Item # |
Location Description |
Element |
Attribute |
Actual On Site Value |
Remedial Code |
Violation |
Completion Time |
16.2.1.1 |
Level 1 Break Room - Infants New Beginning |
Lavatory Sink |
Dimension, height of knee clearance |
0 |
LS3 |
Insufficient clearance |
36 months |
16.2.1.2 |
Level 1 Break Room - Infants New Beginning |
Lavatory Sink |
Dimension, height |
35.5 |
LS3 |
Insufficient height - Too high |
36 months |
16.2.2.1 |
Level 1 Hallway - Care Center |
Door/Gate |
Closing speed |
3 |
D1 |
Too fast |
24 months |
16.2.2.2 |
Level 1 Hallway - Care Center |
Door/Gate |
Opening force |
9 |
D3 |
Excessive force - Too high |
24 months |
16.2.3.1 |
Level 1 Kitchen - Care Center |
Lavatory Sink |
Dimension, height of knee clearance |
0 |
LS3 |
Insufficient clearance |
36 months |
16.2.3.2 |
Level 1 Kitchen - Care Center |
Lavatory Sink |
Dimension, height |
36 |
LS3 |
Insufficient height - Too high |
36 months |
16.2.3.3 |
Level 1 Kitchen - Care Center |
Range/Oven/Cooktop |
Hardware operable |
No |
CT2 |
Requires tight grasping, pinching, or twisting of the wrist |
12 months |
16.2.3.4 |
Level 1 Kitchen - Care Center |
Range/Oven/Cooktop |
Location of controls |
Rear |
K1 |
Incorrect control configuration - Not located on the front panel |
12 months |
16.2.4.1 |
Level 1 Kitchen - Care Center 2 |
Lavatory Sink |
Dimension, height of knee clearance |
0 |
LS3 |
Insufficient clearance |
36 months |
16.2.4.2 |
Level 1 Kitchen - Care Center 2 |
Lavatory Sink |
Dimension, height |
35.75 |
LS3 |
Insufficient height - Too high |
36 months |
16.2.4.3 |
Level 1 Kitchen - Care Center 2 |
Range/Oven/Cooktop |
Hardware operable |
No |
CT2 |
Requires tight grasping, pinching, or twisting of the wrist |
12 months |
16.2.4.4 |
Level 1 Kitchen - Care Center 2 |
Range/Oven/Cooktop |
Location of controls |
Rear |
K1 |
Incorrect control configuration - Not located on the front panel |
12 months |
16.2.5.1 |
Level 1 Lobby |
Other Element - Public Portal computer access station |
Accessible computer provided |
No |
C2 |
No accessible computer provided - standing use only |
36 months |
16.2.5.2 |
Level 1 Lobby |
Protrusion - Child Services Drop box |
Dimension, depth |
7 |
AR7 |
Protruding object(s) present |
36 months |
16.2.5.3 |
Level 1 Lobby |
Table - Public Portal computer access station |
Dimension, height of knee clearance |
19 |
DW1 |
Insufficient height - Insufficient clearance |
24 months |
16.2.6.1 |
Level 1 Lobby - Care Center |
Door/Gate |
Opening force |
8 |
D3 |
Excessive force - Too high |
24 months |
16.2.6.2 |
Level 1 Lobby - Care Center |
Protrusion - two wall mount TVs |
Dimension, depth |
22 |
AR7 |
Protruding object(s) present |
36 months |
16.2.6.3 |
Level 1 Lobby - Care Center |
Alarm System |
Dimension, height of wall mount |
78.5 |
AL1 |
Insufficient height - Too low |
24 months |
16.2.6.4 |
Level 1 Lobby - Care Center |
Operable Part - Comment Box |
Dimension, height |
58.5 |
CT4 |
Outside of reach range - Too high |
24 months |
16.2.6.5 |
Level 1 Lobby - Care Center |
Operable Part - hand sanitation at counter |
Dimension, height |
54 |
CT4 |
Outside of reach range - Too high |
24 months |
16.2.7.1 |
Level 1 Lobby - Child Support |
Counter |
Dimension, height |
42.25 |
C1 |
Insufficient height - Too high |
12 months |
16.2.7.2 |
Level 1 Lobby - Child Support |
Signage, Designation - Typical to all small meeting rooms |
Dimension, height to lowest tactile text |
63.5 |
D15 |
Insufficient height - Sign height is not compliant |
12 months |
16.2.7.3 |
Level 1 Lobby - Child Support |
Protrusion - Take a number box wall mounted |
Dimension, depth |
11 |
AR7 |
Protruding object(s) present |
36 months |
16.2.7.4 |
Level 1 Lobby - Child Support |
Protrusion - Wall mount flat screen Television |
Dimension, depth |
24 |
AR7 |
Protruding object(s) present |
36 months |
16.2.7.5 |
Level 1 Lobby - Child Support |
Protrusion - Wall mount flat screen Television above reception counter |
Dimension, depth |
17 |
AR7 |
Protruding object(s) present |
36 months |
16.2.8.1 |
Level 1 Lobby - Denver Workforce Services |
Counter - Main Hall Area |
Dimension, height |
42 |
C1 |
Insufficient height - Too high |
12 months |
16.2.8.2 |
Level 1 Lobby - Denver Workforce Services |
Counter - Westside Room |
Dimension, height |
42.5 |
C1 |
Insufficient height - Too high |
12 months |
16.2.9 |
Level 1 Lobby - Good Beginnings |
Door/Gate |
Opening force |
9 |
D3 |
Excessive force - Too high |
24 months |
16.2.10.1 |
Level 1 Lobby - Self Service Center Rm. 1026 |
Door/Gate |
Dimension, height of smooth surface - Door Stop |
0 |
D1 |
Insufficient smooth surface |
24 months |
16.2.10.2 |
Level 1 Lobby - Self Service Center Rm. 1026 |
Door/Gate |
Opening force |
8 |
D3 |
Excessive force - Too high |
24 months |
16.2.10.3 |
Level 1 Lobby - Self Service Center Rm. 1026 |
Signage, Designation |
Dimension, height to lowest tactile text |
60.25 |
D15 |
Insufficient height - Sign height is not compliant |
12 months |
16.2.10.4 |
Level 1 Lobby - Self Service Center Rm. 1026 |
Protrusion - Recertification Box |
Dimension, depth |
7.25 |
AR7 |
Protruding object(s) present |
36 months |
16.2.10.5 |
Level 1 Lobby - Self Service Center Rm. 1026 |
Protrusion - Work Force Box |
Dimension, depth |
7.75 |
AR7 |
Protruding object(s) present |
36 months |
16.2.10.6 |
Level 1 Lobby - Self Service Center Rm. 1026 |
Operable Part - Recertification |
Dimension, height - slot |
54 |
CT4 |
Outside of reach range -Too high |
24 months |
16.2.10.7 |
Level 1 Lobby - Self Service Center Rm. 1026 |
Operable Part - CCAP, Report forms, LEAP Mail |
Dimension, height |
54 |
CT4 |
Outside of reach range -Too high |
24 months |
16.2.11.1 |
Level 1 Restroom Mens - Boys Single User |
Door/Gate |
Closing speed |
4 |
D1 |
Too fast |
24 months |
16.2.11.2 |
Level 1 Restroom Mens - Boys Single User |
Door/Gate |
Dimension, height of smooth surface - door stop |
0 |
D1 |
Insufficient smooth surface |
24 months |
16.2.11.3 |
Level 1 Restroom Mens - Boys Single User |
Door/Gate |
Opening force |
10 |
D3 |
Excessive force - Too high |
24 months |
16.2.11.4 |
Level 1 Restroom Mens - Boys Single User |
Alarm System |
Dimension, height of wall mount |
78.5 |
AL1 |
Insufficient height - Too low |
24 months |
16.2.11.5 |
Level 1 Restroom Mens - Boys Single User |
Grab Bar Rear |
Dimension, to object above grab bar - water supply |
4.5 |
TR15 |
Object too close to grab bar |
12 months |
16.2.11.6 |
Level 1 Restroom Mens - Boys Single User |
Water Closet |
Dimension, height of seat |
15 |
TR9 |
Insufficient height - Too low |
36 months |
16.2.11.7 |
Level 1 Restroom Mens - Boys Single User |
Grab Bar Rear |
Dimension, length |
30 |
TR14 |
Insufficient length - Too short |
12 months |
16.2.11.8 |
Level 1 Restroom Mens - Boys Single User |
Dispenser, Toilet Paper |
Dimension, from water closet seat |
2 |
TR6 |
Insufficient distance - Wrong location |
12 months |
16.2.11.9 |
Level 1 Restroom Mens - Boys Single User |
Lavatory Sink |
Dimension, height of knee clearance |
17 |
LS3 |
Insufficient clearance |
36 months |
16.2.12.1 |
Level 1 Restroom Mens - Care Center Child |
Alarm System |
Dimension, height of wall mount |
78.5 |
AL1 |
Insufficient height - Too low |
24 months |
16.2.12.2 |
Level 1 Restroom Mens - Care Center Child |
Water Closet |
Dimension, height of seat |
15.5 |
TR9 |
Insufficient height - Too low |
36 months |
16.2.12.3 |
Level 1 Restroom Mens - Care Center Child |
Grab Bar Rear |
Dimension, height to top |
31 |
TR19 |
Insufficient height - Too low |
12 months |
16.2.12.4 |
Level 1 Restroom Mens - Care Center Child |
Grab Bar Rear |
Dimension, length |
30 |
TR14 |
Insufficient length - Too short |
12 months |
16.2.12.5 |
Level 1 Restroom Mens - Care Center Child |
Grab Bar Side |
Dimension, height to top |
31 |
TR19 |
Insufficient height - Too low |
12 months |
16.2.12.6 |
Level 1 Restroom Mens - Care Center Child |
Grab Bar Side |
Dimension, to object above grab bar - Toilet Paper |
3 |
TR15 |
Object too close to grab bar |
12 months |
16.2.12.7 |
Level 1 Restroom Mens - Care Center Child |
Dispenser, Toilet Paper |
Dimension, from water closet seat |
0 |
TR6 |
Insufficient distance - Wrong location |
12 months |
16.2.12.8 |
Level 1 Restroom Mens - Care Center Child |
Lavatory Sink |
Dimension, height of knee clearance |
17 |
LS3 |
Insufficient clearance |
36 months |
16.2.13.1 |
Level 1 Restroom Mens - Near Main Stairs |
Alarm System |
Dimension, height of wall mount |
78.5 |
AL1 |
Insufficient height - Too low |
24 months |
16.2.13.2 |
Level 1 Restroom Mens - Near Main Stairs |
Grab Bar Side |
Dimension, to object above grab bar - YP |
4 |
TR15 |
Object too close to grab bar |
12 months |
16.2.13.3 |
Level 1 Restroom Mens - Near Main Stairs |
Fixture Count |
Number, ambulatory compartments |
0 |
TR22 |
No ambulatory compartment provided |
36 months |
16.2.13.4 |
Level 1 Restroom Mens - Near Main Stairs |
Dispenser, Toilet Paper |
Dimension, from water closet seat |
4 |
TR6 |
Insufficient distance - Wrong location |
12 months |
16.2.13.5 |
Level 1 Restroom Mens - Near Main Stairs |
Protrusion - Paper Towel Dispenser |
Dimension, depth |
9 |
AR7 |
Protruding object(s) present |
36 months |
16.2.13.6 |
Level 1 Restroom Mens - Near Main Stairs |
Changing Station |
Clearance, perpendicular - 33.5 closed |
14 |
AR10 |
Insufficient clear floor space |
24 months |
16.2.14.1 |
Level 1 Restroom Unisex - Care Center |
Alarm System |
Dimension, height of wall mount |
78 |
AL1 |
Insufficient height - Too low |
24 months |
16.2.14.2 |
Level 1 Restroom Unisex - Care Center |
Water Closet |
Dimension, sidewall to centerline |
20.5 |
TR7 |
Insufficient distance - Too far |
36 months |
16.2.14.3 |
Level 1 Restroom Unisex - Care Center |
Grab Bar Rear |
24" from centerline on open side |
NO |
TR14 |
Insufficient distance |
12 months |
16.2.15.1 |
Level 1 Restroom Unisex - Care Center Near Kitchen 2 |
Changing Station |
Dimension, height of maximum reach |
50 |
TR1 |
Insufficient height - Too high |
24 months |
16.2.15.2 |
Level 1 Restroom Unisex - Care Center Near Kitchen 2 |
Changing Station |
Dimension, height to table top lip/edge |
37 |
DW1 |
Insufficient height - Too high |
24 months |
16.2.15.3 |
Level 1 Restroom Unisex - Care Center Near Kitchen 2 |
Alarm System |
Dimension, height of wall mount |
78.5 |
AL1 |
Insufficient height - Too high |
24 months |
16.2.15.4 |
Level 1 Restroom Unisex - Care Center Near Kitchen 2 |
Grab Bar Side |
Dimension, to object above grab bar - TP |
7 |
TR15 |
Object too close to grab bar |
12 months |
16.2.15.5 |
Level 1 Restroom Unisex - Care Center Near Kitchen 2 |
Dispenser, Toilet Paper |
Dimension, from water closet seat |
2 |
TR6 |
Insufficient distance - Wrong location |
12 months |
16.2.15.6 |
Level 1 Restroom Unisex - Care Center Near Kitchen 2 |
Dispenser, Seat Cover |
Dimension, height of operable part |
60 |
TR1 |
Insufficient height - Too high |
12 months |
16.2.16.1 |
Level 1 Restroom Unisex - Toddlers |
Signage, Designation |
ISA symbol provided on sign |
No |
TR11 |
No ISA symbol provided |
12 months |
16.2.16.2 |
Level 1 Restroom Unisex - Toddlers |
Grab Bar Rear |
Dimension, to object above grab bar - Water supply |
0.75 |
TR15 |
Object too close to grab bar |
12 months |
16.2.16.3 |
Level 1 Restroom Unisex - Toddlers |
Grab Bar Rear |
Dimension, length |
24 |
TR14 |
Insufficient length - Too short |
12 months |
16.2.16.4 |
Level 1 Restroom Unisex - Toddlers |
Grab Bar Side |
Dimension, to object above grab bar - Toilet Paper |
6 |
TR15 |
Object too close to grab bar |
12 months |
16.2.16.5 |
Level 1 Restroom Unisex - Toddlers |
Grab Bar Side |
Dimension, length |
24 |
TR17 |
Insufficient length - Too short |
12 months |
16.2.16.6 |
Level 1 Restroom Unisex - Toddlers |
Water Closet - with grab bars |
Clearance, parallel |
57 |
TR2 |
Insufficient clearance |
36 months |
16.2.16.7 |
Level 1 Restroom Unisex - Toddlers |
Water Closet - with grab bars |
Dimension, sidewall to centerline |
15.25 |
TR7 |
Insufficient distance - Too far |
36 months |
16.2.16.8 |
Level 1 Restroom Unisex - Toddlers |
Water Closet - with grab bars |
Dimension, height of seat |
11.25 |
TR9 |
Insufficient height - Too low |
36 months |
16.2.16.9 |
Level 1 Restroom Unisex - Toddlers |
Lavatory Sink |
Dimension, height of knee clearance |
17 |
LS3 |
Insufficient clearance |
36 months |
16.2.17.1 |
Level 1 Restroom Womens - Care Center |
Lavatory Sink - Child |
Pipes protected |
No |
LS2 |
Not protected against contact - Not wrapped |
36 months |
16.2.17.2 |
Level 1 Restroom Womens - Care Center |
Alarm System - Child |
Dimension, height of wall mount |
78 |
AL1 |
Insufficient height - Too low |
24 months |
16.2.17.3 |
Level 1 Restroom Womens - Care Center |
Water Closet - Child |
Dimension, height of seat |
16 |
TR9 |
Insufficient height - Too low |
36 months |
16.2.17.4 |
Level 1 Restroom Womens - Care Center |
Grab Bar Rear - Child |
Dimension, height to top |
29.5 |
TR19 |
Insufficient height - Too low |
12 months |
16.2.17.5 |
Level 1 Restroom Womens - Care Center |
Grab Bar Rear - Child |
Dimension, length |
30 |
TR14 |
Insufficient length - Too short |
12 months |
16.2.17.6 |
Level 1 Restroom Womens - Care Center |
Grab Bar Rear - Child |
24" from centerline on open side |
NO |
TR14 |
Insufficient distance |
12 months |
16.2.17.7 |
Level 1 Restroom Womens - Care Center |
Grab Bar Side - Child |
Dimension, height to top |
29.5 |
TR19 |
Insufficient height - Too low |
12 months |
16.2.17.8 |
Level 1 Restroom Womens - Care Center |
Lavatory Sink - Child |
Dimension, height of knee clearance |
17 |
LS3 |
Insufficient clearance |
36 months |
16.2.18.1 |
Level 1 Restroom Womens - Care Center |
Door/Gate |
Closing speed |
4 |
D1 |
Too fast |
24 months |
16.2.18.2 |
Level 1 Restroom Womens - Care Center |
Door/Gate |
Dimension, height of smooth surface - door stop |
0 |
D1 |
Insufficient smooth surface |
24 months |
16.2.18.3 |
Level 1 Restroom Womens - Care Center |
Alarm System |
Dimension, height of wall mount |
78.5 |
AL1 |
Insufficient height - Too low |
24 months |
16.2.18.4 |
Level 1 Restroom Womens - Care Center |
Grab Bar Rear |
Dimension, to object above grab bar - supply line |
4 |
TR15 |
Object too close to grab bar |
12 months |
16.2.18.5 |
Level 1 Restroom Womens - Care Center |
Grab Bar Rear |
24" from centerline on open side |
No |
TR14 |
Insufficient distance |
12 months |
16.2.18.6 |
Level 1 Restroom Womens - Care Center |
Water Closet |
Dimension, height of seat |
15 |
TR9 |
Insufficient height - Too low |
36 months |
16.2.18.7 |
Level 1 Restroom Womens - Care Center |
Lavatory Sink |
Dimension, height of knee clearance |
17 |
LS3 |
Insufficient clearance |
36 months |
16.2.19.1 |
Level 1 Restroom Womens - Near Main Stairs |
Lavatory Sink |
Pipes protected |
No |
LS2 |
Not protected against contact - Not wrapped |
36 months |
16.2.19.2 |
Level 1 Restroom Womens - Near Main Stairs |
Alarm System |
Dimension, height of wall mount |
78.5 |
AL1 |
Insufficient height - Too low |
24 months |
16.2.19.3 |
Level 1 Restroom Womens - Near Main Stairs |
Grab Bar Side |
Dimension, to object above grab bar |
3 |
TR15 |
Object too close to grab bar |
12 months |
16.2.19.4 |
Level 1 Restroom Womens - Near Main Stairs |
Fixture Count |
Number, ambulatory compartments |
0 |
TR22 |
No ambulatory compartment provided |
36 months |
16.2.19.5 |
Level 1 Restroom Womens - Near Main Stairs |
Toilet Compartment |
Handle on both sides |
No |
TR25 |
Pull is not provided on both sides |
36 months |
16.2.19.6 |
Level 1 Restroom Womens - Near Main Stairs |
Grab Bar Rear |
12" from centerline on narrow side |
No |
TR14 |
Insufficient distance |
12 months |
16.2.19.7 |
Level 1 Restroom Womens - Near Main Stairs |
Operable Part - Medical waste |
Dimension, height |
58 |
CT4 |
Outside of reach range - Too high |
24 months |
Item # |
Location Description |
Element |
Attribute |
Actual On Site Value |
Remedial Code |
Violation |
Completion Time |
16.5.1.1 |
Parking Facility Parking Garage |
Access Aisle - S3-S4 |
Connected to accessible route |
No |
P9 |
Not connected to an accessible route |
24 months |
16.5.1.2 |
Parking Facility Parking Garage |
Access Aisle - S5-S6 |
Connected to accessible route |
No |
P9 |
Not connected to an accessible route |
24 months |
16.5.1.3 |
Parking Facility Parking Garage |
Parking Space - S1 |
Dimension, height of sign |
43 |
P3 |
Insufficient sign height - Too low |
24 months |
16.5.1.4 |
Parking Facility Parking Garage |
Parking Space - S2 |
Access aisle provided |
No |
P2 |
No access aisle provided |
24 months |
16.5.1.5 |
Parking Facility Parking Garage |
Parking Space - S2 |
Dimension, height of sign |
52.75 |
P3 |
Insufficient sign height - Too low |
24 months |
16.5.1.6 |
Parking Facility Parking Garage |
Parking Space - S3 |
Dimension, height of sign |
53 |
P3 |
Insufficient sign height - Too low |
24 months |
16.5.1.7 |
Parking Facility Parking Garage |
Parking Space - S4 |
Dimension, height of sign |
52.5 |
P3 |
Insufficient sign height - Too low |
24 months |
16.5.1.8 |
Parking Facility Parking Garage |
Parking Space - S5 |
Dimension, height of sign |
2.5 |
P3 |
Insufficient sign height - Too low |
24 months |
16.5.1.9 |
Parking Facility Parking Garage |
Parking Space - S6 |
Dimension, height of sign |
53 |
P3 |
Insufficient sign height - Too low |
24 months |
16.5.1.10 |
Parking Facility Parking Garage |
Parking Space - S7 |
Dimension, height of sign |
54 |
P3 |
Insufficient sign height - Too low |
24 months |
16.5.1.11 |
Parking Facility Parking Garage |
Parking Space - S8 |
Access aisle provided |
No |
P2 |
No access aisle provided |
24 months |
16.5.1.12 |
Parking Facility Parking Garage |
Parking Space - S8 |
Dimension, height of sign |
55 |
P3 |
Insufficient sign height |
24 months |
16.5.1.13 |
Parking Facility Parking Garage |
Other Element - Typical Emergency Call Stations |
Slope, maximum |
9.6 |
AR10 |
Excessive slope |
36 months |
16.5.1.14 |
Parking Facility Parking Garage |
Operable Part - Typical Emergency Call Stations |
Dimension, height of operable part - to button |
50 |
CT4 |
Outside of reach range - Too high |
24 months |
16.5.2.1 |
Parking Facility Surface Lot |
Access Aisle - R2 1-2 |
Connected to accessible route |
No |
P9 |
Not connected to an accessible route |
24 months |
16.5.2.2 |
Parking Facility Surface Lot |
Access Aisle - R2 3-4 |
Connected to accessible route |
No |
P9 |
Not connected to an accessible route |
24 months |
16.5.2.3 |
Parking Facility Surface Lot |
Access Aisle - R2 5-6 |
Connected to accessible route |
No |
P9 |
Not connected to an accessible route |
24 months |
16.5.2.4 |
Parking Facility Surface Lot |
Access Aisle - R2 7-8 |
Connected to accessible route |
No |
P9 |
Not connected to an accessible route |
24 months |
16.5.2.5 |
Parking Facility Surface Lot |
Access Aisle - R3 1-2 |
Connected to accessible route |
No |
P9 |
Not connected to an accessible route |
24 months |
16.5.2.6 |
Parking Facility Surface Lot |
Access Aisle - R3 3-4 |
Connected to accessible route |
No |
P9 |
Not connected to an accessible route |
24 months |
16.5.2.7 |
Parking Facility Surface Lot |
Access Aisle - R3 5-6 |
Connected to accessible route |
No |
P9 |
Not connected to an accessible route |
24 months |
16.5.2.8 |
Parking Facility Surface Lot |
Access Aisle - R3 7-8 |
Slope, cross |
2.4 |
P4 |
Excessive slope |
24 months |
16.5.2.9 |
Parking Facility Surface Lot |
Access Aisle - R3 7-8 |
Connected to accessible route |
No |
P9 |
Not connected to an accessible route |
24 months |
16.5.2.10 |
Parking Facility Surface Lot |
Parking Space - E1 |
Access aisle provided |
No |
P2 |
No access aisle provided |
24 months |
16.5.2.11 |
Parking Facility Surface Lot |
Parking Space - E1 |
Dim, height of sign |
50 |
P3 |
Insufficient sign height - Too low |
24 months |
16.5.2.12 |
Parking Facility Surface Lot |
Parking Space - E2 |
Access aisle provided |
No |
P2 |
No access aisle provided |
24 months |
16.5.2.13 |
Parking Facility Surface Lot |
Parking Space - E2 |
Dim, height of sign |
50 |
P3 |
Insufficient sign height - Too low |
24 months |
16.5.2.14 |
Parking Facility Surface Lot |
Parking Space - E3 |
Access aisle provided |
No |
P2 |
No access aisle provided |
24 months |
16.5.2.15 |
Parking Facility Surface Lot |
Parking Space - E3 |
Dim, height of sign |
48 |
P3 |
Insufficient sign height - Too low |
24 months |
16.5.2.16 |
Parking Facility Surface Lot |
Parking Space - E4 |
Access aisle provided |
No |
P2 |
No access aisle provided |
24 months |
16.5.2.17 |
Parking Facility Surface Lot |
Parking Space - E4 |
Dim, height of sign |
50 |
P3 |
Insufficient sign height - Too low |
24 months |
16.5.2.18 |
Parking Facility Surface Lot |
Parking Space - E5 |
Access aisle provided |
No |
P2 |
No access aisle provided |
24 months |
16.5.2.19 |
Parking Facility Surface Lot |
Parking Space - E5 |
Dim, height of sign |
50 |
P3 |
Insufficient sign height - Too low |
24 months |
16.5.2.20 |
Parking Facility Surface Lot |
Parking Space - E5 |
Slope, running |
4.9 |
P4 |
Excessive slope |
24 months |
16.5.2.21 |
Parking Facility Surface Lot |
Parking Space - E6 |
Access aisle provided |
No |
P2 |
No access aisle provided |
24 months |
16.5.2.22 |
Parking Facility Surface Lot |
Parking Space - E6 |
Dim, height of sign |
50 |
P3 |
Insufficient sign height - Too low |
24 months |
16.5.2.23 |
Parking Facility Surface Lot |
Parking Space - R1 S6 |
Dim, height of sign |
56 |
P3 |
Insufficient sign height - Too low |
24 months |
16.5.2.24 |
Parking Facility Surface Lot |
Parking Space - R1 - S2 |
Dim, height of sign |
58 |
P3 |
Insufficient sign height - Too low |
24 months |
16.5.2.25 |
Parking Facility Surface Lot |
Parking Space - R1 S3 |
Dim, height of sign |
58 |
P3 |
Insufficient sign height - Too low |
24 months |
16.5.2.26 |
Parking Facility Surface Lot |
Parking Space - R1 S4 |
Dim, height of sign |
56 |
P3 |
Insufficient sign height - Too low |
24 months |
16.5.2.27 |
Parking Facility Surface Lot |
Parking Space - R1 S5 |
Dim, height of sign |
57 |
P3 |
Insufficient sign height - Too low |
24 months |
16.5.2.28 |
Parking Facility Surface Lot |
Parking Space - R1 S7 |
Dim, height of sign |
55 |
P3 |
Insufficient sign height - Too low |
24 months |
16.5.2.29 |
Parking Facility Surface Lot |
Parking Space - R1 S8 |
Dim, height of sign |
55 |
P3 |
Insufficient sign height - Too low |
24 months |
16.5.2.30 |
Parking Facility Surface Lot |
Parking Space - R2 1 |
Sign provided |
No |
P3 |
Sign not provided |
24 months |
16.5.2.31 |
Parking Facility Surface Lot |
Parking Space - R2 S2 |
Sign provided |
No |
P3 |
Sign not provided |
24 months |
16.5.3.1 |
Parking Facility Walkway |
Door/Gate - ext. door from garage |
Slope, running - Exterior |
4.8 |
D7 |
Excessive slope |
24 months |
16.5.3.2 |
Parking Facility Walkway |
Ramp - Median 2 |
Slope, running |
9.4 |
R5 |
Excessive slope |
24 months |
16.5.3.3 |
Parking Facility Walkway |
Ramp - Median 2 |
Landings provided at both top and bottom |
No |
R5 |
Landings are not provided at both top and bottom |
24 months |
16.5.3.4 |
Parking Facility Walkway |
Ramp - Median 2 |
Handrails on both sides |
No |
R2 |
Handrails are not on both sides |
24 months |
16.5.3.5 |
Parking Facility Walkway |
Ramp - Median to sidewalk at Level 1 entry |
Slope, cross |
3.4 |
R1 |
Excessive slope |
24 months |
16.5.3.6 |
Parking Facility Walkway |
Ramp - Median to sidewalk at Level 1 entry |
Landings provided at both top and bottom |
No |
R5 |
Landings are not provided at both top and bottom |
24 months |
16.5.3.7 |
Parking Facility Walkway |
Ramp - Median to sidewalk at Level 1 entry |
Handrails on both sides |
No |
R2 |
Handrails are not on both sides |
24 months |
16.5.3.8 |
Parking Facility Walkway |
Walking Surface - Vestibule to Crosswalk 1 |
Slope, cross |
3.2 |
AR1 |
Excessive slope |
24 months |
16.5.3.9 |
Parking Facility Walkway |
Walking Surface - Vestibule to Crosswalk 1 |
Slope, running |
7.5 |
AR1 |
Excessive slope |
24 months |
16.5.3.10 |
Parking Facility Walkway |
Walking Surface - Access aisle R1 4-5 |
Slope, running |
6.8 |
AR1 |
Excessive slope |
24 months |
16.5.3.11 |
Parking Facility Walkway |
Walking Surface - Crosswalk 2 |
Slope, cross |
4.6 |
AR1 |
Excessive slope |
24 months |
16.5.3.12 |
Parking Facility Walkway |
Walking Surface - Crosswalk 3 |
Slope, cross |
3.6 |
AR1 |
Excessive slope |
24 months |
16.5.3.13 |
Parking Facility Walkway |
Walking Surface - Median 1 |
Slope, running |
7.7 |
AR1 |
Excessive slope |
24 months |
16.5.3.14 |
Parking Facility Walkway |
Walking Surface |
Slope, cross - Cross slope issues approaching entry. Range from 3.4% - 6.4% |
6.4 |
AR1 |
Excessive slope |
24 months |
Item # |
Location Description |
Element |
Attribute |
Actual On Site Value |
Remedial Code |
Violation |
Completion Time |
17.2.1 |
Interior Elevator - P1 |
Car Controls |
Floor buttons arranged left to right or bottom to top |
No |
E4 |
Incorrect configuration - Not arranged properly |
36 months |
17.2.2.1 |
Interior Other Room - Elevator Bay at P1.F.EL |
Alarm System |
Dimension, height of wall mount |
78.5 |
AL1 |
Insufficient height - Too low |
36 months |
17.2.2.2 |
Interior Other Room - Elevator Bay at P1.F.EL |
Protrusion - Fire extinguisher |
Dimension, depth |
7.5 |
AR7 |
Protruding object(s) present |
36 months |
17.2.2.3 |
Interior Other Room - Elevator Bay at P1.F.EL |
Protrusion - Visual alarm |
Dimension, depth |
5.75 |
AR7 |
Protruding object(s) present |
36 months |
17.2.2.4 |
Interior Other Room - Elevator Bay at P1.F.EL |
Protrusion - emergency phone |
Dimension, depth |
6.75 |
AR7 |
Protruding object(s) present |
36 months |
17.2.2.5 |
Interior Other Room - Elevator Bay at P1.F.EL |
Signage, Designation |
Dimension, height to lowest tactile text |
61.25 |
D15 |
Insufficient height - Too high |
36 months |
17.2.2.6 |
Interior Other Room - Elevator Bay at P1.F.EL |
Signage, Designation |
Signage location |
Hinge |
D15 |
Incorrect positioning - Wrong location |
36 months |
17.2.3.1 |
Interior Other Room - Elevator Bay at P2.C.EL |
Door/Gate |
Closing speed |
3.5 |
D1 |
Too fast |
36 months |
17.2.3.2 |
Interior Other Room - Elevator Bay at P2.C.EL |
Door/Gate |
Opening force |
7 |
D3 |
Excessive force - Too high |
36 months |
17.2.3.3 |
Interior Other Room - Elevator Bay at P2.C.EL |
Protrusion - Outside room |
Dimension, depth |
7.5 |
AR7 |
Protruding object(s) present |
36 months |
17.2.3.4 |
Interior Other Room - Elevator Bay at P2.C.EL |
Signage, Designation |
Signage location |
Hinge |
D15 |
Incorrect positioning - Wrong location |
36 months |
17.2.4.1 |
Interior Other Room - Elevator bay at P2.F.EL |
Alarm System |
Dimension, height of wall mount |
78.5 |
AL1 |
Insufficient height - too low |
36 months |
17.2.4.2 |
Interior Other Room - Elevator bay at P2.F.EL |
Door/Gate to elevators at P2.F.EL |
Opening force |
7 |
D3 |
Excessive force - Too high |
36 months |
17.2.4.3 |
Interior Other Room - Elevator bay at P2.F.EL |
Protrusion - emergency phone |
Dimension, depth |
7 |
AR7 |
Protruding object(s) present |
36 months |
17.2.4.4 |
Interior Other Room - Elevator bay at P2.F.EL |
Protrusion - fire extinguisher |
Dimension, depth |
7.5 |
AR7 |
Protruding object(s) present |
36 months |
17.2.4.5 |
Interior Other Room - Elevator bay at P2.F.EL |
Protrusion - visual alarm |
Dimension, depth |
6 |
AR7 |
Protruding object(s) present |
36 months |
17.2.4.6 |
Interior Other Room - Elevator bay at P2.F.EL |
Signage, Designation at door to elevators at P2.F.EL |
Dimension, height to lowest tactile text |
61.5 |
D15 |
Insufficient height - Too high |
36 months |
17.2.4.7 |
Interior Other Room - Elevator bay at P2.F.EL |
Signage, Designation at door to elevators at P2.F.EL |
Signage location |
Hinge |
D15 |
Incorrect positioning - Wrong location |
36 months |
17.2.5.1 |
Interior Other Room - Elevator bay at P3.C.EL |
Alarm System |
Dimension, height of wall mount |
76 |
AL1 |
Insufficient height - Too low |
36 months |
17.2.5.2 |
Interior Other Room - Elevator bay at P3.C.EL |
Door/Gate -Door At P3.C.EL to elevators |
Opening force |
8 |
D3 |
Excessive force - too high |
36 months |
17.2.5.3 |
Interior Other Room - Elevator bay at P3.C.EL |
Protrusion - emergency phone |
Dimension, depth |
6.75 |
AR7 |
Protruding object(s) present |
36 months |
17.2.5.4 |
Interior Other Room - Elevator bay at P3.C.EL |
Protrusion - Visual alarm near door P3.C.EL to elevators |
Dimension, depth |
6.5 |
AR7 |
Protruding object(s) present |
36 months |
17.2.5.5 |
Interior Other Room - Elevator bay at P3.C.EL |
Protrusion - Fire ext. near door P3.C.EL to elevators |
Dimension, depth |
7.5 |
AR7 |
Protruding object(s) present |
36 months |
17.2.5.6 |
Interior Other Room - Elevator bay at P3.C.EL |
Protrusion - Visual alarm in elevator bay at P3.C.EL |
Dimension, depth |
6.75 |
AR7 |
Protruding object(s) present |
36 months |
17.2.5.7 |
Interior Other Room - Elevator bay at P3.C.EL |
Signage, Designation At P3.C.EL to elevators |
Dimension, height to lowest tactile text - typical |
61.75 |
D15 |
Insufficient height - Too high |
36 months |
17.2.5.8 |
Interior Other Room - Elevator bay at P3.C.EL |
Signage, Designation At P3.C.EL to elevators |
Signage location |
Hinge |
D15 |
Incorrect positioning - Wrong location |
36 months |
17.2.6.1 |
Interior Other Room - Elevator bay at P3.F.EL |
Alarm System |
Dimension, height of wall mount |
78.5 |
AL1 |
Insufficient height - too low |
36 months |
17.2.6.2 |
Interior Other Room - Elevator bay at P3.F.EL |
Door/Gate - Door At P3.F.EL to elevators |
Closing speed |
4 |
D1 |
Too fast |
36 months |
17.2.6.3 |
Interior Other Room - Elevator bay at P3.F.EL |
Door/Gate -Door At P3.F.EL to elevators |
Opening force |
8 |
D3 |
Excessive force - too high |
36 months |
17.2.6.4 |
Interior Other Room - Elevator bay at P3.F.EL |
Protrusion - Visual alarm in elevator bay at P3.F.EL |
Dimension, depth |
5.75 |
AR7 |
Protruding object(s) present |
36 months |
17.2.6.5 |
Interior Other Room - Elevator bay at P3.F.EL |
Protrusion - Fire ext. in elevator bay at P3.F.EL |
Dimension, depth |
7.5 |
AR7 |
Protruding object(s) present |
36 months |
17.2.6.6 |
Interior Other Room - Elevator bay at P3.F.EL |
Protrusion - Emergency phone in elevator bay at P3.F.EL |
Dimension, depth |
7 |
AR7 |
Protruding object(s) present |
36 months |
17.2.6.7 |
Interior Other Room - Elevator bay at P3.F.EL |
Signage, Designation - Door At P3.F.EL to elevators |
Dimension, height to lowest tactile text |
61.25 |
D15 |
Insufficient height - too high |
36 months |
17.2.6.8 |
Interior Other Room - Elevator bay at P3.F.EL |
Signage, Designation - Door At P3.F.EL to elevators |
Signage location |
Hinge |
D15 |
Incorrect positioning - Wrong location |
36 months |
Item # |
Location Description |
Element |
Attribute |
Actual On Site Value |
Remedial Code |
Violation |
Completion Time |
18.1.1.1 |
Parking Facility Box Office & Will Call |
Parking Space - 1 |
Slope, running |
4.7 |
P4 |
Excessive slope |
48 months |
18.1.1.2 |
Parking Facility Box Office & Will Call |
Access Aisle - 1 Left |
Slope, running |
3.9 |
P4 |
Excessive slope |
48 months |
18.1.2.1 |
Parking Facility Walkway - Box Office and Will Call |
Curb Ramp |
Slope, counter |
6.5 |
AR4 |
Excessive slope |
36 months |
18.1.2.2 |
Parking Facility Walkway - Box Office and Will Call |
Curb Ramp |
Slope, landing maximum |
3.3 |
AR4 |
Excessive slope |
36 months |
18.1.3 |
Parking Facility Lower North Lot |
Parking Space |
Surface, firm and stable - Gravel lot, no accessible features, no accessible route |
No |
P4 |
Not stable, firm, and slip resistant |
48 months |
18.1.4 |
Parking Facility Lower South Lot 1 |
Parking Space - All |
Surface, firm and stable - Gravel lot. Stairs to access sidewalk by inaccessible porta potty |
No |
P4 |
Not stable, firm, and slip resistant |
48 months |
18.1.5 |
Parkig Facility Lower South Lot 2 |
Parking Space |
Surface, firm and stable - Gravel lot, porta pottys provided |
No |
P4 |
Not stable, firm, and slip resistant |
48 months |
18.1.6.1 |
Parking Facility Top Circle Lot |
Parking Space 1 |
Dimension, height of sign |
48 |
P3 |
Insufficient sign height - Too low |
24 months |
18.1.6.2 |
Parking Facility Top Circle Lot |
Parking Space 2 |
Dimension, width of gap |
4.5 |
AR5 |
Gaps present - Too wide |
24 months |
18.1.6.3 |
Parking Facility Top Circle Lot |
Parking Space 3 |
Slope, running |
3.6 |
P4 |
Excessive slope |
48 months |
18.1.6.4 |
Parking Facility Top Circle Lot |
Parking Space 4 |
Slope, running |
3.1 |
P4 |
Excessive slope |
48 months |
18.1.6.5 |
Parking Facility Top Circle Lot |
Parking Space 5 |
Slope, running |
3.1 |
P4 |
Excessive slope |
48 months |
18.1.6.6 |
Parking Facility Top Circle Lot |
Access Aisle 1-2 |
Dimension, height of level change - At gap |
1 |
AR2 |
Level change present - Too high |
48 months |
18.1.6.7 |
Parking Facility Top Circle Lot |
Access Aisle 1-2 |
Dimension, width of gap |
3 |
AR5 |
Gaps present - Too wide |
24 months |
18.1.6.8 |
Parking Facility Top Circle Lot |
Access Aisle 5-6 |
Slope, running |
3.0 |
P4 |
Excessive slope |
48 months |
18.1.7.1 |
Parking Facility Upper South Lot |
Parking Space - South of row 15 |
Slope, cross - 2.0- |
3.6 |
P4 |
Excessive slope |
48 months |
18.1.7.2 |
Parking Facility Upper South Lot |
Parking Space - South of row 15 |
Slope, running - 1.2- |
3.9 |
P4 |
Excessive slope |
48 months |
18.1.7.3 |
Parking Facility Upper South Lot |
Parking Space - North of row 23 |
Slope, cross - 1.2- |
3.3 |
P4 |
Excessive slope |
48 months |
18.1.7.4 |
Parking Facility Upper South Lot |
Parking Space - North of row 23 |
Slope, running - 2.2 |
4.3 |
P4 |
Excessive slope |
48 months |
18.1.8.1 |
Parking Facility Walkway - From spaces 1 & 2 to entry |
Landing - 1 |
Slope, running |
3.5 |
R5 |
Excessive slope |
48 months |
18.1.8.2 |
Parking Facility Walkway - From spaces 1 & 2 to entry |
Landing - L3 bottom of R3 |
Slope, running |
3.4 |
R5 |
Excessive slope |
48 months |
18.1.8.3 |
Parking Facility Walkway - From spaces 1 & 2 to entry |
Landing - L3 bottom of R3 |
Clearance, vertical - branch |
75 |
AR6 |
Insufficient vertical clearance |
48 months |
18.1.9.1 |
Parking Facility Walkway |
Ramp - At front row |
Slope, cross |
4.0 |
R1 |
Excessive slope |
48 months |
18.1.9.2 |
Parking Facility Walkway |
Ramp - At front row |
Slope, running |
10 |
R1 |
Excessive slope |
48 months |
18.1.9.3 |
Parking Facility Walkway |
Ramp - At front row |
Handrails on both sides |
No |
R2 |
Handrails are not on both sides - None provided |
24 months |
18.1.9.4 |
Parking Facility Walkway |
Door/Gate - near the grille to exterior |
Dimension, height of smooth surface |
8 |
D1 |
Insufficient smooth surface |
24 months |
18.1.9.5 |
Parking Facility Walkway |
Door/Gate - near the grille to exterior |
Opening force |
16 |
D3 |
Excessive force - Too high |
24 months |
18.1.9.6 |
Parking Facility Walkway |
Walking Surface in front of police & first aid offices |
Dimension, width - to benches |
33.5 |
AR3 |
Insufficient width - Too narrow |
48 months |
Item # |
Location Description |
Element |
Attribute |
Actual On Site Value |
Remedial Code |
Violation |
Completion Time |
18.3.1.1 |
Lower Level, South Side Walkway - Lower Level South - From Shuttle Drop-off to Front Row |
Walking Surface by First Aid |
Slope, cross |
10.4 |
AR1 |
Excessive slope |
48 months |
18.3.1.2 |
Lower Level, South Side Walkway - Lower Level South - From Shuttle Drop-off to Front Row |
Walking Surface by First Aid |
Slope, running |
11.4 |
AR1 |
Excessive slope |
48 months |
18.3.1.3 |
Lower Level, South Side Walkway - Lower Level South - From Shuttle Drop-off to Front Row |
Walking Surface by Restroom Womens |
Slope, running |
13.8 |
AR1 |
Excessive slope |
48 months |
18.3.1.4 |
Lower Level, South Side Walkway - Lower Level South - From Shuttle Drop-off to Front Row |
Walking Surface by Restroom Mens |
Slope, running |
9.0 |
AR1 |
Excessive slope |
48 months |
18.3.1.5 |
Lower Level, South Side Walkway - Lower Level South - From Shuttle Drop-off to Front Row |
Walking Surface - Bottom Ramp by 1st Row |
Slope, running |
11.7 |
AR1 |
Excessive slope |
48 months |
18.3.1.6 |
Lower Level, South Side Walkway - Lower Level South - From Shuttle Drop-off to Front Row |
Landing - Middle Landing |
Clearance, length |
51 |
R5 |
Landing length is insufficient |
48 months |
18.3.3 |
Lower Level, South Side Restroom Mens |
Signage, Destination |
Signage location |
Hinge |
D15 |
Incorrect positioning - Wrong location |
12 months |
18.3.4 |
Lower Level, South Side Restroom Mens |
Door/Gate |
Opening force - exterior |
15 |
D3 |
Excessive force - Too high |
24 months |
18.3.5 |
Lower Level, South Side Restroom Mens |
Toilet Compartment |
Handle on both sides |
No |
TR25 |
Pull is not provided on both sides |
36 months |
18.3.6 |
Lower Level, South Side Restroom Mens |
Water Closet |
Dimension, sidewall to centerline |
19 |
TR7 |
Insufficient distance - Too far |
36 months |
18.3.7 |
Lower Level, South Side Restroom Mens |
Grab Bar Side |
Dimension, height to top of grab bar |
37 |
TR19 |
Insufficient height - Too high |
12 months |
18.3.8 |
Lower Level, South Side Restroom Mens |
Dispenser, Toilet Paper - Accessible compartment |
Dimension, from water closet seat |
13 |
TR6 |
Insufficient distance - Wrong location |
12 months |
18.3.9 |
Lower Level, South Side Restroom Mens |
Ambulatory Toilet Compartment |
Handle on both sides |
No |
TR22 |
Pull is not provided on both sides |
24 months |
18.3.10 |
Lower Level, South Side Restroom Mens |
Ambulatory Toilet Compartment - Grab Bar - Right |
Dimension, height to top of grab bar |
36.75 |
TR19 |
Insufficient height - Too high |
24 months |
18.3.11 |
Lower Level, South Side Restroom Mens |
Ambulatory Toilet Compartment - Grab Bar - Left |
Dimension, height to top of grab bar |
36.75 |
TR19 |
Insufficient height - Too high |
24 months |
18.3.12 |
Lower Level, South Side Restroom Mens |
Ambulatory Toilet Compartment - Dispenser, Toilet Paper |
Dimension, from water closet seat |
13 |
TR6 |
Insufficient distance - Wrong location |
12 months |
18.3.3.1 |
Lower Level, South Side Restroom Womens |
Walking Surface |
Slope, floor drain maximum |
8.8 |
TR1 |
Excessive slope |
48 months |
18.3.3.2 |
Lower Level, South Side Restroom Womens |
Protrusion - Hand Dryer |
Dimension, depth |
6.75 |
AR7 |
Protruding object |
36 months |
18.3.3.3 |
Lower Level, South Side Restroom Womens |
Toilet Compartment |
Handle on both sides |
No |
TR25 |
Pull is not provided on both sides |
36 months |
18.3.3.4 |
Lower Level, South Side Restroom Womens |
Grab Bar Side |
Dimension, height to top of grab bar |
37 |
TR19 |
Insufficient height - Too high |
12 months |
18.3.3.5 |
Lower Level, South Side Restroom Womens |
Coat Hook |
Dimension, height |
49.5 |
TR3 |
Insufficient height - Too high |
12 months |
18.3.3.6 |
Lower Level, South Side Restroom Womens |
Ambulatory Toilet Compartment |
Handle on both sides |
No |
TR22 |
Pull is not provided on both sides |
24 months |
18.3.3.7 |
Lower Level, South Side Restroom Womens |
Ambulatory Toilet Compartment - Grab Bar - Left |
Dimension, height to top of grab bar |
36.75 |
TR19 |
Insufficient height - Too high |
24 months |
18.3.3.8 |
Lower Level, South Side Restroom Womens |
Ambulatory Toilet Compartment - Grab Bar - Right |
Dimension, height to top of grab bar |
37 |
TR19 |
Insufficient height - Too high |
24 months |
18.3.3.9 |
Lower Level, South Side Restroom Womens |
Ambulatory Toilet Compartment - Coat Hook |
Dimension, height |
49.5 |
TR3 |
Insufficient height - Too high |
12 months |
18.3.3.10 |
Lower Level, South Side Restroom Womens |
Ambulatory Toilet Compartment - Dispenser, Toilet Paper |
Dimension, from water closet seat |
5.5 |
TR6 |
Insufficient distance - Wrong location |
12 months |
18.3.3.11 |
Lower Level, South Side Restroom Womens |
Changing Station |
Clearance, perpendicular |
33 |
AR10 |
Insufficient clear floor space |
24 months |
Item # |
Location Description |
Element |
Attribute |
Actual On Site Value |
Remedial Code |
Violation |
Completion Time |
18.4.1 |
Lower Level, South Side Restroom Mens |
|
|
|
|
|
18.4.1.1 |
Lower Level, South Side Restroom Mens |
Door/Gate - Barn door, held open |
Dimension, height of vertical threshold |
0.75 |
D12 |
Threshold too high |
18.4.1.2 |
Lower Level, South Side Restroom Mens |
Door/Gate - Barn door, held open |
Slope, running |
5.4 |
D7 |
Excessive slope |
18.4.1.3 |
Lower Level, South Side Restroom Mens |
Fixture Count |
Number, accessible compartments |
0 |
TR1 |
No accessible toilet compartment |
18.4.1.4 |
Lower Level, South Side Restroom Mens |
Lavatory Sink |
Pipes protected |
No |
LS2 |
Not protected against contact - Not wrapped |
18.4.1.5 |
Lower Level, South Side Restroom Mens |
Lavatory Sink |
Dimension, height |
35.5 |
LS3 |
Insufficient height - Too high |
18.4.1.6 |
Lower Level, South Side Restroom Mens |
Dispenser, Soap |
Dimension, height of operable part |
51 |
CT3 |
Insufficient height - Too high |
18.4.1.7 |
Lower Level, South Side Restroom Mens |
Dispenser, Paper Towel |
Dimension, height of operable part |
53 |
CT3 |
Insufficient height - Too high |
18.4.1.8 |
Lower Level, South Side Restroom Mens |
Urinal |
Dimension, height to rim |
23.5 |
TR8 |
Insufficient height - Too high |
18.4.1.9 |
Lower Level, South Side Restroom Mens |
Toilet Compartment - Typical |
Dimension, side to side |
32 |
TR23 |
Insufficient clearance - Too narrow |
18.4.1.10 |
Lower Level, South Side Restroom Mens |
Toilet Compartment - Typical |
Dimension, back to front |
55.5 |
TR23 |
Insufficient depth - Insufficient clearance |
18.4.1.11 |
Lower Level, South Side Restroom Mens |
Toilet Compartment - Typical |
Door swing direction |
In |
TR12 |
Door swings into minimum toilet compartment area |
18.4.1.12 |
Lower Level, South Side Restroom Mens |
Toilet Compartment - Typical |
Restroom accessible |
No |
TR1 |
Not accessible |
18.4.1.13 |
Lower Level, South Side Restroom Mens |
Changing Station |
Dimension, height of maximum reach |
51 |
TR1 |
Insufficient height - Too high |
18.4.1.14 |
Lower Level, South Side Restroom Mens |
Changing Station |
Dimension, height to table top lip/edge |
35.5 |
DW1 |
Insufficient height - Too high |
18.4.2.1 |
Lower Level, South Side Restroom Womens |
Door/Gate |
Slope, running - Interior |
4.5 |
D7 |
Excessive slope |
18.4.2.2 |
Lower Level, South Side Restroom Womens |
Fixture Count |
Number, accessible compartments |
0 |
TR1 |
No accessible toilet compartment in restroom |
18.4.2.3 |
Lower Level, South Side Restroom Womens |
Lavatory Sink |
Pipes protected |
No |
LS2 |
Not protected against contact - Not wrapped |
18.4.2.4 |
Lower Level, South Side Restroom Womens |
Mirror |
Dimension, height to bottom |
43 |
TR5 |
Insufficient height - Too high |
18.4.2.5 |
Lower Level, South Side Restroom Womens |
Protrusion - Paper Towel dispenser and Hand dryers |
Dimension, depth |
10 |
AR7 |
Protruding object(s) present |
18.4.2.6 |
Lower Level, South Side Restroom Womens |
Toilet Compartment - Typical |
Dimension, side to side |
32 |
TR23 |
Insufficient clearance - Too narrow |
18.4.2.7 |
Lower Level, South Side Restroom Womens |
Toilet Compartment - Typical |
Dimension, back to front |
54.5 |
TR23 |
Insufficient depth - Insufficient clearance |
18.4.2.8 |
Lower Level, South Side Restroom Womens |
Toilet Compartment - Typical |
Door swing direction |
In |
TR12 |
Door swings into minimum toilet compartment area |
18.4.2.9 |
Lower Level, South Side Restroom Womens |
Toilet Compartment - Typical |
Handle on both sides |
No |
TR25 |
Pull is not provided on both sides |
18.4.2.10 |
Lower Level, South Side Restroom Womens |
Toilet Compartment - Typical |
Restroom accessible |
No |
TR1 |
Not accessible |
18.4.2.11 |
Lower Level, South Side Restroom Womens |
Changing Station |
Dimension, height of maximum reach |
51 |
TR1 |
Insufficient height - Too high |
18.4.2.12 |
Lower Level, South Side Restroom Womens |
Changing Station |
Dimension, height to table top lip/edge |
36.5 |
DW1 |
Insufficient height - Too high |
Item # |
Location Description |
Element |
Attribute |
Actual On Site Value |
Remedial Code |
Violation |
Completion Time |
18.9.1.1 |
Visitor Center Walkway - Amphitheater Visitor Center to Top Circle Lot |
Handrail, Stairs/Ramps - Info taken at L1 |
Adjacent to an abrasive surface |
Yes |
AR11 |
Surface adjacent to handrail is abrasive |
12 months |
18.9.1.2 |
Visitor Center Walkway - Amphitheater Visitor Center to Top Circle Lot |
Handrail, Stairs/Ramps - at bollards |
Continuous - 1.5" break |
No |
AR11 |
Not continuous |
12 months |
18.9.1.3 |
Visitor Center Walkway - Amphitheater Visitor Center to Top Circle Lot |
Landing - L1 at bottom handrail |
Slope, running |
3.7 |
R5 |
Excessive slope |
48 months |
18.9.1.4 |
Visitor Center Walkway - Amphitheater Visitor Center to Top Circle Lot |
Ramp - R1 |
Dimension, length - feet |
60 |
R1 |
Too long |
48 months |
18.9.1.5 |
Visitor Center Walkway - Amphitheater Visitor Center to Top Circle Lot |
Landing - L3 |
Clearance, length |
55 |
R5 |
Landing length is insufficient |
48 months |
18.9.1.6 |
Visitor Center Walkway - Amphitheater Visitor Center to Top Circle Lot |
Landing - L3 |
Slope, cross |
3.5 |
R5 |
Excessive slope |
48 months |
18.9.1.7 |
Visitor Center Walkway - Amphitheater Visitor Center to Top Circle Lot |
Ramp - R3 |
Slope, cross |
3.5 |
R1 |
Excessive slope |
48 months |
18.9.1.8 |
Visitor Center Walkway - Amphitheater Visitor Center to Top Circle Lot |
Landing - L4 |
Clearance, length |
56 |
R5 |
Landing length is insufficient |
48 months |
18.9.1.9 |
Visitor Center Walkway - Amphitheater Visitor Center to Top Circle Lot |
Ramp - R4 |
Slope, cross |
3.4 |
R1 |
Excessive slope |
48 months |
18.9.1.10 |
Visitor Center Walkway - Amphitheater Visitor Center to Top Circle Lot |
Ramp - R4 |
Slope, running |
9.2 |
R1 |
Excessive slope |
48 months |
18.9.2 |
Visitor Center Elevator |
Hall Signal |
Audible signal (1-U & 2-D) |
No |
E10 |
No audible signal |
12 months |
18.9.3 |
Visitor Center Walkway - Entrance on 2nd Level |
Door/Gate |
Dimension, width of gap |
Gaps in flagstone |
AR5 |
Gaps present - Too wide |
24 months |
18.9.4 |
Visitor Center 1st Floor - Suite Room |
Operable Part - closet rod |
Dimension, height |
60.75 |
CT3 |
Insufficient height - Too high |
24 months |
18.9.5.1 |
Visitor Center 1st Floor - The Grille |
Food Service/Buffet - Forward - Bar |
Dimension, height - Whole bar surface |
42.25 |
DW1 |
Insufficient height - Too high |
12 months |
18.9.5.2 |
Visitor Center 1st Floor - The Grille |
Dining Surface - Tables |
Dimension, depth of knee clearance at 27" |
Knee depth blocked by pedestals or legs |
DW1 |
Insufficient clearance |
48 months |
18.9.6.1 |
Visitor Center 1st Floor Hallway - By Womens RR |
Vending Machine - Snack |
Dimension, height of maximum reach |
50.75 |
CT1 |
Outside of reach range |
24 months |
18.9.6.2 |
Visitor Center 1st Floor Hallway - By Womens RR |
Vending Machine - Snack |
Dimension, height of lowest reach |
11 |
CT1 |
Outside of reach range |
24 months |
18.9.7.1 |
Visitor Center 1st Floor Hallway - Interactive Hall |
Interactive Hall - Protrusion - Screens |
Dimension, depth |
12 |
AR7 |
Protruding object(s) present |
36 months |
18.9.7.2 |
Visitor Center 1st Floor Hallway - Interactive Hall |
Interactive Hall - Protrusion - Display Cases |
Dimension, depth |
9.5 |
AR7 |
Protruding object(s) present |
36 months |
18.9.8.1 |
Visitor Center 1st Floor Lobby - North |
ATM/Fare Machine |
Braille instructions provided - Touch Screen with Keypad |
No |
AT1 |
No Braille instructions |
24 months |
18.9.8.2 |
Visitor Center 1st Floor Lobby - North |
Operable Part - post cards |
Dimension, height |
67 |
CT3 |
Insufficient height - Too high |
24 months |
18.9.8.3 |
Visitor Center 1st Floor Lobby - North |
Operable Part - souvenir pennies |
Dimension, height |
50.5 |
CT3 |
Insufficient height - Too high |
24 months |
18.9.8.4 |
Visitor Center 1st Floor Lobby - North |
Operable Part - collectable medallions |
Dimension, height |
59 |
CT3 |
Insufficient height - Too high |
24 months |
18.9.8.5 |
Visitor Center 1st Floor Lobby - North |
Drinking Fountain Interior - By Mens |
Dimension, height of flow above water outlet |
3 |
DF5 |
Insufficient height - Too low |
36 months |
18.9.9.1 |
Visitor Center 1st Floor Restroom Mens - North |
Protrusion |
Dimension, depth |
6.75 |
AR7 |
Protruding object(s) present |
36 months |
18.9.9.2 |
Visitor Center 1st Floor Restroom Mens - North |
Fixture Count |
Number, ambulatory compartments |
0 |
TR22 |
No ambulatory compartment provided |
48 months |
18.9.9.3 |
Visitor Center 1st Floor Restroom Mens - North |
Toilet Compartment - Front |
Dimension, back to front |
58 |
TR23 |
Insufficient depth - Insufficient clearance |
48 months |
18.9.9.4 |
Visitor Center 1st Floor Restroom Mens - North |
Toilet Compartment - Front |
Dimension, height of toe clearance - Front |
0 |
TR23 |
Not provided - Too low |
36 months |
18.9.9.5 |
Visitor Center 1st Floor Restroom Mens - North |
Toilet Compartment - Front |
Obstruction present |
Trash cans block clearance in all toilet compartments |
TR24 |
Obstruction present - clearance is obstructed |
36 months |
18.9.9.6 |
Visitor Center 1st Floor Restroom Mens - North |
Grab Bar Rear - Front |
12" from centerline on narrow side |
No |
TR14 |
Insufficient distance |
12 months |
18.9.9.7 |
Visitor Center 1st Floor Restroom Mens - North |
Grab Bar Side - Front |
Dimension, height to top of grab bar |
36.5 |
TR19 |
Insufficient height - Too high |
12 months |
18.9.9.8 |
Visitor Center 1st Floor Restroom Mens - North |
Dispenser, Toilet Paper - Front |
Dimension, from water closet seat |
11 |
TR6 |
Insufficient distance - Wrong location |
12 months |
18.9.9.9 |
Visitor Center 1st Floor Restroom Mens - North |
Toilet Compartment - Rear |
Clearance, door opening width |
31.25 |
TR23 |
Insufficient width - Too narrow |
36 months |
18.9.9.10 |
Visitor Center 1st Floor Restroom Mens - North |
Toilet Compartment - Rear |
Dimension, back to front |
57.75 |
TR23 |
Insufficient depth - Insufficient clearance |
48 months |
18.9.9.11 |
Visitor Center 1st Floor Restroom Mens - North |
Toilet Compartment - Rear |
Dimension, height of toe clearance - Front |
0 |
TR23 |
Not provided - Too low |
36 months |
18.9.9.12 |
Visitor Center 1st Floor Restroom Mens - North |
Water Closet - Rear |
Dimension, sidewall to centerline |
19.5 |
TR7 |
Insufficient distance - Too far |
36 months |
18.9.9.13 |
Visitor Center 1st Floor Restroom Mens - North |
Grab Bar Side - Rear |
Dimension, height to top of grab bar |
36.5 |
TR19 |
Insufficient height - Too high |
12 months |
18.9.9.14 |
Visitor Center 1st Floor Restroom Mens - North |
Coat Hook - Rear |
Dimension, height |
70 |
TR3 |
Insufficient height - Too high |
12 months |
18.9.9.15 |
Visitor Center 1st Floor Restroom Mens - North |
Changing Station - Front |
Clearance, perpendicular |
35 |
AR10 |
Insufficient clear floor space |
24 months |
18.9.9.16 |
Visitor Center 1st Floor Restroom Mens - North |
Changing Station - Front |
Dimension, height to table top lip/edge |
37 |
DW1 |
Insufficient height - Too high |
24 months |
18.9.9.17 |
Visitor Center 1st Floor Restroom Mens - North |
Changing Station - Rear |
Clearance, perpendicular |
34 |
AR10 |
Insufficient clear floor space |
24 months |
18.9.9.18 |
Visitor Center 1st Floor Restroom Mens - North |
Changing Station - Rear |
Dimension, height to table top lip/edge |
36 |
DW1 |
Insufficient height - Too high |
24 months |
18.9.10.1 |
Visitor Center 1st Floor Restroom Mens - South |
Signage, Designation - Baby Change |
Dimension, height to highest tactile text |
47.5 |
TR11 |
Insufficient height - Too high |
12 months |
18.9.10.2 |
Visitor Center 1st Floor Restroom Mens - South |
Door/Gate |
Clearance, pull perpendicular |
58.5 |
D5 |
Insufficient clearance |
24 months |
18.9.10.3 |
Visitor Center 1st Floor Restroom Mens - South |
Door/Gate |
Opening force |
12 |
D3 |
Excessive force - Too high |
24 months |
18.9.10.4 |
Visitor Center 1st Floor Restroom Mens - South |
Protrusion - Hand Dryer |
Dimension, depth |
6.75 |
AR7 |
Protruding object(s) present |
36 months |
18.9.10.5 |
Visitor Center 1st Floor Restroom Mens - South |
Fixture Count |
Number, ambulatory compartments |
0 |
TR22 |
No ambulatory compartment provided |
48 months |
18.9.10.6 |
Visitor Center 1st Floor Restroom Mens - South |
Toilet Compartment |
Clearance, door opening width |
31 |
TR23 |
Insufficient width - Too narrow |
36 months |
18.9.10.7 |
Visitor Center 1st Floor Restroom Mens - South |
Toilet Compartment |
Dimension, height of toe clearance - Front |
0 |
TR23 |
Not provided - Too low |
36 months |
18.9.10.8 |
Visitor Center 1st Floor Restroom Mens - South |
Grab Bar Side |
Dimension, height to top of grab bar |
36.25 |
TR19 |
Insufficient height - Too high |
12 months |
18.9.10.9 |
Visitor Center 1st Floor Restroom Mens - South |
Changing Station |
Clearance, perpendicular |
34 |
AR10 |
Insufficient clear floor space |
24 months |
18.9.10.10 |
Visitor Center 1st Floor Restroom Mens - South |
Changing Station |
Dimension, height to table top lip/edge |
36 |
DW1 |
Insufficient height - Too high |
24 months |
18.9.11.1 |
Visitor Center 1st Floor Restroom Womens - North |
Signage, Designation - Baby Change Sign |
Dimension, height to highest tactile text |
47.25 |
TR11 |
Insufficient height - Too low |
12 months |
18.9.11.2 |
Visitor Center 1st Floor Restroom Womens - North |
Door/Gate |
Closing speed |
4 |
D1 |
Too fast |
24 months |
18.9.11.3 |
Visitor Center 1st Floor Restroom Womens - North |
Door/Gate |
Opening force |
8 |
D3 |
Excessive force - Too high |
24 months |
18.9.11.4 |
Visitor Center 1st Floor Restroom Womens - North |
Fixture Count |
Number, ambulatory compartments |
0 |
TR22 |
No ambulatory compartment provided |
48 months |
18.9.11.5 |
Visitor Center 1st Floor Restroom Womens - North |
Toilet Compartment - Rear Left |
Clearance, door opening width |
31 |
TR23 |
Insufficient width - Too narrow |
36 months |
18.9.11.6 |
Visitor Center 1st Floor Restroom Womens - North |
Toilet Compartment - Rear Left |
Dimension, back to front |
58.25 |
TR23 |
Insufficient depth - Insufficient clearance |
48 months |
18.9.11.7 |
Visitor Center 1st Floor Restroom Womens - North |
Toilet Compartment - Rear Left |
Dimension, height of toe clearance - Front |
0 |
TR23 |
Not provided - Too low |
36 months |
18.9.11.8 |
Visitor Center 1st Floor Restroom Womens - North |
Grab Bar Side - Rear Left |
Dimension, height to top of grab bar |
36.5 |
TR19 |
Insufficient height - Too high |
12 months |
18.9.11.9 |
Visitor Center 1st Floor Restroom Womens - North |
Toilet Compartment - Rear Right |
Clearance, door opening width |
31.25 |
TR23 |
Insufficient width - Too narrow |
36 months |
18.9.11.10 |
Visitor Center 1st Floor Restroom Womens - North |
Toilet Compartment - Rear Right |
Dimension, side to side |
58 |
TR23 |
Insufficient clearance - Too narrow |
48 months |
18.9.11.11 |
Visitor Center 1st Floor Restroom Womens - North |
Toilet Compartment - Rear Right |
Dimension, height of toe clearance - Front |
0 |
TR23 |
Not provided - Too low |
36 months |
18.9.11.12 |
Visitor Center 1st Floor Restroom Womens - North |
Grab Bar Side - Rear Right |
Dimension, height to top of grab bar |
36.5 |
TR19 |
Insufficient height - Too high |
12 months |
18.9.11.13 |
Visitor Center 1st Floor Restroom Womens - North |
Toilet Compartment - Rear Right 1st |
Clearance, door opening width |
31.25 |
TR23 |
Insufficient width - Too narrow |
36 months |
18.9.11.14 |
Visitor Center 1st Floor Restroom Womens - North |
Toilet Compartment - Rear Right 1st |
Dimension, back to front |
58 |
TR23 |
Insufficient depth - Insufficient clearance |
48 months |
18.9.11.15 |
Visitor Center 1st Floor Restroom Womens - North |
Toilet Compartment - Rear Right 1st |
Dimension, height of toe clearance - Front |
0 |
TR23 |
Not provided - Too low |
36 months |
18.9.11.16 |
Visitor Center 1st Floor Restroom Womens - North |
Grab Bar Side - Rear Right 1st |
Dimension, height to top of grab bar |
36.75 |
TR19 |
Insufficient height - Too high |
12 months |
18.9.11.17 |
Visitor Center 1st Floor Restroom Womens - North |
Toilet Compartment - Front Left |
Dimension, back to front |
58.5 |
TR23 |
Insufficient depth - Insufficient clearance |
48 months |
18.9.11.18 |
Visitor Center 1st Floor Restroom Womens - North |
Toilet Compartment - Front Left |
Dimension, height of toe clearance - Front |
0 |
TR23 |
Not provided - Too low |
36 months |
18.9.11.19 |
Visitor Center 1st Floor Restroom Womens - North |
Grab Bar Side |
Dimension, height to top of grab bar |
36.75 |
TR19 |
Insufficient height - Too high |
12 months |
18.9.11.20 |
Visitor Center 1st Floor Restroom Womens - North |
Protrusion - Hand Dryer |
Dimension, depth |
6.75 |
AR7 |
Protruding object(s) present |
36 months |
18.9.11.21 |
Visitor Center 1st Floor Restroom Womens - North |
Changing Station |
Clearance, perpendicular |
36.5 |
AR10 |
Insufficient clear floor space |
24 months |
18.9.11.22 |
Visitor Center 1st Floor Restroom Womens - North |
Changing Station - Rear Left |
Dimension, height to table top lip/edge |
35.5 |
DW1 |
Insufficient height - Too high |
24 months |
18.9.11.23 |
Visitor Center 1st Floor Restroom Womens - North |
Changing Station - Rear Right |
Clearance, perpendicular |
45 |
AR10 |
Insufficient clear floor space |
24 months |
18.9.12.1 |
Visitor Center 1st Floor Women's Restroom - South |
Signage, Designation - Baby Change |
Dimension, height to highest tactile text |
47.5 |
TR11 |
Insufficient height - Too high |
12 months |
18.9.12.2 |
Visitor Center 1st Floor Women's Restroom - South |
Door/Gate |
Opening force |
15 |
D3 |
Excessive force - Too high |
24 months |
18.9.12.3 |
Visitor Center 1st Floor Women's Restroom - South |
Protrusion - Hand Dryer |
Dimension, depth |
6.75 |
AR7 |
Protruding object(s) present |
36 months |
18.9.12.4 |
Visitor Center 1st Floor Women's Restroom - South |
Fixture Count |
Number, ambulatory compartments |
0 |
TR22 |
No ambulatory compartment provided |
48 months |
18.9.12.5 |
Visitor Center 1st Floor Women's Restroom - South |
Toilet Compartment Front |
Dimension, back to front |
57.75 |
TR23 |
Insufficient depth - Insufficient clearance |
48 months |
18.9.12.6 |
Visitor Center 1st Floor Women's Restroom - South |
Water Closet - Front |
Dimension, sidewall to centerline |
15 |
TR7 |
Insufficient distance - Too close |
36 months |
18.9.12.7 |
Visitor Center 1st Floor Women's Restroom - South |
Grab Bar Rear - Front |
12" from centerline on narrow side |
No |
TR14 |
Insufficient distance |
12 months |
18.9.12.8 |
Visitor Center 1st Floor Women's Restroom - South |
Grab Bar Side - Front |
Dimension, height to top of grab bar |
36.5 |
TR19 |
Insufficient height - Too high |
12 months |
18.9.12.9 |
Visitor Center 1st Floor Women's Restroom - South |
Dispenser, Toilet Paper - Front |
Dimension, from water closet seat |
1 |
TR6 |
Insufficient distance - Wrong location |
12 months |
18.9.12.10 |
Visitor Center 1st Floor Women's Restroom - South |
Changing Station - Front |
Clearance, perpendicular |
40.5 |
AR10 |
Insufficient clear floor space |
24 months |
18.9.12.11 |
Visitor Center 1st Floor Women's Restroom - South |
Toilet Compartment - Rear |
Dimension, back to front |
57.75 |
TR23 |
Insufficient depth - Insufficient clearance |
48 months |
18.9.12.12 |
Visitor Center 1st Floor Women's Restroom - South |
Toilet Compartment - Rear |
Dimension, height of toe clearance - Front |
0 |
TR23 |
Not provided - Too low |
36 months |
18.9.12.13 |
Visitor Center 1st Floor Women's Restroom - South |
Grab Bar Side - Rear |
Dimension, height to top of grab bar |
36.5 |
TR19 |
Insufficient height - Too high |
12 months |
18.9.12.14 |
Visitor Center 1st Floor Women's Restroom - South |
Changing Station - Rear |
Clearance, perpendicular |
36 |
AR10 |
Insufficient clear floor space |
24 months |
18.9.12.15 |
Visitor Center 1st Floor Women's Restroom - South |
Changing Station - Rear |
Dimension, height to table top lip/edge |
36 |
DW1 |
Insufficient height - Too high |
24 months |
Item # |
Location Description |
Element |
Attribute |
Actual On Site Value |
Remedial Code |
Violation |
Completion Time |
18.10.1.1 |
Trading Post Parking Facility - Trading Post & Colorado Music Hall of Fame |
Parking Space - 1 |
Slope, running |
3.3 |
P4 |
Excessive slope |
48 months |
18.10.1.2 |
Trading Post Parking Facility - Trading Post & Colorado Music Hall of Fame |
Parking Space - 3 |
Dimension, height of sign |
43 |
P3 |
Insufficient sign height - Too low |
24 months |
18.10.1.3 |
Trading Post Parking Facility - Trading Post & Colorado Music Hall of Fame |
Parking Space - 3 |
Slope, cross |
3.6 |
P4 |
Excessive slope |
48 months |
18.10.1.4 |
Trading Post Parking Facility - Trading Post & Colorado Music Hall of Fame |
Access Aisle - 3 right |
Slope, cross |
9.9 |
P4 |
Excessive slope |
48 months |
18.10.1.5 |
Trading Post Parking Facility - Trading Post & Colorado Music Hall of Fame |
Access Aisle - 3 right |
Slope, running |
3.9 |
P4 |
Excessive slope |
48 months |
18.10.1.6 |
Trading Post Parking Facility - Trading Post & Colorado Music Hall of Fame |
Access Aisle - 3 right |
Dimension, height of level change |
0.5 |
AR2 |
Level change present - Too high |
48 months |
18.10.1.7 |
Trading Post Parking Facility - Trading Post & Colorado Music Hall of Fame |
Access Aisle - 3 right |
Dimension, width of gap |
1 |
AR5 |
Gaps present - Too wide |
24 months |
18.10.2.1 |
Trading Post Walkway |
Walking Surface from main room to class of 2011 room |
Slope, running |
14.7 |
AR1 |
Excessive slope |
48 months |
18.10.2.2 |
Trading Post Walkway |
Walking Surface from main area to class of 2012 room |
Slope, running |
18.4 |
AR1 |
Excessive slope |
48 months |
18.10.2.3 |
Trading Post Walkway |
Walking Surface in between clothing racks |
Dimension, width |
30 |
AR3 |
Insufficient width - Too narrow |
48 months |
18.10.2.4 |
Trading Post Walkway |
Ramp at Colorado getaway |
Handrails on both sides |
No |
R2 |
Handrails are not on both sides |
24 months |
18.10.2.5 |
Trading Post Walkway |
Door/Gate to observation deck |
Clearance, pull parallel |
0 |
D5 |
Insufficient clearance |
24 months |
18.10.2.6 |
Trading Post Walkway |
Door/Gate to observation deck |
Closing speed |
4 |
D1 |
Too fast |
24 months |
18.10.2.7 |
Trading Post Walkway |
Door/Gate to observation deck |
Dimension, height of vertical threshold |
2 |
D12 |
Threshold too high |
24 months |
18.10.2.8 |
Trading Post Walkway |
Door/Gate to observation deck |
Opening force |
7 |
D3 |
Excessive force - Too high |
24 months |
18.10.2.9 |
Trading Post Walkway |
Door/Gate to observation deck |
Fixed door stop provided |
Yes |
D1 |
Insufficient smooth surface - Door stop is located in smooth surface of door |
24 months |
18.10.3.1 |
Trading Post Hallway |
Protrusion - Drinking Fountain |
Dimension, depth |
12.5 |
AR7 |
Protruding object(s) present |
36 months |
18.10.3.2 |
Trading Post Hallway |
Door/Gate to exterior from restroom |
Closing speed |
4 |
D1 |
Too fast |
24 months |
18.10.3.3 |
Trading Post Hallway |
Door/Gate to exterior from restroom |
Opening force |
10 |
D3 |
Excessive force - Too high |
24 months |
18.10.4.1 |
Trading Post Restroom Mens |
Grab Bar Side |
Dimension, height to top of grab bar |
36.75 |
TR19 |
Insufficient height - Too high |
12 months |
18.10.4.2 |
Trading Post Restroom Mens |
Dispenser, Toilet Paper |
Dimension, from water closet seat |
11 |
TR6 |
Insufficient distance - Wrong location |
12 months |
18.10.4.3 |
Trading Post Restroom Mens |
Door/Gate |
Clearance, pull parallel - Rock Wall |
10.5 |
D5 |
Insufficient clearance |
24 months |
18.10.4.4 |
Trading Post Restroom Mens |
Door/Gate |
Closing speed |
4 |
D1 |
Too fast |
24 months |
18.10.4.5 |
Trading Post Restroom Mens |
Door/Gate |
Opening force |
7 |
D3 |
Excessive force - Too high |
24 months |
18.10.5.1 |
Trading Post Restroom Unisex - Accessible Restroom |
Signage, Designation |
Braille provided |
No |
D15 |
Braille not provided |
12 months |
18.10.5.2 |
Trading Post Restroom Unisex - Accessible Restroom |
Door/Gate |
Clearance, door opening width |
30 |
D14 |
Insufficient width - Too narrow |
24 months |
18.10.5.3 |
Trading Post Restroom Unisex - Accessible Restroom |
Protrusion - Paper Towel dispenser and Hand dryers |
Dimension, depth |
9.5 |
AR7 |
Protruding object(s) present |
36 months |
18.10.5.4 |
Trading Post Restroom Unisex - Accessible Restroom |
Lavatory Sink |
Pipes protected |
No |
LS2 |
Not protected against contact - Not wrapped |
36 months |
18.10.5.5 |
Trading Post Restroom Unisex - Accessible Restroom |
Lavatory Sink |
Clearance, perpendicular -toilet |
39 |
LS5 |
Insufficient clear floor space |
36 months |
18.10.5.6 |
Trading Post Restroom Unisex - Accessible Restroom |
Lavatory Sink |
Hardware operable |
No |
LS4 |
Requires tight grasping, pinching, or twisting of the wrist |
36 months |
18.10.5.7 |
Trading Post Restroom Unisex - Accessible Restroom |
Water Closet |
Clearance, parallel - sink |
46.25 |
TR24 |
Insufficient clearance |
48 months |
18.10.5.8 |
Trading Post Restroom Unisex - Accessible Restroom |
Changing Station |
Dimension, height of maximum reach |
51 |
TR1 |
Insufficient height - Too high |
24 months |
18.10.5.9 |
Trading Post Restroom Unisex - Accessible Restroom |
Changing Station |
Dimension, height to table top lip/edge |
39.75 |
DW1 |
Insufficient height - Too high |
24 months |
18.10.6.1 |
Trading Post Restroom Womens - Lower Level |
Door/Gate |
Closing speed |
3.5 |
D1 |
Too fast |
24 months |
18.10.6.2 |
Trading Post Restroom Womens - Lower Level |
Door/Gate |
Opening force |
8 |
D3 |
Excessive force - Too high |
24 months |
18.10.6.3 |
Trading Post Restroom Womens - Lower Level |
Grab Bar Side |
Dimension, height to top of grab bar |
36.5 |
TR19 |
Insufficient height - Too high |
12 months |
18.10.6.4 |
Trading Post Restroom Womens - Lower Level |
Dispenser, Toilet Paper |
Dimension, from water closet seat |
11 |
TR6 |
Insufficient distance - Wrong location |
12 months |
18.10.6.5 |
Trading Post Restroom Womens - Lower Level |
Protrusion - Paper Towel dispenser and Hand dryer |
Dimension, depth |
8 |
AR7 |
Protruding object(s) present |
36 months |