ATTACHMENT I: Modifications to Newly Constructed Facilities
Please Note: Paragraph 57 of the Settlement Agreement requires that within three months of the effective date of this Agreement, the County provide signage as necessary to comply with 28 C.F.R. § 35.163(b), after having surveyed all facilities that are the subject of this Agreement for the purpose of identifying those that have multiple entrances not all of which are accessible. The chart below lists the facilities surveyed by the Department, the access issues identified during the survey, and the actions required to correct the access issues. Required actions are listed using an alphanumeric code. The key to the alphanumeric codes is provided in Attachment M to this Agreement. In order to ensure that the following spaces and elements in County facilities, for which construction was commenced after January 26, 1992, are readily accessible to and usable by persons with disabilities, the County will take the actions referenced by the alphanumeric code and described in detail in Attachment M to this Settlement Agreement within the time periods specified below, which time periods will begin to run on the effective date of this Agreement. |
|||
Item # |
Access Issue |
Required Action |
Completion Date |
---|---|---|---|
1.
|
Fayette Area Coordinated Transportation (FACT), located at 825 Airport Road, Lemont Furnace |
|
|
1.1.
|
Curb Ramp by Main Entrance: The curb ramp is inaccessible because it has a slope of 11.4%. |
AR5 |
6 months |
1.2.
|
Main Entrance |
|
|
1.2.a.
|
The entrance is inaccessible because the threshold is ¾ inch high. |
D22 |
12 months |
1.2.b.
|
The entrance is inaccessible because the inner vestibule door requires 9 pounds of force to open. |
D2 |
6 months |
1.3.
|
Ramp to Employee Entrance: The ramp is inaccessible because it slopes up to 9.1% in some areas, and the handrails do not extend 12 inches parallel to the ground surface at the top and bottom of the ramp. |
R5 |
12 months |
1.4.
|
Outdoor employee seating: The table provided for employees is inaccessible because the attached seats obstruct the required knee clearances. |
T1 |
6 months |
1.5.
|
Fire Extinguisher Cases: Throughout the facility, the wall-mounted fire extinguisher cases protrude into the walkway and are not detectable to blind persons using a cane. |
AR8 |
6 months |
1.6.
|
Employee Lounge: The door is inaccessible because it requires 14 pounds of force to open. |
D2 |
6 months |
1.7.
|
Waiting Room Drinking Fountain: Although an accessible drinking fountain is provided, there is no drinking fountain provided for people who have difficulty bending or stooping. |
DF3 |
6 months |
1.8.
|
Waiting Room Men's Toilet Room with Stalls 118 |
|
|
1.8.a.
|
The door is inaccessible because it requires 7 pounds of force to open. |
D2 |
6 months |
1.8.b.
|
No accessible mirror has been provided. |
TR14 |
6 months |
1.8.c.
|
The paper towel dispenser protrudes into the walkway and is not detectable to blind persons using a cane. |
AR8 |
6 months |
1.9.
|
Waiting Room Women's Toilet Room with Stalls 119 |
|
|
1.9.a.
|
The door is inaccessible because it requires 11 pounds of force to open. |
D2 |
6 months |
1.9.b.
|
No accessible mirror has been provided. |
TR14 |
6 months |
1.9.c.
|
The paper towel dispenser protrudes into the walkway and is not detectable to blind persons using a cane. |
AR8 |
6 months |
1.10.
|
Meeting room 117: The meeting room is inaccessible to people with hearing disabilities because there is no assistive listening system provided. |
AA5 |
12 months |
1.11.
|
Upper Level Men's Toilet Room with Stalls 129 |
|
|
1.11.a.
|
The door is inaccessible because it requires 9 pounds of force to open. |
D2 |
6 months |
1.11.b.
|
No accessible mirror has been provided. |
TR14 |
6 months |
1.11.c.
|
The paper towel dispenser is inaccessible because the controls are mounted 56 inches high over the lavatory. |
TR4 |
6 months |
1.11.d.
|
The lavatory is inaccessible because the bottom edge of the apron is 27½ inches high. |
TR11 |
12 months |
1.11.e.
|
The urinals are inaccessible because the lower urinal rim is 18 inches high. |
TR20 |
12 months |
1.11.f.
|
The designated accessible toilet is inaccessible because the centerline is 19 inches from the side wall. |
ST17 |
6 months |
1.11.g.
|
The designated accessible toilet is inaccessible because the rear grab bar is mounted 8 inches from the side wall. |
ST4 |
6 months |
1.12.
|
Upper Level Women's Toilet Room with Stalls 128 |
|
|
1.12.a.
|
The door is inaccessible because it requires 8 pounds of force to open. |
D2 |
6 months |
1.12.b.
|
No accessible mirror has been provided. |
TR14 |
6 months |
1.12.c.
|
The lavatory is inaccessible because the bottom edge of the apron is 27 inches high. |
TR11 |
12 months |
1.12.d.
|
The designated accessible toilet is inaccessible because the centerline is 19 inches from the side wall. |
ST17 |
6 months |
1.12.e.
|
The designated accessible toilet is inaccessible because the rear grab bar is mounted 8 inches from the side wall. |
ST4 |
6 months |
1.13.
|
Upper Level Entrance Door to Hallway: The door is inaccessible because it requires 8 pounds of force to open. |
D2 |
6 months |
1.14.
|
Elevator |
|
|
1.14.a.
|
The elevator is inaccessible because the hall call buttons are mounted 39 inches above the finished floor. |
E3 |
6 months |
1.14.b.
|
The elevator is inaccessible because the emergency controls are not grouped at the bottom of the panel. |
E9 |
6 months |
1.14.c.
|
In a test of the elevator's emergency communications to determine how silent calls would be handled, the operator indicated she did not know the location of the elevator without a verbal description from the elevator user. |
E8 |
6 months |
1.15.
|
Lower Level Break Room: No accessible coat hook has been provided. |
TR1 |
6 months |
1.16.
|
Lower Level Drinking Fountains: Although accessible drinking fountains are provided, there is no drinking fountain provided for people who have difficulty bending or stooping. |
DF3 |
6 months |
1.17.
|
Lower Level Men's Toilet Room with Stalls 05 |
|
|
1.17.a.
|
The door is inaccessible because it requires 15 pounds of force to open. |
D2 |
6 months |
1.17.b.
|
No accessible mirror has been provided. |
TR14 |
6 months |
1.17.c.
|
The dressing bench provided is inaccessible because it is 9½ inches wide and is not attached to the wall. |
LR1 |
6 months |
1.18.
|
Lower Level Women's Toilet Room with Stalls 04 |
|
6 months |
1.18.a.
|
The door is inaccessible because it requires 13 pounds of force to open. |
D2 |
6 months |
1.18.b.
|
No accessible mirror has been provided. |
TR14 |
6 months |
1.18.c.
|
The designated accessible lavatory is inaccessible because it is obstructed by a free-standing trash can. |
TR8 |
6 months |
1.18.d.
|
The designated accessible toilet is inaccessible because the rear grab bar is mounted 8 inches from the side wall. |
ST4 |
6 months |
1.18.e.
|
The dressing bench provided is inaccessible because it is 9½ inches wide and is not attached to the wall. |
LR1 |
6 months |
1.19.
|
Lower Level Garage Break Room |
|
6 months |
1.19.a.
|
The door is inaccessible because it requires more than 5 pounds of force to open. |
D2 |
6 months |
1.19.b.
|
The coat rack is inaccessible because it is mounted with the controls 64 inches high. |
TR5 |
6 months |
1.20.
|
Lower Level Unisex Toilet Room in Garage Break Room |
|
|
1.20.a.
|
The door is inaccessible because it requires 11 pounds of force to open. |
D2 |
6 months |
1.20.b.
|
No accessible mirror has been provided. |
TR14 |
6 months |
1.20.c.
|
The lavatory is inaccessible because it is operable only by using a floor-level pedal, which is below the minimum height requirements. |
TR2 |
6 months |
1.20.d.
|
The toilet is inaccessible because its centerline is 19 inches from the side wall. |
SU15 |
6 months |
1.20.e.
|
The dressing area bench is inaccessible because it is 15½ inches wide and 15½ inches high. |
LR1 |
6 months |
2.
|
Fayette County Children and Youth Services Building, located at 130 New Salem Road, Uniontown |
|
|
2.1.
|
Parking: The parking lot, with a total of 48 parking spaces, is inaccessible because it has no van accessible parking space, and two of the designated accessible spaces have cross slopes between 3.3% and 5.1%. This lot requires 1 van accessible space and 1 standard accessible space. |
P3 |
6 months |
2.2.
|
Interior Doors with Closers: The doors throughout the facility are inaccessible because they require more than 5 pounds of force to open. |
D2 |
6 months |
2.3.
|
Reception Counter |
|
|
2.3.a.
|
The counter is inaccessible because it is 41 inches high. |
C6 |
6 months |
2.3.b.
|
The counter protrudes into the walkway and is not detectable to blind persons using a cane. |
AR8 |
6 months |
2.4.
|
Visitation Room #2: The push side of the door, which is accessed through a front approach and which has both a closer and a latch, is inaccessible because it has 1¾ inches of maneuvering clearance on the latch side. |
D7 |
6 months |
2.5.
|
Women's Public Single User Toilet Room |
|
|
2.5.a.
|
The toilet room is inaccessible because there is insufficient turning space provided within the room. |
TR19 |
6 months |
2.5.b.
|
The toilet is inaccessible because the flush control is on the closed side. |
SU1 |
6 months |
2.5.c.
|
The side grab bar at the toilet is inaccessible because it is obstructed by the toilet paper dispenser. |
SU7 |
6 months |
2.5.d.
|
The side grab bar at the toilet is inaccessible because it is mounted with the far end 50 inches from the rear wall. |
SU6 |
6 months |
2.5.e.
|
The rear grab bar at the toilet is inaccessible because it is 32 inches long and it is obstructed by the soap dispenser. |
SU2 |
6 months |
2.6.
|
Men's Public Single User Toilet Room |
|
|
2.6.a.
|
The toilet room is inaccessible because there is insufficient turning space provided within the room. |
TR19 |
6 months |
2.6.b.
|
The toilet is inaccessible because its centerline is 19 inches from the side wall. |
SU15 |
6 months |
2.6.c.
|
The side grab bar at the toilet is inaccessible because it is obstructed by the toilet paper dispenser. |
SU7 |
6 months |
2.6.d.
|
The side grab bar at the toilet is inaccessible because it is mounted with the far end 50 inches from the rear wall. |
SU6 |
6 months |
2.6.e.
|
The rear grab bar at the toilet is inaccessible because it is 30 inches long and it is obstructed by the soap dispenser. |
SU2 |
6 months |
2.7.
|
Employee Key Pads: The key pads used for entrance to employee areas protrude into the walkway and are not detectable to blind persons using a cane. |
AR8 |
6 months |
2.8.
|
Women's Staff Toilet Room with Stalls |
|
|
2.8.a.
|
The toilet room sign is mounted 58 inches above the finished floor. |
TR18 |
6 months |
2.8.b.
|
The pull side of the door, which is accessed from the latch side, is inaccessible because it has only 47 inches of maneuvering width. Because the door has a closer, 54 inches of clear width is required. |
D10 |
6 months |
2.8.c.
|
No accessible mirror has been provided. |
TR14 |
6 months |
2.8.d.
|
The lavatory is inaccessible because it does not provide sufficient knee clearance. |
TR11 |
6 months |
2.8.e.
|
The designated accessible toilet is inaccessible because the top of the seat is 19½ inches high. |
ST20 |
6 months |
2.8.f.
|
The designated accessible toilet is inaccessible because the centerline is 17 inches from the side wall. |
ST17 |
6 months |
3.
|
Fayette County Mental Health and Mental Retardation Program facility, located at 215 Jacobs Murphy Road, Uniontown |
|
|
3.1.
|
Parking: The signage designating parking as reserved for persons with disabilities is mounted too low. |
P6 |
6 months |
3.2.
|
Reception Counter |
|
|
3.2.a.
|
The counter is inaccessible because it is 38 inches high. |
C6 |
6 months |
3.2.b.
|
The counter protrudes into the walkway and is not detectable to blind persons using a cane. |
AR8 |
6 months |
3.3.
|
Drinking Fountain: The wall-mounted drinking fountain is inaccessible because the knee clearance is 26 inches high. |
DF5 |
6 months |
3.4.
|
First Floor Women's Toilet Room with Stalls |
|
|
3.4.a.
|
The pull side of the door, which is accessed through a front approach, is inaccessible because it has 16 inches of maneuvering clearance on the latch side. |
D6 |
6 months |
3.4.b.
|
The lavatory is inaccessible because the rim or counter is 35 inches high to the top. |
TR11 |
6 months |
3.4.c.
|
The designated accessible toilet is inaccessible because the centerline is 19 inches from the side wall. |
ST17 |
6 months |
3.5.
|
First Floor Men's Toilet Room with Stalls |
|
|
3.5.a.
|
The door is inaccessible because it requires 10 pounds of force to open. |
D2 |
6 months |
3.5.b.
|
The designated accessible toilet is inaccessible because the top of the toilet seat is 20 inches high. |
ST20 |
6 months |
3.6.
|
Visionary Room: The route to the Visionary Room is inaccessible because the vestibule door requires 10 pounds of force to open and the room door requires 12 pounds of force to open. |
D2 |
6 months |
3.7.
|
Second Floor Men's Toilet Room |
|
|
3.7.a.
|
The door is inaccessible because it requires 11 pounds of force to open. |
D2 |
6 months |
3.7.b.
|
The designated accessible toilet is inaccessible because the top of the toilet seat is 19½ inches high. |
ST20 |
6 months |
3.8.
|
Second Floor Women's Toilet Room |
|
|
3.8.a.
|
The door is inaccessible because it requires 12 pounds of force to open. |
D2 |
6 months |
3.8.b.
|
The designated accessible toilet is inaccessible because the top of the toilet seat is 19½ inches high. |
ST20 |
6 months |
4.
|
Fayette County Prison Annex, located at 61 East Main Street, Uniontown |
|
|
4.1.
|
Visitor Area Telephones: The telephones are inaccessible because the cords are 24 inches long and none of the telephones is equipped with volume control or is hearing aid compatible. |
TT1 |
6 months |
4.2.
|
Unisex Visitor Toilet Room |
|
|
4.2.a.
|
The toilet room sign is mounted on the door. |
TR18 |
6 months |
4.2.b.
|
No accessible mirror has been provided. |
TR14 |
6 months |
4.2.c.
|
The toilet is inaccessible because the centerline is 19½ inches from the near side wall. |
SU15 |
6 months |
4.3.
|
Unisex Employee Toilet Room |
|
|
4.3.a.
|
The toilet room sign is mounted on the door. |
TR18 |
6 months |
4.3.b.
|
No accessible mirror has been provided. |
TR14 |
6 months |
4.3.c.
|
Although an audible alarm is provided in this facility, there is no visual alarm appliance in the toilet room. |
TR21 |
12 months |
4.3.d.
|
The toilet is inaccessible because the centerline is 24 inches from the near side wall. |
SU15 |
6 months |
4.4.
|
Visitor Lobby Drinking Fountains: The higher drinking fountain protrudes into the walkway and is not detectable to blind persons using a cane. |
AR8 |
6 months |
4.5.
|
Inmate Area Telephones |
|
|
4.5.a.
|
Although there are 4 public telephones provided, a TTY is not provided. |
TT2 |
6 months |
4.5.b.
|
There is no accessible telephone because, at the lowered telephone, the cord is 19 inches long and there is no volume control mechanism. |
TT1 |
6 months |
4.6.
|
Route in Inmate Area: Near the guard station, there is a wall-mounted shelf that protrudes into the walkway and is not detectable to blind persons using a cane. |
AR8 |
6 months |
4.7.
|
Toilets, Urinals, Lavatories, Showers, and Accessories in Inmate Area |
|
|
4.7.a.
|
No accessible mirror has been provided. |
TR14 |
6 months |
4.7.b.
|
The designated accessible toilet is inaccessible because the centerline is 20 inches from the near side wall. |
ST17 |
6 months |
4.7.c.
|
The side grab bar at the designated accessible toilet is inaccessible because it is mounted with the far end less than 52 inches from the rear wall. |
ST7 |
6 months |
4.7.d.
|
No accessible shower is provided. |
B8 |
6 months |
4.8.
|
Drinking Fountains in Inmate Area |
|
|
4.8.a.
|
The drinking fountains are inaccessible because the route to them narrows to 25 inches wide due to the placement of a bunk bed. |
AR3 |
6 months |
4.8.b.
|
The drinking fountain protrudes into the walkway and is not detectable to blind persons using a cane. |
AR8 |
6 months |
4.9.
|
Inmate Laundry Area: The route to the laundry machines for inmate use is inaccessible because it narrows to less than 32 inches wide. |
AR3 |
6 months |