ATTACHMENT K: Program Access in Existing Facilities
Please Note: Paragraph 45 of the Settlement Agreement requires that within three months of the effective date of this Agreement, the City provide signage as necessary to comply with 28 C.F.R. § 35.163(b), after having surveyed all facilities that are the subject of this Agreement for the purpose of identifying those that have multiple entrances not all of which are accessible.
In order to ensure that each of the City's programs, services, and activities operating at a facility that is the subject of this Agreement, when viewed in its entirety, is readily accessible to and usable by persons with disabilities, the City will take the actions referenced by the alphanumeric code and described in detail in attachment M to this Settlement Agreement.
|
|||
Item # |
Access Issue |
Required Action |
Completion Date |
---|---|---|---|
1. |
The City will correct the following access issues at the Gadsden Amphitheater, located at 90 Walnut Street: |
|
|
1.1 |
Parking |
|
|
1.1a |
Lot 1, with a total of 51 parking spaces, is inaccessible because it does not have parking spaces reserved for persons with disabilities with the required access aisles; many of the areas that could serve as access aisles are not paved or level. This lot requires 1 van accessible space and 2 standard spaces. |
P3 |
24 months |
1.1b |
Lot 2, with a total of 211 parking spaces, is inaccessible because it has an inadequate number of spaces reserved for persons with disabilities and lacks appropriate signage. This lot requires 1 van accessible space and 6 standard spaces. |
P3 |
24 months |
1.1c |
Lot 3, with a total of 164 parking spaces, is inaccessible because it has an inadequate number of spaces reserved for persons with disabilities, and parking spaces that are reserved for persons with disabilities lack access aisles and appropriate signage. This lot requires 1 van accessible space and 5 standard spaces. |
P3 |
24 months |
1.2 |
Accessible Routes |
||
1.2a |
The routes from the locations in the parking lots where accessible parking must be installed to the amphitheater entrances are inaccessible because the surface is not level, firm, stable, or slip resistant. |
AR1 |
24 months |
1.2b |
The route from the Parks and Recreation office to the amphitheater entrance is inaccessible because the surface is not level, firm, stable, or slip resistant. |
AR1 |
24 months |
1.2c |
There is no access from the ground entrance to the amphitheater for people with mobility disabilities due to the presence of steps. |
D16 |
24 months |
1.2d |
There is no accessible route connecting the wheelchair seating areas and the stage. |
AA1 |
24 months |
2. |
The City will correct the following items at City Hall, located at 90 Broad Street: |
|
|
2.1 |
Parking |
|
|
2.1a |
The parking lot is inaccessible because there are no access aisles for the parking spaces reserved for persons with disabilities. |
P1 |
24 months |
2.1b |
The van accessible parking reserved for persons with disabilities is inaccessible because it lacks appropriate signage. |
P6 |
24 months |
2.2 |
Accessible Routes |
|
|
2.2a |
The curb ramp in front of the building is inaccessible because it has a slope of 11.1% and a lip of ½ inch. |
AR5 |
24 months
|
2.2b |
No accessible route is provided to the rear entrance. |
D16 |
24 months |
2.2c |
Many office doors throughout City Hall are inaccessible because knob hardware is used. |
D1 |
24 months |
2.3 |
Drinking Fountains – Municipal Court Office (left side fountain) |
|
|
2.3a |
The drinking fountain is inaccessible because it has a spout that is 40 inches above the finished floor. |
DF6 |
24 months |
2.3b |
The drinking fountain protrudes into the walkway and is not detectable to blind persons using a cane. |
AR8 |
24 months |
2.4 |
Women's Toilet Room – with stalls, ground floor |
|
|
2.4a |
The signage provided is inaccessible because it is mounted so that the centerline is 53 inches above the finished floor, and it does not have raised and Braille characters. |
TR17 |
24 months |
2.4b |
The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact. |
TR12 |
24 months |
2.4c |
There is no accessible stall provided. |
ST15 |
24 months |
2.5 |
Men's Toilet Room – single user, ground floor |
|
|
2.5a |
The signage provided is inaccessible because it is mounted so that the centerline is 53 inches above the finished floor, and it does not have raised and Braille characters. |
TR17 |
24 months
|
2.5b |
The door is inaccessible because knob hardware is used. |
D1 |
24 months |
2.5c |
The toilet's flush control is inaccessible because it is mounted at 48 inches above the finished floor. |
ST2 |
24 months |
2.5d |
The side grab bar at the toilet is inaccessible because it is obstructed by the toilet paper dispenser. |
SU7 |
24 months |
2.6 |
Elevator |
|
|
2.6a |
The elevator is inaccessible because the space between the car platform sill and the hoistway landing edge is 2 inches. |
E10 |
24 months |
2.7 |
Public Hearing Room/Pre-Council Meeting Room/Room 305 |
|
|
2.7a |
The room containing 20 seats is inaccessible because no wheelchair seating areas are provided. One wheelchair seating area is required. |
AA6 |
24 months |
2.7b |
The room is inaccessible to people who are hard of hearing because there is no assistive listening system provided. |
AA5 |
24 months |
2.8 |
City Council/Municipal Court |
|
|
2.8a |
There is no accessible route to the raised seating area for Council members because there is a 7 inch step to each of the two levels. |
AA1
|
24 months |
2.8b |
The room is inaccessible to people who are hard of hearing because there is no assistive listening system provided. |
AA5 |
24 months |
2.9 |
City Clerk's Office |
|
|
2.9a |
The counter is inaccessible because its top surface is 42 inches above the finished floor. |
C6 |
24 months |
3. |
The City will correct the following items at Convention Hall, located at 340 South 4th Street: |
|
|
3.1 |
Drinking Fountains – Near Men's and Women's Toilet Rooms |
|
|
3.1a |
The drinking fountains are inaccessible because they have spouts that are 43 inches (near women's toilet room) and 42 inches above the finished floor (Near men's toilet room). |
DF6 |
24 months |
3.2 |
Nan Calla Auditorium |
|
|
3.2a |
There is no accessible route connecting the wheelchair seating areas and the stage. |
AA1 |
24 months |
3.2b |
The room is inaccessible to people who are hard of hearing because there is no assistive listening system provided. |
AA5 |
24 months |
3.3 |
Women's Toilet Room – with stalls, near the assembly area |
|
|
3.3a |
The table in the hallway just outside the toilet room narrows the route to 28 inches wide. |
AR3 |
24 months |
3.3b |
The toilet room sign is mounted on the door and has no raised or Braille characters. |
TR18 |
24 months |
3.3c |
The door is inaccessible because it requires 10 pounds of force to open. |
D2 |
24 months |
3.3d |
The lavatories protrude into the walkway and are not detectable to blind persons using a cane. |
AR8 |
24 months |
3.3e |
The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact. |
TR12 |
24 months |
3.3f |
There is no accessible stall provided. |
ST15 |
24 months |
3.3g |
The ambulatory stall is inaccessible. |
ST1 |
24 months |
3.4 |
Men's Toilet Room – with stalls, near the assembly area |
|
|
3.4a |
The toilet room sign is mounted on the door and has no raised or Braille characters. |
TR18 |
24 months |
3.4b |
The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact. |
TR12 |
24 months |
3.4c |
The lavatory is inaccessible because the controls require twisting of the wrist to operate. |
TR3 |
24 months |
3.4d |
The urinal is inaccessible because the rim is more than 17 inches above the finished floor. |
TR20 |
24 months |
3.5 |
Men's Toilet Room – single user |
|
|
3.5a |
The toilet room sign is mounted on the door and has no raised or Braille characters. |
TR18 |
24 months |
3.5b |
The push side of the door, which is accessed through a front approach and which has both a closer and a latch, is inaccessible because it has only 8 inches of clear space on the latch side. |
D7 |
24 months |
3.5c |
The toilet is inaccessible because its centerline is 20 ½ inches from the side wall. |
SU15 |
24 months |
3.5d |
The rear grab bar at the toilet is inaccessible because it is mounted 8 inches from the side wall. |
SU3 |
24 months |
3.6 |
Arthur Green Room |
|
|
3.6a |
The room is inaccessible to people who are hard of hearing because there is no assistive listening system provided. |
AA5 |
24 months |
3.7 |
Women's Toilet Room – with stalls, near Arthur Green Room |
|
|
3.7a |
The toilet room sign is inaccessible because it is mounted on the door. |
TR18 |
24 months |
3.7b |
The door is inaccessible because it requires 10 pounds of force to open. |
D2 |
24 months |
3.7c |
The soap dispenser is inaccessible because it is mounted 53 inches above the finished floor over the lavatory. |
TR4 |
24 months |
3.7d |
The rear grab bar at the toilet is inaccessible because it is obstructed by the toilet sanitizer. |
SU4 |
24 months |
3.7e |
No accessible coat hook has been provided. |
TR1 |
24 months |
3.7f |
The toilet paper dispenser is inaccessible because it is mounted 44 inches from the rear wall. |
SU17 |
24 months |
3.8 |
Men's Toilet Room – with stalls, near Arthur Green Room |
|
|
3.8a |
The toilet room sign is mounted on the door. |
TR18 |
24 months |
3.8b |
The door is inaccessible because it requires 8 pounds of force to open. |
D2 |
24 months |
3.8c |
The soap dispenser is inaccessible because it is mounted 51 inches above the finished floor over the lavatory. |
TR4 |
24 months |
3.8d |
The urinal is inaccessible because the rim is 22 inches above the finished floor. |
TR20 |
24 months |
3.8e |
The toilet is inaccessible because there is insufficient clear floor space provided. |
SU16 |
24 months |
3.8f |
The toilet is inaccessible because its centerline is 19 inches from the side wall. |
SU15 |
24 months |
3.8g |
No accessible coat hook has been provided. |
TR1 |
24 months |
3.8h |
The side grab bar at the toilet is inaccessible because it is mounted 13 ½ inches from the rear wall. |
SU6 |
24 months |
3.8i |
The rear grab bar at the toilet is inaccessible because it is obstructed by the sanitizer. |
SU4 |
24 months |
4. |
The City will correct the following items at East Gadsden Community Center, located at 921 Wilson Avenue: |
|
|
4.1 |
Parking |
|
|
4.1a |
The parking lot is inaccessible because it has no van accessible space, there are no access aisles, and the parking reserved for people with disabilities lacks appropriate vertical signage. This lot requires one van accessible space. |
P3 |
24 months |
4.2 |
Entrances |
|
|
4.2a |
The building does not have directional signage posted at inaccessible entrances and does not have the International Symbol of Accessibility posted at accessible entrances. |
D16 |
24 months |
4.2b |
The door is inaccessible because the vestibule is not sufficiently deep. |
D3 |
24 months |
4.3 |
Interior Signage |
|
|
4.3a |
The signage provided is inaccessible because it is mounted on the door and does not have raised and Braille characters. |
D26 |
24 months |
4.4 |
Drinking Fountain – near gym |
|
|
4.4a |
The drinking fountain is inaccessible because it has a spout that is 43 inches above the finished floor and its controls require twisting and grasping as well as more than 5 pounds of force to operate. |
DF6 DF2 |
24 months |
4.5 |
Women's Toilet and Shower Room – with stalls |
|
|
4.5a |
No accessible mirror has been provided. |
TR14 |
24 months |
4.5b |
The paper towel dispenser is inaccessible because it is mounted with the controls 65 3/4 inches above the finished floor. |
TR5 |
24 months |
4.5c |
The lavatory is inaccessible because the bottom edge of the apron is 27 inches above the finished floor. |
TR11 |
24 months |
4.5d |
The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact. |
TR12 |
24 months |
4.5e |
The lavatory is inaccessible because it has twist-type hardware. |
TR10 |
24 months |
4.5f |
The toilet is inaccessible because it has insufficient clear floor space. |
ST18 |
24 months |
4.5g |
The designated accessible toilet is inaccessible because its centerline is 16 ½ inches from the side wall. |
ST17 |
24 months |
4.5h |
The designated accessible toilet is inaccessible because the flush control is on the closed side. |
ST2 |
24 months |
4.5i |
The side grab bar at the designated accessible toilet is inaccessible because it is 24 inches long and it is mounted 33 inches from the rear wall. |
ST7 |
24 months |
4.5j |
There is no rear grab bar provided at the designated accessible toilet. |
ST3 |
24 months |
4.5k |
The paper towel dispenser in the shower area protrudes into the walkway and is not detectable to blind persons using a cane. |
AR8 |
24 months |
4.5l |
There is no accessible shower provided. |
B8 |
24 months |
4.6 |
Men's Toilet, Locker and Shower Room – with stalls |
|
|
4.6a |
The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact. |
TR12 |
24 months
|
4.6b |
The lavatory is inaccessible because it has twist-type hardware. |
TR10 |
24 months |
4.6c |
The paper towel dispenser in the toilet area protrudes into the walkway and is not detectable to blind persons using a cane. |
AR8 |
24 months
|
4.6d |
The urinal is inaccessible because the rim is 21 inches above the finished floor and the flush control is 49 inches above the finished floor. |
TR20 |
24 months |
4.6e |
There is no accessible stall provided. |
ST15 |
24 months |
4.6f |
There is no accessible locker provided. |
LR3 |
24 months |
4.6g |
There is no accessible shower provided. |
B8 |
24 months |
4.6h |
No accessible towel hook has been provided. |
TR5 |
24 months |
4.7 |
Gym |
|
|
4.7a |
There is no accessible route connecting the wheelchair seating areas and the stage. |
AA1 |
24 months |
4.8 |
Pool Table Room |
|
|
4.8a |
There is no access to the room for people with mobility disabilities because of stairs. |
AR9 |
24 months |
4.9 |
Library |
|
|
4.9a |
The check-out counter is inaccessible because its top surface is 42 inches above the finished floor. |
C6 |
24 months |
4.9b |
The book stacks are inaccessible because the space between stacks is only 33 ½ inches wide. |
AR3 |
24 months |
5 |
The City will correct the following items at Elliott Community Center, located at 2829 W. Meighan Boulevard: |
|
|
5.1 |
Parking |
|
|
5.1a |
The parking lot, with a total of 85 parking spaces, is inaccessible because it only has 2 spaces reserved for people with disabilities, and those spaces have no access aisles. This lot requires one van accessible space and three standard spaces. |
P1
|
24 months |
5.2 |
Accessible Route |
|
|
5.2a |
The ramp is inaccessible because the handrails are 17 and 31 inches above the ramp surface on the left and right, respectively, handrail extensions are not provided on both sides, and the ramp does not have edge protection at the drop-off sides. |
R1; R4 |
24 months |
5.2b |
The interior signage provided is inaccessible because the room number signs do not have raised and Braille characters. |
D26 |
24 months |
5.3 |
Drinking Fountains |
|
|
5.3a |
The drinking fountain in the kitchen is inaccessible because its spout is 38 ½ inches above the finished floor. |
DF6 |
24 months |
5.3b |
The drinking fountain in the library is inaccessible because its spout is 43 inches above the finished floor and lacks the required knee clearance. |
DF5; DF6 |
24 months |
5.4 |
Auditorium |
|
|
5.4a |
There is no accessible route connecting the wheelchair seating areas and the stage. |
AA1 |
24 months |
5.4b |
The auditorium containing 342 seats is inaccessible because the wheelchair seating locations lack fixed companion seats. |
AA6 |
24 months
|
5.4c |
The auditorium is inaccessible to people who are hard of hearing because no assistive listening system is provided. This auditorium requires 14 receivers. |
AA4 |
24 months
|
5.5 |
Women's Toilet Room – with stalls |
|
|
5.5a |
The signage provided is inaccessible because it is not mounted on the latch side of the door and it lacks raised and Braille characters. |
TR17 |
24 months |
5.5b |
The route into the toilet room is inaccessible because the heating element mounted in the doorway reduces the vertical clearance to 77 inches. |
AR7
|
24 months |
5.5c |
No accessible mirror has been provided. |
TR14 |
24 months |
5.5d |
The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact. |
TR12 |
24 months |
5.5e |
No accessible stall has been provided. |
ST15 |
24 months |
5.6 |
Men's Toilet Room – with stalls |
|
|
5.6a |
The signage provided is inaccessible because it is not mounted on the latch side of the door and it lacks raised and Braille characters. |
TR17 |
24 months
|
5.6b |
The door is inaccessible because it requires more than 5 pounds of force to open. |
D2 |
24 months |
5.6c |
The route into the toilet room is inaccessible because the heating element mounted in the doorway reduces vertical clearance to 77 inches. |
AR7
|
24 months |
5.6d |
The light switch is inaccessible because it is mounted with the controls 65 inches above the finished floor. |
TR5 |
24 months |
5.6e |
No accessible mirror has been provided. |
TR14 |
24 months |
5.6f |
The paper towel dispenser is inaccessible because it is mounted with the controls 58 ½ inches above the finished floor. |
TR5 |
24 months |
5.6g |
The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact. |
TR12 |
24 months |
5.6h |
The lavatory is inaccessible because it has twist-type hardware. |
TR10 |
24 months |
5.6i |
The urinal is inaccessible because the rim is 25 inches above the finished floor and the flush is 46 inches above the finished floor. |
TR20 |
24 months |
5.6j |
No accessible stall has been provided. |
ST15 |
24 months |
5.7 |
Women's Single-User Toilet Room Near Game Room |
|
|
5.7a |
There is no signage directing people with disabilities to the accessible toilet rooms. |
TR16 |
24 months |
5.7b |
Men's Single-User Toilet Room Near Game Room |
|
|
5.7c |
There is no signage directing people with disabilities to the accessible toilet rooms. |
TR16 |
24 months |
6 |
The City will correct the following items at Gadsden Sports Complex, located at 1700 Meighan Boulevard: |
|
|
6.1 |
Parking |
|
|
6.1a |
At the Softball and Baseball fields - Although the parking lot has a total of 86 parking spaces, only 2 are designated as reserved for people with disabilities, there are no access aisles provided, there is no van accessible space, and there is only one vertical sign. This lot requires one van accessible space and three standard spaces. |
P3 |
24 months |
6.1b |
At the Tennis Complex and Soccer fields - Although the parking lot has a total of 164 parking spaces, only 4 are designated as reserved for people with disabilities, there are no access aisles provided, and there is no van accessible space. This lot requires one van accessible space and five standard spaces. |
P3 |
24 months |
6.2 |
Concession Stand, Toilet Room, and Broadcast Booth Facility at Ball Fields |
|
|
6.2a |
The route from the parking lot near the softball fields to the concession stand and toilet room building is inaccessible because the window-unit style air conditioners protrude into the main walkway and are not detectable to a blind person using a cane. |
AR8 |
24 months |
6.2b |
No access to the upper level of the facility, which houses the broadcast booth, is provided for people with mobility disabilities. The stairs lack handrails on both sides, which limits access for people with mobility disabilities who may be able to walk up to the booth; and the booth is completely inaccessible to persons who use wheelchairs. |
AR9 |
24 months |
6.3 |
Women's Toilet Room - with stalls (near softball concession) |
|
|
6.3a |
The signage provided is inaccessible because it is not mounted on the latch side of the door and it lacks raised and Braille characters. |
TR17 |
24 months |
6.3b |
The paper towel dispenser is inaccessible because it is mounted with the controls 58 inches above the finished floor. |
TR5 |
24 months |
6.3c |
The path of travel inside the toilet room is inaccessible because the air dryer and paper towel dispenser protrude into the walkway and are not detectable to blind persons using a cane. |
AR8 |
24 months |
6.3d |
The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact. |
TR12 |
24 months |
6.3e |
The lavatory is inaccessible because it has twist-type hardware. |
TR10 |
24 months |
6.3f |
No accessible stall has been provided. |
ST15 |
24 months |
6.4 |
Men's Toilet Room - with stalls (near softball concession) |
|
|
6.4a |
The signage provided is inaccessible because it is not mounted on the latch side of the door and it lacks raised and Braille characters. |
TR17 |
24 months |
6.4b |
The pull side of the door, which is accessed through a front approach, is inaccessible because it has only 14 inches of clear space on the latch side. |
D6 |
24 months |
6.4c |
The paper towel dispenser is inaccessible because it is mounted with the controls 63 inches above the finished floor. |
TR5 |
24 months |
6.4d |
The path of travel inside the toilet room is inaccessible because the lavatories and air dryer protrude into the walkway and are not detectable to blind persons using a cane. |
AR8 |
24 months |
6.4e |
The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact. |
TR12 |
24 months |
6.4f |
The lavatory is inaccessible because it has twist-type hardware. |
TR10 |
24 months |
6.4g |
The urinal is inaccessible because the rim is 19 inches above the finished floor. |
TR20 |
24 months |
6.4h |
There is no accessible stall provided. |
ST15 |
24 months |
6.5 |
Counters |
|
|
6.5a |
None of the ticket counters is accessible because they are too high. |
C6 |
24 months |
6.5b |
None of the concession counters is accessible because they are too high. |
C4 |
24 months |
6.6 |
Picnic Tables |
|
|
6.6a |
The picnic tables are inaccessible because they are not located on an accessible route and do not provide the required knee space. |
PD6 |
24 months |
6.7 |
Ticket Counters, Concession Stand, Toilet Room, and Broadcast Booth Facility at Soccer and Pee-Wee Football fields |
|
|
6.7a |
No access to the upper level of the facility, which houses the broadcast booth, is provided for people with mobility disabilities. The stairs lack handrails on both sides, which limits access for those with mobility disabilities who may be able to walk up to the booth; and the booth is completely inaccessible to persons who use wheelchairs. |
AR9 |
24 months |
6.8 |
Counters |
|
|
6.8a |
None of the ticket counters is accessible because they are too high. |
C6 |
24 months |
6.8b |
None of the concession counters is accessible because they are too high. |
C4 |
24 months |
6.9 |
Women's Toilet Room - with stalls |
|
|
6.9a |
The signage provided is inaccessible because it is not mounted on the latch side of the door and it lacks raised and Braille characters. |
TR17 |
24 months |
6.9b |
The door is inaccessible because knob hardware is used. |
D1 |
24 months |
6.9c |
The pull side of the door, which is accessed through a front approach, is inaccessible because it has insufficient maneuvering clearance, and the push side of the door, which is accessed through a front approach and which has both a closer and a latch, is inaccessible because it has insufficient maneuvering clearance. |
D6; D7 |
24 months |
6.9d |
The paper towel dispenser protrudes into the walkway and is not detectable to blind persons using a cane. |
AR8 |
24 months |
6.9e |
The lavatory is inaccessible because it has twist-type hardware. |
TR10 |
24 months |
6.9f |
No accessible stall has been provided. |
ST15 |
24 months |
6.10 |
Men's Toilet Room - with stalls |
|
|
6.10a |
The signage provided is inaccessible because it is not mounted on the latch side of the door, the centerline is 63 inches above the finished floor, and it lacks raised and Braille characters. |
TR17 |
24 months |
6.10b |
The door is inaccessible because knob hardware is used. |
D1 |
24 months |
6.10c |
The push side of the door, which is accessed through a front approach and which has both a closer and a latch, is inaccessible because it has insufficient maneuvering clearance. |
D7 |
24 months |
6.10d |
The paper towel dispenser is inaccessible because it is mounted 63 inches above the finished floor behind the lavatory. |
TR4 |
24 months |
6.10e |
The lavatory is inaccessible because it has twist-type hardware. |
TR10 |
24 months |
6.10f |
No accessible stall has been provided. |
ST15 |
24 months |
6.11 |
Tennis Complex |
|
|
6.11a |
The Tennis Pro Shop entrances are inaccessible because they lack level landing areas and they have knob hardware. |
D17 |
24 months |
6.11b |
The retail counter at the pro shop is inaccessible because its top surface is 49 inches above the finished floor. |
C5 |
24 months |
6.11c |
The drinking fountain is inaccessible because its spout is 44 inches above the finished floor. |
DF6 |
24 months |
6.11d |
The door is inaccessible because knob hardware is used. |
D1 |
24 months |
6.12 |
Women's Locker Room - with stalls |
|
|
6.12a |
The signage provided is inaccessible because it is not mounted on the latch side of the door and it lacks raised and Braille characters. |
TR17 |
24 months
|
6.12b |
The door is inaccessible because knob hardware is used. |
D1 |
24 months |
6.12c |
The locker room door, which is accessed through a front approach and which has both a closer and a latch, is inaccessible because it has insufficient maneuvering clearance on both the pull and push side. |
D6; D7 |
24 months |
6.12d |
No accessible mirror has been provided. |
TR14 |
24 months |
6.12e |
The lavatory is inaccessible because it has twist-type hardware. |
TR10 |
24 months |
6.12f |
The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact. |
TR12 |
24 months |
6.12g |
No accessible stall is provided. |
ST15 |
24 months |
6.12h |
No accessible shower is provided. |
B8 |
24 months |
6.12i |
No accessible locker is provided. |
LR3 |
24 months |
6.13 |
Men's Locker Room - with stalls |
|
|
6.13a |
The signage provided is inaccessible because it is not mounted on the latch side of the door, and it lacks raised and Braille characters. |
TR17 |
24 months
|
6.13b |
The door is inaccessible because knob hardware is used. |
D1 |
24 months |
6.13c |
The pull side of the door, which is accessed from the latch side of the door, is inaccessible because it has insufficient maneuvering clearance. |
D10 |
24 months |
6.13d |
No accessible mirror has been provided. |
TR14 |
24 months |
6.13e |
The lavatory is inaccessible because it has twist-type hardware. |
TR10 |
24 months |
6.13f |
The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact. |
TR12 |
24 months |
6.13g |
The urinal is inaccessible because the rim is too high. |
TR20
|
24 months |
6.13h |
No accessible stall has been provided. |
ST15 |
24 months |
6.13i |
No accessible shower has been provided. |
B8 |
24 months |
6.13j |
No accessible locker has been provided. |
LR3 |
24 months |
7. |
The City will correct the following items at Jack Gaston Coliseum, located at 1420 Meighan Boulevard: |
|
|
7.1 |
Parking |
|
|
7.1a |
The parking lot is inaccessible because although it has three designated accessible parking spaces, 2 have no access aisles, 1 has no vertical signage, and 1 has poles obstructing the access aisle. This lot requires one van accessible space and two standard spaces. |
P3 |
24 months |
7.1b |
The curb ramp is inaccessible because it does not have flared sides and the bottom does not have a smooth transition. |
AR5 |
24 months |
7.2 |
The concession counter in the lobby is inaccessible because its top surface is 49 inches above the finished floor. |
C5 |
24 months |
7.3 |
The gym door is inaccessible because it requires 8 pounds of force to open. |
D2 |
24 months |
7.4 |
The drinking fountain in the lobby near the women's toilet room is inaccessible because its spout is 44 inches above the finished floor. |
DF6 |
24 months |
7.5 |
Women's Toilet Room - with stalls |
|
|
7.5a |
The route to the toilet room is inaccessible because it is less than 36 inches wide due to the presence of the table in the hall. |
AR3 |
24 months |
7.5b |
The signage provided is inaccessible because it is not mounted on the latch side of the door, the centerline is 73 inches above the finished floor, and it lacks raised and Braille characters. |
TR17 |
24 months |
7.5c |
The door is inaccessible because it requires 11 pounds of force to open. |
D2 |
24 months |
7.5d |
The lavatory is inaccessible because the push style hardware requires 18 pounds of force to operate. |
TR10 |
24 months |
7.5e |
The paper towel dispenser protrudes into the walkway and is not detectable to blind persons using a cane. |
AR8 |
24 months |
7.5f |
No accessible stall has been provided. |
ST15 |
24 months |
7.6 |
Men's Toilet Room - with stalls |
|
|
7.6a |
The signage provided is inaccessible because it is not mounted on the latch side of the door, the centerline is 73 inches above the finished floor, and it lacks raised and Braille characters. |
TR17 |
24 months |
7.6b |
The door is inaccessible because it requires 8 pounds of force to open. |
D2 |
24 months |
7.6c |
The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact. |
TR12 |
24 months |
7.6d |
The lavatory is inaccessible because the push style hardware requires more than 5 pounds of force to operate. |
TR10 |
24 months |
7.6e |
The paper towel dispenser protrudes into the walkway and is not detectable to blind persons using a cane. |
AR8 |
24 months |
7.6f |
The urinal is inaccessible because the rim is 20 inches above the finished floor. |
TR20 |
24 months |
7.6g |
No accessible stall has been provided. |
ST15 |
24 months |
8. |
The City will correct the following items at Noccalula Falls Park and Campground, located at 1600 Noccalula Road: |
|
|
8.1 |
Parking |
|
|
8.1a |
At the Main Entrance, which includes parking for Jack's restaurant and the playground, the parking lot, with a total of 47 parking spaces, is inaccessible because it has an insufficient number of spaces reserved for people with disabilities. This lot requires one van accessible space and one standard space. The parking lot is also inaccessible because the access aisles are too small. In addition, the parking reserved for persons with disabilities is inaccessible because it lacks appropriate vertical signage. |
P3 |
24 months |
8.1b |
At the Kiwanis Building and Pavilions, the parking lot, with a total of 33 parking spaces, is inaccessible because it has an insufficient number of spaces reserved for people with disabilities. The accessible parking also lacks access aisles. This lot requires one van accessible space and one standard space. |
P3 |
24 months |
8.1c |
The Overflow Lot, with a total of 205 parking spaces, is inaccessible because it has an insufficient number of spaces designated as accessible. In addition, the accessible parking has no access aisles or vertical signage. This lot requires one van accessible space and six standard spaces. |
P3 |
24 months |
8.2 |
Accessible Routes |
|
|
8.2a |
The route from the main entrance parking lot to the playground is inaccessible because the gravel surface is not firm, stable, and slip resistant. |
AR1 |
24 months |
8.2b |
The route from the playground to the Falls viewing area is inaccessible because the rocky and uneven surface is not firm, stable, and slip resistant. |
AR1 |
24 months |
8.2c |
The route to the Concession Stand is inaccessible because the gravel surface is not firm, stable, and slip resistant. |
AR1 |
24 months |
8.2d |
The route from the overflow parking area to the pedestrian bridge is inaccessible because the sidewalk is cracked and has a 10.5% cross-slope. |
AR1 |
24 months |
8.2e |
The route to the Pavilion is inaccessible because it has a running slope of 12.4% and a cross slope of 3.7%. |
AR1 |
24 months |
8.2f |
The path to the Kiwanis Building and Pavilions is inaccessible because it has a running slope of 7.8% and is not constructed as a ramp. |
AR1 |
24 months |
8.3 |
Concession Stand |
|
|
8.3a |
The retail counter is inaccessible because its top surface is 42 ½ inches above the finished floor. |
C5 |
24 months |
8.4 |
Picnic Tables |
|
|
8.4a |
The picnic tables are inaccessible because none provide the required knee space. |
PD6 |
24 months |
8.5 |
Campground Area |
|
|
8.5a |
The laundry machine controls, soap dispenser, and paper towel dispenser are inaccessible because they are too high. |
TR5 |
24 months |
8.5b |
The service counters in the Pavilion are inaccessible because their top surfaces are 44 ½ inches and 47 inches above the finished floor. |
C4 |
24 months |
8.5c |
The routes to the camp store, laundry, and pavilion are inaccessible. |
AR1 |
24 months |
8.6 |
Women's Toilet and Shower Room in Camp Office - with stalls |
|
|
8.6a |
The signage provided is inaccessible. |
TR17 |
24 months |
8.6b |
The paper towel dispenser is inaccessible because it is mounted with the controls 59 inches above the finished floor. |
TR5 |
24 months |
8.6c |
The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact. |
TR12 |
24 months |
8.6d |
The lavatory is inaccessible because it has twist-type hardware. |
TR10 |
24 months |
8.6e |
No accessible stall has been provided. |
ST15 |
24 months |
8.6f |
No accessible shower has been provided. |
B8 |
24 months |
8.6g |
No accessible towel hook has been provided. |
TR5 |
24 months |
8.6h |
The bench is inaccessible because it is less than 24 inches deep and it is not fixed to the wall. |
LR1 |
24 months |
8.7 |
Men's Toilet and Shower Room in Camp Office - with Stalls |
|
|
8.7a |
The signage provided is inaccessible. |
TR17 |
24 months |
8.7b |
The pull side of the door, which is accessed through a front approach, is inaccessible because it has insufficient clear space on the latch side. |
D6 |
24 months |
8.7c |
The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact. |
TR12 |
24 months |
8.7d |
The lavatory is inaccessible because it has twist-type hardware. |
TR10 |
24 months |
8.7e |
The urinal is inaccessible because the rim is 21 3/4 inches above the finished floor. |
TR20 |
24 months |
8.7f |
No accessible stall has been provided. |
ST15 |
24 months |
8.7g |
No accessible shower has been provided. |
B8 |
24 months |
8.7h |
No accessible towel hook has been provided. |
TR5 |
24 months |
8.7i |
The bench is inaccessible because it is less than 24 inches deep and it is not fixed to the wall. |
LR1 |
24 months |
8.8 |
Women's and Men's Toilet and Shower Rooms with Stalls - Campground |
|
|
8.8a |
The signage provided is inaccessible. |
TR17 |
24 months |
8.8b |
The route is inaccessible because it has an abrupt vertical rise greater than ½ inch. |
AR2 |
24 months |
8.8c |
The entrance doors are inaccessible because knob hardware is used. |
D1 |
24 months |
8.8d |
The pull side of the doors, which is accessed from the latch side of the door, is inaccessible because there is insufficient clear space on the latch side. |
D10 |
24 months |
8.8e |
The lavatory is inaccessible because the cabinets underneath do not allow for the required knee and toe clearances. |
TR9 |
24 months |
8.8f |
In each room, no accessible stall has been provided. |
ST15 |
24 months |
8.8g |
In each room, no accessible shower has been provided. |
B8 |
24 months |
8.8h |
The benches are inaccessible because they are less than 24 inches deep and are not fixed to the wall. |
LR1 |
24 months
|
8.9 |
Drinking Fountains |
|
|
8.9a |
In the Kiwanis Building, the drinking fountain is inaccessible because it has a spout that is 42 inches above the finished floor and lacks sufficient knee space. |
DF1 |
24 months |
8.9b |
In the Park Office, near the supervisor's office, the drinking fountain is inaccessible because it has a spout that is 40 inches above the finished floor and lacks sufficient knee space. |
DF1 |
24 months |
8.10 |
Kiwanis Building |
|
|
8.10a |
The service counter near the supervisor's office is inaccessible because its top surface is 42 inches above the finished floor. |
C6 |
24 months |
8.10b |
The interior doors in the building are inaccessible because knob hardware is used. |
D1 |
24 months |
8.10c |
Women's Toilet Room in Kiwanis Building - with stalls |
||
8.10c.i |
The signage provided is inaccessible. |
TR17 |
24 months |
8.10c.ii |
The door is inaccessible because it requires 14 pounds of force to open. |
D2 |
24 months |
8.10c.iii |
The pull side of the door, which is accessed through a front approach, is inaccessible because it has only 10 inches of clear space on the latch side. |
D6 |
24 months |
8.10c.iv |
The paper towel dispenser is inaccessible because it is mounted with the controls 53 ½ inches above the finished floor. |
TR5 |
24 months |
8.10c.v |
The lavatory is inaccessible because it has twist-type hardware. |
TR10 |
24 months |
8.10c.vi |
The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact. |
TR12 |
24 months |
8.10c.vii |
No accessible stall has been provided. |
ST15 |
24 months |
8.10c.viii |
The ambulatory stall is inaccessible because the stall partitions are 40 inches apart, the toilet centerline is 15 ½ from the side wall, and one side grab bar is obstructed by the toilet paper dispenser. |
ST1; ST8 |
24 months |
8.10c.ix |
No accessible coat hook has been provided. |
TR1 |
24 months |
8.10d |
Men's Toilet Room in Kiwanis Building - with stalls |
|
|
8.10d.i |
The signage provided is inaccessible. |
TR17 |
24 months |
8.10d.ii |
The door is inaccessible because it requires 14 pounds of force to open. |
D2 |
24 months |
8.10d.iii |
The pull side of the door, which is accessed through a front approach, is inaccessible because it has only 18 inches of clear space on the latch side. |
D6 |
24 months |
8.10d.iiii |
No accessible mirror has been provided. |
TR14 |
24 months |
8.10d.iv |
The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact. |
TR12 |
24 months |
8.10d.v |
The urinal is inaccessible because the rim is 20 inches above the finished floor and the flush is 47 inches above the finished floor. |
TR20 |
24 months |
8.10d.vii |
No accessible stall has been provided. |
ST15 |
24 months |
8.11 |
The City will correct the following items at the Parks and Recreation Office, located at 90 Walnut Street: |
|
|
8.11a |
The route from the parking lot to the office entrance is inaccessible because there are 2 sloped paths with running slopes of 11.2% and 12.5%. |
AR1 |
24 months |
8.12 |
The City will correct the following items at the Police Department, located at 90 Broad Street: |
|
|
8.12a |
The route from the on-street parking area to the Police Department has a running slope of 7.6% and is not designed as a ramp. |
AR1 |
24 months |
8.12b |
Women's Toilet Room - Single User |
|
|
8.12b.i |
The door is inaccessible because it requires 12 pounds of force to open. |
D2 |
24 months |
8.12b.ii |
No accessible coat hook has been provided. |
TR1 |
24 months |
8.12b.iii |
The side grab bar at the toilet is inaccessible because it is obstructed by the toilet paper dispenser. |
SU7 |
24 months |
8.12b.iv |
The toilet is inaccessible because its centerline is 19 1/4 inches from the side wall. |
SU15 |
24 months |
8.12b.v |
The rear grab bar at the toilet is inaccessible because it is obstructed by the air freshener. |
SU4 |
24 months |
8.12c |
Men's Toilet Room - Single User |
|
|
8.12c.i |
No accessible coat hook has been provided. |
TR1 |
24 months |
8.12c.ii |
The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact. |
TR12 |
24 months |
8.12c.iii |
The urinal is inaccessible because the rim is 20 inches above the finished floor. |
TR20 |
24 months |
8.12c.iv |
The designated accessible toilet is inaccessible because the flush control is on the closed side. |
ST2 |
24 months |
8.12c.v |
The side grab bar at the designated accessible toilet is inaccessible because it is obstructed by the toilet paper dispenser. |
ST8 |
24 months |
8.12c.vi |
The rear grab bar at the toilet is inaccessible because it is obstructed by the air freshener. |
SU4 |
24 months |