ATTACHMENT K: Program Access in Existing Facilities Please Note: Paragraph of the Agreement requires that within three months of the effective date of this Agreement, the County will provide signage as necessary to comply with 28 C.F.R. § 35.163(b), after having surveyed all facilities that are the subject of this Agreement for the purpose of identifying those that have multiple entrances not all of which are accessible. The technical requirements and, where appropriate, the scoping requirements of the Standards are used as a guide for determining whether a program or activity held in an existing facility is "readily accessible to and usable by" persons with disabilities and for determining what changes are necessary to make this program or activity accessible if it continues to be provided in the existing facility in question. See 28 C.F.R. §§ 35.150(b)(1), 35.151. The chart below lists the facilities surveyed by the Department, the access issues identified during the survey, and the actions required to correct the access issues. Required actions are listed using an alphanumeric code. The key to the alphanumeric codes is provided in Attachment M to this Agreement. In order to ensure that the programs, services, and activities housed in the County's facilities are accessible to persons with disabilities, when viewed in their entirety, the County will take the actions referenced by the alphanumeric code and described in detail in Attachment M to this Settlement Agreement within the time period specified below, which time period begins to run on the effective date of the Agreement. |
|||
Item # |
Access Issue |
Required Action |
Completion Date |
---|---|---|---|
1. |
Sheriff's Office – Airport Division |
||
1.1 |
Parking |
|
|
1.1.a |
The parking lot, with a total of 47 parking spaces, is inaccessible because it only has 1 space designated as accessible. This lot requires 1 van accessible space and 1 standard accessible space. |
P3 |
24 months |
1.1.b |
The parking reserved for persons with disabilities is inaccessible because the access aisle width is 62 inches. |
P8 |
24 months |
2 |
Easton Community Center |
||
2.1 |
Parking |
||
2.1.a |
The parking lot is inaccessible because, although there is vertical signage for one van-accessible space, there are no pavement markings. This lot requires 1 van accessible space. |
P3 |
24 months |
2.2 |
Unisex Single-User Toilet Room |
||
2.2.a |
There is no toilet room signage. |
TR17 |
24 months |
2.2.b |
No accessible coat hook has been provided. |
TR1 |
24 months |
2.2.c |
The toilet paper dispenser is inaccessible because it is mounted 40 inches from the rear wall. |
SU17 |
24 months |
2.2.d |
The side grab bar at the toilet is inaccessible because it is 36 inches long and it is mounted with its farther end 48 inches from the rear wall. |
SU6 |
24 months |
2.2.e |
The rear grab bar at the toilet is inaccessible because it is 24 inches long. |
SU3 |
24 months |
2.2.f |
Multi-use Room with Stage |
||
2.2.g |
There is no accessible route connecting the stage with the main floor nor the side room. |
AA1 |
24 months |
2.2.h |
The door leading to the side room on one side of the stage is inaccessible because it has an opening width of 29 inches. |
D25 |
24 months |
2.2.i |
The door leading to the side room on one side of the stage is inaccessible because knob hardware is used. |
D1 |
24 months |
2.2.j |
The stage is inaccessible to people who are hard of hearing because there is no assistive listening system provided. This stage requires 2 receivers. |
AA5 |
24 months |
3 |
Eldersville Community Center |
||
3.1 |
Parking |
||
3.1.a |
The parking lot is inaccessible because there are no access aisles. |
P1 |
24 months |
3.1.b |
Exterior accessible Route |
||
3.1.c |
There is no accessible route to the outdoor picnic area or play area. |
PD1 |
24 months |
3.2 |
Dining Area |
||
3.2.a |
The coat rack is inaccessible because the rod is mounted 62 inches above the finished floor. |
L2 |
24 months |
3.3 |
Women's Single-User Toilet Room |
||
3.3.a |
No accessible coat hook has been provided. |
TR1 |
24 months |
3.3.b |
The toilet is inaccessible because its centerline is 19.5 inches from the side wall. |
SU15 |
24 months |
3.3.c |
The toilet paper dispenser is inaccessible because it is mounted 44 inches from the rear wall. |
SU17 |
24 months |
3.3.d |
The rear grab bar at the toilet is inaccessible because it is 24 inches long and mounted with its farther end 30 inches from the side wall. |
SU3 |
24 months |
3.4 |
Men's Single-user Toilet Room |
||
3.4.a |
The toilet room contains a number of inaccessible elements and is not accessible to people with disabilities. |
SU13 |
24 months |
4 |
Garfield Hill Community Center |
||
4.1 |
Unisex Single-User Toilet Room |
||
4.1.a |
The toilet is inaccessible because its centerline is 17 inches from the side wall. |
SU15 |
24 months |
4.1.b |
The toilet paper dispenser is inaccessible because it is mounted 37 inches from the rear wall. |
SU17 |
24 months |
4.1.c |
The rear grab bar at the toilet is inaccessible because it is 24 inches long. |
SU3 |
24 months |
5 |
Gladewater City Hall (Polling Only) |
||
5.1 |
Entrance |
||
5.1.a |
The door is inaccessible because there is a slope of 6.9% within the door's required maneuvering clearance. |
D13 |
24 months |
5.2 |
Interior Ramp |
||
5.2.a |
The ramp is inaccessible because it lacks level landings at the top and bottom that are at least 60 inches deep. |
R5 |
24 months |
5.2.b |
The ramp is inaccessible because the handrails are mounted at 31 inches above the walking surface, and ends of the handrails are not rounded or returned. |
R4 |
24 months |
5.3 |
Interior accessible Route |
||
5.3.a |
The route at the overhead "Exit" sign near the interior ramp is inaccessible because there are only 78 inches of head room provided. |
AR7 |
24 months |
5.4 |
Polling Area |
||
5.4.a |
The entrance door leading to the room used for polling is inaccessible because knob hardware is used. |
D1 |
24 months |
6 |
Gladewater Commerce Street Building |
||
6.1 |
Parking |
||
6.1.a |
The parking lot, with a total of 17 parking spaces and one standard accessible parking space reserved for use by persons with disabilities, is inaccessible because it does not have a designated van-accessible parking space. This lot requires 1 van accessible space. |
P3 |
24 months |
6.2 |
Exterior Entrance to Tax Accessor and Justice of the Peace |
||
6.2.a |
The door is inaccessible because there is a 1 inch high threshold. |
D23 |
24 months |
6.3 |
Justice of the Peace Court |
||
6.3.a |
The exterior entrance door is inaccessible because there is a 1 inch high threshold. |
D23 |
24 months |
6.3.b |
The doors leading to the courtroom and judge's chambers are inaccessible because knob hardware is used. |
D1 |
24 months |
6.3.c |
The lobby drinking fountain is inaccessible because the water height is 2 inches, the pressure required to operate the control is 7 pounds, the knee space height is 26.5 inches, and the knee space depth is 8 inches. |
DF1 |
24 months |
6.4 |
Unisex Single-User Toilet Room |
||
6.4.a |
The toilet room sign has no raised or Braille characters. |
TR17 |
24 months |
6.4.b |
The door is inaccessible because it has an opening width of 30 inches. |
D25 |
24 months |
6.4.c |
The toilet room door swings into the required clear floor space at the lavatory. |
TR6 |
24 months |
6.4.d |
The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact. |
TR12 |
24 months |
6.4.e |
The toilet is inaccessible because its centerline is 14 inches from the side wall. |
SU15 |
24 months |
6.4.f |
The toilet paper dispenser is inaccessible because it is mounted 38 inches from the rear wall. |
SU17 |
24 months |
6.4.g |
The grab bars at the toilet are inaccessible because they are mounted 36.5 inches above the finished floor. |
SU11 |
24 months |
7 |
Gregg County Airport |
||
7.1 |
Parking |
||
7.1.a |
The parking lot, with a total of 150 parking spaces, is inaccessible because it only has 3 spaces designated as accessible, the signs can be obstructed by cars parked in these spaces, the pavement markings are not clear, and there is no van-accessible signage. This lot requires 1 van accessible space and 4 standard accessible spaces. |
P3 |
24 months |
7.2 |
Women's Toilet Room with Stalls; First Floor |
||
7.2.a |
Although an audible alarm is provided in this facility, there is no visual alarm appliance in the toilet room. |
TR21 |
24 months |
7.2.b |
The lavatory is inaccessible because the bottom of the apron is 22 inches above the finished floor, there is inadequate knee / toe clearance, and the hot water pipes are not covered or otherwise configured to protect against contact. |
TR9 |
24 months |
7.2.c |
The designated accessible stall is incorrectly configured as an ambulatory stall, and there is no standard accessible stall provided. |
ST15 |
24 months |
7.3 |
Men's Toilet Room with Stalls; First Floor |
||
7.3.a |
Although an audible alarm is provided in this facility, there is no visual alarm appliance in the toilet room. |
TR21 |
24 months |
7.3.b |
The lavatory is inaccessible because the bottom of the apron is 22 inches above the finished floor, there is inadequate knee / toe clearance, and the hot water pipes are not covered or otherwise configured to protect against contact. |
TR9 |
24 months |
7.3.c |
The urinal is inaccessible because the rim is 19 inches above the finished floor, the flush control is 46 inches above the finished floor, and there is inadequate clear floor space centered at the urinal. |
TR20 |
24 months |
7.3.d |
The designated accessible stall is incorrectly configured as an ambulatory stall, and there is no standard accessible stall provided. |
ST15 |
24 months |
7.4 |
Drinking Fountain; First Floor |
||
7.4.a |
The drinking fountain is inaccessible because the flow of water is 1 inch high. |
DF7 |
24 months |
7.4.b |
The drinking fountain protrudes into the walkway and is not detectable to blind persons using a cane. |
AR8 |
24 months |
7.5 |
Car Rental Counters |
||
7.5.a |
The counters are inaccessible because they are 49 inches above the finished floor. |
C6 |
24 months |
7.6 |
Airline Ticketing Counter |
||
7.6.a |
The counter is inaccessible because it is 49 inches above the finished floor. |
C6 |
24 months |
7.7 |
Accessible Route to Security Point |
||
7.7.a |
The route is inaccessible because it is only 33 inches wide at the side metal detector area (for wheelchairs) and 30 inches area at the main metal detector area. AR3 |
||
7.8 |
Airport Restaurant |
||
7.8.a |
The dining area is inaccessible because access aisles along the tables are only 31 inches wide. |
PD7 |
24 months |
7.9 |
Elevators |
||
7.9.a |
The elevator is inaccessible because the hall call buttons are centered at 39 inches above the finished floor. |
E3 |
24 months |
7.9.b |
The elevator is inaccessible because the car position indicators do not emit a visual signal as the car passes or stops at a floor. |
E5 |
24 months |
7.9.c |
The elevator is inaccessible because the emergency system is not identified by raised symbols and letterings. |
E8 |
24 months |
8 |
Hugh Camp Park Office Building (Polling Only) |
||
8.1 |
Parking |
||
8.1.a |
The parking lot, with a total of 6 parking spaces of which one is designated as a standard accessible space, is inaccessible because it has no van-accessible space and lacks signage. This lot requires 1 van accessible space. |
P3 |
24 months |
9 |
Hugh Camp Memorial Park |
||
9.1 |
Picnic Area |
||
9.1.a |
The picnic tables are inaccessible because none provide the required knee space. |
PD6 |
24 months |
9.2 |
Accessible Route to Grilling Area |
||
9.2.a |
The route to the grilling area is inaccessible because there are several changes in level and there is broken concrete throughout the route. |
AR1 |
24 months |
9.3 |
Accessible Route to Play Area |
||
9.3.a |
The route to the play area is inaccessible because there is a change level and it has a maximum slope of 14.1%. |
AR1 |
24 months |
9.4 |
Women's Single-User Toilet Room |
||
9.4.a |
The route to the women's toilet room is inaccessible because there are steps at the entrance. |
AR1 |
24 months |
9.4.b |
The toilet room contains a number of inaccessible elements and is not accessible to people with disabilities. |
ST14 |
24 months |
9.5 |
Men's Single-User Toilet Room |
||
9.5.a |
The route to the men's toilet room is inaccessible because there are steps at the entrance. |
AR1 |
24 months |
9.5.b |
The toilet room contains a number of inaccessible elements and is not accessible to people with disabilities. |
ST14 |
24 months |
10 |
Judson Community Center |
||
10.1 |
Parking |
||
10.1.a |
One of the parking reserved for persons with disabilities is inaccessible because it lacks appropriate vertical signage. |
P6 |
24 months |
10.2 |
Main Entrance |
||
10.2.a |
The interior main entrance door (in a series) is inaccessible because it requires 10 pounds of force to open. |
D2 |
24 months |
10.3 |
Ramp |
||
10.3.a |
The ramp is inaccessible because it has a slope of up to 8.3%. |
R5 |
24 months |
10.3.b |
The ramp is inaccessible because the handrails height is 27 inches, the handrails lack 12 inch extensions at the top and the bottom of the ramp, and the ends of the handrails are not rounded or returned. |
R4 |
24 months |
10.4 |
Drinking Fountain |
||
10.4.a |
The drinking fountain is inaccessible because the flow of water is 3 inches high. |
DF7 |
24 months |
10.4.b |
The wall-mounted drinking fountain is inaccessible because it provides only 14 inches of clear knee depth. |
DF5 |
24 months |
10.5 |
Men's Toilet Room with Stalls |
||
10.5.a |
The entrance door is inaccessible because it requires 6 pounds of force to open. |
D2 |
24 months |
10.5.b |
The lavatory is inaccessible because the bottom of the apron is 27 inches above the finished floor. |
TR11 |
24 months |
10.5.c |
The urinal is inaccessible because there is inadequate clear floor space in front of the unit. |
TR20 |
24 months |
10.5.d |
The designated accessible toilet is inaccessible because the flush control is on the closed side. |
ST2 |
24 months |
10.5.e |
The toilet paper dispenser in the designated accessible stall is inaccessible because it is mounted 45 inches from the rear wall. |
ST19 |
24 months |
10.5.f |
The designated accessible toilet stall is inaccessible because it is less than 59 inches long and 60 inches wide because the stall door swings into the stall. |
ST16 |
24 months |
10.6 |
Women's Toilet Room with Stalls |
||
10.6.a |
The toilet room is inaccessible because there is insufficient turning space provided within the room. |
TR19 |
24 months |
10.6.b |
The lavatory is inaccessible because the bottom of the apron is 27 inches above the finished floor and the lavatory has a clear floor space of only 28 by 28 inches. |
TR11 |
24 months |
10.6.c |
The designated accessible toilet is inaccessible because the flush control is on the closed side. |
ST2 |
24 months |
10.6.d |
The toilet paper dispenser in the designated accessible stall is inaccessible because it is mounted 45 inches from the rear wall. |
ST19 |
24 months |
11 |
Kilgore Office and Community Building |
||
11.1 |
Exterior ramp at East Entrance |
||
11.1.a |
The ramp is inaccessible because it has a slope of up to 10.3% and a cross-slope of up to 3.0%. |
R5 |
24 months |
11.1.b |
The ramp is inaccessible because it does not have edge protection at the drop off sides. |
R1 |
24 months |
11.1.c |
The ramp is inaccessible because the ends of the handrails are not rounded or returned, the handrails height is 32 inches, and the handrails lack 12 inch extensions at the top and bottom of the ramp. |
R4 |
24 months |
11.2 |
Exterior Entrance - East Entrance |
||
11.2.a |
The double doors are inaccessible because each leaf is 30 inches wide. |
D24 |
24 months |
11.3 |
Justice of the Peace Office |
||
11.3.a |
The entrance door is inaccessible because it requires 11 pounds of force to open. |
D2 |
24 months |
11.4 |
Justice of the Peace Court |
||
11.4.a |
The judge's bench and witness stand are inaccessible because they can be accessed only by steps. |
AA8 |
24 months |
11.4.b |
The entrance door is inaccessible because it has an opening width of 30 inches. |
D25 |
24 months |
11.4.c |
The entrance door is inaccessible because it requires 11 pounds of force to open. |
D2 |
24 months |
11.4.d |
The courtroom is inaccessible because the tables do not provide the required knee space. |
PD3 |
24 months |
11.5 |
Judge's Office |
||
11.5.a |
The entrance door is inaccessible because it has an opening width of 30.75 inches. |
D25 |
24 months |
11.6 |
Community Room Men's Toilet Room with Stalls |
||
11.6.a |
The entrance door is inaccessible because it requires 7 pounds of force to open. |
D2 |
24 months |
11.6.b |
The lavatory is inaccessible because it has twist-type hardware. |
TR10 |
24 months |
11.6.c |
The designated accessible toilet is inaccessible because its centerline is 19 inches from the side wall. |
ST17 |
24 months |
11.6.d |
The designated accessible toilet is inaccessible because the flush control is on the closed side. |
ST2 |
24 months |
11.6.e |
The toilet paper dispenser in the designated accessible stall is inaccessible because it is mounted 37.5 inches from the rear wall. |
ST19 |
24 months |
11.6.f |
The side grab bar at the designated accessible toilet is inaccessible because it is obstructed by the toilet paper dispenser. |
ST8 |
24 months |
11.6.g |
The stall door swings into the required clear floor space at the lavatory. |
TR6 |
24 months |
11.7 |
Community Room Women's Toilet Room with Stalls |
||
11.7.a |
The toilet seat cover dispenser is inaccessible because it is mounted 60 inches above the finished floor behind the toilet. |
TR4 |
24 months |
11.7.b |
The lavatory is inaccessible because it has twist-type hardware. |
TR10 |
24 months |
11.7.c |
The designated accessible toilet is inaccessible because its centerline is 16.5 inches from the side wall. |
ST17 |
24 months |
11.7.d |
The side grab bar at the designated accessible toilet is inaccessible because it is obstructed by the toilet paper dispenser. |
ST8 |
24 months |
12 |
Liberty City Community Building |
||
12.1 |
Accessible Route from parking lot to entrance |
||
12.1.a |
The route is inaccessible because there is uneven asphalt paving at the beginning of the sidewalk from the parking lot. |
AR1 |
24 months |
12.2 |
Exterior Entrances |
||
12.2.a |
The building does not have directional signage posted at inaccessible entrances and does not have the International Symbol of Accessibility posted at accessible entrances. |
D16 |
24 months |
12.3 |
Dining Area |
||
12.3.a |
The entry door is inaccessible because knob hardware is used. |
D1 |
24 months |
12.4 |
Women's Single-User Toilet Room |
||
12.4.a |
The toilet room sign is mounted on the door. |
TR17 |
24 months |
12.4.b |
The toilet is inaccessible because its centerline is 21 inches from the side wall. |
SU15 |
24 months |
12.4.c |
The toilet is inaccessible because the flush control is on the closed side. |
SU1 |
24 months |
12.4.d |
The toilet paper dispenser is inaccessible because it is mounted 41 inches from the rear wall. |
SU17 |
24 months |
12.5 |
Men's Single-User Toilet Room |
||
12.5.a |
The toilet room sign is mounted on the door. |
TR17 |
24 months |
12.5.b |
The toilet is inaccessible because its centerline is 17 inches from the side wall. |
SU15 |
24 months |
12.5.c |
The toilet paper dispenser is inaccessible because it is mounted 44 inches from the rear wall. |
SU17 |
24 months |
12.5.d |
The rear grab bar at the toilet is inaccessible because it is 24 inches long. |
SU3 |
24 months |
12.6 |
Meeting Room |
||
12.6.a |
The entry door is inaccessible because it requires 10 pounds of force to open. |
D2 |
24 months |
12.7 |
Auditorium |
||
12.7.a |
There is no accessible route connecting the wheelchair seating areas and the stage. |
AA1 |
24 months |
12.7.b |
The ramp leading from the entrance to the seating areas is inaccessible because it lacks handrails. |
R4 |
24 months |
13 |
Longview Eastman Road Building |
||
13.1 |
Parking |
||
13.1.a |
The parking reserved for persons with disabilities is inaccessible because the signs are mounted too low. |
P6 |
24 months |
13.1.b |
The parking reserved for persons with disabilities is inaccessible because it is not located on the shortest accessible route to the accessible facility entrance. |
P5 |
24 months |
13.2 |
Exterior Entrance |
||
13.2.a |
The door is inaccessible because knob hardware is used. |
D1 |
24 months |
13.3 |
Women's Single-User Toilet Room |
||
13.3.a |
The toilet room sign is mounted on the door. |
TR17 |
24 months |
13.3.b |
The door is inaccessible because it has an opening width of 31 inches. |
D25 |
24 months |
13.3.c |
The door is inaccessible because it requires 12 pounds of force to open. |
D2 |
24 months |
13.3.d |
No accessible mirror has been provided. |
TR14 |
24 months |
13.3.e |
The toilet is inaccessible because its centerline is 19 inches from the side wall. |
SU15 |
24 months |
13.3.f |
The side grab bar at the toilet is inaccessible because it is mounted with its farther end 48.5 inches from the rear wall. |
SU6 |
24 months |
13.3.g |
The rear grab bar at the toilet is inaccessible because it is 33 inches long. |
SU3 |
24 months |
13.4 |
Men's Single-User Toilet Room |
||
13.4.a |
The toilet room sign is mounted on the door. |
TR17 |
24 months |
13.4.b |
The door is inaccessible because it has an opening width of 31 inches. |
D25 |
24 months |
13.4.c |
The door is inaccessible because it requires 11 pounds of force to open. |
D2 |
24 months |
13.4.d |
No accessible mirror has been provided. |
TR14 |
24 months |
13.4.e |
The toilet is inaccessible because its centerline is 18.5 inches from the side wall. |
SU15 |
24 months |
13.4.f |
The side grab bar at the toilet is inaccessible because it is mounted with its farther end 48 inches from the rear wall. |
SU6 |
24 months |
13.4.g |
The rear grab bar at the toilet is inaccessible because it is 33 inches long. |
SU3 |
24 months |
13.4.h |
The toilet paper dispenser is inaccessible because it is mounted 48 inches from the rear wall and above the side grab bar. |
SU17 |
24 months |
13.5 |
Drinking fountain |
||
13.5.a |
The drinking fountain is inaccessible because it has a spout that is 38 inches above the finished floor. |
DF6 |
24 months |
13.5.b |
The drinking fountain is inaccessible because the flow of water is 1 inch high. |
DF7 |
24 months |
14 |
Olivia R. Hilburn Community Building |
||
14.1 |
Parking |
||
14.1.a |
The parking reserved for persons with disabilities is inaccessible because it lacks appropriate vertical signage. |
P6 |
24 months |
14.2 |
Exterior Entrance |
||
14.2.a |
The door is inaccessible because there is a slope of 6.6% at the top landing of the ramp which is within the door's required maneuvering clearance. |
D13 |
24 months |
14.2.b |
The entrance is inaccessible because the vestibule in between the glass storm door and the main entrance door is not sufficiently deep. |
D3 |
24 months |
14.3 |
Ramp at rear of building |
||
14.3.a |
The ramp is inaccessible because its top landing (within the exterior entrance door's required maneuvering clearance) is 6.6%. |
R3 |
24 months |
14.4 |
Women's Single-User Toilet Room |
||
14.4.a |
The pull side of the door, which is accessed through a front approach, is inaccessible because it has only 10 inches of clear space on the latch side. |
D6 |
24 months |
14.4.b |
The toilet paper dispenser is inaccessible because it is mounted 37 inches from the rear wall. |
SU17 |
|
14.4.c |
The rear grab bar at the toilet is inaccessible because it is 24 inches long. |
SU3 |
24 months |
14.5 |
Men's Single-User Toilet Room |
||
14.5.a |
The pull side of the door, which is accessed through a front approach, is inaccessible because it has only 10 inches of clear space on the latch side. |
D6 |
24 months |
14.5.b |
The toilet is inaccessible because the flush control is on the closed side. |
SU1 |
24 months |
14.5.c |
The toilet paper dispenser is inaccessible because it is mounted 42 inches from the rear wall. |
SU17 |
24 months |
14.5.d |
The rear grab bar at the toilet is inaccessible because it is 24 inches long. |
SU3 |
24 months |
15 |
Road and Bridge-Precinct 1-Commissioner's Office |
||
15.1 |
Parking |
||
15.1.a |
The parking lot, with a total of 6 parking spaces, is inaccessible because it has no spaces designated as accessible. This lot requires 1 van accessible space. |
P3 |
24 months |
15.2 |
Exterior Entrance |
||
15.2.a |
The pull side of the entrance door, which is accessed through a front approach, is inaccessible because a chair obstructs the clear space on the latch side. |
D6 |
24 months |
15.2.b |
The door is inaccessible because knob hardware is used. |
D1 |
24 months |
15.3 |
Unisex Single-User Toilet Room |
||
15.3.a |
The toilet room sign is mounted on the door and has no raised or Braille characters. |
TR17 |
24 months |
15.3.b |
The door is inaccessible because it has an opening width of only 30 inches. |
D25 |
24 months |
15.3.c |
The door is inaccessible because it requires 25 pounds of force to open. |
D2 |
24 months |
15.3.d |
No accessible mirror has been provided. |
TR14 |
24 months |
15.3.e |
The lavatory is inaccessible because it has twist-type hardware. |
TR10 |
24 months |
15.3.f |
The toilet is inaccessible because its centerline is 17 inches from the side wall. |
SU15 |
24 months |
15.3.g |
The toilet is inaccessible because the flush control is on the closed side. |
SU1 |
24 months |
15.3.h |
The rear grab bar at the toilet is inaccessible because its closer end is mounted 13 inches from the side wall. |
SU3 |
24 months |
16 |
Road and Bridge-Precinct 2-Commissioner's Office (Community Center and Tax Office Attached to Building) |
||
16.1 |
Overall Parking |
||
16.1.a |
The parking reserved for persons with disabilities is inaccessible because the access aisle is 74 inches wide. |
P8 |
24 months |
16.2 |
Ramps Leading to Justice of the Peace, Commissioner and Constable's Office |
||
16.2.a |
The upper ramp leading to the Commissioner Office is inaccessible because it has a cross-slope of up to 2.4%. |
R5 |
24 months |
16.2.b |
The upper ramps leading to the Commissioner Office and Constable's Office are inaccessible because they lack handrails on one side of the ramp and handrail extensions at the top of the ramps. |
R4 |
24 months |
16.3 |
Justice of the Peace Office |
||
16.3.a |
The jury box is inaccessible because it can be accessible only by steps, and the route narrows to a width of 21 inches. |
AA8 |
24 months |
16.3.b |
The witness stand is inaccessible because it can be accessible only by steps, and the route narrows to a width of 28 inches. |
AA8 |
24 months |
16.4 |
Justice of the Peace Office Courtroom single-user toilet room |
||
16.4.a |
The toilet is inaccessible because the flush control is on the closed side. |
SU1 |
24 months |
16.4.b |
The side grab bar at the toilet is inaccessible because it is mounted with its farther end 47 inches from the rear wall. |
SU6 |
24 months |
16.4.c |
The rear grab bar at the toilet is inaccessible because it is 24 inches long and mounted with its farther end 30 inches from the side wall. |
SU3 |
24 months |
16.5 |
Tax Office - Parking |
||
16.5.a |
The parking reserved for persons with disabilities is inaccessible because the access aisle is 64 inches wide. |
P8 |
24 months |
16.6 |
Tax Office - Exterior Entrance |
||
16.6.a |
The door is inaccessible because it has an opening width of only 30 inches. |
D25 |
24 months |
16.6.b |
The door is inaccessible because there is a 1 inch high threshold. |
D23 |
24 months |
16.7 |
Tax Office - Interior Ramp |
||
16.7.a |
The ramp is inaccessible because it slopes up to 13.4%, and the top landing is not level. |
R5 |
24 months |
16.7.b |
The ramp is inaccessible because it lacks handrails on one side. |
R4 |
24 months |
16.7.c |
The ramp is inaccessible because it does not have edge protection at the drop off sides. |
R1 |
24 months |
16.8 |
Community Center (Polling Also) Telephone |
||
16.8.a |
The telephone is inaccessible because its clear floor space is 10 inches wide, and it lacks volume control. |
TT1 |
24 months |
16.9 |
Community Center Coat Rack |
||
16.9.a |
The coat rack is inaccessible because it is mounted with the rack 68 inches above the finished floor. |
TR5 |
24 months |
16.1 |
Community Center Exterior Ramp |
||
16.10.a |
The ramp is inaccessible because it lacks handrails. |
R4 |
24 months |
16.10.b |
The ramp is inaccessible because it does not have edge protection at the drop off sides. |
R1 |
24 months |
16.11 |
Community Center Interior Ramp leading to Unisex Single-User Toilet Room |
||
16.11.a |
The ramp is inaccessible because it slopes up to 10.8%. |
R5 |
24 months |
16.11.b |
The ramp is inaccessible because it lacks handrails. |
R4 |
24 months |
16.12 |
Community Center Unisex Single-User Toilet Room |
||
16.12.a |
The entry door is inaccessible because there is a slope of 10.8 within the door's required maneuvering clearance due to an interior ramp. |
D13 |
24 months |
16.12.b |
The toilet room sign is mounted with its centerline at 64 inches above the floor. |
TR17 |
24 months |
16.12.c |
The soap dispenser is inaccessible because it is mounted with the controls 49 inches above the finished floor with forward reach required. |
TR5 |
24 months |
16.12.d |
The toilet is inaccessible because its centerline is 19.5 inches from the side wall. |
SU15 |
24 months |
16.12.e |
The toilet is inaccessible because the flush control is on the closed side. |
SU1 |
24 months |
16.12.f |
The toilet paper dispenser is inaccessible because it is mounted 39 inches from the rear wall. |
SU17 |
24 months |
16.12.g |
The side grab bar at the toilet is inaccessible because it is mounted with its farther end 48 inches from the rear wall. |
SU6 |
24 months |
16.13 |
Kitchen |
||
16.13.a |
The route to the kitchen is inaccessible because there are several steps leading to the kitchen. |
AR2 |
24 months |
17 |
Road and Bridge-Precinct 3-Commissioner's Office |
||
17.1 |
Parking |
||
17.1.a |
The parking lot, with a total of 6 parking spaces, is inaccessible because it lacks a van-accessible parking space. This lot requires 1 van accessible space. |
P3 |
24 months |
17.1.b |
The parking reserved for persons with disabilities is inaccessible because it slopes 2.4%. |
P7 |
24 months |
17.2 |
Exterior Route |
||
17.2.a |
The route from the parking lot to the entrance is inaccessible because there is a 7.1% slope and a 2.1% cross-slope at one point along the route. |
AR1 |
24 months |
17.3 |
Exterior Entrance |
||
17.3.a |
The door is inaccessible because there is a 1 inch high threshold. |
D23 |
24 months |
17.3.b |
The door is inaccessible because knob hardware is used. |
D1 |
24 months |
17.4 |
Women's Toilet Room with Stalls |
||
17.4.a |
The toilet room contains a number of inaccessible elements and is not accessible to people with disabilities. |
ST14 |
24 months |
17.5 |
Men's Toilet Room with Stalls |
||
17.5.a |
The toilet room contains a number of inaccessible elements and is not accessible to people with disabilities. |
ST14 |
24 months |
18 |
Road and Bridge-Precinct 4-Commissioner's Office |
||
18.1 |
Parking |
||
18.1.a |
The parking lot, with a total of 15 parking spaces, is inaccessible because there is no van-accessible parking space, and the designated accessible spaces slope 3.2% - 3.6% and do not have clear pavement markings. This lot requires 1 van accessible space. |
P3 |
24 months |
18.1.b |
The route from the parking lot to the entrance is inaccessible because there is a slope of 5.5% in front of the exterior entrance. |
AR1 |
24 months |
18.2 |
Exterior Entrance |
||
18.2.a |
The exterior entrance door is inaccessible because there is a slope of 5.5% within the door's required maneuvering clearance. |
D13 |
24 months |
18.2.b |
The entrance doors (exterior and interior) are inaccessible because knob hardware is used. |
D1 |
24 months |
18.2.c |
The entrance is inaccessible because there is a 1 inch high threshold. |
D23 |
24 months |
18.3 |
Lobby |
||
18.3.a |
The entry door is inaccessible because knob hardware is used. |
D1 |
24 months |
18.4 |
Commissioner's Office |
||
18.4.a |
The entry door is inaccessible because knob hardware is used. |
D1 |
24 months |
18.5 |
Unisex Single-User Toilet Room |
||
18.5.a |
The toilet room contains a number of inaccessible elements and is not accessible to people with disabilities. |
ST14 |
24 months |
19 |
Service Center Building |
||
19.1 |
Parking |
||
19.1.a |
The parking lot, with a total of 12 parking spaces, is inaccessible because there is no van-accessible parking space, the designated accessible spaces and access aisles slope 2.6% with a cross-slope of 3.7%. This lot requires 1 van accessible space. |
P3 |
24 months |
19.2 |
Exterior Ramp |
||
19.2.a |
The route is inaccessible because there is a 1 inch lip at the bottom edge of the ramp. |
AR1 |
24 months |
19.2.b |
The ramp is inaccessible because it does not have edge protection at the drop off sides. |
R1 |
24 months |
19.2.c |
The ramp is inaccessible because it lacks level landings at the top and bottom. |
R5 |
24 months |
19.2.d |
The ramp is inaccessible because it lacks a handrail on one side, the ends of the handrail are not rounded or returned, and the handrail is mounted at 32.5 inches height. |
R4 |
24 months |
19.3 |
Exterior Entrance |
||
19.3.a |
The building does not have directional signage posted at inaccessible entrances and does not have the International Symbol of Accessibility posted at accessible entrances. |
D16 |
24 months |
19.4 |
Interior doors throughout facility |
||
19.4.a |
The doors are inaccessible because knob hardware is used. |
D1 |
24 months |
19.5 |
Women's Toilet Room with Stalls |
||
19.5.a |
The toilet room sign is mounted on the door and has no raised or Braille characters. |
TR17 |
24 months |
19.5.b |
The door is inaccessible because it has an opening width of only 29.5 inches. |
D25 |
24 months |
19.5.c |
The door is inaccessible because it requires 12 pounds of force to open. |
D2 |
24 months |
19.5.d |
The pull side of the door, which is accessed through a front approach, is inaccessible because it has only 2 inches of clear space on the latch side. |
D6 |
24 months |
19.5.e |
The push side of the door, which is accessed through a front approach and which has both a closer and a latch, is inaccessible because it has only 2 inches of clear space on the latch side. |
D7 |
24 months |
19.5.f |
The light switch dispenser is inaccessible because it is mounted with the controls 55 inches above the finished floor. |
TR5 |
24 months |
19.5.g |
The seat cover dispenser is inaccessible because it is mounted with the controls 53 inches above the finished floor. |
TR5 |
24 months |
19.5.h |
The towel dispenser is inaccessible because it is mounted with the controls 56 inches above the finished floor. |
TR5 |
24 months |
19.5.i |
The lavatory is inaccessible because the top of the rim or counter is 29 inches above the finished floor, bottom of the apron is 26.5 inches above the finished floor, and its knee / toe clearances do not comply. |
TR11 |
24 months |
19.5.j |
The lavatory is inaccessible because it has twist-type hardware. |
TR10 |
24 months |
19.5.k |
The designated accessible toilet is inaccessible because its centerline is 17.5 inches from the side wall. |
ST17 |
24 months |
19.5.l |
No accessible coat hook has been provided. TR1 |
||
19.5.m |
The side grab bar at the designated accessible toilet is inaccessible because it is 39 inches long and it is mounted with its farther end 42 inches from the rear wall. |
ST7 |
24 months |
19.5.n |
The side grab bar at the designated accessible toilet is inaccessible because it is obstructed by the toilet paper dispenser. |
ST9 |
24 months |
19.5.o |
The rear grab bar at the designated accessible toilet is inaccessible because it is 19 inches long. |
ST4 |
24 months |
19.5.p |
The designated accessible toilet is inaccessible because the rear grab bar is obstructed by the flush valve. |
ST5 |
24 months |
19.5.q |
The stall door is inaccessible because twist hardware is used. |
D1 |
24 months |
19.6 |
Men's Toilet Room with Stalls |
||
19.6.a |
The toilet room sign is mounted on the door and has no raised or Braille characters. |
TR17 |
24 months |
19.6.b |
The door is inaccessible because it has an opening width of only 29 inches. |
D25 |
24 months |
19.6.c |
The door is inaccessible because it requires 12 pounds of force to open. |
D2 |
24 months |
19.6.d |
The pull side of the door, which is accessed through a front approach, is inaccessible because it has only 2 inches of clear space on the latch side. |
D6 |
24 months |
19.6.e |
The push side of the door, which is accessed through a front approach and which has both a closer and a latch, is inaccessible because it has only 2 inches of clear space on the latch side. |
D7 |
24 months |
19.6.f |
The light switch dispenser is inaccessible because it is mounted with the controls 54 inches above the finished floor. |
TR5 |
24 months |
19.6.g |
The towel dispenser is inaccessible because it is mounted with the controls 55 inches above the finished floor. |
TR5 |
24 months |
19.6.h |
The lavatory is inaccessible because the top of the rim or counter is 29 inches above the finished floor, the bottom of the apron is 26.5 inches above the finished floor, and its knee / toe clearances do not comply. |
TR11 |
24 months |
19.6.i |
The lavatory is inaccessible because it has twist-type hardware. |
TR10 |
24 months |
19.6.j |
The urinal is inaccessible because the rim is 21.5 inches above the finished floor. |
TR20 |
24 months |
19.6.k |
The designated accessible toilet is inaccessible because the top of the seat is 19.5 inches above the finished floor. |
ST20 |
24 months |
19.6.l |
No accessible coat hook has been provided. |
TR1 |
24 months |
19.6.m |
The side grab bar at the designated accessible toilet is inaccessible because it is 39 inches long and it is mounted with its farther end 42 inches from the rear wall. |
ST7 |
24 months |
19.6.n |
The side grab bar at the designated accessible toilet is inaccessible because it is obstructed by the toilet paper dispenser. |
ST9 |
24 months |
19.6.o |
The rear grab bar at the designated accessible toilet is inaccessible because it is 19 inches long. |
ST4 |
24 months |
19.6.p |
The designated accessible toilet is inaccessible because the rear grab bar is obstructed by the flush valve. |
ST5 |
24 months |
19.6.q |
The stall door is inaccessible because twist hardware is used. |
D1 |
24 months |
19.7 |
Drinking Fountain Near Room 103 |
||
19.7.a |
The drinking fountain is inaccessible because it has a spout that is 37 inches above the finished floor. |
DF6 |
24 months |
19.8 |
Community Room - Hallway entrance |
||
19.8.a |
The door is inaccessible because it has an opening width of only 28.5 inches. |
D25 |
24 months |
20 |
Community Room - Room entrance |
||
20.1 |
The door is inaccessible because it has an opening width of only 27 inches. |
D25 |
24 months |
20.2 |
The door is inaccessible because it requires 9 pounds of force to open. |
D2 |
24 months |
21 |
Community Room - Kitchen |
||
21.1 |
The door is inaccessible because it has an opening width of only 28.5 inches. |
D25 |
24 months |
22 |
Community Room - Stage |
||
22.1 |
There is no accessible route connecting the wheelchair seating areas and the stage. |
AA1 |
24 months |
23 |
South Street Community Center (Polling Only) |
||
23.1 |
Parking |
||
23.1.a |
The parking lot is inaccessible because spaces and access aisles are not marked. This lot requires 1 van accessible space and 1 standard space. |
P3 |
24 months |
24 |
Youth Detention Center |
||
24.1 |
Parking |
||
24.1.a |
The parking lot, with a total of 75 parking spaces, is inaccessible because it has 3 spaces designated as accessible but none are designated as van-accessible. This lot requires 1 van accessible space and 2 standard spaces. |
P3 |
24 months |
24.1.b |
The parking reserved for persons with disabilities is inaccessible because the signs are mounted too low. |
P6 |
24 months |
24.1.c |
The parking reserved for persons with disabilities is inaccessible because the pavement marking is not clear. |
P7 |
24 months |
24.2 |
Accessible Route from curb ramp to front entrance |
||
24.2.a |
The route is inaccessible because it has a slope of at least 9.6%. |
AR1 |
24 months |
24.3 |
Juvenile Detention - Lobby |
||
24.3.a |
The interior door is inaccessible because it requires 7 pounds of force to open. |
D2 |
24 months |
24.3.b |
The interior door is inaccessible because knob hardware is used. |
D1 |
24 months |
24.3.c |
The interior room signage provided throughout the facility is inaccessible because it does not have raised and Braille characters. |
D26 |
24 months |
24.4 |
Juvenile Detention - Intake Office |
||
24.4.a |
The door is inaccessible because it requires 7 pounds of force to open. |
D2 |
24 months |
24.5 |
Juvenile Detention - Attorney Counseling Office |
||
24.5.a |
The doors are inaccessible because knob hardware is used. |
D1 |
24 months |
24.6 |
Juvenile Detention - Cells |
||
24.6.a |
There is no accessible cell provided. |
PJ1 |
24 months |
24.7 |
Juvenile Detention - Classroom B |
||
24.7.a |
The door is inaccessible because it requires 9 pounds of force to open. |
D2 |
24 months |
24.8 |
Juvenile Detention - Unisex Locker Room |
||
24.8.a |
There is no signage. |
TR17 |
24 months |
24.8.b |
The door is inaccessible because it requires 11 pounds of force to open. |
D2 |
24 months |
24.8.c |
No accessible mirror has been provided. |
TR14 |
24 months |
24.8.d |
The toilet is inaccessible because the top of the seat is 20 inches above the finished floor. |
SU18 |
24 months |
24.8.e |
The toilet is inaccessible because its centerline is 19.5 inches from the side wall. |
SU15 |
24 months |
24.8.f |
The side grab bar at the toilet is inaccessible because it is 24 inches long and it is mounted with its farther end 26 inches from the rear wall. |
SU6 |
24 months |
24.8.g |
There is no accessible shower provided. |
B8 |
24 months |
24.9 |
Women's Single-User Toilet Room Near Lobby |
||
24.9.a |
The signage is inaccessible. |
TR17 |
24 months |
24.9.b |
The door is inaccessible because it requires 6 pounds of force to open. |
D2 |
24 months |
24.9.c |
The door is inaccessible because knob hardware is used. |
D1 |
24 months |
24.9.d |
The push side of the door, which is accessed from the latch side of the door, is inaccessible because it has only 9 inches of clear space on the latch side. |
D11 |
24 months |
24.9.e |
The lavatory is inaccessible because the top of the counter is 36 inches above the finished floor. |
TR11 |
24 months |
24.9.f |
The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact. |
TR12 |
24 months |
24.9.g |
The toilet is inaccessible because its centerline is 19.5 inches from the side wall. |
SU15 |
24 months |
24.1 |
Men's Single-User Toilet Room Near Lobby |
||
24.10.a |
The signage is inaccessible. |
TR17 |
24 months |
24.10.b |
The door is inaccessible because it requires 6 pounds of force to open. |
D2 |
24 months |
24.10.c |
The door is inaccessible because knob hardware is used. |
D1 |
24 months |
24.10.d |
The lavatory is inaccessible because the top of the counter is 36 inches above the finished floor. |
TR11 |
24 months |
24.10.e |
The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact. |
TR12 |
24 months |
24.10.f |
The toilet is inaccessible because its centerline is 19.5 inches from the side wall. |
SU15 |
24 months |
24.10.g |
The side grab bar at the toilet is inaccessible because it is obstructed by the toilet seat cover dispenser. SU8 |
||
24.11 |
Probation Center - Entrance |
||
24.11.a |
The interior door is inaccessible because it requires 13 pounds of force to open. |
D2 |
24 months |
24.12 |
Probation Center - Men's Toilet Room with Stalls |
||
24.12.a |
The signage is inaccessible. |
TR17 |
24 months |
24.12.b |
The door is inaccessible because it requires 11 pounds of force to open. |
D2 |
|
24.12.c |
Although an audible alarm is provided in this facility, there is no visual alarm appliance in the toilet room. |
TR21 |
24 months |
24.12.d |
No accessible mirror has been provided. |
TR14 |
24 months |
24.12.e |
The lavatory is inaccessible because the top of the counter is 35.25 inches above the finished floor. |
TR11 |
24 months |
24.12.f |
The lavatory is inaccessible because it has inadequate clear floor space. |
TR8 |
24 months |
24.12.g |
The lavatory is inaccessible because it has twist-type hardware. |
TR10 |
24 months |
24.12.h |
The urinal is inaccessible because the rim is 19 inches above the finished floor, the flush control height is 47 inches, and the clear floor space width is 26.5 inches. |
TR20 |
24 months |
24.12.i |
The designated accessible stall is incorrectly configured as an ambulatory stall, and there is no standard accessible stall provided. |
ST15 |
24 months |
24.13 |
Probation Center - Women's Toilet Room with Stalls |
||
24.13.a |
The signage is inaccessible. |
TR17 |
24 months |
24.13.b |
The door is inaccessible because it requires more than 5 pounds of force to open. |
D2 |
24 months |
24.13.c |
Although an audible alarm is provided in this facility, there is no visual alarm appliance in the toilet room. |
TR21 |
24 months |
24.13.d |
The seat cover dispenser is inaccessible because it is mounted with the controls 58 inches above the finished floor. |
TR5 |
24 months |
24.13.e |
The paper towel dispenser is inaccessible because it is mounted 49 inches above the finished floor behind the counter. |
TR4 |
24 months |
24.13.f |
The lavatory is inaccessible because the top of the counter is 36.25 inches above the finished floor. |
TR11 |
24 months |
24.13.g |
The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact. |
TR12 |
24 months |
24.13.h |
The stall door is inaccessible because twisting is required. |
D1 |
24 months |
24.13.i |
The designated accessible stall is incorrectly configured as an ambulatory stall, and there is no standard accessible stall provided. |
ST15 |
24 months |
24.14 |
Probation Center - Waiting Room |
||
24.14.a |
The door is inaccessible because knob hardware is used. |
D1 |
24 months |
24.15 |
Probation Center - Interview Room |
||
24.15.a |
The doors are inaccessible because knob hardware is used. |
D1 |
24 months |
24.16 |
Probation Center - Conference Room |
||
24.16.a |
The door is inaccessible because knob hardware is used. |
D1 |
24 months
|