Attachment A - Completion Date December 31, 2014

No. Building General Location  Specific Location DOJ Report Item Photo 1991 Standards Section 2010 Standards requirement where different from 1991 2010 Standards Section Date Completed Notes
20 Trefethen Aquatic Center Exterior Pool Deck No shower grab bars are provided. An accessible shower with grab bars along the control wall and side wall is required.  TAC 5 4.1.3(11), 4.23.8, 4.21.4, 4.26 and Fig. 37(b)        
21 Trefethen Aquatic Center Exterior Pool Deck A shower spray unit is not provided. A shower spray unit with a hose at least 60 inches long that can be used as a fixed shower head and as a hand held shower is required TAC 6 4.1.3(11), 4.23.8 and 4.21.6 A shower spray unit with a hose 59 inches long minimum that can be used both as a fixed-position shower head an as a handheld shower shall be provided. The shower spray unit shall have an on/off control with a non-positive shut-off.  213.3.6 and 608.6    
22 Trefethen Aquatic Center Pool Building Men's and Women's Locker Room The force required to open the vestibule door is 15 lbf. The maximum allowable force for opening an interior door is 5 lbf.  none 4.1.3(7)(b) and 4.13.11(2)(b)        
23 Trefethen Aquatic Center Pool Building Men's and Women's Locker Room The typical towel hook is 69 inches above the finish floor. A hook no higher than 54 inches above the finish floor for a side reach is required. (Men's Locker Room)  TAC 6 4.1.3(12)(a), 4.25.3, 4.2.6 and Fig. 6 A hook no higher than 48 inches above the finish floor for an unobstructed reach is required. (Men's Locker Room)  222.2, 803.5 and 308    
27 Trefethen Aquatic Center Pool Building Men's and Women's Locker Room The paper towel dispenser control is located 58 inches above the finish floor. A paper towel dispenser with a control that is located no higher than 54 inches above the finish floor for a side reach is required.  TAC 9 and TAC10 4.1.3(11), 4.23.7, 4.27.3, 4.2.6 and Fig. 6 A dispenser with a control no higher than 48 inches above the finish floor for an unobstructed reach is required. 205.1, 309.3 and 308    
31 Trefethen Aquatic Center Pool Building Men's and Women's Locker Room Shower Area The space between the control wall and the shower seat is 3¼ inches. The space between the wall and shower seat shall be no more than 1½ inches.  TAC 13 and TAC 14 4.1.3(11), 4.23.4, 4.17.6, 4.26.2 and Fig. 39(e)        
32 Trefethen Aquatic Center Pool Building Men's and Women's Locker Room Shower Area The towel hooks are more than 54 inches above the finish floor. A hook no higher than 54 inches above the finish floor for a side reach is required. (Women's Locker Room)  TAC 15 and TAC 16 4.1.3(12)(a), 4.25.3, 4.2.6 and Fig. 6 A hook no higher than 48 inches above the finish floor for an unobstructed reach is required. (Women Locker Room)  222.2, 803.5 and 308    
33 Trefethen Aquatic Center Pool Building Men's and Women's Locker Room Shower Area A 12-inch deep bench is provided. A 24-inch by 48-inch bench fixed to the wall along the longer dimension is required. (Women's Locker Room)  TAC 16 4.1.3(21) and 4.35.4 Benches shall have seats that are 42 inches long minimum and 20 inches deep minimum to 24 inches deep maximum. The bench shall provide back support or shall be affixed to a wall. 222.1, 803.4 and 903    
37 Natural Science Building Addition - First Floor Physics Laboratory - Room 105 The utility hooks are 77 inches above the finish floor. A hook no higher than 54 inches above the finish floor for a side reach is required.  NSB2 4.1.5, 4.1.3(12)(a), 4.25.3, 4.2.6 and Fig. 6 A hook no higher than 48 inches above the finish floor for an unobstructed reach is required. 225.2, 811.3 and 308    
43 Natural Science Building Addition - First Floor Chemistry Research Laboratory - Room 106 The utility hooks are 71 inches above the finish floor. A hook no higher than 54 inches above the finish floor for a side reach is required.  NSB5 4.1.5, 4.1.3(12)(a), 4.25.3, 4.2.6 and Fig. 6 A hook no higher than 48 inches above the finish floor for an unobstructed reach is required. 225.2, 811.3 and 308    
44 Natural Science Building Addition - First Floor Chemistry Research Laboratory - Room 106 The lowest peg on the drying rack is located 52 inches above the finish floor. A peg that is located no higher than 46 inches above the finish floor for a side reach over an obstruction is required.  NSB6 4.1.5, 4.1.3(12)(a), 4.25.3, 4.2.6 and Fig. 6        
45 Natural Science Building Addition - First Floor Chemistry Research Laboratory - Room 106 The paper towel dispenser control is located 59 inches above the finish floor. A paper towel dispenser with a control that is located no higher than 46 inches above the finish floor for a side reach over an obstruction is required.  NSB6 4.1.5, 4.1.3(13), 4.27.3, 4.2.6 and Fig. 6 A dispenser with a control no higher than 48 inches above the finish floor for an unobstructed reach is required. 205.1, 309.3 and 308    
50 Natural Science Building Addition - First Floor Advanced Chemistry Laboratory - Room 101 The paper towel dispenser control is located 60 inches above the finish floor. A paper towel dispenser with a control that is located no higher than 54 inches above the finish floor for a side reach is required.  NSB9 4.1.5, 4.1.3(13), 4.27.3, 4.2.6 and Fig. 6 A dispenser with a control no higher than 48 inches above the finish floor for an unobstructed reach is required. 205.1, 309.3 and 308    
51 Natural Science Building Addition - First Floor Advanced Chemistry Laboratory - Room 101 A 29-inch deep reach is provided to the typical lab station electrical outlets. An electrical outlet with a 24-inch maximum side reach is required at an accessible lab station.  NSB10 4.1.5, 4.1.3(18), 4.2.6 and Fig. 6(c)        
55 Natural Science Building Addition - First Floor Corridor An exit sign is not mounted on the wall adjacent to the latch side of the door. A sign mounted on the wall adjacent to the latch side of the door identifying the exit in raised characters and Braille is required.  NSB12 4.1.5, 4.1.3(16)(a), 4.30.1, 4.30.4, 4.30.5 and 4.30.6 Tactile characters on signs shall be located between 48 inches minimum and 60 inches maximum above the finish floor, measured to the baseline of the tactile character. 216.2, 703.1-5    
58 Natural Science Building Addition - Second Floor Chemistry Laboratory - Room 206 The utility hooks are 72 inches above the finish floor. A hook no higher than 54 inches above the finish floor for a side reach is required.  NSB14 4.1.5, 4.1.3(12)(a), 4.25.3, 4.2.6 and Fig. 6 A hook no higher than 48 inches above the finish floor for an unobstructed reach is required. 225.2, 811.3 and 308    
59 Natural Science Building Addition - Second Floor Chemistry Laboratory - Room 206 The paper towel dispenser control is located 52 inches above the finish floor. A paper towel dispenser with a control that is located no higher than 46 inches above the finish floor for a side reach over an obstruction is required.  NSB15 4.1.5, 4.1.3(13), 4.27.3, 4.2.6 and Fig. 6(c) A dispenser with a control no higher than 48 inches above the finish floor for an unobstructed reach is required. 205.1, 309.3 and 308    
64 Natural Science Building Addition - Second Floor Organic Chemistry Laboratory  - Room 201 A 29-inch deep reach is provided to the typical lab station electrical outlets. An electrical outlet with a 24-inch maximum side reach is required at an accessible lab station. NSB16 4.1.5, 4.1.3(18), 4.2.6 and Fig. 6(c)        
68 Natural Science Building Addition - First and Second Floors Men's Toilet Room The force required to open the toilet room door is 15 lbf. The maximum allowable force for opening an interior door is 5 lbf.  none 4.1.5, 4.1.3(7)(b) and 4.13.11(2)(b)        
70 Natural Science Building Addition - First and Second Floors Men's Toilet Room Designated Accessible Toilet Stall The rear grab bar is mounted 38 inches above the finish floor to the centerline of the bar. The rear grab bar shall be mounted 33 to 36 inches above the finish floor to the centerline. NSB18 4.1.5, 4.1.3(11), 4.22.4, 4.17.6 and Fig. 30(c).  Grab bars shall be installed 33 inches minimum and 36 inches maximum above the finish floor to the top of the gripping surface. 213.3.1, 604.8.1.5 and 609.4    
73 Natural Science Building Addition - First and Second Floors Women's Toilet Room The force required to open the toilet room door is 12 lbf. The maximum allowable force for opening an interior door is 5 lbf.  none 4.1.5, 4.1.3(7)(b) and 4.13.11(2)(b)        
74 Natural Science Building Addition - First and Second Floors Women's Toilet Room Designated Accessible Toilet Stall The toilet flush control is mounted on top of the toilet tank. Flush controls are required to be mounted on the wide side of the toilet area.  NSB20 4.1.5, 4.1.3(11), 4.22.4, 4.17.2 and 4.16.5        
75 Natural Science Building Addition - First and Second Floors Women's Toilet Room Designated Accessible Toilet Stall The rear grab bar is mounted 38 inches above the finish floor to the centerline of the bar. The rear grab bar shall be mounted 33 to 36 inches above the finish floor to the centerline.  NSB21 4.1.5, 4.1.3(11), 4.22.4, 4.17.6 and Fig. 30(c) Grab bars shall be installed 33 inches minimum and 36 inches maximum above the finish floor to the top of the gripping surface. 213.3.1, 604.8.1.5 and 609.4    
84 Natural Science Building Existing Building - First and Second Floors Zoology Laboratory - Room 171 (typical laboratory) The emergency shower handle is 67 inches above the finish floor. An emergency shower handle that is mounted no higher than 54 inches above the finish floor for a side reach is required.  NSB27 4.1.3(13), 4.27.3, 4.2.6 and Fig. 6 An emergency shower with a control no higher than 48 inches above the finish floor for an unobstructed reach is required. 205.1, 309.3 and 308    
86 Natural Science Building Existing Building - First and Second Floors Zoology Laboratory - Room 171 (typical laboratory) A 26-inch deep reach is provided to the typical lab station outlets and controls. An electrical outlet with a 24-inch maximum side reach is required at an accessible lab station.  NSB28 4.1.3(18), 4.2.6 and Fig. 6(c)        
90 Natural Science Building Existing Building - First and Second Floors Women's Toilet Room A toilet room sign is not mounted on the wall adjacent to the latch side of the door. A sign mounted on the wall adjacent to the latch side of the door identifying the toilet room in raised characters and Braille is required.  NSB33 4.1.3(16)(a), 4.30.1, 4.30.4, 4.30.5 and 4.30.6 Tactile characters on signs shall be located between 48 inches minimum and 60 inches maximum above the finish floor, measured to the baseline of the tactile character. 216.2, 703.1-5    
91 Natural Science Building Existing Building - First and Second Floors Women's Toilet Room The women's toilet room is not accessible, and a directional sign to the designated accessible women's toilet room is not provided. A sign indicating the location of the designated accessible women's toilet room is required. NSB33 4.1.2(7)(d) and 4.1.6(3)(e)(iii)        
92 Alderwood Hall Entrance Side Entrance The sign indicating the route to the designated accessible entrance is obscured by foliage. A directional sign indicating the route to the designated accessible entrance is required.  AH1 Title III Regulations 36.211 and 4.1.2(7)(c) and 4.1.6(1)(h)        
93 Alderwood Hall Entrance Designated Accessible Entrance Ramp A level ramp landing is not provided at the bottom of the ramp run. Ramps are required to have level landings at the top and bottom of each ramp run.  AH2 and AH3 4.1.2(1), 4.3.7 and 4.8.4        
94 Alderwood Hall Entrance Designated Accessible Entrance Ramp The intermediate ramp landing is 53½ inches long. The minimum landing length shall be 60 inches clear.  AH4 4.1.2(1), 4.3.7 and 4.8.4(2)        
95 Alderwood Hall Entrance Designated Accessible Entrance Ramp The slope of the upper ramp segment is approximately 1:10. The maximum allowable ramp slope is 1:12.  AH2 4.1.2(1), 4.3.7 and 4.8.2        
96 Alderwood Hall Entrance Designated Accessible Entrance Ramp The top ramp landing is 49 inches long. The minimum landing length shall be 60 inches clear.  AH2 4.1.2(1), 4.3.7 and 4.8.4(2)        
97 Alderwood Hall Entrance Designated Accessible Entrance Ramp No handrail is provided on the wall side of the ramp. Handrails are required on both sides of the ramp.  AH2 through AH5 4.1.2(1), 4.3.7 and 4.8.6        
98 Alderwood Hall Entrance Designated Accessible Entrance Ramp The top of the ramp handrail is 32 inches above the ramp surface. The top of handrail gripping surfaces shall be between 34 and 38 inches above the ramp surface.  AH2 4.1.2(1), 4.3.7 and 4.8.5(5)        
99 Alderwood Hall Entrance Designated Accessible Entrance Ramp The handrail does not extend beyond the bottom of the ramp segment. The handrail shall extend at least 12 inches beyond the bottom of the ramp segment, and the extension shall be parallel with the ground surface.  AH2 and AH3 4.1.2(1), 4.3.7, 4.8.5(2) and Fig. 17        
100 Alderwood Hall First Floor Unisex Toilet Room A toilet room sign is not mounted on the wall adjacent to the latch side of the door. A sign mounted on the wall adjacent to the latch side of the door identifying the toilet room in raised characters and Braille is required.  AH5 and AH6 4.1.3(16)(a), 4.30.1, 4.30.4, 4.30.5 and 4.30.6 Tactile characters on signs shall be located between 48 inches minimum and 60 inches maximum above the finish floor, measured to the baseline of the tactile character. 216.2, 703.1-5    
101 Alderwood Hall First Floor Unisex Toilet Room The 60-inch diameter turning space is obstructed by furniture. An unobstructed 60‑inch diameter or t-shaped turning space is required.  AH7 and AH8 4.1.3(11), 4.22.3, 4.2.3 and Fig. 3        
102 Alderwood Hall First Floor Unisex Toilet Room The toilet clear floor space is obstructed by furniture. Clear floor space that is a minimum of 48 inches wide and 56 inches deep is required.  AH9 and AH10 4.1.3(11), 4.22.4, 4.16.2 and Fig. 28        
106 Alderwood Hall First Floor Unisex Toilet Room The toilet flush control is mounted on the narrow side of the toilet area. Flush controls are required to be mounted on the wide side of the toilet area. (Right Hand Toilet Room)  AH7 4.1.3(11), 4.22.4 and 4.16.5        
107 Alderwood Hall Second Floor Typical Classrooms A room number sign is not mounted on the wall adjacent to the latch side of the door. A sign mounted on the wall adjacent to the latch side of the door identifying the room number in raised characters and Braille is required.  AH11 4.1.3(16)(a), 4.30.1, 4.30.4, 4.30.5 and 4.30.6 Tactile characters on signs shall be located between 48 inches minimum and 60 inches maximum above the finish floor, measured to the baseline of the tactile character. 216.2, 703.1-5    
108 Alderwood Hall Second Floor Storage Closet The door has knob hardware which requires twisting of the wrist to operate. Door hardware that does not require tight grasping, pinching or twisting of the wrist to operate is required.  AH12 4.1.3(7)(b) and 4.13.9        
109 Alderwood Hall Second Floor Men's and Women's Toilet Rooms The toilet room sign is mounted 56 inches above the finish floor to the centerline of the sign. A sign mounted on the wall adjacent to the latch side of the door at 60 inches above the finish floor to the centerline of the sign is required.  AH13 and AH14 4.1.3(16)(a) and 4.30.6 Tactile characters on signs shall be located between 48 inches minimum and 60 inches maximum above the finish floor, measured to the baseline of the tactile character. 216.2, 703.1-5    
110 Alderwood Hall Second Floor Men's and Women's Toilet Rooms The force required to open the toilet room door is greater than 5 lbf. The maximum allowable force for opening an interior door is 5 lbf.  none 4.1.3(7)(b) and 4.13.11(2)(b)        
112 Alderwood Hall Second Floor Men's and Women's Toilet Rooms The 60-inch diameter turning space is obstructed by furniture. An unobstructed 60‑inch diameter or t-shaped turning space is required. (Women's Toilet Room)  AH15 and AH16 4.1.3(11), 4.22.3, 4.2.3 and Fig. 3        
113 Alderwood Hall Second Floor Men's and Women's Toilet Rooms The lavatory clear floor space is obstructed by furniture. Clear floor space that is a minimum of 30 inches wide and 48 inches deep is required. (Women's Toilet Room)  AH17 4.1.3(11), 4.22.6, 4.19.3 and Fig. 32        
115 Alderwood Hall Second Floor Girl's Toilet Rooms The toilet room sign is mounted 56 inches above the finish floor to the centerline of the sign. A sign mounted on the wall adjacent to the latch side of the door at 60 inches above the finish floor to the centerline of the sign is required.  AH18 4.1.3(16)(a) and 4.30.6 Tactile characters on signs shall be located between 48 inches minimum and 60 inches maximum above the finish floor, measured to the baseline of the tactile character. 216.2, 703.1-5    
118 Haas Pavilion Exterior Parking Lot A-3 No "van accessible" sign is provided. One van accessible parking space with a 96-inch wide access aisle identified by an additional "van accessible" sign mounted below the symbol of accessibility is required.  HP1 4.1.2(5)(a)(b), 4.6.3, 4.6.4 and 4.30.7        
119 Haas Pavilion Exterior Parking Lot A-3 The cross slope of the accessible parking space and the adjacent access aisle varies between 1:30 and 1:37. Accessible parking spaces and access aisle are required to be level with surface slopes not exceeding 1:50 (2%) in all directions. HP1 4.1.2(5)(a)(b) and 4.6.3        
120 Haas Pavilion Exterior Entrance The main entrance is up eleven risers, and directional signage is not provided indicating the route to the designated accessible entrance. A directional sign indicating the route to the designated accessible entrance is required.  HP2 4.1.2(5)(a)(b) and 4.6.3        
128 Haas Pavilion First Floor Gymnasium Signage notifying patrons of the availability of an assistive listening system is not provided. A permanently installed assistive listening, 28 receivers and signage notifying patrons of the availability of a listening system is required.  none 4.1.3(19)(b), 4.33.6, 4.33.7 and 4.30.7(4) An assistive listening system with 26 receivers, including 7 hearing-aid compatible receivers shall be provided. A sign informing patrons of the availability of the assistive listening system shall be provided.  216.10, 219, 703.5, 703.7.2.4 and 706    
130 Haas Pavilion First Floor Corridor The water flow is 3 inches high. The spout shall provide a flow of water at least 4 inches high so as to allow the insertion of a cup or glass under the flow of water.  HP11 4.1.3(10)(a) and 4.15.3        
132 Haas Pavilion First Floor Offices (typical) The room number sign is mounted higher than 60 inches above the finish floor to the centerline of the sign. A permanent room sign mounted at 60 inches above the finish floor to the centerline of the sign is required.  HP12 and HP13 4.1.3(16)(a) and 4.30.6 Tactile characters on signs shall be located between 48 inches minimum and 60 inches maximum above the finish floor, measured to the baseline of the tactile character. 216.2, 703.1-5    
133 Haas Pavilion First Floor Offices (typical) The clear opening width of the door is 29 inches. The clear opening width of the door is required to be 32 inches minimum measured between the face of the door and the opposite stop when the door is open 90 degrees.  HP12 and HP13 4.1.3(7)(b), 4.13.5 and Fig. 24(a)        
134 Haas Pavilion First Floor Offices (typical) The doors have knob hardware which requires twisting of the wrist to operate. Door hardware that does not require tight grasping, pinching or twisting of the wrist to operate is required. HP12 and HP13 4.1.3(7)(b) and 4.13.9        
135 Haas Pavilion First Floor Men's Toilet Room The toilet room sign is mounted 63 inches above the finish floor to the centerline of the sign. A toilet room sign mounted at 60 inches above the finish floor to the centerline of the sign is required.  HP14 4.1.3(16)(a) and 4.30.6 Tactile characters on signs shall be located between 48 inches minimum and 60 inches maximum above the finish floor, measured to the baseline of the tactile character. 216.2, 703.1-5    
140 Haas Pavilion First Floor Men's Toilet Room The typical urinal rim is located 25 inches above the finish floor. A urinal with a rim that is a maximum of 17 inches above the finish floor is required.  HP17 4.1.3(11), 4.22.5 and 4.18.2        
141 Haas Pavilion First Floor Men's Toilet Room The typical urinal flush control is located 53 inches above the finish floor. A urinal with a flush control that is a maximum of 44 inches above the finish floor is required.  HP17 4.1.3(11), 4.22.5 and 4.18.4        
142 Haas Pavilion First Floor Men's Toilet Room Knee clearance at the typical lavatory is 24 inches above the finish floor. A lavatory with knee clearance at least 27 inches above the finish floor is required.  HP18 4.1.3(11), 4.22.6 and 4.19.2        
143 Haas Pavilion First Floor Men's Toilet Room The typical lavatory faucet has a knob controls. Controls which do not require tight grasping, tight pinching or twisting of the wrist to operate are required.  HP18 4.1.3(11), 4.22.6, 4.19.5 and 4.27.4        
144 Haas Pavilion First Floor Women's Toilet Room The toilet room sign is mounted 63 inches above the finish floor to the centerline of the sign. A toilet room sign mounted at 60 inches above the finish floor to the centerline of the sign is required.  HP19 4.1.3(16)(a) and 4.30.6 Tactile characters on signs shall be located between 48 inches minimum and 60 inches maximum above the finish floor, measured to the baseline of the tactile character. 216.2, 703.1-5    
146 Haas Pavilion First Floor Women's Toilet Room The force required to open the vestibule door is 10 lbf. The maximum allowable force for opening an interior door is 5 lbf.  HP21 4.1.3(7)(b) and 4.13.11(2)(b)        
148 Haas Pavilion First Floor Women's Toilet Room Designated Accessible Toilet Stall The toilet seat is 16½ inches high. The toilet seat is required to be between 17 and 19 inches high.  HP21 4.1.3(11), 4.22.4, 4.17.2, 4.16.3 and Fig. 29(b)        
149 Haas Pavilion First Floor Women's Toilet Room Designated Accessible Toilet Stall The toilet centerline is 24 inches from the side partition. The toilet centerline is required to be exactly 18 inches from the side wall.  HP21 4.1.3(11), 4.22.4, 4.17.3 and Fig. 30(a-1) The centerline of the toilet shall be 16 inches minimum to 18 inches maximum from the side wall or partition. 213.3.2 and 604.2    
150 Haas Pavilion First Floor Women's Toilet Room The toilet paper dispenser is mounted 39 inches from the rear wall to the far end of the dispenser. The far end of the dispenser is required to be mounted no more than 36 inches from the rear wall.  HP21 4.1.3(11), 4.22.4, 4.17.6 and Fig. 30(d) The toilet paper dispenser shall be 7 inches minimum and 9 inches maximum in front of the toilet measured to the centerline of the dispenser. The outlet of the dispenser shall be 15 inches minimum and 48 inches maximum above the finish floor and shall not be located behind grab bars. 213.3.2 and 604.7    
150 Haas Pavilion First Floor Women's Toilet Room Designated Accessible Toilet Stall The toilet paper dispenser is mounted 39 inches from the rear wall to the far end of the dispenser. The far end of the dispenser is required to be mounted no more than 36 inches from the rear wall.  HP21 4.1.3(11), 4.22.4, 4.17.6 and Fig. 30(d) The toilet paper dispenser shall be 7 inches minimum and 9 inches maximum in front of the toilet measured to the centerline of the dispenser. The outlet of the dispenser shall be 15 inches minimum and 48 inches maximum above the finish floor and shall not be located behind grab bars. 213.3.2 and 604.7    
151 Haas Pavilion First Floor Women's Toilet Room Knee clearance at the typical lavatory is 24 inches above the finish floor. A lavatory with knee clearance at least 27 inches above the finish floor is required.  HP22 4.1.3(11), 4.22.6 and 4.19.2        
152 Haas Pavilion First Floor Women's Toilet Room The typical lavatory faucet has knob controls. Controls which do not require tight grasping, tight pinching or twisting of the wrist to operate are required. HP22 4.1.3(11), 4.22.6, 4.19.5 and 4.27.4        
153 Haas Pavilion Lower Level Corridor The drinking fountain protrudes 12½ inches from the wall and the leading edge is 33 inches above the finish floor. Objects mounted to walls with their leading edges between 27 inches and 80 inches above the finish floor shall protrude no more than 4 inches into the circulation path.  HP23 4.1.3(2) and 4.4.1        
154 Haas Pavilion Lower Level Corridor One inaccessible drinking fountain is provided. One drinking fountain accessible to individuals who use wheelchairs and one drinking fountain accessible to individuals who have trouble bending or stooping are required.  HP23 4.1.3(10)(a) and 4.15        
155 Haas Pavilion Lower Level Corridor The typical equipment counter is 41½ inches above the finish floor. A portion of the main counter which is a minimum of 36 inches long and a maximum of 36 inches high, an auxiliary counter with a maximum height of 36 inches in close proximity to the main counter or equivalent facilitation is required.  HP24 7.2(2) A portion of the counter that is 36 inches high maximum shall be provided. 227.3 and 904.4    
156 Haas Pavilion Lower Level Dance Studios and Offices (typical) A room number sign is not mounted on the wall adjacent to the latch side of the door. A sign mounted on the wall adjacent to the latch side of the door identifying the room number in raised characters and Braille is required.  HP25 and HP26 4.1.3(16)(a), 4.30.1, 4.30.4, 4.30.5 and 4.30.6 Tactile characters on signs shall be located between 48 inches minimum and 60 inches maximum above the finish floor, measured to the baseline of the tactile character. 216.2, 703.1-5    
158 Haas Pavilion Lower Level Dance Studios and Offices (typical) The doors have knob hardware which requires twisting of the wrist to operate. Door hardware that does not require tight grasping, pinching or twisting of the wrist to operate is required.  HP25 and HP26 4.1.3(7)(b) and 4.13.9        
159 Haas Pavilion Lower Level Men's Locker Room A toilet room sign is not mounted on the wall adjacent to the latch side of the door. A sign mounted on the wall adjacent to the latch side of the door identifying the toilet room in raised characters and Braille is required.  HP27 4.1.3(16)(a), 4.30.1, 4.30.4, 4.30.5 and 4.30.6 Tactile characters on signs shall be located between 48 inches minimum and 60 inches maximum above the finish floor, measured to the baseline of the tactile character. 216.2, 703.1-5    
160 Haas Pavilion Lower Level Men's Locker Room The clear opening width of the door is 29 inches. The clear opening width of the door is required to be 32 inches minimum measured between the face of the door and the opposite stop when the door is open 90 degrees.  HP27 4.1.3(7)(b), 4.13.5 and Fig. 24(a)        
161 Haas Pavilion Lower Level Men's Locker Room The force required to open the door is 10 lbf. The maximum allowable force for opening an interior door is 5 lbf.  none 4.1.3(7)(b) and 4.13.11(2)(b)        
164 Haas Pavilion Lower Level Men's Locker Room Toilet Area The typical urinal rim is located 24 inches above the finish floor. A urinal with a rim that is a maximum of 17 inches above the finish floor is required.  HP30 4.1.3(11), 4.23.5 and 4.18.2        
165 Haas Pavilion Lower Level Men's Locker Room Toilet Area The typical urinal flush control is located 52 inches above the finish floor. A urinal with a flush control that is a maximum of 44 inches above the finish floor is required.  HP30 4.1.3(11), 4.23.5 and 4.18.4        
167 Haas Pavilion Lower Level Men's Locker Room Toilet Area Knee clearance at the typical lavatory is 26 inches above the finish floor. A lavatory with knee clearance at least 27 inches above the finish floor is required.  HP31 4.1.3(11), 4.23.6 and 4.19.2        
168 Haas Pavilion Lower Level Men's Locker Room Toilet Area The drain pipe and hot water pipe underneath the typical lavatory are not insulated or configured against contact. Drain and hot water pipes shall be insulated or otherwise configured against contact.  HP31 4.1.3(11), 4.23.6 and 4.19.4 Water supply and drain pipes under lavatories shall be insulated or otherwise configured against. 213.3.4 and 606.5    
169 Haas Pavilion Lower Level Men's Locker Room Toilet Area The typical lavatory faucet has knob controls. Controls which do not require tight grasping, tight pinching or twisting of the wrist to operate are required.  HP31 4.1.3(11), 4.23.6, 4.19.5 and 4.27.4        
170 Haas Pavilion Lower Level Men's Locker Room Toilet Area The typical soap dispenser control is located 46 inches above the finish floor. A soap dispenser with a control that is located no higher than 44 inches above the finish floor for a forward reach over an obstruction is required.  HP31 4.1.3(11), 4.23.7, 4.27.3, 4.2.5 and Fig. 5(b)        
171 Haas Pavilion Lower Level Men's Locker Room Toilet Area The paper towel dispenser control is located 58 inches above the finish floor. A paper towel dispenser with a control that is located no higher than 54 inches above the finish floor for a side reach is required. HP31 4.1.3(11), 4.23.7, 4.27.3, 4.2.6 and Fig. 6 A dispenser with a control no higher than 48 inches above the finish floor for an unobstructed reach is required. 205.1, 309.3 and 308    
172 Haas Pavilion Lower Level Men's Locker Room One inaccessible drinking fountain is provided. One drinking fountain accessible to individuals who use wheelchairs and one drinking fountain accessible to individuals who have trouble bending or stooping are required.  HP32 4.1.3(10)(a) and 4.15        
173 Haas Pavilion Lower Level Men's Locker Room The typical locker has a control which requires pinching and twisting of the wrist to operate. A locker with a control which does not require tight grasping, tight pinching or twisting of the wrist to operate is required.  HP33 and HP34 4.1.3(12), 4.25.4 and 4.27.4        
175 Haas Pavilion Lower Level Men's Locker Room Shower Area No shower grab bars are provided. An accessible shower with grab bars along the control wall and side wall is required.  HP35 4.1.3(11), 4.23.8, 4.21.4, 4.26 and Fig. 37(b)        
176 Haas Pavilion Lower Level Men's Locker Room Shower Area The typical shower faucet has knob controls. Controls which do not require tight grasping, tight pinching or twisting of the wrist to operate are required.  HP35 4.1.3(11), 4.23.8, 4.21.5 and 4.27.4        
177 Haas Pavilion Lower Level Men's Locker Room Shower Area A shower spray unit is not provided. A shower spray unit with a hose at least 60 inches long that can be used as a fixed shower head and as a hand held shower is required.  HP35 4.1.3(11), 4.23.8 and 4.21.6 A shower spray unit with a hose 59 inches long minimum that can be used both as a fixed-position shower head an as a handheld shower shall be provided. The shower spray unit shall have an on/off control with a non-positive shut-off.  213.3.6 and 608.6    
178 Haas Pavilion Lower Level Women's Locker Room A toilet room sign is not mounted on the wall adjacent to the latch side of the door. A sign mounted on the wall adjacent to the latch side of the door identifying the toilet room in raised characters and Braille is required.  HP36 4.1.3(16)(a), 4.30.1, 4.30.4, 4.30.5 and 4.30.6 Tactile characters on signs shall be located between 48 inches minimum and 60 inches maximum above the finish floor, measured to the baseline of the tactile character. 216.2, 703.1-5    
181 Haas Pavilion Lower Level Women's Locker Room The force required to open the corridor door and the vestibule door is 10 lbf. The maximum allowable force for opening an interior door is 5 lbf.  none 4.1.3(7)(b) and 4.13.11(2)(b)        
194 Haas Pavilion Lower Level Women's Locker Room The typical locker has a control which requires pinching and twisting of the wrist to operate. A locker with a control which does not require tight grasping, tight pinching or twisting of the wrist to operate is required.  HP42 4.1.3(12), 4.25.4 and 4.27.4        
195 Haas Pavilion Lower Level Women's Locker Room A bench fixed to the wall is not provided. A 24-inch by 48-inch bench fixed to the wall along the longer dimension is required.  HP43 4.1.3(21) and 4.35.4 Benches shall have seats that are 42 inches long minimum and 20 inches deep minimum to 24 inches deep maximum. The bench shall provide back support or shall be affixed to a wall. 222.1, 803.4 and 903    
197 Haas Pavilion Lower Level Women's Locker Room The typical hair dryer control is located 62 inches above the finish floor. A hair dryer with a control that is located no higher than 54 inches above the finish floor for a side reach is required.  HP44 4.1.3(11), 4.23.7, 4.27.3, 4.2.6 and Fig. 6 A hair dryer with a control no higher than 48 inches above the finish floor for an unobstructed reach is required. 205.1, 309.3 and 308    
198 Haas Pavilion Lower Level Women's Locker Room Shower The typical shower compartment is 31 inches wide by 35 inches deep. Either an accessible transfer shower that is exactly 36 inches wide by 36 inches deep or an accessible roll-in shower that is a minimum of 60 inches wide by 30 inches deep shall be provided.  HP45 4.1.3(11), 4.23.8, 4.21.2, and Fig. 35(a)(b)        
199 Haas Pavilion Lower Level Women's Locker Room Shower Area No shower seat is provided. A seat shall be provided in shower stalls 36 inches wide by 36 inches deep HP45 4.1.3(11), 4.23.8, 4.21.3, 4.26 and Fig. 36        
200 Haas Pavilion Lower Level Women's Locker Room Shower Area No shower grab bars are provided. An accessible shower with grab bars along the control wall and side wall is required.  HP45 4.1.3(11), 4.23.8, 4.21.4, 4.26 and Fig. 37(a)(b)        
201 Haas Pavilion Lower Level Women's Locker Room Shower Area The typical shower faucet has knob controls. Controls which do not require tight grasping, tight pinching or twisting of the wrist to operate are required.  HP45 4.1.3(11), 4.23.8, 4.21.5 and 4.27.4        
202 Haas Pavilion Lower Level Women's Locker Room Shower Area A shower spray unit is not provided. A shower spray unit with a hose at least 60 inches long that can be used as a fixed shower head and as a hand held shower is required.  HP45 4.1.3(11), 4.23.8 and 4.21.6 A shower spray unit with a hose 59 inches long minimum that can be used both as a fixed-position shower head an as a handheld shower shall be provided. The shower spray unit shall have an on/off control with a non-positive shut-off.  213.3.6 and 608.6    
203 Haas Pavilion Lower Level Women's Locker Room Dressing Area The clear opening width of the typical dressing compartment door is 23 inches. The clear opening width of the door is required to be 32 inches minimum measured between the face of the door and the opposite stop when the door is open 90 degrees.  HP46 4.1.3(7)(b), 4.13.5 and Fig. 24(a)        
204 Haas Pavilion Lower Level Women's Locker Room Dressing Area An unobstructed turning space is not provided in the typical dressing compartment. A 60-inch diameter or t-shaped turning space is required.  HP46 4.1.3(21), 4.35.2, 4.2.3 and Fig. 3        
205 Haas Pavilion Lower Level Women's Locker Room Dressing Area A bench fixed to the wall is not provided. A 24-inch by 48-inch bench fixed to the wall along the longer dimension is required.  none 4.1.3(21) and 4.35.4 Benches shall have seats that are 42 inches long minimum and 20 inches deep minimum to 24 inches deep maximum. The bench shall provide back support or shall be affixed to a wall. 222.1, 803.4 and 903    
208 Music Building First Floor CCM Women's Toilet Room The women's toilet room is not accessible, and a directional sign to the designated accessible toilet is not provided. A sign indicating the location of the designated accessible toilet rooms on the second floor is required.  MB3 and MB4 4.1.6(3)(e)(iii)        
209 Music Building First Floor Concert Hall Lobby No signage is provided indicating the route to the designated accessible concert hall entrance. A directional sign indicating the route to the designated accessible second floor concert hall entrance is required.  MB5 4.1.2(7)(c) and 4.1.6(1)(h)        
210 Music Building Second Floor Women's Toilet Room The force required to open the toilet room door is 20 lbf. The maximum allowable force for opening an interior door is 5 lbf.  none 4.1.3(7)(b) and 4.13.11(2)(b)        
212 Music Building Second Floor Women's Toilet Room Ambulatory Toilet Stall The toilet seat is 16 inches high. The toilet seat is required to be between 17 and 19 inches high.  MB6 4.1.3(11), 4.22.4, 4.16.3 and Fig. 29(b)        
216 Music Building Second Floor Unisex Toilet Room The force required to open the toilet room door is 16 lbf. The maximum allowable force for opening an interior door is 5 lbf.  none 4.1.3(7)(b) and 4.13.11(2)(b)        
217 Music Building Second Floor Unisex Toilet Room The lavatory protrudes 23½ inches from the wall and the leading edge is 30 inches above the finish floor. Objects mounted to walls with their leading edges between 27 inches and 80 inches above the finish floor shall protrude no more than 4 inches into the circulation path.  MB9 4.1.3(2) and 4.4.1        
219 Music Building Second Floor Men's Toilet Room The force required to open the toilet room door is 16 lbf. The maximum allowable force for opening an interior door is 5 lbf.  none 4.1.3(7)(b) and 4.13.11(2)(b)        
220 Music Building Second Floor Men's Toilet Room The lavatory protrudes 23½ inches from the wall and the leading edge is 30 inches above the finish floor. Objects mounted to walls with their leading edges between 27 inches and 80 inches above the finish floor shall protrude no more than 4 inches into the circulation path.  MB11 4.1.3(2) and 4.4.1        
226 Music Building Second Floor Practice Studio Corridor The high drinking fountain protrudes 18 inches from the wall and the leading edge is more than 27 inches above the finish floor. Objects mounted to walls with their leading edges between 27 inches and 80 inches above the finish floor shall protrude no more than 4 inches into the circulation path.  MB17 4.1.3(2) and 4.4.1        
228 Music Building Littlefield Concert Hall Entrance Signage identifying the designated accessible concert hall entrance is not provided. The accessible concert hall entrance shall be identified by the International Symbol of Accessibility.  MB19 4.1.2(7)(c), 4.30.7(1) and Fig. 43(a)(b)        
229 Music Building Littlefield Concert Hall Auditorium Two aisle seats with movable armrests are provided. Five aisle seats with no armrests on the aisle side, or removable or folding armrests on the aisle side are required. MB20 4.1.3(19)(a) At least 5 percent of the total number of aisle seats provided shall have folding or retractable armrests on the aisle side. 221.4 and 802.4    
230 Music Building Littlefield Concert Hall Auditorium The stage is located six risers above the auditorium floor, and directional signage is not provided indicating the route to the designated accessible stage entrance. A directional sign indicating the route to the designated accessible stage entrance is required.  MB21 4.1.2(7)(c), 4.1.6(1)(h), 4.1.3(19)(a) and 4.33.5        
235 Music Building Littlefield Concert Hall Stage Signage identifying the designated accessible stage entrance is not provided. The designated accessible stage entrance shall be identified by the International Symbol of Accessibility.  MB25 4.1.2(7)(c), 4.30.7(1) and Fig. 43(a)(b)        
248 Aaron Art Center Exterior Route to Entrance The entrance to the Aaron Art Center is up four risers, and directional signage is not provided indicating the route to the designated accessible entrance ramp. A directional sign indicating the route to the designated accessible entrance ramp is required.  AC7 4.1.2(7)(c) and 4.1.6(1)(h)        
251 Aaron Art Center Exterior Route to Entrance The main entrance to the art museum is up seven risers, and directional signage is not provided indicating the route to the designated accessible art museum entrance. A directional sign indicating the route to the designated accessible entrance is required.  AC10 4.1.2(7)(c) and 4.1.6(1)(h)        
257 Aaron Art Center Aaron Art Center Vestibule The drinking fountain protrudes 20½ inches from the wall and the leading edge is 28 inches above the finish floor. Objects mounted to walls with their leading edges between 27 inches and 80 inches above the finish floor shall protrude no more than 4 inches into the circulation path.  AC19 and AC20 4.1.3(2) and 4.4.1        
258 Aaron Art Center Aaron Art Center Vestibule A standard height drinking fountain is not provided. One drinking fountain accessible to individuals who use wheelchairs and one drinking fountain accessible to individuals who have trouble bending or stooping are required.  AC19 and AC20 4.1.3(10)(a) and 4.15        
259 Aaron Art Center Aaron Art Center Vestibule The spout outlet is 37 inches high. The spout outlet shall be no higher than 36 inches above the finish floor.  AC19 4.1.3(10)(a) and 4.15.2        
260 Aaron Art Center Aaron Art Center Vestibule The water flow is 3 inches high. The spout shall provide a flow of water at least 4 inches high so as to allow the insertion of a cup or glass under the flow of water.  AC19 4.1.3(10)(a) and 4.15.3        
261 Aaron Art Center Aaron Art Center Danforth Lecture Hall The sign does not identify the room number in raised characters and Braille. A sign mounted on the wall adjacent to the latch side of the door identifying the room number in raised characters and Braille is required.  AC21 4.1.3(16)(a) and 4.30.4 Tactile characters on signs shall be located between 48 inches minimum and 60 inches maximum above the finish floor, measured to the baseline of the tactile character. 216.2, 703.1-5    
262 Aaron Art Center Aaron Art Center Danforth Lecture Hall The force required to open the door is 10 lbf. The maximum allowable force for opening an interior door is 5 lbf.  none 4.1.3(7)(b) and 4.13.11(2)(b)        
264 Aaron Art Center Aaron Art Center Danforth Lecture Hall The lecture hall contains 84 fixed seats, and no aisle seats with movable armrests are provided. One aisle seat with no armrests on the aisle side, or removable or folding armrests on the aisle side are required. AC23 4.1.3(19)(a) At least 5 percent of the total number of aisle seats provided shall have folding or retractable armrests on the aisle side. 221.4 and 802.4    
266 Aaron Art Center Aaron Art Center Danforth Lecture Hall Signage notifying patrons of the availability of an assistive listening system is not provided. A permanently installed assistive listening, four receivers and signage notifying patrons of the availability of a listening system is required.  none 4.1.3(19)(b), 4.33.6, 4.33.7 and 4.30.7(4) An assistive listening system with 4 receivers, including 2 hearing-aid compatible receivers shall be provided. A sign informing patrons of the availability of the assistive listening system shall be provided.  216.10, 219, 703.5, 703.7.2.4 and 706    
267 Aaron Art Center Aaron Art Center Women's Toilet Room A toilet room sign is not mounted on the wall adjacent to the latch side of the door. A sign mounted on the wall adjacent to the latch side of the door identifying the toilet room in raised characters and Braille is required.  AC33 4.1.3(16)(a), 4.30.1, 4.30.4, 4.30.5 and 4.30.6 Tactile characters on signs shall be located between 48 inches minimum and 60 inches maximum above the finish floor, measured to the baseline of the tactile character. 216.2, 703.1-5    
268 Aaron Art Center Aaron Art Center Women's Toilet Room The maneuvering clearance on the latch side of the door is 4½ inches. A minimum of 12 inches is required on the latch side of the door for a forward push approach when the door has both a closer and a latch. AC34 4.1.3(7)(b), 4.13.6 and Fig. 25(a)        
269 Aaron Art Center Aaron Art Center Women's Toilet Room The force required to open the toilet room door is 9 lbf. The maximum allowable force for opening a fire door is the minimum opening force allowable by the appropriate administrative authority.  none 4.1.3(7)(b) and 4.13.11(1)        
272 Aaron Art Center Aaron Art Center Men's Toilet Room A toilet room sign is not mounted on the wall adjacent to the latch side of the door. A sign mounted on the wall adjacent to the latch side of the door identifying the toilet room in raised characters and Braille is required.  AC36 4.1.3(16)(a), 4.30.1, 4.30.4, 4.30.5 and 4.30.6 Tactile characters on signs shall be located between 48 inches minimum and 60 inches maximum above the finish floor, measured to the baseline of the tactile character. 216.2, 703.1-5    
273 Aaron Art Center Aaron Art Center Men's Toilet Room The maneuvering clearance on the latch side of the door is 4½ inches. A minimum of 12 inches is required on the latch side of the door for a forward push approach when the door has both a closer and a latch. AC37 4.1.3(7)(b), 4.13.6 and Fig. 25(a)        
275 Aaron Art Center Aaron Art Center Men's Toilet Room The force required to open the toilet room door is 10 lbf. The maximum allowable force for opening a fire door is the minimum opening force allowable by the appropriate administrative authority.  none 4.1.3(7)(b) and 4.13.11(1)        
276 Aaron Art Center Aaron Art Center Men's Toilet Room Designated Accessible Toilet Stall The toilet flush control is mounted on the narrow side of the toilet area. Flush controls are required to be mounted on the wide side of the toilet area.  AC39 4.1.3(11), 4.22.4, 4.17.2 and 4.16.5        
280 Aaron Art Center Aaron Art Center Men's Toilet Room Designated Accessible Toilet Stall The coat hook is 66½ inches above the finish floor. A hook no higher than 54 inches above the finish floor for a side reach is required. AC40 4.1.3(12)(a), 4.25.3, 4.2.6 and Fig. 6 A hook no higher than 48 inches above the finish floor for an unobstructed reach is required.  222.2, 803.5 and 308    
283 Carnegie Hall Exterior Entrance The entrance door hardware is mounted 50 inches above the finish floor. Hardware shall be mounted no higher than 48 inches above the finish floor. CH-3 4.1.3(8), 4.1.3(7)(a) and 4.13.9        
284 Carnegie Hall Level One Elevator Floor designations are not provided on the first and second floor hoistway entrance jambs. Raised and Braille floor designations are required on both hoistway entrance jambs at 60 inches above the finish floor to the centerline of the character. CH4 through CH7 4.1.3(5), 4.10.5 and Figure 20 Tactile characters on signs shall be located between 48 inches minimum and 60 inches maximum above the finish floor, measured to the baseline of the tactile character. 206.6, 407.2.3, 703.2 and 703.4.1    
286 Carnegie Hall Level One M Center The display case protrudes 9 inches from the wall and the leading edge is 35½ inches above the finish floor. Objects mounted to walls with their leading edges between 27 inches and 80 inches above the finish floor shall protrude no more than 4 inches into the circulation path.  CH9 4.1.3(2) and 4.4.1        
288 Carnegie Hall Level One Offices (typical) The doors have knob hardware which requires twisting of the wrist to operate. Door hardware that does not require tight grasping, pinching or twisting of the wrist to operate is required.  CH11 through CH13 4.1.3(7)(b) and 4.13.9        
291 Carnegie Hall Level Two Mills College Annual Fund Room 229 The door has knob hardware which requires twisting of the wrist to operate. Door hardware that does not require tight grasping, pinching or twisting of the wrist to operate is required.  none 4.1.3(7)(b) and 4.13.9        
292 Carnegie Hall Level Two Offices (typical) A room number sign is not mounted on the wall adjacent to the latch side of the door. A sign mounted on the wall adjacent to the latch side of the door identifying the room number in raised characters and Braille is required. CH16 and CH17 4.1.3(16)(a), 4.30.1, 4.30.4, 4.30.5 and 4.30.6 Tactile characters on signs shall be located between 48 inches minimum and 60 inches maximum above the finish floor, measured to the baseline of the tactile character. 216.2, 703.1-5    
293 Lisser Hall Exterior Parking Lot E-2 The curb ramp projects into the access aisle of the designated accessible parking space in front of the annex. Accessible parking spaces and access aisle are required to be level with surface slopes not exceeding 1:50 (2%) in all directions.  LH1 and LH2 4.1.2(5)(a) and 4.6.3        
304 Lisser Hall First Floor Lobby The typical coffee bar counter is 42 inches above the finish floor. At least one coffee bar with a portion of the main counter which is a minimum of 36 inches long and a maximum of 36 inches high is required.  LH13 7.2(1)        
305 Lisser Hall First Floor Auditorium No wheelchair locations are provided. Four wheelchair locations are required. LH14 through LH16 4.1.3(19)(a), 4.33.2, 4.33.3 and 4.33.4 Five wheelchair locations are required. 221.2.1 and 802    
306 Lisser Hall First Floor Auditorium No aisle seats with movable armrest are provided. Three aisle seats with no armrests on the aisle side, or removable or folding armrests on the aisle side are required.  LH17 4.1.3(19)(a) At least 5 percent of the total number of aisle seats provided shall have folding or retractable armrests on the aisle side. 221.4 and 802.4    
307 Lisser Hall First Floor Auditorium Signage notifying patrons of the availability of an assistive listening system is not provided. A permanently installed assistive listening, eight receivers and signage notifying patrons of the availability of a listening system is required none 4.1.3(19)(b), 4.33.6, 4.33.7 and 4.30.7(4) An assistive listening system with 9 receivers, including 2 hearing-aid compatible receivers shall be provided. A sign informing patrons of the availability of the assistive listening system shall be provided.  216.10, 219, 703.5, 703.7.2.4 and 706    
308 Lisser Hall First Floor Vestibule The clear opening width of a single leaf of the double leaf door is 27 inches. The clear opening width of at least one leaf of the door is required to be 32 inches minimum measured between the face of the door and the opposite stop when the door is open 90 degrees.  LH18 4.1.3(7)(b), 4.13.4, 4.13.5 and Fig. 24(a)        
309 Lisser Hall First Floor Vestibule One standard height drinking fountain is provided. A drinking fountain accessible to individuals who use wheelchairs is required. LH19 4.1.3(10)(a) and 4.15        
310 Lisser Hall First Floor Vestibule The ticket counter is 42½ inches above the finish floor. A ticket counter with a portion of the main counter which is a minimum of 36 inches long and a maximum of 36 inches high is required.  LH20 7.2(1)        
311 Lisser Hall First Floor Men's and Women's Toilet Rooms The men's and women's toilet rooms are not accessible, and a directional sign to the designated accessible toilet room is not provided. A sign indicating the location of the designated accessible toilet room is required.  LH21 and LH22 4.1.6(3)(e)(iii)        
312 Lisser Hall First Floor Route to Unisex Toilet Room on Portico The clear opening width of a single leaf of the double leaf entrance door is 27 inches. The clear opening width of at least one leaf of the door is required to be 32 inches minimum measured between the face of the door and the opposite stop when the door is open 90 degrees.  LH23 4.1.3(8), 4.1.3(7)(b), 4.13.4, 4.13.5 and Fig. 24(a)        
315 Lisser Hall First Floor Unisex Toilet Room The toilet centerline is 20½ inches from the side wall. The toilet centerline is required to be exactly 18 inches from the side wall.  LH25 4.1.3(11), 4.22.4, 4.16.2 and Fig. 28 The centerline of the toilet shall be 16 inches minimum to 18 inches maximum from the side wall or partition. 213.3.2 and 604.2    
325 Mills Hall First Floor Women's Toilet Room - Room 131 Designated Accessible Toilet Stall The toilet seat is 16½ inches high. The toilet seat is required to be between 17 and 19 inches high.  MH8 4.1.3(11), 4.22.4, 4.17.2, 4.16.3 and Fig. 29(b)        
328 Mills Hall First Floor Women's Toilet Room - Room 131 The clearance at the lavatory apron is 27½ inches above the finish floor. Clearance at least 29 inches above the finish floor to the bottom of the apron is required.  MH9 4.1.3(11), 4.22.6 and 4.19.2 Lavatory knee clearance shall be 8 inches deep minimum at 27 inches minimum above the finish floor 213.3.4, 606.2 and 306.3    
330 Mills Hall First Floor Men's Toilet Room - Room 125 Designated Accessible Toilet Stall The toilet stall is 57 inches wide and 52 inches deep to the in‑swinging stall door. An accessible toilet stall with an in‑swinging door and a wall mounted toilet is required to provide a clear floor space that is a minimum of 60 inches wide and 56 inches deep.  MH11 4.1.3(11), 4.22.4, 4.17.3 and Fig. 30(a-1)        
333 Mills Hall First Floor Men's Toilet Room - Room 125  The clearance at the lavatory apron is 27½ inches above the finish floor. Clearance at least 29 inches above the finish floor to the bottom of the apron is required.  MH13 4.1.3(11), 4.22.6 and 4.19.2 Lavatory knee clearance shall be 8 inches deep minimum at 27 inches minimum above the finish floor 213.3.4, 606.2 and 306.3    
334 Mills Hall Second and Third Floors Corridor The clear opening width of the typical office and meeting room door is 29 inches. The clear opening width of a door is required to be 32 inches minimum measured between the face of the door and the opposite stop when the door is open 90 degrees.  MH14 and MH15 4.1.3(7)(b), 4.13.5 and Fig. 24(a)       Relocate classes and meetings to accessible rooms as required
335 Mills Hall Second and Third Floors Men's and Women's Toilet Rooms The men's and women's toilet room are not accessible, and a directional sign to the designated accessible men's and women's toilet rooms is not provided. A sign indicating the location of the designated accessible toilet rooms is required. MH17 through MH19 4.1.6(3)(e)(iii)        
336 Mills Hall Second and Third Floors Men's and Women's Toilet Rooms The force required to open the doors is 8 lbf. The maximum allowable force for opening an interior door is 5 lbf.  none 4.1.3(7)(b) and 4.13.11(2)(b)        
337 Mills Hall Second and Third Floors Men's and Women's Toilet Rooms The shelf in the designated accessible toilet stall protrudes 14½ inches from the wall and the leading edge is 41 inches above the finish floor. Objects mounted to walls with their leading edges between 27 inches and 80 inches above the finish floor shall protrude no more than 4 inches into the circulation path. MH20 and MH21 4.1.3(2) and 4.4.1        
339 Mills Hall Fourth Floor Guest Suite 413 Entrance The door has a chain security lock, which requires tight pinching to operate. Door hardware that does not require tight grasping, pinching or twisting of the wrist to operate is required.  MH22 9.1.2, 9.2.2(3) and 4.13.9        
340 Mills Hall Fourth Floor Guest Suite 413 Entrance The force required to open the door is 8 lbf. The maximum allowable force for opening an interior door is 5 lbf.  none 9.1.2, 9.2.2(3) and 4.13.11(2)(b)        
343 Mills Hall Fourth Floor Guest Suite 413 Kitchen The microwave control is higher than 54 inches above the finish floor. A microwave control that is no higher than 54 inches above the finish floor for a side reach is required.  MH25 and MH26 9.1.2, 9.2.2(7), 4.27.3, 4.2.6 and Fig. 6 A microwave with a control no higher than 48 inches above the finish floor for an unobstructed reach is required. 224.2, 806.2.5, 804.6, 309.3 and 308    
344 Mills Hall Fourth Floor Guest Suite 413 Kitchen The oven controls require tight grasping and twisting of the wrist to operate. Controls which do not require tight grasping, tight pinching or twisting of the wrist to operate are required.  MH25 and MH26 9.1.2, 9.2.2(7) and 4.27.4        
345 Mills Hall Fourth Floor Guest Suite 413 Bedroom The clear opening width of the walk-in closet door is 25½ inches. The clear opening width of the door is required to be 32 inches minimum measured between the face of the door and the opposite stop when the door is open 90 degrees.  MH27 9.1.2, 9.2.2(3) and 4.13.5        
346 Mills Hall Fourth Floor Guest Suite 413 Bedroom The closet rod is 69 inches above the finish floor. A closet rod that is a maximum of 54 inches above the finish floor for a side reach is required.  MH27 9.1.2, 9.2.2(4), 4.25.3, 4.2.6 and Fig. 6 A rod no higher than 46 inches above the finish floor for an obstructed side reach is required. 222.2, 803.5 and 308    
347 Mills Hall Fourth Floor Guest Suite 413 Bedroom The closet shelf is 71 inches above the finish floor. A closet shelf that is a maximum of 54 inches above the finish floor for a side reach is required.  MH27 9.1.2, 9.2.2(4), 4.25.3, 4.2.6 and Fig. 6 A shelf no higher than 46 inches above the finish floor for an obstructed side reach is required. 222.2, 803.5 and 308    
348 Mills Hall Fourth Floor Guest Suite 413 Bathroom The pocket door hardware requires tight pinching and twisting of the wrist to operate. Door hardware that does not require tight grasping, pinching or twisting of the wrist to operate is required.  MH28 and MH29 9.1.2, 9.2.2(3) and 4.13.9        
350 Mills Hall Fourth Floor Guest Suite 413 Bathroom A bathtub seat is not provided. A securely mounted bathtub seat is required.  MH31 9.1.2, 9.2.2(6)(e), 4.23.8, 4.20.3 and Fig. 33        
351 Mills Hall Fourth Floor Guest Suite 413 Bathroom The bathtub faucet has knob controls. Controls which do not require tight grasping, tight pinching or twisting of the wrist to operate are required.  MH32 9.1.2, 9.2.2(6)(e), 4.23.8, 4.20.5 and 4.27.4        
352 Mills Hall Fourth Floor Guest Suite 413 Bathroom The bathtub controls are located in the center of the control wall. Offset bathtub controls, which are located between the open edge and the midpoint of the tub are required.  MH32 9.1.2, 9.2.2(6)(e), 4.23.8 and 4.20.5        
358 Reinhardt Alumnae House Entrance Door A ½-inch vertical change in level is located at the threshold. A change in level that is no higher than ¼ inch vertical or ½ inch beveled with a slope no greater than 1:2 is required.  RAH4 4.1.2(1), 4.1.3(8), 4.3.8 and 4.5.2        
361 Reinhardt Alumnae House Interior Toilet Room Corridor The clear opening width of the door is 31½ inches. The clear opening width of the door is required to be 32 inches minimum measured between the face of the door and the opposite stop when the door is open 90 degrees.  RAH6 4.1.3(7)(b), 4.13.5 and Fig. 24(a)        
362 Reinhardt Alumnae House Interior Women's Toilet Room The women's toilet room is not accessible, and a directional sign to the designated accessible toilet room is not provided. A sign indicating the location of the designated accessible toilet room is required.  RAH7 4.1.6(3)(e)(iii)        
363 Reinhardt Alumnae House Interior Unisex Toilet Room The toilet room sign is mounted more than 60 inches above the finish floor to the centerline of the sign. A permanent room sign mounted at 60 inches above the finish floor to the centerline of the sign is required.  RAH7 4.1.3(16)(a) and 4.30.6 Tactile characters on signs shall be located between 48 inches minimum and 60 inches maximum above the finish floor, measured to the baseline of the tactile character. 216.2, 703.1-5    
364 Reinhardt Alumnae House Interior Unisex Toilet Room The toilet room sign is mounted more than 60 inches above the finish floor to the centerline of the sign. A permanent room sign mounted at 60 inches above the finish floor to the centerline of the sign is required.  RAH8 4.1.3(16)(a) and 4.30.6 Tactile characters on signs shall be located between 48 inches minimum and 60 inches maximum above the finish floor, measured to the baseline of the tactile character. 216.2, 703.1-5    
365 Reinhardt Alumnae House Interior Unisex Toilet Room The force required to open the toilet room door is 10 lbf. The maximum allowable force for opening an interior door is 5 lbf.  none 4.1.3(7)(b) and 4.13.11(2)(b)        
367 Reinhardt Alumnae House Interior Unisex Toilet Room The rear toilet grab bar is 24 inches long. A 36-inch long rear grab bar is required.  RAH10 4.1.3(11), 4.22.4, 4.16.4 and Fig. 29(a)        
368 Reinhardt Alumnae House Interior Unisex Toilet Room The space between the wall and the rear grab bar is 2 inches. The space between the wall and the grab bar shall be exactly 1½ inches.  RAH10 4.1.3(11), 4.22.4, 4.16.4, 4.26.2 and Fig. 39(e)