Barrier Number Floor Location Number Description Condition Barrier notes Standards
177 01 C-108 Time Clock in Elevator Lobby 8" projection, 39.5" AFF Protruding object with bottom between 27" and 80" AFF projects more than 4" from wall or 12" from post. 4.4.1; Fig. 8a-d
273 01 C-125 Counter in Security Lobby by Time Clock 8.5" projection, 39.25" AFF Protruding object with bottom between 27" and 80" AFF projects more than 4" from wall or 12" from post. 4.4.1; Fig. 8a-d
1087 05 000- Phone Public Pay Telephone No forward approach phone Two or more banks of public pay telephones on this floor. None meet the requirements for a forward reach telephone, where a minimum of 1 per floor is required. 4.1.3(17)(a)
1098 05 A-106 Concession Counter 41.5" AFF Sales, Service or Information Counter(s) or Teller Window(s) higher than 36" AFF or at Cash Register(s) for sales or distribution of goods or services 7.2
1099 05 A-107 Condiment Counter 14" projection, 34.75" AFF Protruding object with bottom between 27" and 80" AFF projects more than 4" from wall or 12" from post. Object is located along route of travel. 4.4.1; Fig. 8a-d
1100 05 A-107 Condiment Counter 42.25" AFF Sales, Service or Information Counter(s) or Teller Window(s) higher than 36" AFF or at Cash Register(s) for sales or distribution of goods or services to the public. 7.2
1109 05 B-106 Drinking Fountain 41" AFF Spout outlet higher than 36" AFF. 4.15.2
1110 05 B-106 Drinking Fountain 14# Controls require more than 5# force to operate. 4.15.4, 4.27.4
1111 05 B-107 Women's Toilet Room Visual alarm on ceiling Visual Signal(s) mounted at incorrect height. Visual signal is to be mounted at 80" AFF or 6" below ceiling (whichever is lower). 4.28.3(6)
1112 05 B-107 Women's Toilet Room No raised lettering and Braille, sign in arch greater than 60" centerline Existing room and/or gender identification signage is noncompliant. 4.1.3(16)(a), 4.30.4, 4.30.6
1113 05 B-107 Women's Toilet Room 10 stalls, 0 ambulatory If greater than or equal to 6, and if standard accessible stall provided, 36" wide ambulatory accessible stall also required. 4.1.3(11), 4.22.4; Fig. 30d
1114 05 B-107 Women's Toilet Room 40.5" wide Accessible stall width < 60" 4.1.3(11), 4.22.4, 4.17.3; Fig. 30a
1115 05 B-107 Women's Toilet Room 67.5" AFF Coat hook > 48" above finish floor front reach, or > 54"; side reach. 4.22.7, 4.27.3; Fig. 5, 6
1116 05 B-107 Women's Toilet Room 1.75" clear Grab bar-to-wall clearance < or > 1-1/2". 4.1.3(11), 4.22.4, 4.16.4, 4.17.6, 4.26.2; Fig. 39
1117 05 B-107 Women's Toilet Room No rear grab bars No rear grab bar (except at 36" alternate accessible stall). 4.1.3(11), 4.22.4, 4.16.4, 4.17.6; Fig. 29, 30
1118 05 B-107 Women's Toilet Room 19.5" AFF Top of water closet seat <17" or > 19" above finish floor. 4.1.3(11), 4.22.4, 4.16.3, 4.17.2; Fig. 29b, 30(d)
1119 05 B-107 Women's Toilet Room 20" centerline Centerline of water closet is < or > 18" from sidewall or partition. 4.1.3(11), 4.22.4, 4.17.3; Fig. 28, 30
1119.1 05 B-107 Women's Toilet Room door opposite toilet fixture Stall door is immediately opposite the water closet instead of diagonally opposite and within 4" from corner of stall. 4.1.3(11), 4.17.3, 4.22.4, Fig. 30
1120 05 B-107 Women's Toilet Room 13# Manual flush control at water closet requires > 5 lbs. of force to activate. 4.1.3(11), 4.22.4, 4.16.5, 4.17.2, 4.27.4
1121 05 B-107 Women's Toilet Room Large roll toilet paper Large roll toilet paper dispenser requires pinching and does not allow continuous delivery. 4.1.3(11), 4.22.4, 4.16.6, 4.17.2; Fig. 29b, 30(d)
1122 05 B-107 Women's Toilet Room No insulation Hot water pipes not insulated or covered. 4.1.3(11), 4.22.6, 4.19.4
1123 05 B-107 Women's Toilet Room 66.75" AFF Towel dispenser or blower outside reach range. 4.1.3(11), 4.22.7, 4.27.3; Fig. 4, 5, 6
1124 05 B-107 Women's Toilet Room 5" projection, 30" AFF Control or operating mechanism takes > 5 lbs. force to operate or requires tight gripping, grasping or twisting of wrist. Soap dispenser. 4.1.3(11), 4.22.7, 4.27.4
1125 05 B-107 Women's Toilet Room 13# Visual Signal(s) mounted at incorrect height. Visual signal is to be mounted at 80" AFF or 6" below ceiling (whichever is lower). 4.28.3(6)
1126 05 B-108 Men's Toilet Room Visual alarm on ceiling Visual Signal(s) mounted at incorrect height. Visual signal is to be mounted at 80" AFF or 6" below ceiling (whichever is lower). 4.28.3(6)
1127 05 B-108 Men's Toilet Room Sign in arch greater than 60" centerline, no raised lettering and Braille Existing room and/or gender identification signage is noncompliant. 4.1.3(16)(a), 4.30.4, 4.30.6
1128 05 B-108 Men's Toilet Room 41.5" wide Accessible stall width < 60". 4.1.3(11), 4.22.4, 4.17.3; Fig. 30a
1129 05 B-108 Men's Toilet Room No rear grab bar No rear grab bar (except at 36" alternate accessible stall). 4.1.3(11), 4.22.4, 4.16.4, 4.17.6; Fig. 29, 30
1130 05 B-108 Men's Toilet Room 20" centerline Centerline of water closet is < or > 18" from sidewall or partition. 4.1.3(11), 4.22.4, 4.16.2, 4.17.3; Fig. 28, 30
1130.1 05 B-108 Men's Toilet Room door opposite toilet fixture Stall door is immediately opposite the water closet instead of diagonally opposite and within 4" from corner of stall. 4.1.3(11), 4.17.3, 4.22.4, Fig. 30
1131 05 B-108 Men's Toilet Room 12# Manual flush control at water closet requires > 5 lbs. of force to activate 4.1.3(11), 4.22.4, 4.16.5, 4.17.2, 4.27.4
1132 05 B-108 Men's Toilet Room Large roll toilet paper Large roll toilet paper dispenser requires pinching and does not allow continuous delivery. 4.1.3(11), 4.22.4, 4.16.6, 4.17.2; Fig. 29b, 30(d)
1133 05 B-108 Men's Toilet Room 15# Manual flush control at urinal requires > five pounds force to activate. 4.1.3(11), 4.22.5, 4.18.4, 4.27.4
1134 05 B-108 Men's Toilet Room No insulation Hot water pipes not insulated or covered. 4.1.3(11), 4.22.6, 4.19.4
1135 05 B-108 Men's Toilet Room 67.5" AFF Towel dispenser or blower outside reach range. 4.1.3(11), 4.22.7, 4.27.3; Fig. 4, 5, 6
1136 05 B-108 Men's Toilet Room 5" projection, 30.75" AFF Protruding object with bottom between 27" and 80" above finish floor projects > 4" from wall into circulation path. Baby changing station. 4.4.1, 4.4.2; Fig. 8
1137 05 B-108 Men's Toilet Room 16# Control or operating mechanism takes > 5 lbs. force to operate or requires tight gripping, grasping or twisting of wrist. Soap dispenser. 4.1.3(11), 4.22.7, 4.27.4
1138 05 B-109 Corridor Doors 1.5 seconds Existing Closer causes Door to travel from 70 degrees open to 3" from latch in less than 3 sec. 4.13.10
1140 05 B-111 Box in Corridor 12.5" projection, 65" AFF Protruding object with bottom between 27" and 80" AFF projects more than 4" from wall or 12" from post. 4.4.1; Fig. 8a-d
1146 05 B-117 Fire Pull at Column 29 63" AFF Control outside reach range. 4.1.3(13), 4.27.3; Fig. 5, 6
1644 05 D-116 Lighted Sign 5.5" projection, 34.5" AFF Protruding object with bottom between 27" and 80" AFF projects more than 4" from wall or 12" from post. 4.4.1; Fig. 8a-d
1645 05 D-117 Public Pay Telephone No outlet Bank of 3 or more phones: None have shelf or outlet for portable TTY. 4.1.3(17)(d)
1646 05 D-117 Public Pay Telephone 65" AFF Operable parts of phone outside reach range. Three public pay telephones, none accessible. 4.1.3(17), 4.31.3; Fig. 5, 6, 44a-b
1647 05 D-117 Public Pay Telephone No volume control Accessible telephone does not have volume control. 4.1.3(17)(b)
1648 05 D-117 Public Pay Telephone Grasping and twisting Push button controls are required: Operable part of telephone requires grasping or twisting to operate 4.31.6
1650 05 D-118 Lobby Doors 2 seconds Existing Closer causes Door to travel from 70 degrees open to 3" from latch in less than 3 sec. 4.13.10
1661.1 05 D-125 Women's Toilet Room No directional signage No directional signage to nearest accessible toilet room at inaccessible toilet room. 4.1.6(3)(e)(iii)
1665 05 D-125 Women's Toilet Room Visual alarm on ceiling Visual Signal(s) mounted at incorrect height. Visual signal is to be mounted at 80" AFF or 6" below ceiling (whichever is lower). 4.28.3(6)
1666 05 D-125 Women's Toilet Room No raised lettering and Braille, sign suspended from ceiling Existing room and/or gender identification signage is noncompliant. MSG will provide directional signage to the nearest accessible restroom. 4.1.3(16)(a), 4.30.4, 4.30.6
1681.1 05 D-126 Men's Toilet Room Inaccessible; no directional signage No directional signage to nearest accessible toilet room at inaccessible toilet room. .1.6(3)(e)(iii)
1683 05 D-126 Men's Toilet Room Visual alarm on ceiling Visual Signal(s) mounted at incorrect height. Visual signal is to be mounted at 80" AFF or 6" below ceiling (whichever is lower). 4.28.3(6)
1684 05 D-126 Men's Toilet Room Sign on door, no raised lettering and Braille Existing room and/or gender identification signage is noncompliant. MSG will provide directional signage to the nearest accessible restroom. 4.1.3(16)(a), 4.30.4, 4.30.6
1702.1 05 D-127 Men's Toilet Room Inaccessible; no directional signage No directional signage to nearest accessible toilet room at inaccessible toilet room. 4.1.6(3)(e)(iii)
1705 05 D-127 Men's Toilet Room Visual alarm on ceiling Visual Signal(s) mounted at incorrect height. Visual signal is to be mounted at 80" AFF or 6" below ceiling (whichever is lower). 4.28.3(6)
1706 05 D-127 Men's Toilet Room No raised lettering and Braille, sign suspended from ceiling Existing room and/or gender identification signage is noncompliant. MSG will provide directional signage to the nearest accessible restroom. 4.1.3(16)(a), 4.30.4, 4.30.6
1723.1 05 D-128 Women's Toilet Room Inaccessible; no directional signage No directional signage to nearest accessible toilet room at inaccessible toilet room. 4.1.6(3)(e)(iii)
1726 05 D-128 Women's Toilet Room Visual alarm on ceiling Visual Signal(s) mounted at incorrect height. Visual signal is to be mounted at 80" AFF or 6" below ceiling (whichever is lower). MSG will provide directional signage to the nearest accessible restroom. 4.28.3(6)
1727 05 D-128 Women's Toilet Room Sign on door, no raised lettering and Braille Existing room and/or gender identification signage is noncompliant. MSG will provide directional signage to the nearest accessible restroom. 4.1.3(16)(a), 4.30.4, 4.30.6
1746 05 D-132 Gift and Souvenir Counter 41.5" AFF Sales, Service or Information Counter(s) or Teller Window(s) higher than 36" AFF or at Cash Register(s) for sales or distribution of goods or services to the public. 7.2
1747 05 D-133 Concession Counter 42" AFF Sales, Service or Information Counter(s) or Teller Window(s) higher than 36" AFF or at Cash Register(s) for sales or distribution of goods or services to the public. 7.2
1748 05 D-134 Condiment Counter 14" projection, 35" AFF Protruding object with bottom between 27" and 80" AFF projects more than 4" from wall or 12" from post. 4.4.1; Fig. 8a-d
1749 05 D-134 Condiment Counter 42.25" AFF Sales, Service or Information Counter(s) or Teller Window(s) higher than 36" AFF or at Cash Register(s) for sales or distribution of goods or services to the public. 7.2
1750 05 D-135 Lighted Sign 5.5" projection, 33.25" AFF Protruding object with bottom between 27" and 80" AFF projects more than 4" from wall or 12" from post. 4.4.1; Fig. 8a-d
1808 05 D-145 Visual Alarm in Corridor Visual alarm on ceiling Visual Signal(s) mounted at incorrect height. Visual signal is to be mounted at 80" AFF or 6" below ceiling (whichever is lower). 4.28.3(6)
1809 05 D-146 Visual Alarm in Corridor Visual alarm on ceiling Visual Signal(s) mounted at incorrect height. Visual signal is to be mounted at 80" AFF or 6" below ceiling (whichever is lower). 4.28.3(6)
1810 05 D-147 Visual Alarm in Corridor (by Gate #52) Visual alarm on ceiling Visual Signal(s) mounted at incorrect height. Visual signal is to be mounted at 80" AFF or 6" below ceiling (whichever is lower). 4.28.3(6)
1812 05 D-149 Fire Pull at Column 7 (located across from elevator) 63" AFF Control outside reach range. 4.1.3(13), 4.27.3; Fig. 5, 6
3117 05 B-107 Women's Toilet Room 32.5" AFF The height from the centerline of grab bar(s) to finish floor is < 33" or > 36". 4.1.3(11), 4.22.4, 4.16.4, 4.17.6; Fig. 29, 30
3118 05 B-108 Men's Toilet Room 32.75" AFF The height from the centerline of grab bar(s) to finish floor is < 33" or > 36". 4.1.3(11), 4.22.4, 4.16.4, 4.17.6; Fig. 29, 30



Return to settlement