ATTACHMENT J - Modifications to Altered FacilitiesPlease Note: Paragraph 41 of the Settlement Agreement requires that within three months of the effective date of this Agreement, Denver provide signage as necessary to comply with 28 C.F.R. § 35.163(b), after having surveyed all facilities that are the subject of this Agreement for the purpose of identifying those that have multiple entrances not all of which are accessible. The chart below lists the facilities surveyed by the Department, the access issues identified during the survey, and the actions required to correct the access issues. Required actions are listed using an alphanumeric code. The key to the alphanumeric codes is provided in Attachment M to this Agreement. In order to ensure that the following spaces and elements in Denver’s facilities in which alterations occurred after January 26, 1992, are readily accessible to and usable by persons with disabilities, Denver will take the actions referenced by the alphanumeric code and described in detail in Attachment M to this Settlement Agreement within the time period specified below, which time period will begin to run on the effective date of this Agreement. |
Item # | Access Issue | Completion Date | Remedial Code |
---|---|---|---|
1
|
City / County Building, 1437 Bannock Street |
||
1.1
|
Fourth Floor South Women’s Public Toilet Room: |
||
1.1.1
|
No accessible mirror has been provided. |
6 months |
TR5 |
1.1.2
|
The lavatory water supply and drain pipes are not insulated or otherwise configured to protect against contact. |
9 months |
LS2 |
1.1.3
|
The toilet’s centerline is 27 inches from the side wall. |
18 months |
TR7 |
1.2
|
Fourth Floor South Men’s Public Toilet Room: |
||
1.2.1
|
The lavatory water supply and drain pipes are not insulated or otherwise configured to protect against contact. |
9 months |
LS2 |
1.2.2
|
The toilet’s centerline is 27 inches from the side wall. |
18 months |
TR7 |
1.3
|
Courtroom 414 and Jury Toilet Room: |
||
1.3.1
|
The courtroom has raised jury boxes, judges’ benches, clerk stations, and witness stands with no means of vertical access for persons with disabilities and inadequate maneuvering clearances. |
36 months |
AR1 |
1.3.2
|
The courtroom counsel tables have inadequate clear floor space with forward approach and have inadequate knee clearance. |
36 months |
AR10, C1 |
1.3.3
|
The courtroom does not have any or have inadequate wheelchair seating areas for spectators. |
36 months |
AA6 |
1.3.4
|
The toilet room contains a number of inaccessible elements and is not accessible to people with disabilities. |
36 months |
TR1 |
1.4
|
Drinking Fountain in Jury Room for Courtroom 414: The floor-mounted drinking fountains do not provide adequate knee clearance. |
48 months |
DF4 |
1.5
|
Courtroom 409 and Jury Toilet Room: |
||
1.5.1
|
The courtroom has raised jury boxes, judges’ benches, clerk stations, and witness stands with no means of vertical access for persons with disabilities and inadequate maneuvering clearances. |
48 months |
AR1 |
1.5.2
|
The courtroom counsel tables have inadequate clear floor space with forward approach and have inadequate knee clearance. |
48 months |
AR10, C1 |
1.5.3
|
The courtroom does not have any or have inadequate wheelchair seating areas for spectators. |
48 months |
AA6 |
1.5.4
|
The court room with a built-in sound system, has no portable assistive listening system available and there are no signs indicating the availability elsewhere of assistive listening systems. |
12 months |
AA4 |
1.5.5
|
The toilet room contains a number of inaccessible elements and is not accessible to people with disabilities. |
48 months |
TR1 |
1.6
|
Drinking Fountain in Jury Room for Courtroom 409: The floor-mounted drinking fountains do not provide adequate knee clearance. |
48 months |
DF4 |
1.7
|
Fourth Floor North Women’s Public Toilet Room: |
||
1.7.1
|
No accessible mirror has been provided. |
6 months |
TR5 |
1.7.2
|
The lavatory water supply and drain pipes are not insulated or otherwise configured to protect against contact. |
9 months |
LS2 |
1.8
|
Third Floor Drinking Fountain: The drinking fountain protrudes into the walkway and is not detectable to blind persons using a cane. |
6 months |
AR7 |
1.9
|
Courtroom 376 and Jury Toilet Room: |
||
1.9.1
|
The courtroom has raised judges’ benches and clerk stations with no means of vertical access for persons with disabilities and inadequate maneuvering clearances. |
48 months |
AR1 |
1.9.2
|
The courtroom counsel tables have inadequate clear floor space with forward approach and have inadequate knee clearance. |
48 months |
AR10, C1 |
1.9.3
|
The courtroom does not have any or have inadequate wheelchair seating areas for spectators. |
48 months |
AA6 |
1.9.4
|
There is no signage informing the public of the availability of an assistive listening system. |
6 months |
AA3 |
1.9.5
|
The toilet room contains a number of inaccessible elements and is not accessible to people with disabilities. |
18 months |
TR1 |
1.10
|
Courtroom 368 and Jury Toilet Room: |
||
1.10.1
|
The courtroom has raised jury boxes, judges’ benches, clerk stations, and witness stands with no means of vertical access for persons with disabilities and inadequate maneuvering clearances. |
18 months |
AR1 |
1.10.2
|
The courtroom counsel tables have inadequate clear floor space with forward approach and have inadequate knee clearance. |
6 months |
AR10, C1 |
1.10.3
|
The courtroom does not have any or have inadequate wheelchair seating areas for spectators. |
12 months |
AA6 |
1.10.4
|
The court room with a built-in sound system, has no portable assistive listening system available and there are no signs indicating the availability elsewhere of assistive listening systems. |
12 months |
AA4 |
1.10.5
|
The toilet room contains a number of inaccessible elements and is not accessible to people with disabilities. |
18 months |
TR1 |
1.11
|
Courtrooms 316 and 320: |
||
1.11.1
|
The courtroom counsel tables have inadequate clear floor space with forward approach and have inadequate knee clearance. |
6 months |
AR10, C1 |
1.11.2
|
The courtroom does not have any or have inadequate wheelchair seating areas for spectators. |
12 months |
AA6 |
1.11.3
|
The court room with a built-in sound system, has no portable assistive listening system available and there are no signs indicating the availability elsewhere of assistive listening systems. |
12 months |
AA4 |
1.12
|
Grand Jury Toilet Room 325: |
||
1.12.1
|
The door’s knob hardware requires tight grasping, pinching, or twisting of the wrist to operate. |
6 months |
D2 |
1.12.2
|
No accessible mirror has been provided. |
6 months |
TR5 |
1.12.3
|
The toilet paper dispenser is mounted more than 9” from the front of the toilet. |
6 months |
TR6 |
1.12.4
|
The toilet's flush control is on the closed side. |
18 months |
TR4 |
1.12.5
|
The wall mounted grab bars obstruct the clear floor space provided at the toilet. |
6 months |
TR24 |
1.12.6
|
The side grab bar is mounted with the far end more than 12 inches from the rear wall. |
6 months |
TR17 |
1.12.7
|
There is no rear grab bar provided at the toilet. |
6 months |
TR13 |
1.13
|
Courtroom 309: |
||
1.13.1
|
The courtroom has raised jury boxes, judges’ benches, clerk stations, and witness stands with no means of vertical access for persons with disabilities and inadequate maneuvering clearances. |
48 months |
AR1 |
1.13.2
|
The courtroom does not have any or have inadequate wheelchair seating areas for spectators. |
48 months |
AA6 |
1.13.3
|
There is no signage informing the public of the availability of an assistive listening system. |
6 months |
AA3 |
1.14
|
Courtroom 331: |
||
1.14.1
|
The courtroom has raised judges’ benches, clerk stations, and witness stands with no means of vertical access for persons with disabilities and inadequate maneuvering clearances. |
48 months |
AR1 |
1.14.2
|
The courtroom counsel tables have inadequate clear floor space with forward approach and have inadequate knee clearance. |
48 months |
AR10, C1 |
1.14.3
|
The courtroom does not have any or have inadequate wheelchair seating areas for spectators. |
48 months |
AA6 |
1.14.4
|
There is no signage informing the public of the availability of an assistive listening system. |
6 months |
AA3 |
1.15
|
Third Floor South Men’s Public Toilet Room: |
||
1.15.1
|
The toilet’s flush control is on the closed side. |
18 months |
TR4 |
1.15.2
|
The urinal has a rim that is 22 inches high. |
18 months |
TR8 |
1.16
|
Third Floor North Men’s Public Toilet Room: |
||
1.16.1
|
No accessible mirror has been provided. |
6 months |
TR5 |
1.16.2
|
The lavatory water supply and drain pipes are not insulated or otherwise configured to |
9 months |
LS2 |
1.16.3
|
The paper towel dispenser protrudes into the walkway and is not detectable to blind persons |
6 months |
AR7 |
1.17
|
Third Floor North Women’s Public Toilet Room: |
||
1.17.1
|
No accessible mirror has been provided. |
6 months |
TR5 |
1.17.2
|
In the toilet compartment for persons with disabilities, the toilet seat cover dispenser is mounted with the controls 64 inches high. |
6 months |
CT4 |
1.17.3
|
In the toilet compartment for persons with disabilities, the toilet paper dispenser is mounted 12 inches from the front of the toilet to the centerline of the dispenser and the dispenser does not allow for continuous flow. |
6 months |
TR6 |
1.18
|
Toilet Room Near Meeting Rooms 389 to 391: The toilet paper dispenser is mounted more than 48” above the floor. |
6 months |
TR6 |
1.19
|
Second Floor South Men’s Public Toilet Room: |
||
1.19.1
|
No accessible mirror has been provided. |
6 months |
TR5 |
1.19.2
|
The urinal has a rim that is 22 inches high. |
12 months |
TR8 |
1.19.3
|
There is no side grab bar provided in the toilet compartment for persons with disabilities. |
6 months |
TR16 |
1.20
|
Courtroom 224 Probate Court and Jury Toilet Room: |
||
1.20.1
|
The signage provided does not have raised and Braille characters and is not mounted on the wall adjacent to the latch side of the door. |
6 months |
D15 |
1.20.2
|
The court room with a built-in sound system, has no portable assistive listening system available and there are no signs indicating the availability elsewhere of assistive listening systems. |
12 months |
AA4 |
1.20.3
|
The courtroom has raised jury boxes, judges’ benches, clerk stations, and witness stands with no means of vertical access for persons with disabilities and inadequate maneuvering clearances. |
18 months |
AR1 |
1.20.4
|
The courtroom does not have any or have inadequate wheelchair seating areas for spectators. |
12 months |
AA6 |
1.20.5
|
Although the facility contains a fire alarm system, there is no visible alarm provided in jury toilet room. |
12 months |
AL1 |
1.20.6
|
The lavatory water supply and drain pipes are not insulated or otherwise configured to |
9 months |
LS2 |
1.21
|
Courtroom 209 and Jury Toilet Room: |
||
1.21.1
|
The signage provided does not have raised and Braille characters and is not mounted on the wall adjacent to the latch side of the door. |
6 months |
D15 |
1.21.2
|
The court room with a built-in sound system, has no portable assistive listening system available and there are no signs indicating the availability elsewhere of assistive listening systems. |
12 months |
AA4 |
1.21.3
|
The courtroom has raised jury boxes, judges’ benches, clerk stations, and witness stands with no means of vertical access for persons with disabilities and inadequate maneuvering clearances. |
48 months |
AR1 |
1.21.4
|
The courtroom does not have any or have inadequate wheelchair seating areas for spectators. |
48 months |
AA6 |
1.21.5
|
Although the facility contains a fire alarm system, there is no visible alarm provided in jury toilet room. |
18 months |
AL1 |
1.21.6
|
The lavatory water supply and drain pipes are not insulated or otherwise configured to |
9 months |
LS2 |
1.22
|
Courtroom 283 Denver Probate Court: |
||
1.22.1
|
The signage provided does not have raised and Braille characters and is not mounted on the wall adjacent to the latch side of the door. |
6 months |
D15 |
1.23
|
Courtroom 275 and Jury Toilet Room: |
||
1.23.1
|
The court room with a built-in sound system, has no portable assistive listening system available and there are no signs indicating the availability elsewhere of assistive listening systems. |
12 months |
AA4 |
1.23.2
|
The courtroom has raised judges’ benches, clerk stations, and witness stands with no means of vertical access for persons with disabilities and inadequate maneuvering clearances. |
48 months |
AR1 |
1.23.3
|
The courtroom does not have any or have inadequate wheelchair seating areas for spectators. |
48 months |
AA6 |
1.23.4
|
The toilet room contains a number of inaccessible elements and is not accessible to people with disabilities. |
48 months |
TR1 |
1.24
|
Courtroom 269 and Jury Toilet Room: |
||
1.24.1
|
The court room with a built-in sound system, has no portable assistive listening system available and there are no signs indicating the availability elsewhere of assistive listening systems. |
12 months |
AA4 |
1.24.2
|
The courtroom has raised judges’ benches, clerk stations, and witness stands with no means of vertical access for persons with disabilities and inadequate maneuvering clearances. |
48 months |
AR1 |
1.24.3
|
The courtroom does not have any or have inadequate wheelchair seating areas for spectators. |
48 months |
AA6 |
1.24.4
|
The toilet room contains a number of inaccessible elements and is not accessible to people with disabilities. |
48 months |
TR1 |
1.25
|
Courtroom 259 and Jury Toilet Room: |
||
1.25.1
|
The court room with a built-in sound system, has no portable assistive listening system available and there are no signs indicating the availability elsewhere of assistive listening systems. |
12 months |
AA4 |
1.25.2
|
The courtroom has raised judges’ benches, clerk stations, and witness stands with no means of vertical access for persons with disabilities and inadequate maneuvering clearances. |
48 months |
AR1 |
1.25.3
|
The courtroom does not have any or have inadequate wheelchair seating areas for spectators. |
48 months |
AA6 |
1.25.4
|
The toilet room contains a number of inaccessible elements and is not accessible to people with disabilities. |
48 months |
TR1 |
1.26
|
Administrative Accounting Office: |
||
1.26.1
|
The counters protrude into the walkway and are not detectable to blind persons who use canes. |
6 months |
AR7 |
1.26.2
|
The counter is 42 inches high. |
9 months |
C1 |
1.27
|
Room 256 Denver District Court Main Clerk’s Office Civil and Domestic Matters: The counter is 42 inches high. |
6 months |
C1 |
1.28
|
Small Claims Courtroom and Clerks’ Office 159: |
||
1.28.1
|
The courtroom has raised judges’ benches, clerk stations, and witness stands with no means of vertical access for persons with disabilities and inadequate maneuvering clearances. |
48 months |
AR1 |
1.28.2
|
The courtroom does not have any or have inadequate wheelchair seating areas for spectators. |
36 months |
AA6 |
1.28.3
|
The court room with a built-in sound system, has no portable assistive listening system available and there are no signs indicating the availability elsewhere of assistive listening systems. |
12 months |
AA4 |
1.29
|
First Floor South Women’s Toilet Room: |
||
1.29.1
|
The automatic door actuator in mounted on the door. |
6 months |
D1 |
1.29.2
|
No accessible mirror has been provided. |
6 months |
TR5 |
1.29.3
|
In the toilet compartment for persons with disabilities, the toilet's flush control is on the closed side. |
18 months |
TR4 |
1.30
|
First Floor North Women’s Toilet Room: |
||
1.30.1
|
No accessible mirror has been provided. |
6 months |
TR5 |
1.30.2
|
In the toilet compartment for persons with disabilities, the toilet's flush control is on the closed side. |
18 months |
TR4 |
1.30.3
|
In the toilet compartment for persons with disabilities, the farthest toilet paper dispenser is mounted with its centerline 14 inches in front of the toilet. |
6 months |
TR6 |
1.31
|
First Floor North Men’s Toilet Room: |
||
1.31.1
|
No accessible mirror has been provided. |
6 months |
TR5 |
1.31.2
|
No lower urinal has been provided. |
12 months |
TR8 |
2
|
Garland Park, 6300 E. Mississippi Ave. |
||
2.1
|
Parking Lot South: |
||
2.1.1
|
The first designated accessible parking space has a cross slope of up to 4.6 % and there is no accessible signage provided for this space. |
18 months |
P6, P4 |
2.1.2
|
The sixth designated accessible parking space has a cross slope of up to 3.5% and the access aisle has a cross slope of up to 4.7% |
18 months |
P4 |
2.1.3
|
The parking lot has no van accessible parking space. |
12 months |
P5 |
2.2
|
Exterior Route From South Parking Lot: |
||
2.2.1
|
No accessible route is provided to the volleyball and basketball courts, baseball diamond and several picnic areas. |
48 months |
AR1 |
2.3
|
Exterior Route from North Parking Lot: The route from the north parking lot to the west side of the park has a slope of up to 24.2% at the curb ramp. |
48 months |
AR1 |
2.4
|
Drinking Fountains: The drinking fountains by the play area and by the NW toilet rooms protrude into the walkway and are not detectable to blind persons who use canes. |
9 months |
AR7 |
2.5
|
Women’s Toilet Room by Play Area: In the toilet compartment designated for persons with disabilities, the compartment door is not self-closing. |
9 months |
TR25 |
2.6
|
Men’s Toilet Room by Play Area: In the toilet compartment designated for persons with disabilities, the compartment door is not self-closing. |
9 months |
TR25 |
2.7
|
Playground: There is no accessible surface provided at the west playground equipment. |
48 months |
AR1 |
2.8
|
Directional Signage: No signs directing users to the areas equipped with accessible tables are |
6 months |
DW1, EB1 |
3
|
Minoru Yasui Plaza, 303 W. Colfax Ave. |
||
3.1
|
Ramps: The handrail extensions at the interior entrance ramp for customers are not returned to the floor or wall. The handrail on the wall side, near the bottom of the ramp, does not extend 12 inches parallel with the ground. |
12 months |
R2 |
3.2
|
Women’s Toilet Room – Main Lobby Entrance: The sanitary napkin dispenser controls require twisting of the wrist to operate. |
6 months |
CT2 |
4
|
Montbello Central Park, 14255 E. Andrews Drive |
||
4.1
|
Parking. No “van accessible” parking space is provided. |
12 months |
P5 |
4.2
|
Drinking Fountain at Baseball Field No. 4: |
||
4.2.1
|
The drinking protrudes into the walkway and is not detectable to blind persons who use canes. |
9 months |
AR7 |
4.3
|
Playground: |
||
4.3.1
|
In the playground, there are two elevated play structures, neither of which is served by an accessible route or surface. |
24 months |
PG1 |
4.3.2
|
No accessible route is provided to wheelchair location at the bench provided for caregivers near the play equipment. |
48 months |
AA6, AR1 |
5
|
Permit Center, 200 W. 14th Street |
||
5.1
|
Interior Route: Near the voter registration desks and the election division, the stations on the pedestrian lane dividers are not detectable to blind persons who use canes. |
18 months |
AR7 |
5.2
|
Elevators: In elevator car #3, the door to the emergency communication system requires tight grasping or pinching to operate. |
12 months |
E7 |
5.3
|
Toilet Rooms: |
||
5.4
|
Designated Accessible Toilet Rooms on Floors 1-3: The designated toilet rooms are not fully compliant. No directional signage is provided identifying the location of the full access toilet rooms in the basement. |
6 months |
TR10 |
5.5
|
1st through 3rd Floors Women’s and Men’s Toilet Rooms: Partially accessible. |
||
5.5.1
|
Insufficient maneuvering clearance is provided on the pull/latch side of the door. |
12 months |
D5 |
5.5.2
|
The paper towel dispenser protrudes into the walkway and is not detectable to blind persons who use canes. |
6 months |
AR7 |
5.5.3
|
No standard accessible toilet compartments are provided. |
18 months |
TR2 |
5.6
|
Basement Designated “Fully Accessible ” Women’s Toilet Room: |
||
5.6.1
|
The paper towel dispenser protrudes into the walkway and is not detectable to blind persons who use canes. |
6 months |
AR7 |
5.6.2
|
The sanitary napkin dispenser controls require twisting of the wrist to operate. |
6 months |
CT2 |
5.6.3
|
The coat hook is mounted 67 inches high. |
6 months |
TR3 |
5.6.4
|
In the toilet compartment designated for persons who use wheelchairs, the door is not self-closing and the door hardware requires tight grasping. |
12 months |
TR25, D2 |
5.7
|
Basement Designated “Fully Accessible” Men’s Toilet Room: |
||
5.7.1
|
The paper towel dispenser protrudes into the walkway and is not detectable to blind persons who use canes. |
6 months |
AR7 |
5.7.2
|
The toilet's flush control is on the closed side. |
18 months |
TR4 |
5.7.3
|
The toilet paper dispenser is mounted 40 inches from the front of the toilet. |
6 months |
TR6 |
5.7.4
|
In the toilet compartment designated for persons who use wheelchairs, the door is not self-closing and the door hardware requires tight grasping. |
12 months |
TR25, D2 |
6
|
Rocky Mountain Lake Park, 3301 W. 46th Ave. |
||
6.1
|
Parking: In the parking lot off 46th street along the middle of the park the marked access aisle is 38 inches wide. |
12 months |
P6 |
6.2
|
Middle Picnic Area: |
||
6.2.1
|
No accessible picnic table is provided. |
48 months |
DW1 |
6.2.2
|
No accessible route is provided to the barbeque grills. |
48 months |
AR1 |
6.3
|
Drinking Fountains Near West Parking Lot by Baseball Diamonds: |
||
6.3.1
|
The drinking fountain has a 29 inch knee clearance and protrudes into the walkway and is not detectable to blind persons who use canes. |
9 months |
AR7 |
6.4
|
Men’s Toilet Rooms Near Middle Parking Lot: |
||
6.4.1
|
The room signs are mounted at 47 inches high. |
6 months |
TR11 |
6.4.2
|
The toilet paper dispenser controls delivery and does not allow for a continuous flow. |
6 months |
TR6 |
6.5
|
Women’s Toilet Rooms Near Middle Parking Lot: |
||
6.5.1
|
The room signs are mounted at 47 inches high. |
6 months |
TR11 |
6.5.2
|
The toilet paper dispenser controls delivery and does not allow for a continuous flow. |
6 months |
TR6 |
6.6
|
Play Equipment: |
||
6.6.1
|
Play equipment does not include an entry point 11-24 inches above the ground. |
24 months |
PG1 |
6.7
|
West Parking Area: |
||
6.7.1
|
The parking space designated as “van accessible” has an access aisle that is 81 inches wide. |
12 months |
P6 |
6.7.2
|
The parking spaces designated for persons with disabilities have slopes and cross slopes exceeding 2.8%. |
12 months |
P4 |
6.8
|
East Parking Area: No designated “van accessible” parking space is provided. |
12 months |
P5 |
7
|
Sloan’s Lake Park, 1700 N. Sheridan Boulevard |
||
7.1
|
Parking Lot C by Boat House. One of the two marked spaces for people with disabilities does not have any access aisle. |
12 months |
P2 |
7.2
|
Women’s Toilet Rooms at the Marina (near Parking Lot C): |
||
7.2.1
|
The air dryer protrudes into the walkway and is not detectable to blind persons who use canes. |
6 months |
AR7 |
7.2.2
|
The toilet paper dispenser does not allow for a continuous paper flow. |
6 months |
TR6 |
7.3
|
Men’s Toilet Room at the Marina (near Parking Lot C): |
||
7.3.1
|
The air dryer protrudes into the walkway and is not detectable to blind persons who use canes. |
9 months |
AR7 |
7.3.2
|
The toilet paper dispenser does not allow for a continuous paper flow. |
6 months |
TR6 |
7.4
|
Parking Lot Near North Utica Street and West 26th Avenue (near parking lot D): The parking space designated for persons with disabilities near the tennis court has no access aisle, and no “van accessible” parking space is provided |
12 months |
P2, P5 |
7.5
|
Women’s Toilet Room Near North Playground (near Parking Lot D): |
||
7.6
|
Men’s Toilet Room Near North Playground (near Parking Lot D): The toilet paper dispenser does not allow for a continuous paper flow. |
6 months |
TR6 |
7.7
|
Women’s Toilet Room Near South Playground (near Parking Lot J): |
||
7.7.1
|
No accessible mirror is provided. |
6 months |
TR5 |
7.7.2
|
In the compartment for persons with disabilities, the toilet paper dispenser is mounted more than 9 inches from the front of the toilet and the dispenser does not allow for a continuous paper flow. |
6 months |
TR6 |
7.8
|
Men’s Toilet Room Near South Playground (near Parking Lot J): |
||
7.8.1
|
No accessible mirror is provided. |
6 months |
TR5 |
7.8.2
|
In the compartment for persons with disabilities, the toilet paper dispenser is mounted more than 9 inches from the front of the toilet and the dispenser does not allow for a continuous paper flow. |
6 months |
TR6 |
7.9
|
South Playground (near Parking Lot J): Although there are some ramps provided around the play equipment, there is an inadequate number and the ramps do not actually lead to any accessible components. |
12 months |
AR1 |
7.10
|
Boathouse Area (near Parking Lot C): |
||
7.10.1
|
No accessible route is provided to picnic tables or barbeque grills. |
48 months |
AR1 |
7.10.2
|
No accessible counters are provided inside the Ranger’s Office. |
9 months |
C1 |
7.11
|
Parking Lot H: In the parking lot on the south side of the park near North Perry Street, the space designated as “van accessible” has an access aisle that is 60 inches wide. |
12 months |
P6 |
|
Parking Lot I: In the parking lot on the south side of the park near North Stuart Street, the space designated as “van accessible” has an access aisle that is 60 inches wide. |
12 months |
P6 |
7.12
|
Parking J: In the parking lot near the south playground two designated accessible parking spaces lack signage, and no “van accessible” parking space is provided. |
12 months |
P3, P5 |
7.13
|
Parking Lot K: In the parking lot near the Gun Club no “van accessible” parking space is provided. Two of the three designated accessible parking spaces have a shared access which is 46 inches wide. |
12 months |
P1 |
8
|
Smiley Library, 4501 W. 46th Ave. |
||
8.1
|
Exterior Route: |
||
8.1.1
|
Along the route from the “Parks” parking lot to the library entrance, the walkway has a cross slope of up to 5.2%. |
36 months |
AR4 |
8.1.2
|
The ramp from the on-street parking to the library entrance has a slope of up to 9.7%. |
36 months |
R1 |
8.1.3
|
The ramp to the designated accessible side entrance has a slope of up to 9%. |
36 months |
R1 |
8.2
|
Exterior Signage: The building does not have directional signage posted at the inaccessible entrance. |
6 months |
D10 |
8.3
|
Unisex Toilet Room Behind Service Counter: |
||
8.3.1
|
Insufficient clear floor space is provided at the toilet due to storage of boxes. |
6 months |
TR24 |
8.3.2
|
The rear grab bar is 24 inches long and it is mounted with the far end less than 24 inches from the center of the toilet. |
6 months |
TR14 |
8.3.3
|
The coat hook is mounted at 68 inches high. |
6 months |
TR3 |
8.4
|
Elevator: |
||
8.4.1
|
The elevator door does not automatically reopen without contact if obstructed between 5 and 29 inches high. |
36 months |
E6 |
8.4.2
|
The door to the elevator’s emergency call controls requires right grasping to operate. |
12 months |
CT2 |
9
|
Woodbury Library, 3265 Federal Blvd. |
||
9.1
|
Parking: |
||
9.1.1
|
Sign is not 60 inches minimum above the finish floor or ground surface measured to the bottom of the sign. |
6 months |
P3 |
9.1.2
|
No van accessible parking space is provided. |
12 months |
P1 |
9.1.3
|
The designated accessible parking space does not have a level surface |
36 months |
P1 |
9.1.4
|
No access aisle is provided at the designated accessible parking space. |
12 months |
P1 |
9.2
|
Accessible Route: |
||
9.2.1
|
The curb ramp from the designated accessible parking space to the sidewalk has a slope of up to 9%. |
36 months |
R4 |
9.2.2
|
The ramp to the entrance has a running slope of up to 12.1%. |
36 months |
R4 |
9.2.3
|
The top leg of the ramp to the entrance has handrails only on one side. |
36 months |
R2 |
9.2.4
|
The building does not have directional signage posted at the inaccessible entrance. |
6 months |
D10 |
9.3
|
Unisex Toilet Room Lower Level Children’s Room (this room is labeled “Staff Restroom,” although it is made available to customers through a key system): The toilet's flush control is on the closed side. |
18 months |
TR4 |
10
|
Hadley Library, 1890 S. Grove Street |
||
10.1
|
Parking: |
||
10.1.1
|
No “van accessible” parking space is provided. |
12 months |
P5 |
10.1.2
|
At the built-up curb ramp serving the parking lot, there is a cross-slope of 2.8 percent. |
18 months |
AR1 |
10.2
|
Women’s Toilet Room Near Entrance: |
||
10.2.1
|
The flush control is on the “closed” side. |
18 months |
TR4 |
10.2.2
|
The coat hook is 67 inches high. |
6 months |
CT4 |
10.3
|
Men’s Toilet Room Near Entrance: |
||
10.3.1
|
No accessible mirror is provided. |
18 months |
TR5 |
10.3.2
|
The coat hook is 67 inches high. |
6 months |
CT4 |
10.3.3
|
The far end of the side grab bar is 52 inches from the rear wall. |
18 months |
TR17 |
10.4
|
Drinking Fountain: The higher drinking fountain near the toilet rooms protrudes into the walkway and is not detectable to blind persons who use canes. |
18 months |
AR7 |