ATTACHMENT I: Modifications to Newly Constructed FacilitiesThe chart below lists the facilities surveyed by the Department, the access issues identified during the survey, and the actions required to correct the access issues. Required actions are listed using an alphanumeric code. The key to the alphanumeric codes is provided in Attachment M to this Agreement. In order to ensure that the following spaces and elements in County facilities for which construction was commenced after January 26, 1992, are readily accessible to and usable by persons with disabilities, the County will take the actions referenced by the alphanumeric code and described in detail in Attachment M to this Settlement Agreement within the time periods specified below, which time periods will begin to run on the effective date of this Agreement. | |||
Item # | Access Issue | Required Action | Completion Date |
1. | LUMPKIN COUNTY JUSTICE CENTER, 365 Riley Road, Dahlonega, Georgia 30533 | ||
1.1. |
Accessible route: The curb ramp is inaccessible because detectable warning does not extend the full width and depth of the ramp. | AR4 | 30 months |
1.2. |
Entrance ramp: The ramp is not accessible because the handrails are 2 1/2 inches from the wall at the bottom, 5 1/2 inches from the wall in the middle and 8 inches from the wall at the top. | R2 | 30 months |
1.2.1. |
The ramp is inaccessible because it has no edge protection at the drop off sides. | R3 | 30 months |
1.2.2. |
The interior route is inaccessible because the security screening device is only 28 inches wide. | AR3 | 30 months |
1.3. | Lobby Sheriffs' Office Counter | ||
1.3.1 | The counter is inaccessible because it is 42 inches high. | C1 | 30 months |
1.4. | Superior Court Clerk Room #108 | ||
1.4.1. | The counter is inaccessible because it is 42 inches high. | C1 | 30 months |
1.5. | Superior Court Record Room | ||
1.5.1. | The route to the stacks is inaccessible because it is only 24 inches wide. | AR3 | 30 months |
1.5.2. | The route directly in front of the work table has inadequate clear floor space. | AR10 | 30 months |
1.5.3. | The book stacks are inaccessible because the width between stacks is only 31 inches. | AR3 | 30 months |
1.5.4. | The newly installed books stacks are inaccessible because there is a 2 inch threshold. | AR1 | 30 months |
1.6. | Women's Toilet Room-1st Floor Lobby-Stalls | ||
1.6.1. | The door inaccessible because it requires 11 pounds of force to open. | D3 | 30 months |
1.6.2. | The lavatory is inaccessible because the bottom of the apron is 28 inches high. | LS3 | 30 months |
1.6.3. | No accessible coat hook has been provided. | TR3 | 30 months |
1.7. | Men's Toilet Room-1st Floor Lobby-1 stall, 2 urinals | ||
1.7.1. | The door is inaccessible because it requires 11 pounds of force to open. | D3 | 30 months |
1.7.2. | The lavatory is inaccessible because the bottom of the apron is 28 inches high. | LS3 | 30 months |
1.7.3. | No accessible coat hook has been provided. | TR3 | 30 months |
1.8. | Single User Toilet Room-1st Floor-Magistrate Court Clerk-Employees | ||
1.8.1. | The door inaccessible because it requires 10 pounds of force to open. | D3 | 30 months |
1.9. | Single User Toilet Room-1st Floor-Probate Court Clerk | ||
1.9.1. | The door is inaccessible because it requires 10 pounds of force to open. | D3 | 30 months |
1.10. | Magistrate Court Room-1st Floor | ||
1.10.1. | The judge's bench is inaccessible because it can be only be accessed by 6 inch steps. | AA8 | 30 months |
1.10.2. | Juvenile Court, Grand Jury, 2nd Floor | ||
1.10.3. | The judge's bench is inaccessible because it can be accessible only by 6 inch steps. | AA8 | 30 months |
1.11. | Superior Court A, 2nd Floor | ||
1.11.1. | The judge's bench is inaccessible because it can be only be accessed by 6 inch steps. | AA8 | 30 months |
1.12. | Superior Court B, 2nd Floor | ||
1.12.1. | The judge's bench is inaccessible because it can only be accessed by 6 inch steps. | AA8 | 30 months |
1.13. | Single User Toilet Room-2nd Floor-Superior Court-Employees-East | ||
1.13.1. | The door is inaccessible because it requires 10 pounds of force to open. | D3 | 30 months |
1.13.2 | The lavatory is inaccessible because the bottom of the apron is 28 inches high. | LS3 | 30 months |
1.14. | Single User Toilet Room-2nd Floor-Superior Court-Employees-West | ||
1.14.1. | The door is inaccessible because it requires 10 pounds of force to open. | D3 | 30 months |
1.14.2. | The lavatory is inaccessible because the bottom of the apron is 28 inches high. | LS3 | 30 months |
1.15. | Elevators throughout facility | ||
1.15.1 | The elevator is inaccessible because the emergency system requires voice communication to operate. (System did not recognize silent call during on-site test) | E7 | 30 months |
1.16. | Men's Toilet Room-1st Floor Lobby-1 stall, 2 urinals | ||
1.16.1 |
The door is inaccessible because it requires 10 pounds of force to open. | D3 | 30 months |
1.16.2 | The urinal is inaccessible because the clear floor space is 27"W by 30" D. | TR8 | 30 months |
2. | LUMPKIN COUNTY MENTAL HEALTH CENTER, 155 Johnston St, Dahlonega, Georgia 30533 | ||
2.1.1. | The curb ramp is inaccessible because it has a slope of 14.7%. | R1 | 30 months |
2.2. | Main Counter | ||
2.2.1. | The counter is inaccessible because it is 42 inches high. | C1 | 30 months |
2.3. | Single User Toilet Room-Near Vending Machine | ||
2.3.1. | Although an audible alarm is provided in this facility, there is no visual alarm appliance in the toilet room. | AL1 | 30 months |
2.3.2. | The toilet is inaccessible because the centerline is 20 1/2 inches from the side wall. | TR7 | 30 months |
2.3.3. | The toilet is inaccessible because the flush control is on the closed side. | TR4 | 30 months |
2.3.4. | The toilet is inaccessible because the rear grab bar is 24 inches long and 8 inches from the side wall. | TR13 | 30 months |
2.3.5. | The toilet is inaccessible because the side grab bar is 32 inches from the far end of the side wall. | TR16 | 12 months |
2.4. | Single User Toilet Room-Near Main Entrance | ||
2.4.1. | Although an audible alarm is provided in this facility, there is no visual alarm appliance in the toilet room. | AL1 | 30 months |
2.4.2. | The toilet is inaccessible because the flush control is on the closed side. | TR7 | 30 months |
2.4.3. | The toilet is inaccessible because the rear grab bar is 24 inches long and 8 inches from the side wall. | TR13 | 30 months |
2.4.4. | The toilet is inaccessible because the side grab bar is 46 inches from the rear wall. | TR16 | 30 months |
2.5. | Single User Toilet Room-Across from Room 124 | ||
2.5.1. | The door is inaccessible because it requires 7 pounds of force to open. | D3 | 12 months |
2.5.2. | Although an audible alarm is provided in this facility, there is no visual alarm appliance in the toilet room. | AL1 | 30 months |
2.5.3. | The toilet is inaccessible because the top of the seat is 16 inches high. | TR9 | 30 months |
2.5.4. | The toilet is inaccessible because the centerline is 18 1/2 inches from the side wall. | TR7 | 30 months |
2.5.5. | The toilet is inaccessible because there are no grab bars provided. | TR1 | 12 months |
3. | TIMKEN COMMUNITY PAVILION, 1166 Captain McDonald Road, Dahlonega, Georgia 30533 | ||
3.1. | Women's Toilet Room-Stalls | ||
3.1.1. | The toilet room sign is mounted on the door. | TR11 | 12 months |
3.1.2. | No accessible coat hook has been provided. |
TR3 | 12 months |
3.2. | Men's Toilet Room-Stalls | ||
3.2.1 | The toilet room sign is mounted on the door. | TR11 | 12 months |
3.2.2. | The designated accessible toilet is inaccessible because the flush control is on the closed side. | TR4 | 30 months |
3.2.3. | No accessible coat hook has been provided. | TR3 | 12 months |
3.3. | Counter Across From Toilet Room | ||
3.3.1. | The counter is inaccessible because it is 42 inches high. | C1 | 30 months |
3.4. | Play Ground Equipment/Picnic Tables | ||
3.4.1. | The route to the playground equipment is inaccessible because it has a gravel surface and is not firm and slip resistant. | AR1 | 30 months |
3.4.2. | The route to the swings is inaccessible because it is not firm or slip resistant. | AR1 | 30 months |
3.4.3. | The route to the picnic tables is inaccessible because it is not firm or slip resistant. | AR1 | 30 months |
4. | LUMPKIN COUNTY LAW ENFORCEMENT CENTER, 385 N Main Street, Dahlonega, Georgia 30533 | ||
4.1. | Parking: The parking lot, with a total of 21 parking spaces, is inaccessible because the designated accessible parallel parking spaces lack vertical van-accessible signage. | P3 | 12 months |
4.1.1. | The accessible parking space is inaccessible because the access aisle encroaches into the space. | P2 | 12 months |
4.2. | Accessible Cell F1, C Pod and D Pod | ||
4.2.1. | There is no accessible cell provided. | PJ1 | 30 months |
4.3. | Women's Single User Toilet Room-Lobby | ||
4.3.1. | The door is inaccessible because it requires 10 pounds of force to open. | D3 | 12 months |
4.3.2. | The paper towel dispenser is inaccessible because the controls require twisting of the wrist to operate. | CT2 | 12 months |
4.4. | Men's Single User Toilet Room-Lobby | ||
4.4.1. | The door is inaccessible because the pressure required to open the door is 10 pounds. | D3 | 12 months |
4.4.2. | The paper towel dispenser is inaccessible because the controls require twisting of the wrist to operate. | CT2 | 12 months |
5. | LUMPKIN COUNTY HEALTH DEPARTMENT, 60 Mechanicsville Road, Dahlonega, Georgia 30533 | ||
5.1. | Main Check-In/Check-out Counters | ||
5.1.1. | The main counters are inaccessible because it is 39 inches high. | C1 | 30 months |
5.2. | Unisex Toilet Room-East and West | ||
5.2.1. | The toilet in both toilet rooms is inaccessible because there is insufficient clear floor space. | AR10 | 30 months |
5.3. | WIC Interior door | ||
5.3.1. | The door is inaccessible because it requires 10 pounds of force to open. | D3 | 30 months |
5.4. | WIC Pamphlet Display | ||
5.4.1. | The pamphlet displays are inaccessible because they are 82 inches high. | AR3 | 30 months |
5.5. | Unisex Toilet Room and Shower- Employee Break Room | ||
5.5.1. | The toilet is inaccessible because the centerline is 19 inches from the side wall. | TR7 | 12 months |
5.5.2. | There is no accessible shower provided. | B2 | 12 months |
6. | ANIMAL SHELTER, 1363 Red Oaks Flat Road, Dahlonega, Georgia 30533 | ||
6.1. | Parking: The designated accessible parking is inaccessible because it slope exceeds 2% and it has a cross slope that exceeds 2%. | P4 | 12 months |
6.2. | Entrance ramp | ||
6.2.1. | The ramp is inaccessible because there is no handrail on the middle inside of the side of the ramp segment. | R2 | 12 months |
6.2.2. | The ramp is inaccessible because there is no 12 inch extension at the top and bottom of the ramp parallel with the ground surface. | R2 | 12 months |
6.3. | Main Counter | ||
6.3.1. | The main counters are inaccessible because it is 42 inches high. | C1 | 30 months |
6.4. | Interior Door ( Isolation room) | ||
6.4.1 | The door is inaccessible because knob hardware is used. | D2 | 12 months |
6.4.2. | The door is inaccessible because it has an opening width of only 28 inches. | D14 | 30 months |
6.5. | Interior Door (Visitation room) | ||
6.5.1. | The door is inaccessible because knob hardware is used. | D2 | 12 months |
6.5.2. | The route to the visitation room is inaccessible because there are three stairs. | AR2 | 30 months |
6.6. | Single User Toilet Room/Lobby | ||
6.6.1. | The toilet room sign is mounted on the door and has no raised or Braille characters. | TR11 | 12 months |
6.6.2. | The paper towel dispenser is inaccessible because the controls require twisting of the wrist to operate. | CT2 | 12 months |
6.6.3. | The lavatory is inaccessible because it has no knee, toe clearances. | LS3 | 30 months |
6.6.4. | The toilet is inaccessible because the flush control is on the closed side. | TR4 | 30 months |
6.6.5. | The toilet is inaccessible because the side grab bar is 24 inches long. | TR17 | 12 months |
6.7. | Back Ramp from Isolation Room to Kennels | ||
6.7.1. | The ramp is inaccessible because it slopes up to 16.9%. | R4 | 30 months |
6.7.2. | The handrails are inaccessible because there is no handrail on the middle inside of the side of the ramp segment. | R2 | 30 months |
6.7.3. | The handrails are inaccessible because there is no 12 inch extension at the top and bottom of the ramp parallel with the ground surface. | R2 | 30 months |
|
POOL CONCESSION, 56, Mechanicsville Road, Dahlonega, Georgia 30533 | ||
7.1. | Accessible Route From Parking to Picnic Pavilion | ||
7.1.1. | The route is inaccessible because it is only 29 inches wide and does not have adequate passing space. | AR3 | 12 months |
7.1.2. | The route is inaccessible because the surface is not level. | AR1 | 12 months |
7.1.3. | The picnic tables are inaccessible because none provide adequate knee space at least 27 inches high, 30 inches wide and 19 inches deep. | DW1 | 12 months |
7.2. | Accessible Route to Pool Concession Employees Entrance | ||
7.2.1. | The door is inaccessible because there is a 3 inch high threshold. | D1 | 12 months |
7.3. | Pool Concession Counter | ||
7.3.1. | The counter is inaccessible because it is 48.5 inches high. | C1 | 12 months |
7.4. | Women's (Girls) Toilet Room with Stalls | ||
7.4.1. | The toilet room sign is mounted on the door and has no raised or Braille characters. | TR11 | 12 months |
7.4.2. | The door is inaccessible because there is a 4.5 inch high threshold. | D12 | 12 months |
7.4.3. | The door is inaccessible because the hardware requires tight grasping, twisting or pinching of the wrist to operate. | D2 | 12 months |
7.4.4. | The door is inaccessible because it has only 18 inches on the pull side of the door. | D5 | 12 months |
7.4.5. | The light switch is inaccessible because it is mounted with controls 61.5 inches above the finished floor. | CT4 | 12 months |
7.4.6. | Although an audible alarm is provided in this facility, there is no visual alarm appliance in the toilet room. | AL1 | 12 months |
7.4.7. | The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact. | LS2 | 12 months |
7.4.8. | The lavatory is inaccessible because the hardware requires tight grasping, twisting or pinching of the wrist to operate. | LS4 | 12 months |
7.4.9. | The toilet paper dispenser in the designated accessible stall is inaccessible because it mounted above the side grab bar. | TR6 | 12 months |
7.4.10. | No accessible coat hooks are provided. | TR3 | 12 months |
7.4.11. | There is no accessible locker provided. | LR3 | 12 months |
7.4.12. | There is no accessible shower provided. | B2 | 12 months |
7.4.13. | The shower head protrudes into the accessible route and is not detectable to blind persons using a cane. | AR7 | 12 months |
7.5. | Men's (Boys) Toilet Room with Stalls | ||
7.5.1 | The toilet room sign is mounted on the door and has no raised or Braille characters. | TR11 | 12 months |
7.5.2. | The door is inaccessible because there is a 4 1/2 inch high threshold. | D12 | 12 months |
7.5.3. | The light switch is inaccessible because it is mounted 61 1/2 inches above the finished floor. | CT4 | 12 months |
7.5.4. | Although an audible alarm is provided in this facility, there is no visual alarm appliance in the toilet room. | AL1 | 12 months |
7.5.5. | The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact. | LS2 | 12 months |
7.5.6. | The toilet paper dispenser in the designated accessible stall is inaccessible because it mounted 57 inches above the grab bars. | CT4 | 12 months |
7.5.7. |
No accessible coat hooks are provided. | TR3 | 12 months |
7.5.8. |
There is no accessible locker provided. | LR3 | 12 months |
7.5.9. |
There is no accessible shower provided. | B2 | 12 months |
7.5.10. |
The shower head protrudes into the accessible route and is not detectable to blind persons using a cane. | AR7 | 12 months |