ATTACHMENT J: Modifications to Altered Facilities

 

Please Note: Paragraph 57 of the Settlement Agreement requires that within three months of the effective date of this Agreement, the County provide signage as necessary to comply with 28 C.F.R. § 35.163(b), after having surveyed all facilities that are the subject of this Agreement for the purpose of identifying those that have multiple entrances not all of which are accessible.

The chart below lists the facilities surveyed by the Department, the access issues identified during the survey, and the actions required to correct the access issues. Required actions are listed using an alphanumeric code. The key to the alphanumeric codes is provided in Attachment M to this Agreement.

In order to ensure that the following spaces and elements in the County's facilities in which alterations occurred after January 26, 1992, are readily accessible to and usable by persons with disabilities, the County will take the actions referenced by the alphanumeric code and described in detail in Attachment M to this Settlement Agreement within the time period specified below, which time period will begin to run on the effective date of this Agreement.

Item #

Access Issue

Required Action

Completion Date

1

Federal Building, located at 34 West Peter Street, Uniontown

 

 

1.1

Parking: The parking lot, with a total of 10 parking spaces, is not accessible because the designated accessible parking space does not have vertical signage, there is a grate located between the designated accessible space and access aisle, and the space is not located on the shortest accessible route to the accessible entrance. This lot requires 1 van accessible space.

P3

9 months

1.2

Signage: The building does not have directional signage posted at the inaccessible entrance and does not have the International Symbol of Accessibility posted at the accessible side entrance.

D16

9 months

1.3

Side Entrance: The interior entrance door (past the stairs) is inaccessible because it requires 11 pounds of force to open.

D2

9 months

1.4

Juvenile Probation Office Reception

 

 

1.4.a

The door is inaccessible because it requires 10 pounds of force to open.

D2

9 months

1.4.b

The reception counter is inaccessible because it is 43 inches high.

C6

9 months

1.4.c

The reception counter protrudes into the walkway and is not detectable to blind persons using a cane.

AR8

9 months

1.4.d

The telephone next to the reception counter is inaccessible because the highest control is more than 54 inches high.

TT1

9 months

1.5

Juvenile Probation Unisex Single User Toilet Room: The toilet room sign is not centered 60 inches high and does not have the International Symbol of Accessibility.

TR17

9 months

1.6

Juvenile Probation Employee Single User Toilet Room by Stairs: The toilet room sign is centered 56 inches high.

TR17

9 months

1.7

Juvenile Probation Employee Single User Toilet Room in Employee Lounge

 

 

1.7.a

The toilet room sign is centered 56 inches high.

TR17

9 months

1.7.b

No accessible mirror has been provided.

TR14

9 months

1.8

Mezzanine Level Toilet Rooms (existing element): The toilet room signs are centered 56 inches high.

TR17

9 months

1.9

Coroner's Office (existing element)

 

 

1.9.a

The counter is inaccessible because it is 41 inches high.

C6

9 months

1.9.b

The drinking fountain is inaccessible because it has a spout that is 42 inches high.

DF6

9 months

1.10

Lower Level: The wall-mounted fire extinguisher protrudes into the walkway and is not detectable to blind persons using a cane.

AR8

9 months

2

Public Services Building, located at 22 East Main, Uniontown

 

 

2.1

Main entrance: The main entrance is inaccessible because there is a slope of 9.6% within the door's required maneuvering clearance.

D13

6 months

2.2

4th Floor Drinking Fountain: The drinking fountain protrudes into the walkway and is not detectable to blind persons using a cane.

AR8

6 months

2.3

4th Floor Women's Toilet and Shower Room

 

 

2.3.a

The toilet room sign is mounted on the door.

TR17

6 months

2.3.b

The designated accessible toilet is inaccessible because the flush control is on the closed side.

ST2

6 months

2.4

4th Floor Men's Toilet and Shower Room

 

 

2.4.a

The toilet room sign is mounted on the door.

TR17

6 months

2.4.b

The route to the urinal is inaccessible because it is less than 36 inches wide.

AR3

6 months

2.4.c

The urinal is inaccessible because the rim is 17½ inches high, and the flush control is 45 inches high.

TR20

6 months

2.4.d

The designated accessible toilet is inaccessible because its centerline is 19 inches from the side wall.

ST17

6 months

2.5

3rd Floor Adult Probation Office Reception Counter (existing element)

 

 

2.5.a

The counter is inaccessible because it is 49 inches high.

C6

6 months

2.5.b

The counter protrudes into the walkway and is not detectable to blind persons using a cane.

AR8

6 months

2.6

3rd Floor Adult Probation Drug Testing Single User Toilet Room (existing element)

 

 

2.6.a

The toilet room is inaccessible because there is insufficient turning space provided within the room.

TR19

6 months

2.6.b

The toilet is inaccessible because the centerline is 17 inches from the side wall.

SU15

6 months

2.6.c

The side grab bar at the toilet is inaccessible because it is 36 inches long, and the far end is 40 inches from the rear wall.

SU6

6 months

2.6.d

The wall-mounted cabinet next to the toilet protrudes into the walkway and is not detectable to blind persons using a cane.

AR8

6 months

2.7

2nd Floor Domestic Relations Office Reception Counter (existing element): The counter is inaccessible because it is 39 inches high.

C6

6 months

2.8

2nd Floor Domestic Relations Office Client Single User Toilet Room (existing element)

 

 

2.8.a

The toilet room sign is mounted on the door.

TR17

6 months

2.8.b

The toilet room is inaccessible because there is insufficient turning space provided within the room.

TR19

6 months

2.8.c

The lavatory is inaccessible because the clear floor space is 45 inches deep.

TR8

6 months

2.8.d

The toilet is inaccessible because the centerline is 19 inches from the side wall.

SU15

6 months

2.8.e

The toilet is inaccessible because the flush control is on the closed side.

SU1

6 months

2.8.f

The side grab bar at the toilet is inaccessible because it is mounted with the far end 52 inches from the rear wall.

SU6

6 months

2.8.g

The toilet is inaccessible because the grab bars are mounted 37 inches high.

SU11

6 months

2.9

1st Floor Drinking Fountain (existing element): The lower drinking fountain is inaccessible because the knee clearance is 26 inches high.

DF5

6 months

2.10

1st Floor Accessible Route: The shelf next to the drinking fountains protrudes into the walkway and is not detectable to blind persons using a cane.

AR8

6 months

2.11

1st Floor Public Women's Toilet Room (existing element)

 

 

2.11.a

The centerline of the toilet room sign is not 60 inches above the finished floor.

TR17

6 months

2.11.b

The door is inaccessible because it requires 10 pounds of force to open.

D2

6 months

2.12

1st Floor Public Men's Toilet Room (existing element)

 

 

2.12.a

The centerline of the toilet room sign is not 60 inches above the finished floor.

TR17

6 months

2.12.b

The door is inaccessible because it requires more than 5 pounds of force to open.

D2

6 months

2.12.c

The pull side of the door, which is accessed through a front approach, is inaccessible because it has only 7 inches of clear space on the latch side.

D6

6 months

2.12.d

No accessible mirror has been provided.

TR14

6 months

2.12.e

The paper towel dispenser is inaccessible because it is mounted with its controls 57 inches high.

TR5

6 months

2.12.f

The designated accessible toilet is inaccessible because the rear grab bar is obstructed by the automatic flush mechanism.

ST5

6 months

2.13

1st Floor Meeting Room (existing element)

 

 

2.13.a

The door is inaccessible because it requires 9 pounds of force to open.

D2

6 months

2.13.b

There is no accessible route provided to the raised dais due to a 8½ inch step.

AA8

6 months

2.14

Elevator (existing element): The elevator is inaccessible because the gap between the elevator cab and hoistway is 1½ inches.

E10

12 months

 