ATTACHMENT K: Program Access in Existing Facilities

Please Note: Paragraph 54 of the Agreement requires that within nine months of the effective date of this Agreement, the City of Jacksonville will provide signage as necessary to comply with 28 C.F.R. § 35.163(b), after having surveyed all facilities that are the subject of this Agreement for the purpose of identifying those that have multiple entrances not all of which are accessible. The technical requirements and, where appropriate, the scoping requirements of the Standards are used as a guide for determining whether a program or activity held in an existing facility is “readily accessible to and usable by” persons with disabilities and for determining what changes are necessary to make this program or activity accessible if it continues to be provided in the existing facility in question. See 28 C.F.R. §§ 35.150(b)(1), 35.151.

The chart below lists the facilities surveyed by the Department, the access issues identified during the survey, and the actions required to correct the access issues. Required actions are listed using an alphanumeric code. The key to the alphanumeric codes is provided in Attachment M to this Agreement.

In order to ensure that the programs, services, and activities housed in the City of Jacksonville facilities are accessible to persons with disabilities, when viewed in their entirety, the City of Jacksonville will take the actions referenced by the alphanumeric code and described in detail in Attachment M to this Settlement Agreement within the time period specified below, which time period begins to run on the effective date of the Agreement.

Item # Access Issue Required Action Completion Date
1. IM Sulzbacher Shelter, 611 Adams Street
1.1 Entrance ramp: The ramp is inaccessible because it has a slope between 8.9% and 10.2% and the handrails lack extensions. R3 36 months
1.2 Dorms:    
1.2.a The facility is inaccessible because no accessible sleeping rooms are provided. A total of 2 accessible rooms is required. L1 12 months
1.2.b The lift to the 2nd floor is inaccessible because it requires that a key be obtained from an employee before the lift can be operated. LF2 12 months
1.3 Single-user unisex toilet room in lobby:    
1.3.a The toilet room sign is mounted on the door and has no raised or Braille characters. TR11 12 months
1.3.b The door is inaccessible because it requires 12 pounds of force to open. D12 12 months
1.3.c The push side of the door, which is accessed through a front approach and which has both a closer and a latch, is inaccessible because it has only 2 inches of clear space on the latch side. D5 24 months
1.3.d The toilet room is inaccessible because there is insufficient turning space provided within the room. TR21 24 months
1.3.e Main Women / Family area: The telephones and a box on the wall in the main area protrude into the walkway and are not detectable to blind persons using a cane. AR7 24 months
1.4 Single-user unisex toilet rooms in main Women / Family area:    
1.4.a The toilet room signs are mounted on the door and have no raised or Braille characters. LS3 12 months
1.4.b The doors are inaccessible because they require 9 pounds of force to open. D12 24 months
1.4.c The push side of each door, which is accessed through a front approach and which has both a closer and a latch, is inaccessible because it has only 6 inches of clear space on the latch side. D5 24 months
1.4.d Although an audible alarm is provided in this facility, there is no visual alarm appliance in either toilet room. AL1 36 months
1.4.e No accessible coat hook has been provided in either room. TR3 12 months
1.4.f The soap dispensers are inaccessible because they are mounted 53 inches high above the lavatory. CT3 12 months
1.4.g The paper towel dispensers are inaccessible because they are mounted with the controls 51 inches high. CT4 12 months
1.4.h One of the toilets is inaccessible because the flush control is on the closed side. TR4 24 months
1.4.i The toilets are inaccessible because the side grab bars are obstructed by the toilet paper dispensers. TR15 12 months
1.4.j The rear grab bars at the toilets are inaccessible because they are obstructed by the toilet flush valve. TR15 12 months
1.5 Drinking fountain in main Women / Family area:    
1.5.a The drinking fountain is inaccessible because it has a spout that is 39 1/2 inches high. DF3 24 months
1.5.b The drinking fountain is inaccessible because its control requires 10 pounds of force to operate. DF2 24 months
1.6 Women’s locker room in Women / Family area:    
1.6.a The toilet room sign is mounted on the door and has no raised or Braille characters. LS3 12 months
1.6.b The door is inaccessible because it requires 8 pounds of force to open. D3 12 months
1.6.c No accessible coat hook has been provided. TR3 12 months
1.6.d The side grab bar at the designated accessible toilet is inaccessible because it is obstructed by the toilet paper dispenser. TR15 12 months
1.6.e There is no accessible shower provided. B2 24 months
1.6.f The shelf in the shower protrudes into the walkway and is not detectable to blind persons using a cane. AR7 24 months
1.7 Men’s locker room in Women / Family area:    
1.7.a The toilet room sign is mounted on the door and has no raised or Braille characters. LS3 12 months
1.7.b The door is inaccessible because it requires 14 pounds of force to open. D3 12 months
1.7.c No accessible coat hook has been provided. TR3 12 months
1.7.d There is no accessible shower provided. B2 24 months
1.7.e The shelf in the shower protrudes into the walkway and is not detectable to blind persons using a cane. AR7 24 months
1.8 Women / Family area side patio:    
1.8.a The exterior stairway creates an overhead hazard that is not detectable to blind persons using a cane. AR6 36 months
1.8.b The picnic tables are inaccessible because none provide the required knee space. DW1 24 months
1.8.c The route to the playground is inaccessible because the dirt is not firm, stable, and slip-resistant and there is a step up onto the playground surface. AR1 36 months
1.8.d The cement ramp along the wall to the patio is inaccessible because it lacks edge protection, one handrail does not extend the entire length of the ramp, the handrails lack extensions, and the diameter of the handrails is 1 3/4 inches. R1 36 months
1.8.e The wooden ramp to the patio is inaccessible because it lacks handrails. R3 24 months
1.9 North side Women / Singles entrance: The door is inaccessible because it requires 8 pounds of force to open. D3 12 months
1.10 North Women / Singles / Families Common Room:    
1.10.a The door is inaccessible because knob hardware is used. D2 12 months
1.10.b The telephone is inaccessible because it lacks volume control. TT1 24 months
1.11 Locker room for north Women / Singles / Families bedrooms:    
1.11.a The door is inaccessible because it requires 14 pounds of force to open. D3 12 months
1.11.b The baby changing table is inaccessible because it is mounted with the controls 63 inches high. CT4 12 months
1.11.c No accessible coat hook has been provided. TR3 12 months
1.11.d The roll-in shower is not accessible because there are grab bars on only 2 walls, and the controls are 55 inches high. B2 24 months
1.11.e The shelf in the shower protrudes into the walkway and is not detectable to blind persons using a cane. AR7 24 months
1.12 South side Women / Singles entrance:    
1.12.a The doors are inaccessible because they require 11 pounds and 15 pounds of force to open. D3 12 months
1.12.b The exterior door is inaccessible because knob hardware is used. D2 12 months
1.12.c The push side of the exterior door, which is accessed through a front approach and which has both a closer and a latch, is inaccessible because it has only 9 inches of clear space on the latch side. D5 24 months
1.13 South Women / Singles common area: The telephone is inaccessible because it lacks volume control. TT1 24 months
1.14 South Women / Singles side patio: The push side of the door, which is accessed through a front approach and which has both a closer and a latch, is inaccessible because it has only 11 inches of clear space on the latch side. D5 24 months
1.15 South Women / Singles / Families locker room:    
1.15.a The toilet room sign is inaccessible. TR11 12 months
1.15.b The entrance door is inaccessible because it requires 6 pounds of force to open. D3 12 months
1.15.c The pull side of the door, which is accessed through a front approach, is inaccessible because it has only 14 inches of clear space on the latch side. D5 24 months
1.15.d The designated accessible toilet is inaccessible because the flush control is on the closed side. TR4 24 months
1.15.e No accessible coat hook has been provided. TR3 12 months
1.15.f The roll-in shower is inaccessible because the controls are 56 inches high. B2 24 months
1.16 Case manager’s office: The door is inaccessible because knob hardware is used. D3 12 months
1.17 Dining hall:    
1.17.a The pull side of the door, which is accessed through a front approach, is inaccessible because it has only 9 inches of clear space on the latch side. D5 24 months
1.17.b The food distribution counter is inaccessible because it is 41 1/2 inches high. DW1 24 months
1.18 Single user toilet rooms with baths on second floor (rooms 212 and 210/211):    
1.18.a The toilet room signs are mounted on the doors. TR11 12 months
1.18.b The doors are inaccessible because they require 12 pounds of force to open. D3 12 months
1.18.c Although an audible alarm is provided in this facility, there is no visual alarm appliance in either toilet room. AL1 36 months
1.18.d The lavatories are inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact. LS2 12 months
1.18.e The toilets are inaccessible because the top of the seat is 16 inches high. TR9 36 months
1.18.f The toilet in room 210/211 is inaccessible because the flush control is on the closed side. TR4 24 months
1.18.g The bathtubs are inaccessible because no seat is provided, the showerhead cannot be handheld, the clear floor space is 25 inches wide, and the grab bars at the heads of each bathtub are 12 inches long. B1 24 months
1.19 Men’s pavilion:    
1.19.a The drinking fountain protrudes into the walkway and is not detectable to blind persons using a cane. AR7 24 months
1.19.b Although a designated accessible drinking fountain is provided, there is no drinking fountain provided for people who have difficult bending or stooping. DF3 12 months
1.19.c The picnic tables are inaccessible because none provide the required knee space. DW1 24 months
1.20 Men’s common area:    
1.20.a The entry door is inaccessible because it requires 15 pounds of force to open. D3 12 months
1.20.b The drinking fountain is inaccessible because the controls require 10 pounds of force to operate. DF2 24 months
1.21 Men’s locker room:    
1.21.a The toilet room sign is inaccessible. TR11 12 months
1.21.b The entry door is inaccessible because it requires 15 pounds of force to open. D3 12 months
1.21.c No accessible mirror has been provided. TR5 12 months
1.21.d The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact. LS2 12 months
1.21.e There is no accessible toilet stall provided. TR2 24 months
1.21.f The roll-in shower is not accessible because there are no grab bars, and the controls are 55 inches high. B2 24 months
2. Oceanway Park, 12215 Sago Avenue
2.1 Route from pool to playground: The route is inaccessible because it has a cross-slope of 6.3%. AR1 36 months
2.2 Exterior playground drinking fountain:    
2.2.a The drinking fountain is inaccessible because the controls require 12 pounds of force to operate. DF2 24 months
2.2.b Although a designated accessible drinking fountain is provided, there is no drinking fountain provided for people who have difficulty bending or stooping. DF3 12 months
2.3 Ramp to the dock: The ramp is inaccessible because there are no handrails provided. R3 24 months
2.4 Route from parking to tennis courts: The route is inaccessible because the surface is not firm, stable, and slip-resistant due to sand. AR1 36 months
2.5 Tennis court:    
2.5.a The entryway onto the tennis court is inaccessible because it has an opening width of 34 inches for a length of more than 24 inches, and there is a portion that is 27 inches wide. AR3 12 months
2.5.b The entrance door is inaccessible because it has an opening width of 29 inches. D14 24 months
2.6 Route to ballfield: The route is inaccessible because the sand and grass are not firm, stable, and slip-resistant. AR1 36 months
2.7 Ballfield bleachers: The bleachers are inaccessible because there is no wheelchair seating area provided. AA6 36 months
2.8 Drinking fountain near toilet room by ballfield:    
2.8.a The drinking fountain is inaccessible because the controls require 15 pounds of force to operate. DF2 24 months
2.8.b Although a designated accessible drinking fountain is provided, there is no drinking fountain provided for people who have difficulty bending or stooping. DF3 12 months
2.9 Route to basketball court and swings: The route is inaccessible because the sand and grass are not firm, stable, and slip-resistant. AR1 36 months
2.10 Men’s toilet room by picnic pavilion:    
2.10.a The toilet room sign is mounted on the door and has no raised or Braille characters. TR11 12 months
2.10.b The urinal is inaccessible because the rim is 22 inches high. TR8 36 months
2.10.c The designated accessible toilet is inaccessible because the flush control is on the closed side. TR4 24 months
2.10.d No accessible coat hook has been provided. TR3 12 months
2.10.e The side grab bar at the designated accessible toilet is inaccessible because it is mounted with the far end 48 inches from the rear wall. TR16 12 months
2.10.f The rear grab bar at the designated accessible toilet is inaccessible because it is 24 inches long. TR14 12 months
2.11 Women’s toilet room by picnic pavilion:    
2.11.a The toilet room sign is mounted on the door and has no raised or Braille characters. TR11 12 months
2.11.b The lavatory is inaccessible because it has twist-type hardware. LS4 24 months
2.11.c The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact. LS2 12 months
2.11.d No accessible coat hook has been provided. TR3 12 months
2.11.e The side grab bar at the designated accessible toilet is inaccessible because it is mounted with the far end 48 inches from the rear wall. TR16 12 months
2.11.f The rear grab bar at the designated accessible toilet is inaccessible because it is 24 inches long. TR14 12 months
3. Oceanway Community Center, 12215 Sago Avenue
3.1 Route past office 3: The fire extinguisher outside Office 3 protrudes into the walkway and is not detectable to blind persons using a cane. AR7 24 months
3.2 Main area: The doors in the main area are inaccessible because knob hardware is used. D2 12 months
3.3 Women’s toilet room with stalls:    
3.3.a The toilet room sign is mounted on the door. TR11 12 months
3.3.b The doors are inaccessible because they require 10 and 11 pounds of force to open. D3 12 months
3.3.c The entrance to the toilet room is inaccessible because the vestibule is not sufficiently deep. D4 12 months
3.3.d Although an audible alarm is provided in this facility, there is no visual alarm appliance in the toilet room. AL1 36 months
3.3.e No accessible mirror has been provided. TR5 12 months
3.3.f The soap dispenser is inaccessible because it is mounted with the controls 56 inches high. CT4 12 months
3.3.g The lavatory is inaccessible because the top of the rim or counter is 35 1/2 inches high. LS3 36 months
3.3.h The toilet paper dispenser in the designated accessible stall is inaccessible because it is mounted on the far wall. TR6 12 months
3.3.i The side grab bar at the designated accessible toilet is inaccessible because it is mounted with the far end 44 inches from the rear wall. TR17 12 months
3.3.j The rear grab bar at the designated accessible toilet is inaccessible because it is 18 inches long and it is mounted 9 inches from the side wall. TR14 12 months
3.4 Men’s toilet room:    
3.4.a The toilet room sign is mounted on the door. TR11 12 months
3.4.b The doors are inaccessible because they each require 11 pounds of force to open. D3 12 months
3.4.c The entrance to the toilet room is inaccessible because the vestibule is not sufficiently deep. D4 12 months
3.4.d Although an audible alarm is provided in this facility, there is no visual alarm appliance in the toilet room. AL1 36 months
3.4.e No accessible mirror has been provided. TR5 12 months
3.4.f The soap dispenser is inaccessible because it is mounted with the controls 58 inches high. CT4 12 months
3.4.g The lavatory is inaccessible because the top of the rim or counter is 36 inches high. LS3 36 months
3.4.h The urinal is inaccessible because the rim is 23 inches high and the flush control is 51 inches high. TR8 36 months
3.4.i The designated accessible toilet is inaccessible because the top of the seat is not between 17 and 19 inches high. TR9 24 months
3.4.j The designated accessible toilet is inaccessible because the flush control is on the closed side. TR4 24 months
3.4.k The toilet paper dispenser in the designated accessible stall is inaccessible because it is mounted more than 9 inches from the front of the toilet. TR6 12 months
3.4.l The side grab bar at the designated accessible toilet is inaccessible because it is mounted with the far end 44 inches from the rear wall. TR17 12 months
3.4.m The rear grab bar at the designated accessible toilet is inaccessible because it is 18 inches long and it is mounted 9 1/2 inches from the side wall. TR14 12 months
3.4.n The designated accessible toilet is inaccessible because the rear grab bar is obstructed by the toilet tank. TR15 24 months
3.4.o There is no accessible shower provided. B2 12 months
3.5 Drinking fountain near toilet rooms: The drinking fountain is inaccessible because the spout is 41 1/2 inches high. DF3 24 months
4. Pre-Trial Detention Facility, 501 E. Adams Street
4.1 General: The counters and several other objects at the control stations throughout the facility protrude into the walkways and are not detectable to blind persons using a cane. AR7 24 months
4.2 Ramp to entrance: The ramp is inaccessible because the top landing has a cross-slope of up to 4.5%, there are handrails on only one side of the ramp, the handrail lacks extensions, and the diameter of the handrail is 2 3/4 inches. R1 36 months
4.3 Entrance: The interior vestibule entrance door is inaccessible because it requires 13 pounds of force to open. D3 12 months
4.4 Telephones at front entrance: The telephones are inaccessible because they are 55 1/2 inches high to the highest operable part. TT1 24 months
4.5 Women’s toilet room with stalls at front entrance:    
4.5.a The toilet room sign is mounted on the door. TR11 12 months
4.5.b The entrance door is inaccessible because it requires 12 pounds of force to open. D3 12 months
4.5.c Although an audible alarm is provided in this facility, there is no visual alarm appliance in the toilet room. AL1 36 months
4.5.d No accessible mirror has been provided. TR5 12 months
4.5.e The soap dispenser is inaccessible because it is mounted 56 inches high above the lavatories. CT3 12 months
4.5.f The designated accessible stall is incorrectly configured as an ambulatory stall, and there is no standard accessible stall provided. TR2 36 months
4.6 Men’s toilet room with stalls at the front entrance:    
4.6.a The toilet room sign is mounted on the door. TR11 12 months
4.6.b The entrance door is inaccessible because it requires more than 5 pounds of force to open. D3 12 months
4.6.c Although an audible alarm is provided in this facility, there is no visual alarm appliance in the toilet room. AL1 36 months
4.6.d No accessible mirror has been provided. TR5 12 months
4.6.e The soap dispenser is inaccessible because it is mounted 56 inches high above the lavatories. CT3 12 months
4.6.f The designated accessible stall is incorrectly configured as an ambulatory stall, and there is no standard accessible stall provided. TR2 36 months
4.7 Drinking fountain at front entrance: The drinking fountain is inaccessible because it has a spout that is 43 inches high. DF3 24 months
4.8 First floor visitation area: The door is inaccessible because knob hardware is used. D2 12 months
4.9 Staff toilet room by intake area (used by prisoners with disabilities):    
4.9.a The toilet room sign is mounted on the door. TR11 12 months
4.9.b Although an audible alarm is provided in this facility, there is no visual alarm appliance in the toilet room. AL1 36 months
4.9.c No accessible mirror has been provided. TR5 12 months
4.9.d The toilet is inaccessible because the flush control is on the closed side. TR4 24 months
4.9.e The toilet is inaccessible because the side grab bar is obstructed by the toilet seat cover dispenser. TR15 12 months
4.10 Cells: Accessible housing is not dispersed among the available security levels and housing options within the facility, including isolation cells, etc., and designated accessible cells contain a number of inaccessible features and are not accessible to people with disabilities. PJ1 36 months
4.11 M-2 Clinic staff single user toilet room (used by prisoners with disabilities):    
4.11.a The toilet is inaccessible because there are no grab bars provided. TR18 12 months
4.11.b No accessible mirror has been provided. TR5 12 months
4.11.c The paper towel dispenser is inaccessible because it is mounted with the controls 62 inches high. CT4 12 months
4.11.d The toilet is inaccessible because the top of the seat is 14 1/2 inches high. TR9 36 months
4.11.e The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact. LS2 12 months
4.11.f The lavatory is inaccessible because it has twist-type hardware. LS4 24 months
4.12 Paths of travel: There are several objects located at control stations throughout the facility that protrude into the walkway and are not detectable to blind persons using a cane. AR7 24 months
4.13 Gym - metal ramp at doorway:    
4.13.a The door to the gym is inaccessible because there is a slope of 10% within the door’s required maneuvering clearance due to the metal ramp. D7 36 months
4.13.b The pull side of the door to the gym, which is accessed through a front approach, is inaccessible because it has less than 18 inches of clear space on the latch side. D5 12 months
4.13.c The ramp is inaccessible because it does not have edge protection at the drop off sides. R3 36 months
5. Forsyth Pocket Park / Jesse B. Smith Park, 123 E. Forsyth Street
5.1 Route from street parking:    
5.1.a The curb ramp at the street corner is inaccessible because it has a slope of 10.9% and one flared side has a slope of 16.3%. AR4 36 months
5.1.b The route throughout the park is inaccessible because uneven pavers cause changes in level as high as 1 inch. AR1 36 months
5.2 Drinking fountain: The drinking fountain is inaccessible because the controls require 10 pounds of force to operate. DF2 24 months
6. Florida Theater, 128 E. Forsyth Street
6.1 Exterior route: The curb ramp at the street corner is inaccessible because it has a slope of 9.7% and one flared side has a slope of 28.6%. AR4 36 months
6.2 Main Entrance:    
6.2.a The double doors are inaccessible because each leaf is 28 1/2 inches wide. D13 12 months
6.2.b The doors are inaccessible because the thresholds are between 3/4 inch and 1 inch high and are only partially beveled. D12 24 months
6.3 Box office:    
6.3.a The box office entry door is inaccessible because there is a slope of 9.6% within the door’s required maneuvering clearance. D7 36 months
6.3.b The pull side of the door, which is accessed through a front approach, is inaccessible because it has less than 18 inches of clear space on the latch side. D5 24 months
6.3.c The counter is inaccessible because it is 41 inches high. C1 24 months
6.3.d The door between the box office and theater is inaccessible because knob hardware is used. D2 12 months
6.3.e The door between the box office and theater is inaccessible because the threshold is 3/4 inch high and only partially beveled. D12 24 months
6.4 Designated accessible toilet room with stall in lobby:    
6.4.a The door leading to the toilet room and accessible seating is inaccessible because the threshold is 3/4 inch high and only partially beveled. D12 12 months
6.4.b The door leading to the toilet room and accessible seating is inaccessible because it has knob hardware. D2 12 months
6.4.c The toilet room sign is mounted on the door and has no raised characters. TR11 12 months
6.4.d The second door is inaccessible because it requires 10 pounds of force to open and the door must be lifted slightly. D3 12 months
6.4.e The ashtray protrudes into the walkway and is not detectable to blind persons using a cane. AR7 24 months
6.4.f The stall door is inaccessible because it has an opening width of 30 inches. D14 12 months
6.4.g The side grab bar at the toilet is inaccessible because it is mounted with the far end 48 inches from the rear wall. TR17 12 months
6.5 Lobby refreshment counter: The counter is inaccessible because it is 41 inches high. C1 24 months
6.6 Ramp to accessible theater seating: The ramp is inaccessible because it has a slope of up to 10% near the bottom, there is a handrail on only one side, and the handrail’s ends are not rounded or returned. R4 months
6.7 Drinking fountain on route to accessible seating:    
6.7.a The drinking fountain is inaccessible because the flow of water is 1 inch high. DF5 12 months
6.7.b The wall-mounted drinking fountain is inaccessible because it provides only 24 1/2 inches of clear knee height. DF4 24 months
6.8 Theater:    
6.8.a The entry doors are inaccessible because knob hardware is used. D2 12 months
6.8.b There is no accessible route directly connecting the wheelchair seating areas and the performing areas. AA1 12 months
6.8.c The ramp leading from the street to the stage is inaccessible because it has a slope of 12.3% and it has no handrails. R4 36 months
6.9 Orchestra lobby:    
6.9.a The telephones contain no accessible features and are located in booths too small to accommodate a wheelchair. TT1 24 months
6.9.b The drinking fountains contain a number of inaccessible elements and are inaccessible to people with disabilities. DF1 24 months
6.10 Dressing / green room: The door is inaccessible because it has an opening width of 28 inches. D14 24 months
6.11 Single user toilet room near dressing room:    
6.11.a The toilet room sign is mounted on the door and has no raised characters. TR11 12 months
6.11.b The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact. LS2 12 months
6.11.c The toilet is inaccessible because there is no side grab bar. TR16 12 months
6.11.d The rear grab bar at the designated accessible toilet is inaccessible because it is 18 inches long and it is mounted 32 inches high. TR14 12 months
7. Police Memorial Building, 501 E. Bay Street
7.1 Parking: The parking reserved for persons with disabilities is inaccessible because the designated accessible parking spaces and access aisles have slopes ranging from 3.4% to 6.1%. P4 36 months
7.2 Toilet rooms in front lobby: The toilet rooms contain a number of inaccessible elements and are not accessible to people with disabilities. TR1 36 months
8. Jacksonville Central Health Plaza, 515 W. 6th Street
8.1 Parking lot:    
8.1.a The parking lot, with a total of 221 parking spaces, is inaccessible because it has only 6 spaces designated as accessible. This lot requires 2 van accessible spaces and 5 standard accessible spaces. In addition, the designated van-accessible parking space has an access aisle 72 inches wide. P1 36 months
8.1.b The curb ramp is inaccessible because it has a slope of 9.6%. AR1 36 months
8.2 Route from north parking lot to main entrance: The route is inaccessible because it has a slope of 7.7% with no ramp features. AR1 36 months
8.3 South side parking:    
8.3.a The access aisle is inaccessible because is has a slope of 3.2%. P4 36 months
8.3.b The curb ramp is inaccessible because it has a slope of 9.9%. AR4 36 months
8.3.c The built-up curb ramp impermissibly extends into the required parking space’s access aisle. AR4 36 months
8.4 Exterior entrances: The building does not have directional signage posted at inaccessible entrances and does not have the International Symbol of Accessibility posted at accessible entrances. D10 12 months
8.5 Birth and Death Certificates, Room 106: The door is inaccessible because it requires 17 pounds of force to open. D3 12 months
8.6 Mental Health Services: The door is inaccessible because it requires 14 pounds of force to open. D3 12 months
8.7 Drinking fountain by women’s toilet room:    
8.7.a The drinking fountain is inaccessible because the spout is 44 inches high. DF3 24 months
8.7.b The drinking fountain is inaccessible because the flow of water is less than 4 inches high. DF5 12 months
8.7.c The drinking fountain is inaccessible because the controls require 15 pounds of force to operate. DF2 24 months
8.7.d The wall-mounted drinking fountain is inaccessible because it provides insufficient clear knee height. DF4 24 months
8.8 Drinking fountain by men’s toilet room:    
8.8.a The drinking fountain is inaccessible because the spout is 44 inches high. DF3 24 months
8.8.b The drinking fountain is inaccessible because the flow of water is less than 4 inches high. DF5 12 months
8.8.c The drinking fountain is inaccessible because the controls require 12 pounds of force to operate. DF2 24 months
8.8.d The wall-mounted drinking fountain is inaccessible because it provides insufficient clear knee height. DF4 24 months
8.9 Women’s toilet room on south side:    
8.9.a The toilet room sign is mounted 55 inches high. TR11 12 months
8.9.b The door is inaccessible because it requires 15 pounds of force to open. D3 12 months
8.9.c The pull side of the door, which is accessed through a front approach, is inaccessible because it has approximately 2 inches of clear space on the latch side. D5 24 months
8.9.d Although an audible alarm is provided in this facility, there is no visual alarm appliance in the toilet room. AL1 36 months
8.9.e No accessible mirror has been provided. TR5 12 months
8.9.f The seat cover dispenser is inaccessible because it is mounted with the controls 61 1/2 inches high. CT4 12 months
8.9.g The soap dispenser is inaccessible because it is mounted with the controls 54 inches high above the lavatories. CT3 12 months
8.9.h The paper towel dispenser is inaccessible because it is mounted with the controls 61 inches high. CT4 12 months
8.9.i The lavatory is inaccessible because it has twist-type hardware. LS4 24 months
8.9.j The designated accessible stall is incorrectly configured as an ambulatory stall, and there is no standard accessible stall provided. TR2 36 months
8.9.k The paper towel dispenser protrudes into the walkway and is not detectable to blind persons using a cane. AR7 24 months
8.10 Men’s toilet room on south side:    
8.10.a The toilet room sign does not have raised characters. TR11 12 months
8.10.b The door is inaccessible because it requires 17 pounds of force to open. D3 12 months
8.10.c The pull side of the door, which is accessed through a front approach, is inaccessible because it has inadequate clear space on the latch side. D5 24 months
8.10.d No accessible mirror has been provided. TR5 12 months
8.10.e The soap dispenser is inaccessible because it is mounted with the controls 50 inches high above the lavatories. CT3 12 months
8.10.f The paper towel dispenser is inaccessible because it is mounted with the controls 61 inches high. CT4 12 months
8.10.g The designated accessible stall is incorrectly configured as an ambulatory stall, and there is no standard accessible stall provided. TR2 36 months
8.10.h The paper towel dispenser protrudes into the walkway and is not detectable to blind persons using a cane. AR7 24 months
8.11 Smith Auditorium:    
8.11.a The auditorium is inaccessible to people with hearing disabilities because there is no assistive listening system provided. AA4 12 months
8.11.b The interior ramp is inaccessible because it has a slope of up to 9.2%. R4 12 months
8.11.c The accessible exterior entrance door is kept locked, and persons with disabilities must go to the main entrance to get someone to unlock the door. D8 12 months
8.11.d The exterior ramp to the auditorium is inaccessible because it has a slope of up to 10.1%. R4 12 months
8.11.e The ramp is inaccessible because no handrails are provided. R3 12 months
8.12 Health Center Clinic check-in counter:    
8.12.a The counter is inaccessible because it is 45 1/2 inches high. C1 24 months
8.12.b The counter protrudes into the walkway and is not detectable to blind persons using a cane. AR7 24 months
8.13 Health Center Clinic examination rooms: The examination tables are inaccessible. EB1 36 months
8.14 Single-user toilet room #39 in Women’s Health area:    
8.14.a The toilet is inaccessible because the flush control is on the closed side. TR4 24 months
8.14.b The toilet paper dispenser is inaccessible because it is mounted more than 9 inches from the front of the toilet. TR6 12 months
8.14.c The toilet is inaccessible because the side grab bar is mounted with the far end 50 inches from the rear wall. TR17 12 months
8.15 Single-user toilet room #38 in Women’s Health area:    
8.15.a The toilet paper dispenser is inaccessible because it is mounted more than 9 inches from the front of the toilet. TR6 12 months
8.15.b The toilet is inaccessible because the farther end of the side grab bar is mounted 50 inches from the rear wall. TR17 12 months
8.16 Men’s toilet room with stalls near Dental Clinic:    
8.16.a The paper towel dispenser protrudes into the walkway and is not detectable to blind persons using a cane. AR7 24 months
8.16.b The designated accessible stall is incorrectly configured as an ambulatory stall, and there is no standard accessible stall provided. TR2 36 months
8.17 Women’s toilet room near the dental clinic:    
8.17.a The door is inaccessible because it requires 15 pounds of force to open. D3 12 months
8.17.b The designated accessible stall is incorrectly configured as an ambulatory stall, and there is no standard accessible stall provided. TR2 12 months
8.17.c The paper towel dispenser protrudes into the walkway and is not detectable to blind persons using a cane. AR7 24 months
8.17.d The baby changing table is inaccessible because it is mounted with the controls 57 inches high. CT4 12 months
9. Office of the Sheriff, Community Corrections Division, 451 Catherine Street
9.1 Ramp from parking to entrance: The ramp is inaccessible because it has a slope of up to 9.2%, handrails are not provided on both sides of the ramp, and handrail extensions are not provided. R4 36 months
9.2 Drinking fountain in front lobby: Although a designated accessible drinking fountain is provided, there is no drinking fountain provided for people who have difficulty bending or stooping. DF3 12 months
9.3 Women’s toilet room in front lobby:    
9.3.a The toilet room lacks accessible signage. TR11 12 months
9.3.b The door is inaccessible because it requires 10 pounds of force to open. D3 12 months
9.3.c The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact. LS2 12 months
9.3.d The lavatory is inaccessible because it has twist-type hardware. LS4 24 months
9.3.e The designated accessible stall is incorrectly configured as an ambulatory stall, and there is no standard accessible stall provided. TR2 36 months
9.4 Men’s toilet room in front lobby:    
9.4.a The toilet room lacks accessible signage. TR11 12 months
9.4.b The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact. LS2 12 months
9.4.c The lavatory is inaccessible because it has twist-type hardware. LS4 24 months
9.4.d The urinal is inaccessible because the rim is 19 1/2 inches high. TR8 36 months
9.4.e The designated accessible stall is incorrectly configured as an ambulatory stall, and there is no standard accessible stall provided. TR2 36 months
9.5 Ramp to CCD - A: The ramp is inaccessible because it has a slope of 29.1%, it lacks edge protection, and the handrails lack extensions and are not continuous on one side. R4 36 months
9.6 Entrance to CCD - A (A101): The entrance is inaccessible because it contains an 8 inch high step. AR1 36 months
9.7 Entrance to CCD - B: The entrance is inaccessible because it contains a set of steps. AR1 36 months
9.8 CCD - A and B Dorms:    
9.8.a There is no accessible housing cell provided. PJ1 24 months
9.8.b The toilet rooms contain a number of inaccessible elements and are not accessible to people with disabilities. TR1 36 months
9.8.c There are no accessible showers provided. B2 24 months
9.8.d There is no accessible drinking fountain provided. DF1 24 months
10. Mary Singleton Community Center, 150 E 1st Street
10.1 Curb ramp at bus drop-off: The curb ramp is inaccessible because it has a slope of 18.9%, and the flared sides have slopes of 26.8% and 30.2%. AR4 36 months
10.2 Drinking fountain near auditorium:    
10.2.a The drinking fountain is inaccessible because it has a spout that is 39 inches high. DF3 24 months
10.2.b The drinking fountain protrudes into the walkway and is not detectable to blind persons using a cane. AR7 24 months
10.3 Women’s toilet room across from the auditorium:    
10.3.a The toilet room sign is mounted on the door. TR11 12 months
10.3.b The door is inaccessible because it requires 16 pounds of force to open. D3 12 months
10.3.c No accessible mirror has been provided. TR5 12 months
10.3.d The lavatory is inaccessible because it has twist-type hardware. LS4 24 months
10.3.e There is no accessible toilet stall provided. TR2 36 months
10.3.f No accessible coat hook has been provided. TR3 12 months
10.4 Men’s toilet room across from auditorium:    
10.4.a The toilet room sign is mounted on the door. TR11 12 months
10.4.b The toilet room could not be accessed during the Department’s survey. TR1 36 months
10.5 Center front hall: The wooden box attached to a beam protrudes into the walkway and is not detectable to blind persons using a cane. AR7 24 months
10.6 Drinking fountain by game room:    
10.6.a The drinking fountain is inaccessible because it has a spout that is 38 1/2 inches high. DF3 24 months
10.6.b The drinking fountain protrudes into the walkway and is not detectable to blind persons using a cane. AR7 24 months
10.7 Women’s toilet room by TV lounge:    
10.7.a The toilet room sign had fallen down. TR11, M1 12 months
10.7.b The door is inaccessible because it requires 15 pounds of force to open. D3 12 months
10.7.c The paper towel dispenser protrudes into the walkway and is not detectable to blind persons using a cane. AR7 24 months
10.7.d No accessible mirror has been provided. TR5 12 months
10.7.e The lavatory is inaccessible because it has twist-type hardware. LS4 24 months
10.7.f The designated accessible stall is incorrectly configured as an ambulatory stall, and there is no standard accessible stall provided. TR2 36 months
10.8 Men’s toilet room by TV lounge:    
10.8.a The toilet room sign is mounted on the door. TR11 12 months
10.8.b The door is inaccessible because it requires 15 pounds of force to open. D3 12 months
10.8.c The paper towel dispenser protrudes into the walkway and is not detectable to blind persons using a cane. AR7 24 months
10.8.d No accessible mirror has been provided. TR5 12 months
10.8.e The lavatory is inaccessible because it has twist-type hardware. LS4 24 months
10.8.f The urinal is inaccessible because the rim is 19 inches high. TR8 36 months
10.8.g The designated accessible stall is incorrectly configured as an ambulatory stall, and there is no standard accessible stall provided. TR2 36 months
11. Hanna Park, 500 Wonderwood Drive
11.1 Drinking fountain near main entrance parking lot: The fountain is inaccessible because the spout is 37 1/2 inches high, the control requires 8 pounds of force to operate, the unit does not allow a front approach, and there is no access for people who have difficulty bending or stooping. DF1 24 months
11.2 Public telephone by main entrance: The route to the public telephone is inaccessible because the grass surface is not firm, stable, or slip-resistant, and there is a 2 to 3 inch high step from the parking lot. AR1 36 months
11.3 Main office building: Although a designated accessible drinking fountain is provided, there is no drinking fountain provided for people who have difficulty bending or stooping. DF3 12 months
11.4 Women’s single-user toilet room in main office building:    
11.4.a The door is inaccessible because it requires 11 pounds of force to open. D3 12 months
11.4.b The door is inaccessible because it is obstructed by the carpet and cannot be opened 90 degrees. D14 12 months
11.4.c The lavatory is inaccessible because it has twist-type hardware. LS4 24 months
11.4.d The toilet is inaccessible because its centerline is 20 inches from the side wall. TR7 36 months
11.4.e The toilet paper dispenser in the designated accessible stall is inaccessible because it is mounted more than 9 inches from the front of the toilet. TR6 12 months
11.5 Men’s single-user toilet room in main office building:    
11.5.a The door is inaccessible because it is obstructed by the carpet and cannot be opened 90 degrees. D14 12 months
11.5.b The lavatory is inaccessible because it has twist-type hardware. LS4 24 months
11.5.c The toilet paper dispenser in the designated accessible stall is inaccessible because it is mounted more than 9 inches from the front of the toilet. TR6 12 months
11.6 Ramp from parking lot #11 to beach: The ramp is inaccessible because it does not have a level landing at the bottom of the ramp and the handrails lack extensions. R5 24 months
11.7 Ramp from parking lot #8 to beach: The ramp is inaccessible because the handrails are not continuous, and they lack extensions. R2 24 months
11.8 Parking lot #8, Shelter #1: The picnic tables are inaccessible because none provide the required knee space. DW1 12 months
11.9 Parking lot #8, Shelter #2:    
11.9.a The route to the shelter and to the bleachers is inaccessible because the sand is not firm, stable, and slip-resistant. AR1 36 months
11.9.b The picnic tables are inaccessible because none provide the required knee space. DW1 24 months
11.10 Parking lot #8, Shelter #3: The picnic tables are inaccessible because none provide the required knee space. DW1 24 months
11.11 Parking lot #8 toilet rooms:    
11.11.a The drinking fountain is inaccessible because it has a spout that is 37 1/2 inches high. DF3 24 months
11.11.b The toilet room signs are mounted above the doors and have no raised or Braille characters. TR11 12 months
11.11.c No accessible mirror has been provided in either toilet room. TR5 12 months
11.11.d The air dryers protrude into the walkway and are not detectable to blind persons using a cane. AR7 12 months
11.11.e The lavatory in the men’s toilet room is inaccessible because it has twist-type hardware. LS4 24 months
11.11.f The urinal in the men’s toilet room is inaccessible because the rim is 20 inches high and the flush control is 54 inches high. TR8 36 months
11.11.g The designated accessible stalls are incorrectly configured as ambulatory stalls, and there is no standard accessible stall provided in either room. TR2 36 months
11.12 Parking lot #7: The parking lot is inaccessible because one space reserved for persons with disabilities has a slope of 6.1% and the access aisle has a slope of 3.4%. P4 36 months
11.13 Parking lot #5: The parking lot is inaccessible because there is no designated accessible parking. P1 36 months
11.14 Parking lot #5, Shelters #7, #6, #5:    
11.14.a There is no accessible route to the shelters, or to the volleyball court at Shelter #6, because the grass and sand are not firm, stable, and slip resistant. AR1 36 months
11.14.b The picnic tables are inaccessible because none provide the required knee space. DW1 24 months
11.15 Hanna Park lake and playground:    
11.15.a The parking lot is inaccessible because there is no designated accessible parking. P1 36 months
11.15.b There is no accessible route to the picnic tables or BBQ pit because the grass and sand are not firm, stable, and slip resistant. AR1 36 months
11.15.c The picnic tables are inaccessible because none provide the required knee space. DW1 24 months
11.16 Water Park: The picnic tables are inaccessible because none provide the required knee space. DW1 24 months
11.17 Boat rentals: There is no accessible route to the boat rentals because the grass and sand are not firm, stable, and slip resistant. AR1 36 months
11.18 Parking lot #1:    
11.18.a The parking lot, with a total of 117 parking spaces, is inaccessible because it only has 3 spaces designated as accessible. This lot requires 1 van accessible space and 4 standard accessible spaces. P1 36 months
11.18.b The parking reserved for persons with disabilities is inaccessible because the signs are mounted too low. P3 12 months
11.19 Ramp from parking lot #1 to beach: The ramp is inaccessible because it has a slope of up to 12.9% leading up from the parking lot and a slope of up to 17.3% leading down to the beach, it lacks edge protection, and it does not have compliant handrails. R1 36 months
11.20 Parking lot #2: The parking lot, with a total of 76 parking spaces, is inaccessible because it has no spaces designated as accessible. This lot requires 1 van accessible space and 3 standard accessible spaces. P1 36 months
11.21 Parking lot #3: The parking lot, with a total of 69 parking spaces, is inaccessible because it only has 1 space designated as accessible. This lot requires 1 van accessible space and 2 standard accessible spaces. P1 36 months
11.22 Parking lot #4: The parking lot, with a total of 62 parking spaces, is inaccessible because it only has 2 spaces designated as accessible. This lot requires 1 van accessible space and 2 standard accessible spaces. P1 36 months
11.23 Ramp near parking lot #5 to beach: The ramp is inaccessible because it has slopes in excess of 8.33%, it lacks edge protection, and it lacks compliant handrails. R1 36 months
11.24 Shelter #4:    
11.24.a There is no accessible route to the shelter because the grass and sand are not firm, stable, and slip resistant. AR1 36 months
11.24.b The picnic tables are inaccessible because none provide the required knee space. DW1 24 months
11.25 Shelters #12, 13, 14, 35:    
11.25.a There is no accessible route to these shelters because the grass and sand are not firm, stable, and slip resistant. AR1 36 months
11.25.b The picnic tables are inaccessible because none provide the required knee space. DW1 24 months
11.26 Men’s toilet room with stalls in building #27 near lake:    
11.26.a The toilet room sign is mounted above the door and has no raised or Braille characters. TR11 12 months
11.26.b No accessible mirror has been provided. TR5 12 months
11.26.c The air dryers protrude into the walkway and are not detectable to blind persons using a cane. AR7 12 months
11.26.d The lavatory is inaccessible because the top of the rim or counter is 35 1/2 inches high. LS3 36 months
11.26.e The urinal is inaccessible because the rim is 20 inches high and the flush control is 48 inches high. TR8 36 months
11.26.f The designated accessible stall is incorrectly configured as an ambulatory stall, and there is no standard accessible stall provided. TR2 36 months
11.27 Women’s, Toilet room with stalls in building #27 near lake:    
11.27.a The toilet room sign is mounted above the door and has no raised or Braille characters. TR11 12 months
11.27.b No accessible mirror has been provided. TR5 12 months
11.27.c The air dryer protrudes into the walkway and is not detectable to blind persons using a cane. AR7 12 months
11.27.d The designated accessible stall is incorrectly configured as an ambulatory stall, and there is no standard accessible stall provided. TR2 36 months
11.28 Exterior drinking fountain at building #27:    
11.28.a The drinking fountain is inaccessible because it has a spout that is 39 inches high. DF3 24 months
11.28.b The drinking fountain is inaccessible because the controls require 12 pounds of force to operate. DF2 24 months
11.28.c The drinking fountain is inaccessible because the flow of water is 2 inches high. DF5 12 months
11.28.d The drinking fountain protrudes into the walkway and is not detectable to blind persons using a cane. AR7 24 months
11.28.e The route to from drinking fountain is inaccessible because it has a cross slope of 4.2%. AR1 36 months
11.29 “Mutt Mitt” dispenser at building #27:    
11.29.a The “Mutt Mitt” dispenser protrudes into the walkway and is not detectable to blind persons using a cane. AR7 12 months
11.29.b The “Mutt Mitt” dispenser is inaccessible because it is mounted with the controls 64 1/2 inches high. CT4 12 months
11.30 Ramp to building #27: The ramp is inaccessible because the handrails are mounted 32 inches above the ramp surface and lack extensions. R1 24 months
11.31 Picnic Pavilion #8:    
11.31.a There is no accessible route to the shelter because the grass and sand are not firm, stable, and slip resistant. AR1 36 months
11.31.b The picnic tables are inaccessible because none provide the required knee space. DW1 24 months
11.32 Dolphin Plaza:    
11.32.a The parking space and access aisle reserved for persons with disabilities are inaccessible because they have slopes of 6.5% and cross slopes between 2.8% and 3.9%. P4 36 months
11.32.b The route to the picnic areas is inaccessible because each picnic area has several steps leading to it. AR1 36 months
11.33 Dolphin Plaza building #30 women’s toilet room with stalls:    
11.33.a The toilet room sign is mounted above the door and has no raised or Braille characters. TR11 12 months
11.33.b No accessible mirror has been provided. TR5 12 months
11.33.c The air dryer protrudes into the walkway and is not detectable to blind persons using a cane. AR7 12 months
11.33.d The designated accessible stall is incorrectly configured as an ambulatory stall, and there is no standard accessible stall provided. TR2 12 months
11.34 Dolphin Plaza building #30 men’s toilet room with stalls:    
11.34.a The toilet room sign is mounted above the doors and has no raised or Braille characters. TR11 12 months
11.34.b No accessible mirror has been provided. TR5 12 months
11.34.c The air dryer protrudes into the walkway and is not detectable to blind persons using a cane. AR7 12 months
11.34.d The urinal is inaccessible because the rim is 25 inches high and the flush control is 51 inches high. TR8 36 months
11.34.e The designated accessible stall is incorrectly configured as an ambulatory stall, and there is no standard accessible stall provided. TR2 36 months
11.35 Dolphin Plaza building #23 men’s toilet room with stalls:    
11.35.a No accessible mirror has been provided. TR5 12 months
11.35.b The toilet room is inaccessible because there is insufficient turning space provided within the room. TR21 12 months
11.35.c The air dryer and paper towel dispenser protrude into the walkway and are not detectable to blind persons using a cane. AR7 12 months
11.35.d The urinal is inaccessible because the rim is 29 1/2 inches high. TR8 36 months
11.35.e The toilet paper dispenser in the designated accessible stall is inaccessible because it is mounted more than 9 inches from the front of the toilet. TR6 12 months
11.36 Dolphin Plaza building #23 women’s toilet room with stalls:    
11.36.a The door is inaccessible because it requires 8 pounds of force to open. D3 12 months
11.36.b No accessible mirror has been provided. TR5 12 months
11.36.c The air dryer and paper towel dispenser protrude into the walkway and are not detectable to blind persons using a cane. AR7 12 months
11.36.d The toilet paper dispenser in the designated accessible stall is inaccessible because it is mounted more than 9 inches from the front of the toilet. TR6 12 months
11.37 Dolphin Plaza building #23 banquet room: The banquet room is inaccessible because the arched wooden columns provide an overhead hazard that is not detectable to blind persons using a cane. AR6 24 months
11.38 Pelican Plaza:    
11.38.a The upper ramp closer to building #29 is inaccessible because it has a slope of up to 21%, it lacks a handrail on one side, it lacks handrail extensions, and the ramp lacks edge protection. R1 36 months
11.38.b The ramp between buildings #29 and #31, closer to building #31, is inaccessible because it has a slope of up to 12%, it has no handrails, and there is a two inch depression in the concrete pavement at the top of the ramp. R4 36 months
11.39 Pelican Plaza building #29 women’s toilet room with stalls:    
11.39.a The toilet room sign is mounted above the door and has no raised or Braille characters. TR11 12 months
11.39.b No accessible mirror has been provided. TR5 12 months
11.39.c The air dryer protrudes into the walkway and is not detectable to blind persons using a cane. AR7 12 months
11.39.d The designated accessible stall is incorrectly configured as an ambulatory stall, and there is no standard accessible stall provided. TR2 36 months
11.40 Pelican Plaza building #29 men’s toilet room with stalls:    
11.40.a The toilet room sign is mounted above the door and has no raised or Braille characters. TR11 12 months
11.40.b No accessible mirror has been provided. TR5 12 months
11.40.c The air dryer protrudes into the walkway and is not detectable to blind persons using a cane. AR7 12 months
11.40.d The urinal is inaccessible because the rim is 25 inches high and the flush control is 51 inches high. TR8 36 months
11.40.e The designated accessible stall is incorrectly configured as an ambulatory stall, and there is no standard accessible stall provided. TR2 36 months
12. Times Union Center, 300 W. Water Street
12.1 Main entrance: The door is inaccessible because there is a slope of 5.4% within the door’s required maneuvering clearance. D7 36 months
12.2 Drinking Fountains: The drinking fountains throughout the facility protrude into the walkway and are not detectable to blind persons using a cane. AR7 24 months
12.3 Ramp to SMG offices: The ramp is inaccessible because the handrails are mounted 33 inches high on one side and 33 1/2 inches high on the other side. R3 24 months
12.4 Elevator near main lobby: The elevator is inaccessible because the emergency system requires voice communication to operate. E7 24 months
12.5 Women’s single-user toilet room 1245:    
12.5.a The toilet room sign is mounted on the door. TR11 12 months
12.5.b The toilet seat cover dispenser is inaccessible because it is mounted 48 inches high behind the toilet. CT3 12 months
12.5.c The toilet is inaccessible because the rear grab bar is obstructed by the soap dispenser and the seat cover dispenser. TR15 12 months
12.5.d The toilet is inaccessible because the side grab bar is obstructed by the toilet seat cover dispenser. TR15 12 months
12.5.e The toilet is inaccessible because the flush control is on the closed side. TR4 24 months
12.5.f The feminine products dispenser protrudes into the walkway and is not detectable to blind persons using a cane. AR7 24 months
12.6 Men’s single-user toilet room 1248/1250:    
12.6.a The pull side of the exterior door, which is accessed through a front approach, is inaccessible because it has only 5 1/2 inches of clear space on the latch side. D5 24 months
12.6.b The entry doors are inaccessible because they require 7 pounds and 11 pounds of force to open. D3 12 months
12.6.c The toilet seat cover dispenser is inaccessible because it is mounted 47 inches high behind the toilet. CT3 12 months
12.6.d No accessible coat hook has been provided. TR3 12 months
12.6.e The toilet is inaccessible because the side grab bar is obstructed by the toilet seat cover dispenser. TR15 12 months
12.6.f The toilet is inaccessible because its centerline is 21 inches from the side wall. TR7 36 months
12.6.g The toilet is inaccessible because the flush control is on the closed side. TR4 24 months
12.7 Telephone 1198: The telephone and shelf protrude into the walkway and are not detectable to blind persons using a cane. AR7 24 months
12.8 Women’s single-user toilet room 1215:    
12.8.a The toilet seat cover dispenser is inaccessible because it is mounted 48 inches high behind the toilet. CT3 12 months
12.8.b The toilet is inaccessible because the side grab bar is obstructed by the toilet paper dispenser. TR15 12 months
12.8.c The toilet is inaccessible because the rear grab bar is obstructed by the toilet seat cover dispenser. TR15 12 months
12.9 Women’s toilet room with stalls 1220A:    
12.9.a The designated accessible toilet is inaccessible because the side grab bar is obstructed by the toilet paper dispenser. TR15 12 months
12.9.b The designated accessible toilet is inaccessible because the rear grab bar is obstructed by the toilet seat cover dispenser. TR15 12 months
12.9.c The ambulatory toilet stall is inaccessible because the door swings inward, and the toilet seat is 16 1/2 inches high. TR22 24 months
12.10 Women’s toilet room with stalls 3146:    
12.10.a The designated accessible toilet is inaccessible because the flush control is on the closed side. TR4 24 months
12.10.b The designated accessible toilet is inaccessible because the side grab bar is obstructed by the toilet paper dispenser. TR6 12 months
12.10.c The designated accessible toilet is inaccessible because the rear grab bar is obstructed by the toilet seat cover dispenser. TR15 12 months
12.10.d Although there are 9 toilet stalls, there is no ambulatory stall provided. TR22 24 months
12.11 Women’s toilet room with stalls 3150:    
12.11.a The designated accessible toilet is inaccessible because its centerline is 20 inches from the side wall. TR7 24 months
12.11.b The designated accessible toilet is inaccessible because the side grab bar is obstructed by the toilet paper dispenser. TR6 12 months
12.11.c The designated accessible toilet is inaccessible because the rear grab bar is obstructed by the toilet seat cover dispenser. TR15 12 months
12.11.d Although there are 15 toilet stalls, there is no ambulatory stall provided. TR22 24 months
12.12 Men’s toilet room with stalls 1180A:    
12.12.a No accessible mirror has been provided. TR5 12 months
12.12.b No accessible urinal has been provided. TR8 36 months
12.12.c No accessible coat hook has been provided. TR3 12 months
12.12.d The designated accessible toilet is inaccessible because the flush control is on the closed side. TR4 24 months
12.12.e The side grab bar at the designated accessible toilet is inaccessible because it is obstructed by the toilet paper dispenser. TR15 12 months
12.12.f The designated accessible toilet is inaccessible because the side grab bar is obstructed by the toilet paper dispenser TR6 12 months
12.12.g Although there are 6 toilet stalls, there is no ambulatory stall provided. TR22 24 months
12.13 Austin Lobby (1st floor): The counter is inaccessible because it is 42 1/2 inches high. C1 24 months
12.14 Men’s toilet room with stalls 3140:    
12.14.a No accessible mirror has been provided. TR5 12 months
12.14.b No accessible urinal has been provided. TR8 36 months
12.14.c No accessible coat hook has been provided. TR3 12 months
12.14.d The designated accessible toilet is inaccessible because the flush control is on the closed side. TR4 24 months
12.14.e The designated accessible toilet is inaccessible because its centerline is 20 1/2 inches from the side wall. TR7 24 months
12.14.f The designated accessible toilet is inaccessible because the side grab bar is obstructed by the toilet paper dispenser TR6 12 months
12.14.g The designated accessible toilet is inaccessible because the rear grab bar is obstructed by the toilet seat cover dispenser. TR15 12 months
12.14.h The toilet seat cover dispenser is inaccessible because it is mounted 50 inches high with only a forward reach provided. CT4 12 months
12.14.i The designated accessible toilet stall is inaccessible because its privacy latch is missing while other stalls do have privacy latches. EB1 12 months
12.14.j Although there are 7 toilet stalls, there is no ambulatory stall provided. TR22 24 months
12.15 Men’s toilet room with stalls 3147:    
12.15.a No accessible urinal has been provided. TR8 36 months
12.15.b No accessible coat hook has been provided. TR3 12 months
12.15.c The designated accessible toilet is inaccessible because the side grab bar is obstructed by the toilet paper dispenser TR6 12 months
12.15.d The designated accessible toilet is inaccessible because the rear grab bar is obstructed by the toilet seat cover dispenser. TR15 12 months
12.15.e The toilet seat cover dispenser is inaccessible because it is mounted 50 inches high with only a forward reach provided. CT4 12 months
13. Eastside Park / Flossie Brunson Park, 1050 Franklin Street
13.1 Parking: The parking lot is inaccessible because, although there are 3 designated accessible spaces, there are no access aisles and no vertical signage. P1 36 months
13.2 Entrance: The entrance door is inaccessible because knob hardware is used. D2 12 months
13.3 Women’s toilet room with stalls:    
13.3.a The toilet room sign is mounted on the door and has no raised or Braille characters. TR11 12 months
13.3.b The door is inaccessible because it requires more than 5 pounds of force to open. D3 12 months
13.3.c The sanitary napkin and paper towel dispensers protrude into the walkway and are not detectable to blind persons using a cane. AR7 12 months
13.3.d The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact. LS2 12 months
13.3.e No accessible coat hook has been provided. TR3 12 months
13.3.f The designated accessible stall is inaccessible because it is 40 1/2 inches wide. TR23 12 months
13.3.g The rear grab bar at the toilet is inaccessible because it is 30 inches long. TR13 12 months
13.3.h The side grab bar at the toilet is inaccessible because it is 36 inches long. TR16 12 months
13.4 Men’s toilet room with stalls:    
13.4.a The toilet room sign is mounted on the door and has no raised or Braille characters. TR11 12 months
13.4.b The door is inaccessible because it requires more than 5 pounds of force to open. D3 12 months
13.4.c No accessible mirror has been provided. TR5 12 months
13.4.d The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact. LS2 12 months
13.4.e The urinal is inaccessible because the rim is 24 inches high and the flush control is 49 1/2 inches high. TR8 36 months
13.4.f No accessible coat hook has been provided. TR3 12 months
13.4.g The designated accessible stall is inaccessible because it is 40 inches wide. TR23 12 months
13.4.h The rear grab bar at the toilet is inaccessible because it is 30 inches long. TR13 12 months
13.4.i The side grab bar at the toilet is inaccessible because it is 36 inches long. TR16 12 months
13.5 Drinking fountain: The floor-mounted drinking fountain is inaccessible because it has a spout that is 43 inches high. DF3 24 months
13.6 Ramp to water play area: The ramp is inaccessible because there is no level landing at the top or bottom of the ramp, it has a slope of 10.1%, and the handrails lack extensions. R4 36 months
13.7 Playground: There is no accessible route to the play equipment because the wood chips are not firm, stable and slip resistant. AR1 36 months
13.8 Tennis courts: The entrance is inaccessible because, where there is a 180̊ turn around an obstruction less than 48 inches deep, the path is less than 42 inches wide. AR1 12 months
14. Emmett Reed Center, 1093 West 6th Street
14.1 Parking lot: The parking lot, with a total of 95 parking spaces, is inaccessible because it has no van accessible parking space. This lot requires 1 van accessible space and 3 standard accessible spaces. P1 36 months
14.2 Route from pool to main entrance: The route between the pool and main entrance is inaccessible because there are two significant gaps in the concrete where the surface is not firm, stable, and slip-resistant. AR1 36 months
14.3 Ramp by pool: The ramp is inaccessible because it lacks edge protection at the drop off sides. R3 36 months
14.4 Ramps to locker rooms: The ramps are inaccessible because they lack handrails. R3 24 months
14.5 Drinking fountains: Although designated accessible drinking fountains are provided throughout the facility, there are no drinking fountains provided for people who have difficulty bending or stooping. DF3 12 months
14.6 Women’s single user toilet room near main entrance:    
14.6.a The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact. LS2 12 months
14.6.b The toilet is inaccessible because its centerline is 19 1/2 inches from the side wall. TR7 36 months
14.6.c The toilet paper dispenser in the designated accessible stall is inaccessible because it is mounted more than 9 inches from the front of the toilet. TR6 12 months
14.6.d The toilet is inaccessible because the side grab bar is obstructed by the toilet paper dispenser. TR15 12 months
14.7 Men’s single user toilet room near main entrance:    
14.7.a The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact. LS2 12 months
14.7.b The toilet is inaccessible because its centerline is 19 1/2 inches from the side wall. TR7 36 months
14.7.c The toilet paper dispenser in the designated accessible stall is inaccessible because it is mounted more than 9 inches from the front of the toilet. TR6 12 months
14.7.d The toilet is inaccessible because the side grab bar is obstructed by the toilet paper dispenser. TR15 12 months
14.8 Check-in counter outside gym: The counter is inaccessible because it is 41 inches high. C1 24 months
14.9 Men’s locker room:    
14.9.a The toilet room sign is mounted on the door and has no raised or Braille characters. TR11 12 months
14.9.b The door is inaccessible because it requires 22 pounds of force to open. D3 12 months
14.9.c The pull side of the door, which is accessed through a front approach, is inaccessible because it lacks clear floor space on the latch side. D5 24 months
14.9.d The lavatory is inaccessible because the bottom of the apron is 26 inches high. LS3 36 months
14.9.e The lavatory is inaccessible because it has twist-type hardware. LS4 24 months
14.9.f The urinal is inaccessible because the rim is 24 inches high. TR8 36 months
14.9.g No accessible shower is provided. B2 24 months
14.9.h The bench is inaccessible because it is 12 inches wide and 13 inches high. LR2 24 months
14.10 Women’s locker room:    
14.10.a The toilet room sign is mounted on the door and has no raised or Braille characters. TR11 12 months
14.10.b The door is inaccessible because it requires 22 pounds of force to open. D3 12 months
14.10.c The pull side of the door, which is accessed through a front approach, is inaccessible because it lacks clear floor space on the latch side. D5 12 months
14.10.d The lavatory is inaccessible because it has twist-type hardware. LS4 24 months
14.10.e No accessible shower is provided. B2 24 months
14.10.f The bench is inaccessible because it is 14 inches high, and it is not attached to the wall. LR2 24 months
14.11 1st floor exercise room: The fire extinguisher is a protruding object and is not detectable to blind persons using a cane. AR7 24 months
14.12 Women’s rear lobby toilet room with stalls:    
14.12.a The toilet is inaccessible because its centerline is 20 1/2 inches from the side wall. TR7 24 months
14.12.b No accessible coat hook has been provided. TR3 12 months
14.12.c The designated accessible toilet is inaccessible because the side grab bar is obstructed by the toilet paper dispenser. TR15 12 months
14.13 Men’s rear lobby toilet room with stalls:    
14.13.a The urinal is inaccessible because the rim is 24 inches high. TR8 36 months
14.13.b The toilet is inaccessible because the flush control is on the closed side. TR4 24 months
14.13.c No accessible coat hook has been provided. TR3 12 months
14.13.d The designated accessible toilet is inaccessible because the side grab bar is obstructed by the toilet paper dispenser. TR15 12 months
14.14 Elevator, rear lobby:    
14.14.a The elevator is inaccessible because, after reopening due to an obstruction, the doors stay open less than 20 seconds. E6 24 months
14.14.b The elevator is inaccessible because the emergency controls are not grouped together at the bottom of the panel. E8 24 months
14.14.c The elevator is inaccessible because the car position indicators do not ring or illuminate as the car passes or stops on floors. E5 24 months
14.14.d The elevator is inaccessible because the emergency system requires voice communication to operate. E7 24 months
14.15 2nd floor offices:    
14.15.a The doors are inaccessible because knob hardware is used. D2 12 months
14.15.b The signage provided is inaccessible because it is mounted above the doors and does not have raised and Braille characters. D15 12 months
14.16 Men’s 2nd floor toilet room with stalls:    
14.16.a The lavatory is inaccessible because it has twist-type hardware. LS4 24 months
14.16.b The urinal is inaccessible because the rim is more than 17 inches high. TR8 36 months
14.16.c No accessible coat hook has been provided. TR3 12 months
14.16.d The toilet is inaccessible because the flush control is on the closed side. TR4 24 months
14.16.e The designated accessible toilet is inaccessible because the side grab bar is obstructed by the toilet paper dispenser. TR15 12 months
14.17 Women’s 2nd floor toilet room with stalls: The toilet room contains a number of inaccessible elements and is not accessible to people with disabilities. TR1 24 months
14.18 Telephone: The telephone protrudes into the walkway and is not detectable to blind persons using a cane. AR7 24 months
15. Head Start, 515 Victoria Street
15.1 Entrances: The building does not have directional signage posted at inaccessible entrances and does not have the International Symbol of Accessibility posted at accessible entrances. D10 12 months
15.2 Parking: The parking lot, with a total of 18 parking spaces, is inaccessible because there are no accessible parking spaces. This lot requires 1 van accessible space. P1 36 months
15.3 Rear entrance:    
15.3.a The entrance ramp is inaccessible because it has a slope of up to 13.4% and it has no compliant handrails. R4 36 months
15.3.b The door is inaccessible because there is a 1 1/2 inch high threshold. D12 24 months
15.4 Fire extinguishers: The fire extinguishers by the door and the drinking fountain protrude into the walkway and are not detectable to blind persons using a cane. AR7 24 months
15.5 Interior doors: The doors throughout the facility are inaccessible because knob hardware is used. D2 12 months
15.6 Intake room:    
15.6.a There is no accessible route to the room because furniture narrows the path of travel to less than 32 inches wide. AR1 12 months
15.6.b The door is inaccessible because it has an opening width of 30 inches. D14 24 months
15.7 Single user unisex toilet room:    
15.7.a The toilet room sign is mounted on the door and has no raised or Braille characters. TR11 12 months
15.7.b Although an audible alarm is provided in this facility, there is no visual alarm appliance in the toilet room. AL1 36 months
15.7.c The toilet is inaccessible because its centerline is 25 inches from the side wall. TR7 36 months
15.7.d The toilet is inaccessible because the flush control is on the closed side. TR4 24 months
15.7.e The side grab bar at the toilet is inaccessible because it is 30 inches long. TR16 12 months
15.7.f The toilet is inaccessible because no rear grab bar is provided. TR13 12 months
15.8 Exterior playground: There is no accessible route to the play area because the grass is not firm, stable, and slip resistant. AR1 36 months
16. Julius Guinyard Park (Jefferson Street Park), 1358 N Jefferson Street
16.1 Playground: There is no accessible route to the playground because the grass is not firm, stable, and slip resistant. AR1 36 months
16.2 Picnic area: The route to the picnic area is inaccessible because the grass is not firm, stable, and slip resistant. AR1 36 months
16.3 Baseball field: The route to the baseball field picnic area is inaccessible because the grass is not firm, stable, and slip resistant. AR1 36 months
17. Durkee Field - James Small Stadium, 1701 Myrtle Avenue North / 1200 West 8th Street
17.1 Seating area:    
17.1.a The ramp to the seating area is inaccessible because there is no handrail on one side at the bottom of the ramp, and the ramp has a slope of up to 9.5%. R2 36 months
17.1.b The stadium is inaccessible because no wheelchair seating areas are provided. AA6 36 months
17.2 Unisex single user toilet rooms near ticket counter and museum: Although an audible alarm is provided in this facility, there are no visual alarm appliances in these toilet rooms. AL1 36 months
17.3 Men’s and women’s toilet rooms with stalls near ticket counter: There is no signage directing people with disabilities to the accessible toilet rooms, and the inaccessible toilet rooms have signage indicating that they are accessible. TR16 12 months
17.4 Concession Counters:    
17.4.a The counters are all inaccessible because they are between 40 inches and 43 inches high. C1 12 months
17.4.b The counters protrude into the walkway and are not detectable to blind persons using a cane. AR7 12 months
17.5 Dugouts: There is no accessible route to the dugouts because the dirt is not firm, stable, and slip resistant. AR1 36 months
17.6 Picnic tables: The picnic areas are inaccessible because none of the picnic tables provide accessible knee space. DW1 24 months
17.7 Playground: There playground is inaccessible because there is a step to get onto the playground surface and the sand surface is not firm, stable, and slip resistant. AR1 36 months
18. Clanzel T. Brown Community Center, 4575 Moncrief Road
18.1 Parking:    
18.1.a The parking lot, with a total of 163 parking spaces, is inaccessible because there are only 5 accessible spaces provided and none are designated van-accessible. This lot requires 1 van accessible space and 5 standard accessible spaces. P1 36 months
18.1.b The designated accessible parking spaces by the tennis couts are inaccessible because the access aisle is only 34 inches wide. P2 36 months
18.2 Interior signage: The signage provided throughout the facility is inaccessible because it does not have raised and Braille characters. D15 12 months
18.3 Sign-in counter: The counter is inaccessible because it is 41 1/2 inches high. C1 24 months
18.4 Drinking fountain near toilet rooms: The drinking fountain is inaccessible because it has a spout that is 39 inches high. DF3 24 months
18.5 Men’s toilet room with stalls:    
18.5.a The toilet room sign is mounted on the door and has no raised or Braille characters. TR11 12 months
18.5.b The door is inaccessible because it requires 20 pounds of force to open. D3 12 months
18.5.c The entrance is inaccessible because the vestibule is 41 1/2 inches deep from the end of the open door. D4 12 months
18.5.d No accessible mirror has been provided. TR5 12 months
18.5.e The paper towel dispenser by the inaccessible lavatory protrudes into the walkway and is not detectable to blind persons using a cane. AR7 12 months
18.5.f The urinal is inaccessible because the rim is 25 inches high and the flush control is 51 1/2 inches high. TR8 36 months
18.5.g The designated accessible toilet is inaccessible because the flush control is on the closed side. TR4 24 months
18.5.h No accessible coat hook has been provided. TR3 12 months
18.5.i The side grab bar at the toilet is inaccessible because it is 36 inches long. TR13 12 months
18.5.j The rear grab bar at the toilet is inaccessible because it is 18 inches long and it is mounted 7 1/2 inches from the side wall. TR16 12 months
18.6 Women’s toilet room with stalls:    
18.6.a The toilet room sign is mounted on the door and has no raised or Braille characters. TR11 12 months
18.6.b The entrance is inaccessible because the vestibule is 42 1/2 inches deep from the end of the open door. D4 12 months
18.6.c No accessible mirror has been provided. TR5 12 months
18.6.d The soap dispenser is inaccessible because it is mounted with the controls 50 1/2 inches high between the lavatories. CT3 12 months
18.6.e The lavatory is inaccessible because the top of the rim or counter is 35 inches high. LS3 36 months
18.6.f The lavatory is inaccessible because it has twist-type hardware. LS4 12 months
18.6.g No accessible coat hook has been provided. TR3 12 months
18.6.h The designated accessible toilet is inaccessible because the side grab bar is obstructed by the toilet paper dispenser. TR15 12 months
18.6.i The side grab bar at the toilet is inaccessible because it is 36 inches long. TR13 12 months
18.6.j The rear grab bar at the toilet is inaccessible because it is 18 inches long and it is mounted 8 1/2 inches from the side wall. TR16 12 months
18.7 Patio: The picnic tables are inaccessible because none provide the required knee space. DW1 24 months
19. Clanzel T. Brown Pool, 4515 Moncrief Road
19.1 Route from parking lot to pool: The route is inaccessible because adequate passing space is not provided along its length, the pavement is cracked and has gaps of greater than 1/2 inch, and it has slopes and cross slopes of up to 12.4%. AR1 36 months
19.2 Drinking fountain: The floor-mounted drinking fountain is inaccessible because its spout is 38 inches high, and there is no knee space provided. DF1 24 months
19.3 Women’s locker room:    
19.3.a The locker room sign is high on the wall and has no raised or Braille characters. TR11 12 months
19.3.b The lavatory is inaccessible because it has twist-type hardware. LS4 12 months
19.3.c The designated accessible stall is incorrectly configured as an ambulatory stall, and there is no standard accessible stall provided. TR2 36 months
19.3.d There is no accessible shower provided. B2 24 months
19.3.e There is no bench provided. LR2 24 months
19.4 Men’s locker room:    
19.4.a The locker room sign is too high on the wall and has no raised or Braille characters. TR11 12 months
19.4.b The lavatory is inaccessible because it has twist-type hardware. LS4 12 months
19.4.c The urinal is inaccessible because the rim is 21 1/2 inches high and the flush control is 49 inches high. TR8 36 months
19.4.d The designated accessible stall is incorrectly configured as an ambulatory stall, and there is no standard accessible stall provided. TR2 36 months
19.4.e There is no accessible shower provided. B2 24 months
19.4.f There is no bench provided. LR2 24 months
20. Clanzel T. Brown Sports Complex, 4575 Moncrief Road
20.1 Routes: The routes to the basketball court, baseball fields, picnic areas, and benches are inaccessible because the grass is not firm, stable, and slip resistant. AR1 36 months
20.2 Picnic tables: The picnic tables are inaccessible because none provide the required knee space. DW1 24 months
20.3 Women’s locker room at tennis pavilion:    
20.3.a The toilet room sign is mounted on the door and has no raised or Braille characters. TR11 12 months
20.3.b Although an audible alarm is provided in this facility, there is no visual alarm appliance in the toilet room. AL1 36 months
20.3.c The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact. LS2 12 months
20.3.d The designated accessible stall is incorrectly configured as an ambulatory stall, and there is no standard accessible stall provided. TR2 36 months
20.3.e No accessible shower is provided. B2 12 months
20.3.f The bench is inaccessible because it is 13 1/4 inches wide and 19 1/2 inches high. LR2 12 months
20.3.g There is no accessible locker provided. LR3 24 months
20.4 Men’s locker room at tennis pavilion:    
20.4.a The toilet room sign is mounted on the door and has no raised or Braille characters. TR11 12 months
20.4.b Although an audible alarm is provided in this facility, there is no visual alarm appliance in the toilet room. AL1 36 months
20.4.c No accessible mirror has been provided. TR5 12 months
20.4.d The urinal is inaccessible because the rim is 19 1/2 inches high. TR8 36 months
20.4.e The designated accessible stall is incorrectly configured as an ambulatory stall, and there is no standard accessible stall provided. TR2 36 months
20.4.f No accessible shower is provided. B2 12 months
20.4.g The bench is inaccessible because it is 13 1/4 inches wide and 19 1/2 inches high. LR2 24 months
20.4.h There is no accessible locker provided. LR3 12 months
20.5 Drinking fountain at tennis pavilion:    
20.5.a The drinking fountain is inaccessible because it has a spout that is 41 1/2 inches high. DF3 24 months
20.5.b The drinking fountain is inaccessible because the controls require 8 pounds of force to operate. DF2 24 months
21. Supervisor of Elections, 231 East Forsyth Street
21.1 Curb ramp: The curb ramp is inaccessible because it has a slope of 13.5%. AR4 36 months
21.2 Route to entrance: The route from the parking area to the entrance is inaccessible because it has a cross slope of 3.8% in at least one location. AR1 36 months
22. Claude Yates City Hall Annex, 231 East Forsyth Street
22.1 Entrances: The building does not have the International Symbol of Accessibility posted at accessible entrances. D10 12 months
22.2 Interior room signage: The room signage throughout the facility is inaccessible because it is not mounted 48-60 inches high and it lacks raised and Braille characters. D15 12 months
22.3 Counters throughout facility, including rooms 230, 260, 270, 330, 350, 360, and 470: The counters protrude into the walkway and are not detectable to blind persons using a cane. AR7 24 months
22.4 Drinking fountains: Although designated accessible drinking fountains are provided, there is no drinking fountain provided in the facility for people who have difficulty bending or stooping. DF3 12 months
22.5 Elevators 1 & 2: The elevators are inaccessible because the emergency communications require tight grasping and pinching to access. E7 24 months
22.6 Drinking fountain near room 163: The drinking fountain protrudes into the walkway and is not detectable to blind persons using a cane. AR7 24 months
22.7 Men’s toilet room with stalls near room 163:    
22.7.a The toilet room sign is mounted on the door and has no raised or Braille characters. TR11 12 months
22.7.b The door is inaccessible because it requires 11 pounds of force to open. D3 12 months
22.7.c The air dryer protrudes into the walkway and is not detectable to blind persons using a cane. AR7 12 months
22.7.d The toilet seat cover dispenser is inaccessible because it is mounted 64 inches high. CT4 12 months
22.7.e The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact. LS2 12 months
22.7.f The designated accessible stall is incorrectly configured as an ambulatory stall, and there is no standard accessible stall provided. TR2 36 months
22.8 Women’s toilet room with stalls near room 165:    
22.8.a The toilet room sign is mounted on the door and has no raised or Braille characters. TR11 12 months
22.8.b The door is inaccessible because it requires 11 pounds of force to open. D3 12 months
22.8.c The toilet seat cover dispenser is inaccessible because it is mounted 58 inches high. CT3 12 months
22.8.d The air dryer protrudes into the walkway and is not detectable to blind persons using a cane. AR7 12 months
22.8.e The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact. LS2 12 months
22.8.f The designated accessible stall is incorrectly configured as an ambulatory stall, and there is no standard accessible stall provided. TR2 36 months
22.9 Drinking fountain near room 109: The drinking fountain protrudes into the walkway and is not detectable to blind persons using a cane. AR7 12 months
22.10 Men’s toilet room with stalls near room 263:    
22.10.a The toilet room sign is mounted on the door and has no raised or Braille characters. TR11 12 months
22.10.b The door is inaccessible because it requires 9 pounds of force to open. D3 12 months
22.10.c The toilet seat cover dispenser is inaccessible because it is mounted 61 inches high. CT3 12 months
22.10.d The air dryer protrudes into the walkway and is not detectable to blind persons using a cane. AR7 12 months
22.10.e The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact. LS2 12 months
22.10.f The designated accessible stall is incorrectly configured as an ambulatory stall, and there is no standard accessible stall provided. TR2 36 months
22.11 Women’s toilet room with stalls near room 263:    
22.11.a The toilet room sign is mounted on the door and has no raised or Braille characters. TR11 12 months
22.11.b The door is inaccessible because it requires 11 pounds of force to open. D3 12 months
22.11.c The toilet seat cover dispenser is inaccessible because it is mounted 60 inches high. CT3 12 months
22.11.d The air dryer protrudes into the walkway and is not detectable to blind persons using a cane. AR7 12 months
22.11.e The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact. LS2 12 months
22.11.f The designated accessible stall is incorrectly configured as an ambulatory stall, and there is no standard accessible stall provided. TR2 12 months
22.12 Men’s toilet room with stalls 3rd floor:    
22.12.a The toilet room sign is mounted on the door and has no raised or Braille characters. TR11 12 months
22.12.b The door is inaccessible because it requires 10 pounds of force to open. D3 12 months
22.12.c The toilet seat cover dispenser is inaccessible because it is mounted 61 inches high. CT3 12 months
22.12.d The air dryer protrudes into the walkway and is not detectable to blind persons using a cane. AR7 12 months
22.12.e The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact. LS2 12 months
22.12.f The designated accessible stall is incorrectly configured as an ambulatory stall, and there is no standard accessible stall provided. TR2 36 months
22.13 Women’s toilet room with stalls 3rd floor:    
22.13.a The toilet room sign is mounted on the door and has no raised or Braille characters. TR11 12 months
22.13.b The door is inaccessible because it requires 10 pounds of force to open. D3 12 months
22.13.c The air dryer and paper towel dispenser protrude into the walkway and are not detectable to blind persons using a cane. AR7 12 months
22.13.d The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact. LS2 12 months
22.13.e The designated accessible stall is incorrectly configured as an ambulatory stall, and there is no standard accessible stall provided. TR2 36 months
22.14 Room 450: The door is inaccessible because it requires 15 pounds of force to open. D3 12 months
22.15 Room 470: The door is inaccessible because it requires 16 pounds of force to open. D3 12 months
22.16 Drinking fountain near room 463: The drinking fountain is inaccessible because the water flow is 3 inches high. DF5 12 months
23. Bethesda Park, 10790 Key Haven Boulevard
23.1 Community room:    
23.1.a The office counter protrudes into the walkway and is not detectable to blind persons using a cane. AR7 24 months
23.1.b The community room is inaccessible because no assistive listening system is provided. AA4 36 months
23.2 Kitchen: The paper towel dispenser is inaccessible because it is mounted 53 inches high over the sink. CT3 12 months
23.3 Men’s toilet room with stalls near main entrance:    
23.3.a The toilet room sign is mounted on the door and has no raised or Braille characters. TR11 12 months
23.3.b No accessible coat hook has been provided. TR3 12 months
23.4 Women’s toilet room with stalls near main entrance: The toilet room sign is mounted on the door and has no raised or Braille characters. TR11 12 months
23.5 Route to Cabins 3 & 4: The route is inaccessible because there is a 1 1/2 inch high change in level on the sidewalk. AR1 36 months
23.6 Cabin 3 single user toilet room:    
23.6.a The toilet is inaccessible because the flush control is on the closed side. TR4 24 months
23.6.b The toilet paper dispenser in the designated accessible stall is inaccessible because it is mounted more than 9 inches from the front of the toilet. TR6 12 months
23.6.c The toilet is inaccessible because the side grab bar is 36 inches long. TR17 12 months
23.6.d The toilet is inaccessible because there is no rear grab bar provided. TR13 12 months
23.6.e The roll-in shower is inaccessible because there are insufficient grab bars provided. B2 12 months
23.7 Cabin 4 single user toilet room:    
23.7.a The toilet is inaccessible because its centerline is 15 1/2 inches from the side wall. TR7 36 months
23.7.b The toilet is inaccessible because the side grab bar is 36 inches long. TR17 12 months
23.7.c The toilet is inaccessible because there is no rear grab bar provided. TR13 12 months
23.7.d The roll-in shower is inaccessible because there are insufficient grab bars provided. B2 12 months
24. Yates Parking Garage, 200 East Adams Street
24.1 Parking: The garage, with a total of 660 parking spaces, is inaccessible because it only has 1 space designated as van-accessible, one of the Ground level designated accessible spaces and access aisles has a slope of 7.9% and the other is not on the shortest accessible route to an accessible entrance, and many of the other designated accessible spaces have access aisles 47 inches wide and/or obstructed by columns, and the signage on the 6th floor is mounted too low. This lot requires 3 van accessible spaces and 11 standard accessible spaces. P1 36 months
24.2 Elevators:    
24.2.a The elevators are inaccessible because hall lanterns are only provided on the first floor. E10 24 months
24.2.b The elevators are inaccessible because the emergency communications require tight grasping or pinching to access. E7 24 months
25. Wallace Small Senior Center 1083 Line St.
25.1 Parking: The designated accessible parking space is inaccessible because it has no access aisle and there is no van accessible space provided. P1 36 months
25.2 Entrance ramp: The ramp is inaccessible because it has a slope of up to 10.3% and it has a handrail on only one side. R4 36 months
25.3 Drinking fountain near sign in counter:    
25.3.a The drinking fountain is inaccessible because the controls require 10 pounds of force to operate. DF2 24 months
25.3.b The wall-mounted drinking fountain is inaccessible because it provides only 22 1/2 inches of knee space. DF4 24 months
25.3.c Although a designated accessible drinking fountain is provided, there is no drinking fountain provided for people who have difficulty bending or stooping. DF3 24 months
25.4 Kitchen:    
25.4.a The door is inaccessible because knob hardware is used. D2 12 months
25.4.b The sink is inaccessible because there is no knee space provided. LS3 12 months
25.5 Women’s single user toilet room:    
25.5.a The toilet room sign is mounted on the door and has no raised or Braille characters. TR11 12 months
25.5.b Although an audible alarm is provided in this facility, there is no visual alarm appliance in the toilet room. AL1 36 months
25.5.c The toilet is inaccessible because its centerline is 16 inches from the side wall. TR7 12 months
25.5.d The toilet is inaccessible because the flush control is on the closed side. TR4 24 months
25.5.e The rear grab bar at the toilet is inaccessible because it is 24 inches long. TR13 12 months
25.6 Men’s single user toilet room:    
25.6.a The toilet room sign is mounted on the door and has no raised or Braille characters. TR11 12 months
25.6.b Although an audible alarm is provided in this facility, there is no visual alarm appliance in the toilet room. AL1 36 months
25.6.c The urinal is inaccessible because the rim is 20 inches high. TR8 36 months
25.6.d The toilet is inaccessible because its centerline is 16 inches from the side wall. TR7 12 months
25.6.e The rear grab bar at the toilet is inaccessible because it is 24 inches long. TR13 12 months
25.7 Picnic shelter: The picnic tables are inaccessible because none provide the required knee space. DW1 24 months
26. Fire Station #1, 611 North Liberty Street
26.1 Men’s toilet room:    
26.1.a The toilet room sign is mounted on the door. TR11 12 months
26.1.b Although an audible alarm is provided in this facility, there is no visual alarm appliance in the toilet room. AL1 36 months
26.1.c No accessible mirror has been provided. TR5 12 months
26.1.d The paper towel dispenser is inaccessible because it is mounted 51 inches high over the lavatories. CT3 12 months
26.1.e The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact. LS2 12 months
26.1.f The designated accessible stall is incorrectly configured as an ambulatory stall, and there is no standard accessible stall provided. TR2 36 months
26.1.g No accessible shower is provided. B2 12 months
27. Park Admin Offices, 851 North Market Street
27.1 Parking: The designated accessible parking space is inaccessible because it has a slope of 5.9% and the access aisle has a slope of 6.5%. P4 36 months
27.2 Designated accessible entrance:    
27.2.a The route to the entrance is inaccessible because there is a slope of 10.4% leading to the door. AR1 36 months
27.2.b The door is inaccessible because there is a slope of 11.4% within the door’s required maneuvering clearance. D7 36 months
27.2.c The door is inaccessible because there is a 1 inch high threshold. D12 12 months
27.3 Interior doors: Many of the doors throughout the facility are inaccessible because knob hardware is used. D2 12 months
27.4 Visitor’s office: The counter protrudes into the walkway and is not detectable to blind persons using a cane. AR7 12 months
27.5 Elevator: The elevator is inaccessible because the emergency system requires voice communication to operate. E7 24 months
27.6 Men’s toilet room with stalls in basement:    
27.6.a The door is inaccessible because it requires 7 pounds of force to open. D3 12 months
27.6.b The soap dispenser is inaccessible because it is mounted with the controls 56 inches high. CT4 12 months
27.6.c The urinal is inaccessible because the rim is 24 inches high. TR8 12 months
27.6.d No accessible coat hook has been provided. TR3 12 months
27.7 Women’s toilet room with stalls in basement:    
27.7.a The door is inaccessible because it requires 7 pounds of force to open. D3 12 months
27.7.b No accessible coat hook has been provided. TR3 12 months
27.8 2nd Floor drinking fountain: Although a designated accessible drinking fountain is provided, there is no drinking fountain provided for people who have difficulty bending or stooping. DF3 12 months
27.9 Single user toilet rooms on 1st and 2nd floor: These toilet rooms are inaccessible and there is no signage directing people with disabilities to the designated accessible basement toilet rooms. TR16 12 months
28. Adams Street Parking Garage, 231 East Adams Street
28.1 Parking:    
28.1.a The designated accessible spaces and access aisles on level 2 are inaccessible because they have slopes between 3.9% and 5.8%. P4 36 months
28.1.b There are no accessible van parking spaces because the garage has a vertical clearance of 88 inches. P8 36 months
28.1.c One of the designated accessible parking spaces on level 3 is inaccessible because it does not have vertical signage. P3 12 months
28.2 Route to elevator on level 2: The route from the parking area to the elevator is inaccessible because it has a slope of up to 7.2%. AR1 36 months
28.3 Elevator:    
28.3.a The elevator is inaccessible because there is no hoistway signage provided. E12 24 months
28.3.b The elevator is inaccessible because there are no hall lantern signals. E10 24 months
28.3.c The elevator is inaccessible because the time from notification that a car is answering a call until the doors of that car start to close is 4 seconds. E6 24 months
28.3.d The elevator is inaccessible because the emergency system requires voice communication to operate. E7 24 months
29. J.S. Johnson Community Center, 1112 Jackson Street
29.1 Exterior route: The route is inaccessible because there are changes in level 1 inch high at the end of the parking access aisle and at the entrance to the tennis court. AR1 36 months
29.2 Interior doors: The doors throughout the facility are inaccessible because knob hardware is used. D2 12 months
29.3 Kitchen:    
29.3.a The sink is inaccessible because it has twist type knobs and does not provide knee space. LS1 12 months
29.3.b The paper towel dispenser is inaccessible because it is mounted 67 inches high. CT3 12 months
29.4 Social room: The computer table is inaccessible because it is 26 1/4 inches high to the bottom edge. T1 24 months
29.5 Drinking fountain in main hallway:    
29.5.a The drinking fountain is inaccessible because it has a spout that is 42 inches high. DF3 12 months
29.5.b The drinking fountain protrudes into the walkway and is not detectable to blind persons using a cane. AR7 12 months
29.6 Ceramic room: The sink is inaccessible because it has twist type knobs. LS4 24 months
29.7 Inaccessible toilet rooms: There is no signage directing people with disabilities to the accessible toilet rooms. TR16 12 months
29.8 Men’s single user toilet room in pool room:    
29.8.a The toilet room sign does not have the International Symbol of Accessibility. TR11 12 months
29.8.b No accessible mirror has been provided. TR5 12 months
29.8.c The toilet is inaccessible because the seat is 15 3/4 inches high. SU14 36 months
29.8.d The side grab bar at the toilet is inaccessible because it is mounted with the far end 47 inches from the rear wall. TR16 12 months
29.8.e The rear grab bar at the toilet is inaccessible because it is 30 inches long and it is mounted 7 inches from the side wall. TR13 12 months
29.9 Women’s single user toilet room in pool room:    
29.9.a The toilet room sign does not have the International Symbol of Accessibility. TR11 12 months
29.9.b No accessible mirror has been provided. TR5 12 months
29.9.c The toilet is inaccessible because the flush control is on the closed side. TR4 12 months
29.9.d The side grab bar at the toilet is inaccessible because it is mounted with the far end 47 inches from the rear wall. TR16 12 months
29.9.e The rear grab bar at the toilet is inaccessible because it is 30 inches long and it is mounted 7 inches from the side wall. TR13 12 months
29.9.f The rear grab bar at the toilet is inaccessible because it is obstructed by the toilet tank. TR15 12 months
29.9.g The toilet room door swings into the required clear floor space at the lavatory. TR6 12 months
29.10 Drinking fountain in pool room:    
29.10.a The drinking fountain is inaccessible because the flow of water is less than 4 inches high. DF5 12 months
29.10.b The drinking fountain is inaccessible because the controls require 7 pounds of force to operate. DF2 12 months
29.10.c The drinking fountain protrudes into the walkway and is not detectable to blind persons using a cane. AR7 12 months
29.10.d Although a designated accessible drinking fountain is provided, there is no drinking fountain provided for people who have difficulty bending or stooping. DF3 12 months
30. Beaches Senior Center, 281 19th Avenue South
30.1 Front entrance:    
30.1.a The front entrance is inaccessible because there is a slope of 9% near the door. AR1 36 months
30.1.b There is no accessible route to the picnic tables in front of the facility because there is a step up onto the curb. AR1 36 months
30.2 Interior doors: The doors throughout the facility are inaccessible because knob hardware is used. D2 12 months
30.3 Classroom: The defibrillator protrudes into the walkway and is not detectable to blind persons using a cane. AR7 24 months
30.4 Drinking fountain by toilet rooms: Although a designated accessible drinking fountain is provided, there is no drinking fountain provided for people who have difficulty bending or stooping. DF3 12 months
30.5 Women’s toilet room:    
30.5.a The toilet room sign is mounted on the door and has no raised or Braille characters. TR11 12 months
30.5.b Although an audible alarm is provided in this facility, there is no visual alarm appliance in the toilet room. AL1 36 months
30.5.c The lavatory is inaccessible because the top of the rim or counter is 36 inches high. LS3 36 months
30.5.d The designated accessible stall is incorrectly configured as an ambulatory stall, and there is no standard accessible stall provided. TR2 36 months
30.6 Men’s toilet room:    
30.6.a The toilet room sign is mounted on the door and has no raised or Braille characters. TR11 12 months
30.6.b The door is inaccessible because it requires 9 pounds of force to open. D3 12 months
30.6.c Although an audible alarm is provided in this facility, there is no visual alarm appliance in the toilet room. AL1 36 months
30.6.d The lavatory is inaccessible because the top of the rim or counter is 35 3/4 inches high. LS3 36 months
30.6.e The urinal is inaccessible because the rim is 23 1/2 inches high and the flush control is 50 inches high. TR8 36 months
30.6.f The designated accessible stall is incorrectly configured as an ambulatory stall, and there is no standard accessible stall provided. TR2 36 months
31. Baldwin Fire Station #46, 610 Oliver Street (exterior only)
31.1 Parking: There is no designated accessible parking provided. P1 36 months
31.2 Entrances:    
31.2.a The doors are inaccessible because there are thresholds more than 3/4 inches high. D12 24 months
31.2.b The doors are inaccessible because knob hardware is used. D2 12 months
31.2.c The mailbox next to one entrance protrudes into the walkway and is not detectable to blind persons using a cane. AR7 24 months
32. Mandarin Senior Center, 3848 Hartley Road
32.1 Curb ramp: The curb ramp leading to the entrance ramp is inaccessible because the side flares have slopes of 25.1% and 17.9%. AR4 36 months
32.2 Entrance ramp: The ramp is inaccessible because it has a slope of up to 10.2%. R4 36 months
32.3 Interior doors: The doors throughout the facility are inaccessible because knob hardware is used. D2 12 months
32.4 Computer room: The pull side of the door, which is accessed through a front approach, is inaccessible because it has only 15 inches of clear space on the latch side. D5 24 months
32.5 Drinking fountain by toilet rooms:    
32.5.a The drinking fountain is inaccessible because the controls require 10 pounds of force to operate. DF2 24 months
32.5.b Although a designated accessible drinking fountain is provided, there is no drinking fountain provided for people who have difficulty bending or stooping. DF3 12 months
32.6 Women’s toilet room with stalls:    
32.6.a The toilet room sign is mounted on the door and has no raised or Braille characters. TR11 12 months
32.6.b The door is inaccessible because it requires 11 pounds of force to open. D3 12 months
32.6.c The paper towel dispenser is inaccessible because it is mounted with the controls 55 inches high. CT4 12 months
32.6.d The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact. LS2 12 months
32.6.e The designated accessible stall is incorrectly configured as an ambulatory stall, and there is no standard accessible stall provided. TR2 36 months
32.7 Men’s toilet room with stalls:    
32.7.a The toilet room sign is mounted on the door and has no raised or Braille characters. TR11 12 months
32.7.b The door is inaccessible because it requires 13 pounds of force to open. D3 12 months
32.7.c The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact. LS2 12 months
32.7.d The urinal is inaccessible because the rim is 24 1/2 inches high and the flush control is 51 1/2 inches high. TR8 36 months
32.7.e The designated accessible stall is incorrectly configured as an ambulatory stall, and there is no standard accessible stall provided. TR2 36 months
32.8 Rear door: The door is inaccessible because there is a slope of 9.7% within the door’s required maneuvering clearance. D7 36 months
32.9 Entrance to billiard building: The door is inaccessible because there is a slope of 6.9% within the door’s required maneuvering clearance. D7 36 months
32.10 Card / game building:    
32.10.a The entrance door is inaccessible because knob hardware is used. D2 12 months
32.10.b The route through the building is inaccessible because the halls are only 34 1/2 inches wide. AR2 12 months
32.10.c The drinking fountain is inaccessible because the controls require 7 pounds of force to operate. DF2 24 months
32.10.d Although a designated accessible drinking fountain is provided, there is no drinking fountain provided for people who have difficulty bending or stooping. DF3 12 months
32.11 Card / game building single-user toilet room:    
32.11.a The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact. LS2 12 months
32.11.b The toilet paper dispenser in the designated accessible stall is inaccessible because it is mounted more than 9 inches from the front of the toilet. TR6 12 months
32.11.c The side grab bar at the toilet is inaccessible because it is mounted 37 inches high with the closer end 12 1/2 inches from the rear wall, and the space between the grab bar and the wall is 2¼ inches. TR16 12 months
32.11.d The rear grab bar at the toilet is inaccessible because it is mounted 36 3/4 inches high and the space between rear grab bar and wall is 2 1/4 inches. TR13 12 months
33. Mandarin Library, 3330 Kori Street
33.1 Parking:    
33.1.a The built-up curb ramps impermissibly extend into the required parking spaces. AR4 36 months
33.1.b The parking lot, with a total of 77 parking spaces, is inaccessible because there are only 2 designated accessible spaces, and one of the signs is mounted too low. This lot requires 1 van accessible space and 3 standard accessible spaces. P1 36 months
33.2 Library:    
33.2.a The book depository is inaccessible because it is 55 inches high. CT4 12 months
33.2.b The magazine displays are inaccessible because the maximum reach ranges are 55 3/4 inches high. CT4 12 months
33.3 Drinking fountain by community room:    
33.3.a The drinking fountain is inaccessible because the controls require 7 pounds of force to operate. DF2 24 months
33.3.b Although a designated accessible drinking fountain is provided, there is no drinking fountain provided for people who have difficulty bending or stooping. DF3 12 months
33.4 Large community room:    
33.4.a The door is inaccessible because it requires 12 pounds of force to open. D3 12 months
33.4.b The stage is inaccessible because there is a step to access it. AR2 24 months
33.4.c The room is inaccessible to people with hearing disabilities because there is no assistive listening system provided. This room requires 7 receivers. AA4 36 months
33.5 Small office: The door is inaccessible because knob hardware is used. D2 12 months
33.6 Women’s toilet room with stalls:    
33.6.a The toilet room sign is mounted on the door and has no raised or Braille characters. TR11 12 months
33.6.b The door is inaccessible because it requires 15 pounds of force to open. D3 12 months
33.6.c No accessible mirror has been provided. TR5 12 months
33.6.d The lavatory is inaccessible because it has twist-type hardware. LS4 12 months
33.6.e The designated accessible stall is incorrectly configured as an ambulatory stall, and there is no standard accessible stall provided. TR2 24 months
33.7 Men’s toilet room with stalls:    
33.7.a The toilet room sign is mounted on the door and has no raised or Braille characters. TR11 12 months
33.7.b The door is inaccessible because it requires 17 pounds of force to open. D3 12 months
33.7.c The urinal is inaccessible because the rim is 23 inches high. TR8 36 months
33.7.d The designated accessible stall is incorrectly configured as an ambulatory stall, and there is no standard accessible stall provided. TR2 24 months
34. Maxville Community Center, 18065 Pennsylvania Avenue
34.1 Entrance ramp: The ramp is inaccessible because it lacks handrails. R3 24 months
34.2 Interior doors: The doors throughout the facility are inaccessible because knob hardware is used. D2 12 months
34.3 Women’s toilet room with stalls:    
34.3.a The toilet room sign is mounted on the door and has no raised or Braille characters. TR11 12 months
34.3.b The toilet room entrance doors are inaccessible because they require 7 and 9 pounds of force to open. D3 12 months
34.3.c The pull side of the interior door, which is accessed through a front approach, is inaccessible because it lacks adequate maneuvering clearance. D5 12 months
34.3.d The door is inaccessible because the vestibule is not sufficiently deep. D4 12 months
34.3.e No accessible mirror has been provided. TR5 12 months
34.3.f The toilet is inaccessible because the seat is 20 inches high. TR9 24 months
34.3.g The side grab bar at the designated accessible toilet is inaccessible because it is 36 inches long. TR16 12 months
34.3.h The designated accessible toilet is inaccessible because the side grab bar is mounted 32 inches high. ST12 12 months
34.3.i The rear grab bar at the toilet is inaccessible because it is 18 inches long and it is mounted 10 inches from the side wall. TR13 12 months
34.4 Men’s toilet room with stalls:    
34.4.a The toilet room sign is mounted on the door and has no raised or Braille characters. TR11 12 months
34.4.b The toilet room entrance doors are inaccessible because they each require 7 pounds of force to open. D3 12 months
34.4.c The pull side of the exterior door, which is accessed through a front approach, is inaccessible because it lacks adequate maneuvering clearance. D5 12 months
34.4.d The door is inaccessible because the vestibule is not sufficiently deep. D4 12 months
34.4.e No accessible mirror has been provided. TR5 12 months
34.4.f The urinal is inaccessible because the rim is 25 inches high. TR8 36 months
34.4.g The designated accessible stall is inaccessible because the flush control is on the closed side. TR4 24 months
34.4.h The side grab bar at the toilet is inaccessible because it is 36 inches long. TR13 12 months
34.4.i The rear grab bar at the toilet is inaccessible because it is 18 inches long and it is mounted 9 inches from the side wall. TR13 12 months
34.5 Drinking fountain outside kitchen:    
34.5.a The wall-mounted drinking fountain is inaccessible because it provides only 23 inches of clear knee height. DF4 24 months
34.5.b Although a designated accessible drinking fountain is provided, there is no drinking fountain provided for people who have difficulty bending or stooping. DF3 12 months
34.6 Picnic Shelters:    
34.6.a There is no accessible route to the grills because the grass is not firm, stable, and slip resistant. AR1 36 months
34.6.b The picnic tables are inaccessible because none provide the required knee space. DW1 24 months
35. Burnett Park, 3740 Burnett Park Road
35.1 Drinking fountain near concession stand: The drinking fountain is inaccessible because the spout is 41 inches high, and the controls require 10 pounds of force to operate. DF1 24 months
35.2 Concession stand:    
35.2.a The concession stand counter is inaccessible because it is 41 inches high. C1 24 months
35.2.b The counter protrudes into the walkway and is not detectable to blind persons using a cane. AR7 24 months
35.2.c The picnic table is inaccessible because it does not provide the required knee space. DW1 24 months
35.3 Ballfield by concession stand:    
35.3.a The door to the home team dugout is inaccessible because the opening is only 28 inches wide. D14 24 months
35.3.b The pull side of the door to the batting cages, which is accessed through a front approach, is inaccessible because it has only no clear space on the latch side. D5 24 months
35.4 Drinking fountain by toilet rooms:    
35.4.a The drinking fountain is inaccessible because the water flow is less than 4 inches high. DF5 12 months
35.4.b The drinking fountain is inaccessible because the controls require 8 pounds of force to operate. DF2 24 months
35.4.c Although a designated accessible drinking fountain is provided, there is no drinking fountain provided for people who have difficulty bending or stooping. DF3 12 months
35.5 Women’s toilet room with stalls by ballfields    
35.5.a The toilet room sign is mounted on the door and has no raised or Braille characters. TR11 12 months
35.5.b The door is inaccessible because it requires 10 pounds of force to open. D3 12 months
35.5.c Although an audible alarm is provided in this facility, there is no visual alarm appliance in the toilet room. AL1 36 months
35.5.d The lavatory is inaccessible because it has twist-type hardware. LS4 24 months
35.5.e No accessible coat hook has been provided. TR3 12 months
35.5.f The side grab bar at the toilet is inaccessible because it is mounted 17 inches from the rear wall. TR16 12 months
35.6 Men’s toilet room by ballfields:    
35.6.a The toilet room sign is mounted on the door and has no raised or Braille characters. TR11 12 months
35.6.b The toilet room was locked and could not be surveyed. TR1 36 months
35.7 Picnic pavilion:    
35.7.a The routes to the grills are inaccessible because the grass is not firm, stable, and slip resistant. AR1 36 months
35.7.b The picnic tables are inaccessible because none provide the required knee space. DW1 24 months
35.8 Drinking fountain by picnic area:    
35.8.a The drinking fountain is inaccessible because the controls require 13 pounds of force to operate. DF2 24 months
35.8.b The drinking fountains protrude into the walkway and are not detectable to blind persons using a cane. AR7 24 months
36. Burnett Park Community Center, 3740 Burnett Park Road
36.1 Interior doors: The doors throughout the facility are inaccessible because knob hardware is used. D2 12 months
36.2 Drinking fountain by toilet room:    
36.2.a The drinking fountain is inaccessible because the controls require 16 pounds of force to operate. DF2 24 months
36.2.b Although a designated accessible drinking fountain is provided, there is no drinking fountain provided for people who have difficulty bending or stooping. DF3 12 months
36.2.c The drinking fountain unit protrudes into the walkway and is not detectable to blind persons using a cane. AR7 24 months
36.3 Men’s toilet room with stalls:    
36.3.a The door is inaccessible because it requires 15 pounds of force to open. D3 12 months
36.3.b No accessible mirror has been provided. TR5 12 months
36.3.c The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact. LS2 12 months
36.3.d The toilet room door swings into the required clear floor space at the lavatory. TR6 24 months
36.3.e The route to the urinal is inaccessible because it is only 29 inches wide. AR3 12 months
36.3.f The designated accessible toilet stall is inaccessible because it is 53 inches long and 53 inches wide. TR23 12 months
36.3.g The toilet paper dispenser in the designated accessible stall is inaccessible because it is mounted more than 9 inches from the front of the toilet, and is on the wall opposite the side grab bar. TR6 12 months
36.3.h The side grab bar at the toilet is inaccessible because it is mounted 32 3/4 inches high with its far end 49 1/2 inches from the rear wall, and the space between the grab bar and the wall is 2 1/2 inches. TR16 12 months
36.4 Women’s toilet room with stalls:    
36.4.a The toilet room sign is mounted on the hinge side of the door. TR11 12 months
36.4.b The door is inaccessible because it requires 14 pounds of force to open. D3 12 months
36.4.c No accessible mirror has been provided. TR5 12 months
36.4.d The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact. LS2 12 months
36.4.e The lavatory is inaccessible because it has insufficient clear floor space. LS5 36 months
36.4.f The route to the lavatory is inaccessible because it is only 29 inches wide. AR3 12 months
36.4.g The designated accessible stall is incorrectly configured as an ambulatory stall, and there is no standard accessible stall provided. TR2 12 months
37. Westbrook Library, 2809 Commonwealth Avenue. (Also used for polling)
37.1 Parking:    
37.1.a The parking lot is inaccessible because there are no access aisles. P2 36 months
37.1.b The parking signage is inaccessible because it is obstructed by trees. M1 12 months
37.1.c The designated accessible parking is inaccessible because it lacks van accessible signage. P3 12 months
37.2 Route from the parking lot to the main entrance: The route is inaccessible because it is not firm, stable or slip resistant and has not been maintained. AR1, M1 36 months
37.3 Exterior exit door:    
37.3.a The door is inaccessible because there is a .75 inch high threshold that is not beveled. D12 24 months
37.3.b The door is inaccessible because knob hardware is used. D2 12 months
37.4 Computer stations tables: The computer and card catalog are inaccessible because the bottom edge of their table is 25 inches high. C1 12 months
37.5 Route from the main library area to the toilet rooms: The route is inaccessible because it is obstructed by a book cart and the path is 27 inches wide. AR1 12 months
37.6 Men’s single user toilet room:    
37.6.a The door is inaccessible because it requires 11 pounds of force to open. D3 12 months
37.6.b The pull side of the door, which is accessed from the latch side of the door, is inaccessible because it is obstructed by a book cart and the path is 27 inches wide. D5 12 months
37.6.c The toilet room is inaccessible because the clear floor space is obstructed by a trash can. SU16 12 months
37.6.d The toilet is inaccessible because the rear grab bar is obstructed by the soap dispenser. TR15 12 months
37.6.e The toilet is inaccessible because the rear grab bar is 31 inches long. TR14 12 months
37.6.f The toilet is inaccessible because the flush control is on the closed side. TR4 24 months
37.6.g The toilet paper dispenser in the designated accessible stall is inaccessible because it is mounted more than 9 inches from the front of the toilet. TR6 12 months
37.7 Women’s single user toilet room:    
37.7.a The door is inaccessible because it requires 11 pounds of force to open. D3 12 months
37.7.b The pull side of the door, which is accessed from the latch side of the door, is inaccessible because it is obstructed by a book cart and the path is 27 inches wide D5 12 months
37.7.c The toilet is inaccessible because the rear grab bar is obstructed by the soap dispenser. TR15 12 months
37.8 Computer and conference room:    
37.8.a The door is inaccessible because the pull side is obstructed by a book truck. D18 12 months
37.8.b The door is inaccessible because it requires 12 pounds of force to open. D3 12 months
37.8.c The door is inaccessible because knob hardware is used. D2 12 months

Return to Settlement