ATTACHMENT J: Modifications to Altered FacilitiesPlease Note: Paragraph 52 of the Settlement Agreement requires that within twenty-four months of the effective date of this Agreement, the City provide signage as necessary to comply with 28 C.F.R. §35.163(b), after having surveyed all facilities that are the subject of this Agreement for the purpose of identifying those that have multiple entrances not all of which are accessible. The chart below lists the facilities surveyed by the Department, the access issues identified during the survey, and the actions required to correct the access issues. Required actions are listed using an alphanumeric code. The key to the alphanumeric codes is provided in Attachment M to this Agreement. In order to ensure that the following spaces and elements in the City’s facilities in which alterations occurred after January 26, 1992, are readily accessible to and usable by persons with disabilities, the City will take the actions referenced by the alphanumeric code and described in detail in Attachment M to this Settlement Agreement within the time period specified below, which time period will begin to run on the effective date of this Agreement. |
|||
Item # |
Access Issue |
Required Action |
Completion Date |
---|---|---|---|
1. |
Memorial Hall and Civic Center, located at 410 Pennsylvania Avenue |
||
1.1. |
Parking. The designated accessible parking is inaccessible because it lacks van accessible signage. |
P6 |
24 months |
1.2. |
Route to Entrance. The curb ramp leading to the accessible entrance doors is inaccessible because it has a slope of 9.8%. |
AR5 |
24 months |
1.3. |
Entrances. The building does not have directional signage posted at inaccessible entrances and does not have the International Symbol of Accessibility posted at accessible entrances. |
D16 |
24 months |
1.4. |
Banquet Room. There is no signage informing the public of the availability of an assistive listening system. |
AA3 |
24 months |
1.5. |
Lower Level Unisex Single User Toilet Room |
||
1.5.a. |
The toilet room sign is mounted on the hinged side of the door. |
TR18 |
24 months |
1.5.b. |
No accessible mirror has been provided. |
TR14 |
24 months |
1.5.c. |
The side grab bar at the toilet is inaccessible because it is mounted with the far end 49½ inches from the rear wall. |
SU5 |
24 months |
1.5.d. |
The rear grab bar at the toilet is inaccessible because it is mounted 8 inches from the side wall. |
SU3 |
24 months |
1.6. |
Lower Level Dressing Rooms. None of the dressing rooms is accessible because there is no accessible signage provided and none of the dressing rooms has an accessible mirror or closet. |
LR2, S1 |
24 months |
1.7. |
Lower Level Unisex Single User Toilet and Shower Room near Dressing Room |
||
1.7.a. |
The side grab bar at the toilet is inaccessible because it is mounted with the far end 50 inches from the rear wall. |
SU5 |
24 months |
1.7.b. |
The rear grab bar at the toilet is inaccessible because it is mounted 8 inches from the side wall. |
SU3 |
24 months |
1.7.c. |
The shower is inaccessible because the controls are located more than 27 inches from the wall on which the transfer seat is mounted, and there is an 1 inch high curb at the entrance. |
B8 |
24 months |
1.8. |
Veteran’s Room 106/108. There is no signage informing the public of the availability of an assistive listening system. |
AA3 |
24 months |
1.9. |
Elevator |
||
1.9.a. |
The elevator is inaccessible because the hoist way signage is mounted at 41 inches high. |
E12 |
24 months |
1.9.b. |
The elevator is inaccessible because it does not automatically reopen without contact for obstructions between 5 inches and 29 inches above the finished floor. |
E6 |
24 months |
1.9.c. |
The elevator is inaccessible because the emergency system requires voice communication to operate. |
E8 |
24 months |
1.10. |
Lower Level Route near Elevator. The AED machine protrudes into the walkway and is not detectable to blind persons using a cane. |
AR8 |
24 months |
1.11. |
Lower Level Men’s Toilet Room with Showers near Room 110 |
||
1.11.a. |
No accessible mirror has been provided. |
TR14 |
24 months |
1.11.b. |
The lower urinal is inaccessible because the rim is 20 inches high. |
TR20 |
24 months |
1.11.c. |
The designated accessible stall is incorrectly configured as an ambulatory stall, and there is no standard accessible stall provided. |
ST15 |
24 months |
1.11.d. |
There is no accessible shower provided. |
B8 |
24 months |
1.12. |
Lower Level Women’s Toilet Room with Showers near Room 110 |
||
1.12.a. |
No accessible mirror has been provided. |
TR14 |
24 months |
1.12.b. |
The lavatory is inaccessible because the top of the rim is 35 inches high. |
TR11 |
24 months |
1.12.c. |
The designated accessible stall is incorrectly configured as an ambulatory stall, and there is no standard accessible stall provided. |
ST15 |
24 months |
1.13. |
Memorial Hall |
24 months |
|
1.13.a. |
Memorial Hall, containing 1058 seats, is inaccessible because there are no fixed companion seats provided. |
AA6 |
24 months |
1.13.b. |
There is no signage informing the public of the availability of an assistive listening system. |
AA3 |
24 months |
1.13.c. |
The ramp to the stage is inaccessible because it has a slope of up to 17%, there is a handrail on only one side, and the ends of the handrail lack extensions and are not rounded or returned. |
R5 |
24 months |
1.13.d. |
The route to the stage is inaccessible because there less than 74 inches of head room provided. |
AR7 |
24 months |
1.14. |
Stage Area Unisex Single User Toilet Room |
||
1.14.a. |
The toilet paper dispenser is inaccessible because it is mounted 41 inches from the rear wall. |
SU17 |
24 months |
1.14.b. |
The side grab bar at the toilet is inaccessible because it is mounted with the far end 49 inches from the rear wall. |
SU6 |
24 months |
1.15. |
2nd Floor Women’s Toilet Room with Stalls |
||
1.15.a. |
The lavatory is inaccessible because the bottom of the apron is 27 inches high. |
TR11 |
24 months |
1.15.b. |
No accessible coat hook has been provided. |
TR1 |
24 months |
1.15.c. |
The toilet paper dispenser in the designated accessible stall is inaccessible because it is mounted 37½ inches from the rear wall. |
ST19 |
24 months |
1.15.d. |
The side grab bar at the designated accessible toilet is inaccessible because it is mounted with the far end 50 inches from the rear wall. |
ST7 |
24 months |
1.15.e. |
The rear grab bar at the designated accessible toilet is inaccessible because it is mounted 8 inches from the side wall. |
ST4 |
24 months |
1.15.f. |
Although there are 12 toilet stalls, there is no ambulatory stall provided. |
ST1 |
24 months |
1.16. |
2nd Floor Drinking Fountain |
||
1.16.a. |
The drinking fountain is inaccessible because the flow of water is 1 inch high. |
DF7 |
24 months |
1.16.b. |
The wall-mounted drinking fountain is inaccessible because it provides only 24 inches of clear knee height. |
DF5 |
24 months |
1.16.c. |
Although a designated accessible drinking fountain is provided, there is no drinking fountain provided for people who have difficulty bending or stooping. |
DF3 |
24 months |
1.17. |
2nd Floor Men’s Toilet Room with Stalls |
||
1.17.a. |
The urinal is inaccessible because the rim is 19 inches high. |
TR20 |
24 months |
1.17.b. |
The designated accessible stall is incorrectly configured as an ambulatory stall, and there is no standard accessible stall provided. |
ST15 |
24 months |