Attachment C - Completion Date December 31, 2023

No. Building General Location  Specific Location Specific Accessible Areas DOJ Report Item Photo 1991 Standards Section 2010 Standards requirement where different from 1991 2010 Standards Section Date Completed Notes
24 Trefethen Aquatic Center Pool Building Men's and Women's Locker Room Designated Accessible Stall Designated Accessible Toilet Stall The toilet centerline is 20 inches from the side wall. The toilet centerline is required to be exactly 18 inches from the side wall.  TAC7 and TAC8 4.1.3(11), 4.23.4, 4.17.3 and Fig. 30(a-1) The centerline of the toilet shall be 16 inches minimum to 18 inches maximum from the side wall or partition. 213.3.2 and 604.2    
35 Natural Science Building Exterior Route from Sidewalk to Entrance Walkway (Addition) Walkway (Addition) The slope of the walkway varies between 1:16 and 1:20, and no handrails are provided along the portions of the walkway where the slope exceeds 1:20. Handrails are required on both sides of each walkway segment that has a slope greater than 1:20.  NSB1 4.1.5, 4.1.2(1), 4.3.7 and 4.8.5        
123 Haas Pavilion First Floor Gymnasium Bleachers The side bleachers have 214 fixed seats, and the two end bleachers have an approximate capacity of 240 fixed seats each. Four designated wheelchair locations are provided. Eight wheelchair locations dispersed throughout the side and end bleachers are required.  HP4 through HP6 4.1.3(19)(a), 4.33.2, 4.33.3 and 4.33.4        
124 Haas Pavilion First Floor Gymnasium Bleachers No seats with movable armrests are provided. Seven aisle seats with no armrests on the aisle side, or removable or folding armrests on the aisle side are required.  HP7 4.1.3(19)(a) At least 5 percent of the total number of aisle seats provided shall have folding or retractable armrests on the aisle side. 221.4 and 802.4    
125 Haas Pavilion First Floor Gymnasium Bleachers The four designated wheelchair locations are located on the floor and are not a part of the fixed seating plan. Wheelchair locations are required to be an integral part of the fixed seating plan.  HP8 through HP10 4.1.3(19)(a) and 4.33.3        
126 Haas Pavilion First Floor Gymnasium Bleachers A companion seat is not provided adjacent to the two end designated wheelchair locations. At least one fixed companion seat shall be provided adjacent to each wheelchair location.  HP8 and HP10 4.1.3(19)(a) and 4.33.3 Companion seats shall be equivalent in size, quality, comfort and amenities to the seating in the immediate area. Companion seats are permitted to be moveable. 221.2.1, 221.3 and 802.3    
127 Haas Pavilion First Floor Gymnasium Bleachers The companion seat adjacent to the two middle designated wheelchair locations is not provided at the same finish floor elevation as the wheelchair locations.  HP9 4.1.3(19)(a) and 4.33.3        
207 Music Building First Floor Center for Contemporary Music (CCM) and Ensemble Room Route An accessible route to the first and second floor of the Center for Contemporary Music and Ensemble Room is not provided. An accessible route is required.  MB2 and MB3 4.1.3(1) and 4.3        
236 Aaron Art Center Exterior Parking Lot C-1 Van Space No van accessible parking space is provided. One van-accessible parking space with a 96-inch wide access aisle identified by an additional "van accessible" sign mounted below the symbol of accessibility is required.  AC1 and AC2 4.1.2(5)(a)(b), 4.6.3, 4.6.4 and 4.30.7(1)        
237 Aaron Art Center Exterior Parking Lot C-1 Access Aisle The designated accessible parking space located on the southeast side of Kapiolani Road has a 39-inch wide access aisle. A demarcated access aisle that is either a minimum of 60 inches wide for an accessible parking spaces or a minimum of 96 inches wide for a van accessible space is required.  AC1  4.1.2(5)(a)(b), 4.6.3 and Fig. 9        
238 Aaron Art Center Exterior Parking Lot C-1 Slope The surface slopes of the designated accessible parking spaces and access aisles vary between 1:20 and 1:38. Accessible parking spaces and access aisles are required to be level with surface slopes not exceeding 1:50 (2%) in all directions AC1 and AC2 4.1.2(5)(a)(b) and 4.6.3        
239 Aaron Art Center Exterior Parking Lot C-1 Slope The slope of the route from the accessible parking space located on the southeast side of Kapiolani Road to the sidewalk is approximately 1:5. The maximum allowable slope of an accessible route is 1:20.  AC1 and AC3 4.1.2(1) and 4.3.7        
241 Aaron Art Center Exterior Curb Ramp in front of Olney Hall Slope The slope of the side flare is approximately 1:7. The maximum allowable side flare slope is 1:12 when a landing is not provided at the top of the curb ramp.  AC4 4.1.2(1), 4.3.7, 4.7.5 and Fig. 12        
243 Aaron Art Center Exterior Curb Ramp in front of Aaron Art Center Slope The slope of the curb ramp is approximately 1:7. The maximum allowable ramp slope is 1:12.  AC5 4.1.2(1), 4.3.7, 4.7.2 and 4.8.2        
244 Aaron Art Center Exterior Curb Ramp in front of Aaron Art Center Slope The slope of the side flare is approximately 1:8. The maximum allowable side flare slope is 1:10.  AC5 4.1.2(1), 4.3.7, 4.7.5 and Fig. 12        
246 Aaron Art Center Exterior Parking Lot C-2 Parking Space No "van accessible" sign is provided. One van accessible parking space with a 96-inch wide access aisle identified by an additional "van accessible" sign mounted below the symbol of accessibility is required.  AC6 4.1.2(5)(a)(b), 4.6.3, 4.6.4 and 4.30.7        
247 Aaron Art Center Exterior Parking Lot C-2 Parking Space The cross slope of the accessible parking space and the adjacent access aisle varies between 1:22 and 1:31. Accessible parking spaces and access aisle are required to be level with surface slopes not exceeding 1:50 (2%) in all directions.  AC6 4.1.2(5)(a)(b) and 4.6.3        
254 Aaron Art Center Exterior Ramp   The top of the handrails is approximately 32 inches above the ramp surface. The top of handrail gripping surfaces shall be between 34 and 38 inches above the ramp surface.  AC13 through AC15 4.1.2(1), 4.3.7 and 4.8.5(5)        
255 Aaron Art Center Exterior Ramp Handrail The handrails do not extend 12 inches beyond the bottom of the ramp segments. The handrails shall extend at least 12 inches beyond the bottom of the ramp segment, and the extensions shall be parallel with the ground surface.  AC14 and AC16 4.1.2(1), 4.3.7, 4.8.5(2) and Fig. 17        
256 Aaron Art Center Aaron Art Museum Entrance Door The clear opening width of a single leaf of the double leaf door is 29 inches. The clear opening width of at least one leaf of the door is required to be 32 inches minimum measured between the face of the door and the opposite stop when the door is open 90 degrees.  AC17 and AC18 4.1.3(8), 4.1.3(7)(a), 4.13.4, 4.13.5 and Fig. 24(a)        
294 Lisser Hall Exterior Designated Accessible Entrance Ramp Ramp The slope of each ramp segment is approximately 1:10. The maximum allowable ramp slope is 1:12.  LH3 and LH4 4.1.2(1), 4.3.7 and 4.8.2        
295 Lisser Hall Exterior Designated Accessible Entrance   The intermediate ramp landings are less than 60 inches in length. The minimum landing size shall be 60 inches by 60 inches.  LH3 through LH6 4.1.2(1), 4.3.7 and 4.8.4(3)        
296 Lisser Hall Exterior Designated Accessible Entrance   A ½-inch vertical change in level is located in the middle ramp segment. A change in level that is no higher than ¼ inch vertical or ½ inch beveled with a slope no greater than 1:2 is required.  LH7 4.1.2(1), 4.1.3(8), 4.3.8 and 4.5.2        
297 Lisser Hall Exterior Designated Accessible Entrance   The top of the ramp handrails is approximately 33 inches above the ramp surface. The top of handrail gripping surfaces shall be between 34 and 38 inches above the ramp surface.  LH3 and LH4 4.1.2(1), 4.3.7 and 4.8.5(5)        
298 Lisser Hall Exterior Designated Accessible Entrance   The handrail extensions beyond the bottom ramp segment are not parallel with the ground surface. The handrails shall extend at least 12 inches beyond the bottom of the ramp segment, and the extensions shall be parallel with the ground surface.  LH3 and LH8 4.1.2(1), 4.3.7, 4.8.5(2) and Fig. 18        
299 Lisser Hall Exterior Designated Accessible Entrance   The handrails do not extend beyond the top of the ramp segment. The handrails shall extend at least 12 inches beyond the top of the ramp segment, and the extensions shall be parallel with the ground surface.  LH9 and LH10 4.1.2(1), 4.3.7, 4.8.5(2) and Fig. 17        
300 Lisser Hall Exterior Designated Accessible Entrance   A ⅝-inch change in level is located at the door threshold. A change in level that is no higher than ¼ inch vertical or ½ inch beveled with a slope no greater than 1:2 is required.  LH11 4.1.2(1), 4.1.3(8), 4.3.8 and 4.5.2