ATTACHMENT J: Modifications to Altered Facilities

Please Note: Paragraph 53 of the Settlement Agreement requires that within three months of the effective date of this Agreement, the County provide signage as necessary to comply with 28 C.F.R. §35.163(b), after having surveyed all facilities that are the subject of this Agreement for the purpose of identifying those that have multiple entrances not all of which are accessible.

The chart below lists the facilities surveyed by the Department, the access issues identified during the survey, and the actions required to correct the access issues. Required actions are listed using an alphanumeric code.

The key to the alphanumeric codes is provided in Attachment M to this Agreement. In order to ensure that the following spaces and elementsin the County’s facilities in which alterations occurred after January 26, 1992, are readily accessible to and usable by persons with disabilities, the County will take the actions referenced by the alphanumeric code and described in detail in Attachment M to this Settlement Agreement within the time period specified below, which time period will begin to run on the effective date of this Agreement.

Item #

Access Issue

Required Action

Completion Date

1.

Judicial Center, located at 100 East 2nd Street, Owensboro    

1.1.

Permanent Room Signage: The signage provided throughout the facility is inaccessible because it is generally mounted on the door to the room and it does not have raised and Braille characters. D26 30 months

1.2.

Interior Doors: The interior doors throughout the facility are inaccessible because they require more than 5 pounds of force to open. D2 12 months

1.3.

Juvenile Courtroom (1st Floor) (existing)    

1.3.a.

The route is inaccessible because it is only 27 inches wide between the front bench and the witness box. AR3 24 months

1.3.b.

The courtroom, containing 24 seats, is inaccessible because there is no wheelchair seating area provided. A total of one wheelchair seating area is required. AA6 30 months

1.3.c.

The courtroom is inaccessible to people with hearing disabilities because there is no assistive listening system provided. AA5 30 months

1.4.

District Courtroom - Traffic and Misdemeanors (1st Floor) (existing)    

1.4.a.

The courtroom, containing 225 seats, is inaccessible because there are no wheelchair seating area are provided. A total of 4 wheelchair seating areas is required. AA6 30 months

1.4.b.

The courtroom is inaccessible to people with hearing disabilities because, although there are 225 fixed seats, there is no assistive listening system provided. This courtroom requires 9 receivers. AA4 30 months

1.5.

District Courtrooms I and II (2nd Floor) (existing)    

1.5.a.

The courtrooms, containing 50 seats each, are inaccessible because there are no wheelchair seating areas provided. A total of 2 wheelchair seating areas is required in each courtroom. AA6 30 months

1.5.b.

The courtrooms are inaccessible to people with hearing disabilities because, although there are 50 fixed seats, there is no assistive listening system provided. These courtrooms each require 2 receivers. AA4 30 months

1.6.

Circuit Courtrooms Division I and II (4th Floor) (existing)    

1.6.a.

The courtrooms, containing 72 seats each, are inaccessible because there are no wheelchair seating areas provided. A total of 4 wheelchair seating areas is required in each courtroom. AA6 30 months

1.6.b.

The courtrooms are inaccessible to people with hearing disabilities because, although there are 72 fixed seats, there is no assistive listening system provided. These courtrooms each require 3 receivers. AA4 30 months

1.7.

Holding Cells (existing): The holding cells and toilet rooms in secure areas throughout the facility have standard toilets and lavatories that are not accessible to persons with disabilities. TR7 30 months

1.8.

Traffic Court Clerk’s Office Counters (existing): The counters protrude into the walkway and are not detectable to blind persons using a cane. AR8 24 months

1.9.

Commonwealth Attorney’s Office Door (existing): The pull side of the door on the main hallway, which is accessed through a front approach, is inaccessible because it has only 16 inches of clear space on the latch side. D6 30 months

1.10.

Law Library (3rd Floor) (existing): The telephone is inaccessible because it is 61¾ inches high to the highest operable part. TT1 12 months

1.11.

Single-User Toilet Rooms for District Courtrooms I and II Jury Rooms (2nd Floor) (existing)    

1.11.a.

The push side of the door to each of the toilet rooms, which is accessed through a front approach and which has both a closer and a latch, is inaccessible because it has only 6 inches of clear space on the latch side. D7 30 months

1.11.b.

The toilet room doors swing into the required clear floor space at the lavatories and toilets. TR6 30 months

1.11.c.

No accessible coat hook has been provided. TR1 12 months

1.11.d.

No accessible mirror has been provided. TR14 12 months

1.11.e.

Each toilet room is inaccessible because there is insufficient turning space provided within the room. TR19 30 months

1.11.f.

The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact. TR12 24 months

1.11.g.

The toilet is inaccessible because there is insufficient clear floor space provided. SU16 30 months

1.11.h.

The toilet seat cover dispenser is inaccessible because it is mounted 55 inches high behind the toilet. TR4 12 months

1.11.i.

The toilet is inaccessible because the flush control is on the closed side. SU1 30 months

1.11.j.

The toilet is inaccessible because there are no grab bars provided. SU10 30 months

1.12.

Men’s Single-User Toilet Room in Grand Jury Room (3rd Floor) (existing)    

1.12.a.

The toilet room sign is mounted on the door, has no raised or Braille characters, and has no International Symbol of Accessibility. TR17 24 months

1.12.b.

The door is inaccessible because it has an opening width of 29 inches. D25 29 months

1.12.c.

The toilet room door swings into the required clear floor space at the lavatory and the toilet. TR6 30 months

1.12.d.

No accessible coat hook has been provided. TR1 12 months

1.12.e.

No accessible mirror has been provided. TR14 12 months

1.12.f.

The paper towel dispenser is inaccessible because it is mounted with the controls 64 inches high. TR5 12 months

1.12.g.

The toilet room is inaccessible because there is insufficient turning space provided within the room. TR19 30 months

1.12.h.

The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact. TR12 24 months

1.12.i.

The toilet is inaccessible because there is insufficient clear floor space provided. SU16 30 months

1.12.j.

The toilet is inaccessible because there are no grab bars provided. SU10 30 months

1.13.

Women’s Single-User Toilet Room in Grand Jury Room (3rd Floor) (existing)    

1.13.a.

The toilet room sign is mounted on the door, has no raised or Braille characters, and has no International Symbol of Accessibility. TR17 24 months

1.13.b.

The door is inaccessible because it has an opening width of 29 inches. D25 30 months

1.13.c.

The push side of the door, which is accessed through a front approach and which has both a closer and a latch, is inaccessible because it has only 4 inches of clear space on the latch side. D7 30 months

1.13.d.

The toilet room door swings into the required clear floor space at the lavatory and the toilet. TR6 30 months

1.13.e.

No accessible coat hook has been provided. TR1 12 months

1.13.f.

No accessible mirror has been provided. TR14 12 months

1.13.g.

The paper towel dispenser is inaccessible because it is mounted with the controls 64 inches high. TR5 12 months

1.13.h.

The toilet room is inaccessible because there is insufficient turning space provided within the room. TR19 30 months

1.13.i.

The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact. TR12 24 months

1.13.j.

The toilet is inaccessible because there is insufficient clear floor space provided. SU16 30 months

1.13.k.

The toilet is inaccessible because there are no grab bars provided. SU10 30 months

1.14.

Single-User Toilet Rooms for Circuit Courtroom Division I and II Jury Rooms (4th Floor) (existing)    

1.14.a.

The toilet room signs are mounted on the door, have no raised or Braille characters, and have no International Symbol of Accessibility. TR17 24 months

1.14.b.

The doors are inaccessible because they have an opening width of 29 inches. D25 30 months

1.14.c.

No accessible coat hook has been provided. TR1 12 months

1.14.d.

No accessible mirror has been provided (except in the right-side toilet room in the jury room for Circuit Courtroom Division II). TR14 12 months

1.14.e.

The paper towel dispenser is inaccessible because it is mounted with the controls 63 inches high. TR5 12 months

1.14.f.

Where provided, the toilet seat cover dispensers are inaccessible because they are mounted more than 54 inches high behind the toilet. TR4 12 months

1.14.g.

Each toilet room is inaccessible because there is insufficient turning space provided within the room. TR19 30 months

1.14.h.

The lavatories are inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact. TR12 24 months

1.14.i.

The toilets are inaccessible because there is insufficient clear floor space provided. SU16 30 months

1.14.j.

The toilet paper dispensers are inaccessible because they are mounted less than 19 inches high. SU17 12 months

1.14.k.

The toilets are inaccessible because there are no grab bars provided. SU10 30 months

1.15.

Employee Single-User Toilet Room near Main Entrance (1st Floor)    

1.15.a.

No accessible coat hook has been provided. TR1 12 months

1.15.b.

The side grab bar at the toilet is inaccessible because it is mounted with the far end less than 54 inches from the rear wall. SU5 12 months

1.15.c.

The rear grab bar at the toilet is inaccessible because it is obstructed by the toilet seat cover dispenser and soap dispenser. SU4 12 months

1.16.

Men’s Toilet Room With Stalls Near Concessions (1st Floor) (existing)    

1.16.a.

The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact. TR12 24 months

1.16.b.

The side grab bar at the designated accessible toilet is inaccessible because it is mounted with the far end 48 inches from the rear wall. ST7 12 months

1.16.c.

The air dryers protrude into the walkway and are not detectable to blind persons using a cane. AR8 12 months

1.17.

Women’s Toilet Room With Stalls Near Concessions (1st Floor) (existing)    

1.17.a.

The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact. TR12 24 months

1.17.b.

The lavatory is inaccessible because it lacks adequate clear floor space. TR8 30 months

1.17.c.

The designated accessible toilet is inaccessible because the flush control is on the closed side. ST2 30 months

1.17.d.

No accessible coat hook has been provided. TR1 12 months

1.17.e.

The side grab bar at the designated accessible toilet is inaccessible because it is mounted with the far end 48 inches from the rear wall. ST7 12 months

1.17.f.

The designated accessible toilet is inaccessible because the rear grab bar is obstructed. ST5 12 months

1.17.g.

The toilet seat cover dispenser is inaccessible because it is mounted 51 inches high and requires a forward reach. TR4 6 months

1.18.

Men’s Toilet Room With Stalls (2nd, 3rd, and 4th Floors) (existing): The toilet rooms lack accessible directional signage with the International Symbol of Accessibility at inaccessible toilet rooms indicating the location of the nearest accessible toilet room, and accessible signage with the International Symbol of Accessibility at all accessible toilet rooms. TR16 24 months

1.19.

Women’s Toilet Room With Stalls (2nd, 3rd, and 4th Floors) (existing): The toilet rooms lack accessible directional signage with the International Symbol of Accessibility at inaccessible toilet rooms indicating the location of the nearest accessible toilet room, and accessible signage with the International Symbol of Accessibility at all accessible toilet rooms. TR16 24 months

1.20.

Public Elevator (existing). The elevator is inaccessible because the emergency system requires tight grasping or pinching to access. E8 24 months

1.21.

Drinking Fountain Between Public Restrooms (2nd Floor)    

1.21.a.

The drinking fountain is inaccessible because the controls require 15 pounds of force to operate. DF2 12 months

1.21.b.

Although a designated accessible drinking fountain is provided, there is no drinking fountain provided for people who have difficulty bending or stooping. DF3 24 months

1.21.c.

The drinking fountain protrudes into the walkway and is not detectable to blind persons using a cane. AR8 12 months

1.22.

Drinking Fountain in Hallway Near Drug Court (3rd Floor)    

1.22.a.

The drinking fountain is inaccessible because the flow of water is less than 4 inches high. DF7 12 months

1.22.b.

The drinking fountain is inaccessible because the control requires 17 pounds of force to operate. DF2 12 months

1.23.

Drinking Fountain in Courtroom II Jury Room (4th Floor): The drinking fountain is inaccessible because the flow of water is less than 4 inches high. DF7 12 months

1.24.

Public Telephone Near Security (1st Floor)    

1.24.a.

The telephone is inaccessible because it is 63 inches high to the highest operable part and there is no volume control. TT1 24 months

1.24.b.

The telephone protrudes into the walkway and is not detectable to blind persons using a cane. AR8 24 months

1.25.

Public Telephone in Hallway (2nd Floor): The telephone is inaccessible because there is inadequate clear floor space and it is 60 inches high to the highest operable part. TT1 30 months

1.26.

Public Telephone in Hallway (4th Floor):    

1.26.a.

The telephone is inaccessible because it has no volume control. TT1 30 months

1.26.b.

The telephone protrudes into the walkway and is not detectable to blind persons using a cane. AR8 30 months

1.27.

Ashtrays: The ashtrays located throughout the Judicial Center protrude into the walkway and is not detectable to blind persons using a cane. AR8 30 months

1.28.

Alarms: Although the facility contains an emergency alarm system, the alarm system is inaccessible because visual alarms are not provided in all general usage areas or in toilet rooms. AL1 30 months

2.

Panther Creek Park, 5160 Wayne Bridge Road, Owensboro    

2.1.

Parking    

2.1.a.

The parking lot is inaccessible because two of the four spaces designated as accessible are less than 96 inches wide and all four lack appropriate vertical signage. P3 30 months

2.1.b.

The curb ramp serving the baseball diamond ticket booth is inaccessible because the flared sides have slopes of 23%. AR5 30 months

2.2.

Right Side Men’s Toilet Room with Stalls at Baseball Diamonds    

2.2.a.

The toilet room sign is painted on the door and has no raised or Braille characters. TR17 24 months

2.2.b.

The door is inaccessible because knob hardware is used. D1 24 months

2.2.c.

The door is inaccessible because there is a 1½ inch high threshold. D22 30 months

2.2.d.

The route to the toilet room is inaccessible because there is a ¾ inch gap in the cement at the threshold. TR15 30 months

2.2.e.

No accessible mirror has been provided. TR14 12 months

2.2.f.

The paper towel dispenser is inaccessible because it is mounted with the controls 58 inches high. TR5 12 months

2.2.g.

The lavatory is inaccessible because the bottom of the apron is 27½ inches high. TR11 30 months

2.2.h.

The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact. TR12 24 months

2.2.i.

No accessible coat hook has been provided. TR1 12 months

2.2.j.

The side grab bar at the designated accessible toilet is inaccessible because it is mounted with the far end 50 inches from the rear wall. ST6 12 months

2.2.k.

The rear grab bar at the designated accessible toilet is inaccessible because it is mounted 10 inches from the side wall. ST4 12 months

2.3.

Right Side Women’s Toilet Room with Stalls at Baseball Diamonds    

2.3.a.

The toilet room sign is painted on the door and has no raised or Braille characters. TR17 24 months

2.3.b.

The door is inaccessible because knob hardware is used. D1 24 months

2.3.c.

The door is inaccessible because there is a 1½ inch high threshold. D22 30 months

2.3.d.

The route to the toilet room is inaccessible because there is a ¾ inch gap in the cement at the threshold. TR15 30 months

2.3.e.

No accessible mirror has been provided. TR14 12 months

2.3.f.

The paper towel dispenser is inaccessible because it is mounted with the controls 57 inches high. TR5 12 months

2.3.g.

The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact. TR12 24 months

2.3.h.

No accessible coat hook has been provided. TR1 12 months

2.3.i.

The rear grab bar at the designated accessible toilet is inaccessible because it is mounted 10 inches from the side wall. ST4 12 months

2.4.

Left Side Men’s Toilet Room with Stalls at Baseball Diamonds    

2.4.a.

The toilet room sign is painted on the door and has no raised or Braille characters. TR17 24 months

2.4.b.

The door is inaccessible because knob hardware is used. D1 24 months

2.4.c.

The door is inaccessible because there is a 1½ inch high threshold. D22 30 months

2.4.d.

The route to the toilet room is inaccessible because there is a ¾ inch gap in the cement at the threshold. TR15 30 months

2.4.e.

No accessible mirror has been provided. TR14 12 months

2.4.f.

The paper towel dispenser is inaccessible because it is mounted with the controls 57 inches high. TR5 12 months

2.4.g.

The lavatory is inaccessible because the bottom of the apron is 27½ inches high. TR11 30 months

2.4.h.

The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact. TR12 24 months

2.4.i.

The designated accessible toilet is inaccessible because its centerline is 19 inches from the side wall. ST17 30 months

2.4.j.

The designated accessible toilet is inaccessible because the flush control is on the closed side. ST2 30 months

2.4.k.

No accessible coat hook has been provided. TR1 12 months

2.5.

Left Side Women’s Toilet Room with Stalls at Baseball Diamonds    

2.5.a.

The toilet room sign is painted on the door and has no raised or Braille characters. TR17 24 months

2.5.b.

The door is inaccessible because knob hardware is used. D1 24 months

2.5.c.

The door is inaccessible because there is a 1½ inch high threshold. D22 30 months

2.5.d.

The route to the toilet room is inaccessible because there is a ¾ inch gap in the cement at the threshold. TR15 30 months

2.5.e.

No accessible mirror has been provided. TR14 12 months

2.5.f.

The paper towel dispenser is inaccessible because it is mounted with the controls 56½ inches high. TR5 12 months

2.5.g.

The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact. TR12 24 months

2.5.h.

No accessible coat hook has been provided. TR1 12 months

2.6.

Women’s Toilet Room with Stalls Near Whispering Winds Pavilion    

2.6.a.

The toilet room sign is painted on the door and has no raised or Braille characters. TR18 24 months

2.6.b.

The door is inaccessible because knob hardware is used. D1 24 months

2.6.c.

The door is inaccessible because there is a 1½ inch high threshold. D22 30 months

2.6.d.

The route to the toilet room is inaccessible because there is a ¾ inch gap in the cement at the threshold. TR15 30 months

2.6.e.

No accessible mirror has been provided. TR14 12 months

2.6.f.

The paper towel dispenser is inaccessible because it is mounted with the controls 58 inches high. TR5 12 months

2.6.g.

The lavatory is inaccessible because the bottom of the apron is 27 ½ inches high. TR11 30 months

2.6.h.

The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact. TR12 24 months

2.6.i.

The lavatory is inaccessible because it has twist-type hardware. TR10 24 months

2.6.j.

The designated accessible toilet is inaccessible because its centerline is 24 ½ inches from the side wall. ST17 30 months

2.6.k.

The designated accessible toilet is inaccessible because the flush control is on the closed side. ST2 30 months

2.6.l.

No accessible coat hook has been provided. TR1 12 months

2.6.m.

The toilet paper dispenser in the designated accessible stall is inaccessible because it is mounted on the partition in front of the toilet. ST19 12 months

2.6.n.

The side grab bar at the designated accessible toilet is inaccessible because it is mounted with the far end 49 inches from the rear wall. ST7 12 months

2.7.

Men’s Toilet Room with Stalls Near Whispering Winds Pavilion    

2.7.a.

The toilet room sign is painted on the door and has no raised or Braille characters. TR18 24 months

2.7.b.

The door is inaccessible because knob hardware is used. D1 24 months

2.7.c.

The door is inaccessible because there is a 1½ inch high threshold. D22 30 months

2.7.d.

The route to the toilet room is inaccessible because there is a ¾ inch gap in the cement at the threshold. TR15 30 months

2.7.e.

No accessible mirror has been provided. TR14 12 months

2.7.f.

The paper towel dispenser is inaccessible because it is mounted with the controls 58 inches high. TR5 12 months

2.7.g.

The lavatory is inaccessible because the bottom of the apron is 27½ inches high. TR11 30 months

2.7.h.

The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact. TR12 24 months

2.7.i.

The lavatory is inaccessible because it has twist-type hardware. TR10 24 months

2.7.j.

The designated accessible toilet is inaccessible because its centerline is 24½ inches from the side wall. ST17 30 months

2.7.k.

No accessible coat hook has been provided. TR1 12 months

2.7.l.

The toilet paper dispenser in the designated accessible stall is inaccessible because it is mounted on the partition in front of the toilet. ST19 12 months

2.7.m.

The side grab bar at the designated accessible toilet is inaccessible because it is mounted with the far end 50 inches from the rear wall. ST7 12 months

2.7.n.

The rear grab bars at the designated accessible toilet is inaccessible because it is mounted 2 inches from the wall. ST13 12 months

2.8.

Women’s Toilet Room with Stalls near Lakeview Pavilion    

2.8.a.

The toilet room sign has no raised or Braille characters. TR18 24 months

2.8.b.

The door is inaccessible because knob hardware is used. D1 24 months

2.8.c.

The pull side of the door, which is accessed through a front approach, is inaccessible because it has only 7½ inches of clear space on the latch side. D6 30 months

2.8.d.

The door is inaccessible because there is a 1½ inch high threshold. D22 30 months

2.8.e.

The route to the toilet room is inaccessible because there is a ¾ inch gap in the cement at the threshold. TR15 30 months

2.8.f.

No accessible mirror has been provided. TR14 12 months

2.8.g.

The paper towel dispenser is inaccessible because it is mounted with the controls 59 inches high. TR5 12 months

2.8.h.

The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact. TR12 24 months

2.8.i.

The lavatory is inaccessible because it has twist-type hardware. TR10 24 months

2.8.j.

The designated accessible toilet is inaccessible because its centerline is 19 inches from the side wall. ST17 30 months

2.8.k.

The designated accessible toilet is inaccessible because the flush control is on the closed side. ST2 30 months

2.8.l.

No accessible coat hook has been provided. TR1 12 months

2.8.m.

The side grab bar at the designated accessible toilet is inaccessible because it is obstructed by objects above and below it. ST8 24 months

2.8.n.

The rear grab bar at the designated accessible toilet is inaccessible because it is mounted 2 inches from the wall. ST13 12 months

2.9.

Men’s Toilet Room with Stalls near Lakeview Pavilion    

2.9.a.

The toilet room sign has no raised or Braille characters. TR18 24 months

2.9.b.

The pull side of the door, which is accessed through a front approach, is inaccessible because it has only 11½ inches of clear space on the latch side. D6 30 months

2.9.c.

The door is inaccessible because there is a 1½ inch high threshold. D22 30 months

2.9.d.

The route to the toilet room is inaccessible because there is a ¾ inch gap in the cement at the threshold. TR15 30 months

2.9.e.

No accessible mirror has been provided. TR14 12 months

2.9.f.

The paper towel dispenser is inaccessible because it is mounted with the controls 59 inches high. TR5 12 months

2.9.g.

The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact. TR12 24 months

2.9.h.

The lavatory is inaccessible because it has twist-type hardware. TR10 24 months

2.9.i.

The designated accessible toilet is inaccessible because its centerline is 19½ inches from the side wall. ST17 30 months

2.9.j.

The designated accessible toilet is inaccessible because the top of the seat is 20 inches high. ST20 30 months

2.9.k.

No accessible coat hook has been provided. TR1 12 months

2.9.l.

The toilet paper dispenser in the designated accessible stall is inaccessible because it is mounted 39½ inches from the rear wall. ST19 12 months

2.9.m.

The side grab bar at the designated accessible toilet is inaccessible because it is obstructed by the toilet paper dispenser. ST8 12 months

2.9.n.

The rear grab bar at the designated accessible toilet is inaccessible because it is mounted 2 inches from the wall. ST13 12 months

2.10.

Amenities Surrounding Lakeview Pavilion, Whispering Winds Pavilion, and Feather Landing Pavilion    

2.10.a.

The routes from the walking paths to the sand volleyball courts, the basketball courts, the gazebos, the horseshoe pits, and the playground equipment are inaccessible because they include steps and/or are over grass, which is not firm, stable, and slip resistant. AR1 30 months

2.10.b.

The route from the Lakeview Pavilion to the Whispering Winds Pavilion is inaccessible because the surface of the walking path is uneven where the walking path meets the footbridge. AR1 30 months

2.10.c.

Although two designated accessible drinking fountains are provided, there is no drinking fountain provided for people who have difficulty bending or stooping. DF3 30 months

2.10.d.

The route to the Feather Landing Pavilion is inaccessible because it has a 2 to 3 inch high change in level at the entrance to the pavilion. AR1 30 months

2.10.e.

The route from the Feather Landing Pavilion to the parking area is inaccessible because the surface of the walking path is uneven where the walking path meets the footbridge, and because the slope of the footbridge, on the side nearest the parking area, ranges between 8.8% and 10.1%, with no handrails. AR1 30 months

 