24 |
Trefethen
Aquatic Center |
Pool
Building |
Men's
and Women's Locker Room Designated Accessible Stall |
Designated
Accessible Toilet Stall |
The
toilet centerline is 20 inches from the side wall. The toilet centerline is
required to be exactly 18 inches from the side wall. |
TAC7
and TAC8 |
4.1.3(11),
4.23.4, 4.17.3 and Fig. 30(a-1) |
The
centerline of the toilet shall be 16 inches minimum to 18 inches maximum from
the side wall or partition. |
213.3.2
and 604.2 |
|
|
35 |
Natural
Science Building |
Exterior |
Route
from Sidewalk to Entrance Walkway (Addition) |
Walkway
(Addition) |
The
slope of the walkway varies between 1:16 and 1:20, and no handrails are
provided along the portions of the walkway where the slope exceeds 1:20.
Handrails are required on both sides of each walkway segment that has a slope
greater than 1:20. |
NSB1 |
4.1.5,
4.1.2(1), 4.3.7 and 4.8.5 |
|
|
|
|
123 |
Haas
Pavilion |
First
Floor |
Gymnasium |
Bleachers |
The
side bleachers have 214 fixed seats, and the two end bleachers have an
approximate capacity of 240 fixed seats each. Four designated wheelchair
locations are provided. Eight wheelchair locations dispersed throughout the
side and end bleachers are required. |
HP4
through HP6 |
4.1.3(19)(a),
4.33.2, 4.33.3 and 4.33.4 |
|
|
|
|
124 |
Haas
Pavilion |
First
Floor |
Gymnasium |
Bleachers |
No
seats with movable armrests are provided. Seven aisle seats with no armrests
on the aisle side, or removable or folding armrests on the aisle side are
required. |
HP7 |
4.1.3(19)(a) |
At
least 5 percent of the total number of aisle seats provided shall have
folding or retractable armrests on the aisle side. |
221.4
and 802.4 |
|
|
125 |
Haas
Pavilion |
First
Floor |
Gymnasium |
Bleachers |
The
four designated wheelchair locations are located on the floor and are not a
part of the fixed seating plan. Wheelchair locations are required to be an
integral part of the fixed seating plan. |
HP8
through HP10 |
4.1.3(19)(a)
and 4.33.3 |
|
|
|
|
126 |
Haas
Pavilion |
First
Floor |
Gymnasium |
Bleachers |
A
companion seat is not provided adjacent to the two end designated wheelchair
locations. At least one fixed companion seat shall be provided adjacent to
each wheelchair location. |
HP8
and HP10 |
4.1.3(19)(a)
and 4.33.3 |
Companion
seats shall be equivalent in size, quality, comfort and amenities to the
seating in the immediate area. Companion seats are permitted to be moveable. |
221.2.1,
221.3 and 802.3 |
|
|
127 |
Haas
Pavilion |
First
Floor |
Gymnasium |
Bleachers |
The
companion seat adjacent to the two middle designated wheelchair locations is
not provided at the same finish floor elevation as the wheelchair
locations. |
HP9 |
4.1.3(19)(a)
and 4.33.3 |
|
|
|
|
207 |
Music
Building |
First
Floor |
Center
for Contemporary Music (CCM) and Ensemble Room |
Route |
An
accessible route to the first and second floor of the Center for Contemporary
Music and Ensemble Room is not provided. An accessible route is
required. |
MB2
and MB3 |
4.1.3(1)
and 4.3 |
|
|
|
|
236 |
Aaron
Art Center |
Exterior |
Parking
Lot C-1 |
Van Space |
No
van accessible parking space is provided. One van-accessible parking space
with a 96-inch wide access aisle identified by an additional "van accessible"
sign mounted below the symbol of accessibility is required. |
AC1
and AC2 |
4.1.2(5)(a)(b),
4.6.3, 4.6.4 and 4.30.7(1) |
|
|
|
|
237 |
Aaron
Art Center |
Exterior |
Parking
Lot C-1 |
Access Aisle |
The
designated accessible parking space located on the southeast side of
Kapiolani Road has a 39-inch wide access aisle. A demarcated access aisle
that is either a minimum of 60 inches wide for an accessible parking spaces
or a minimum of 96 inches wide for a van accessible space is required. |
AC1 |
4.1.2(5)(a)(b),
4.6.3 and Fig. 9 |
|
|
|
|
238 |
Aaron
Art Center |
Exterior |
Parking
Lot C-1 |
Slope |
The
surface slopes of the designated accessible parking spaces and access aisles
vary between 1:20 and 1:38. Accessible parking spaces and access aisles are
required to be level with surface slopes not exceeding 1:50 (2%) in all
directions |
AC1
and AC2 |
4.1.2(5)(a)(b)
and 4.6.3 |
|
|
|
|
239 |
Aaron
Art Center |
Exterior |
Parking
Lot C-1 |
Slope |
The
slope of the route from the accessible parking space located on the southeast
side of Kapiolani Road to the sidewalk is approximately 1:5. The maximum
allowable slope of an accessible route is 1:20. |
AC1
and AC3 |
4.1.2(1)
and 4.3.7 |
|
|
|
|
241 |
Aaron
Art Center |
Exterior |
Curb
Ramp in front of Olney Hall |
Slope |
The
slope of the side flare is approximately 1:7. The maximum allowable side
flare slope is 1:12 when a landing is not provided at the top of the curb
ramp. |
AC4 |
4.1.2(1),
4.3.7, 4.7.5 and Fig. 12 |
|
|
|
|
243 |
Aaron
Art Center |
Exterior |
Curb
Ramp in front of Aaron Art Center |
Slope |
The
slope of the curb ramp is approximately 1:7. The maximum allowable ramp slope
is 1:12. |
AC5 |
4.1.2(1),
4.3.7, 4.7.2 and 4.8.2 |
|
|
|
|
244 |
Aaron
Art Center |
Exterior |
Curb
Ramp in front of Aaron Art Center |
Slope |
The
slope of the side flare is approximately 1:8. The maximum allowable side
flare slope is 1:10. |
AC5 |
4.1.2(1),
4.3.7, 4.7.5 and Fig. 12 |
|
|
|
|
246 |
Aaron
Art Center |
Exterior |
Parking
Lot C-2 |
Parking Space |
No
"van accessible" sign is provided. One van accessible parking space with a
96-inch wide access aisle identified by an additional "van accessible" sign
mounted below the symbol of accessibility is required. |
AC6 |
4.1.2(5)(a)(b),
4.6.3, 4.6.4 and 4.30.7 |
|
|
|
|
247 |
Aaron
Art Center |
Exterior |
Parking
Lot C-2 |
Parking Space |
The
cross slope of the accessible parking space and the adjacent access aisle
varies between 1:22 and 1:31. Accessible parking spaces and access aisle are
required to be level with surface slopes not exceeding 1:50 (2%) in all
directions. |
AC6 |
4.1.2(5)(a)(b)
and 4.6.3 |
|
|
|
|
254 |
Aaron
Art Center |
Exterior |
Ramp |
|
The
top of the handrails is approximately 32 inches above the ramp surface. The
top of handrail gripping surfaces shall be between 34 and 38 inches above the
ramp surface. |
AC13
through AC15 |
4.1.2(1),
4.3.7 and 4.8.5(5) |
|
|
|
|
255 |
Aaron
Art Center |
Exterior |
Ramp |
Handrail |
The
handrails do not extend 12 inches beyond the bottom of the ramp segments. The
handrails shall extend at least 12 inches beyond the bottom of the ramp
segment, and the extensions shall be parallel with the ground surface. |
AC14
and AC16 |
4.1.2(1),
4.3.7, 4.8.5(2) and Fig. 17 |
|
|
|
|
256 |
Aaron
Art Center |
Aaron
Art Museum |
Entrance |
Door |
The
clear opening width of a single leaf of the double leaf door is 29 inches.
The clear opening width of at least one leaf of the door is required to be 32
inches minimum measured between the face of the door and the opposite stop
when the door is open 90 degrees. |
AC17
and AC18 |
4.1.3(8),
4.1.3(7)(a), 4.13.4, 4.13.5 and Fig. 24(a) |
|
|
|
|
294 |
Lisser
Hall |
Exterior |
Designated
Accessible Entrance Ramp |
Ramp |
The
slope of each ramp segment is approximately 1:10. The maximum allowable ramp
slope is 1:12. |
LH3
and LH4 |
4.1.2(1),
4.3.7 and 4.8.2 |
|
|
|
|
295 |
Lisser
Hall |
Exterior |
Designated
Accessible Entrance |
|
The
intermediate ramp landings are less than 60 inches in length. The minimum
landing size shall be 60 inches by 60 inches. |
LH3
through LH6 |
4.1.2(1),
4.3.7 and 4.8.4(3) |
|
|
|
|
296 |
Lisser
Hall |
Exterior |
Designated
Accessible Entrance |
|
A
½-inch vertical change in level is located in the middle ramp segment. A
change in level that is no higher than ¼ inch vertical or ½ inch beveled with
a slope no greater than 1:2 is required. |
LH7 |
4.1.2(1),
4.1.3(8), 4.3.8 and 4.5.2 |
|
|
|
|
297 |
Lisser
Hall |
Exterior |
Designated
Accessible Entrance |
|
The
top of the ramp handrails is approximately 33 inches above the ramp surface.
The top of handrail gripping surfaces shall be between 34 and 38 inches above
the ramp surface. |
LH3
and LH4 |
4.1.2(1),
4.3.7 and 4.8.5(5) |
|
|
|
|
298 |
Lisser
Hall |
Exterior |
Designated
Accessible Entrance |
|
The
handrail extensions beyond the bottom ramp segment are not parallel with the
ground surface. The handrails shall extend at least 12 inches beyond the
bottom of the ramp segment, and the extensions shall be parallel with the
ground surface. |
LH3
and LH8 |
4.1.2(1),
4.3.7, 4.8.5(2) and Fig. 18 |
|
|
|
|
299 |
Lisser
Hall |
Exterior |
Designated
Accessible Entrance |
|
The
handrails do not extend beyond the top of the ramp segment. The handrails
shall extend at least 12 inches beyond the top of the ramp segment, and the
extensions shall be parallel with the ground surface. |
LH9
and LH10 |
4.1.2(1),
4.3.7, 4.8.5(2) and Fig. 17 |
|
|
|
|
300 |
Lisser
Hall |
Exterior |
Designated
Accessible Entrance |
|
A
⅝-inch change in level is located at the door threshold. A change in
level that is no higher than ¼ inch vertical or ½ inch beveled with a slope
no greater than 1:2 is required. |
LH11 |
4.1.2(1),
4.1.3(8), 4.3.8 and 4.5.2 |
|
|
|
|