ATTACHMENT I: Modifications to Newly Constructed Facilities

Please Note: Paragraph 44 of the Settlement Agreement requires that within three months of the effective date of this Agreement, the City provide signage as necessary to comply with 28 C.F.R. § 35.163(b), after having surveyed all facilities that are the subject of this Agreement for the purpose of identifying those that have multiple entrances not all of which are accessible.

The chart below lists the facilities surveyed by the Department, the access issues identified during the survey, and the actions required to correct the access issues. Required actions are listed using an alphanumeric code. The key to the alphanumeric codes is provided in Attachment M to this Agreement.

In order to ensure that the following spaces and elements in City facilities for which construction was commenced after January 26, 1992, are readily accessible to and usable by persons with disabilities, the City will take the actions referenced by the alphanumeric code and described in detail in Attachment M to this Settlement Agreement within the time periods specified below, which time periods will begin to run on the effective date of this Agreement.

item #

Access Issue

Required Action

Completion Date

1.

Business Development Center - 3901 Dr. Martin Luther King Boulevard

   

1.1.

Main Reception Area Single User Unisex Toilet Room on the Righ

   

1.1.a.

The door is inaccessible because it requires 7 pounds of force to open.

D2

12 months

1.1.b.

The side grab bar at the toilet is inaccessible because it is obstructed by the toilet paper dispenser.

SU7

12 months

1.2.

Main Reception Area Single User Unisex Toilet Room on the Left

   

1.2.a.

The door is inaccessible because it requires 6 pounds of force to open.

D2

12 months

1.2.b.

The side grab bar at the toilet is inaccessible because it is obstructed by the toilet paper dispenser.

SU7

12 months

1.3.

Exterior Single User Unisex Toilet Rooms

   

1.3.a.

The side grab bar at each toilet is inaccessible because it is obstructed by the toilet paper dispenser.

SU7

12 months

1.3.b.

The toilet paper dispenser in 2 of the rooms is inaccessible because it is mounted 40 inches from the rear wall.

SU17

12 months

1.4.

Picnic Tables between Exterior Unisex Toilet Rooms: The picnic tables are inaccessible because none provide the required knee space.

PD6

12 months

1.5.

West Alcove Drinking Fountain: The drinking fountain is inaccessible because the controls require 7 pounds of force to operate.

DF2

12 months

1.6.

East Alcove Drinking Fountain: The drinking fountain is inaccessible because the controls require 11 pounds of force to operate, and the flow of water is 3 inches high and 4 inches from the front of the fountain.

DF1

12 months

2.

City Pier Building - 1300 Hendry Street

   

2.1.

Front Entrance

   

2.1.a.

The mailboxes in the vestibule protrude into the walkway and are not detectable to blind persons using a cane.

AR8

12 months

2.1.b.

The alcove under the stairway in the vestibule is an overhead hazard.

AR7

12 months

2.1.c.

The interior door is inaccessible because it requires 14 pounds of force to open.

D2

12 months

2.1.d.

The entrance ramp is inaccessible because it has a slope of up to 9.9%, the handrails are not stable or continuous, one intermediate landing is 58½ inches wide, and the handrail is mounted 4¼ inches from the wall.

R3

12 months

2.2.

1st Floor Drinking Fountain

   

2.2.a.

The drinking fountain is inaccessible because the controls require 7 pounds of force to operate.

DF2

12 months

2.2.b.

The drinking fountain is inaccessible because the spout is 3½ inches from the front of the fountain.

DF1

12 months

2.2.c.

Although a designated accessible drinking fountain is provided, there is no drinking fountain provided for people who have difficulty bending or stooping.

DF3

12 months

2.3.

Single User Toilet Room in 1st Floor WomenÕs Toilet Room

   

2.3.a.

The door to the main toilet room is inaccessible because it requires 6 pounds of force to open.

D2

12 months

2.3.b.

The pull side of the door to the single user toilet room, which is accessed through a front approach, is inaccessible because it has only 3 inches of clear space on the latch side.

D6

12 months

2.3.c.

No accessible mirror has been provided.

TR14

12 months

2.3.d.

The side grab bar at the toilet is inaccessible because it is mounted 32½ inches above the finished floor.

SU11

12 months

2.3.e.

The rear grab bar at the toilet is inaccessible because it is obstructed by the toilet seat cover dispenser.

SU4

12 months

2.4.

Single User Toilet Room in 1st Floor MenÕs Toilet Room

   

2.4.a.

No accessible mirror has been provided.

TR14

12 months

2.4.b.

The toilet paper dispenser is inaccessible because it is mounted 44 inches from the rear wall.

SU17

12 months

2.4.c.

The rear grab bar at the toilet is inaccessible because it is obstructed by the toilet seat cover dispenser.

SU4

12 months

2.5.

Elevators

   

2.5.a.

The hall lanterns are inaccessible because the signals are not visible from the area of the hall call buttons.

E11

12 months

2.5.b.

The elevator is inaccessible because the time between the doors reopening due to an obstruction and the doors closing is 2 seconds.

E6

12 months

2.5.c.

The elevator is inaccessible because the emergency system requires voice communication to operate, and it requires tight grasping or pinching to access.

E8

12 months

2.6.

2nd Floor Drinking Fountain

   

2.6.a.

The drinking fountain is inaccessible because the flow of water is 3½ inches from the front of the fountain.

DF7

12 months

2.6.b.

Although a designated accessible drinking fountain is provided, there is no drinking fountain provided for people who have difficulty bending or stooping.

DF3

12 months

2.7.

Single User Toilet Room in 2nd Floor WomenÕs Toilet Room

   

2.7.a.

The door to the main toilet room is inaccessible because it requires 8 pounds of force to open.

D2

12 months

2.7.b.

The pull side of the door to the single user toilet room, which is accessed through a front approach, is inaccessible because it has less than 18 inches of clear space on the latch side.

D6

12 months

2.7.c.

The toilet is inaccessible because its centerline is 18¾ inches from the side wall.

SU15

12 months

2.7.d.

The toilet paper dispenser is inaccessible because it is mounted 43 inches from the rear wall.

SU17

12 months

2.7.e.

The side grab bar at the toilet is inaccessible because it is mounted 12½ inches from the rear wall.

SU6

12 months

2.7.f.

The rear grab bar at the toilet is inaccessible because it is obstructed by the seat cover dispenser and the soap dispenser.

SU4

12 months

2.8.

Single User Toilet Room in 2nd Floor MenÕs Toilet Room

   

2.8.a.

The door is inaccessible because it requires 7 pounds of force to open.

D2

12 months

2.8.b.

The lavatory is inaccessible because the bottom edge of the apron is 28½ inches above the finished floor.

TR11

12 months

2.8.c.

The toilet paper dispenser is inaccessible because it is mounted 43 inches from the rear wall.

SU17

12 months

2.8.d.

The rear grab bar at the toilet is inaccessible because it is obstructed by the seat cover dispenser and the soap dispenser.

SU4

12 months

3.

Fire Station #4 - 4520 Cummins Court

   

3.1.

Parking: The designated accessible parking space at the back of the building is inaccessible because it has no access aisle.

P5

12 months

3.2.

Entrances

   

3.2.a.

The ramp to the side entrance is inaccessible because it has no handrails, and the top landing is only 41½ inches deep.

R5

12 months

3.2.b.

The pull side of the rear entrance door, which is accessed through a front approach, is inaccessible because it has insufficient clear space on the latch side and only 41½ inches of maneuvering depth.

D6

12 months

3.2.c.

The entrance doors are inaccessible because knob hardware is used.

D1

12 months

3.2.d.

The side entrance is blocked by equipment on the inside.

AR3

12 months

3.3.

Interior Doors

   

3.3.a.

The interior doors throughout the facility are inaccessible because knob hardware is used.

D1

12 months

3.3.b.

The interior doors throughout the facility are inaccessible because they require more than 5 pounds of force to open.

D2

12 months

3.4.

Locker Rooms: The locker rooms contain a number of inaccessible elements and are not accessible to people with disabilities.

LR4

12 months

3.5.

Drinking Fountain in Equipment Room

   

3.5.a.

The drinking fountain is inaccessible because the flow of water is 3½ inches from the front of the fountain.

DF7

12 months

3.5.b.

Although a designated accessible drinking fountain is provided, there is no drinking fountain provided for people who have difficulty bending or stooping.

DF3

12 months

3.6.

Single User Toilet Room by Equipment Room: The room contains a number of inaccessible elements and is not accessible to people with disabilities.

SU13

12 months

4.

Sam Fleishman Regional Sports Complex - Baseball Fields - 1750 Matthew Drive

 

4.1.

Parking: Several of the curb ramps are inaccessible because they have slopes exceeding 8.33%.

AR5

12 months

4.2.

John Nelson Stadium - Field #7: The baseball seating area is inaccessible because there is no ramp to access it, no companion seats are provided, and it is not integrated with the rest of the seating area.

AA7

12 months

4.3.

Maintenance Facility Unisex Single User Toilet Room

   

4.3.a.

The toilet is inaccessible because the top of the seat is 16½ inches above the finished floor.

SU18

12 months

4.3.b.

The toilet is inaccessible because a shelf obstructs the clear floor space.

SU16

12 months

4.3.c.

The shelf protrudes into the walkway and is not detectable to blind persons using a cane.

AR8

12 months

4.3.d.

The toilet paper dispenser is inaccessible because it is mounted more than 36 inches from the rear wall.

SU17

12 months

4.4.

Press/Concession Building Lift

   

4.4.a.

The lift is inaccessible because the interior is only 46½ inches deep.

LF2

12 months

4.4.b.

The lift is inaccessible because it requires that a key be obtained from an employee before the lift can be operated.

LF1

12 months

4.4.c.

The lift is inaccessible because it is being used for storage.

M2

12 months

4.5.

Snack Bar in Press Box Building

   

4.5.a.

The kitchen sink is inaccessible because the hot water and drain pipes are not insulated or otherwise configured to protect against contact.

S2

12 months

4.5.b.

Although a designated accessible drinking fountain is provided, there is no drinking fountain provided for people who have difficulty bending or stooping.

DF3

12 months

4.6.

Picnic Tables: The picnic tables throughout the facility are inaccessible because none provide the required knee space.

PD6

12 months

4.7.

WomenÕs Single User Toilet Room in Press/Concession Building

   

4.7.a.

The toilet room sign is inaccessible because it is mounted 65½ inches above the finished floor.

TR18

12 months

4.7.b.

The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact.

TR12

12 months

4.7.c.

The toilet is inaccessible because the top of the seat is 16 inches above the finished floor.

SU18

12 months

4.7.d.

The toilet is inaccessible because there are no grab bars provided.

SU10

12 months

4.8.

MenÕs Single User Toilet Room in Press/Concession Building

   

4.8.a.

The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact.

TR12

12 months

4.8.b.

The urinal is inaccessible because the rim is 24¼ inches above the finished floor and the flush control is 51 inches above the finished floor.

TR20

12 months

4.8.c.

The toilet is inaccessible because the top of the seat is 16 inches above the finished floor.

SU18

12 months

4.8.d.

The toilet is inaccessible because the flush control is on the closed side.

SU1

12 months

4.8.e.

The toilet is inaccessible because its centerline is 19½ inches from the side wall.

SU15

12 months

4.8.f.

The toilet is inaccessible because there are no grab bars provided.

SU10

12 months

4.8.g.

The toilet is inaccessible because the urinal obstructs the clear floor space.

SU16

12 months

4.9.

Ballfields

   

4.9.a.

Some of the dugouts are inaccessible because they can be accessed only by steps.

AR1

12 months

4.9.b.

Many of the fields are inaccessible because the routes to them are not firm, stable, and slip resistant.

AR1

12 months

4.9.c.

The batting cages are inaccessible because the route is not firm, stable, and slip resistant.

AR1

12 months

5.

Sam Fleishman Regional Sports Complex - Aquatic Center - 1750 Matthew Drive

 

5.1.

Parking: The parking lot, with a total of 78 parking spaces, is inaccessible because it only has 1 space designated as accessible. This lot requires 1 van accessible space and 4 standard accessible spaces.

P3

12 months

5.2.

Route to Entrance

   

5.2.a.

The curb ramp by the facility entrance is inaccessible because it has a slope of 11% and the side flares have slopes of 19.5 % and 15.3%.

AR5

12 months

5.2.b.

The curb ramp in front of the designated accessible parking space is inaccessible because it has a slope of 10.1%.

AR5

12 months

5.3.

Entrance Counter: The counter is inaccessible because it is 42 inches above the finished floor.

C6

12 months

5.4.

Drinking Fountain: Although a designated accessible drinking fountain is provided, there is no drinking fountain provided for people who have difficulty bending or stooping.

DF3

12 months

5.5.

Kiddie Pool

   

5.5.a.

The counter is inaccessible because it is 42 inches above the finished floor.

C6

12 months

5.5.b.

The operating mechanism for the gate between the kiddie pool and the lap lanes is inaccessible because it is mounted 60 inches above the finished floor.

D1

12 months

5.6.

Snack Bar: The counter is inaccessible because it is 42 inches above the finished floor.

C5

12 months

5.7.

MenÕs Locker Room

   

5.7.a.

The lavatory is inaccessible because the bottom edge of the apron is 28 inches above the finished floor.

TR11

12 months

5.7.b.

The designated accessible toilet is inaccessible because the flush control is on the closed side.

ST2

12 months

5.7.c.

The side grab bar at the designated accessible toilet is inaccessible because it is obstructed by the toilet paper dispenser.

ST8

12 months

5.7.d.

The side grab bar at the designated accessible toilet is inaccessible because it is mounted 12½ inches from the rear wall.

ST7

12 months

5.7.e.

The rear grab bar at the designated accessible toilet is inaccessible because it is mounted 12 inches from the side wall.

ST4

12 months

5.7.f.

The designated accessible toilet is inaccessible because the rear grab bar is obstructed by the paper towel dispenser.

ST5

12 months

5.7.g.

The designated accessible roll-in shower is inaccessible because the clear floor space at the entry is less than 60 inches wide, there is no handheld shower spray unit, the fixed shower head is mounted approximately 72 inches above the finished floor, and the floor slopes 8.9%.

B8

12 months

5.7.h.

No accessible towel or clothes hooks have been provided.

TR1

12 months

5.7.i.

The bench is inaccessible because it is 9 inches deep.

LR1

12 months

5.8.

WomenÕs Locker Room

   

5.8.a.

The side grab bar at the designated accessible toilet is inaccessible because it is obstructed by the toilet paper dispenser and the trash receptacle.

ST8

12 months

5.8.b.

The side grab bar at the designated accessible toilet is inaccessible because it is mounted 13 inches from the rear wall.

ST7

12 months

5.8.c.

The rear grab bar at the designated accessible toilet is inaccessible because it is mounted 12 inches from the side wall.

ST4

12 months

5.8.d.

The designated accessible toilet is inaccessible because the rear grab bar is obstructed by the paper towel dispenser.

ST5

12 months

5.8.e.

The ambulatory stall is inaccessible because the partitions are 37 inches apart; the toilet seat is 20¼ inches above the finished floor; one grab bar is mounted 12½ inches from the rear wall; and the toilet paper dispenser interferes with the use of the grab bar.

ST1

12 months

5.8.f.

The designated accessible roll-in shower is inaccessible because it is 58 inches wide, the clear floor space at the entry is less than 60 inches wide, there is no handheld shower spray unit, the fixed shower head is mounted approximately 72 inches above the finished floor, and the floor slopes 8.9%.

B8

12 months

5.8.g.

The bench is inaccessible because it is 9 inches deep and 16½ inches above the finished floor.

LR1

12 months

6.

Sam Fleishman Regional Sports Complex - Racquet Club - 1750 Matthew Drive

 

6.1.

Parking: The parking is inaccessible because 3 of the designated accessible parking spaces have slopes between 3.1% and 4.7%.

P7

12 months

6.2.

Entrance: There is a slope of 5.9% near the entrance with no ramp features provided.

R4

12 months

6.3.

MenÕs Single User Toilet and Shower Room

   

6.3.a.

The toilet room sign is mounted on the door.

TR18

12 months

6.3.b.

Although an audible alarm is provided in this facility, there is no visual alarm appliance in the toilet room.

TR21

12 months

6.3.c.

The bench narrows the path of travel to 28 inches wide.

AR3

12 months

6.3.d.

No accessible towel hook has been provided.

TR1

12 months

6.4.

WomenÕs Single User Toilet and Shower Room

   

6.4.a.

The toilet room sign is mounted on the door.

TR18

12 months

6.4.b.

Although an audible alarm is provided in this facility, there is no visual alarm appliance in the toilet room.

TR21

12 months

6.4.c.

The paper towel dispenser protrudes into the walkway and is not detectable to blind persons using a cane.

AR8

12 months

6.4.d.

The bench narrows the path of travel to 28 inches wide.

AR3

12 months

6.4.e.

No accessible towel hook has been provided.

TR1

12 months

6.5.

Picnic Tables: The picnic tables are inaccessible because none provide the required knee space.

PD6

12 months

6.6.

Exterior Route: The AED protrudes into the walkway and is not detectable to blind persons using a cane.

AR8

12 months

6.7.

Racquet Club Store

   

6.7.a.

The counter is inaccessible because it is 38 inches above the finished floor.

C5

12 months

6.7.b.

The route is inaccessible because it is obstructed with merchandise.

AR3

12 months

7.

Sam Fleishman Regional Sports Complex - Park, Carner Field- 1750 Matthew Drive

 

7.1.

Exterior Routes: The routes to the benches, swing areas, and grills are inaccessible because the surfaces are not firm, stable, and slip resistant.

AR1

12 months

7.2.

Carner Field: The dugouts are inaccessible because there are steps to access them.

AR1

12 months

7.3.

Drinking Fountains near Picnic and Play Areas

   

7.3.a.

The drinking fountains are inaccessible because the flow of water is 7 inches from the fronts of the fountains.

DF7

12 months

7.3.b.

Although designated accessible drinking fountains are provided, there is no drinking fountain provided for people who have difficulty bending or stooping.

DF3

12 months

7.3.c.

The drinking fountains protrude into the walkway and are not detectable to blind persons using a cane.

AR8

12 months

8.

City of Fort Myers Utilities Billing Center - 2925 Martin Luther King, Jr., Boulevard

   

8.1.

Parking: The designated accessible parking spaces and access aisle are inaccessible because they have slopes between 2.5% and 3.4%.

P7

12 months

8.2.

Interior Doors: The interior doors throughout the facility are inaccessible because they require more than 5 pounds of force to open.

D2

12 months

8.3.

Lobby Drinking Fountain: Although a designated accessible drinking fountain is provided, there is no drinking fountain provided for people who have difficulty bending or stooping.

DF3

12 months

8.4.

Lobby Unisex Single User Toilet Room

   

8.4.a.

The toilet room sign is mounted 62 inches above the finished floor.

TR18

12 months

8.4.b.

The pull side of the door, which is accessed through a front approach, is inaccessible because it has 9 inches of clear space on the latch side.

D6

12 months

8.4.c.

The toilet is inaccessible because the flush control is on the closed side.

SU1

12 months

8.5.

Employee Area MenÕs Single User Toilet Room

   

8.5.a.

The toilet is inaccessible because the flush control is on the closed side.

SU1

12 months

8.5.b.

The toilet is inaccessible because there are no grab bars provided.

SU10

12 months

8.6.

Customer Service/Cashier Service: The mail slot is inaccessible because it is 62 inches above the finished floor.

TR5

12 months

9.

Fowler Street

   

9.1.

Gutter Slopes: The curb ramps along Fowler Street generally are inaccessible because they have gutter slopes exceeding 5%.

AR5

12 months

9.2.

East Side of Fowler Street between Simpson and Welch Streets: The route across the gas station driveway is inaccessible because it slopes up to 9.4% on the south side.

AR1

12 months

9.3.

East Side of Fowler Street at Welch Street

   

9.3.a.

The curb ramp on the southeast corner is inaccessible because it has a slope of 9%.

AR5

12 months

9.3.b.

The curb ramp on the northeast corner is inaccessible because it has a slope of 9.2%.

AR5

12 months

9.4.

East Side of Fowler Street at Hunter Terrace

   

9.4.a.

The curb ramp on the southeast corner is inaccessible because it has a cross slope of 4.1%.

AR5

12 months

9.4.b.

The curb ramp on the northeast corner is inaccessible because it has a cross slope of 7%.

AR5

12 months

9.5.

East Side of Fowler Street at Hunter Street

   

9.5.a.

The curb ramp on the southeast corner is inaccessible because it has a slope of 9% and a cross slope of 5.7%.

AR5

12 months

9.5.b.

The curb ramp on the northeast corner is inaccessible because it has a cross slope of 3.1%.

AR5

12 months

9.6.

East Side of Fowler Street at Parkway Street

   

9.6.a.

The curb ramp on the southeast corner is inaccessible because it has a cross slope of 4.9%.

AR5

12 months

9.6.b.

The curb ramp on the northeast corner is inaccessible because it has a cross slope of 6% .

AR5

12 months

9.7.

East Side of Fowler Street between Parkway and Kennesaw Streets: The route near 3333 Fowler is inaccessible because is has a cross slope of up to 4.8% and tree roots create steps in the pavement 1¼ inches high.

AR1

12 months

9.8.

East Side of Fowler Street at Kennesaw Street: The curb ramp on the southeast corner is inaccessible because it has a cross slope of 6.6%.

AR5

12 months

9.9.

East Side of Fowler Street between Kennesaw and Collins Streets: The route near 3253 Fowler Street is inaccessible because tree roots create unbeveled changes in level in excess of ½ inch high.

AR1

12 months

9.10.

East Side of Fowler Street at Collins Street

   

9.10.a.

The curb ramp on the southeast corner is inaccessible because it has a slope of 9.1% and a cross slope of 4.7%.

AR5

12 months

9.10.b.

The curb ramp on the northeast corner is inaccessible because it has a slope of 8.7% and a cross slope of 10.4% .

AR5

12 months

9.11.

East Side of Fowler Street between Collins and Moreno Streets: The route near 3237 Fowler Street is inaccessible because it has a number of changes in level between 1 inch and 1¾ inches high.

AR1

12 months

9.12.

East Side of Fowler Street at Moreno Street: The curb ramp on the southeast corner is inaccessible because it has a cross slope of 7.1%.

AR5

12 months

9.13.

West Side of Fowler Street at Moreno Street

   

9.13.a.

The curb ramp on the northwest corner is inaccessible because it has a cross slope of 6.4%.

AR5

12 months

9.13.b.

The curb ramp on the southwest corner is inaccessible because it has a cross slope of 8.1% .

AR5

12 months

9.14.

West Side of Fowler Street between Moreno and Kennesaw Streets: The route near 3238 Fowler Street is inaccessible because it has several changes in level between 1 inch and 1¼ inches high.

AR1

12 months

9.15.

West Side of Fowler Street at Kennesaw Street

   

9.15.a.

The curb ramp on the northwest corner is inaccessible because it has a cross slope of 5.4%.

AR5

12 months

9.15.b.

The curb ramp on the southwest corner is inaccessible because it has a cross slope of 7.8% .

AR5

12 months

9.16.

West Side of Fowler Street at Parkway Street

   

9.16.a.

The curb ramp on the northwest corner is inaccessible because it has a cross slope of 4.2%.

AR5

12 months

9.16.b.

The curb ramp on the southwest corner is inaccessible because it has a cross slope of 6.2% .

AR5

12 months

9.17.

West Side of Fowler Street at Hunter Street

   

9.17.a.

The curb ramp on the northwest corner is inaccessible because it has a cross slope of 6.9%.

AR5

12 months

9.17.b.

The curb ramp on the southwest corner is inaccessible because it has a cross slope of 9.1%.

AR5

12 months

9.18.

West Side of Fowler Street at Hunter Terrace

   

9.18.a.

The curb ramp on the northwest corner is inaccessible because it has a cross slope of 6.8%.

AR5

12 months

9.18.b.

The curb ramp on the southwest corner is inaccessible because it has a cross slope of 9.9% .

AR5

12 months

9.19.

West Side of Fowler Street at Welch Street

   

9.19.a.

The curb ramp on the northwest corner is inaccessible because it has a cross slope of 6.6%.

AR5

12 months

9.19.b.

The curb ramp on the southwest corner is inaccessible because it has a cross slope of 4.3% .

AR5

12 months

9.20.

West Side of Fowler Street at Simpson Street: The curb ramp on the southwest corner is inaccessible because it has a cross slope of 11.5% .

AR5

12 months

10.

Tarpon Street Pier - Tarpon Street and Riverside Drive

   

10.1.

Canoe Path: The route to the canoe dump area is inaccessible because it is not firm, stable, and slip resistant.

AR1

12 months

11.

Skatium- 2250 Broadway

   

11.1.

Route from Parking to Entrance

   

11.1.a.

The curb ramps on each side of Crawford Street side are inaccessible because they have gutter slopes of 10.1% and 8.9%.

AR5

12 months

11.1.b.

The route along Broadway in front of the parking lot is inaccessible because there is a change in level ¾ inch high between two pavers.

AR1

12 months

11.2.

Lobby

   

11.2.a.

The skate rental counter protrudes into the walkway and is not detectable to blind persons using a cane.

AR8

12 months

11.2.b.

The AED protrudes into the walkway and is not detectable to blind persons using a cane.

AR8

12 months

11.3.

Alarms: Although the facility contains an emergency alarm system, the alarm system is inaccessible because there are no visual alarms provided in toilet rooms, locker rooms, corridors, and hallways.

AL1

12 months

11.4.

Lobby WomenÕs Toilet Room

   

11.4.a.

The sign is not mounted on the latch side of the door.

TR18

12 months

11.4.b.

The door is inaccessible because it requires 9 pounds of force to open.

D2

12 months

11.4.c.

The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact.

TR12

12 months

11.4.d.

The lavatory is inaccessible because the bottom edge of the apron is 27½ inches high.

TR11

12 months

11.4.e.

The side grab bar at the designated accessible toilet is inaccessible because it is obstructed by the toilet paper dispenser.

ST8

12 months

11.4.f.

Although there are 8 toilet stalls, there is no ambulatory stall provided.

ST1

12 months

11.5.

MenÕs Toilet Room in Lobby

   

11.5.a.

The door is inaccessible because it requires 13 pounds of force to open.

D2

12 months

11.5.b.

The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact.

TR12

12 months

11.5.c.

The lavatory is inaccessible because the bottom edge of the apron is 27½ inches high.

TR11

12 months

11.5.d.

The urinal is inaccessible because the rim is 18 inches above the finished floor.

TR20

12 months

11.5.e.

The side grab bar at the designated accessible toilet is inaccessible because it is obstructed by the toilet paper dispenser.

ST8

12 months

11.5.f.

Although there are 7 toilet stalls, no ambulatory stall is provided.

ST1

12 months

11.6.

Drinking Fountains near MenÕs and WomenÕs Toilet Rooms and Gymnasium

   

11.6.a.

The drinking fountains are inaccessible because the flow of water is between 1 and 3 inches high.

DF7

12 months

11.6.b.

Although designated accessible drinking fountains are provided, there is no drinking fountain provided for people who have difficulty bending or stooping.

DF3

12 months

11.7.

Snack Bar

   

11.7.a.

The counter is inaccessible because it is 37 inches above the finished floor.

C5

12 months

11.7.b.

The dining area is inaccessible because the tables do not provide the required knee space.

PD3

12 months

11.8.

Interior Doors: The doors to the ice rink and the gymnasium are inaccessible because they require 10 to 12 pounds of force to open.

D2

12 months

11.9.

MenÕs and WomenÕs Locker Rooms off Gymnasium

   

11.9.a.

The toilet room signs are not mounted on the latch sides of the doors and have no raised or Braille characters.

TR18

12 months

11.9.b.

No accessible mirror has been provided in any of the locker rooms.

TR14

12 months

11.9.c.

The lavatories are inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact.

TR12

12 months

11.9.d.

The urinals are inaccessible because the rims are 25 inches above the finished floor.

TR20

12 months

11.9.e.

The side grab bar at each designated accessible toilet is inaccessible because it is obstructed by the toilet paper dispenser.

ST8

12 months

11.9.f.

There is no accessible shower provided in any of the locker rooms.

B8

12 months

11.9.g.

No accessible towel hook has been provided in any of the locker rooms.

TR1

12 months

11.9.h.

The bench is inaccessible because it is less than 24 inches deep and it is not fixed to the wall.

LR1

12 months

12.

Sanctuary Skate Park - 2279 Grand Avenue

   

12.1.

Main Entrance

   

12.1.a.

The door is inaccessible because there is a ½ inch high unbeveled threshold.

D22

12 months

12.1.b.

The door is inaccessible because there is a slope of more than 2% within the doorÕs required maneuvering clearance.

D13

12 months

12.2.

Exit to Skate Park

   

12.2.a.

The door is inaccessible because there is a ½ inch high unbeveled threshold.

D22

12 months

12.2.b.

The door is inaccessible because there is a slope of more than 2% within the doorÕs required maneuvering clearance.

D13

12 months

12.3.

Snack Bar: The counter is inaccessible because it is 40 inches above the finished floor.

C5

12 months

12.4.

AED by Exit: The AED protrudes into the walkway and is not detectable to blind persons using a cane.

AR8

12 months

12.5.

Exterior Drinking Fountain: The drinking fountain is inaccessible because the spout is 44 inches above the finished floor, the control is mounted on the top of the fountain and requires 7 pounds of force to operate, and there is insufficient clear knee space provided.

DF1

12 months

12.6.

Exterior MenÕs Toilet Room

   

12.6.a.

The toilet room sign is mounted on the door.

TR18

12 months

12.6.b.

The push side of the door, which is accessed from the hinge side of the door, is inaccessible because it has 38 inches of clear depth.

D9

12 months

12.6.c.

No accessible mirror has been provided.

TR14

12 months

12.6.d.

The air dryers protrudes into the walkway and are not detectable to blind persons using a cane.

AR8

12 months

12.6.e.

The lavatories are inaccessible because the bottom edge of the apron of the lavatory outside the stall is 27¼ is inches above the finished floor and the top of the rim of the lavatory inside the stall is 34½ inches above the finished floor.

TR11

12 months

12.6.f.

The designated accessible toilet is inaccessible because its centerline is 19 inches from the side wall.

ST17

12 months

12.6.g.

The side grab bar at the designated accessible toilet is inaccessible because it is obstructed by the toilet paper dispenser.

ST8

12 months

12.6.h.

The side grab bar at the designated accessible toilet is inaccessible because it is mounted with the far end 48 inches from the rear wall.

ST6

12 months

12.7.

Exterior WomenÕs Toilet Room

   

12.7.a.

The toilet room sign is mounted on the door.

TR18

12 months

12.7.b.

The pull side of the door, which is accessed through a front approach, is inaccessible because it has 7 inches of clear space on the latch side.

D6

12 months

12.7.c.

No accessible mirror has been provided.

TR14

12 months

12.7.d.

The air dryers protrude into the walkway and are not detectable to blind persons using a cane.

AR8

12 months

12.7.e.

The designated accessible toilet is inaccessible because its centerline is 20 inches from the side wall.

ST17

12 months

12.7.f.

The designated accessible toilet is inaccessible because the flush control is on the closed side.

ST2

12 months

12.7.g.

The toilet paper dispenser in the designated accessible stall is inaccessible because it is mounted 39 inches from the rear wall.

ST19

12 months

12.7.h.

The side grab bar at the designated accessible toilet is inaccessible because it is mounted with the far end 47 inches from the rear wall.

ST7

12 months

12.7.i.

The rear grab bar at the designated accessible toilet is inaccessible because it is 24 inches long and it is mounted 6½ inches from the side wall.

ST4

12 months

13.

Eastwood Country Club - 4600 Bruce Herd Lane

   

13.1.

Parking: The parking lot, with a total of 230 parking spaces, is inaccessible because it only has 6 spaces designated as accessible, and 3 of the designated accessible spaces have slopes between 2.6% and 3%. This lot requires 1 van accessible space and 6 standard accessible spaces or 7 universal design spaces.

P3

12 months

13.2.

Club House Lobby

   

13.2.a.

The lower drinking fountain is inaccessible because the controls require 7 pounds of force to operate.

DF2

12 months

13.2.b.

The higher drinking fountain protrudes into the walkway and is not detectable to blind persons using a cane.

AR8

12 months

13.3.

Club House Lobby MenÕs Toilet Room

   

13.3.a.

The door is inaccessible because it requires 17 pounds of force to open.

D2

12 months

13.3.b.

The pull side of the door, which is accessed through a front approach, is inaccessible because the clear floor space is obstructed by a chair.

D6

12 months

13.4.

Club House Lobby WomenÕs Toilet Room

   

13.4.a.

The door is inaccessible because it requires 16 pounds of force to open.

D2

12 months

13.4.b.

The pull side of the door, which is accessed through a front approach, is inaccessible because the clear floor space is obstructed by a chair.

D6

12 months

13.5.

Clubroom Snack Bar: The counter protrudes into the walkway and is not detectable to blind persons using a cane.

AR8

12 months

13.6.

Pro Shop

   

13.6.a.

The benches in the 2 unisex dressing rooms are inaccessible because they are 17 inches deep, 42 inches long, and not fixed to the wall.

LR1

12 months

13.6.b.

No accessible clothes rod has been provided.

TR1

12 months

13.7.

Gazebo

   

13.7.a.

The snack bar counter protrudes into the walkway and is not detectable to blind persons using a cane.

AR8

12 months

13.7.b.

Although a designated accessible drinking fountain is provided, there is no drinking fountain provided for people who have difficulty bending or stooping.

DF3

12 months

13.7.c.

The drinking fountain protrudes into the walkway and is not detectable to blind persons using a cane.

AR8

12 months

13.8.

Top 9 and Back 9 Toilet Rooms (Existing): The menÕs and womenÕs toilet rooms contain a number of inaccessible elements and are not accessible to people with disabilities.

TR22

12 months

13.9.

StartersÕ Booth (Existing): The service window is inaccessible because it is 48 inches above the finished floor.

C5

12 months

13.10.

Golf Carts: Although there are golf carts for public use at this facility, none are accessible to persons who use wheelchairs.

G1

12 months

14.

Trailhead Park - 3600 Veronica Shoemaker Drive

   

14.1.

WomenÕs Single User Toilet Room

   

14.1.a.

The toilet paper dispenser in the designated accessible stall is inaccessible because it is mounted 18 inches above the finished floor.

SU17

12 months

14.1.b.

The rear grab bar at the toilet is inaccessible because it is obstructed by the toilet flush valve.

SU4

12 months

14.2.

MenÕs Single User Toilet Room

   

14.2.a.

The toilet paper dispenser in the designated accessible stall is inaccessible because it is mounted 18 inches above the finished floor.

SU17

12 months

14.2.b.

The rear grab bar at the toilet is inaccessible because it is obstructed by the toilet flush valve.

SU4

12 months

14.3.

Pavilion #1

   

14.3.a.

The drinking fountain is inaccessible because the flow of water is 3 inches high.

DF7

12 months

14.3.b.

The drinking fountains protrude into the walkway and are not detectable to blind persons using a cane.

AR8

12 months

14.4.

Pavilions 3 & 4: The route to the grill is inaccessible because the grass is not firm, stable, and slip resistant.

AR1

12 months

15.

Riverside Park and Community Center

   

15.1.

Community Center Entrance Ramp: The ramp is inaccessible because the top landing is 56 inches long.

R5

12 months

15.2.

Lobby MenÕs Toilet Room

   

15.2.a.

The door is inaccessible because it requires 7 pounds of force to open.

D2

12 months

15.2.b.

No accessible mirror has been provided.

TR14

12 months

15.2.c.

The side grab bar at the designated accessible toilet is inaccessible because it is obstructed by the toilet paper dispenser.

ST8

12 months

15.3.

Lobby WomenÕs Toilet Room

   

15.3.a.

The door is inaccessible because it requires 12 pounds of force to open.

D2

12 months

15.3.b.

The side grab bar at the designated accessible toilet is inaccessible because it is obstructed by the toilet paper dispenser.

ST8

12 months

15.4.

Drinking Fountain by Toilet Rooms: The drinking fountain is inaccessible because the flow of water is 2 inches high.

Df7

12 months

15.5.

Wood Shop: The door is inaccessible because it requires 11 pounds of force to open

D2

12 months

15.6.

Classroom: The door is inaccessible because it requires 12 pounds of force to open.

D2

12 months

15.7.

North Exit Door Off Main Corridor: The door is inaccessible because there is a 1½ inch high threshold.

D22

12 months

15.8.

Anderson Hall

   

15.8.a.

The double doors are inaccessible because they require 20 pounds of force to open.

D2

12 months

15.8.b.

The ramp to the stage is inaccessible because it has a slope of up to 9.4%, the handrails are mounted 1¾ inches from the wall, and the top landing is 50 inches long.

R3

12 months

15.9.

Ceramic Shop: The door is inaccessible because it requires 12 pounds of force to open.

D2

12 months

15.10.

Kitchen

   

15.10.a. 

 

The door is inaccessible because it requires 9 pounds of force to open.

D2

12 months

15.10.b. 

 

The hand-washing sink is inaccessible because the knee space is obstructed by the stopper lever and the hot water pipes are not insulated or otherwise configured to protect against contact.

S2

12 months

15.10.c. 

 

The exit door is inaccessible because there is a 1¾ inch high threshold.

D22

12 months

15.10.d. 

 

The pull side of the exit door is inaccessible because it has only 14½ inches of clear space on the latch side.

D8, D9, D10

12 months

15.11.

Exit Door from Corridor to Porch: The door is inaccessible because there is a 1¾ inch high threshold.

D22

12 months

15.12.

Exit Door from Corridor South Side: The door is inaccessible because there is a 1¾ inch high threshold.

D22

12 months

15.13.

Park

   

15.13.a. 

 

The toilet room sign at the designated accessible portable toilet is mounted on the door and has no raised or Braille characters.

TR18

12 months

15.13.b. 

 

The side grab bar at the designated accessible portable toilet is inaccessible because it is obstructed by the toilet paper dispenser.

SU7

12 months

15.13.c. 

 

The designated accessible portable toilet is inaccessible because it provides insufficient clear floor space at the toilet.

SU16

12 months

15.13.d. 

 

The routes to the grills near each pavilion are inaccessible because the grass is not firm, stable, and slip resistant.

AR1

12 months

15.13.e. 

 

The picnic tables at each pavilion are inaccessible because none provide the required knee space.

PD6

12 months

15.13.f. 

 

The drinking fountain near the play area is inaccessible because it requires 13 pounds of force to operate.

DF2

12 months

15.13.g. 

 

The drinking fountain near the play area is inaccessible because the clear floor space has a slope of 7.1%.

DF5

12 months

15.14.

Fixed Pier: The route to the fixed pier is inaccessible because there is a 1½ inch change in the level on the sidewalk.

AR1

12 months


 