Attachment I: Modifications to Newly Constructed Facilities

Please Note:  Paragraph 90 of the Settlement Agreement requires that, within three months of the effective date of this Agreement, the County  provide signage as necessary to comply with 28 C.F.R. § 35.163(b), after having surveyed all facilities that are the subject of this Agreement for the purpose of identifying those that have multiple entrances not all of which are accessible.

The chart below lists the facilities surveyed by the Department, the access issues identified during the survey, and the actions required to correct the access issues.  Required actions are listed using an alphanumeric code.  The key to the alphanumeric codes is provided in Attachment M to this Agreement. 

In order to ensure that the following spaces and elements in County facilities for which construction was commenced after January 26, 1992, are readily accessible to and usable by persons with disabilities, the County will take the actions referenced by the alphanumeric code and described in detail in Attachment M to this Settlement Agreement within the time periods specified below, which time periods will begin to run on the effective date of this Agreement.

Access Issue

Required Action

Completion Date 

1.   Kingstowne Library

      6500 Landsdowne Center  

      Alexandria, VA 22315

   

1.1     Route to Entrance

   

1.1. a The curb ramp closest to the entry is inaccessible because it has a right flared side with a slope measuring 14.2%.

AR5

6 months

1.2     Telephone in Vestibule

   

1.2. a The telephone is inaccessible because the clear floor space is obstructed by an easel.

TT1

6 months

1.3     Toilet Rooms

   

1.3. a Women's Room

   

1.3. a (1)  The walkway is inaccessible because the air dryer and the sanitary napkin dispenser protrude into the walkway and would not be detectable to a blind person using a cane.

AR8

6 months

1.3. a (2)  The sanitary napkin dispenser is inaccessible because it requires tight grasping.

TR3

6 months

1.3. b Men's Room

   

1.3. b (1) The walkway is inaccessible because the air dryer protrudes into the walkway and would not be detectable to a blind person using a cane.

AR8

6 months

1.4     Drinking Fountain near Toilet Rooms

   

1.4. a The wall-mounted lower drinking fountain is inaccessible because the knee clearance is less than 27 inches high.

DF5

6 months

2.   Braddock District Government Center

      9002 Burke Lake Road

      Burke, VA 22015

   

2.1     Parking

   

2.1. a The van accessible parking reserved for persons with disabilities is inaccessible because it lacks the appropriate signage.

P6

6 months

2.2     Accessible Route

   

2.2. a The route from the parking lot to the entrance is inaccessible because the curb ramp leading from the parking has a primary slope of 10.7% and flared sides with slopes of 15.5% and 13.7%.

AR5

6 months

2.3     Offices

   

2.3. a The doors to reception and the meeting hall are inaccessible because the pressure required to open the doors is 15 pounds.

D2

6 months

2.4     Toilet Rooms

   

2.4. a The toilet rooms were not surveyed.

ST14

6 months

3.   Government Center Sully District Police

     4900 Stonecroft Blvd

      Chantilly, VA 20151

   

3.1     Parking

   

3.1. a The parking reserved for persons with disabilities is inaccessible because the designated van space furthest from the building has an access aisle that is 64 inches wide. 

P8

6 months

3.2     Internal Accessible Route

   

3.2. a The walkway is inaccessible because the defibrillator near the front desk protrudes into the walkway and would not be detectable to a blind person using a cane.

AR8

6 months

3.3     Rooms and Offices

   

3.3. a Room 123-Conference Room

   

3.3. a (1)  The wall phone and the TV/VCR are inaccessible because the controls are mounted at 62 inches above the finished floor. 

TR5

6 months

3.3. b Copy Room

   

3.3. b (1) The Laser color printer is inaccessible because the highest control is mounted at 57 inches above the finished floor.

TR5

6 months

3.3. c Interview Rooms #1, 2 and 3-Rooms 147, 148 and 149

   

3.3. c (1)  The interview tables are inaccessible because the knee clearance is 26 inches high.

T1

6 months

3.3. d Mail Room

   

3.3. d (1) The telephone in the mail room is inaccessible because the highest operable part is 57 inches from the floor.

TT1

6 months

3.3. e Room 158-Roll Call

   

3.3. e (1)  The walkway is inaccessible because the TV monitor and operating mechanism protrude into the walkway and would not be detectable to a blind person using a cane.

AR8

6 months

3.4     Men's Locker Rooms

   

3.4. a The bench is inaccessible because it is 10 inches wide.

LR1

6 months

3.4. b There is no accessible locker provided.

LR3

6 months

3.5     Women's Locker Room

   

3.5. a The bench is inaccessible because it is 10 inches wide.

LR1

6 months

3.5. b There is no accessible locker provided.

LR3

6 months

3.5. c The route to the paper towel dispenser is inaccessible because there is only 26 inches of width by the table.

AR3

6 months

3.5. d The sanitary napkin dispenser is inaccessible because the controls are mounted at 58 inches above the floor.

TR4

6 months

3.5. e The walkway is inaccessible because the sanitary napkin dispenser protrudes into the walkway and would not be detectable to a blind person using a cane.

AR8

6 months

3.5. f  The shelves and hooks in the locker room are inaccessible because they are more than 54 inches above the finished floor.

S1

6 months

3.6     Men's Public Toilet Room

   

3.6. a The walkway is inaccessible because the air dryers protrude into the walkway and would not be detectable to a blind person using a cane.

AR8

6 months

3.6. b The toilet room door is inaccessible because the pressure required to open the door is 8 pounds.

D2

6 months

3.7     Women's Public Toilet Room

   

3.7. a The walkway is inaccessible because the air dryers and the sanitary napkin dispenser protrude into the walkway and would not be detectable to a blind person using a cane.

AR8

6 months

3.7. b The sanitary napkin dispenser is inaccessible because the controls are mounted at 59.5 inches above the finished floor.

TR5

6 months

3.7. c The toilet room door is inaccessible because the pressure required to open the door is 8 pounds.

D2

6 months

4.   Cub Run Recreation Center

      4630 Stonecroft Blvd.

      Chantilly, VA 20151

   

4.1     Accessible Route

   

4.1. a   The ramp located on the route from the parking on left side of building to the entrance is inaccessible because it does not have adequate edge protection.

R1

6 months

4.2     Conference Room 129

   

4.2. a   The telephone is inaccessible because the highest operable part is 58 inches from the floor.

TT1

6 months

4.3     Copier Area

   

4.3. a   The printer is inaccessible because the highest control is mounted at 55 inches above the finished floor.

TR5

6 months

4.3. b   The fax machine is inaccessible because the controls are mounted at 48.5 inches above the finished floor with 12 inches of obstruction to feed the paper into the back of the machine.

TR4

6 months

4.4     Fitness Area-Room 140

   

4.4. a   The clean peroxy spray is inaccessible because the control is mounted at 61 inches above the finished floor.

TR5

6 months

4.5     Drinking Fountains

   

4.5. a   Near Main Counter in Lobby

   

4.5. a (1)  The drinking fountain is inaccessible because the water flow is 3 inches high and the control requires 10 lbf to operate.

DF1

6 months

4.5. b   Fitness Center Drinking Fountain

   

4.5. b (1) The drinking fountain is inaccessible because the water flow is 3 inches high and the control requires 10 lbf to operate.

DF1

6 months

4.5. c   Lower Level Drinking Fountains near Women's Locker Room, Family Side of Pool, and Training Side of Pool

   

4.5. c (1)  The walkway is inaccessible because the higher drinking fountain in each of these three areas protrudes into the walkway and would not be detectable to a blind person using a cane.

AR8

6 months

4.6     Men's Toilet Room on Main Level

   

4.6. a   The toilet room door is inaccessible because the pressure required to open the door is 8 pounds.

D2

6 months

4.6. b   The walkway is inaccessible because the baby changing station and the lavatory protrude into the walkway and would not be detectable to a blind person using a cane.

AR8

6 months

4.6. c   No accessible coat hook has been provided.

TR1

6 months

4.6. d   The toilet paper dispenser is inaccessible because the distance to the rear wall is 38 inches.

ST19

6 months

4.7     Women's Toilet Room on Main Level

   

4.7. a   The toilet room door is inaccessible because the pressure required to open the door is 8 pounds.

D2

6 months

4.7. b   The walkway is inaccessible because the baby changing station and lavatory protrude into the walkway and would not be detectable to a blind person using a cane.

AR8

6 months

4.7. c   The sanitary napkin dispenser is inaccessible because it requires tight grasping and twisting of the wrist to operate.

TR3

6 months

4.7. d   No accessible coat hook has been provided.

TR1

6 months

4.8     Elevator

   

4.8. a   The elevator is inaccessible because the hall call button is centered at 40.5 inches above the finished floor. 

E3

6 months

4.9     Multipurpose Rooms 1 and 2 (Rooms 130 and 132)

   

4.9. a   The signage provided is inaccessible because it is not on the latch side of the door.

D26

6 months

4.10   Party Room-Room 019

   

4.10. a The signage provided is inaccessible because it is not on the latch side of the door.

D26

6 months

4.11   Aquatics Office-Room 012

   

4.11. a The signage provided is inaccessible because it is not on the latch side of the door. 

D26

6 months

4.11. b The pull side of the door to the Aquatics Office, which is accessed through a front approach, is inaccessible because it is obstructed by a cabinet.

D6

6 months

4.12   Single User Toilet and Shower Rooms ("Family Changing Rooms") on Women's Side

   

4.12. a No accessible coat hook has been provided.

TR1

6 months

4.12. b No accessible mirror has been provided.

TR14

6 months

4.12. c The rear grab bar at the toilet is inaccessible because the closer end is 7 inches from the side wall.

SU2

6 months

4.12. d The shower spray unit is inaccessible because it is mounted approximately 70 inches from the floor, cannot be used as both a fixed and hand held shower, and the shower hose length does not comply with the Standards.

B8

6 months

4.12. e The bench is inaccessible because it is 16 inches above the finished floor and 18 inches wide.

LR1

6 months

4.12. f There are no accessible lockers provided in each Family Changing Room.

LR3

6 months

4.13   Pool Area (Family Side)

   

4.13. a There is no accessible locker provided.

LR3

6 months

4.14   Single User Toilet Room-Family Changing Room on Men's Side

   

4.14. a No accessible coat hook has been provided.

TR1

6 months

4.14. b No accessible mirror has been provided.

TR14

6 months

4.14. c The rear grab bar at the toilet is inaccessible because the distance from the closer end to the side wall is 8 inches.

SU2

6 months

4.14. d There is no accessible locker provided.

LR3

6 months

4.15   Women's Locker Room (Lower Level)

   

4.15. a The entry door is inaccessible because the pressure required to open the door is 8 pounds.

D2

6 months

4.15. b The walkway is inaccessible because the air dryer protrudes into the walkway and would not be detectable to a blind person using a cane.

AR8

6 months

4.15. c No accessible coat hook has been provided.

TR1

6 months

4.15. d The benches in the women's locker room are inaccessible because they are 16 inches above the finished floor and 18 inches wide.

LR1

6 months

4.15. e There is no accessible locker provided.

LR3

6 months

4.16   Men's Locker Room

   

4.16. a The entry door is inaccessible because the pressure required to open the door is 8 pounds.

D2

6 months

4.16. b The walkway is inaccessible because the air dryer protrudes into the walkway and would not be detectable to a blind person using a cane.

AR8

6 months

4.16. c No accessible coat hook has been provided.

TR1

6 months

4.16. d The shower in the men's locker room is inaccessible because the shower spray unit cannot be used as both fixed and hand-held and the shower head is higher than 48 inches above the finished floor.

B11

6 months

4.16. e The benches in the men's locker room are inaccessible because they are 16 inches above the finished floor and 18 inches wide.

LR1

6 months

4.16. f There is no accessible locker provided.

LR3

6 months

5.   Chantilly Regional Library

      4000 Stringfellow Road        

      Chantilly, VA 20151

   

5.1     Parking

   

5.1. a   The van parking reserved for persons with disabilities is not located on the shortest accessible route to the accessible facility entrance.

P5

6 months

5.1. b   The parking reserved for persons with disabilities is inaccessible because the slopes and cross slopes of several of the parking spaces and adjacent access aisles exceed 2%. 

P7

6 months

5.2     Accessible Route

   

5.2. a   The route from the four designated accessible parking spaces located closest to the employee entrance is inaccessible because the slope of the curb ramp is 11.3%.

AR5

6 months

5.2. b   The route from the van accessible parking to the public entrance is inaccessible because  the route has a cross slope of 3.8% near the employee entrance.

AR1

6 months

5.2. c   The route from the four curb ramps leading to the public entrance from the five closest designated accessible parking spaces is inaccessible because the slope of the four curb ramps range from 16.1% to 17.7% and the flared sides range from 35.1% to 58.5%. 

AR5

6 months

5.3     Public Pay Telephone in Entrance Vestibule

   

5.3. a   The telephone is inaccessible because it is not hearing aid compatible.

TT1

6 months

5.4     Public Meeting Room Corridor

   

5.4. a   Some doors in the corridor are inaccessible because knob hardware is used.

D1

6 months

5.5     Public Meeting Room

   

5.5. a   No accessible coat hook has been provided.

TR1

6 months

5.6     Public Conference Room

   

5.6. a   The walkway is inaccessible because the coat rack, which is 62.5 inches above the finished floor to the lower hanger and protrudes 15.5 inches into the walkway, would not be detectable to a blind person using a cane.

AR8

6 months

5.6. b   No accessible coat hook has been provided.

TR1

6 months

5.7     Women's Public Toilet Room with Stalls

   

5.7. a   The toilet room sign for the women's room is inaccessible because it is not mounted on the latch side of the door, the centerline is 59.5 inches, and the sign does not have Braille characters.

TR18

6 months

5.7. b   The women's room door is inaccessible because the pressure required to open the door is 10 pounds.

D2

6 months

5.7. c   The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact.

TR12

6 months

5.7. d   The toilet room stall is inaccessible because the door swings into the required clear floor space at the air dryer and seat cover dispenser.

TR6

6 months

5.7. e   The toilet in the designated accessible stall is inaccessible because the top of the seat is 19.5 inches above the finished floor.

ST20

6 months

5.7. f   No accessible coat hook has been provided in the designated accessible stall.

TR1

6 months

5.7. g   The toilet paper dispenser in the designated accessible stall is inaccessible because the dispenser is more than 36 inches from the rear wall.

ST19

6 months

5.7. h   The side grab bar at the toilet in the designated accessible stall is inaccessible because the distance from the farther end to the rear wall is less than 52 inches.

ST7

6 months

5.8     Men's Public Toilet Room with Stalls

   

5.8. a   The toilet room sign for the men's room is inaccessible because it is not mounted on the latch side of the door, the centerline is 59.5 inches, and the sign does not have Braille characters.

TR18

6 months

5.8. b   The toilet room door is inaccessible because the pressure required to open the door is 10 pounds.

D2

6 months

5.8. c   The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact.

TR12

6 months

5.8. d   The toilet room stall is inaccessible because the door swings into the required clear floor space at the air dryer.

TR6

6 months

5.8. e   The walkway is inaccessible because the air dryer protrudes into the walkway and would not be detectable to a blind person using a cane. 

AR8

6 months

5.8. f   The toilet in the designated accessible stall is inaccessible because the flush control is on the closed side.

ST2

6 months

5.8. g   No accessible coat hook has been provided in the designated accessible stall.

TR1

6 months

5.8. h   The toilet paper dispenser in the designated accessible stall is inaccessible because the dispenser is 40 inches from the rear wall.

ST19

6 months

5.8. i   The side grab bar at the toilet in the designated accessible stall is inaccessible because the distance from the farther end to the rear wall is 48 inches.

ST7

6 months

5.9     Public Corridor Drinking Fountain

   

5.9. a   Although two drinking fountains are provided, there is no accessible drinking fountain because the spout on the lower fountain is 3.5 inches from the front edge and the water flow is not within 3 inches of the front edge.

DF1

6 months

5.10   Library

   

5.10. a The check-out area is inaccessible because the accessible portion of the check out counter is blocked by objects and not utilized as a counter.

L2

6 months

5.10. b The walkway is inaccessible because the defibrillator near the counter, which is mounted 55 inches above the finished floor and 6 inches deep, protrudes into the walkway and would not be detectable to a blind person using a cane.

AR8

6 months

5.11   Library Employee Area

   

5.11. a The route to an office in the employee work area is inaccessible because it narrows to 30 inches wide because of stacked boxes.

AR3

6 months

5.12   Employee Technical Operations Computer Server Area

   

5.12. a The entry door is inaccessible because knob hardware is used.

D1

6 months

5.13   Employee Toilet Rooms with Stalls near Employee Entrance

   

5.13. a Men's Toilet Room

   

5.13. a (1)      The toilet room sign is inaccessible because it is not mounted on the latch side of the door.

TR18

6 months

5.13. a (2)      The men's room door is inaccessible because the pressure required to open the door is 7 pounds.

D2

6 months

5.13. a (3)      The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact.

TR12

6 months

5.13. a (4)      The urinal is inaccessible because the rim is 18 inches above the finished floor and the clear floor space in front of the urinal is 29 inches wide.

TR20

6 months

5.13. a (5)      No accessible coat hook has been provided.

TR1

6 months

5.13. a (6)      The toilet paper dispenser is inaccessible because the dispenser is 37 inches from the rear wall.

ST19

6 months

5.13. b Women's Toilet Room

   

5.13. b (1)     The toilet room sign is inaccessible because it is not mounted on the latch side of the door.

TR18

6 months

5.13. b (2)     The toilet room door is inaccessible because the pressure required to open the door is 8 pounds.

D2

6 months

5.13. b (3)     The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact.

TR12

6 months

5.13. b (4)     The toilet room stall is inaccessible because the door swings into the required clear floor space at the seat cover dispenser.

TR6

6 months

5.13. b (5)     The toilet is inaccessible because its centerline measures 17 inches from the side wall.

ST17

6 months

5.13. b (6)     The toilet is inaccessible because the flush control is on the closed side. 

ST2

6 months

5.13. b (7)     No accessible coat hook has been provided.

TR1

6 months

5.13. b (8)     The toilet paper dispenser is inaccessible because the dispenser is 41 inches from the rear wall.

ST19

6 months

5.14   Hallway near Employee Toilet Rooms with Stalls

   

5.14. a The walkway is inaccessible because the defibrillator near the toilet rooms, which is mounted 55 inches above the finished floor and is 6 inches deep, protrudes into the walkway and would not be detectable to a blind person using a cane.

AR8

6 months

5.15   Technical Operations Center

   

5.15. a Staff Training Room

   

5.15. a (1)      The route within the training room is inaccessible because it is 24 inches wide in one area.

AR3

6 months

5.15. a (2)      No accessible coat hook or rack has been provided.

TR1

6 months

5.16   Employee Single User Toilet Rooms Located in the Vestibule Between Employee Area and Technical Operations Area

   

5.16. a Men's Room

   

5.16. a (1)      The signage provided is inaccessible because it is mounted on the door and centered at 61 inches above the finished floor.

TR18

6 months

5.16. a (2)      No accessible coat hook has been provided.

TR1

6 months

5.16. a (3)      The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact.

TR12

6 months

5.16. a (4)      The toilet is inaccessible because the top of the seat is 19.5 inches above the finished floor.

SU18

6 months

5.16. a (5)      The toilet is inaccessible because its centerline measures 17 inches from the side wall.

SU15

6 months

5.16. a (6)      The toilet is inaccessible because the flush control is on the closed side.

SU1

6 months

5.16. a (7)      The toilet paper dispenser is inaccessible because it is located 41 inches from the rear wall.

SU17

6 months

5.16. b Women's Room

   

5.16. b (1)     The signage provided is inaccessible because it is mounted on the door and centered at 61 inches above the finished floor.

TR18

6 months

5.16. b (2)     No accessible coat hook has been provided.

TR1

6 months

5.16. b (3)     The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact.

TR12

6 months

5.16. b (4)     The toilet paper dispenser is inaccessible because it is located 41.5 inches from the rear wall.

SU17

6 months

5.17   Staff Kitchen/Lounge (near single-user toilet rooms)

   

5.17. a The staff lockers are inaccessible because they operate by key which requires tight grasping and twisting of the wrist.

LR3

6 months

6.   Jennings Judicial Center Public Parking Garage B

      10550 Page Avenue

      Fairfax, Va 22030

   

6.1     Although there are 7 floors for public parking with 1213 spaces, there are only 14 designated accessible spaces, none of which are van accessible.

P3

6 months

7.   Mott Community Center

      12111 Braddock Road

      Fairfax, VA 22030

   

7.1     Parking

   

7.1. a   The parking reserved for persons with disabilities is inaccessible because the seven designated accessible parking spaces and access aisles have slopes and cross slopes exceeding  2%.

P7

6 months

7.2     Accessible Route

   

7.2. a   The route from the van accessible space next to the building to the entrance is inaccessible because the curb ramp has a primary slope of  10.1% and a cross slope of 6.8%.

AR5

6 months

7.3     Gymnasium

   

7.3. a   The door to the gymnasium is inaccessible because the pressure required to open the door is 11 pounds.

D2

6 months

7.3. b   The gymnasium is inaccessible to people with hearing impairments because there is no assistive listening system.

AA5

6 months

7.4     Main Lobby

   

7.4. a   The service counter at is inaccessible because it is 42 inches above the finished floor.

C6

6 months

7.4. b   The walkway is inaccessible because the display case located between Rooms 1 and 2 protrudes into the walkway and would not be detectable to a blind person using a cane.

AR8

6 months

7.5     Rooms 1, 2, and 3

   

7.5. a   The door to each room is inaccessible because the pressure required to open the door is more than 5 pounds.

D2

6 months

7.6     Room 1

   

7.6. a   The service counters in the kitchen area in this room are inaccessible because they are 37 inches above the finished floor.

C8

6 months

7.7     Public Pay Telephone

   

7.7. a   The telephone is inaccessible because the clear floor space is blocked by a chair. 

TT1

6 months

7.8     Drinking Fountain near Toilet Rooms

   

7.8. a   The walkway is inaccessible because the lower drinking fountain protrudes into the walkway and would not be detectable to a blind person using a cane.

AR8

6 months

7.9     Men's Toilet Room

   

7.9. a   The toilet room sign is inaccessible because it is on the hinge side of the door.

TR18

6 months

7.9. b   The door to the toilet room is inaccessible because the pressure required to open the door is 11 pounds.

D2

6 months

7.9. c   The toilet is inaccessible because the flush control is on the closed side.

ST2

6 months

7.9. d   No accessible coat hook has been provided.

TR1

6 months

7.10   Women's Toilet Room

   

7.10. a The toilet room sign is inaccessible because it is on the hinge side of the door.

TR18

6 months

7.10. b The door to the toilet room is inaccessible because the pressure required to open the door is 9 pounds.

D2

6 months

7.10. c The sanitary napkin dispenser is inaccessible because the operating mechanism requires tight grasping and twisting of the wrist.

TR3

6 months

7.10. d The toilet is inaccessible because its centerline measures 19 inches from the side wall.

ST17

6 months

7.10. e No accessible coat hook has been provided.

TR1

6 months

7.10. f The toilet paper dispenser is inaccessible because the distance to the rear wall is 40 inches.

ST19

6 months

7.11   Outdoor Route to Exterior Amenities-Play Area, Benches, Picnic Tables, Basketball Court

   

7.11. a The route from the entrance to the outdoor amenities is inaccessible because the route slopes up to 16.1%.

AR1

6 months

7.11. b None of the play equipment is usable by children with disabilities.

PG1

6 months

7.11. c The picnic tables are inaccessible because none provide the required knee space. 

PD6

6 months

8.   Boys Probation House

      4410 Shirley Gate Road

      Fairfax, VA 22030

   

8.1     Accessible Route

   

8.1. a   The route from the parking lot to the entrance is inaccessible because the curb ramp at the accessible parking space has a primary slope of 9.1% and there is no level landing at the top of the ramp.

AR5

6 months

8.1. b   The curb ramp near the front entrance is inaccessible because the primary slope of the curb ramp is 11.3%.

AR5

6 months

8.2     Interview Room

   

8.2. a   The push side of the door to the interview room, which is accessed through a front approach and which has both a closer and a latch, is inaccessible because it has only 3 inches of clearance as a chair blocks the clear floor space.

D7

6 months

8.3     Laundry Room

   

8.3. a   The laundry room is inaccessible because the laundry room door swings into the required clear floor space at the washer/dryer.

TR6

6 months

8.3. b   The washer and dryer are inaccessible because the controls are mounted at the back of the machine.

TR4

6 months

8.3. c   The laundry room sink is inaccessible because the hardware requires tight grasping and twisting of the wrist and there is not adequate clear floor space.

TR9

6 months

8.4     Learning Center

   

8.4. a   The walkway is inaccessible because the foosball table operating levers protrude into the walkway and would not be detectable to a blind person using a cane.

AR8

6 months

8.4. b   The sink is inaccessible because the pipes are not wrapped and the clear floor space under it is obstructed.

TR9

6 months

8.4. c   The walkway is inaccessible because the lower drinking fountain protrudes into the walkway and would not be detectable to a blind person using a cane.

AR8

6 months

8.5     Classroom A

   

8.5. a   The computer work station is inaccessible because it is 26 inches above the finished floor.

C3

6 months

8.6     Classroom C

   

8.6. a   The study tables are inaccessible because the tables are 26 inches above the finished floor and do not provide adequate knee space height.

T1

6 months

8.7     Women's Single User Toilet Room with Shower in Hallway

   

8.7. a   The toilet room door is inaccessible because the pressure required to open the door is 12 pounds.

D2

6 months

8.7. b   No accessible mirror has been provided.

TR14

6 months

8.7. c   The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact.

TR12

6 months

8.8     Men's Single User Toilet Room with Bathtub in Hallway

   

8.8. a   The toilet room door is inaccessible because the pressure required to open the door is 12 pounds.

D2

6 months

8.8. b   No accessible mirror has been provided.

TR14

6 months

8.8. c   The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact.

TR12

6 months

8.9     Drinking Fountain next to Men's Toilet Room

   

8.9. a   The walkway is inaccessible because the lower drinking fountain protrudes into the walkway and would not be detectable to a blind person using a cane.

AR8

6 months

8.10   Boys Transitional Housing Unit

   

8.10. a Single User Toilet Room with Shower

   

8.10. a (1)      The door is inaccessible because there is no signage on latch side of door.

TR18

6 months

8.10. a (2)      The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact.

TR12

6 months

8.10. a (3)      The toilet is inaccessible because the flush control is on the closed side. 

SU1

6 months

8.11   Double Resident Room

   

8.11. a The route near the beds is inaccessible because it is only 23 inches wide.

AR3

12 months

8.12   Drinking Fountains

   

8.12. a The walkway is inaccessible because the lower drinking fountains by the men's toilet room and by the learning center protrude into the walkway and would not be detectable to a blind person using a cane.

AR8

6 months

8.13   Public Pay Telephones in Hallway near Men's Toilet Room

   

8.13. a The telephones in the hallway are inaccessible because the counter height is 26.5 inches, the knee space height is 25 inches and width is 27 inches, and there is no accessible signage.

TT1

6 months

8.14   Boys Therapeutic Housing Unit

   

8.14. a The single user toilet room with shower contains a number of inaccessible elements and is not accessible to people with disabilities.

B8, SU13

6 months

8.14. b There is no accessible sleeping room for double occupants.

H4,H9

6 months

9.   Great Falls Library

      9830 Georgetown Pike

      Great Falls, VA 22066

   

9.1     Parking

   

9.1. a   The parking reserved for persons with disabilities is inaccessible because the space closest to the park is obstructed by the trash receptacle.

P8

6 months

9.2     Drinking Fountain near Toilet Rooms

   

9.2. a   The walkway is inaccessible because the high drinking fountain protrudes into the walkway and would not be detectable to a blind person using a cane.

AR8

6 months

9.3     Toilet Rooms with Stalls

   

9.3. a   Women's Room

   

9.3. a (1)  The toilet room sign is inaccessible because it is mounted with its centerline  57 inches above the finished floor.

TR18

6 months

9.3. b   Men's Room

   

9.3. b (1) The toilet room sign is inaccessible because it is mounted with its centerline  57 inches above the finished floor.

TR18

6 months

9.4     Employee Single User Toilet Room

   

9.4. a   No accessible mirror has been provided.

TR14

6 months

10. Herndon Fortnightly Library

      768 Center Street

      Herndon, VA 20170

   

10.1   Accessible Route

   

10.1. a The ramp to the entrance is inaccessible because the handrails do not have 12 inch extensions at the top and bottom of the run.

R4

6 months

10.2   First Floor Women's Toilet Room with Stalls

   

10.2. a The toilet room sign is inaccessible because it does not have a centerline of 60 inches.

TR18

6 months

10.2. b The toilet room door is inaccessible because the pressure required to open the door is 15 pounds.

D2

6 months

10.2. c The pull side of the door to the toilet room, which is accessed from the hinge side of the door, is inaccessible because it has only 31 inches of width for maneuvering clearance.

D8

6 months

10.2. d The seat cover dispenser is inaccessible because the entrance door swings into the required clear floor space at the seat cover dispenser.

TR6

6 months

10.2. e The lavatory is inaccessible because the bottom edge of the apron is 28 inches above the finished floor.

TR11

6 months

10.2. f The toilet is inaccessible because its centerline measures 17 inches from the side wall. 

ST17

6 months

10.2. g The side grab bar at the toilet is inaccessible because the distance from the farther end to the rear wall is 49 inches.

ST7

6 months

10.2. h The rear grab bar at the toilet is inaccessible because the overall length is 33.5 inches.

ST4

6 months

10.3   First Floor Men's Toilet Room with Stalls

   

10.3. a The toilet room sign is inaccessible because it does not have a centerline of 60 inches.

TR18

6 months

10.3. b The toilet room door is inaccessible because the pressure required to open the door is 17 pounds.

D2

6 months

10.3. c The pull side of the door to the toilet room, which is accessed from the hinge side of the door, is inaccessible because it has only 31 inches of width for maneuvering clearance.

D8

6 months

10.3. d The urinal is inaccessible because the clear floor space is 28 inches wide.

TR20

6 months

10.3. e The side grab bar at the toilet is inaccessible because the distance from the farther end to the rear wall is 49 inches.

ST7

6 months

10.3. f The rear grab bar at the toilet is inaccessible because the overall length is 34 inches. 

ST4

6 months

10.3. g No accessible coat hook has been provided.

TR1

6 months

10.4   Elevator

   

10.4. a The elevator is inaccessible because hoistway signage is centered at 58 inches above the finished floor.

E12

6 months

10.5   Second Floor Magazine Display

   

10.5. a The magazine display is inaccessible because the highest rack is 69 inches above the finished floor.

L1

6 months

10.6   Second Floor Employee Single User Toilet Room

   

10.6. a The toilet room sign is inaccessible because it has a centerline of 54 inches.

TR18

6 months

10.6. b No accessible mirror has been provided.

TR14

6 months

10.6. c The side grab bar at the toilet is inaccessible because the distance from the farther end to the rear wall is 48 inches.

ST7

6 months

10.6. d The rear grab bar at the toilet is inaccessible because the overall length is 30 inches. 

ST4

6 months

10.7   Second Floor Rear Entrance Door

   

10.7. a The door is inaccessible because there is a .75 inch change in level at the threshold to the door.

D22

6 months

10.8   Second Floor Women's Toilet Room

   

10.8. a The toilet room sign is inaccessible because it has a centerline of 56 inches.

TR18

6 months

10.8. b The toilet room door is inaccessible because the pressure required to open the door is more than 5 pounds.

D2

6 months

10.8. c No accessible coat hook has been provided.

TR1

6 months

10.8. d The side grab bar at the toilet is inaccessible because the distance from the farther end to the rear wall is 48.5 inches.

ST7

6 months

10.8. e The rear grab bar at the toilet is inaccessible because the overall length is 33.5 inches. 

ST4

6 months

10.9   Second Floor Men's Toilet Room

   

10.9. a The toilet room sign is inaccessible because it has a centerline of 56 inches.

TR18  

6 months

10.9. b The toilet room door is inaccessible because the pressure required to open the door is 17 pounds.  Provide a door that requires no more than 5 pounds of force to open.  Standards §§ 4.1.3(7)(b), 4.13.11(2)(b).

D2

6 months

10.9. c No accessible coat hook has been provided.

TR1

6 months

10.9. d The side grab bar at the toilet is inaccessible because the distance from the farther end to the rear wall is 48 inches.

ST7

6 months

10.9. e The rear grab bar at the toilet is inaccessible because the overall length is 34 inches.

ST4

6 months

10.10 Second Floor Drinking Fountains near Toilet Rooms

   

10.10. a     The wall-mounted drinking fountain is inaccessible because the knee clearance is 26.25 inches high.

DF5

6 months

10.10. b     The walkway is inaccessible because the high drinking fountain protrudes into the walkway and would not be detectable to a blind person using a cane.

AR8

6 months

11. Herndon Senior Center

      873 Grace Street        

      Herndon, VA 20170

   

11.1   Parking

   

11.1. a The parking reserved for persons with disabilities is not located on the shortest accessible route to the accessible facility entrance.

P5

6 months

11.1. b The parking reserved for persons with disabilities is inaccessible because the designated spaces and access aisles have slopes and cross slopes ranging from 3.7% to 4.7%. 

P7

6 months

11.2   Accessible Route

   

11.2. a The route from the accessible parking to the entrance is inaccessible because as the route curves the cross slope reaches 2.7%.

AR1

6 months

11.2. b The passenger loading zone is inaccessible because it is not marked as such.

P4

6 months

11.3   First Floor

   

11.3. a Toilet Rooms with Stalls (located to the right of the entrance)

   

11.3. a (1)    Women's Room

   

(a)   The toilet room door is inaccessible because the pressure required to open the door is 15 pounds.

D2

6 months

(b)  The lavatory is inaccessible because the apron is 27.25 inches above the finished floor.

TR11

6 months

11.3. a (2)    Men's Room

   

(a)   The toilet room door is inaccessible because the pressure required to open the door is 15 pounds.

D2

6 months

(b)  The lavatory is inaccessible because the apron is 27.25 inches above the finished floor.

TR11

6 months

11.3. b Drinking Fountain adjacent to Toilet Rooms

   

11.3. b (1)    The walkway is inaccessible because the high drinking fountain protrudes into the walkway and would not be detectable to a blind person using a cane.

AR8

6 months

11.3. c Employee Single User Toilet Room (near elevator)

   

11.3. c (1)    The toilet is inaccessible because its centerline measures 19 inches from the side wall.

SU15

6 months

11.3. c (2)    The toilet paper dispenser is inaccessible because the distance to the rear wall is 37.5 inches.

SU17

6 months

11.4   Second Floor Display Rack

   

11.4. a The display rack containing pamphlets and bus schedules is inaccessible because it is 58 inches to the highest area.

L1

6 months

11.5   Second Floor Toilet Rooms

   

11.5. a Women's Room

   

11.5. a (1)    The toilet room door is inaccessible because the pressure required to open the door is 17 pounds.

D2

6 months

11.5. a (2)    The lavatory is inaccessible because the apron is 27.25 inches above the finished floor.

TR11

6 months

11.5. b Men's Room

   

11.5. b (1)    The toilet room door is inaccessible because the pressure required to open the door is 13 pounds.

D2

6 months

11.5. b (2)    The entrance to the toilet room is inaccessible because there is only 38 inches of maneuvering clearance in the vestibule between the doors.

D3

6 months

11.5. b (3)    The lavatory is inaccessible because the apron is 27.50 inches above the finished floor.

TR11

6 months

11.6   Second Floor Drinking Fountain near Toilet Rooms

   

11.6. a Although one drinking fountain is provided, there is no accessible drinking fountain.

DF1

6 months

11.7   Second Floor Housing Management Office

   

11.7. a The service counter is inaccessible because it is 42 inches above the finished floor.

C6

6 months

11.8   Second Floor Single User Toilet Room (Housing Management Office)

   

11.8. a The toilet is inaccessible because its centerline measures 17 inches from the side wall. 

SU15

6 months

11.8. b The toilet paper dispenser is inaccessible because the distance to the rear wall is 37 inches.

SU17

6 months

12. Clemyjontri Park

      6317 Georgetown Pike

      McLean, VA 22101

   

12.1   Parking

   

12.1. a The parking reserved for persons with disabilities is inaccessible because the designated van space farthest to the right has a slope of 3.3%.

P7

6 months

12.1. b The parking reserved for persons with disabilities is inaccessible because several of the designated van accessible access aisles are too narrow.

P8

6 months

12.2   Accessible Routes

   

12.2. a The route from the loading zone to the closest playground is inaccessible because it has a slope of up to 5.5% and the pavers are not stable, firm and slip resistant.

AR1

6 months

12.2. b The route to the picnic area and shelter closest to the parking and toilet room is inaccessible because it has a slope of up to 7.7%, cross slope of up to 3.5%, and the route to the area using the pavers is not stable, firm and slip resistant.

AR1

6 months

12.2. c The designated accessible picnic table is inaccessible because the cut out area for a wheelchair is only 23.5 inches wide.

PD6

6 months

12.2. d The route is inaccessible because the clearance between the carousel platform and the edge of the accessible route is 3 inches.

AR1

AR6

6 months

12.3   Playground

   

12.3. a The walkway is inaccessible because there are various playground area elements which protrude into the walkway and would not be detectable to a blind person using a cane.

AR8

6 months

12.4   Drinking Fountain Near Toilet Rooms

   

12.4. a Although two drinking fountains are provided, there is no accessible drinking fountain because the water flow height is less than 4 inches and the controls require 15 lbf to operate.

DF1

6 months

12.5   Women's Toilet Room with Stalls

   

12.5. a The side grab bar at the toilet is inaccessible because the distance of the closer end to the rear wall is 13.5 inches.

ST7

6 months

12.5. b The rear grab bar at the toilet is inaccessible because the distance of the closer end to the rear wall is 7.5 inches and the grab bar is mounted 36.5 inches above the floor.

ST3

6 months

12.6   Men's Toilet Room with Stalls

   

12.6. a The side grab bar at the toilet is inaccessible because the distance of the closer end to the rear wall is 13.5 inches and the grab bar is mounted 36.5 inches above the floor.

ST7

6 months

12.6. b The toilet is inaccessible because its centerline measures 19.25 inches from the side wall.

ST17

6 months

13. Reston Community Center-Hunter Woods

      2310 Colts Neck Road

      Reston, VA 20190

   

13.1   Drinking Fountain Near Toilet Rooms

   

13.1. a The drinking fountain is inaccessible because it has a spout that is 38 inches above the finished floor.

DF6

6 months

13.2   Men's Toilet Room With Stalls Near Entrance

   

13.2. a Although an audible alarm is provided in this facility, there is no visual alarm appliance in the toilet room.

TR21

6 months

13.2. b The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact.

TR12

6 months

13.2. c There is no standard accessible stall provided.

ST15

6 months

13.3   Women's Toilet Room With Stalls Near Entrance

   

13.3. a Although an audible alarm is provided in this facility, there is no visual alarm appliance in the toilet room.

TR21

6 months

13.3. b The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact.

TR12

6 months

13.3. c There is no standard accessible stall provided.

ST15

6 months

13.4   Theater

   

13.4. a The double doors to the theater are inaccessible because the door leaf width is 29 inches.

D17

6 months

13.4. b The theater containing 290 seats is inaccessible because only two of the four seating areas reserved for wheelchair users have a companion seat.

AA6

6 months

13.4. c The theater is inaccessible because it lacks fixed aisle seating without armrests.

AA2   

6 months

13.4. d The theater is inaccessible becuase there is no signage informing the public of the availability of an assistive listening system.

AA3

6 months

13.5   Designated Route To Theater Stage Through Lobby And Other Areas

   

13.5. a Ramp To Dance Studio

   

13.5. a (1)    The ramp is inaccessible because there is no edge protection.

R1

6 months

13.5. a (2)    The ramp is inaccessible because the handrails are 32 inches above the walking surface, the inside handrail is not continuous, and there are no handrail extensions.

R2

6 months

13.6   Men's and Women's Toilet Rooms With Stalls on the Main Floor Near the Rear Entry

   

13.6. a Each toilet room door is inaccessible because the pressure required to open the door is more than 5 pounds.

D2

6 months

13.6. b Although an audible alarm is provided in this facility, there is no visual alarm appliance in either toilet room.

TR21

6 months

13.6. c There is no standard accessible stall provided.

ST15

6 months

13.7   Drinking Fountain On Main Floor Near Rear Toilet Rooms

   

13.7. a The drinking fountain is inaccessible because it has a spout that is 39 inches above the finished floor.

DF6

6 months

13.8   Elevator

   

13.8. a The elevator is inaccessible because the hall lanterns do not have audible and visual signals.

E11

6 months

13.8. b The elevator is inaccessible because the hoistway signage is mounted at 44 inches above the finished floor.

E12

6 months

13.8. c The elevator is inaccessible because the door does not reopen automatically if obstructed.

E6

6 months

13.8. d The elevator is inaccessible because the car measures 63 x 58 inches.

E2

6 months

13.8. e The clearance between the car platform sill and the edge of the hoistway landing is 1.5 inches.

E10

6 months

13.8. f The elevator is inaccessible because the car position is not indicated by illumination or auditory cue when it passes or stops on a floor.

E5

6 months

13.9   Lower Level-Pool

   

13.9. a Lobby Counter

   

13.9. a (1)    The service counter at the pool is inaccessible because it is 42 inches above the finished floor.

C6

6 months

13.9. b Women's Locker Room

   

13.9. b (1)    The signage provided is inaccessible because it is not mounted on the latch side of the door at 60 inches to the centerline above the finished floor and it has no Braille or raised characters.

D26

6 months

13.9. b (2)    The locker room door is inaccessible because the pressure required to open the door is more than 5  pounds.

D2

6 months

13.9. b (3)    The air dryer is inaccessible because the controls are mounted at 59 inches above the finished floor.

TR5

6 months

13.9. b (4)    The walkway is inaccessible because the air dryer protrudes into the walkway and would not be detectable to a blind person using a cane.

AR8

6 months

13.9. b (5)    There is no standard accessible stall provided.

ST15

6 months

13.9. b (6)    The roll-in shower in the locker room is inaccessible because the seat does not fold, the seat is 22 inches above the finished floor, the clear floor space is 58 x 59 inches and the grab bars are L-shaped.

B8

6 months

13.9. b (7)    The bench in the locker room is inaccessible because it is 18 inches wide and 20 inches above the finished floor.

LR1

6 months

13.9. b (8)    There is no accessible locker provided.

LR3

6 months

13.9. c Men's Locker Room

   

13.9. c (1)    The signage provided is inaccessible because it is not mounted on the latch side of the door at 60 inches to the centerline above the finished floor and it has no Braille or raised characters.

D26

6 months

13.9. c (2)    The toilet room door is inaccessible because the pressure required to open the door is more than 5  pounds.

D2

6 months

13.9. c (3)    The lavatory is inaccessible because the rim is 35 inches above the finished floor.

TR11

6 months

13.9. c (4)    The air dryer is inaccessible because the controls are mounted at 59 inches above the finished floor.

TR5

6 months

13.9. c (5)    The walkway is inaccessible because the air dryer protrudes into the walkway and would not be detectable to a blind person using a cane.

AR8

6 months

13.9. c (6)    The toilet paper dispenser in the designated accessible stall is inaccessible because the distance to the rear wall is more than 36 inches.

ST19

6 months

13.9. c (7)    The side grab bar at the toilet in the designated accessible stall is inaccessible because distance to the rear wall is less than 52 inches and the height of the grab bar is not 33 to 36 inches above the finished floor.

ST6

6 months

13.9. c (8)    The roll-in shower in the locker room is inaccessible because the seat does not fold, the seat is 22 inches above the finished floor, there is inadequate clear floor space and there are no grab bars.

B8

6 months

13.9. c (9)    No accessible mirror has been provided.

TR14

6 months

13.9. c (10)  The bench in the locker room is inaccessible because it does not meet the minimum requirements for height and width.

LR1

6 months

13.9. c (11)  There is no accessible locker provided.

LR3

6 months

13.10 Pool Area

   

13.10. a     The jacuzzi is not accessible to people with disabilities because it does not have an accessible route with a transfer platform to enable people who use wheelchairs to use it.

AR2

6 months

13.10. b     Although an accessible pool side drinking fountain is provided, there is no drinking fountain provided for people who have difficulty bending or stooping.

DF3

6 months

13.11 Unisex Locker Room

   

13.11. a     The signage provided is inaccessible because there is no International Symbol of Accessibility, no raised character or Braille and the sign is not mounted on the latch side of the door with a centerline of 60 inches to the finished floor.

D26

6 months

13.11. b     No accessible mirror has been provided.

TR14

6 months

13.11. c     The soap dispenser is inaccessible because the controls are mounted at 50 inches above the finished floor over an obstruction.

TR4

6 months

13.11. d     The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact.

TR12

6 months

13.11. e     The toilet is inaccessible because its centerline measures 17 inches from the side wall.

SU15

6 months

13.11. f     The side grab bar at the toilet is inaccessible because the distance from the far end to the rear wall is 50 inches.

SU6

6 months

13.11. g     The rear grab bar at the toilet is inaccessible because it is 25 inches in length.

SU3

6 months

13.11. h     The roll-in shower in the locker room is inaccessible because the seat does not fold, the seat is not located close to the controls, the grab bars are L-shaped and the shower unit is not mounted on a vertical bar.

B8

6 months


 