ATTACHMENT K: Modifications to Altered FacilitiesThe technical requirements and, where appropriate, the scoping requirements of the Standards are used as a guide for determining whether a program or activity held in an existing facility is “readily accessible to and usable by” persons with disabilities and for determining what changes are necessary to make this program or activity accessible if it continues to be provided in the existing facility in question. See 28 C.F.R. §§ 35.150(b)(1), 35.151. The chart below lists the facilities surveyed by the Department, the access issues identified during the survey, and the actions required to correct the access issues. Required actions are listed using an alphanumeric code. The key to the alphanumeric codes is provided in Attachment M to this Agreement. In order to ensure that the programs, services, and activities housed in the County’s facilities are accessible to persons with disabilities, when viewed in their entirety, the County will take the actions referenced by the alphanumeric code and described in detail in Attachment M to this Settlement Agreement within the time period specified below, which time period begins to run on the effective date of the Agreement. | |||
Item # | Access Issue | Remedial Code | Completion Date |
---|---|---|---|
1. | WINTON PARK, located at Olive Ave and Winton Way, Winton | ||
1.1. | Route to picnic pavilion. The route to the picnic pavilion is inaccessible because the surface is not level. | AR1 | 2.5 years |
1.2. | Concession Counter. The counter is inaccessible because it is 41 inches high. | C1 | 2.5 years |
1.3. | Picnic Tables. The picnic tables in the park are inaccessible because none provide the required knee space. | DW1 | 6 months |
1.4. | Route to toilet rooms near pavilion. The route is inaccessible because the grass is not firm, stable, and slip resistant. | AR1 | 2.5 years |
1.5. | Route to volleyball court and horseshoe pit. The route is inaccessible because the grass is not firm, stable, and slip resistant. | AR1 | 2.5 years |
1.6. | Route to soccer field, basketball court, and baseball field. The route to the soccer field, basketball court, and baseball field is inaccessible because the change in level at the curb is 5 inches and the grass is not firm, stable, and slip resistant. | AR1 | 2.5 years |
1.7. | Route to Port-A-Potty. The route to the port-a-potty is inaccessible because the change in level at the curb is more than 4 inches and the grass is not firm, stable, and slip resistant. | AR1 | 2.5 years |
1.8. | Route to park amenities. The route to the play area, picnic tables, grill, and toilet rooms next to the ballfield is inaccessible because the change in level at the curb is more than 5 inches and the grass is not firm, stable, and slip resistant. | AR1 | 2.5 years |
1.9. | Women's and Men's Toilet Rooms near baseball field. The women's and men's toilet rooms contain a number of inaccessible elements and are not accessible to people with disabilities. | TR26 | 2.5 years |
1.10. | Drinking fountain next to ballfield. The drinking fountain between the toilet rooms protrudes into the walkway and is not detectable to blind persons using a cane. | AR7 | 6 months |
1.11. | Route to Concession Counter near ballfield. The route to the concession counter is inaccessible because the change in level at the curb is more than 3 inches and the grass is not firm, stable, and slip resistant. | AR1 | 2.5 years |
1.12. | Concession Counter. The counter is inaccessible because it is 39 inches high. | C1 | 2.5 years |
2. | F D BALLICO PARK, located at 11892 Grove Street | ||
2.1. | Route to Dugout. The route is inaccessible because the sand is not firm, stable, and slip resistant. | AR1 | 2.5 years |
2.2. | Concession Counter. The counter is inaccessible because it is more than 37 inches high. | C1 | 2.5 years |
2.3. | Drinking fountain near concession counter. The drinking fountain is inaccessible because it has a spout that is 31 inches high and it provides 25 inches of clear knee height. | DF1 | 2.5 years |
2.4. | Route to picnic tables, play area, and drinking fountain in play area. The route is inaccessible because the grass is not firm, stable, and slip resistant. | AR1 | 2.5 years |
2.5. | Picnic Tables. The picnic tables are inaccessible because none provide the required knee space. | DW1 | 6 months |
2.6. | Drinking Fountain: None of the drinking fountains provided is accessible. | DF1 | 2.5 years |
2.7. | Ramp to Play Area: The ramp is inaccessible because it has a slope of up to 10.1%. | R4 | 2.5 years |
2.8. | Men's Single-User Toilet Room: The toilet room contains a number of inaccessible elements and is not accessible to people with disabilities. | TR26 | 2.5 years |
2.9. | Women's Single-User Toilet Room: The toilet room contains a number of inaccessible elements and is not accessible to people with disabilities. | TR26 | 2.5 years |
2.10. | Women's Toilet Room: | ||
2.10.a. | The centerline of the toilet in the compartment for persons with disabilities is 20 inches from the side wall. | TR7 | 2.5 years |
2.10.b. | The toilet paper dispenser does not allow for the continuous flow of toilet paper. | TR6 | 6 months |
2.11. | Playground: | ||
2.11.a. | The elevated pay structure designed for younger children does not have a transfer area. | PG1 | 2.5 years |
2.11.b. | No accessible route is provided to the swing set. | AR1 | 2.5 years |
3. | MERCED COUNTY SHERIFF'S OFFICE/MAIN JAIL, located at 700 w. 22nd St. | ||
3.1. | Corrections Records Unit (Employee Area): The door is inaccessible because knob hardware is used. | D2 | 6 months |
3.2. | Men's Trustee Toilet Room with Shower: | ||
3.2.a. | None of the mirrors provided is accessible. | TR5 | 6 months |
3.2.b. | The toilet is inaccessible because the rear grab bar is obstructed by the toilet flush valve. | TR15 | 6 months |
3.2.c. | The transfer shower is inaccessible because no transfer seat has been provided. | B6 | 6 months |
3.3. | Men's Property Toilet Room with Shower: | ||
3.3.a. | None of the mirrors provided is accessible. | TR5 | 6 months |
3.3.b. | The toilet is inaccessible because the rear grab bar is obstructed by the toilet flush control unit. | TR15 | 6 months |
3.4. | Visitation Area (Inmate Side): The visitation area is inaccessible because no accessible seating has been provided. | PJ4 | 6 months |
3.5. | Intake/Administration: The route at the top of the ramp by the finger print machine is inaccessible because the width is 31 inches. | AR3 | 6 months |
4. | LOS BANOS FAIRGROUNDS, located at 403 F St. | ||
4.1. | Administrative Office: The counter is inaccessible because it is 41 3/4 inches high. | C1 | 6 months |
4.2. | O'Banion Auditorium Women's Toilet Room with Stalls (Lobby): | ||
4.2.a. | The toilet room sign is mounted on the hinge side of the door. | TR11 | 6 months |
4.2.b. | The paper towel protrudes into the walkway and is not detectable to blind persons using a cane. | AR7 | 6 months |
4.2.c. | The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact. | LS2 | 6 months |
4.2.d. | The lavatory is inaccessible because it has twist-type hardware. | LS4 | 6 months |
4.2.e. | The designated accessible toilet stall is inaccessible because it is 58 inches long and 55 inches wide. | TR23 | 6 months |
4.2.f. | The designated accessible toilet is inaccessible because there is insufficient clear floor space. | TR24 | 6 months |
4.2.g. | The side grab bar at the designated accessible toilet is inaccessible because the far end is mounted 49 1/2 inches from the rear wall. | TR17 | 6 months |
4.3. | O'Banion Auditorium Men's Toilet Room with Stalls (Lobby): | ||
4.3.a. | The toilet room sign is mounted on the hinge side of the door. | TR11 | 6 months |
4.3.b. | None of the mirrors provided is accessible. | TR5 | 6 months |
4.3.c. | The toilet seat cover dispenser is inaccessible because it is mounted 63 inches high behind the toilet. | CT3 | 6 months |
4.3.d. | The paper towel protrudes into the walkway and is not detectable to blind persons using a cane. | AR7 | 6 months |
4.3.e. | The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact. | LS2 | 6 months |
4.3.f. | The designated accessible toilet stall is inaccessible because it is 59 inches long and 56 inches wide. | TR23 | 6 months |
4.3.g. | The designated accessible toilet is inaccessible because the top of the seat is 15 inches high. | TR9 | 6 months |
4.3.h. | The side grab bar at the designated accessible toilet is inaccessible because the far end is mounted 50 inches from the rear wall. | TR17 | 6 months |
4.3.i. | The designated accessible toilet is inaccessible because the rear grab bar is mounted 7 inches from the side wall. | TR13 | 6 months |
4.4. | O'Banion Auditorium (Near Entrance): | ||
4.4.a. | Route to Stage: There is no accessible route connecting the wheelchair seating areas and the stage. | AA1 | 6 months |
4.5. | Men's Locker Room (Rear of Auditorium): | ||
4.5.a. | The toilet room is inaccessible because there is insufficient turning space provided within the room | TR21 | 6 months |
4.5.b. | The toilet seat cover dispenser is inaccessible because it is mounted 36 inches high behind the toilet. | CT3 | 6 months |
4.5.c. | The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact. | LS2 | 6 months |
4.5.d. | The lavatory is inaccessible because its clear floor space 41 inches deep. | LS5 | 6 months |
4.5.e. | There is no accessible shower provided. | B2 | 6 months |
4.6. | Women's Locker Room (Rear of Auditorium): | ||
4.6.a. | The toilet room is inaccessible because there is insufficient turning space provided within the room | TR21 | 6 months |
4.6.b. | The toilet seat cover dispenser is inaccessible because it is mounted 41 inches high behind the toilet. | CT3 | 6 months |
4.6.c. | The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact. | LS2 | 6 months |
4.6.d. | The designated accessible toilet stall is inaccessible because it is 57 inches long and 58 inches wide. | TR23 | 6 months |
4.6.e. | The designated accessible toilet is inaccessible because the flush control is on the closed side. | TR4 | 6 months |
4.6.f. | There is no accessible shower provided. | B2 | 6 months |
4.7. | Exhibit Building: The exhibit floor is inaccessible to people with hearing disabilities because there is no assistive listening system provided. | AA4 | 6 months |
4.8. | Women Toilet Rooms with Stalls (Exhibit Building): | ||
4.8.a. | The toilet room sign is not mounted on the latch side of the door. | TR11 | 6 months |
4.8.b. | The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact. | LS2 | 6 months |
4.8.c. | The designated accessible toilet is inaccessible because the top of the seat is 19 1/2 inches high. | TR9 | 6 months |
4.8.d. | The designated accessible toilet is inaccessible because the flush control is on the closed side. | TR4 | 6 months |
4.9. | Men Toilet Rooms with Stalls (Exhibit Building): | ||
4.9.a. | The toilet room sign is not mounted on the latch side of the door. | TR11 | 6 months |
4.9.b. | None of the mirrors provided is accessible. | TR5 | 6 months |
4.9.c. | The paper towel dispenser is inaccessible because it is mounted with the controls 61 inches high. | CT4 | 6 months |
4.9.d. | The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact. | LS2 | 6 months |
4.9.e. | The urinal is inaccessible because the rim is 24 inches high and the flush control is 45 inches high. | TR8 | 6 months |
4.9.f. | The designated accessible toilet stall is inaccessible because it is 56 inches wide. | TR23 | 6 months |
4.9.g. | The designated accessible toilet is inaccessible because the flush control is on the closed side. | TR4 | 6 months |
4.10. | Unisex Single-User Toilet Room in Concession Stand (Exhibit Building): | ||
4.10.a. | The toilet room sign is not mounted on the latch side of the door. | TR11 | 6 months |
4.10.b. | The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact. | LS2 | 6 months |
4.11. | Floral Building: The exhibit floor is inaccessible to people with hearing disabilities because there is no assistive listening system provided. | AA4 | 6 months |
4.12. | Germino Building: The exhibit floor is inaccessible to people with hearing disabilities because there is no assistive listening system provided. | AA4 | 6 months |
4.13. | Men's Single-User Toilet Room (Germino Building): | ||
4.13.a. | The door is inaccessible because it requires 6 pounds of force to open. | D3 | 6 months |
4.13.b. | The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact. | LS2 | 6 months |
4.13.c. | The toilet is inaccessible because the flush control is on the closed side | TR4 | 6 months |
4.14. | Women's Single-User Toilet Room (Germino Building): | ||
4.14.a. | The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact. | LS2 | 6 months |
4.15. | Drinking Fountain (Germino Building): | ||
4.15.a. | The drinking fountain is inaccessible because the controls require more than 5 pounds of force to operate. | DF2 | 6 months |
4.15.b. | Although a designated accessible drinking fountain is provided, there is no drinking fountain provided for people who have difficulty bending or stooping. | DF3 | 6 months |
4.16. | Outdoor Stage: | ||
4.16.a. | The route to the outdoor stage seating area is inaccessible because the grass is not firm, stable, and slip resistant. | AR1 | 6 months |
4.16.b. | The outdoor stage seating area is inaccessible because no wheelchair seating areas are provided. | AA6 | 6 months |
4.16.c. | There is no accessible route connecting the wheelchair seating areas and the stage. | AA1 | 6 months |
4.17. | Men's Toilet Room with Stalls (Near Outdoor Stage): | ||
4.17.a. | No accessible toilet room sign has been provided. | TR11 | 6 months |
4.17.b. | The door is inaccessible because knob hardware is used. | D2 | 6 months |
4.17.c. | The toilet room door swings into the required clear floor space at the lavatory. | TR12 | 6 months |
4.17.d. | The toilet seat cover dispenser is inaccessible because it is mounted 60 inches high behind the toilet. | CT3 | 6 months |
4.17.e. | The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact. | LS2 | 6 months |
4.17.f. | The designated accessible toilet stall is inaccessible because it is 54 inches wide. | TR23 | 6 months |
4.17.g. | The designated accessible toilet is inaccessible because the top of the seat is 16 inches high. | TR9 | 6 months |
4.17.h. | The designated accessible toilet is inaccessible because the flush control is on the closed side. | TR4 | 6 months |
4.17.i. | The side grab bar at the designated accessible toilet is inaccessible because it farther end is 48 inches from the rear wall. | TR17 | 6 months |
4.18. | Women's Toilet Room with Stalls (Near Outdoor Stage): | ||
4.18.a. | No accessible toilet room sign has been provided. | TR11 | 6 months |
4.18.b. | The door is inaccessible because knob hardware is used. | D2 | 6 months |
4.18.c. | The toilet room door swings into the required clear floor space at the toilet stall. | TR12 | 6 months |
4.18.d. | The toilet seat cover dispenser is inaccessible because it is mounted 64 inches high behind the toilet. | CT3 | 6 months |
4.18.e. | The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact. | LS2 | 6 months |
4.18.f. | The designated accessible toilet is inaccessible because the top of the seat is 16 1/2 inches high. | TR9 | 6 months |
4.18.g. | The route to the bar behind the pavilion is inaccessible because the dirt and grass is not firm, stable, and slip resistant. | AR1 | 6 months |
4.18.h. | The bar behind the pavilion is inaccessible because it is 41 1/2 inches high. | C1 | 6 months |
4.19. | Women's Toilet Room with Stalls (Near Livestock Exhibits): | ||
4.19.a. | The toilet room sign is not mounted on the latch side of the door and has no raised or Braille characters. | TR11 | 6 months |
4.19.b. | The paper towel dispenser protrudes into the walkway and is not detectable to blind persons using a cane. | AR7 | 6 months |
4.19.c. | The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact. | LS2 | 6 months |
4.19.d. | The designated accessible toilet is inaccessible because the top of the seat is 16 inches high. | TR9 | 6 months |
4.19.e. | The designated accessible toilet is inaccessible because the flush control is on the closed side. | TR4 | 6 months |
4.20. | Men's Toilet Room with Stalls (Near Livestock Exhibits): | ||
4.20.a. | The toilet room sign is not mounted on the latch side of the door and has no raised or Braille characters. | TR11 | 6 months |
4.20.b. | The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact. | LS2 | 6 months |
4.20.c. | The lavatory is inaccessible because the hardware is missing. | LS4 | 6 months |
4.20.d. | The designated accessible toilet is inaccessible because the flush control is on the closed side. | TR4 | 6 months |
4.21. | Judging Arena: The arena is inaccessible because no wheelchair seating areas are provided. | AA6 | 6 months |
4.22. | Arburua Arena: | ||
4.22.a. | There is no accessible route connecting the wheelchair seating areas and the arena floor. | AA1 | 6 months |
4.22.b. | The arena floor is inaccessible to people with hearing disabilities because there is no assistive listening system provided. | AA4 | 6 months |
4.23. | Carousel Arena: The arena floor is inaccessible to people with hearing disabilities because there is no assistive listening system provided. | AA4 | 6 months |
4.24. | Route to Barn Concessions: The route is inaccessible because the grass is not firm, stable, and slip resistant. | AR1 | 6 months |
4.25. | Women's Toilet Room with Stalls (Outside Motor Cross Gates): | ||
4.25.a. | The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact. | LS2 | 6 months |
4.26. | Men's Toilet Room with Stalls (Outside Motor Cross Gates): | ||
4.26.a. | The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact. | LS2 | 6 months |
4.26.b. | The designated accessible toilet is inaccessible because the side grab bar is obstructed by the toilet paper dispenser. | TR15 | 6 months |
4.27. | Women's Toilet Room with Stalls (Inside Motor Cross Gates): | ||
4.27.a. | The toilet room sign is not mounted on the latch side of the door. | TR11 | 6 months |
4.27.b. | The toilet seat cover dispenser is inaccessible because it is mounted 48 inches high behind the toilet. | CT3 | 6 months |
4.27.c. | No accessible coat hook has been provided. | TR3 | 6 months |
4.28. | Men's Toilet Room with Stalls (Inside Motor Cross Gates): | ||
4.28.a. | The toilet room sign is not mounted on the latch side of the door. | TR11 | 6 months |
4.28.b. | The toilet seat cover dispenser is inaccessible because it is mounted 49 inches high behind the toilet. | CT3 | 6 months |
4.28.c. | No accessible coat hook has been provided. | TR3 | 6 months |
4.28.d. | The designated accessible toilet is inaccessible because the side grab bar is obstructed by the toilet paper dispenser. | TR15 | 6 months |
4.29. | Ramp to Bleachers: | ||
4.29.a. | The ramp is inaccessible because it has a slope of up to 9.7%. | R4 | 6 months |
4.29.b. | The ramp is inaccessible because it does not have edge protection at the drop off sides. | R3 | 6 months |
4.29.c. | The ramp is inaccessible because the ends of the handrails are not rounded or returned and the inside handrail is mounted 2 inches from the wall. | R2 | 6 months |
4.30. | Motocross Arena: The outdoor arena is inaccessible to people with hearing disabilities because there is no assistive listening system provided. | AA4 | 6 months |
4.31. | Parking Lots: The two parking lots, with a total of 331 parking spaces, are inaccessible because there is no designated van accessible space provided, no vertical signage, and only one of the designated accessible spaces provided has an access aisle. This lot requires 1 van accessible space and 7 standard accessible spaces. | P1 | 6 months |
4.32. | Accessible Route: The route from the parking lots to the Motocross Arena is inaccessible because there is no curb cut provided. | AR4 | 6 months |
5. | Los Banos Library, located at 1312 S. 7th Street | ||
5.1. | Route to Library: The route to the library is inaccessible because there is a 1 inch change in level at the top of the curb cut. | AR1 | 6 months |
5.2. | Ramp: The ramp is inaccessible because the handrail extensions are not placed over the level landing at the bottom, and it has a slope greater than 8.33% at the top. | R2 | 6 months |
5.3. | Exterior Doors: The double doors are inaccessible because each leaf is 29 1/2 inches wide. | D13 | 6 months |
5.4. | Library: | ||
5.4.a. | The check-out area is inaccessible because the counter is 39 inches high. | C1 | 6 months |
5.4.b. | The computer table is inaccessible because it provides 25 1/2 inches of clear knee height. | C2 | 6 months |
5.5. | Drinking Fountains (Near Toilet Rooms): The drinking fountain protrudes into the walkway and is not detectable to blind persons using a cane. | AR7 | 6 months |
5.6. | Unisex Single-User Toilet Room (Near Drinking Fountains): | ||
5.6.a. | The toilet room sign is not mounted on the latch side of the door and lacks the International Symbol of access. | TR11 | 6 months |
5.6.b. | The door is inaccessible because it requires 9 pounds of force to open. | D3 | 6 months |
5.6.c. | None of the mirrors provided is accessible. | TR5 | 6 months |
6. | Shattuck Educational Center, located at 10082 Vincent Road | ||
6.1. | Parking Lot: The parking lot, with a total of 30 parking spaces, is inaccessible because it has one space designated as accessible. This lot requires one van accessible space and one standard accessible space. | P5 | 6 months |
6.2. | Reception Counter: The counter is inaccessible because it is 43 1/2 inches high. | C1 | 6 months |
6.3. | Tables (Near Basketball Court): | ||
6.3.a. | The route to the tables is inaccessible because the surface is not is firm, stable, and slip resistant | AR1 | 6 months |
6.3.b. | The tables are inaccessible because they provide less than 27 inches of clear knee height. | DW1 | 6 months |
6.4. | Unisex Single-User Toilet Room (Students): | ||
6.4.a. | The toilet room sign is not mounted on the latch side of the door. | TR11 | 6 months |
6.4.b. | Although an audible alarm is provided in this facility, there is no visual alarm appliance in the toilet room. | AL1 | 6 months |
6.4.c. | No accessible coat hook has been provided. | TR3 | 6 months |
6.4.d. | None of the mirrors provided is accessible. | TR5 | 6 months |
6.4.e. | The toilet is inaccessible because the side grab bar is mounted with its far end 45 inches from the rear wall. | TR16 | 6 months |
6.5. | Drinking Fountain (Inside Near Employee Area): Although a designated accessible drinking fountain is provided, there is no drinking fountain provided for people who have difficulty bending or stooping. | DF3 | 6 months |
7. | Workforce Investment, located at 1880 Wardrobe Avenue | ||
7.1. | Women's Toilet Room with Stall: | ||
7.1.a. | The paper towel dispenser protrudes into the walkway and is not detectable to blind persons using a cane. | AR7 | 6 months |
7.1.b. | The sanitary napkin dispenser is inaccessible because the controls require twisting of the wrist to operate. | CT2 | 6 months |
7.1.c. | The lavatory is inaccessible because it does not provide adequate knee and toe clearance. | LS3 | 6 months |
7.1.d. | The designated accessible toilet is inaccessible because the top of the seat is 16 inches high. | TR9 | 6 months |
7.1.e. | The designated accessible toilet is inaccessible because its centerline is 14 inches from the side wall. | TR7 | 6 months |
7.2. | Men's Toilet Room with Stall: | ||
7.2.a. | The lavatory is inaccessible because it does not provide adequate knee and toe clearance. | LS3 | 6 months |
7.2.b. | The urinal is inaccessible because the rim is 24 inches high, the depth of the clear floor space is 29 inches, and the flush control is more than 44 inches high. | TR8 | 6 months |
8. | Human Services Agency, located at 2115 Wardrobe Avenue | ||
8.1. | Interview Room (Main Building): Many of the tables in the interview rooms are inaccessible because they provide 26 1/2 inches of clear knee height. | DW1 | 2.5 years |
8.2. | Drinking Fountains (Main Building): The drinking fountains are inaccessible because the knee space height is 25 inches. | DF4 | 2.5 years |
8.3. | Women's Toilet Room with Stall (Main Building): | ||
8.3.a. | The sanitary napkin dispenser is inaccessible because the controls require twisting of the wrist to operate. | CT2 | 2.5 years |
8.3.b. | The designated accessible toilet is inaccessible because the flush control is on the closed side. | TR4 | 2.5 years |
8.3.c. | The designated accessible toilet is inaccessible because the top of the seat is 22 inches high. | TR9 | 2.5 years |
8.3.d. | The designated accessible toilet is inaccessible because the flush control is on the closed side. | TR4 | 2.5 years |
8.4. | Women's Toilet Room with Stall (Employment & Training Bldg): | ||
8.4.a. | The toilet room sign is not mounted on the latch side of the door. | TR11 | 6 months |
8.4.b. | The sanitary napkin dispenser is inaccessible because the controls require twisting of the wrist to operate. | CT2 | 6 months |
8.4.c. | The sanitary napkin dispenser protrudes into the walkway and is not detectable to blind persons using a cane. | AR7 | 6 months |
8.5. | Men's Toilet Room with Stall (Employment & Training Bldg): The toilet room sign is not mounted on the latch side of the door. | TR11 | 6 months |
8.6. | Interview Rooms (Employment & Training Bldg): Many of the doors to the interview rooms are inaccessible because they require more than 5 pounds of force to open. | D3 | 6 months |
8.7. | Training Room 105A-105B (Employment & Training Bldg): The computer table is inaccessible because it provides 26 1/2 inches of clear knee height. | C2 | 2.5 years |
8.8. | Drinking Fountain by Orientation Program Area (Cafeteria Bldg): | ||
8.8.a. | The drinking fountain protrudes into the walkway and is not detectable to blind persons using a cane. | AR7 | 2.5 years |
8.8.b. | The drinking fountain is inaccessible because it has a spout that is 33 1/2 inches high and the knee space height is 24 inches. | DF1 | 2.5 years |
8.9. | Cafeteria (Cafeteria Bldg): The plastic utensils dispenser is inaccessible because it is mounted 67 inches high. | CT4 | 6 months |
8.10. | Women's Toilet Room with Stall (Cafeteria Bldg): | ||
8.10.a. | The sanitary napkin dispenser is inaccessible because the controls require twisting of the wrist to operate. | CT2 | 6 months |
8.10.b. | The designated accessible toilet is inaccessible because the flush control is on the closed side. | TR4 | 6 months |
8.11. | Men's Toilet Room with Stall (Cafeteria Bldg): The air dryer protrudes into the walkway and is not detectable to blind persons using a cane. | AR7 | 6 months |
8.12. | Parking Lot (Rear of Employment & Training Bldg Rear): The parking lot is inaccessible because there is a built-up curb ramp in the access aisle. | P2 | 2.5 years |
8.13. | Parking Lot (Front of Employment & Training Bldg): The parking lot is inaccessible because there is a built-up curb ramp in the access aisle. | P2 | 2.5 years |
9. | Planada Community Recreation Bldg (Polling), located at 9167 E. Stanford Avenue | ||
9.1. | Parking Lot: The parking lot, with a total of 31 parking spaces, is inaccessible because there is no additional van accessible signage provided for the designated van accessible space. This lot requires one van accessible space and one standard accessible space. | P5 | 2.5 years |
9.2. | Exterior Entrance: The building does not have directional signage posted at inaccessible entrances and does not have the International Symbol of Accessibility posted at accessible entrances. | D10 | 2.5 years |
9.3. | Interior Entrance: | ||
9.3.a. | The door is inaccessible because it has an opening width of 31 inches. | D14 | 6 months |
9.3.b. | The door is inaccessible because knob hardware is used. | D2 | 6 months |
9.4. | Route to Play Equipment and Park Benches: The route is inaccessible because the grass is not firm, stable, and slip resistant. | AR1 | 2.5 years |
9.5. | Route to Park Amenities: The route is inaccessible because the grass is not firm, stable, and slip resistant. | AR1 | 2.5 years |
9.6. | Drinking Fountain: | ||
9.6.a. | The route to the drinking fountain is inaccessible because the grass is not firm, stable, and slip resistant. | AR1 | 2.5 years |
9.6.b. | The drinking fountain is inaccessible because it has a spout that is 39 inches high. | DF3 | 2.5 years |
9.6.c. | The drinking fountain protrudes into the walkway and is not detectable to blind persons using a cane. | AR7 | 2.5 years |
9.7. | Outdoor Men's Toilet Room with Stall: | ||
9.7.a. | The route to the toilet room is inaccessible because there is a 1 1/2 inch change in level. | AR1 | 2.5 years |
9.7.b. | The toilet room door is inaccessible because it has an opening width of 29 inches. | D14 | 2.5 years |
9.7.c. | The toilet room contains a number of inaccessible elements and is not accessible to people with disabilities. | TR1 | 2.5 years |
9.8. | Outdoor Women's Toilet Room with Stall: | ||
9.8.a. | The route to the toilet room is inaccessible because there is a 1 1/2 inch change in level. | AR1 | 2.5 years |
9.8.b. | The toilet room door is inaccessible because it has an opening width of 29 inches. | D14 | 2.5 years |
9.8.c. | The toilet room contains a number of inaccessible elements and is not accessible to people with disabilities. | TR1 | 2.5 years |
9.9. | Indoor Women's Toilet Room with Stall: | ||
9.9.a. | The toilet room sign is not mounted on the latch side of the door and has no raised or Braille characters. | TR11 | 2.5 years |
9.9.b. | The door is inaccessible because it requires 8 pounds of force to open. | D3 | 2.5 years |
9.9.c. | The toilet room is inaccessible because there is insufficient turning space provided within the room. | TR21 | 2.5 years |
9.9.d. | The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact. | LS2 | 2.5 years |
9.9.e. | The designated accessible toilet stall is inaccessible because it is 49 inches wide. | TR23 | 2.5 years |
9.9.f. | The designated accessible toilet is inaccessible because the side grab bar is obstructed by the toilet paper dispenser. | TR15 | 2.5 years |
9.10. | Indoor Men's Toilet Room with Stall: | ||
9.10.a. | The toilet room sign is not mounted on the latch side of the door and has no raised or Braille characters. | TR11 | 2.5 years |
9.10.b. | The door is inaccessible because it requires 8 pounds of force to open. | D3 | 2.5 years |
9.10.c. | The toilet room is inaccessible because there is insufficient turning space provided within the room. | TR21 | 2.5 years |
9.10.d. | The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact. | LS2 | 2.5 years |
9.10.e. | The urinal is inaccessible because the rim is 25 inches high and the flush control is 52 inches high. | TR8 | 2.5 years |
9.10.f. | The designated accessible toilet stall is inaccessible because it is 49 inches wide. | TR23 | 2.5 years |
9.10.g. | The designated accessible toilet is inaccessible because the side grab bar is obstructed by the toilet paper dispenser. | TR15 | 2.5 years |
10. | Merced County Library, located at 1554 Golden Gate Avenue, Dos Palos | ||
10.1. | Exterior Entrance: | ||
10.1.a. | The building does not have directional signage posted at inaccessible entrances and does not have the International Symbol of Accessibility posted at accessible entrances. | D10 | 6 months |
10.1.b. | The door is inaccessible because there is a 1/3 inch high threshold. | D12 | 6 months |
10.1.c. | The door is inaccessible because knob hardware is used. | D2 | 6 months |
10.2. | Library: | ||
10.2.a. | The check-out counter is inaccessible because it is 42 inches high. | C1 | 2.5 years |
10.2.b. | The computer table is inaccessible because it provides 25 inches of clear knee height. | C2 | 6 months |
10.3. | Men's Toilet Room with Stall: | ||
10.3.a. | The toilet room sign is not mounted on the latch side of the door and has no raised or Braille characters. | TR11 | 6 months |
10.3.b. | The door is inaccessible because it has an opening width of 25 1/2 inches. | D14 | 2.5 years |
10.3.c. | The door is inaccessible because it requires 10 pounds of force to open. | D3 | 6 months |
10.3.d. | The pull side of the door, which is accessed through a front approach, is inaccessible because the clear space on the latch side is not adequate. | D5 | 2.5 years |
10.3.e. | The route to the toilet room is inaccessible because it lacks adequate turning space. | AR1 | 2.5 years |
10.3.f. | None of the mirrors provided is accessible. | TR5 | 6 months |
10.3.g. | The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact. | LS2 | 6 months |
10.3.h. | The lavatory is inaccessible because it has twist-type hardware. | LS4 | 6 months |
10.3.i. | The urinal is inaccessible because the rim is 24 inches high. | TR8 | 6 months |
10.3.j. | The designated accessible toilet stall is inaccessible because it is 60 inches long and 33 inches wide. | TR23 | 2.5 years |
10.3.k. | The designated accessible toilet is inaccessible because the top of the seat is 16 inches high. | TR9 | 6 months |
10.3.l. | The designated accessible toilet is inaccessible because its centerline is 19 1/2 inches from the side wall. | TR7 | 6 months |
10.3.m. | There are no grab bars provided at the designated accessible toilet. | TR18 | 6 months |
10.4. | Women's Toilet Room with Stall: | ||
10.4.a. | The toilet room sign is not mounted on the latch side of the door and has no raised or Braille characters. | TR11 | 6 months |
10.4.b. | The door is inaccessible because it has an opening width of 25 1/2 inches. | D14 | 2.5 years |
10.4.c. | The door is inaccessible because it requires 10 pounds of force to open. | D3 | 6 months |
10.4.d. | The pull side of the door, which is accessed through a front approach, is inaccessible because the clear space on the latch side is not adequate. | D5 | 2.5 years |
10.4.e. | The route to the toilet room is inaccessible because it lacks adequate turning space. | TR15 | 2.5 years |
10.4.f. | None of the mirrors provided is accessible. | TR5 | 6 months |
10.4.g. | The sanitary napkin dispenser protrudes into the walkway and is not detectable to blind persons using a cane. | AR7 | 6 months |
10.4.h. | The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact. | LS2 | 6 months |
10.4.i. | The lavatory is inaccessible because it has twist-type hardware. | LS4 | 6 months |
10.4.j. | The designated accessible toilet stall is inaccessible because it is 60 1/2 inches long and 33 1/2 inches wide. | TR23 | 2.5 years |
10.4.k. | The designated accessible toilet is inaccessible because the top of the seat is 16 1/2 inches high. | TR9 | 6 months |
10.4.l. | There are no grab bars provided at the designated accessible toilet. | TR18 | 6 months |
11. | Del Hale Community Recreation Bldg (O'Banion Park), located at 931 Center Avenue, Dos Palos | ||
11.1. | Parking: The designated accessible parking is inaccessible because the signs are mounted too low. | P3 | 6 months |
11.2. | Women's Single-User Toilet Room: | ||
11.2.a. | The toilet room sign is not mounted on the latch side of the door and has no raised or Braille characters. | TR11 | 6 months |
11.2.b. | The door is inaccessible because it requires 8 pounds of force to open. | D3 | 6 months |
11.2.c. | None of the mirrors provided is accessible. | TR5 | 6 months |
11.2.d. | The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact. | LS2 | 6 months |
11.2.e. | The toilet is inaccessible because its centerline is 22 inches from the side wall. | TR7 | 2.5 years |
11.2.f. | The toilet is inaccessible because the flush control is on the closed side. | TR4 | 6 months |
11.2.g. | The toilet is inaccessible because the grab bars are mounted 2 inches from the wall. | TR20 | 6 months |
11.3. | Men's Single-User Toilet Room: | ||
11.3.a. | The toilet room sign is not mounted on the latch side of the door and has no raised or Braille characters. | TR11 | 6 months |
11.3.b. | The door is inaccessible because it requires 8 pounds of force to open. | D3 | 6 months |
11.3.c. | None of the mirrors provided is accessible. | TR5 | 6 months |
11.3.d. | The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact. | LS2 | 6 months |
11.3.e. | The toilet is inaccessible because its centerline is 22 inches from the side wall. | TR7 | 2.5 years |
11.4. | Administration Office: The door is inaccessible because knob hardware is used. | D2 | 6 months |
12. | O'Banion Park, located at 931 Center Avenue, Dos Palos | ||
12.1. | Route to Park Amenities: The route is inaccessible because the grass is not firm, stable, and slip resistant. | AR1 | 2.5 years |
12.2. | Route to Toilet Rooms in Park Area: The route is inaccessible because the grass is not firm, stable, and slip resistant. | AR1 | 2.5 years |
12.3. | Women's Toilet Room with Stall (Park Area): | ||
12.3.a. | The toilet room sign is not mounted on the latch side of the door and has no raised or Braille characters. | TR11 | 6 months |
12.3.b. | The paper towel dispenser is inaccessible because it is mounted with the controls 61 inches high. | CT4 | 6 months |
12.3.c. | The lavatory is inaccessible because the bottom of the apron is 25 inches high. | LS3 | 6 months |
12.3.d. | The designated accessible toilet stall is inaccessible because it is 59 inches long and 39 inches wide. | TR23 | 2.5 years |
12.3.e. | The designated accessible toilet is inaccessible because the top of the seat is 15 inches high. | TR9 | 6 months |
12.3.f. | The designated accessible toilet is inaccessible because its centerline is more than 18 inches from the side wall. | TR7 | 6 months |
12.3.g. | The designated accessible toilet is inaccessible because the flush control is mounted behind the toilet. | TR4 | 6 months |
12.3.h. | The toilet paper dispenser in the designated accessible stall is inaccessible because it is mounted opposite the side grab bar. | TR6 | 6 months |
12.3.i. | The designated accessible toilet is inaccessible because the side grab bar is 36 inches long. | TR17 | 6 months |
12.3.j. | There is no rear grab bar provided at the designated accessible toilet. | TR13 | 6 months |
12.4. | Men's Toilet Room with Stall (Park Area): | ||
12.4.a. | The toilet room sign is not mounted on the latch side of the door and has no raised or Braille characters. | TR11 | 6 months |
12.4.b. | The paper towel dispenser is inaccessible because it is mounted with the controls 59 inches high. | CT4 | 6 months |
12.4.c. | The lavatory is inaccessible because the top of the rim or counter is 35 inches high. | LS3 | 6 months |
12.4.d. | The urinal is inaccessible because the rim is 23 inches high and the flush control is 48 inches high. | TR8 | 6 months |
12.4.e. | The designated accessible toilet stall is inaccessible because it is 59 inches long and 38 inches wide. | TR23 | 6 months |
12.4.f. | The designated accessible toilet is inaccessible because the top of the seat is 16 inches high. | TR9 | 6 months |
12.4.g. | The designated accessible toilet is inaccessible because the flush control is mounted behind the toilet. | TR4 | 6 months |
12.4.h. | The designated accessible toilet is inaccessible because the side grab bar is 36 inches long. | TR17 | 6 months |
12.4.i. | There is no rear grab bar provided at the designated accessible toilet. | TR13 | 6 months |
12.5. | Men's Toilet Room with Stall (Baseball Field): | ||
12.5.a. | The toilet room sign is not mounted on the latch side of the door. | TR11 | 6 months |
12.5.b. | None of the mirrors provided is accessible. | TR5 | 6 months |
12.5.c. | The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact. | LS2 | 6 months |
12.5.d. | The urinal is inaccessible because the rim is 23 inches high. | TR8 | 6 months |
12.5.e. | The designated accessible toilet is inaccessible because the side grab bar is mounted 13 inches from the rear wall. | TR16 | 6 months |
12.5.f. | The designated accessible toilet is inaccessible because the side grab bar is obstructed by the toilet paper dispenser. | TR15 | 6 months |
12.6. | Women's Toilet Room with Stall (Baseball Field): | ||
12.6.a. | The toilet room sign is not mounted on the latch side of the door. | TR11 | 6 months |
12.6.b. | None of the mirrors provided is accessible. | TR5 | 6 months |
12.6.c. | The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact. | LS2 | 6 months |
12.6.d. | The designated accessible toilet is inaccessible because its centerline is 19 inches from the side wall. | TR7 | 2.5 years |
12.6.e. | The designated accessible toilet is inaccessible because the side grab bar is mounted 13 inches from the rear wall. | TR17 | 6 months |
12.6.f. | The designated accessible toilet is inaccessible because the side grab bar is obstructed by the toilet paper dispenser. | TR15 | 6 months |
12.7. | Drinking Fountain (Baseball Field): Although a designated accessible drinking fountain is provided, there is no drinking fountain provided for people who have difficulty bending or stooping. | DF3 | 2.5 years |
12.8. | Route to Bleachers and Dugouts: The route is inaccessible because the grass is not firm, stable, and slip resistant. | AR1 | 2.5 years |
12.9. | Parking Lot: The parking lot, with a total of 63 parking spaces, is inaccessible because no van accessible space is provided, it lacks vertical signage, and the parking spaces and access aisles provided are not level. This lot requires one van accessible space and two standard accessible spaces. | P1 | 2.5 years |
13. | Hagaman Park, located at 1991W. River Road, Stevinson | ||
13.1. | Route to Amenities in Park: The route is inaccessible because the grass is not firm, stable, and slip resistant. | AR1 | 2.5 years |
13.2. | Picnic Tables: The picnic tables are inaccessible because none provide the required knee space. | DW1 | 6 months |
13.3. | Route to Drinking Fountain: The route is inaccessible because the grass is not firm, stable, and slip resistant. | AR1 | 2.5 years |
13.4. | Drinking Fountain: The drinking fountain contains a number of inaccessible elements and is not accessible to people with disabilities. | DF1 | 2.5 years |
13.5. | Route to Toilet Rooms: The route is inaccessible because the grass is not firm, stable, and slip resistant. | AR1 | 2.5 years |
13.6. | Women's Toilet Room with Stall Near Play Area: The toilet room contains a number of inaccessible elements and is not accessible to people with disabilities. | TR1 | 2.5 years |
13.7. | Men's Toilet Room with Stall Near Play Area: The toilet room contains a number of inaccessible elements and is not accessible to people with disabilities. | TR1 | 2.5 years |
13.8. | Route to Play Area: The route is inaccessible because the grass is not firm, stable, and slip resistant. | AR1 | 2.5 years |
13.9. | Route to J. H. Mahoney Picnic Shelter: The route is inaccessible because the grass is not firm, stable, and slip resistant. | AR1 | 2.5 years |
13.10. | J. H. Mahoney Picnic Shelter: The picnic tables are inaccessible because none provide the required knee space. | DW1 | 2.5 years |
13.11. | Women's Toilet Room with Stall Near J. H. Mahoney Picnic Shelter: The toilet room contains a number of inaccessible elements and is not accessible to people with disabilities. | TR1 | 2.5 years |
13.12. | Men's Toilet Room with Stall Near J. H. Mahoney Picnic Shelter: The toilet room contains a number of inaccessible elements and is not accessible to people with disabilities. | TR1 | 2.5 years |
13.13. | Route to Toilet Rooms Near Caretaker's House: The route is inaccessible because the grass is not firm, stable, and slip resistant. | AR1 | 2.5 years |
13.14. | Men's Toilet Room with Stall Near Caretaker's House: The toilet room contains a number of inaccessible elements and is not accessible to people with disabilities. | TR1 | 2.5 years |
13.15. | Women's Toilet Room with Stall Near Caretaker's House: The toilet room contains a number of inaccessible elements and is not accessible to people with disabilities. | TR1 | 2.5 years |
14. | Cherish Senior Center, located at 851 W. 23rd Street | ||
14.1. | Lobby Area: The drinking fountain protrudes into the walkway and is not detectable to blind persons using a cane. | AR7 | 6 months |
14.2. | Drinking Fountain: Although a designated accessible drinking fountain is provided, there is no drinking fountain provided for people who have difficulty bending or stooping. | DF3 | 2.5 years |
14.3. | Multi-Purpose Room: | ||
14.3.a. | The door is inaccessible because it has an opening width of 30 inches. | D14 | 2.5 years |
14.3.b. | The door is inaccessible because knob hardware is used. | D2 | 6 months |
14.4. | Unisex Toilet Room with stall: | ||
14.4.a. | The toilet room sign is not mounted on the latch side of the door. | TR11 | 6 months |
14.4.b. | The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact. | LS2 | 6 months |
14.4.c. | The urinal is inaccessible because the rim is 23 1/2 inches high and the height of the flush control is more than 44 inches. | TR8 | 6 months |
14.4.d. | The designated accessible stall is incorrectly configured as an ambulatory stall, and there is no standard accessible stall provided. | TR23 | 2.5 years |
14.4.e. | The designated accessible toilet is inaccessible because the top of the seat is 16 inches high. | TR9 | 6 months |
14.4.f. | No accessible coat hook has been provided. | TR3 | 6 months |
15. | Le Grand Branch Library, located at 12949 Le Grand Road, Le Grand | ||
15.1. | Women's Toilet Room with Stall (By Entrance): The door is inaccessible because it requires 10 pounds of force to open. | D3 | 6 months |
15.2. | Men's Single-User Toilet Room: The door is inaccessible because it requires 10 pounds of force to open. | D3 | 6 months |
16. | Merced County Main Library, located at 2100 O Street | ||
16.1. | Parking: | ||
16.2. | Ramp (On Route to Main Entrance): | ||
16.2.a. | The ramp is inaccessible because both handrails are mounted 43 inches above the ramp surface. | R2 | 2.5 years |
16.3. | Second Floor Drinking Fountain (By Main Entrance): The drinking fountain is inaccessible because the knee space between the bottom of the apron and the finished floor is less than 27 inches. | DF4 | 2.5 years |
16.4. | Second Floor Unisex Single-User Toilet Room: The toilet room contains a number of inaccessible elements and is not accessible to people with disabilities. | TR1 | 2.5 years |
16.5. | First Floor Unisex Single-User Toilet Room: | ||
16.5.a. | The toilet room sign is not mounted on the latch side of the door and has no raised or Braille characters. | TR11 | 6 months |
16.5.b. | The door is inaccessible because it requires 15 pounds of force to open. | D3 | 6 months |
16.5.c. | No accessible coat hook has been provided. | TR3 | 6 months |
16.5.d. | The urinal is inaccessible because the rim is 19 inches high and the flush control is 50 inches high. | TR8 | 6 months |
16.6. | First Floor Women's Toilet Room with Stall (By Gracey Room): | ||
16.6.a. | The toilet room sign is not mounted on the latch side of the door and has no raised or Braille characters. | TR11 | 6 months |
16.6.b. | The door is inaccessible because it requires 14 pounds of force to open. | D3 | 6 months |
16.6.c. | The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact. | LS2 | 6 months |
16.6.d. | The designated accessible toilet stall is inaccessible because it is 59 inches long and 42 inches wide. | TR23 | 2.5 years |
16.6.e. | The designated accessible toilet is inaccessible because its centerline is 20 inches from the side wall. | TR7 | 2.5 years |
16.6.f. | No accessible coat hook has been provided. | TR3 | 6 months |
16.7. | First Floor Men's Toilet Room with Stall (By Gracey Room): | ||
16.7.a. | The toilet room sign is not mounted on the latch side of the door and has no raised or Braille characters. | TR11 | 6 months |
16.7.b. | The door is inaccessible because it requires 10 pounds of force to open. | D3 | 6 months |
16.7.c. | The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact. | LS2 | 6 months |
16.7.d. | The urinal is inaccessible because the rim is 20 inches high and the flush control is 48 inches high. | TR8 | 6 months |
16.7.e. | No accessible coat hook has been provided. | TR3 | 6 months |
16.8. | Third Floor Women's Single-User Toilet Room: The toilet room contains a number of inaccessible elements and is not accessible to people with disabilities. | TR1 | 2.5 years |
16.9. | Third Floor Men's Single-User Toilet Room: The toilet room contains a number of inaccessible elements and is not accessible to people with disabilities. | TR1 | 2.5 years |
17. | Administrative Services, located at 2222 M Street | ||
17.1. | First Floor Treasurer Office: The door is inaccessible because it requires 8 pounds of force to open. | D3 | 6 months |
17.2. | First Floor Men's Toilet Room with Stalls, Room No. 101, Staff: | ||
17.2.a. | The doors are inaccessible because they require 10 pounds of force to open. | D3 | 6 months |
17.2.b. | Although an audible alarm is provided in this facility, there is no visual alarm appliance in the toilet room. | AL1 | 6 months |
17.2.c. | The paper seat cover dispenser is inaccessible because it is mounted with the controls 61 inches high. | CT4 | 6 months |
17.2.d. | The paper towel dispenser is inaccessible because the controls are mounted 57 inches high and require twisting of the wrist to operate. | CT1 | 6 months |
17.2.e. | The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact. | LS2 | 6 months |
17.2.f. | The lavatory is inaccessible because it has twist-type hardware. | LS4 | 6 months |
17.2.g. | The urinal is inaccessible because the rim is 24 inches high, the flush control is over 44 inches high, and the clear floor space is 29 1/2 inches wide. | TR8 | 6 months |
17.2.h. | The designated accessible stall is incorrectly configured as an ambulatory stall, and there is no standard accessible stall provided. | TR23 | 2.5 years |
17.2.i. | No accessible coat hook has been provided. | TR3 | 6 months |
17.2.j. | The designated accessible toilet is inaccessible because the side grab bar is obstructed by the toilet paper dispenser. | TR15 | 6 months |
17.3. | First Floor Women's Toilet Room with Stalls, Room No. 104, Staff: | ||
17.3.a. | The toilet room sign is not mounted on the latch side of the door and has no raised or Braille characters. | TR11 | 6 months |
17.3.b. | The doors are inaccessible because they require 10 pounds of force to open. | D3 | 6 months |
17.3.c. | Although an audible alarm is provided in this facility, there is no visual alarm appliance in the toilet room. | AL1 | 6 months |
17.3.d. | The paper seat cover dispenser is inaccessible because it is mounted with the controls 62 inches high. | CT4 | 6 months |
17.3.e. | The paper towel dispenser is inaccessible because the controls are mounted 56 inches high and require twisting of the wrist to operate. | CT1 | 6 months |
17.3.f. | The sanitary napkin dispenser is inaccessible because the controls require twisting of the wrist to operate. | CT2 | 6 months |
17.3.g. | The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact. | LS2 | 6 months |
17.3.h. | The lavatory is inaccessible because it has twist-type hardware. | LS4 | 6 months |
17.3.i. | The designated accessible stall is incorrectly configured as an ambulatory stall, and there is no standard accessible stall provided. | TR23 | 2.5 years |
17.3.j. | No accessible coat hook has been provided. | TR3 | 6 months |
17.3.k. | The designated accessible toilet is inaccessible because the side grab bar is obstructed by the toilet paper dispenser. | TR15 | 6 months |
17.4. | First Floor Men's Toilet Room with Stalls, Public: | ||
17.4.a. | The toilet room sign is not mounted on the latch side of the door and has no raised or Braille characters. | TR11 | 6 months |
17.4.b. | The doors are inaccessible because they require more than 7 pounds of force to open. | D3 | 6 months |
17.4.c. | The door is inaccessible because knob hardware is used. | D2 | 6 months |
17.4.d. | Although an audible alarm is provided in this facility, there is no visual alarm appliance in the toilet room. | AL1 | 6 months |
17.4.e. | The paper seat cover dispenser is inaccessible because it is mounted with the controls 60 inches high. | CT4 | 6 months |
17.4.f. | The paper towel dispenser is inaccessible because the controls require twisting of the wrist to operate. | CT2 | 6 months |
17.4.g. | The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact. | LS2 | 6 months |
17.4.h. | The lavatory is inaccessible because it has twist-type hardware. | LS4 | 6 months |
17.4.i. | The urinal is inaccessible because the rim is 24 inches high, the flush control is over 44 inches high, and the clear floor space is 29 inches wide. | TR8 | 6 months |
17.4.j. | The designated accessible stall is incorrectly configured as an ambulatory stall, and there is no standard accessible stall provided. | TR23 | 2.5 years |
17.4.k. | No accessible coat hook has been provided. | TR3 | 6 months |
17.4.l. | The designated accessible toilet is inaccessible because the side grab bar is obstructed by the toilet paper dispenser. | TR15 | 6 months |
17.5. | First Floor Women's Toilet Room with Stalls, Public: | ||
17.5.a. | The toilet room sign is not mounted on the latch side of the door and has no raised or Braille characters. | TR11 | 6 months |
17.5.b. | The doors are inaccessible because they require more than 7 pounds of force to open. | D3 | 6 months |
17.5.c. | The door is inaccessible because knob hardware is used. | D2 | 6 months |
17.5.d. | Although an audible alarm is provided in this facility, there is no visual alarm appliance in the toilet room. | AL1 | 6 months |
17.5.e. | None of the mirrors provided is accessible. | TR5 | 6 months |
17.5.f. | The paper seat cover dispenser is inaccessible because it is mounted with the controls 61 inches high. | CT4 | 6 months |
17.5.g. | The paper towel dispenser is inaccessible because the controls are mounted 58 inches high and require twisting of the wrist to operate. | CT1 | 6 months |
17.5.h. | The sanitary napkin dispenser is inaccessible because the controls require twisting of the wrist to operate. | CT2 | 6 months |
17.5.i. | The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact. | LS2 | 6 months |
17.5.j. | The lavatory is inaccessible because it has twist-type hardware. | LS4 | 6 months |
17.5.k. | The designated accessible stall is incorrectly configured as an ambulatory stall, and there is no standard accessible stall provided. | TR23 | 2.5 years |
17.5.l. | No accessible coat hook has been provided. | TR3 | 6 months |
17.5.m. | The designated accessible toilet is inaccessible because the side grab bar is obstructed by the toilet paper dispenser. | TR15 | 6 months |
17.6. | First Floor Recorder Office: The door is inaccessible because it requires 12 pounds of force to open. | D3 | 6 months |
17.7. | First Floor Revenue and Reimbursement Office: The door is inaccessible because it requires 12 pounds of force to open. | D3 | 6 months |
17.8. | First Floor Drinking Fountains: The drinking fountains are inaccessible because the controls requires more than 5 pounds of force to operate, the knee space height is less than 27 inches high, and there are no drinking fountains provided for people who have difficulty bending or stooping. | DF1 | 6 months |
17.9. | Third Floor County Counsel Office Room 309: | ||
17.9.a. | The door is inaccessible because it requires 10 pounds of force to open. | D3 | 6 months |
17.9.b. | The door is inaccessible because knob hardware is used. | D2 | 6 months |
17.9.c. | The route to the library is inaccessible because path of travel by the library door is 31 inches wide. | AR3 | 6 months |
17.10. | Third Floor Human Resources Office: | ||
17.10.a. | The door is inaccessible because knob hardware is used. | D2 | 6 months |
17.11. | Third Floor Women's Toilet Room with Stalls, Public: | ||
17.11.a. | The toilet room sign is not mounted on the latch side of the door and has no raised or Braille characters. | TR11 | 6 months |
17.11.b. | The doors are inaccessible because they require more than 10 pounds of force to open. | D3 | 6 months |
17.11.c. | Although an audible alarm is provided in this facility, there is no visual alarm appliance in the toilet room. | AL1 | 6 months |
17.11.d. | The paper seat cover dispenser is inaccessible because it is mounted with the controls 60 inches high. | CT4 | 6 months |
17.11.e. | The paper towel dispenser is inaccessible because the controls are mounted 58 inches high and require twisting of the wrist to operate. | CT1 | 6 months |
17.11.f. | The sanitary napkin dispenser is inaccessible because the controls require twisting of the wrist to operate. | CT2 | 6 months |
17.11.g. | The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact. | LS2 | 6 months |
17.11.h. | The designated accessible stall is incorrectly configured as an ambulatory stall, and there is no standard accessible stall provided. | TR23 | 2.5 years |
17.11.i. | No accessible coat hook has been provided. | TR3 | 6 months |
17.11.j. | The designated accessible toilet is inaccessible because the side grab bar is obstructed by the toilet paper dispenser. | TR15 | 6 months |
17.12. | Third Floor Men's Toilet Room with Stalls, Public: | ||
17.12.a. | The toilet room sign is not mounted on the latch side of the door and has no raised or Braille characters. | TR11 | 6 months |
17.12.b. | The doors are inaccessible because they require 10 pounds of force to open. | D3 | 6 months |
17.12.c. | Although an audible alarm is provided in this facility, there is no visual alarm appliance in the toilet room. | AL1 | 6 months |
17.12.d. | The paper seat cover dispenser is inaccessible because it is mounted with the controls 56 inches high. | CT4 | 6 months |
17.12.e. | The paper towel dispenser is inaccessible because the controls are mounted 58 inches high and require twisting of the wrist to operate. | CT2 | 6 months |
17.12.f. | The urinal is inaccessible because the rim is 23 inches high, the flush control is over 44 inches high, and the clear floor space is 29 inches wide. | TR8 | 6 months |
17.12.g. | The designated accessible stall is incorrectly configured as an ambulatory stall, and there is no standard accessible stall provided. | TR23 | 2.5 years |
17.12.h. | No accessible coat hook has been provided. | TR3 | 6 months |
17.12.i. | The designated accessible toilet is inaccessible because the side grab bar is obstructed by the toilet paper dispenser. | TR15 | 6 months |
17.13. | Third Floor Board of Supervisors Office: | ||
17.13.a. | The door is inaccessible because it requires 10 pounds of force to open. | D3 | 6 months |
17.13.b. | The door is inaccessible because knob hardware is used. | D2 | 6 months |
17.14. | Third Floor Board of Supervisors Board Room: | ||
17.14.a. | The door is inaccessible because it requires 11 pounds of force to open. | D3 | 6 months |
17.14.b. | The door is inaccessible because thumb latch hardware is used. | D2 | 6 months |
17.14.c. | The signage provided is inaccessible because it does not have raised and Braille characters. | D15 | 6 months |
17.15. | Third Floor Meeting Room 301: | ||
17.15.a. | The signage provided is inaccessible because it does not have raised and Braille characters. | D15 | 6 months |
17.15.b. | The door is inaccessible because knob hardware is used. | D2 | 6 months |
17.16. | Third Floor CEO Budget Room 301A: | ||
17.16.a. | The door is inaccessible because it requires 11 pounds of force to open. | D3 | 6 months |
17.16.b. | The door is inaccessible because knob hardware is used. | D2 | 6 months |
17.16.c. | The signage provided is inaccessible because it does not have raised and Braille characters. | D15 | 6 months |
17.17. | Third Floor Director of Governmental Affairs, Room 304: | ||
17.17.a. | The door is inaccessible because it requires 10 pounds of force to open. | D3 | 6 months |
17.17.b. | The door is inaccessible because knob hardware is used. | D2 | 6 months |
17.17.c. | The signage provided is inaccessible because it does not have raised and Braille characters. | D15 | 6 months |
17.18. | Third Floor Congressman Office Room 305: | ||
17.18.a. | The door is inaccessible because it requires 10 pounds of force to open. | D3 | 6 months |
17.18.b. | The door is inaccessible because knob hardware is used. | D2 | 6 months |
17.18.c. | The signage provided is inaccessible because it does not have raised and Braille characters. | D15 | 6 months |
17.19. | Third Floor Meeting Room 310: | ||
17.19.a. | The door is inaccessible because it requires 11 pounds of force to open. | D3 | 6 months |
17.19.b. | The door is inaccessible because knob hardware is used. | D2 | 6 months |
17.19.c. | The signage provided is inaccessible because it does not have raised and Braille characters. | D15 | 6 months |
17.20. | Third Floor Board of Supervisors District Five: | ||
17.20.a. | The door is inaccessible because it requires 11 pounds of force to open. | D3 | 6 months |
17.20.b. | The door is inaccessible because knob hardware is used. | D2 | 6 months |
17.20.c. | The signage provided is inaccessible because it does not have raised and Braille characters. | D15 | 6 months |
17.21. | Third Floor Building and Safety Division: | ||
17.21.a. | The door is inaccessible because it requires 11 pounds of force to open. | D3 | 6 months |
17.21.b. | The signage provided is inaccessible because it does not have raised and Braille characters. | D15 | 6 months |
17.22. | Third Floor Planning Office: | ||
17.22.a. | The door is inaccessible because it requires 10 pounds of force to open. | D3 | 6 months |
17.22.b. | The office is inaccessible because permanent room signage is not provided. | D15 | 6 months |
17.23. | Third Floor Assessor Office: | ||
17.23.a. | The door is inaccessible because it requires 10 pounds of force to open. | D3 | 6 months |
17.23.b. | The office is inaccessible because permanent room signage is not provided. | D15 | 6 months |
17.24. | Administrative Services (Purchasing/Information Systems) Room 1-2, Basement: | ||
17.24.a. | The door is inaccessible because knob hardware is used. | D2 | 6 months |
17.24.b. | The signage provided is inaccessible because it does not have raised and Braille characters. | D15 | 6 months |
17.25. | Information Systems (Data, Pickup, Mailroom) Room 6, Basement: | ||
17.25.a. | The door is inaccessible because it requires 10 pounds of force to open. | D3 | 6 months |
17.25.b. | The door is inaccessible because knob hardware is used. | D2 | 6 months |
17.25.c. | The signage provided is inaccessible because it does not have raised and Braille characters. | D15 | 6 months |
17.26. | Elections Room 14, Basement: | ||
17.26.a. | The door is inaccessible because it requires 9 pounds of force to open. | D3 | 6 months |
17.26.b. | The door is inaccessible because knob hardware is used. | D2 | 6 months |
17.26.c. | The office is inaccessible because permanent room signage is not provided. | D15 | 6 months |
17.27. | Parking, North and South Lots: The parking lots, with a total of 244 parking spaces, are inaccessible because it has a total of 4 spaces designated as accessible. This lot requires one van accessible space and six standard accessible spaces. | P1 | 6 months |
17.28. | Elevator: The elevator is inaccessible because the emergency system requires voice communication to operate, and it requires tight grasping or pinching to access. | E7 | 6 months |
18. | Lake Yosemite County Park, located at 5620 N. Lake Road | ||
18.1. | Merced Rotary Club (Near Lake) Parking Lot: The parking lot, with a total of 34 parking spaces, is inaccessible because the access aisle adjacent to the designated van accessible space is 61 inches wide, and the van accessible space lacks signage. | P5 | 2.5 years |
18.2. | Merced Rotary Club (Near Lake) Route to Picnic Tables: The route is inaccessible because the grass is not firm, stable, and slip resistant. | AR1 | 2.5 years |
18.3. | Merced Rotary Club (Near Lake) Women's Toilet Room with Stalls Near: | ||
18.3.a. | The toilet room sign is not mounted on the latch side of the door and has no raised or Braille characters. | TR11 | 6 months |
18.3.b. | The designated accessible toilet is inaccessible because its centerline is 20 inches from the side wall. | TR7 | 2.5 years |
18.3.c. | The designated accessible toilet is inaccessible because the rear grab bar is 30 inches long. | TR14 | 6 months |
18.4. | Merced Rotary Club (Near Lake) Men's Toilet Room with Stalls: | ||
18.4.a. | The toilet room sign is not mounted on the latch side of the door and has no raised or Braille characters. | TR11 | 6 months |
18.4.b. | The door is inaccessible because knob hardware is used. | D2 | 6 months |
18.4.c. | The designated accessible toilet is inaccessible because its centerline is 20 inches from the side wall. | TR7 | 2.5 years |
18.4.d. | The designated accessible toilet is inaccessible because the side grab bar is obstructed by the toilet paper dispenser. | TR15 | 6 months |
18.4.e. | The designated accessible toilet is inaccessible because the rear grab bar is 30 inches long. | TR14 | 6 months |
18.5. | Merced Rotary Club Parking Lot (Near Veterans Cove): | ||
18.5.a. | The parking lot, with a total of 39 parking spaces, is inaccessible because there is only one access aisle provided for three designated accessible spaces, the access aisle provided is 56 inches wide, and the designated van accessible space lacks signage. | P1 | 2.5 years |
18.5.b. | The designated accessible parking is inaccessible because it slopes 6.6% and has a cross slope of 7.2%. | P4 | 2.5 years |
18.6. | Merced Rotary Club Kitchen Area: The paper towel dispensers are inaccessible because they are mounted with the controls 57 inches and 64 inches high. | CT4 | 6 months |
18.7. | Merced Rotary Club Route to Picnic Tables and Benches Near Lake: The route is inaccessible because the grass is not firm, stable, and slip resistant. | AR1 | 2.5 years |
18.8. | Merced Rotary Club Men's Toilet Room with Stalls: | ||
18.8.a. | The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact. | LS2 | 6 months |
18.8.b. | The designated accessible toilet is inaccessible because its centerline is 20 inches from the side wall. | TR7 | 2.5 years |
18.9. | Merced Rotary Club Women's Toilet Room with Stalls: | ||
18.9.a. | The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact. | LS2 | 6 months |
18.9.b. | The designated accessible toilet is inaccessible because its centerline is 20 inches from the side wall. | TR7 | 2.5 years |
18.9.c. | Although there are 8 toilet stalls, there is no ambulatory stall provided. | TR22 | 2.5 years |
18.10. | Merced Rotary Club Parking Lot (Near Veterans Cove): | ||
18.10.a. | The parking lot, with a total of 80 parking spaces, is inaccessible because there are no access aisles provided, and the van accessible space lacks signage. | P1 | 2.5 years |
18.10.b. | The designated accessible parking is inaccessible because it slopes 4.7% and has a cross slope of 8.4%. | P4 | 6 months |
18.11. | Veterans Cove Pavilion: | ||
18.11.a. | The picnic tables are inaccessible because none provide the required knee space. | DW1 | 6 months |
18.11.b. | The kitchen door is inaccessible because knob hardware is used. | D2 | 6 months |
18.12. | Route from Parking Lot to Pavilion: The route is inaccessible because it has a slope of 17.8% and a cross-slope of 5.2%. | AR1 | 2.5 years |
18.13. | Route from Parking Lot to Kitchen: The route is inaccessible because it has a slope of 17% and a cross-slope of 4.4%. | AR1 | 2.5 years |
18.14. | Drinking Fountain: | ||
18.14.a. | The drinking fountain is inaccessible because the controls require tight grasping, pinching, or twisting of the wrist to operate. | DF2 | 2.5 years |
18.14.b. | The wall-mounted drinking fountain is inaccessible because it provides only 23 inches of clear knee height. | DF4 | 2.5 years |
18.14.c. | Although a designated accessible drinking fountain is provided, there is no drinking fountain provided for people who have difficulty bending or stooping. | DF3 | 2.5 years |
18.15. | Veterans Cove Men's Toilet Room with Stalls: | ||
18.15.a. | The toilet room sign is not mounted on the latch side of the door and has no raised or Braille characters. | TR11 | 6 months |
18.15.b. | The door is inaccessible because knob hardware is used. | D2 | 6 months |
18.15.c. | The paper towel dispenser is inaccessible because it is mounted with the controls 69 inches high. | CT4 | 6 months |
18.15.d. | The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact. | LS2 | 6 months |
18.15.e. | The lavatory is inaccessible because it has clear floor space less than 30 inches wide. | LS5 | 6 months |
18.15.f. | The lavatory is inaccessible because it has twist-type hardware. | LS4 | 6 months |
18.15.g. | The urinal is inaccessible because the rim is 22 inches high and the width of the clear floor space is less than 30 inches. | TR8 | 6 months |
18.15.h. | There is no accessible toilet stall provided. | TR2 | 6 months |
18.16. | Veterans Cove Men's Toilet Room with Stalls: | ||
18.16.a. | The toilet room sign is not mounted on the latch side of the door and has no raised or Braille characters. | TR11 | 6 months |
18.16.b. | The door is inaccessible because knob hardware is used. | D2 | 6 months |
18.16.c. | The paper towel dispenser is inaccessible because it is mounted with the controls 68 inches high. | CT4 | 6 months |
18.16.d. | The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact. | LS2 | 6 months |
18.16.e. | The lavatory is inaccessible because it has clear floor space less than 30 inches wide. | LS5 | 2.5 years |
18.16.f. | The lavatory is inaccessible because it has twist-type hardware. | LS4 | 6 months |
18.16.g. | There is no accessible toilet stall provided. | TR2 | 2.5 years |
18.17. | Route to Scott Island: The route is inaccessible because the grass is not firm, stable, and slip resistant. | AR1 | 2.5 years |
18.18. | Route to Amenities (Picnic Tables, Grills, Drinking Fountain, and Toilet Rooms): The route is inaccessible because the grass is not firm, stable, and slip resistant. | AR1 | 2.5 years |
18.19. | Scott Island Men's Toilet Room with Stalls: | ||
18.19.a. | The toilet room sign is not mounted on the latch side of the door and has no raised or Braille characters. | TR11 | 6 months |
18.19.b. | The door is inaccessible because it has an opening width of 31 inches. | D14 | 2.5 years |
18.19.c. | There is no accessible toilet stall provided. | TR2 | 2.5 years |
18.19.d. | The toilet room contains a number of inaccessible elements and is not accessible to people with disabilities. | TR1 | 2.5 years |
18.20. | Scott Island Women's Toilet Room with Stalls: | ||
18.20.a. | The toilet room sign is not mounted on the latch side of the door and has no raised or Braille characters. | TR11 | 6 months |
18.20.b. | The door is inaccessible because it has an opening width of 31 inches. | D14 | 2.5 years |
18.20.c. | There is no accessible toilet stall provided. | TR2 | 2.5 years |
18.20.d. | The toilet room contains a number of inaccessible elements and is not accessible to people with disabilities. | TR1 | 2.5 years |
18.21. | Bedesen Beach Parking Lot (Near Toilet Rooms): The designated accessible parking is inaccessible because it slopes greater than 8.2% and has a cross slope greater than 3.7%. | P4 | 2.5 years |
18.22. | Drinking Fountain (Near Toilet Rooms): Although a designated accessible drinking fountain is provided, there is no drinking fountain provided for people who have difficulty bending or stooping. | DF3 | 2.5 years |
18.23. | Bedesen Beach Women's Toilet Room with Stalls: | ||
18.23.a. | The toilet room sign is not mounted on the latch side of the door and has no raised or Braille characters. | TR11 | 6 months |
18.23.b. | The designated accessible toilet is inaccessible because its centerline is 22 inches from the side wall. | TR7 | 2.5 years |
18.23.c. | The designated accessible toilet is inaccessible because the flush control is on the closed side. | TR4 | 6 months |
18.24. | Bedesen Beach Men's Toilet Room with Stalls: | ||
18.24.a. | The toilet room sign is not mounted on the latch side of the door and has no raised or Braille characters. | TR11 | 6 months |
18.24.b. | The designated accessible toilet is inaccessible because its centerline is 19 1/2 inches from the side wall. | TR7 | 2.5 years |
18.25. | Route to Picnic Tables: The route is inaccessible because the grass is not firm, stable, and slip resistant. | AR1 | 2.5 years |
18.26. | Bedesen Beach Parking Lot (Near Play Area): The parking lot, with a total of 17 parking spaces, is inaccessible because it lacks van accessible signage and the width of the access aisle adjacent to the van accessible space is less than 96 inches wide. This lot requires van accessible space. | P5 | 2.5 years |
18.27. | Route to Play Area: The route is inaccessible because the grass is not firm, stable, and slip resistant. | AR1 | 2.5 years |
18.28. | Route to Picnic Tables: The route is inaccessible because the grass is not firm, stable, and slip resistant. | AR1 | 2.5 years |
18.29. | Merced Fish and Game Clubhouse Parking Lot: The parking lot, with a total of 48 parking spaces, is inaccessible because there are no access aisles provided, and the van accessible space lacks signage. This lot requires one van accessible space and two standard accessible spaces. | P1 | 2.5 years |
18.30. | Merced Fish and Game Clubhouse: | ||
18.30.a. | The exterior entrance door is inaccessible because it requires tight grasping, pinching, or twisting of the wrist to operate. | D2 | 6 months |
18.30.b. | Many of the interior doors are inaccessible because knob hardware is used. | D2 | 6 months |
18.30.c. | The paper towel dispenser in the kitchen area is inaccessible because it is mounted with the controls 67 inches high. | CT4 | 6 months |
18.31. | Men's Toilet Room with Stalls: | ||
18.31.a. | The toilet room sign is not mounted on the latch side of the door and has no raised or Braille characters. | TR11 | 6 months |
18.31.b. | The door is inaccessible because it has an opening width of 29 inches. | D14 | 2.5 years |
18.31.c. | None of the mirrors provided is accessible. | TR5 | 6 months |
18.31.d. | The paper towel dispenser is inaccessible because it is mounted with the controls 61 inches high. | CT4 | 6 months |
18.31.e. | The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact. | LS2 | 6 months |
18.31.f. | The lavatory is inaccessible because it has twist-type hardware. | LS4 | 6 months |
18.31.g. | The urinal is inaccessible because the rim is 24 inches high. | TR8 | 6 months |
18.31.h. | The designated accessible toilet stall is inaccessible because it is 49 inches long and 37 inches wide. | TR23 | 2.5 years |
18.31.i. | The designated accessible toilet is inaccessible because no side grab bar is provided. | TR16 | 6 months |
18.31.j. | The designated accessible toilet is inaccessible because the rear grab bar is 24 inches long. | TR14 | 6 months |
18.32. | Women's Toilet Room with Stalls: | ||
18.32.a. | The toilet room sign is not mounted on the latch side of the door and has no raised or Braille characters. | TR11 | 6 months |
18.32.b. | The door is inaccessible because it has an opening width of 29 inches. | D14 | 2.5 years |
18.32.c. | The paper towel dispenser is inaccessible because it is mounted with the controls 66 inches high. | CT4 | 6 months |
18.32.d. | The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact. | LS2 | 6 months |
18.32.e. | The lavatory is inaccessible because it has twist-type hardware. | LS4 | 6 months |
18.32.f. | The designated accessible toilet stall is inaccessible because it is 48 inches long and 34 inches wide. | TR23 | 2.5 years |
18.32.g. | The designated accessible toilet is inaccessible because the rear grab bar is 24 inches long. | TR14 | 6 months |
18.33. | Route to Toilet Rooms with Stalls Near Bridge: The route is inaccessible because the grass is not firm, stable, and slip resistant. | AR1 | 2.5 years |
18.34. | Men's & Women's Toilet Room with Stalls By Bridge: The toilet room contains a number of inaccessible elements and is not accessible to people with disabilities. | TR1 | 2.5 years |
18.35. | Route to Amenities Near Bridge (Picnic Tables, Benches and Grills): The route is inaccessible because the grass is not firm, stable, and slip resistant. | AR1 | 2.5 years |
18.36. | Route to Drinking Fountain Near Bridge: The route is inaccessible because the grass is not firm, stable, and slip resistant. | AR1 | 2.5 years |
18.37. | Route to Bridge: The route is inaccessible because the grass is not firm, stable, and slip resistant. | AR1 | 2.5 years |
18.38. | Route to Amenities Near Employee Area (Picnic Tables and Grills): The route is inaccessible because the grass is not firm, stable, and slip resistant. | AR1 | 2.5 years |
18.39. | Parking Lot Near Employee Area & Pier: The parking lot, with a total of 20 parking spaces, is inaccessible because there are no access aisles provided, and the van accessible space lacks signage. This lot requires one van accessible space. | P1 | 2.5 years |
18.40. | Route to Toilet Rooms Near Pier: The route is inaccessible because the grass is not firm, stable, and slip resistant. | AR1 | 2.5 years |
18.41. | Men's and Women's Toilet Room with Stalls Near Pier: The toilet room contains a number of inaccessible elements and is not accessible to people with disabilities. | TR1 | 2.5 years |
18.42. | Route to Play Area: The route is inaccessible because the grass is not firm, stable, and slip resistant. | AR1 | 2.5 years |
18.43. | Route to Play Equipment: The route is inaccessible because there is a three inch change in level at the curb ramp. | AR1 | 2.5 years |
18.44. | Route to Pier: The route is inaccessible because the grass is not firm, stable, and slip resistant and there is a 2 1/2 change in level at beginning of pier. | AR1 | 2.5 years |
18.45. | Route to Amenities Near Pier (Picnic Tables, Grills, and Basketball Court): The route is inaccessible because the grass is not firm, stable, and slip resistant. | AR1 | 2.5 years |
18.46. | Route to Drinking Fountain: The route is inaccessible because the grass is not firm, stable, and slip resistant. | AR1 | 2.5 years |
18.47. | Men's and Women's Toilet Room with Stalls Near Boat Launch: The toilet rooms contain a number of inaccessible elements and are not accessible to people with disabilities. | TR1 | 2.5 years |
18.48. | Men's Toilet Room with Stalls Near Sailing Association: | ||
18.48.a. | The toilet room sign is not mounted on the latch side of the door and has no raised or Braille characters. | TR11 | 6 months |
18.48.b. | None of the mirrors provided is accessible. | TR5 | 6 months |
18.48.c. | The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact. | LS2 | 6 months |
18.49. | Women's Toilet Room with Stalls Near Sailing Association: | ||
18.49.a. | The toilet room sign is not mounted on the latch side of the door and has no raised or Braille characters. | TR11 | 6 months |
18.49.b. | None of the mirrors provided is accessible. | TR5 | 6 months |
18.49.c. | The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact. | LS2 | 6 months |
18.49.d. | The designated accessible toilet is inaccessible because its centerline is 19 inches from the side wall. | TR7 | 6 months |
18.50. | Parking Lot Near Employee Area and Sailing Association: The parking lot, with a total of 103 parking spaces, is inaccessible because the van accessible space is 62 inches wide and lacks signage, and two of the access aisles are 58 inches wide. This lot requires one van accessible space and four standard accessible spaces. | P1 | 2.5 years |
18.51. | Parking Lot Near Sailing Association: The parking lot, with a total of 50 parking spaces, is inaccessible because it lacks signage for the designated accessible spaces, and no access aisles are provided. This lot requires one van accessible space and one standard accessible space. | P1 | 2.5 years |
18.52. | Bicentennial Grove Parking Lot Near Bike Path: The parking lot, with a total of 20 parking spaces, is inaccessible because it lacks van accessible signage, and the access aisle is too narrow. This lot requires one van accessible space. | P5 | 2.5 years |
18.53. | Bicentennial Grove Parking Lot Near Softball Field: The parking lot, with a total of 94 parking spaces, is inaccessible because it lacks signage for a van accessible space and two standard accessible spaces, three of the access aisles are too narrow, and two of the access aisles are not level. This lot requires one van accessible space and three standard accessible spaces. | P1 | 2.5 years |
18.54. | Bicentennial Grove Parking Lot: The parking lot, with a total of 71 parking spaces, is inaccessible because it lacks signage for the accessible spaces, and no access aisles are provided. This lot requires one van accessible space and two standard accessible spaces. | P1 | 2.5 years |
18.55. | Bicentennial Grove Route to Amenities (Picnic Tables, Grills, Benches, and Softball Field): The route is inaccessible because the grass is not firm, stable, and slip resistant. | AR1 | 2.5 years |
18.56. | Route to Drinking Fountain: The route is inaccessible because the grass is not firm, stable, and slip resistant. | AR1 | 2.5 years |
18.57. | Route from Parking Lot to Toilet Rooms: The route is inaccessible because there is a 1 in change in level at the curb ramp. | AR1 | 2.5 years |
18.58. | Bicentennial Grove Men's and Women's Toilet Room: The toilet room contains a number of inaccessible elements and is not accessible to people with disabilities. | TR1 | 2.5 years |