ATTACHMENT I: Modifications to Newly Constructed Facilities Please Note: Paragraph 44 of the Settlement Agreement requires that within three months of the effective date of this Agreement, the City provide signage as necessary to comply with 28 C.F.R. § 35.163(b), after having surveyed all facilities that are the subject of this Agreement for the purpose of identifying those that have multiple entrances not all of which are accessible. The chart below lists the facilities surveyed by the Department, the access issues identified during the survey, and the actions required to correct the access issues. Required actions are listed using an alphanumeric code. The key to the alphanumeric codes is provided in Attachment M to this Agreement. In order to ensure that the following spaces and elements in City facilities for which construction was commenced after January 26, 1992, are readily accessible to and usable by persons with disabilities, the City will take the actions referenced by the alphanumeric code and described in detail in Attachment M to this Settlement Agreement within the time periods specified below, which time periods will begin to run on the effective date of this Agreement. |
|||
item # |
Access Issue |
Required Action |
Completion Date |
---|---|---|---|
1. |
Business Development Center - 3901 Dr. Martin Luther King Boulevard |
||
1.1. |
Main Reception Area Single User Unisex Toilet Room on the Righ |
||
1.1.a. |
The door is inaccessible because it requires 7 pounds of force to open. |
D2 |
12 months |
1.1.b. |
The side grab bar at the toilet is inaccessible because it is obstructed by the toilet paper dispenser. |
SU7 |
12 months |
1.2. |
Main Reception Area Single User Unisex Toilet Room on the Left |
||
1.2.a. |
The door is inaccessible because it requires 6 pounds of force to open. |
D2 |
12 months |
1.2.b. |
The side grab bar at the toilet is inaccessible because it is obstructed by the toilet paper dispenser. |
SU7 |
12 months |
1.3. |
Exterior Single User Unisex Toilet Rooms |
||
1.3.a. |
The side grab bar at each toilet is inaccessible because it is obstructed by the toilet paper dispenser. |
SU7 |
12 months |
1.3.b. |
The toilet paper dispenser in 2 of the rooms is inaccessible because it is mounted 40 inches from the rear wall. |
SU17 |
12 months |
1.4. |
Picnic Tables between Exterior Unisex Toilet Rooms: The picnic tables are inaccessible because none provide the required knee space. |
PD6 |
12 months |
1.5. |
West Alcove Drinking Fountain: The drinking fountain is inaccessible because the controls require 7 pounds of force to operate. |
DF2 |
12 months |
1.6. |
East Alcove Drinking Fountain: The drinking fountain is inaccessible because the controls require 11 pounds of force to operate, and the flow of water is 3 inches high and 4 inches from the front of the fountain. |
DF1 |
12 months |
2. |
City Pier Building - 1300 Hendry Street |
||
2.1. |
Front Entrance |
||
2.1.a. |
The mailboxes in the vestibule protrude into the walkway and are not detectable to blind persons using a cane. |
AR8 |
12 months |
2.1.b. |
The alcove under the stairway in the vestibule is an overhead hazard. |
AR7 |
12 months |
2.1.c. |
The interior door is inaccessible because it requires 14 pounds of force to open. |
D2 |
12 months |
2.1.d. |
The entrance ramp is inaccessible because it has a slope of up to 9.9%, the handrails are not stable or continuous, one intermediate landing is 58½ inches wide, and the handrail is mounted 4¼ inches from the wall. |
R3 |
12 months |
2.2. |
1st Floor Drinking Fountain |
||
2.2.a. |
The drinking fountain is inaccessible because the controls require 7 pounds of force to operate. |
DF2 |
12 months |
2.2.b. |
The drinking fountain is inaccessible because the spout is 3½ inches from the front of the fountain. |
DF1 |
12 months |
2.2.c. |
Although a designated accessible drinking fountain is provided, there is no drinking fountain provided for people who have difficulty bending or stooping. |
DF3 |
12 months |
2.3. |
Single User Toilet Room in 1st Floor WomenÕs Toilet Room |
||
2.3.a. |
The door to the main toilet room is inaccessible because it requires 6 pounds of force to open. |
D2 |
12 months |
2.3.b. |
The pull side of the door to the single user toilet room, which is accessed through a front approach, is inaccessible because it has only 3 inches of clear space on the latch side. |
D6 |
12 months |
2.3.c. |
No accessible mirror has been provided. |
TR14 |
12 months |
2.3.d. |
The side grab bar at the toilet is inaccessible because it is mounted 32½ inches above the finished floor. |
SU11 |
12 months |
2.3.e. |
The rear grab bar at the toilet is inaccessible because it is obstructed by the toilet seat cover dispenser. |
SU4 |
12 months |
2.4. |
Single User Toilet Room in 1st Floor MenÕs Toilet Room |
||
2.4.a. |
No accessible mirror has been provided. |
TR14 |
12 months |
2.4.b. |
The toilet paper dispenser is inaccessible because it is mounted 44 inches from the rear wall. |
SU17 |
12 months |
2.4.c. |
The rear grab bar at the toilet is inaccessible because it is obstructed by the toilet seat cover dispenser. |
SU4 |
12 months |
2.5. |
Elevators |
||
2.5.a. |
The hall lanterns are inaccessible because the signals are not visible from the area of the hall call buttons. |
E11 |
12 months |
2.5.b. |
The elevator is inaccessible because the time between the doors reopening due to an obstruction and the doors closing is 2 seconds. |
E6 |
12 months |
2.5.c. |
The elevator is inaccessible because the emergency system requires voice communication to operate, and it requires tight grasping or pinching to access. |
E8 |
12 months |
2.6. |
2nd Floor Drinking Fountain |
||
2.6.a. |
The drinking fountain is inaccessible because the flow of water is 3½ inches from the front of the fountain. |
DF7 |
12 months |
2.6.b. |
Although a designated accessible drinking fountain is provided, there is no drinking fountain provided for people who have difficulty bending or stooping. |
DF3 |
12 months |
2.7. |
Single User Toilet Room in 2nd Floor WomenÕs Toilet Room |
||
2.7.a. |
The door to the main toilet room is inaccessible because it requires 8 pounds of force to open. |
D2 |
12 months |
2.7.b. |
The pull side of the door to the single user toilet room, which is accessed through a front approach, is inaccessible because it has less than 18 inches of clear space on the latch side. |
D6 |
12 months |
2.7.c. |
The toilet is inaccessible because its centerline is 18¾ inches from the side wall. |
SU15 |
12 months |
2.7.d. |
The toilet paper dispenser is inaccessible because it is mounted 43 inches from the rear wall. |
SU17 |
12 months |
2.7.e. |
The side grab bar at the toilet is inaccessible because it is mounted 12½ inches from the rear wall. |
SU6 |
12 months |
2.7.f. |
The rear grab bar at the toilet is inaccessible because it is obstructed by the seat cover dispenser and the soap dispenser. |
SU4 |
12 months |
2.8. |
Single User Toilet Room in 2nd Floor MenÕs Toilet Room |
||
2.8.a. |
The door is inaccessible because it requires 7 pounds of force to open. |
D2 |
12 months |
2.8.b. |
The lavatory is inaccessible because the bottom edge of the apron is 28½ inches above the finished floor. |
TR11 |
12 months |
2.8.c. |
The toilet paper dispenser is inaccessible because it is mounted 43 inches from the rear wall. |
SU17 |
12 months |
2.8.d. |
The rear grab bar at the toilet is inaccessible because it is obstructed by the seat cover dispenser and the soap dispenser. |
SU4 |
12 months |
3. |
Fire Station #4 - 4520 Cummins Court |
||
3.1. |
Parking: The designated accessible parking space at the back of the building is inaccessible because it has no access aisle. |
P5 |
12 months |
3.2. |
Entrances |
||
3.2.a. |
The ramp to the side entrance is inaccessible because it has no handrails, and the top landing is only 41½ inches deep. |
R5 |
12 months |
3.2.b. |
The pull side of the rear entrance door, which is accessed through a front approach, is inaccessible because it has insufficient clear space on the latch side and only 41½ inches of maneuvering depth. |
D6 |
12 months |
3.2.c. |
The entrance doors are inaccessible because knob hardware is used. |
D1 |
12 months |
3.2.d. |
The side entrance is blocked by equipment on the inside. |
AR3 |
12 months |
3.3. |
Interior Doors |
||
3.3.a. |
The interior doors throughout the facility are inaccessible because knob hardware is used. |
D1 |
12 months |
3.3.b. |
The interior doors throughout the facility are inaccessible because they require more than 5 pounds of force to open. |
D2 |
12 months |
3.4. |
Locker Rooms: The locker rooms contain a number of inaccessible elements and are not accessible to people with disabilities. |
LR4 |
12 months |
3.5. |
Drinking Fountain in Equipment Room |
||
3.5.a. |
The drinking fountain is inaccessible because the flow of water is 3½ inches from the front of the fountain. |
DF7 |
12 months |
3.5.b. |
Although a designated accessible drinking fountain is provided, there is no drinking fountain provided for people who have difficulty bending or stooping. |
DF3 |
12 months |
3.6. |
Single User Toilet Room by Equipment Room: The room contains a number of inaccessible elements and is not accessible to people with disabilities. |
SU13 |
12 months |
4. |
Sam Fleishman Regional Sports Complex - Baseball Fields - 1750 Matthew Drive |
|
|
4.1. |
Parking: Several of the curb ramps are inaccessible because they have slopes exceeding 8.33%. |
AR5 |
12 months |
4.2. |
John Nelson Stadium - Field #7: The baseball seating area is inaccessible because there is no ramp to access it, no companion seats are provided, and it is not integrated with the rest of the seating area. |
AA7 |
12 months |
4.3. |
Maintenance Facility Unisex Single User Toilet Room |
||
4.3.a. |
The toilet is inaccessible because the top of the seat is 16½ inches above the finished floor. |
SU18 |
12 months |
4.3.b. |
The toilet is inaccessible because a shelf obstructs the clear floor space. |
SU16 |
12 months |
4.3.c. |
The shelf protrudes into the walkway and is not detectable to blind persons using a cane. |
AR8 |
12 months |
4.3.d. |
The toilet paper dispenser is inaccessible because it is mounted more than 36 inches from the rear wall. |
SU17 |
12 months |
4.4. |
Press/Concession Building Lift |
||
4.4.a. |
The lift is inaccessible because the interior is only 46½ inches deep. |
LF2 |
12 months |
4.4.b. |
The lift is inaccessible because it requires that a key be obtained from an employee before the lift can be operated. |
LF1 |
12 months |
4.4.c. |
The lift is inaccessible because it is being used for storage. |
M2 |
12 months |
4.5. |
Snack Bar in Press Box Building |
||
4.5.a. |
The kitchen sink is inaccessible because the hot water and drain pipes are not insulated or otherwise configured to protect against contact. |
S2 |
12 months |
4.5.b. |
Although a designated accessible drinking fountain is provided, there is no drinking fountain provided for people who have difficulty bending or stooping. |
DF3 |
12 months |
4.6. |
Picnic Tables: The picnic tables throughout the facility are inaccessible because none provide the required knee space. |
PD6 |
12 months |
4.7. |
WomenÕs Single User Toilet Room in Press/Concession Building |
||
4.7.a. |
The toilet room sign is inaccessible because it is mounted 65½ inches above the finished floor. |
TR18 |
12 months |
4.7.b. |
The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact. |
TR12 |
12 months |
4.7.c. |
The toilet is inaccessible because the top of the seat is 16 inches above the finished floor. |
SU18 |
12 months |
4.7.d. |
The toilet is inaccessible because there are no grab bars provided. |
SU10 |
12 months |
4.8. |
MenÕs Single User Toilet Room in Press/Concession Building |
||
4.8.a. |
The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact. |
TR12 |
12 months |
4.8.b. |
The urinal is inaccessible because the rim is 24¼ inches above the finished floor and the flush control is 51 inches above the finished floor. |
TR20 |
12 months |
4.8.c. |
The toilet is inaccessible because the top of the seat is 16 inches above the finished floor. |
SU18 |
12 months |
4.8.d. |
The toilet is inaccessible because the flush control is on the closed side. |
SU1 |
12 months |
4.8.e. |
The toilet is inaccessible because its centerline is 19½ inches from the side wall. |
SU15 |
12 months |
4.8.f. |
The toilet is inaccessible because there are no grab bars provided. |
SU10 |
12 months |
4.8.g. |
The toilet is inaccessible because the urinal obstructs the clear floor space. |
SU16 |
12 months |
4.9. |
Ballfields |
||
4.9.a. |
Some of the dugouts are inaccessible because they can be accessed only by steps. |
AR1 |
12 months |
4.9.b. |
Many of the fields are inaccessible because the routes to them are not firm, stable, and slip resistant. |
AR1 |
12 months |
4.9.c. |
The batting cages are inaccessible because the route is not firm, stable, and slip resistant. |
AR1 |
12 months |
5. |
Sam Fleishman Regional Sports Complex - Aquatic Center - 1750 Matthew Drive |
|
|
5.1. |
Parking: The parking lot, with a total of 78 parking spaces, is inaccessible because it only has 1 space designated as accessible. This lot requires 1 van accessible space and 4 standard accessible spaces. |
P3 |
12 months |
5.2. |
Route to Entrance |
||
5.2.a. |
The curb ramp by the facility entrance is inaccessible because it has a slope of 11% and the side flares have slopes of 19.5 % and 15.3%. |
AR5 |
12 months |
5.2.b. |
The curb ramp in front of the designated accessible parking space is inaccessible because it has a slope of 10.1%. |
AR5 |
12 months |
5.3. |
Entrance Counter: The counter is inaccessible because it is 42 inches above the finished floor. |
C6 |
12 months |
5.4. |
Drinking Fountain: Although a designated accessible drinking fountain is provided, there is no drinking fountain provided for people who have difficulty bending or stooping. |
DF3 |
12 months |
5.5. |
Kiddie Pool |
||
5.5.a. |
The counter is inaccessible because it is 42 inches above the finished floor. |
C6 |
12 months |
5.5.b. |
The operating mechanism for the gate between the kiddie pool and the lap lanes is inaccessible because it is mounted 60 inches above the finished floor. |
D1 |
12 months |
5.6. |
Snack Bar: The counter is inaccessible because it is 42 inches above the finished floor. |
C5 |
12 months |
5.7. |
MenÕs Locker Room |
||
5.7.a. |
The lavatory is inaccessible because the bottom edge of the apron is 28 inches above the finished floor. |
TR11 |
12 months |
5.7.b. |
The designated accessible toilet is inaccessible because the flush control is on the closed side. |
ST2 |
12 months |
5.7.c. |
The side grab bar at the designated accessible toilet is inaccessible because it is obstructed by the toilet paper dispenser. |
ST8 |
12 months |
5.7.d. |
The side grab bar at the designated accessible toilet is inaccessible because it is mounted 12½ inches from the rear wall. |
ST7 |
12 months |
5.7.e. |
The rear grab bar at the designated accessible toilet is inaccessible because it is mounted 12 inches from the side wall. |
ST4 |
12 months |
5.7.f. |
The designated accessible toilet is inaccessible because the rear grab bar is obstructed by the paper towel dispenser. |
ST5 |
12 months |
5.7.g. |
The designated accessible roll-in shower is inaccessible because the clear floor space at the entry is less than 60 inches wide, there is no handheld shower spray unit, the fixed shower head is mounted approximately 72 inches above the finished floor, and the floor slopes 8.9%. |
B8 |
12 months |
5.7.h. |
No accessible towel or clothes hooks have been provided. |
TR1 |
12 months |
5.7.i. |
The bench is inaccessible because it is 9 inches deep. |
LR1 |
12 months |
5.8. |
WomenÕs Locker Room |
||
5.8.a. |
The side grab bar at the designated accessible toilet is inaccessible because it is obstructed by the toilet paper dispenser and the trash receptacle. |
ST8 |
12 months |
5.8.b. |
The side grab bar at the designated accessible toilet is inaccessible because it is mounted 13 inches from the rear wall. |
ST7 |
12 months |
5.8.c. |
The rear grab bar at the designated accessible toilet is inaccessible because it is mounted 12 inches from the side wall. |
ST4 |
12 months |
5.8.d. |
The designated accessible toilet is inaccessible because the rear grab bar is obstructed by the paper towel dispenser. |
ST5 |
12 months |
5.8.e. |
The ambulatory stall is inaccessible because the partitions are 37 inches apart; the toilet seat is 20¼ inches above the finished floor; one grab bar is mounted 12½ inches from the rear wall; and the toilet paper dispenser interferes with the use of the grab bar. |
ST1 |
12 months |
5.8.f. |
The designated accessible roll-in shower is inaccessible because it is 58 inches wide, the clear floor space at the entry is less than 60 inches wide, there is no handheld shower spray unit, the fixed shower head is mounted approximately 72 inches above the finished floor, and the floor slopes 8.9%. |
B8 |
12 months |
5.8.g. |
The bench is inaccessible because it is 9 inches deep and 16½ inches above the finished floor. |
LR1 |
12 months |
6. |
Sam Fleishman Regional Sports Complex - Racquet Club - 1750 Matthew Drive |
|
|
6.1. |
Parking: The parking is inaccessible because 3 of the designated accessible parking spaces have slopes between 3.1% and 4.7%. |
P7 |
12 months |
6.2. |
Entrance: There is a slope of 5.9% near the entrance with no ramp features provided. |
R4 |
12 months |
6.3. |
MenÕs Single User Toilet and Shower Room |
||
6.3.a. |
The toilet room sign is mounted on the door. |
TR18 |
12 months |
6.3.b. |
Although an audible alarm is provided in this facility, there is no visual alarm appliance in the toilet room. |
TR21 |
12 months |
6.3.c. |
The bench narrows the path of travel to 28 inches wide. |
AR3 |
12 months |
6.3.d. |
No accessible towel hook has been provided. |
TR1 |
12 months |
6.4. |
WomenÕs Single User Toilet and Shower Room |
||
6.4.a. |
The toilet room sign is mounted on the door. |
TR18 |
12 months |
6.4.b. |
Although an audible alarm is provided in this facility, there is no visual alarm appliance in the toilet room. |
TR21 |
12 months |
6.4.c. |
The paper towel dispenser protrudes into the walkway and is not detectable to blind persons using a cane. |
AR8 |
12 months |
6.4.d. |
The bench narrows the path of travel to 28 inches wide. |
AR3 |
12 months |
6.4.e. |
No accessible towel hook has been provided. |
TR1 |
12 months |
6.5. |
Picnic Tables: The picnic tables are inaccessible because none provide the required knee space. |
PD6 |
12 months |
6.6. |
Exterior Route: The AED protrudes into the walkway and is not detectable to blind persons using a cane. |
AR8 |
12 months |
6.7. |
Racquet Club Store |
||
6.7.a. |
The counter is inaccessible because it is 38 inches above the finished floor. |
C5 |
12 months |
6.7.b. |
The route is inaccessible because it is obstructed with merchandise. |
AR3 |
12 months |
7. |
Sam Fleishman Regional Sports Complex - Park, Carner Field- 1750 Matthew Drive |
|
|
7.1. |
Exterior Routes: The routes to the benches, swing areas, and grills are inaccessible because the surfaces are not firm, stable, and slip resistant. |
AR1 |
12 months |
7.2. |
Carner Field: The dugouts are inaccessible because there are steps to access them. |
AR1 |
12 months |
7.3. |
Drinking Fountains near Picnic and Play Areas |
||
7.3.a. |
The drinking fountains are inaccessible because the flow of water is 7 inches from the fronts of the fountains. |
DF7 |
12 months |
7.3.b. |
Although designated accessible drinking fountains are provided, there is no drinking fountain provided for people who have difficulty bending or stooping. |
DF3 |
12 months |
7.3.c. |
The drinking fountains protrude into the walkway and are not detectable to blind persons using a cane. |
AR8 |
12 months |
8. |
City of Fort Myers Utilities Billing Center - 2925 Martin Luther King, Jr., Boulevard |
||
8.1. |
Parking: The designated accessible parking spaces and access aisle are inaccessible because they have slopes between 2.5% and 3.4%. |
P7 |
12 months |
8.2. |
Interior Doors: The interior doors throughout the facility are inaccessible because they require more than 5 pounds of force to open. |
D2 |
12 months |
8.3. |
Lobby Drinking Fountain: Although a designated accessible drinking fountain is provided, there is no drinking fountain provided for people who have difficulty bending or stooping. |
DF3 |
12 months |
8.4. |
Lobby Unisex Single User Toilet Room |
||
8.4.a. |
The toilet room sign is mounted 62 inches above the finished floor. |
TR18 |
12 months |
8.4.b. |
The pull side of the door, which is accessed through a front approach, is inaccessible because it has 9 inches of clear space on the latch side. |
D6 |
12 months |
8.4.c. |
The toilet is inaccessible because the flush control is on the closed side. |
SU1 |
12 months |
8.5. |
Employee Area MenÕs Single User Toilet Room |
||
8.5.a. |
The toilet is inaccessible because the flush control is on the closed side. |
SU1 |
12 months |
8.5.b. |
The toilet is inaccessible because there are no grab bars provided. |
SU10 |
12 months |
8.6. |
Customer Service/Cashier Service: The mail slot is inaccessible because it is 62 inches above the finished floor. |
TR5 |
12 months |
9. |
Fowler Street |
||
9.1. |
Gutter Slopes: The curb ramps along Fowler Street generally are inaccessible because they have gutter slopes exceeding 5%. |
AR5 |
12 months |
9.2. |
East Side of Fowler Street between Simpson and Welch Streets: The route across the gas station driveway is inaccessible because it slopes up to 9.4% on the south side. |
AR1 |
12 months |
9.3. |
East Side of Fowler Street at Welch Street |
||
9.3.a. |
The curb ramp on the southeast corner is inaccessible because it has a slope of 9%. |
AR5 |
12 months |
9.3.b. |
The curb ramp on the northeast corner is inaccessible because it has a slope of 9.2%. |
AR5 |
12 months |
9.4. |
East Side of Fowler Street at Hunter Terrace |
||
9.4.a. |
The curb ramp on the southeast corner is inaccessible because it has a cross slope of 4.1%. |
AR5 |
12 months |
9.4.b. |
The curb ramp on the northeast corner is inaccessible because it has a cross slope of 7%. |
AR5 |
12 months |
9.5. |
East Side of Fowler Street at Hunter Street |
||
9.5.a. |
The curb ramp on the southeast corner is inaccessible because it has a slope of 9% and a cross slope of 5.7%. |
AR5 |
12 months |
9.5.b. |
The curb ramp on the northeast corner is inaccessible because it has a cross slope of 3.1%. |
AR5 |
12 months |
9.6. |
East Side of Fowler Street at Parkway Street |
||
9.6.a. |
The curb ramp on the southeast corner is inaccessible because it has a cross slope of 4.9%. |
AR5 |
12 months |
9.6.b. |
The curb ramp on the northeast corner is inaccessible because it has a cross slope of 6% . |
AR5 |
12 months |
9.7. |
East Side of Fowler Street between Parkway and Kennesaw Streets: The route near 3333 Fowler is inaccessible because is has a cross slope of up to 4.8% and tree roots create steps in the pavement 1¼ inches high. |
AR1 |
12 months |
9.8. |
East Side of Fowler Street at Kennesaw Street: The curb ramp on the southeast corner is inaccessible because it has a cross slope of 6.6%. |
AR5 |
12 months |
9.9. |
East Side of Fowler Street between Kennesaw and Collins Streets: The route near 3253 Fowler Street is inaccessible because tree roots create unbeveled changes in level in excess of ½ inch high. |
AR1 |
12 months |
9.10. |
East Side of Fowler Street at Collins Street |
||
9.10.a. |
The curb ramp on the southeast corner is inaccessible because it has a slope of 9.1% and a cross slope of 4.7%. |
AR5 |
12 months |
9.10.b. |
The curb ramp on the northeast corner is inaccessible because it has a slope of 8.7% and a cross slope of 10.4% . |
AR5 |
12 months |
9.11. |
East Side of Fowler Street between Collins and Moreno Streets: The route near 3237 Fowler Street is inaccessible because it has a number of changes in level between 1 inch and 1¾ inches high. |
AR1 |
12 months |
9.12. |
East Side of Fowler Street at Moreno Street: The curb ramp on the southeast corner is inaccessible because it has a cross slope of 7.1%. |
AR5 |
12 months |
9.13. |
West Side of Fowler Street at Moreno Street |
||
9.13.a. |
The curb ramp on the northwest corner is inaccessible because it has a cross slope of 6.4%. |
AR5 |
12 months |
9.13.b. |
The curb ramp on the southwest corner is inaccessible because it has a cross slope of 8.1% . |
AR5 |
12 months |
9.14. |
West Side of Fowler Street between Moreno and Kennesaw Streets: The route near 3238 Fowler Street is inaccessible because it has several changes in level between 1 inch and 1¼ inches high. |
AR1 |
12 months |
9.15. |
West Side of Fowler Street at Kennesaw Street |
||
9.15.a. |
The curb ramp on the northwest corner is inaccessible because it has a cross slope of 5.4%. |
AR5 |
12 months |
9.15.b. |
The curb ramp on the southwest corner is inaccessible because it has a cross slope of 7.8% . |
AR5 |
12 months |
9.16. |
West Side of Fowler Street at Parkway Street |
||
9.16.a. |
The curb ramp on the northwest corner is inaccessible because it has a cross slope of 4.2%. |
AR5 |
12 months |
9.16.b. |
The curb ramp on the southwest corner is inaccessible because it has a cross slope of 6.2% . |
AR5 |
12 months |
9.17. |
West Side of Fowler Street at Hunter Street |
||
9.17.a. |
The curb ramp on the northwest corner is inaccessible because it has a cross slope of 6.9%. |
AR5 |
12 months |
9.17.b. |
The curb ramp on the southwest corner is inaccessible because it has a cross slope of 9.1%. |
AR5 |
12 months |
9.18. |
West Side of Fowler Street at Hunter Terrace |
||
9.18.a. |
The curb ramp on the northwest corner is inaccessible because it has a cross slope of 6.8%. |
AR5 |
12 months |
9.18.b. |
The curb ramp on the southwest corner is inaccessible because it has a cross slope of 9.9% . |
AR5 |
12 months |
9.19. |
West Side of Fowler Street at Welch Street |
||
9.19.a. |
The curb ramp on the northwest corner is inaccessible because it has a cross slope of 6.6%. |
AR5 |
12 months |
9.19.b. |
The curb ramp on the southwest corner is inaccessible because it has a cross slope of 4.3% . |
AR5 |
12 months |
9.20. |
West Side of Fowler Street at Simpson Street: The curb ramp on the southwest corner is inaccessible because it has a cross slope of 11.5% . |
AR5 |
12 months |
10. |
Tarpon Street Pier - Tarpon Street and Riverside Drive |
||
10.1. |
Canoe Path: The route to the canoe dump area is inaccessible because it is not firm, stable, and slip resistant. |
AR1 |
12 months |
11. |
Skatium- 2250 Broadway |
||
11.1. |
Route from Parking to Entrance |
||
11.1.a. |
The curb ramps on each side of Crawford Street side are inaccessible because they have gutter slopes of 10.1% and 8.9%. |
AR5 |
12 months |
11.1.b. |
The route along Broadway in front of the parking lot is inaccessible because there is a change in level ¾ inch high between two pavers. |
AR1 |
12 months |
11.2. |
Lobby |
||
11.2.a. |
The skate rental counter protrudes into the walkway and is not detectable to blind persons using a cane. |
AR8 |
12 months |
11.2.b. |
The AED protrudes into the walkway and is not detectable to blind persons using a cane. |
AR8 |
12 months |
11.3. |
Alarms: Although the facility contains an emergency alarm system, the alarm system is inaccessible because there are no visual alarms provided in toilet rooms, locker rooms, corridors, and hallways. |
AL1 |
12 months |
11.4. |
Lobby WomenÕs Toilet Room |
||
11.4.a. |
The sign is not mounted on the latch side of the door. |
TR18 |
12 months |
11.4.b. |
The door is inaccessible because it requires 9 pounds of force to open. |
D2 |
12 months |
11.4.c. |
The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact. |
TR12 |
12 months |
11.4.d. |
The lavatory is inaccessible because the bottom edge of the apron is 27½ inches high. |
TR11 |
12 months |
11.4.e. |
The side grab bar at the designated accessible toilet is inaccessible because it is obstructed by the toilet paper dispenser. |
ST8 |
12 months |
11.4.f. |
Although there are 8 toilet stalls, there is no ambulatory stall provided. |
ST1 |
12 months |
11.5. |
MenÕs Toilet Room in Lobby |
||
11.5.a. |
The door is inaccessible because it requires 13 pounds of force to open. |
D2 |
12 months |
11.5.b. |
The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact. |
TR12 |
12 months |
11.5.c. |
The lavatory is inaccessible because the bottom edge of the apron is 27½ inches high. |
TR11 |
12 months |
11.5.d. |
The urinal is inaccessible because the rim is 18 inches above the finished floor. |
TR20 |
12 months |
11.5.e. |
The side grab bar at the designated accessible toilet is inaccessible because it is obstructed by the toilet paper dispenser. |
ST8 |
12 months |
11.5.f. |
Although there are 7 toilet stalls, no ambulatory stall is provided. |
ST1 |
12 months |
11.6. |
Drinking Fountains near MenÕs and WomenÕs Toilet Rooms and Gymnasium |
||
11.6.a. |
The drinking fountains are inaccessible because the flow of water is between 1 and 3 inches high. |
DF7 |
12 months |
11.6.b. |
Although designated accessible drinking fountains are provided, there is no drinking fountain provided for people who have difficulty bending or stooping. |
DF3 |
12 months |
11.7. |
Snack Bar |
||
11.7.a. |
The counter is inaccessible because it is 37 inches above the finished floor. |
C5 |
12 months |
11.7.b. |
The dining area is inaccessible because the tables do not provide the required knee space. |
PD3 |
12 months |
11.8. |
Interior Doors: The doors to the ice rink and the gymnasium are inaccessible because they require 10 to 12 pounds of force to open. |
D2 |
12 months |
11.9. |
MenÕs and WomenÕs Locker Rooms off Gymnasium |
||
11.9.a. |
The toilet room signs are not mounted on the latch sides of the doors and have no raised or Braille characters. |
TR18 |
12 months |
11.9.b. |
No accessible mirror has been provided in any of the locker rooms. |
TR14 |
12 months |
11.9.c. |
The lavatories are inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact. |
TR12 |
12 months |
11.9.d. |
The urinals are inaccessible because the rims are 25 inches above the finished floor. |
TR20 |
12 months |
11.9.e. |
The side grab bar at each designated accessible toilet is inaccessible because it is obstructed by the toilet paper dispenser. |
ST8 |
12 months |
11.9.f. |
There is no accessible shower provided in any of the locker rooms. |
B8 |
12 months |
11.9.g. |
No accessible towel hook has been provided in any of the locker rooms. |
TR1 |
12 months |
11.9.h. |
The bench is inaccessible because it is less than 24 inches deep and it is not fixed to the wall. |
LR1 |
12 months |
12. |
Sanctuary Skate Park - 2279 Grand Avenue |
||
12.1. |
Main Entrance |
||
12.1.a. |
The door is inaccessible because there is a ½ inch high unbeveled threshold. |
D22 |
12 months |
12.1.b. |
The door is inaccessible because there is a slope of more than 2% within the doorÕs required maneuvering clearance. |
D13 |
12 months |
12.2. |
Exit to Skate Park |
||
12.2.a. |
The door is inaccessible because there is a ½ inch high unbeveled threshold. |
D22 |
12 months |
12.2.b. |
The door is inaccessible because there is a slope of more than 2% within the doorÕs required maneuvering clearance. |
D13 |
12 months |
12.3. |
Snack Bar: The counter is inaccessible because it is 40 inches above the finished floor. |
C5 |
12 months |
12.4. |
AED by Exit: The AED protrudes into the walkway and is not detectable to blind persons using a cane. |
AR8 |
12 months |
12.5. |
Exterior Drinking Fountain: The drinking fountain is inaccessible because the spout is 44 inches above the finished floor, the control is mounted on the top of the fountain and requires 7 pounds of force to operate, and there is insufficient clear knee space provided. |
DF1 |
12 months |
12.6. |
Exterior MenÕs Toilet Room |
||
12.6.a. |
The toilet room sign is mounted on the door. |
TR18 |
12 months |
12.6.b. |
The push side of the door, which is accessed from the hinge side of the door, is inaccessible because it has 38 inches of clear depth. |
D9 |
12 months |
12.6.c. |
No accessible mirror has been provided. |
TR14 |
12 months |
12.6.d. |
The air dryers protrudes into the walkway and are not detectable to blind persons using a cane. |
AR8 |
12 months |
12.6.e. |
The lavatories are inaccessible because the bottom edge of the apron of the lavatory outside the stall is 27¼ is inches above the finished floor and the top of the rim of the lavatory inside the stall is 34½ inches above the finished floor. |
TR11 |
12 months |
12.6.f. |
The designated accessible toilet is inaccessible because its centerline is 19 inches from the side wall. |
ST17 |
12 months |
12.6.g. |
The side grab bar at the designated accessible toilet is inaccessible because it is obstructed by the toilet paper dispenser. |
ST8 |
12 months |
12.6.h. |
The side grab bar at the designated accessible toilet is inaccessible because it is mounted with the far end 48 inches from the rear wall. |
ST6 |
12 months |
12.7. |
Exterior WomenÕs Toilet Room |
||
12.7.a. |
The toilet room sign is mounted on the door. |
TR18 |
12 months |
12.7.b. |
The pull side of the door, which is accessed through a front approach, is inaccessible because it has 7 inches of clear space on the latch side. |
D6 |
12 months |
12.7.c. |
No accessible mirror has been provided. |
TR14 |
12 months |
12.7.d. |
The air dryers protrude into the walkway and are not detectable to blind persons using a cane. |
AR8 |
12 months |
12.7.e. |
The designated accessible toilet is inaccessible because its centerline is 20 inches from the side wall. |
ST17 |
12 months |
12.7.f. |
The designated accessible toilet is inaccessible because the flush control is on the closed side. |
ST2 |
12 months |
12.7.g. |
The toilet paper dispenser in the designated accessible stall is inaccessible because it is mounted 39 inches from the rear wall. |
ST19 |
12 months |
12.7.h. |
The side grab bar at the designated accessible toilet is inaccessible because it is mounted with the far end 47 inches from the rear wall. |
ST7 |
12 months |
12.7.i. |
The rear grab bar at the designated accessible toilet is inaccessible because it is 24 inches long and it is mounted 6½ inches from the side wall. |
ST4 |
12 months |
13. |
Eastwood Country Club - 4600 Bruce Herd Lane |
||
13.1. |
Parking: The parking lot, with a total of 230 parking spaces, is inaccessible because it only has 6 spaces designated as accessible, and 3 of the designated accessible spaces have slopes between 2.6% and 3%. This lot requires 1 van accessible space and 6 standard accessible spaces or 7 universal design spaces. |
P3 |
12 months |
13.2. |
Club House Lobby |
||
13.2.a. |
The lower drinking fountain is inaccessible because the controls require 7 pounds of force to operate. |
DF2 |
12 months |
13.2.b. |
The higher drinking fountain protrudes into the walkway and is not detectable to blind persons using a cane. |
AR8 |
12 months |
13.3. |
Club House Lobby MenÕs Toilet Room |
||
13.3.a. |
The door is inaccessible because it requires 17 pounds of force to open. |
D2 |
12 months |
13.3.b. |
The pull side of the door, which is accessed through a front approach, is inaccessible because the clear floor space is obstructed by a chair. |
D6 |
12 months |
13.4. |
Club House Lobby WomenÕs Toilet Room |
||
13.4.a. |
The door is inaccessible because it requires 16 pounds of force to open. |
D2 |
12 months |
13.4.b. |
The pull side of the door, which is accessed through a front approach, is inaccessible because the clear floor space is obstructed by a chair. |
D6 |
12 months |
13.5. |
Clubroom Snack Bar: The counter protrudes into the walkway and is not detectable to blind persons using a cane. |
AR8 |
12 months |
13.6. |
Pro Shop |
||
13.6.a. |
The benches in the 2 unisex dressing rooms are inaccessible because they are 17 inches deep, 42 inches long, and not fixed to the wall. |
LR1 |
12 months |
13.6.b. |
No accessible clothes rod has been provided. |
TR1 |
12 months |
13.7. |
Gazebo |
||
13.7.a. |
The snack bar counter protrudes into the walkway and is not detectable to blind persons using a cane. |
AR8 |
12 months |
13.7.b. |
Although a designated accessible drinking fountain is provided, there is no drinking fountain provided for people who have difficulty bending or stooping. |
DF3 |
12 months |
13.7.c. |
The drinking fountain protrudes into the walkway and is not detectable to blind persons using a cane. |
AR8 |
12 months |
13.8.
|
Top 9 and Back 9 Toilet Rooms (Existing): The menÕs and womenÕs toilet rooms contain a number of inaccessible elements and are not accessible to people with disabilities. |
TR22 |
12 months |
13.9. |
StartersÕ Booth (Existing): The service window is inaccessible because it is 48 inches above the finished floor. |
C5 |
12 months |
13.10. |
Golf Carts: Although there are golf carts for public use at this facility, none are accessible to persons who use wheelchairs. |
G1 |
12 months |
14. |
Trailhead Park - 3600 Veronica Shoemaker Drive |
||
14.1. |
WomenÕs Single User Toilet Room |
||
14.1.a. |
The toilet paper dispenser in the designated accessible stall is inaccessible because it is mounted 18 inches above the finished floor. |
SU17 |
12 months |
14.1.b. |
The rear grab bar at the toilet is inaccessible because it is obstructed by the toilet flush valve. |
SU4 |
12 months |
14.2. |
MenÕs Single User Toilet Room |
||
14.2.a. |
The toilet paper dispenser in the designated accessible stall is inaccessible because it is mounted 18 inches above the finished floor. |
SU17 |
12 months |
14.2.b. |
The rear grab bar at the toilet is inaccessible because it is obstructed by the toilet flush valve. |
SU4 |
12 months |
14.3. |
Pavilion #1 |
||
14.3.a. |
The drinking fountain is inaccessible because the flow of water is 3 inches high. |
DF7 |
12 months |
14.3.b. |
The drinking fountains protrude into the walkway and are not detectable to blind persons using a cane. |
AR8 |
12 months |
14.4. |
Pavilions 3 & 4: The route to the grill is inaccessible because the grass is not firm, stable, and slip resistant. |
AR1 |
12 months |
15. |
Riverside Park and Community Center |
||
15.1. |
Community Center Entrance Ramp: The ramp is inaccessible because the top landing is 56 inches long. |
R5 |
12 months |
15.2. |
Lobby MenÕs Toilet Room |
||
15.2.a. |
The door is inaccessible because it requires 7 pounds of force to open. |
D2 |
12 months |
15.2.b. |
No accessible mirror has been provided. |
TR14 |
12 months |
15.2.c. |
The side grab bar at the designated accessible toilet is inaccessible because it is obstructed by the toilet paper dispenser. |
ST8 |
12 months |
15.3. |
Lobby WomenÕs Toilet Room |
||
15.3.a. |
The door is inaccessible because it requires 12 pounds of force to open. |
D2 |
12 months |
15.3.b. |
The side grab bar at the designated accessible toilet is inaccessible because it is obstructed by the toilet paper dispenser. |
ST8 |
12 months |
15.4. |
Drinking Fountain by Toilet Rooms: The drinking fountain is inaccessible because the flow of water is 2 inches high. |
Df7 |
12 months |
15.5. |
Wood Shop: The door is inaccessible because it requires 11 pounds of force to open |
D2 |
12 months |
15.6. |
Classroom: The door is inaccessible because it requires 12 pounds of force to open. |
D2 |
12 months |
15.7. |
North Exit Door Off Main Corridor: The door is inaccessible because there is a 1½ inch high threshold. |
D22 |
12 months |
15.8. |
Anderson Hall |
||
15.8.a. |
The double doors are inaccessible because they require 20 pounds of force to open. |
D2 |
12 months |
15.8.b. |
The ramp to the stage is inaccessible because it has a slope of up to 9.4%, the handrails are mounted 1¾ inches from the wall, and the top landing is 50 inches long. |
R3 |
12 months |
15.9. |
Ceramic Shop: The door is inaccessible because it requires 12 pounds of force to open. |
D2 |
12 months |
15.10. |
Kitchen |
||
15.10.a.
|
The door is inaccessible because it requires 9 pounds of force to open. |
D2 |
12 months |
15.10.b.
|
The hand-washing sink is inaccessible because the knee space is obstructed by the stopper lever and the hot water pipes are not insulated or otherwise configured to protect against contact. |
S2 |
12 months |
15.10.c.
|
The exit door is inaccessible because there is a 1¾ inch high threshold. |
D22 |
12 months |
15.10.d.
|
The pull side of the exit door is inaccessible because it has only 14½ inches of clear space on the latch side. |
D8, D9, D10 |
12 months |
15.11. |
Exit Door from Corridor to Porch: The door is inaccessible because there is a 1¾ inch high threshold. |
D22 |
12 months |
15.12. |
Exit Door from Corridor South Side: The door is inaccessible because there is a 1¾ inch high threshold. |
D22 |
12 months |
15.13. |
Park |
||
15.13.a.
|
The toilet room sign at the designated accessible portable toilet is mounted on the door and has no raised or Braille characters. |
TR18 |
12 months |
15.13.b.
|
The side grab bar at the designated accessible portable toilet is inaccessible because it is obstructed by the toilet paper dispenser. |
SU7 |
12 months |
15.13.c.
|
The designated accessible portable toilet is inaccessible because it provides insufficient clear floor space at the toilet. |
SU16 |
12 months |
15.13.d.
|
The routes to the grills near each pavilion are inaccessible because the grass is not firm, stable, and slip resistant. |
AR1 |
12 months |
15.13.e.
|
The picnic tables at each pavilion are inaccessible because none provide the required knee space. |
PD6 |
12 months |
15.13.f.
|
The drinking fountain near the play area is inaccessible because it requires 13 pounds of force to operate. |
DF2 |
12 months |
15.13.g.
|
The drinking fountain near the play area is inaccessible because the clear floor space has a slope of 7.1%. |
DF5 |
12 months |
15.14. |
Fixed Pier: The route to the fixed pier is inaccessible because there is a 1½ inch change in the level on the sidewalk. |
AR1 |
12 months |