through a front approach, is inaccessible because it has less than 18 inches of clear space on the latch side. |
D5 |
30 months |
7.4.3. |
No accessible mirror has been provided. |
TR5 |
24 months |
7.4.4. |
The lavatory is inaccessible because the hot water and drain pipes are not insulated or otherwise configured to protect against contact. |
LS2 |
24 months |
7.4.5. |
The air hand dryer protrudes into the walkway and is not detectable to blind persons using a cane. |
AR7 |
12 months |
7.4.6. |
The toilet is inaccessible because the top of the seat is 19½ inches high. |
TR9 |
30 months |
7.4.7. |
The toilet is inaccessible because its centerline is 18¾ inches from the side wall. |
TR7 |
30 months |
7.4.8.
|
The sanitary napkin dispenser is inaccessible because the controls require twisting of the wrist to operate. |
CT2 |
24 months |
7.5. |
Men€™s single-user toilet room: |
|
|
7.5.1. |
The toilet room sign has no raised or Braille characters. |
TR11 |
12 months |
7.5.2. |
The pull side of the door, which is accessed through a front approach, is inaccessible because it has less than 12 inches of clear space on the latch side. |
D5 |
30 months |
7.5.3. |
No accessible mirror has been provided. |
TR5 |
24 months |
7.5.4. |
The lavatory is inaccessible because the hot water and drain pipes are not insulated or otherwise configured to protect against contact. |
LS2 |
24 months |
7.5.5. |
The lavatory is inaccessible because it has twist-type hardware. |
LS4 |
30 months |
7.5.6. |
The air hand dryer protrudes into the walkway and is not detectable to blind persons using a cane. |
AR7 |
12 months |
7.5.7. |
The toilet is inaccessible because the flush control is on the closed side. |
TR4 |
30 months |
7.5.8. |
The toilet is inaccessible because its centerline is 19½ inches from the side wall. |
TR7 |
30 months |
7.6. |
Drinking fountain near toilet rooms: |
|
|
7.6.1. |
The wall-mounted drinking fountain is inaccessible because it provides only 26½ inches of clear knee height. |
DF4 |
30 months |
7.6.2. |
Although a designated accessible drinking fountain is provided, there is no drinking fountain provided for people who have difficulty bending or stooping. |
DF3 |
30 months |
8. |
Butterfly Park, 3717 W. Meinecke Av. |
|
|
8.1. |
Exterior routes: |
|
|
8.1.1. |
The route from the sidewalk to the swings is inaccessible because there is a change in level where the sidewalk meets the swing play surface. |
AR1 |
30 months |
8.1.2. |
The route from the sidewalk to the playground is inaccessible because there is a change in level where the sidewalk meets the playground area surface. |
AR1 |
30 months |
9. |
Capitol Library, 3969 N. 74th St. |
|
|
9.1. |
Parking: The designated accessible parking is inaccessible because the access aisle slopes 2.7%. |
P4 |
30 months |
9.2. |
Exterior ramp between parking lot and entrance: The ramp is inaccessible because it has a cross-slope of up to 4.3%. |
R4 |
30 months |
9.3. |
Exterior route between ramp and entrance: The route is inaccessible because there are cross-slopes of up to 4.1%. |
AR1 |
30 months |
9.4. |
Route from front entrance into library: The route is inaccessible because it slopes 5.3% with no ramp features. |
AR1 |
30 months |
9.5. |
Women€™s single-user toilet room: |
|
|
9.5.1. |
The toilet room sign is mounted on the door. |
TR11 |
12 months |
9.5.2. |
The door is inaccessible because it requires 10 pounds of force to open. |
D3 |
12 months |
9.5.3. |
No accessible coat hook has been provided. |
TR3 |
24 months |
9.5.4. |
The lavatory is inaccessible because the hot water and drain pipes are not insulated or otherwise configured to protect against contact. |
LS2 |
24 months |
9.5.5. |
The toilet is inaccessible because the top of the seat is 16 inches high. |
TR9 |
30 months |
9.5.6.
|
The toilet is inaccessible because the rear grab bar is mounted with its closer end 12 inches from the side wall. |
TR14 |
24 months |
9.6. |
Men€™s single-user toilet room: |
|
|
9.6.1. |
The toilet room sign is mounted on the door. |
TR11 |
12 months |
9.6.2. |
The door is inaccessible because it requires 7 pounds of force to open. |
D3 |
12 months |
9.6.3. |
No accessible mirror has been provided. |
TR5 |
24 months |
9.6.4. |
The lavatory is inaccessible because the hot water and drain pipes are not insulated or otherwise configured to protect against contact. |
LS2 |
24 months |
9.6.5. |
The toilet is inaccessible because the top of the seat is 15 inches high. |
TR9 |
30 months |
9.6.6. |
The toilet is inaccessible because the flush control is on the closed side. |
TR4 |
30 months |
9.6.7.
|
The toilet is inaccessible because the rear grab bar is mounted with its closer end 8 inches from the side wall. |
TR14 |
24 months |
10. |
Cass Playground, 1620 N. Cass St. |
|
|
10.1. |
Exterior route: The route to the tennis courts is inaccessible because it is not firm, stable, or slip-resistant. |
AR1 |
30 months |
10.2. |
Picnic tables: The picnic tables are inaccessible because none provide the required knee space. |
DW1 |
30 months |
11. |
Central Library, 814 W. Wisconsin Av. |
|
|
11.1. |
Exterior entrances: Although the building has directional signage posted at inaccessible entrances, it does not have the International Symbol of Accessibility posted at the accessible entrance. |
D10 |
12 months |
11.2. |
Interior ramp near 8th Street entrance: The ramp is inaccessible because the handrails do not have 12 inch extensions at the bottom of the ramp. |
R2 |
24 months |
11.3. |
Ground level drinking fountain: |
|
|
11.3.1. |
The drinking fountain is inaccessible because it provides only 24¾ inches of clear knee height. |
DF4 |
30 months |
11.3.2. |
Although two lower fountains are provided, there is no drinking fountain provided for people who have difficulty bending or stooping. |
DF3 |
30 months |
11.4. |
1st floor meeting room: The meeting room is inaccessible to people with hearing disabilities because there is no assistive listening system provided. |
AA4 |
30 months |
11.5. |
1st floor men€™s toilet room with stalls near main entrance: |
|
|
11.5.1. |
No accessible mirror has been provided. |
TR5 |
24 months |
11.5.2. |
The air dryer protrudes into the walkway and is not detectable to blind persons using a cane. |
AR7 |
12 months |
11.5.3. |
The lavatory is inaccessible because the hot water and drain pipes are not insulated or otherwise configured to protect against contact. |
LS2 |
24 months |
11.5.4. |
The pull side of the door, which is accessed through a front approach, is inaccessible because it does not have at least 12 inches of clear space on the latch side. |
D5 |
30 months |
11.5.5. |
The designated accessible toilet is inaccessible because the top of the seat is 19¼ inches high. |
TR9 |
30 months |
11.5.6. |
The designated accessible toilet is inaccessible because the side grab bar is obstructed by the toilet paper dispenser. |
TR15 |
12 months |
11.5.7. |
The designated accessible toilet is inaccessible because the side grab bar is mounted with its farther end 45 inches from the rear wall. |
TR17 |
12 months |
11.6. |
1st floor women€™s toilet room with stalls near main entrance: |
|
|
11.6.1. |
No accessible mirror has been provided. |
TR5 |
24 months |
11.6.2. |
The air dryer protrudes into the walkway and is not detectable to blind persons using a cane. |
AR7 |
12 months |
11.6.3. |
The sanitary napkin dispenser protrudes into the walkway and is not detectable to blind persons using a cane. |
AR7 |
12 months |
11.6.4. |
The sanitary napkin dispenser is inaccessible because the controls require twisting of the wrist to operate. |
CT2 |
24 months |
11.6.5. |
No accessible coat hook has been provided. |
TR3 |
24 months |
11.6.6. |
The pull side of the door, which is accessed through a front approach, is inaccessible because it does not have at least 12 inches of clear space on the latch side. |
D5 |
30 months |
11.6.7. |
The designated accessible toilet is inaccessible because the side grab bar is mounted with its farther end 44 inches from the rear wall. |
TR17 |
12 months |
11.7. |
1st floor drinking fountain between toilets near main entrance: |
|
|
11.7.1. |
The wall-mounted drinking fountain is inaccessible because it provides only 26½ inches of clear knee height. |
DF4 |
30 months |
11.7.2. |
The higher drinking fountain protrudes into the walkway and is not detectable to blind persons using a cane. |
AR7 |
12 months |
11.8. |
1st floor children / caretakers€™ men€™s toilet room with stalls near children€™s area: |
|
|
11.8.1. |
The toilet room sign is not accessible. |
TR11 |
12 months |
11.8.2. |
The air dryer protrudes into the walkway and is not detectable to blind persons using a cane. |
AR7 |
12 months |
11.9. |
1st floor children / caretakers€™ women€™s toilet room with stalls near children€™s area: |
|
|
11.9.1. |
The toilet room sign is not accessible. |
TR11 |
12 months |
11.9.2. |
The air dryer protrudes into the walkway and is not detectable to blind persons using a cane. |
AR7 |
12 months |
11.10. |
2nd floor women€™s toilet room with stalls in the Arts Wing: |
|
|
11.10.1. |
No accessible mirror has been provided. |
TR5 |
24 months |
11.10.2. |
The air dryer protrudes into the walkway and is not detectable to blind persons using a cane. |
AR7 |
12 months |
11.10.3. |
The sanitary napkin dispenser is inaccessible because the controls require twisting of the wrist to operate. |
CT2 |
24 months |
11.11. |
2nd floor men€™s toilet room with stalls in the Arts Wing: |
|
|
11.11.1. |
No accessible mirror has been provided. |
TR5 |
24 months |
11.11.2. |
The air dryer protrudes into the walkway and is not detectable to blind persons using a cane. |
AR7 |
12 months |
12. |
Environmental Education and Recycling Center, 1313 W. Mt. Vernon Av. |
|
|
12.1. |
Parking lot: The unmarked parking lot, with a total of approximately 16 parking spaces, is inaccessible because it has no spaces designated as accessible. This lot requires 1 van accessible space. |
P1 |
30 months |
12.2. |
Women€™s toilet room with stalls: |
|
|
12.2.1. |
The toilet room sign has no raised or Braille characters. |
TR11 |
12 months |
12.2.2. |
The door is inaccessible because knob hardware is used. |
D2 |
24 months |
12.2.3. |
Although an audible alarm is provided in this facility, there is no visual alarm appliance in the toilet room. |
AL1 |
30 months |
12.2.4. |
The route to the toilet room is inaccessible because the vestibule (with change in direction) between the two entrance doors does not provide sufficient depth. |
AR1 |
30 months |
12.2.5. |
The lavatory is inaccessible because the hot water and drain pipes are not insulated or otherwise configured to protect against contact. |
LS2 |
24 months |
12.2.6. |
No accessible coat hook has been provided. |
TR3 |
24 months |
12.2.7. |
The designated accessible stall is incorrectly configured as an ambulatory or alternate stall, and there is no standard accessible stall provided. |
TR2 |
30 months |
12.3. |
Men€™s toilet room with stalls: |
|
|
12.3.1. |
The toilet room sign is mounted on the door and has no raised or Braille characters. |
TR11 |
12 months |
12.3.2. |
The door is inaccessible because knob hardware is used. |
D2 |
24 months |
12.3.3. |
Although an audible alarm is provided in this facility, there is no visual alarm appliance in the toilet room. |
AL1 |
30 months |
12.3.4. |
The paper towel dispenser is inaccessible because it is mounted with the controls 60 inches high. |
CT4 |
12 months |
12.3.5. |
No accessible coat hook has been provided. |
TR3 |
24 months |
12.3.6. |
The pull side of the door, which is accessed through a front approach, is inaccessible because it does not have at least 18 inches of clear space on the latch side. |
D5 |
30 months |
12.3.7. |
The designated accessible stall is incorrectly configured as an ambulatory or alternate stall, and there is no standard accessible stall provided. |
TR2 |
30 months |
12.3.8. |
The bench is inaccessible because it is less than 24 inches wide and is not secured to the wall or provides back support. |
LR2 |
24 months |
12.4. |
Observatory: The lift to the Observatory is inaccessible because it has not been maintained in working order. |
M1 |
30 months |
13. |
Forest Home Library, 1432 W. Forest Home Av. |
|
|
13.1. |
Women€™s single-user toilet room: The pull side of the door, which is accessed through a front approach, is inaccessible because a drinking fountain obstructs the door€™s required maneuvering clearance. |
D5 |
30 months |
14. |
Jewell Play Field and Field House, 1801/1810 W. Wood Av. |
|
|
14.1. |
Men€™s toilet room: |
|
|
14.1.1. |
This toilet room was locked at the time of the survey. Ensure that this toilet room is fully accessible. |
TR1 |
30 months |
14.1.2. |
The entry door is inaccessible because there is a 2 inch high threshold. |
D12 |
30 months |
14.2. |
Women€™s toilet room: |
|
|
14.2.1. |
This toilet room was locked at the time of the survey. Ensure that this toilet room is fully accessible. |
TR1 |
30 months |
14.2.2. |
The toilet room is inaccessible because there is a 7 inch high step at the entry door. |
D12 |
30 months |
14.3. |
Exterior route: |
|
|
14.3.1. |
The route to the swings is inaccessible because there is a 3 inch change of level where the sidewalk meets the play surface. |
AR1 |
30 months |
14.3.2. |
The curb ramp near the ballfield bleachers is inaccessible because it has a slope of 14½%. |
AR4 |
30 months |
14.4. |
Bleachers: The bleachers are inaccessible because there are no wheelchair spaces provided. |
AA6 |
30 months |
14.5. |
Benches: There are no firm, stable, and slip-resistant spaces alongside the benches to allow a transfer. |
EB1 |
30 months |
15. |
Keenan Health Center, 3200 N. 36th St. |
|
|
15.1. |
Parking lot: The parking lot, with a total of 16 parking spaces of which one is designated as a standard accessible parking space, is inaccessible because it lacks van-accessible signage, the parking space and accompanying access aisle are not level, and the parking space is not on the shortest accessible route to the designated accessible entrance. This lot requires 1 van accessible space. |
P1 |
30 months |
15.2.
|
Exterior route: The route from the parking lot to the designated accessible entrance is inaccessible because the surface is not firm, stable, and slip-resistant. |
AR1 |
30 months |
15.3. |
Exterior designated accessible entrance: |
|
|
15.3.1. |
The building does not have the International Symbol of Accessibility posted at accessible entrances. |
D10 |
24 months |
15.3.2. |
The designated accessible exterior door is inaccessible because there is a slope of 6.8% within the door€™s required maneuvering clearance. |
D7 |
30 months |
15.3.3. |
The designated accessible entrance door is inaccessible because knob hardware is used. |
D2 |
24 months |
15.3.4. |
The pull side of the door, which is accessed through a front approach, is inaccessible because it has only 15 inches of clear space on the latch side. |
D5 |
30 months |
15.4. |
Elevator serving the designated accessible entrance: |
|
|
15.4.1. |
The elevator is inaccessible because the hall call buttons do not have visual signals on the buttons to indicate when the call is registered and answered. |
E3 |
30 months |
15.4.2. |
The elevator is inaccessible because the doors do not stay fully open a minimum of 3 seconds. |
E6 |
30 months |
15.4.3. |
The elevator is inaccessible because the emergency system requires voice communication to operate. |
E7 |
30 months |
15.5. |
Basement interior route: The route from the entrance to the Tuberculosis Clinic is inaccessible because it slopes up to 6% with no ramp features. |
AR1 |
30 months |
15.6. |
Basement - Tuberculosis Clinic: |
|
|
15.6.1. |
The clinic entrance door along the carpeted route is inaccessible because it has an opening width of 27 inches. |
D14 |
30 months |
15.6.2. |
The clinic entrance door along the carpeted route is inaccessible because it requires 10 pounds of force to open. |
D3 |
24 months |
15.7. |
Basement unisex single-user toilet room: |
|
|
15.7.1. |
The toilet room sign is mounted on the door and has no raised or Braille characters. |
TR11 |
24 months |
15.7.2. |
No accessible coat hook has been provided. |
TR3 |
24 months |
15.7.3. |
The soap dispenser is inaccessible because it is mounted with the controls 50 inches high, and requires a forward reach. |
CT4 |
24 months |
15.7.4. |
The toilet is inaccessible because the top of the seat is 15½ inches high. |
TR9 |
30 months |
15.7.5. |
The toilet paper dispenser is inaccessible because it is mounted on the rear wall. |
TR6 |
24 months |
15.7.6. |
The toilet is inaccessible because the flush control is on the closed side. |
TR4 |
30 months |
15.7.7. |
The toilet is inaccessible because there are no grab bars provided. |
TR18 |
24 months |
15.8. |
Doors throughout facility: Numerous interior doors are inaccessible because knob hardware is used. |
D2 |
30 months |
15.9. |
1st floor men€™s toilet room with stalls near the waiting room: The toilet room contains a number of inaccessible elements and is not accessible to people with disabilities. |
TR1 |
30 months |
15.10. |
1st floor women€™s toilet room with stalls near the waiting room: The toilet room contains a number of inaccessible elements and is not accessible to people with disabilities. |
TR1 |
30 months |
15.11. |
1st floor WIC waiting room: The sign-in counter is inaccessible because it is 42½ inches high. |
C1 |
24 months |
15.12. |
1st floor exam room 118: |
|
|
15.12.1. |
The entry doors are inaccessible because they have opening widths of 28½ inches each. |
D14 |
30 months |
15.12.2. |
The entry doors are inaccessible because the vestibule is not sufficiently deep. |
D4 |
30 months |
15.12.3. |
The pull side of the door, which is accessed through a front approach, is inaccessible because it has less than 18 inches of clear space on the latch side. |
D5 |
30 months |
15.12.4. |
The room number sign is inaccessible because it does not have raised and Braille characters. |
D15 |
30 months |
15.13. |
1st floor drinking fountain near Station 4: |
|
|
15.13.1. |
The drinking fountain is inaccessible because the flow of water is not within 3 inches of the front of the fountain. |
DF5 |
30 months |
15.13.2. |
The wall-mounted drinking fountain is inaccessible because it provides only 14 inches of clear knee depth. |
DF4 |
30 months |
15.13.3. |
Although a designated accessible drinking fountain is provided, there is no drinking fountain provided for people who have difficulty bending or stooping. |
DF3 |
30 months |
15.14. |
2nd floor interior route: A fire extinguisher protrudes into the walkway near the STD clinic and is not detectable to blind persons using a cane. |
AR7 |
30 months |
15.15. |
3rd floor men€™s toilet room with stalls: The toilet room contains a number of inaccessible elements and is not accessible to people with disabilities. |
TR1 |
30 months |
15.16. |
3rd floor women€™s toilet room with stalls: The toilet room contains a number of inaccessible elements and is not accessible to people with disabilities. |
TR1 |
30 months |
16. |
Long Island Play Field, 5320 N. Long Island Dr. |
|
|
16.1. |
Exterior route: |
|
|
16.1.1. |
The route from the street to the sidewalk leading to the park is inaccessible because no curb ramp is provided. |
AR4 |
30 months |
16.1.2. |
There are no firm, stable, and slip-resistant spaces alongside the benches to allow a transfer. |
EB1 |
30 months |
17. |
Marcus DeBack Play Field, 2461 N. 55th St. |
|
|
17.1. |
Exterior route: The route to the swings is inaccessible because the surface is not firm, stable, and slip-resistant. |
AR1 |
30 months |
18. |
Martin Luther King Library, 310 W. Locust St. |
|
|
18.1. |
Parking lot: |
|
|
18.1.1. |
The designated van-accessible parking is inaccessible because the access aisle is 67 inches wide. |
P6 |
30 months |
18.1.2. |
The designated accessible parking is inaccessible because the access aisle slopes 2.6%. |
P4 |
30 months |
18.2. |
Exterior route: The route from the parking to the entrance is inaccessible because the curb ramp has a slope of 9.8%, and the flared sides have slopes of up to 27.9%. |
AR4 |
30 months |
18.3. |
Meeting room: The row of coat hooks is too high. |
S1 |
12 months |
18.4. |
Drinking fountains near meeting room: The higher drinking fountain protrudes into the walkway and is not detectable to blind persons using a cane. |
AR7 |
12 months |
18.5. |
Men€™s single-user toilet room: |
|
|
18.5.1. |
The toilet room sign has no raised or Braille characters. |
TR11 |
12 months |
18.5.2. |
The door is inaccessible because it requires 7 pounds of force to open. |
D3 |
12 months |
18.5.3. |
No accessible coat hook has been provided. |
TR3 |
24 months |
18.5.4. |
No accessible mirror has been provided. |
TR5 |
24 months |
18.5.5. |
The baby changing station is inaccessible because it is mounted with the handle 57 inches high. |
DW1 |
12 months |
18.5.6. |
The toilet is inaccessible because its centerline is 19 inches from the side wall. |
TR7 |
30 months |
18.5.7. |
The toilet is inaccessible because the rear grab bar is 30 inches long. |
TR14 |
24 months |
18.6. |
Women€™s single-user toilet room: |
|
|
18.6.1. |
The toilet room sign is mounted on the door and has no raised or Braille characters. |
TR11 |
12 months |
18.6.2. |
The door is inaccessible because it requires 8 pounds of force to open. |
D3 |
12 months |
18.6.3. |
No accessible coat hook has been provided. |
TR3 |
24 months |
18.6.4. |
The sanitary napkin dispenser is inaccessible because the controls require tight grasping to operate. |
CT2 |
24 months |
18.6.5. |
The sanitary napkin dispenser is inaccessible because the coin slot is higher than 48 inches high. |
CT4 |
12 months |
18.6.6. |
The baby changing station is inaccessible because it is mounted with the handle 57 inches high. |
DW1 |
12 months |
18.6.7. |
The toilet is inaccessible because the rear grab bar is 30 inches long. |
TR14 |
24 months |
19. |
Parking Structure at 1000 N. Water St. |
|
|
19.1. |
The parking lot, with a total of 1542 parking spaces, is inaccessible because it only has 22 spaces designated as accessible. The 2nd through 8th levels each have 3 to 4 designated accessible parking spaces, but they all are not level and have signage that is mounted too low. No van-accessible parking spaces are provided. |
P1 |
30 months |
19.2. |
The elevator is inaccessible because the emergency system requires voice communication to operate. |
E7 |
30 months |
20. |
Police Administration Building, 749 W. State St. |
|
|
20.1. |
Interior doors: Interior doors throughout the entire facility are inaccessible because knob hardware is used. |
D2 |
30 months |
20.2. |
Toilet rooms on each floor (except 2nd floor): The toilet rooms on each floor (except for the 2nd floor) contain a number of inaccessible elements and are not accessible to people with disabilities. |
TR1 |
30 months |
20.3. |
6th floor Sensitive Crimes Division (room 601): The counter is inaccessible because it is 42 inches high. |
C1 |
30 months |
20.4. |
Jail cells: There is no accessible cell provided. |
PJ1 |
30 months |
20.5. |
3rd floor Identification Division (room 305): |
|
|
20.5.1. |
The counter is inaccessible because it is 40 inches high. |
C1 |
30 months |
20.5.2. |
The lavatory is inaccessible because the top of the rim or counter is 36 inches high, and it has no knee space underneath. |
LS3 |
30 months |
20.5.3. |
The paper towel dispenser is inaccessible because it is mounted with the controls 55 inches high over the lavatory. |
CT4 |
24 months |
20.5.4.
|
The soap dispenser is inaccessible because it is mounted with the controls 48 inches high over the lavatory. |
CT4 |
24 months |
20.6. |
3rd floor drinking fountain next to sink: Although a designated accessible drinking fountain is provided, there is no drinking fountain provided for people who have difficulty bending or stooping. |
DF3 |
30 months |
20.7. |
2nd floor Parking Citations (room 204-J): The counter is inaccessible because it is 42 inches high. |
C1 |
30 months |
20.8. |
2nd floor First District room: The counter is inaccessible because it is 40½ inches high. |
C1 |
30 months |
20.9. |
2nd floor City Attorney€™s Office (room 205): The counter is inaccessible because it is 43 inches high. |
C1 |
30 months |
20.10. |
2nd floor Justice 2000 Office (room 204K): The counter is inaccessible because it is 40 inches high. |
C1 |
30 months |
20.11. |
2nd floor men€™s toilet room: |
|
|
20.11.1. |
The toilet room sign has no raised or Braille characters. |
TR11 |
24 months |
20.11.2. |
The toilet seat cover dispenser is inaccessible because it is mounted 48 inches high behind the toilet. |
CT3 |
24 months |
20.11.3. |
The soap dispenser is inaccessible because it is mounted with the controls 56 inches high. |
CT4 |
24 months |
20.11.4. |
The paper towel dispenser is inaccessible because it is mounted with the controls 63 inches high. |
CT4 |
24 months |
20.11.5. |
The lavatory is inaccessible because the hot water and drain pipes are not insulated or otherwise configured to protect against contact. |
LS2 |
30 months |
20.11.6. |
The lavatory is inaccessible because it has twist-type hardware. |
LS4 |
30 months |
20.11.7. |
The designated accessible stall is incorrectly configured as an ambulatory or alternate stall, and there is no standard accessible stall provided. |
TR2 |
30 months |
20.12. |
2nd floor women€™s toilet room: |
|
|
20.12.1. |
The toilet room sign has no raised or Braille characters. |
TR11 |
24 months |
20.12.2. |
The toilet seat cover dispenser is inaccessible because it is mounted 48 inches high behind the toilet. |
CT3 |
24 months |
20.12.3. |
The soap dispenser is inaccessible because it is mounted with the controls 44½ inches high over the lavatory. |
CT3 |
24 months |
20.12.4. |
The paper towel dispenser is inaccessible because it is mounted with the controls 63 inches high. |
CT4 |
24 months |
20.12.5. |
The lavatory is inaccessible because the hot water and drain pipes are not insulated or otherwise configured to protect against contact. |
LS2 |
30 months |
20.12.6. |
The lavatory is inaccessible because it has twist-type hardware. |
LS4 |
24 months |
20.12.7. |
No accessible coat hook has been provided. |
TR3 |
24 months |
20.12.8. |
The designated accessible stall is incorrectly configured as an ambulatory or alternate stall, and there is no standard accessible stall provided. |
TR2 |
30 months |
20.13. |
1st floor police reception counter: The counter is inaccessible because it is 40 inches high. |
C1 |
30 months |
20.14. |
Branch 3 municipal courtroom: |
|
|
20.14.1. |
The witness stand is inaccessible because it can be accessed only by steps. |
AA8 |
30 months |
20.14.2. |
The courtroom is inaccessible to people with hearing disabilities because there is no assistive listening system provided. |
AA4 |
30 months |
20.14.3. |
The courtroom is inaccessible because no wheelchair seating areas are provided. |
AA6 |
30 months |
20.15. |
Elevator to street: |
|
|
20.15.1. |
The elevator is inaccessible because the hall call buttons do not have visual signals that indicate when a call is registered or answered. |
E3 |
30 months |
20.15.2. |
The elevator is inaccessible because the time from notification that a car is answering a call until the doors of that car start to close is less than 5 seconds. |
E6 |
30 months |
20.15.3. |
The elevator is inaccessible because the emergency system requires tight grasping or pinching to access. |
E7 |
30 months |
21. |
Police Safety Academy, 6680 N. Teutonia Av. |
|
|
21.1. |
Parking lot: The parking lot, with a total of 122 parking spaces, is inaccessible because the 5 designated accessible parking spaces lack access aisles. This lot requires 1 van accessible space and 4 standard accessible spaces. |
P1 |
30 months |
21.2. |
Exterior route: The route from the parking lot€™s curb ramp to the accessible rear entrance is inaccessible because there is a change in level measuring ¾ inches between the curb ramp and the sidewalk in front of the rear entrance. |
AR1 |
30 months |
21.3. |
Designated accessible entrance, vestibule: The designated accessible entrance is inaccessible because the vestibule is not sufficiently deep. |
D4 |
30 months |
21.4. |
Room signage throughout building: The signage provided is inaccessible because it does not have raised and Braille characters. |
D15 |
24 months |
21.5. |
Chapel Classroom 109: The pull side of the door, which is accessed through a front approach, is inaccessible because it has less than 18 inches of clear space on the latch side. |
D5 |
30 months |
21.6. |
Room 117: |
|
|
21.6.1. |
The door is inaccessible because knob hardware is used. |
D2 |
24 months |
21.6.2. |
The counter is inaccessible because it is 43 inches high. |
C1 |
30 months |
21.7. |
Drinking fountain by Community Services / Safety (room 151): |
|
|
21.7.1. |
The drinking fountain is inaccessible because the spout height measures 40 inches above the floor. |
DF3 |
30 months |
21.7.2. |
The drinking fountain is inaccessible because the controls require more than 5 pounds of pressure to operate. |
DF2 |
30 months |
21.7.3. |
The drinking fountain is inaccessible because it has insufficient toe and knee clearances. |
DF4 |
30 months |
21.7.4. |
The drinking fountain is inaccessible because there is not at least 30 inches maneuvering width centered on the fountain. |
DF1 |
30 months |
21.8. |
Drinking fountain by Printing and Stores (room 166): |
|
|
21.8.1. |
The drinking fountain is inaccessible because the spout height measure 40 inches above the floor. |
DF3 |
30 months |
21.8.2. |
The drinking fountain is inaccessible because the controls require more than 5 pounds of pressure to operate. |
DF2 |
30 months |
21.8.3. |
The drinking fountain is inaccessible because it has insufficient toe and knee clearances. |
DF4 |
30 months |
21.8.4. |
The drinking fountain is inaccessible because there is not at least 30 inches maneuvering width centered on the fountain. |
DF1 |
30 months |
21.9. |
Drinking fountain by men€™s toilet room (room 182): |
|
|
21.9.1. |
The drinking fountain is inaccessible because the spout height measures 40 inches above the floor. |
DF3 |
30 months |
21.9.2. |
The drinking fountain is inaccessible because the controls require more than 5 pounds of pressure to operate. |
DF2 |
30 months |
21.9.3. |
The drinking fountain is inaccessible because it has insufficient toe and knee clearances. |
DF4 |
30 months |
21.9.4. |
The drinking fountain is inaccessible because there is not at least 30 inches maneuvering width centered on the fountain. |
DF1 |
30 months |
21.10. |
Drinking fountain by Administrative (room 117): |
|
|
21.10.1. |
The drinking fountain is inaccessible because the spout height measures 40 inches above the floor. |
DF3 |
30 months |
21.10.2. |
The drinking fountain is inaccessible because the controls require more than 5 pounds of pressure to operate. |
DF2 |
30 months |
21.10.3. |
The drinking fountain is inaccessible because it has insufficient toe and knee clearances. |
DF4 |
30 months |
21.10.4. |
The drinking fountain is inaccessible because there is not at least 30 inches maneuvering width centered on the fountain. |
DF1 |
30 months |
21.11. |
Theater (Room 142): |
|
|
21.11.1. |
The pull side of the entrance door, which is accessed through a front approach, is inaccessible because it has less than 18 inches of clear space on the latch side. |
D5 |
30 months |
21.11.2. |
The door is inaccessible because knob hardware is used. |
D2 |
30 months |
21.12. |
Safety (Room 151): |
|
|
21.12.1. |
The pull side of the entrance door, which is accessed through a front approach, is inaccessible because it has less than 18 inches of clear space on the latch side. |
D5 |
30 months |
21.12.2. |
The door is inaccessible because knob hardware is used. |
D2 |
30 months |
21.13. |
Women€™s toilet room with stalls (sometimes used as men€™s toilet room): |
|
|
21.13.1. |
The toilet room sign does not have raised or Braille characters. |
TR11 |
24 months |
21.13.2. |
The door is inaccessible because it has an opening width of 30 inches. |
D14 |
30 months |
21.13.3. |
No accessible mirror has been provided. |
TR5 |
24 months |
21.13.4. |
The paper towel dispenser is inaccessible because it is mounted too high behind an obstruction. |
CT3 |
12 months |
21.13.5. |
The lavatory is inaccessible because a foot pedal is required to operate it, and it has no knee space clearance. |
LS1 |
30 months |
21.13.6. |
The urinal is inaccessible because the rim is 24 inches high and the flush control is higher than 44 inches. |
TR8 |
30 months |
21.13.7. |
There is no accessible toilet stall provided. |
TR2 |
30 months |
21.14. |
Men€™s toilet room with stalls (near classroom 182): |
|
|
21.14.1. |
The toilet room sign does not have raised or Braille characters. |
TR11 |
24 months |
21.14.2. |
The door is inaccessible because it has an opening width of 30 inches. |
D14 |
30 months |
21.14.3. |
The lavatory is inaccessible because the hot water and drain pipes are not covered or configured to protect against contact. |
LS2 |
30 months |
21.14.4. |
The lavatory is inaccessible because the lavatory hardware requires tight grasping and twisting to operate. |
LS4 |
24 months |
21.14.5. |
There is no accessible toilet stall provided. |
TR2 |
30 months |
21.15. |
Men and women€™s single-user toilet rooms (near classroom 159) (existing): These toilet rooms are inaccessible. There is no signage directing people with disabilities to the accessible toilet rooms. |
TR10 |
30 months |
21.16. |
Classroom 182: The entrance door is inaccessible because knob hardware is used. |
D2 |
24 months |
21.17. |
Elevator (near offices): |
|
|
21.17.1. |
The elevator is inaccessible because the elevator doors do not automatically re-open if obstructed nor automatically re-open without contact when the obstruction is between 5 to 29 inches above the floor. |
E6 |
30 months |
22. |
Robert Anderson Water Tower and Municipal Building, 4001 S. 6th St. |
|
|
22.1. |
Parking lot: |
|
|
22.1.1. |
The parking lot, with a total of 70 parking spaces of which 2 are designated as van-accessible and 2 as standard accessible, is inaccessible because the van-accessible parking spaces€™ access aisles are less than 96 inches wide, and one space has a slope of 4.1%. In addition, the signs are mounted too low. This lot requires at least 1 van accessible space and 2 standard accessible spaces. |
P1 |
30 months |
22.2. |
Lobby elevator: The elevator is inaccessible because the hall lanterns do not emit a visual nor audible signal indicating when a car is answering a call. In addition, the hall lanterns do not signal once for up, twice for down (or have voice equivalent). |
E10 |
30 months |
22.3. |
1st floor hallway: The white metallic AED cabinet next to the directory protrudes into the walkway and is not detectable to blind persons using a cane. |
AR7 |
12 months |
22.4. |
1st floor employees area women€™s toilet room with stalls: |
|
|
22.4.1. |
The door is inaccessible because it requires 10 pounds of force to open. |
D3 |
12 months |
22.4.2. |
The designated accessible toilet is inaccessible because the side grab bar is mounted with its farther end 47 inches from the rear wall. |
TR17 |
12 months |
22.5. |
1st floor employees area men€™s toilet room with stalls: |
|
|
22.5.1. |
The door is inaccessible because it requires 10 pounds of force to open. |
D3 |
12 months |
22.5.2. |
The designated accessible toilet is inaccessible because the side grab bar is mounted with its farther end 47 inches from the rear wall. |
TR17 |
12 months |
22.6. |
2nd floor employees area women€™s toilet room with stalls: |
|
|
22.6.1. |
The designated accessible toilet is inaccessible because the side grab bar is mounted with its farther end 47 inches from the rear wall. |
TR17 |
12 months |
22.7. |
2nd floor employees area men€™s toilet room with stalls: |
|
|
22.7.1. |
The designated accessible toilet is inaccessible because the side grab bar is mounted with its farther end 47 inches from the rear wall. |
TR17 |
12 months |
22.8. |
3rd Floor Kitchenette: |
|
|
22.8.1. |
The microwave oven€™s controls are inaccessible because they are mounted more than 48 inches high over an obstruction. |
CT3 |
24 months |
22.8.2. |
The sink is inaccessible because it lacks required knee and toe space. |
LS3 |
30 months |
22.9. |
3rd floor drinking fountain in community area near toilet rooms: Although a designated accessible drinking fountain is provided, there is no drinking fountain provided for people who have difficulty bending or stooping. |
DF3 |
30 months |
22.10. |
3rd floor women€™s toilet room with stalls: |
|
|
22.10.1. |
The toilet room door is inaccessible because it requires 10 pounds of force to open. |
D3 |
12 months |
22.10.2. |
The designated accessible toilet is inaccessible because the side grab bar is mounted with its farther end 48 inches from the rear wall. |
TR17 |
12 months |
22.10.3. |
The toilet seat cover dispenser is inaccessible because it is mounted above reach ranges beside the toilet. |
CT3 |
12 months |
22.11. |
3rd floor men€™s toilet room with stalls: |
|
|
22.11.1. |
The toilet room door is inaccessible because it requires 10 pounds of force to open. |
D3 |
12 months |
22.11.2. |
The designated accessible toilet is inaccessible because the side grab bar is mounted with its farther end 48 inches from the rear wall. |
TR17 |
12 months |
22.11.3. |
The toilet seat cover dispenser is inaccessible because it is mounted above reach ranges beside the toilet. |
CT3 |
12 months |
23. |
Tow Lot Office, 3811 W. Lincoln Av. |
|
|
23.1. |
Parking lot: |
|
|
23.1.1. |
The parking lot, with a total of 32 parking spaces of which 1 is designated as van-accessible and 1 as standard accessible, is inaccessible because the van-accessible parking space€™s access aisle is 94 inches wide. This lot requires at least 1 van accessible space and 1 standard accessible space. |
P1 |
30 months |
23.2. |
Lobby area unisex single-user toilet room: |
|
|
23.2.1. |
The toilet room sign is mounted on the door. |
TR11 |
12 months |
23.2.2. |
The toilet is inaccessible because the flush control is on the closed side. |
TR4 |
30 months |
23.3. |
Drinking fountain by lobby area toilet room: Although a designated accessible drinking fountain is provided, there is no drinking fountain provided for people who have difficulty bending or stooping. |
DF3 |
30 months |
24. |
Zablocki Library, 3501 W. Oklahoma Av. |
|
|
24.1.
|
Exterior route from parking lot access aisle to sidewalk: The route is inaccessible because there is a 1 inch change in level where the access aisle meets the sidewalk. |
AR1 |
30 months |
24.2. |
Men€™s single-user toilet room: |
|
|
24.2.1. |
The door is inaccessible because it requires 12 pounds of force to open. |
D3 |
12 months |
24.2.2. |
The keyed lock on the entry door is inaccessible because the controls require twisting of the wrist to operate. |
D2 |
24 months |
24.2.3. |
No accessible mirror has been provided. |
TR5 |
24 months |
24.2.4. |
The lavatory is inaccessible because the hot water and drain pipes are not insulated or otherwise configured to protect against contact. |
LS2 |
24 months |
24.2.5. |
The toilet is inaccessible because its centerline is 19 inches from the side wall. |
TR7 |
30 months |
24.2.6. |
The toilet is inaccessible because the flush control is on the closed side. |
TR4 |
30 months |
24.2.7. |
The toilet paper dispenser is inaccessible because it is mounted 42 inches from the rear wall. |
TR6 |
12 months |
24.2.8. |
The toilet is inaccessible because the side grab bar is mounted with its farthest side 47 inches from the rear wall. |
TR17 |
12 months |
24.3. |
Women€™s single-user toilet room: |
|
|
24.3.1. |
The door is inaccessible because it requires 10 pounds of force to open. |
D3 |
12 months |
24.3.2. |
The keyed lock on the entry door is inaccessible because the controls require twisting of the wrist to operate. |
D2 |
24 months |
24.3.3. |
No accessible mirror has been provided. |
TR5 |
24 months |
24.3.4. |
The lavatory is inaccessible because the hot water and drain pipes are not insulated or otherwise configured to protect against contact. |
LS2 |
24 months |
24.3.5. |
The toilet is inaccessible because its centerline is 21 inches from the side wall. |
TR7 |
30 months |
24.3.6. |
The toilet is inaccessible because the side grab bar is mounted with its farthest side 47 inches from the rear wall. |
TR17 |
12 months |
25. |
Zeidler Municipal Building, 841 N. Broadway |
|
|
25.1. |
Basement interior route: The defibrillator near the elevator protrudes into the walkway and is not detectable to blind persons using a cane. |
AR7 |
12 months |
25.2. |
Basement men and women€™s locker rooms (existing): The locker rooms contain a number of inaccessible elements and are not accessible to people with disabilities. |
LR1 |
12 months |
25.3. |
Basement - Mail room / print shop (B-2): |
|
|
25.3.1. |
The door is inaccessible because it requires 12 pounds of force to open. |
D3 |
12 months |
25.3.2. |
The door is inaccessible because knob hardware is used. |
D2 |
24 months |
25.3.3. |
The shelf mounted on a door protrudes into the walkway and is not detectable to blind persons using a cane. |
AR7 |
12 months |
25.4. |
Basement drinking fountain (hallway): Although a designated accessible drinking fountain is provided, there is no drinking fountain provided for people who have difficulty bending or stooping. |
DF3 |
30 months |
25.5. |
Basement men and women€™s toilet rooms with stalls (existing): There is no signage directing people with disabilities to the accessible toilet rooms. |
TR10 |
24 months |
25.6. |
Lower Parking level women€™s toilet room with stalls: |
|
|
25.6.1. |
The toilet room sign has no raised or Braille characters. |
TR11 |
24 months |
25.6.2. |
The door is inaccessible because it has an opening width of 31 inches. |
D14 |
30 months |
25.6.3. |
The door is inaccessible because it requires 13 pounds of force to open. |
D3 |
13 months |
25.6.4. |
The air dryer protrudes into the walkway and is not detectable to blind persons using a cane. |
AR7 |
12 months |
25.6.5. |
The sanitary napkin dispenser is inaccessible because the controls require twisting of the wrist to operate. |
CT2 |
24 months |
25.6.6. |
The designated accessible toilet is inaccessible because its centerline is 19 inches from the side wall. |
TR7 |
30 months |
25.6.7. |
No accessible coat hook has been provided. |
TR3 |
24 months |
25.6.8. |
The designated accessible toilet is inaccessible because the side grab bar is obstructed by the toilet paper dispenser. |
TR15 |
12 months |
25.6.9. |
The designated accessible toilet is inaccessible because the side grab bar is mounted with its farther end 48 inches from the rear wall. |
TR17 |
12 months |
25.6.10.
|
The designated accessible toilet is inaccessible because the rear grab bar is obstructed by the flush pipe. |
TR15 |
30 months |
25.7. |
Lower Parking level men€™s toilet room with stalls: |
|
|
25.7.1. |
The toilet room sign is mounted on the door with its centerline at 64 inches above the floor, and has no raised or Braille characters. |
TR11 |
24 months |
25.7.2. |
The towel dispenser protrudes into the walkway and is not detectable to blind persons using a cane. |
AR7 |
12 months |
25.7.3. |
The designated accessible toilet is inaccessible because the top of the seat is 19½ inches high. |
TR9 |
30 months |
25.7.4. |
The designated accessible toilet is inaccessible because the side grab bar is obstructed by the toilet paper dispenser. |
TR15 |
12 months |
25.7.5.
|
The designated accessible toilet is inaccessible because the rear grab bar is obstructed by the flush pipe. |
TR15 |
30 months |
25.8. |
Lower Parking level drinking fountain: |
|
|
25.8.1. |
The drinking fountain is inaccessible because the flow of water is 1 inch high. |
DF5 |
30 months |
25.8.2. |
Although a designated accessible drinking fountain is provided, there is no drinking fountain provided for people who have difficulty bending or stooping. |
DF3 |
30 months |
25.9. |
1st floor men€™s toilet room with stalls: |
|
|
25.9.1. |
The air dryer protrudes into the walkway and is not detectable to blind persons using a cane. |
AR7 |
12 months |
25.9.2. |
The designated accessible toilet is inaccessible because the side grab bar is obstructed by the toilet paper dispenser. |
TR15 |
12 months |
25.10. |
1st floor women€™s toilet room with stalls: |
|
|
25.10.1. |
The sanitary napkin dispenser is inaccessible because the controls require twisting of the wrist to operate. |
CT2 |
24 months |
25.10.2. |
The designated accessible toilet is inaccessible because the side grab bar is obstructed by the toilet paper dispenser. |
TR15 |
12 months |
25.10.3. |
The toilet seat cover dispenser is inaccessible because it is mounted with the controls higher than 48 inches behind the toilet. |
CT3 |
12 months |
25.11. |
1st floor conference room (room 102): |
|
|
25.11.1. |
The conference room is inaccessible to people with hearing disabilities because there is no assistive listening system provided. |
AA4 |
30 months |
25.12. |
2nd floor men€™s toilet room with stalls: |
|
|
25.12.1. |
The pull side of the door, which is accessed through a front approach, is inaccessible because it has inadequate clear space on the latch side. |
D5 |
30 months |
25.12.2. |
The shelf under the mirror protrudes into the walkway and is not detectable to blind persons using a cane. |
AR7 |
12 months |
25.13. |
2nd floor women€™s toilet room with stalls: |
|
|
25.13.1. |
The interior vestibule door is inaccessible because it requires 15 pounds of force to open. |
D3 |
12 months |
25.13.2. |
The sanitary napkin dispenser is inaccessible because the controls require twisting of the wrist to operate. |
CT2 |
24 months |
25.13.3. |
The designated accessible toilet is inaccessible because the top of the seat is 20 inches high. |
TR9 |
30 months |
25.14. |
3rd floor men€™s toilet room with stalls: |
|
|
25.14.1. |
The paper towel dispenser is inaccessible because it is mounted with the controls higher than 48 inches over the lavatory. |
CT3 |
12 months |
25.14.2. |
The air dryer protrudes into the walkway and is not detectable to blind persons using a cane. |
AR7 |
12 months |
25.14.3. |
The designated accessible toilet is inaccessible because the top of the seat is 16½ inches high. |
TR9 |
30 months |
25.14.4. |
The designated accessible toilet is inaccessible because the flush control is on the closed side. |
TR4 |
30 months |
25.14.5. |
The designated accessible toilet is inaccessible because the side grab bar is mounted with its farther end 48 inches from the rear wall. |
TR17 |
12 months |
25.15. |
3rd floor women€™s toilet room with stalls: |
|
|
25.15.1. |
The sanitary napkin dispenser is inaccessible because the controls require twisting of the wrist to operate. |
CT2 |
24 months |
25.15.2. |
The designated accessible toilet is inaccessible because the side grab bar is mounted with its farther end 48 inches from the rear wall. |
TR17 |
12 months |
25.16. |
3rd floor drinking fountains: Although two designated accessible drinking fountains are provided, there is no drinking fountain provided for people who have difficulty bending or stooping. |
DF3 |
30 months |
25.17. |
4th floor interior route: The defibrillator protrudes into the walkway and is not detectable to blind persons using a cane. |
AR7 |
12 months |
25.18. |
4th floor drinking fountains: Although two designated accessible drinking fountains are provided, there is no drinking fountain provided for people who have difficulty bending or stooping. |
DF3 |
12 months |
25.19. |
4th floor men€™s toilet room with stalls: |
|
|
25.19.1. |
The toilet room sign does not have the International Symbol of Access. |
TR11 |
24 months |
25.19.2. |
The pull side of the toilet room door, which is accessed through a front approach, is inaccessible because it has less than 18 inches of clear space on the latch side. |
D5 |
30 months |
25.19.3. |
No accessible mirror has been provided. |
TR5 |
24 months |
25.19.4. |
The air dryer protrudes into the walkway and is not detectable to blind persons using a cane. |
AR7 |
12 months |
25.19.5. |
The paper towel dispenser is inaccessible because it is mounted with the controls higher than 48 inches over the lavatory. |
CT3 |
12 months |
25.19.6. |
The lavatory is inaccessible because the hot water and drain pipes are not insulated or otherwise configured to protect against contact. |
LS2 |
24 months |
25.19.7. |
There is no accessible toilet stall provided. |
TR2 |
12 months |
25.20. |
4th floor women€™s toilet room with stalls: |
|
|
25.20.1. |
The toilet room sign does not have the International Symbol of Access. |
TR11 |
24 months |
25.20.2. |
The pull side of the door, which is accessed through a front approach, is inaccessible because it has less than 18 inches of clear space on the latch side. |
D5 |
30 months |
25.20.3. |
The sanitary napkin dispenser is inaccessible because the controls require twisting of the wrist to operate. |
CT2 |
24 months |
25.20.4. |
The air dryer protrudes into the walkway and is not detectable to blind persons using a cane. |
AR7 |
12 months |
25.20.5. |
The paper towel dispenser is inaccessible because it is mounted with the controls higher than 48 inches and is mounted over the lavatory. |
CT3 |
12 months |
25.20.6. |
The lavatory is inaccessible because the hot water and drain pipes are not insulated or otherwise configured to protect against contact. |
LS2 |
24 months |
25.20.7. |
There is no accessible toilet stall provided. |
TR2 |
12 months |
25.21. |
4th floor Water Engineering counter: The Water Engineering counter is inaccessible because it is more than 36 inches high. |
C1 |
30 months |
25.22. |
5th floor interior route: The defibrillator protrudes into the walkway and is not detectable to blind persons using a cane. |
AR7 |
12 months |
25.23. |
5th floor men€™s toilet room with stalls: |
|
|
25.23.1. |
The air dryer protrudes into the walkway and is not detectable to blind persons using a cane. |
AR7 |
12 months |
25.23.2. |
The designated accessible toilet is inaccessible because the flush control is on the closed side. |
TR4 |
30 months |
25.23.3. |
The toilet seat cover dispenser is inaccessible because it is mounted above reach ranges behind the toilet. |
CT3 |
12 months |
25.24. |
5th floor women€™s toilet room with stalls: |
|
|
25.24.1. |
The sanitary napkin dispenser is inaccessible because the controls require twisting of the wrist to operate. |
CT2 |
24 months |
25.24.2. |
The toilet seat cover dispenser is inaccessible because it is mounted above reach ranges behind the toilet. |
CT3 |
12 months |
25.24.3. |
The designated accessible toilet is inaccessible because the flush control is on the closed side. |
TR4 |
30 months |
25.24.4. |
The designated accessible toilet is inaccessible because the side grab bar is obstructed by the toilet paper dispenser. |
TR15 |
12 months |
25.25. |
5th floor drinking fountains: Although two designated accessible drinking fountains are provided, there is no drinking fountain provided for people who have difficulty bending or stooping. |
DF3 |
30 months |
25.26. |
6th floor men€™s toilet room with stalls: |
|
|
25.26.1. |
The paper towel dispenser is inaccessible because it is mounted with the controls higher than 48 inches over the lavatory. |
CT3 |
12 months |
25.26.2. |
The air dryer protrudes into the walkway and is not detectable to blind persons using a cane. |
AR7 |
12 months |
25.26.3. |
The designated accessible toilet is inaccessible because the flush control is on the closed side. |
TR4 |
30 months |
25.26.4. |
The designated accessible toilet is inaccessible because the side grab bar is obstructed by the toilet paper dispenser. |
TR15 |
12 months |
25.27. |
6th floor women€™s toilet room with stalls: |
|
|
25.27.1. |
The sanitary napkin dispenser is inaccessible because the controls require twisting of the wrist to operate. |
CT2 |
24 months |
25.27.2. |
The paper towel dispenser is inaccessible because it is mounted with the controls higher than 48 inches over the lavatory. |
CT3 |
12 months |
25.27.3. |
The toilet seat cover dispenser is inaccessible because it is mounted with the controls higher than 48 inches behind the toilet. |
CT3 |
12 months |
25.27.4. |
The designated accessible toilet is inaccessible because the flush control is on the closed side. |
TR4 |
30 months |
25.27.5. |
The designated accessible toilet is inaccessible because the side grab bar is obstructed by the toilet paper dispenser. |
TR15 |
12 months |
25.28. |
6th floor drinking fountain: |
|
|
25.28.1. |
Although two designated accessible drinking fountains are provided, there is no drinking fountain provided for people who have difficulty bending or stooping. |
DF3 |
30 months |
25.28.2. |
The drinking fountains protrude into the walkway and are not detectable to blind persons using a cane. |
AR7 |
12 months |
25.29. |
7th floor interior route: The defibrillator protrudes into the walkway and is not detectable to blind persons using a cane. |
AR7 |
12 months |
25.30. |
7th floor drinking fountains: Although two designated accessible drinking fountains are provided, there is no drinking fountain provided for people who have difficulty bending or stooping. |
DF3 |
30 months |
25.31. |
7th floor women€™s toilet room with stalls: |
|
|
25.31.1. |
The paper towel dispenser is inaccessible because it is mounted with the controls higher than 48 inches over the lavatory. |
CT3 |
12 months |
25.31.2. |
The sanitary napkin dispenser is inaccessible because the controls require twisting of the wrist to operate. |
CT2 |
24 months |
25.31.3. |
The toilet seat cover dispenser is inaccessible because it is mounted above 48 inches high behind the toilet. |
CT3 |
12 months |
25.31.4. |
The designated accessible toilet is inaccessible because the top of the seat is 16½ inches high. |
TR9 |
30 months |
25.31.5. |
The designated accessible toilet is inaccessible because the flush control is on the closed side. |
TR4 |
30 months |
25.31.6. |
The designated accessible toilet is inaccessible because the side grab bar is obstructed by the toilet paper dispenser. |
TR15 |
12 months |
25.32. |
7th floor men€™s toilet room with stalls: |
|
|
25.32.1. |
The paper towel dispenser is inaccessible because it is mounted with the controls higher than 48 inches over the lavatory. |
CT3 |
12 months |
25.32.2. |
The designated accessible toilet is inaccessible because the top of the seat is 15½ inches high. |
TR9 |
30 months |
25.32.3. |
The designated accessible toilet is inaccessible because the flush control is on the closed side. |
TR4 |
30 months |
25.32.4. |
The designated accessible toilet is inaccessible because the side grab bar is obstructed by the toilet paper dispenser. |
TR15 |
12 months |
25.33. |
8th floor women€™s toilet room with stalls: |
|
|
25.33.1. |
The sanitary napkin dispenser is inaccessible because the controls require twisting of the wrist to operate. |
CT2 |
24 months |
25.33.2. |
The paper towel dispenser is inaccessible because it is mounted with the controls higher than 48 inches over the lavatory. |
CT3 |
12 months |
25.33.3. |
The toilet seat cover dispenser is inaccessible because it is mounted with the controls higher than 48 inches behind the toilet. |
CT3 |
12 months |
25.33.4. |
The designated accessible toilet is inaccessible because the top of the seat is 16 inches high. |
TR9 |
30 months |
25.33.5. |
The designated accessible toilet is inaccessible because the flush control is on the closed side. |
TR4 |
30 months |
25.34. |
8th floor men€™s toilet room with stalls: |
|
|
25.34.1. |
The paper towel dispenser is inaccessible because it is mounted with the controls higher than 48 inches over the lavatory. |
CT3 |
12 months |
25.34.2. |
The designated accessible toilet is inaccessible because the flush control is on the closed side. |
TR4 |
30 months |
25.34.3. |
The designated accessible toilet is inaccessible because the side grab bar is obstructed by the toilet paper dispenser. |
TR15 |
12 months |
25.34.4. |
The designated accessible toilet is inaccessible because the side grab bar is mounted 50 inches from the rear wall. |
TR17 |
12 months |
25.35. |
8th floor Map Sales office: The counter is inaccessible because it is 42¾ inches high. |
C1 |
30 months |
25.36. |
9th floor interior route: The defibrillator protrudes into the walkway and is not detectable to blind persons using a cane. |
AR7 |
12 months |
25.37. |
9th floor women€™s toilet room with stalls: |
|
|
25.37.1. |
The paper towel dispenser (nearest the lavatory that has pipe protection) is inaccessible because it is mounted with the controls higher than 48 inches over the lavatory. |
CT3 |
12 months |
25.37.2. |
The sanitary napkin dispenser is inaccessible because the controls require twisting of the wrist to operate. |
CT2 |
24 months |
25.37.3. |
The designated accessible toilet is inaccessible because the flush control is on the closed side. |
TR4 |
30 months |
25.37.4. |
No accessible coat hook has been provided. |
TR3 |
24 months |
25.38. |
9th floor men€™s toilet room with stalls: |
|
|
25.38.1. |
The pull side of the door, which is accessed through a front approach, is inaccessible because it has less than 18 inches of clear space on the latch side. |
D5 |
30 months |
25.38.2. |
The paper towel dispenser is inaccessible because it is mounted with the controls higher than 48 inches over the lavatory. |
CT3 |
12 months |
25.38.3. |
The lavatory is inaccessible because the hot water and drain pipes are not insulated or otherwise configured to protect against contact. |
LS2 |
24 months |
25.38.4. |
The designated accessible toilet is inaccessible because the top of the seat is 16½ inches high. |
TR9 |
30 months |
25.38.5. |
The designated accessible toilet is inaccessible because the flush control is on the closed side. |
TR4 |
30 months |
25.38.6. |
No accessible coat hook has been provided. |
TR3 |
24 months |
25.38.7. |
The designated accessible toilet is inaccessible because the side grab bar is obstructed by the toilet paper dispenser. |
TR15 |
12 months |
25.39. |
9th floor Planning and Development / Permits office: The counter is inaccessible because it is 42 ¼ inches high. |
C1 |
30 months |
25.40. |
9th floor Special Assessment / Estimating office: The counter is inaccessible because it is 42¼ inches high. |
C1 |
30 months |
25.41. |
10th floor interior route: The defibrillator protrudes into the walkway and is not detectable to blind persons using a cane. |
AR7 |
12 months |
25.42. |
10th floor men€™s toilet room with stalls: |
|
|
25.42.1. |
The toilet room sign is mounted above the door. |
TR11 |
12 months |
25.42.2. |
The air dryer protrudes into the walkway and is not detectable to blind persons using a cane. |
AR7 |
12 months |
25.42.3. |
The toilet seat cover dispenser is inaccessible because it is mounted more than 48 inches high behind the toilet. |
CT3 |
12 months |
25.43. |
10th floor women€™s toilet room with stalls: |
|
|
25.43.1. |
The sanitary napkin dispenser is inaccessible because the controls require twisting of the wrist to operate. |
CT2 |
24 months |
25.43.2. |
The toilet seat cover dispenser is inaccessible because it is mounted more than 48 inches high behind the toilet. |
CT3 |
12 months |
25.44. |
10th floor drinking fountains: |
|
|
25.44.1. |
The drinking fountain is inaccessible because the controls require tight grasping and twisting to operate, and the controls also require more than 5 pounds of pressure to operate. |
DF2 |
24 months |
25.44.2. |
Although a designated accessible drinking fountain is provided, there is no drinking fountain provided for people who have difficulty bending or stooping. |
DF3 |
30 months |
25.44.3. |
The drinking fountains protrude into the walkway and are not detectable to blind persons using a cane. |
AR7 |
12 months |
25.44.4. |
10th floor Dept of Neighborhood Services office: The counter is inaccessible because it is 42¼ inches high. |
C1 |
30 months |