ATTACHMENT K: Program Access in Existing Facilities

Please Note: Paragraph of the Agreement requires that within three months of the effective date of this Agreement, the County will provide signage as necessary to comply with 28 C.F.R. § 35.163(b), after having surveyed all facilities that are the subject of this Agreement for the purpose of identifying those that have multiple entrances not all of which are accessible.

The technical requirements and, where appropriate, the scoping requirements of the Standards are used as a guide for determining whether a program or activity held in an existing facility is "readily accessible to and usable by" persons with disabilities and for determining what changes are necessary to make this program or activity accessible if it continues to be provided in the existing facility in question. See 28 C.F.R. §§ 35.150(b)(1), 35.151.

The chart below lists the facilities surveyed by the Department, the access issues identified during the survey, and the actions required to correct the access issues. Required actions are listed using an alphanumeric code. The key to the alphanumeric codes is provided in Attachment M to this Agreement.

In order to ensure that the programs, services, and activities housed in the County's facilities are accessible to persons with disabilities, when viewed in their entirety, the County will take the actions referenced by the alphanumeric code and described in detail in Attachment M to this Settlement Agreement within the time period specified below, which time period begins to run on the effective date of the Agreement.

Item #

Access Issue

Required Action

Completion Date

1.

Sheriff's Office – Airport Division

1.1

Parking

1.1.a

The parking lot, with a total of 47 parking spaces, is inaccessible because it only has 1 space designated as accessible. This lot requires 1 van accessible space and 1 standard accessible space.

P3

24 months

1.1.b

The parking reserved for persons with disabilities is inaccessible because the access aisle width is 62 inches.

P8

24 months

2

Easton Community Center

2.1

Parking

2.1.a

The parking lot is inaccessible because, although there is vertical signage for one van-accessible space, there are no pavement markings. This lot requires 1 van accessible space.

P3

24 months

2.2

Unisex Single-User Toilet Room

2.2.a

There is no toilet room signage.

TR17

24 months

2.2.b

No accessible coat hook has been provided.

TR1

24 months

2.2.c

The toilet paper dispenser is inaccessible because it is mounted 40 inches from the rear wall.

SU17

24 months

2.2.d

The side grab bar at the toilet is inaccessible because it is 36 inches long and it is mounted with its farther end 48 inches from the rear wall.

SU6

24 months

2.2.e

The rear grab bar at the toilet is inaccessible because it is 24 inches long.

SU3

24 months

2.2.f

Multi-use Room with Stage

2.2.g

There is no accessible route connecting the stage with the main floor nor the side room.

AA1

24 months

2.2.h

The door leading to the side room on one side of the stage is inaccessible because it has an opening width of 29 inches.

D25

24 months

2.2.i

The door leading to the side room on one side of the stage is inaccessible because knob hardware is used.

D1

24 months

2.2.j

The stage is inaccessible to people who are hard of hearing because there is no assistive listening system provided. This stage requires 2 receivers.

AA5

24 months

3

Eldersville Community Center

3.1

Parking

3.1.a

The parking lot is inaccessible because there are no access aisles.

P1

24 months

3.1.b

Exterior accessible Route

3.1.c

There is no accessible route to the outdoor picnic area or play area.

PD1

24 months

3.2

Dining Area

3.2.a

The coat rack is inaccessible because the rod is mounted 62 inches above the finished floor.

L2

24 months

3.3

Women's Single-User Toilet Room

3.3.a

No accessible coat hook has been provided.

TR1

24 months

3.3.b

The toilet is inaccessible because its centerline is 19.5 inches from the side wall.

SU15

24 months

3.3.c

The toilet paper dispenser is inaccessible because it is mounted 44 inches from the rear wall.

SU17

24 months

3.3.d

The rear grab bar at the toilet is inaccessible because it is 24 inches long and mounted with its farther end 30 inches from the side wall.

SU3

24 months

3.4

Men's Single-user Toilet Room

3.4.a

The toilet room contains a number of inaccessible elements and is not accessible to people with disabilities.

SU13

24 months

4

Garfield Hill Community Center

4.1

Unisex Single-User Toilet Room

4.1.a

The toilet is inaccessible because its centerline is 17 inches from the side wall.

SU15

24 months

4.1.b

The toilet paper dispenser is inaccessible because it is mounted 37 inches from the rear wall.

SU17

24 months

4.1.c

The rear grab bar at the toilet is inaccessible because it is 24 inches long.

SU3

24 months

5

Gladewater City Hall (Polling Only)

5.1

Entrance

5.1.a

The door is inaccessible because there is a slope of 6.9% within the door's required maneuvering clearance.

D13

24 months

5.2

Interior Ramp

5.2.a

The ramp is inaccessible because it lacks level landings at the top and bottom that are at least 60 inches deep.

R5

24 months

5.2.b

The ramp is inaccessible because the handrails are mounted at 31 inches above the walking surface, and ends of the handrails are not rounded or returned.

R4

24 months

5.3

Interior accessible Route

5.3.a

The route at the overhead "Exit" sign near the interior ramp is inaccessible because there are only 78 inches of head room provided.

AR7

24 months

5.4

Polling Area

5.4.a

The entrance door leading to the room used for polling is inaccessible because knob hardware is used.

D1

24 months

6

Gladewater Commerce Street Building

6.1

Parking

6.1.a

The parking lot, with a total of 17 parking spaces and one standard accessible parking space reserved for use by persons with disabilities, is inaccessible because it does not have a designated van-accessible parking space. This lot requires 1 van accessible space.

P3

24 months

6.2

Exterior Entrance to Tax Accessor and Justice of the Peace

6.2.a

The door is inaccessible because there is a 1 inch high threshold.

D23

24 months

6.3

Justice of the Peace Court

6.3.a

The exterior entrance door is inaccessible because there is a 1 inch high threshold.

D23

24 months

6.3.b

The doors leading to the courtroom and judge's chambers are inaccessible because knob hardware is used.

D1

24 months

6.3.c

The lobby drinking fountain is inaccessible because the water height is 2 inches, the pressure required to operate the control is 7 pounds, the knee space height is 26.5 inches, and the knee space depth is 8 inches.

DF1

24 months

6.4

Unisex Single-User Toilet Room

6.4.a

The toilet room sign has no raised or Braille characters.

TR17

24 months

6.4.b

The door is inaccessible because it has an opening width of 30 inches.

D25

24 months

6.4.c

The toilet room door swings into the required clear floor space at the lavatory.

TR6

24 months

6.4.d

The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact.

TR12

24 months

6.4.e

The toilet is inaccessible because its centerline is 14 inches from the side wall.

SU15

24 months

6.4.f

The toilet paper dispenser is inaccessible because it is mounted 38 inches from the rear wall.

SU17

24 months

6.4.g

The grab bars at the toilet are inaccessible because they are mounted 36.5 inches above the finished floor.

SU11

24 months

7

Gregg County Airport

7.1

Parking

7.1.a

The parking lot, with a total of 150 parking spaces, is inaccessible because it only has 3 spaces designated as accessible, the signs can be obstructed by cars parked in these spaces, the pavement markings are not clear, and there is no van-accessible signage. This lot requires 1 van accessible space and 4 standard accessible spaces.

P3

24 months

7.2

Women's Toilet Room with Stalls; First Floor

7.2.a

Although an audible alarm is provided in this facility, there is no visual alarm appliance in the toilet room.

TR21

24 months

7.2.b

The lavatory is inaccessible because the bottom of the apron is 22 inches above the finished floor, there is inadequate knee / toe clearance, and the hot water pipes are not covered or otherwise configured to protect against contact.

TR9

24 months

7.2.c

The designated accessible stall is incorrectly configured as an ambulatory stall, and there is no standard accessible stall provided.

ST15

24 months

7.3

Men's Toilet Room with Stalls; First Floor

7.3.a

Although an audible alarm is provided in this facility, there is no visual alarm appliance in the toilet room.

TR21

24 months

7.3.b

The lavatory is inaccessible because the bottom of the apron is 22 inches above the finished floor, there is inadequate knee / toe clearance, and the hot water pipes are not covered or otherwise configured to protect against contact.

TR9

24 months

7.3.c

The urinal is inaccessible because the rim is 19 inches above the finished floor, the flush control is 46 inches above the finished floor, and there is inadequate clear floor space centered at the urinal.

TR20

24 months

7.3.d

The designated accessible stall is incorrectly configured as an ambulatory stall, and there is no standard accessible stall provided.

ST15

24 months

7.4

Drinking Fountain; First Floor

7.4.a

The drinking fountain is inaccessible because the flow of water is 1 inch high.

DF7

24 months

7.4.b

The drinking fountain protrudes into the walkway and is not detectable to blind persons using a cane.

AR8

24 months

7.5

Car Rental Counters

7.5.a

The counters are inaccessible because they are 49 inches above the finished floor.

C6

24 months

7.6

Airline Ticketing Counter

7.6.a

The counter is inaccessible because it is 49 inches above the finished floor.

C6

24 months

7.7

Accessible Route to Security Point

7.7.a

The route is inaccessible because it is only 33 inches wide at the side metal detector area (for wheelchairs) and 30 inches area at the main metal detector area. AR3

7.8

Airport Restaurant

7.8.a

The dining area is inaccessible because access aisles along the tables are only 31 inches wide.

PD7

24 months

7.9

Elevators

7.9.a

The elevator is inaccessible because the hall call buttons are centered at 39 inches above the finished floor.

E3

24 months

7.9.b

The elevator is inaccessible because the car position indicators do not emit a visual signal as the car passes or stops at a floor.

E5

24 months

7.9.c

The elevator is inaccessible because the emergency system is not identified by raised symbols and letterings.

E8

24 months

8

Hugh Camp Park Office Building (Polling Only)

8.1

Parking

8.1.a

The parking lot, with a total of 6 parking spaces of which one is designated as a standard accessible space, is inaccessible because it has no van-accessible space and lacks signage. This lot requires 1 van accessible space.

P3

24 months

9

Hugh Camp Memorial Park

9.1

Picnic Area

9.1.a

The picnic tables are inaccessible because none provide the required knee space.

PD6

24 months

9.2

Accessible Route to Grilling Area

9.2.a

The route to the grilling area is inaccessible because there are several changes in level and there is broken concrete throughout the route.

AR1

24 months

9.3

Accessible Route to Play Area

9.3.a

The route to the play area is inaccessible because there is a change level and it has a maximum slope of 14.1%.

AR1

24 months

9.4

Women's Single-User Toilet Room

9.4.a

The route to the women's toilet room is inaccessible because there are steps at the entrance.

AR1

24 months

9.4.b

The toilet room contains a number of inaccessible elements and is not accessible to people with disabilities.

ST14

24 months

9.5

Men's Single-User Toilet Room

9.5.a

The route to the men's toilet room is inaccessible because there are steps at the entrance.

AR1

24 months

9.5.b

The toilet room contains a number of inaccessible elements and is not accessible to people with disabilities.

ST14

24 months

10

Judson Community Center

10.1

Parking

10.1.a

One of the parking reserved for persons with disabilities is inaccessible because it lacks appropriate vertical signage.

P6

24 months

10.2

Main Entrance

10.2.a

The interior main entrance door (in a series) is inaccessible because it requires 10 pounds of force to open.

D2

24 months

10.3

Ramp

10.3.a

The ramp is inaccessible because it has a slope of up to 8.3%.

R5

24 months

10.3.b

The ramp is inaccessible because the handrails height is 27 inches, the handrails lack 12 inch extensions at the top and the bottom of the ramp, and the ends of the handrails are not rounded or returned.

R4

24 months

10.4

Drinking Fountain

10.4.a

The drinking fountain is inaccessible because the flow of water is 3 inches high.

DF7

24 months

10.4.b

The wall-mounted drinking fountain is inaccessible because it provides only 14 inches of clear knee depth.

DF5

24 months

10.5

Men's Toilet Room with Stalls

10.5.a

The entrance door is inaccessible because it requires 6 pounds of force to open.

D2

24 months

10.5.b

The lavatory is inaccessible because the bottom of the apron is 27 inches above the finished floor.

TR11

24 months

10.5.c

The urinal is inaccessible because there is inadequate clear floor space in front of the unit.

TR20

24 months

10.5.d

The designated accessible toilet is inaccessible because the flush control is on the closed side.

ST2

24 months

10.5.e

The toilet paper dispenser in the designated accessible stall is inaccessible because it is mounted 45 inches from the rear wall.

ST19

24 months

10.5.f

The designated accessible toilet stall is inaccessible because it is less than 59 inches long and 60 inches wide because the stall door swings into the stall.

ST16

24 months

10.6

Women's Toilet Room with Stalls

10.6.a

The toilet room is inaccessible because there is insufficient turning space provided within the room.

TR19

24 months

10.6.b

The lavatory is inaccessible because the bottom of the apron is 27 inches above the finished floor and the lavatory has a clear floor space of only 28 by 28 inches.

TR11

24 months

10.6.c

The designated accessible toilet is inaccessible because the flush control is on the closed side.

ST2

24 months

10.6.d

The toilet paper dispenser in the designated accessible stall is inaccessible because it is mounted 45 inches from the rear wall.

ST19

24 months

11

Kilgore Office and Community Building

11.1

Exterior ramp at East Entrance

11.1.a

The ramp is inaccessible because it has a slope of up to 10.3% and a cross-slope of up to 3.0%.

R5

24 months

11.1.b

The ramp is inaccessible because it does not have edge protection at the drop off sides.

R1

24 months

11.1.c

The ramp is inaccessible because the ends of the handrails are not rounded or returned, the handrails height is 32 inches, and the handrails lack 12 inch extensions at the top and bottom of the ramp.

R4

24 months

11.2

Exterior Entrance - East Entrance

11.2.a

The double doors are inaccessible because each leaf is 30 inches wide.

D24

24 months

11.3

Justice of the Peace Office

11.3.a

The entrance door is inaccessible because it requires 11 pounds of force to open.

D2

24 months

11.4

Justice of the Peace Court

11.4.a

The judge's bench and witness stand are inaccessible because they can be accessed only by steps.

AA8

24 months

11.4.b

The entrance door is inaccessible because it has an opening width of 30 inches.

D25

24 months

11.4.c

The entrance door is inaccessible because it requires 11 pounds of force to open.

D2

24 months

11.4.d

The courtroom is inaccessible because the tables do not provide the required knee space.

PD3

24 months

11.5

Judge's Office

11.5.a

The entrance door is inaccessible because it has an opening width of 30.75 inches.

D25

24 months

11.6

Community Room Men's Toilet Room with Stalls

11.6.a

The entrance door is inaccessible because it requires 7 pounds of force to open.

D2

24 months

11.6.b

The lavatory is inaccessible because it has twist-type hardware.

TR10

24 months

11.6.c

The designated accessible toilet is inaccessible because its centerline is 19 inches from the side wall.

ST17

24 months

11.6.d

The designated accessible toilet is inaccessible because the flush control is on the closed side.

ST2

24 months

11.6.e

The toilet paper dispenser in the designated accessible stall is inaccessible because it is mounted 37.5 inches from the rear wall.

ST19

24 months

11.6.f

The side grab bar at the designated accessible toilet is inaccessible because it is obstructed by the toilet paper dispenser.

ST8

24 months

11.6.g

The stall door swings into the required clear floor space at the lavatory.

TR6

24 months

11.7

Community Room Women's Toilet Room with Stalls

11.7.a

The toilet seat cover dispenser is inaccessible because it is mounted 60 inches above the finished floor behind the toilet.

TR4

24 months

11.7.b

The lavatory is inaccessible because it has twist-type hardware.

TR10

24 months

11.7.c

The designated accessible toilet is inaccessible because its centerline is 16.5 inches from the side wall.

ST17

24 months

11.7.d

The side grab bar at the designated accessible toilet is inaccessible because it is obstructed by the toilet paper dispenser.

ST8

24 months

12

Liberty City Community Building

12.1

Accessible Route from parking lot to entrance

12.1.a

The route is inaccessible because there is uneven asphalt paving at the beginning of the sidewalk from the parking lot.

AR1

24 months

12.2

Exterior Entrances

12.2.a

The building does not have directional signage posted at inaccessible entrances and does not have the International Symbol of Accessibility posted at accessible entrances.

D16

24 months

12.3

Dining Area

12.3.a

The entry door is inaccessible because knob hardware is used.

D1

24 months

12.4

Women's Single-User Toilet Room

12.4.a

The toilet room sign is mounted on the door.

TR17

24 months

12.4.b

The toilet is inaccessible because its centerline is 21 inches from the side wall.

SU15

24 months

12.4.c

The toilet is inaccessible because the flush control is on the closed side.

SU1

24 months

12.4.d

The toilet paper dispenser is inaccessible because it is mounted 41 inches from the rear wall.

SU17

24 months

12.5

Men's Single-User Toilet Room

12.5.a

The toilet room sign is mounted on the door.

TR17

24 months

12.5.b

The toilet is inaccessible because its centerline is 17 inches from the side wall.

SU15

24 months

12.5.c

The toilet paper dispenser is inaccessible because it is mounted 44 inches from the rear wall.

SU17

24 months

12.5.d

The rear grab bar at the toilet is inaccessible because it is 24 inches long.

SU3

24 months

12.6

Meeting Room

12.6.a

The entry door is inaccessible because it requires 10 pounds of force to open.

D2

24 months

12.7

Auditorium

12.7.a

There is no accessible route connecting the wheelchair seating areas and the stage.

AA1

24 months

12.7.b

The ramp leading from the entrance to the seating areas is inaccessible because it lacks handrails.

R4

24 months

13

Longview Eastman Road Building

13.1

Parking

13.1.a

The parking reserved for persons with disabilities is inaccessible because the signs are mounted too low.

P6

24 months

13.1.b

The parking reserved for persons with disabilities is inaccessible because it is not located on the shortest accessible route to the accessible facility entrance.

P5

24 months

13.2

Exterior Entrance

13.2.a

The door is inaccessible because knob hardware is used.

D1

24 months

13.3

Women's Single-User Toilet Room

13.3.a

The toilet room sign is mounted on the door.

TR17

24 months

13.3.b

The door is inaccessible because it has an opening width of 31 inches.

D25

24 months

13.3.c

The door is inaccessible because it requires 12 pounds of force to open.

D2

24 months

13.3.d

No accessible mirror has been provided.

TR14

24 months

13.3.e

The toilet is inaccessible because its centerline is 19 inches from the side wall.

SU15

24 months

13.3.f

The side grab bar at the toilet is inaccessible because it is mounted with its farther end 48.5 inches from the rear wall.

SU6

24 months

13.3.g

The rear grab bar at the toilet is inaccessible because it is 33 inches long.

SU3

24 months

13.4

Men's Single-User Toilet Room

13.4.a

The toilet room sign is mounted on the door.

TR17

24 months

13.4.b

The door is inaccessible because it has an opening width of 31 inches.

D25

24 months

13.4.c

The door is inaccessible because it requires 11 pounds of force to open.

D2

24 months

13.4.d

No accessible mirror has been provided.

TR14

24 months

13.4.e

The toilet is inaccessible because its centerline is 18.5 inches from the side wall.

SU15

24 months

13.4.f

The side grab bar at the toilet is inaccessible because it is mounted with its farther end 48 inches from the rear wall.

SU6

24 months

13.4.g

The rear grab bar at the toilet is inaccessible because it is 33 inches long.

SU3

24 months

13.4.h

The toilet paper dispenser is inaccessible because it is mounted 48 inches from the rear wall and above the side grab bar.

SU17

24 months

13.5

Drinking fountain

13.5.a

The drinking fountain is inaccessible because it has a spout that is 38 inches above the finished floor.

DF6

24 months

13.5.b

The drinking fountain is inaccessible because the flow of water is 1 inch high.

DF7

24 months

14

Olivia R. Hilburn Community Building

14.1

Parking

14.1.a

The parking reserved for persons with disabilities is inaccessible because it lacks appropriate vertical signage.

P6

24 months

14.2

Exterior Entrance

14.2.a

The door is inaccessible because there is a slope of 6.6% at the top landing of the ramp which is within the door's required maneuvering clearance.

D13

24 months

14.2.b

The entrance is inaccessible because the vestibule in between the glass storm door and the main entrance door is not sufficiently deep.

D3

24 months

14.3

Ramp at rear of building

14.3.a

The ramp is inaccessible because its top landing (within the exterior entrance door's required maneuvering clearance) is 6.6%.

R3

24 months

14.4

Women's Single-User Toilet Room

14.4.a

The pull side of the door, which is accessed through a front approach, is inaccessible because it has only 10 inches of clear space on the latch side.

D6

24 months

14.4.b

The toilet paper dispenser is inaccessible because it is mounted 37 inches from the rear wall.

SU17

14.4.c

The rear grab bar at the toilet is inaccessible because it is 24 inches long.

SU3

24 months

14.5

Men's Single-User Toilet Room

14.5.a

The pull side of the door, which is accessed through a front approach, is inaccessible because it has only 10 inches of clear space on the latch side.

D6

24 months

14.5.b

The toilet is inaccessible because the flush control is on the closed side.

SU1

24 months

14.5.c

The toilet paper dispenser is inaccessible because it is mounted 42 inches from the rear wall.

SU17

24 months

14.5.d

The rear grab bar at the toilet is inaccessible because it is 24 inches long.

SU3

24 months

15

Road and Bridge-Precinct 1-Commissioner's Office

15.1

Parking

15.1.a

The parking lot, with a total of 6 parking spaces, is inaccessible because it has no spaces designated as accessible. This lot requires 1 van accessible space.

P3

24 months

15.2

Exterior Entrance

15.2.a

The pull side of the entrance door, which is accessed through a front approach, is inaccessible because a chair obstructs the clear space on the latch side.

D6

24 months

15.2.b

The door is inaccessible because knob hardware is used.

D1

24 months

15.3

Unisex Single-User Toilet Room

15.3.a

The toilet room sign is mounted on the door and has no raised or Braille characters.

TR17

24 months

15.3.b

The door is inaccessible because it has an opening width of only 30 inches.

D25

24 months

15.3.c

The door is inaccessible because it requires 25 pounds of force to open.

D2

24 months

15.3.d

No accessible mirror has been provided.

TR14

24 months

15.3.e

The lavatory is inaccessible because it has twist-type hardware.

TR10

24 months

15.3.f

The toilet is inaccessible because its centerline is 17 inches from the side wall.

SU15

24 months

15.3.g

The toilet is inaccessible because the flush control is on the closed side.

SU1

24 months

15.3.h

The rear grab bar at the toilet is inaccessible because its closer end is mounted 13 inches from the side wall.

SU3

24 months

16

Road and Bridge-Precinct 2-Commissioner's Office (Community Center and Tax Office Attached to Building)

16.1

Overall Parking

16.1.a

The parking reserved for persons with disabilities is inaccessible because the access aisle is 74 inches wide.

P8

24 months

16.2

Ramps Leading to Justice of the Peace, Commissioner and Constable's Office

16.2.a

The upper ramp leading to the Commissioner Office is inaccessible because it has a cross-slope of up to 2.4%.

R5

24 months

16.2.b

The upper ramps leading to the Commissioner Office and Constable's Office are inaccessible because they lack handrails on one side of the ramp and handrail extensions at the top of the ramps.

R4

24 months

16.3

Justice of the Peace Office

16.3.a

The jury box is inaccessible because it can be accessible only by steps, and the route narrows to a width of 21 inches.

AA8

24 months

16.3.b

The witness stand is inaccessible because it can be accessible only by steps, and the route narrows to a width of 28 inches.

AA8

24 months

16.4

Justice of the Peace Office Courtroom single-user toilet room

16.4.a

The toilet is inaccessible because the flush control is on the closed side.

SU1

24 months

16.4.b

The side grab bar at the toilet is inaccessible because it is mounted with its farther end 47 inches from the rear wall.

SU6

24 months

16.4.c

The rear grab bar at the toilet is inaccessible because it is 24 inches long and mounted with its farther end 30 inches from the side wall.

SU3

24 months

16.5

Tax Office - Parking

16.5.a

The parking reserved for persons with disabilities is inaccessible because the access aisle is 64 inches wide.

P8

24 months

16.6

Tax Office - Exterior Entrance

16.6.a

The door is inaccessible because it has an opening width of only 30 inches.

D25

24 months

16.6.b

The door is inaccessible because there is a 1 inch high threshold.

D23

24 months

16.7

Tax Office - Interior Ramp

16.7.a

The ramp is inaccessible because it slopes up to 13.4%, and the top landing is not level.

R5

24 months

16.7.b

The ramp is inaccessible because it lacks handrails on one side.

R4

24 months

16.7.c

The ramp is inaccessible because it does not have edge protection at the drop off sides.

R1

24 months

16.8

Community Center (Polling Also) Telephone

16.8.a

The telephone is inaccessible because its clear floor space is 10 inches wide, and it lacks volume control.

TT1

24 months

16.9

Community Center Coat Rack

16.9.a

The coat rack is inaccessible because it is mounted with the rack 68 inches above the finished floor.

TR5

24 months

16.1

Community Center Exterior Ramp

16.10.a

The ramp is inaccessible because it lacks handrails.

R4

24 months

16.10.b

The ramp is inaccessible because it does not have edge protection at the drop off sides.

R1

24 months

16.11

Community Center Interior Ramp leading to Unisex Single-User Toilet Room

16.11.a

The ramp is inaccessible because it slopes up to 10.8%.

R5

24 months

16.11.b

The ramp is inaccessible because it lacks handrails.

R4

24 months

16.12

Community Center Unisex Single-User Toilet Room

16.12.a

The entry door is inaccessible because there is a slope of 10.8 within the door's required maneuvering clearance due to an interior ramp.

D13

24 months

16.12.b

The toilet room sign is mounted with its centerline at 64 inches above the floor.

TR17

24 months

16.12.c

The soap dispenser is inaccessible because it is mounted with the controls 49 inches above the finished floor with forward reach required.

TR5

24 months

16.12.d

The toilet is inaccessible because its centerline is 19.5 inches from the side wall.

SU15

24 months

16.12.e

The toilet is inaccessible because the flush control is on the closed side.

SU1

24 months

16.12.f

The toilet paper dispenser is inaccessible because it is mounted 39 inches from the rear wall.

SU17

24 months

16.12.g

The side grab bar at the toilet is inaccessible because it is mounted with its farther end 48 inches from the rear wall.

SU6

24 months

16.13

Kitchen

16.13.a

The route to the kitchen is inaccessible because there are several steps leading to the kitchen.

AR2

24 months

17

Road and Bridge-Precinct 3-Commissioner's Office

17.1

Parking

17.1.a

The parking lot, with a total of 6 parking spaces, is inaccessible because it lacks a van-accessible parking space. This lot requires 1 van accessible space.

P3

24 months

17.1.b

The parking reserved for persons with disabilities is inaccessible because it slopes 2.4%.

P7

24 months

17.2

Exterior Route

17.2.a

The route from the parking lot to the entrance is inaccessible because there is a 7.1% slope and a 2.1% cross-slope at one point along the route.

AR1

24 months

17.3

Exterior Entrance

17.3.a

The door is inaccessible because there is a 1 inch high threshold.

D23

24 months

17.3.b

The door is inaccessible because knob hardware is used.

D1

24 months

17.4

Women's Toilet Room with Stalls

17.4.a

The toilet room contains a number of inaccessible elements and is not accessible to people with disabilities.

ST14

24 months

17.5

Men's Toilet Room with Stalls

17.5.a

The toilet room contains a number of inaccessible elements and is not accessible to people with disabilities.

ST14

24 months

18

Road and Bridge-Precinct 4-Commissioner's Office

18.1

Parking

18.1.a

The parking lot, with a total of 15 parking spaces, is inaccessible because there is no van-accessible parking space, and the designated accessible spaces slope 3.2% - 3.6% and do not have clear pavement markings. This lot requires 1 van accessible space.

P3

24 months

18.1.b

The route from the parking lot to the entrance is inaccessible because there is a slope of 5.5% in front of the exterior entrance.

AR1

24 months

18.2

Exterior Entrance

18.2.a

The exterior entrance door is inaccessible because there is a slope of 5.5% within the door's required maneuvering clearance.

D13

24 months

18.2.b

The entrance doors (exterior and interior) are inaccessible because knob hardware is used.

D1

24 months

18.2.c

The entrance is inaccessible because there is a 1 inch high threshold.

D23

24 months

18.3

Lobby

18.3.a

The entry door is inaccessible because knob hardware is used.

D1

24 months

18.4

Commissioner's Office

18.4.a

The entry door is inaccessible because knob hardware is used.

D1

24 months

18.5

Unisex Single-User Toilet Room

18.5.a

The toilet room contains a number of inaccessible elements and is not accessible to people with disabilities.

ST14

24 months

19

Service Center Building

19.1

Parking

19.1.a

The parking lot, with a total of 12 parking spaces, is inaccessible because there is no van-accessible parking space, the designated accessible spaces and access aisles slope 2.6% with a cross-slope of 3.7%. This lot requires 1 van accessible space.

P3

24 months

19.2

Exterior Ramp

19.2.a

The route is inaccessible because there is a 1 inch lip at the bottom edge of the ramp.

AR1

24 months

19.2.b

The ramp is inaccessible because it does not have edge protection at the drop off sides.

R1

24 months

19.2.c

The ramp is inaccessible because it lacks level landings at the top and bottom.

R5

24 months

19.2.d

The ramp is inaccessible because it lacks a handrail on one side, the ends of the handrail are not rounded or returned, and the handrail is mounted at 32.5 inches height.

R4

24 months

19.3

Exterior Entrance

19.3.a

The building does not have directional signage posted at inaccessible entrances and does not have the International Symbol of Accessibility posted at accessible entrances.

D16

24 months

19.4

Interior doors throughout facility

19.4.a

The doors are inaccessible because knob hardware is used.

D1

24 months

19.5

Women's Toilet Room with Stalls

19.5.a

The toilet room sign is mounted on the door and has no raised or Braille characters.

TR17

24 months

19.5.b

The door is inaccessible because it has an opening width of only 29.5 inches.

D25

24 months

19.5.c

The door is inaccessible because it requires 12 pounds of force to open.

D2

24 months

19.5.d

The pull side of the door, which is accessed through a front approach, is inaccessible because it has only 2 inches of clear space on the latch side.

D6

24 months

19.5.e

The push side of the door, which is accessed through a front approach and which has both a closer and a latch, is inaccessible because it has only 2 inches of clear space on the latch side.

D7

24 months

19.5.f

The light switch dispenser is inaccessible because it is mounted with the controls 55 inches above the finished floor.

TR5

24 months

19.5.g

The seat cover dispenser is inaccessible because it is mounted with the controls 53 inches above the finished floor.

TR5

24 months

19.5.h

The towel dispenser is inaccessible because it is mounted with the controls 56 inches above the finished floor.

TR5

24 months

19.5.i

The lavatory is inaccessible because the top of the rim or counter is 29 inches above the finished floor, bottom of the apron is 26.5 inches above the finished floor, and its knee / toe clearances do not comply.

TR11

24 months

19.5.j

The lavatory is inaccessible because it has twist-type hardware.

TR10

24 months

19.5.k

The designated accessible toilet is inaccessible because its centerline is 17.5 inches from the side wall.

ST17

24 months

19.5.l

No accessible coat hook has been provided. TR1

19.5.m

The side grab bar at the designated accessible toilet is inaccessible because it is 39 inches long and it is mounted with its farther end 42 inches from the rear wall.

ST7

24 months

19.5.n

The side grab bar at the designated accessible toilet is inaccessible because it is obstructed by the toilet paper dispenser.

ST9

24 months

19.5.o

The rear grab bar at the designated accessible toilet is inaccessible because it is 19 inches long.

ST4

24 months

19.5.p

The designated accessible toilet is inaccessible because the rear grab bar is obstructed by the flush valve.

ST5

24 months

19.5.q

The stall door is inaccessible because twist hardware is used.

D1

24 months

19.6

Men's Toilet Room with Stalls

19.6.a

The toilet room sign is mounted on the door and has no raised or Braille characters.

TR17

24 months

19.6.b

The door is inaccessible because it has an opening width of only 29 inches.

D25

24 months

19.6.c

The door is inaccessible because it requires 12 pounds of force to open.

D2

24 months

19.6.d

The pull side of the door, which is accessed through a front approach, is inaccessible because it has only 2 inches of clear space on the latch side.

D6

24 months

19.6.e

The push side of the door, which is accessed through a front approach and which has both a closer and a latch, is inaccessible because it has only 2 inches of clear space on the latch side.

D7

24 months

19.6.f

The light switch dispenser is inaccessible because it is mounted with the controls 54 inches above the finished floor.

TR5

24 months

19.6.g

The towel dispenser is inaccessible because it is mounted with the controls 55 inches above the finished floor.

TR5

24 months

19.6.h

The lavatory is inaccessible because the top of the rim or counter is 29 inches above the finished floor, the bottom of the apron is 26.5 inches above the finished floor, and its knee / toe clearances do not comply.

TR11

24 months

19.6.i

The lavatory is inaccessible because it has twist-type hardware.

TR10

24 months

19.6.j

The urinal is inaccessible because the rim is 21.5 inches above the finished floor.

TR20

24 months

19.6.k

The designated accessible toilet is inaccessible because the top of the seat is 19.5 inches above the finished floor.

ST20

24 months

19.6.l

No accessible coat hook has been provided.

TR1

24 months

19.6.m

The side grab bar at the designated accessible toilet is inaccessible because it is 39 inches long and it is mounted with its farther end 42 inches from the rear wall.

ST7

24 months

19.6.n

The side grab bar at the designated accessible toilet is inaccessible because it is obstructed by the toilet paper dispenser.

ST9

24 months

19.6.o

The rear grab bar at the designated accessible toilet is inaccessible because it is 19 inches long.

ST4

24 months

19.6.p

The designated accessible toilet is inaccessible because the rear grab bar is obstructed by the flush valve.

ST5

24 months

19.6.q

The stall door is inaccessible because twist hardware is used.

D1

24 months

19.7

Drinking Fountain Near Room 103

19.7.a

The drinking fountain is inaccessible because it has a spout that is 37 inches above the finished floor.

DF6

24 months

19.8

Community Room - Hallway entrance

19.8.a

The door is inaccessible because it has an opening width of only 28.5 inches.

D25

24 months

20

Community Room - Room entrance

20.1

The door is inaccessible because it has an opening width of only 27 inches.

D25

24 months

20.2

The door is inaccessible because it requires 9 pounds of force to open.

D2

24 months

21

Community Room - Kitchen

21.1

The door is inaccessible because it has an opening width of only 28.5 inches.

D25

24 months

22

Community Room - Stage

22.1

There is no accessible route connecting the wheelchair seating areas and the stage.

AA1

24 months

23

South Street Community Center (Polling Only)

23.1

Parking

23.1.a

The parking lot is inaccessible because spaces and access aisles are not marked. This lot requires 1 van accessible space and 1 standard space.

P3

24 months

24

Youth Detention Center

24.1

Parking

24.1.a

The parking lot, with a total of 75 parking spaces, is inaccessible because it has 3 spaces designated as accessible but none are designated as van-accessible. This lot requires 1 van accessible space and 2 standard spaces.

P3

24 months

24.1.b

The parking reserved for persons with disabilities is inaccessible because the signs are mounted too low.

P6

24 months

24.1.c

The parking reserved for persons with disabilities is inaccessible because the pavement marking is not clear.

P7

24 months

24.2

Accessible Route from curb ramp to front entrance

24.2.a

The route is inaccessible because it has a slope of at least 9.6%.

AR1

24 months

24.3

Juvenile Detention - Lobby

24.3.a

The interior door is inaccessible because it requires 7 pounds of force to open.

D2

24 months

24.3.b

The interior door is inaccessible because knob hardware is used.

D1

24 months

24.3.c

The interior room signage provided throughout the facility is inaccessible because it does not have raised and Braille characters.

D26

24 months

24.4

Juvenile Detention - Intake Office

24.4.a

The door is inaccessible because it requires 7 pounds of force to open.

D2

24 months

24.5

Juvenile Detention - Attorney Counseling Office

24.5.a

The doors are inaccessible because knob hardware is used.

D1

24 months

24.6

Juvenile Detention - Cells

24.6.a

There is no accessible cell provided.

PJ1

24 months

24.7

Juvenile Detention - Classroom B

24.7.a

The door is inaccessible because it requires 9 pounds of force to open.

D2

24 months

24.8

Juvenile Detention - Unisex Locker Room

24.8.a

There is no signage.

TR17

24 months

24.8.b

The door is inaccessible because it requires 11 pounds of force to open.

D2

24 months

24.8.c

No accessible mirror has been provided.

TR14

24 months

24.8.d

The toilet is inaccessible because the top of the seat is 20 inches above the finished floor.

SU18

24 months

24.8.e

The toilet is inaccessible because its centerline is 19.5 inches from the side wall.

SU15

24 months

24.8.f

The side grab bar at the toilet is inaccessible because it is 24 inches long and it is mounted with its farther end 26 inches from the rear wall.

SU6

24 months

24.8.g

There is no accessible shower provided.

B8

24 months

24.9

Women's Single-User Toilet Room Near Lobby

24.9.a

The signage is inaccessible.

TR17

24 months

24.9.b

The door is inaccessible because it requires 6 pounds of force to open.

D2

24 months

24.9.c

The door is inaccessible because knob hardware is used.

D1

24 months

24.9.d

The push side of the door, which is accessed from the latch side of the door, is inaccessible because it has only 9 inches of clear space on the latch side.

D11

24 months

24.9.e

The lavatory is inaccessible because the top of the counter is 36 inches above the finished floor.

TR11

24 months

24.9.f

The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact.

TR12

24 months

24.9.g

The toilet is inaccessible because its centerline is 19.5 inches from the side wall.

SU15

24 months

24.1

Men's Single-User Toilet Room Near Lobby

24.10.a

The signage is inaccessible.

TR17

24 months

24.10.b

The door is inaccessible because it requires 6 pounds of force to open.

D2

24 months

24.10.c

The door is inaccessible because knob hardware is used.

D1

24 months

24.10.d

The lavatory is inaccessible because the top of the counter is 36 inches above the finished floor.

TR11

24 months

24.10.e

The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact.

TR12

24 months

24.10.f

The toilet is inaccessible because its centerline is 19.5 inches from the side wall.

SU15

24 months

24.10.g

The side grab bar at the toilet is inaccessible because it is obstructed by the toilet seat cover dispenser. SU8

24.11

Probation Center - Entrance

24.11.a

The interior door is inaccessible because it requires 13 pounds of force to open.

D2

24 months

24.12

Probation Center - Men's Toilet Room with Stalls

24.12.a

The signage is inaccessible.

TR17

24 months

24.12.b

The door is inaccessible because it requires 11 pounds of force to open.

D2

24.12.c

Although an audible alarm is provided in this facility, there is no visual alarm appliance in the toilet room.

TR21

24 months

24.12.d

No accessible mirror has been provided.

TR14

24 months

24.12.e

The lavatory is inaccessible because the top of the counter is 35.25 inches above the finished floor.

TR11

24 months

24.12.f

The lavatory is inaccessible because it has inadequate clear floor space.

TR8

24 months

24.12.g

The lavatory is inaccessible because it has twist-type hardware.

TR10

24 months

24.12.h

The urinal is inaccessible because the rim is 19 inches above the finished floor, the flush control height is 47 inches, and the clear floor space width is 26.5 inches.

TR20

24 months

24.12.i

The designated accessible stall is incorrectly configured as an ambulatory stall, and there is no standard accessible stall provided.

ST15

24 months

24.13

Probation Center - Women's Toilet Room with Stalls

24.13.a

The signage is inaccessible.

TR17

24 months

24.13.b

The door is inaccessible because it requires more than 5 pounds of force to open.

D2

24 months

24.13.c

Although an audible alarm is provided in this facility, there is no visual alarm appliance in the toilet room.

TR21

24 months

24.13.d

The seat cover dispenser is inaccessible because it is mounted with the controls 58 inches above the finished floor.

TR5

24 months

24.13.e

The paper towel dispenser is inaccessible because it is mounted 49 inches above the finished floor behind the counter.

TR4

24 months

24.13.f

The lavatory is inaccessible because the top of the counter is 36.25 inches above the finished floor.

TR11

24 months

24.13.g

The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact.

TR12

24 months

24.13.h

The stall door is inaccessible because twisting is required.

D1

24 months

24.13.i

The designated accessible stall is incorrectly configured as an ambulatory stall, and there is no standard accessible stall provided.

ST15

24 months

24.14

Probation Center - Waiting Room

24.14.a

The door is inaccessible because knob hardware is used.

D1

24 months

24.15

Probation Center - Interview Room

24.15.a

The doors are inaccessible because knob hardware is used.

D1

24 months

24.16

Probation Center - Conference Room

24.16.a

The door is inaccessible because knob hardware is used.

D1

24 months

 

 

 