ATTACHMENT K: Program Access in Existing Facilities

The technical requirements and, where appropriate, the scoping requirements of the Standards are used as a guide for determining whether a program or activity held in an existing facility is “readily accessible to and usable by” persons with disabilities and for determining what changes are necessary to make this program or activity accessible if it continues to be provided in the existing facility in question. See 28 C.F.R. §§ 35.150(b)(1), 35.151.

The chart below lists the facilities surveyed by the Department, the access issues identified during the survey, and the actions required to correct the access issues. Required actions are listed using an alphanumeric code. The key to the alphanumeric codes is provided in Attachment M to this Agreement. In order to ensure that the programs, services, and activities housed in the County’s facilities are accessible to persons with disabilities, when viewed in their entirety, the County will take the actions referenced by the alphanumeric code within the time period specified below, which time period begins to run on the effective date of this Agreement.

Item #

Access Issue

Required Action

Completion Date

1.

Juvenile Detention Center, 401 North Main Street, Roswell

1.1.

Main Entrance

1.1.1.

The route to the entrance is not accessible because it requires traversing steps.

AR2

6 months

1.1.2.

The door is inaccessible because there is a slope of 4% within the required maneuvering clearance.

D7

6 months

1.2.

Booking and Intake Area

1.2.1.

The counter is inaccessible because it is 42 inches high.

C1

6 months

1.2.2.

The toilet room contains a number of inaccessible elements and is not accessible to people with disabilities.

TR1

6 months

1.2.3.

The shower contains a number of inaccessible elements and is not accessible to people with disabilities.

B2

6 months

1.3.

Holding Cells

1.3.1.

The toilet/lav combos throughout the Detention Center contain a number of inaccessible elements and are not accessible to people with disabilities.

TR1

18 months

1.4.

Lobby Single User Men's Toilet Room

1.4.1.

The signage provided is inaccessible because it is mounted more than 60 inches high and it does not have Braille characters.

D15

6 months

1.4.2.

The facility is inaccessible because, although the facility contains a fire alarm system, there are no visible alarms provided in the toilet room.

AL1

24 months

1.4.3.

The soap dispenser is inaccessible because it is mounted with the controls 58 inches high.

CT4

6 months

1.4.4.

The toilet is inaccessible because the centerline is 20 inches from the side wall.

TR7

24 months

1.4.5.

The toilet is inaccessible because the flush control is on the closed side.

TR4

6 months

1.4.6.

The toilet is inaccessible because there is no rear grab bar provided.

TR13

6 months

1.5.

Lobby Single User Women's Toilet Room

1.5.1.

The signage provided is inaccessible because it is mounted more than 60 inches high and it does not have Braille characters.

D15

6 months

1.5.2.

The facility is inaccessible because, although the facility contains a fire alarm system, there are no visible alarms provided in the toilet room.

AL1

24 months

1.5.3.

The soap dispenser is inaccessible because it is mounted with the controls 58 inches high.

CT4

6 months

1.5.4.

The toilet is inaccessible because the centerline is 20 inches from the side wall.

TR7

24 months

1.5.5.

The toilet is inaccessible because there is no rear grab bar provided.

TR13

6 months

2.

Chaves County Road Department, 1505 East Brasher Road, Roswell

2.1.

Parking: The parking lot has no designated accessible spaces provided.

P1

6 months

2.2.

Interior Doors: The doors throughout the building are inaccessible because the knob hardware requires tight grasping, pinching, or twisting of the wrist to operate.

D2

12 months

2.3.

Public Toilet Rooms: The toilet rooms contain a number of inaccessible elements and are not accessible to people with disabilities.

TR1

12 months

3.

Midway Joy Center, 126 Willard Road, Roswell

3.1.

Parking

3.1.1.

The parking lot is inaccessible because the gravel surface is not firm, stable, and slip resistant.

P4

30 months

3.1.2.

The parking lot is inaccessible because it has no van accessible parking space, the designated accessible parking space has no access aisle, and the vertical sign is mounted 33 inches high.

P5

30 months

3.2.

Men's Toilet Room

3.2.1.

The toilet room is inaccessible because the sign has no raised or Braille characters.

TR11

30 months

3.2.2.

The lavatory is inaccessible because the hardware requires twisting of the wrist to operate.

LS4

30 months

3.2.3.

The urinal is inaccessible because the rim is 24 1/2 inches high.

TR8

30 months

3.2.4.

The toilet room is inaccessible because there is no standard accessible toilet compartment provided.

TR2

30 months

3.3.

Women's Toilet Room

3.3.1.

The toilet room is inaccessible because the sign has no raised or Braille characters.

TR11

30 months

3.3.2.

The lavatory is inaccessible because the hardware requires twisting of the wrist to operate.

LS4

30 months

3.3.3.

The paper towel dispenser is inaccessible because it is mounted with the controls 55 inches high.

CT4

30 months

3.3.4.

The toilet room is inaccessible because there is no standard accessible toilet compartment provided.

TR2

30 months

4.

Chaves County Health Center, 200 East Chisum Street, Roswell

4.1.

Public Health Division Parking Lot

4.1.1.

The parking lot is inaccessible because the designated parking spaces lack vertical signage.

P3

12 months

4.1.2.

The parking lot is inaccessible because it has no van accessible parking space.

P5

12 months

4.2.

Public Health Division Entrance: The door is inaccessible because there is a slope of 3.3% within the required maneuvering clearance.

D7

12 months

4.3.

Interior Doors: The doors throughout the building are inaccessible because the knob hardware requires tight grasping, pinching, or twisting of the wrist to operate.

D2

12 months

4.4.

Public Health Division Lobby Men's Toilet Room

4.4.1.

No accessible mirror has been provided.

TR5

12 months

4.4.2.

The paper towel dispenser is inaccessible because it is mounted with the controls 58 inches high.

CT4

12 months

4.4.3.

The lavatory is inaccessible because the water supply and drain pipes are not insulated or otherwise configured to protect against contact.

LS2

12 months

4.5.

Public Health Division Lobby Women's Toilet Room

4.5.1.

No accessible mirror has been provided.

TR5

12 months

4.5.2.

The paper towel dispenser is inaccessible because it is mounted with the controls 59 inches high.

CT4

12 months

4.5.3.

The lavatory is inaccessible because the water supply and drain pipes are not insulated or otherwise configured to protect against contact.

LS2

12 months

4.5.4.

The toilet is inaccessible because the centerline is 23 inches from the side wall.

TR7

12 months

4.5.5.

The toilet is inaccessible because the flush control is on the closed side.

TR4

12 months

4.6.

Public Health Division Laboratory Family Toilet Room

4.6.1.

The pull side of the door is inaccessible because it has no clear space on the latch side.

D5

12 months

4.6.2.

The toilet room is inaccessible because there is insufficient turning space provided within the room.

TR21

12 months

4.6.3.

The lavatory is inaccessible because the water supply and drain pipes are not insulated or otherwise configured to protect against contact.

LS2

12 months

4.6.4.

No accessible mirror has been provided.

TR5

12 months

4.6.5.

The lavatory is inaccessible because the bottom of the lavatory apron is 24 1/2 inches high.

LS3

12 months

4.6.6.

The toilet paper dispenser is inaccessible because it is mounted more than 9 inches from the front of the toilet.

TR6

12 months

4.6.7.

The toilet is inaccessible because there are no grab bars provided.

TR18

12 months

4.7.

Public Health Division Drinking Fountain

4.7.1.

The drinking fountain is inaccessible because the clear floor space is less than 30 inches wide and is obstructed by the open door.

DF4

12 months

4.7.2.

Although a designated accessible drinking fountain is provided, there is no drinking fountain provided for people who have difficulty bending or stooping.

DF3

12 months

4.8.

Public Health Division Exam Rooms and Offices: The signage provided is inaccessible because it is mounted above the doors and it does not have raised and Braille characters.

D15

12 months

4.9.

W.I.C. Nutrition Program Parking

4.9.1.

The parking lot is inaccessible because it has no van accessible parking space.

P5

12 months

4.9.2.

The designated accessible parking spaces are inaccessible because they lack vertical signs.

P3

12 months

4.9.3.

The designated accessible parking spaces are inaccessible because the curb ramp is located in the access aisle.

P2

12 months

4.10.

W.I.C. Nutrition Program Entrance

4.10.1.

The pull side of the door is inaccessible because it has only 7 inches of clear space on the latch side.

D5

12 months

4.10.2.

The door is inaccessible because there is a slope of 8.2% within the required maneuvering clearance.

D7

12 months

4.11.

W.I.C. Nutrition Program Men's Toilet Room

4.11.1.

The pull side of the door is inaccessible because it has less than 18 inches of clear space on the latch side.

D5

12 months

4.11.2.

No accessible mirror has been provided.

TR5

12 months

4.11.3.

The soap dispenser is inaccessible because it is mounted with the controls 52 inches high with only a forward reach provided.

CT4

12 months

4.11.4.

The toilet is inaccessible because the flush control is on the closed side.

TR4

12 months

4.12.

W.I.C. Nutrition Program Women's Toilet Room

4.12.1.

The door is inaccessible because it requires 13 pounds of force to open.

D3

12 months

4.12.2.

The paper towel dispenser is inaccessible because it is mounted with the controls 56 inches high.

CT4

12 months

4.12.3.

The coat hook is inaccessible because it is mounted 63 inches high.

TR3

12 months

4.13.

W.I.C. Nutrition Program Drinking Fountain: Although a designated accessible drinking fountain is provided, there is no drinking fountain provided for people who have difficulty bending or stooping.

DF3

12 months

4.14.

Cooperative Extension Service and Children's Medical Service Parking Lot

4.14.1.

The parking lot is inaccessible because it has no van accessible parking space.

P5

12 months

4.14.2.

The designated accessible parking spaces are inaccessible because they lack vertical signs.

P3

12 months

4.14.3.

Two of the designated accessible parking spaces are inaccessible because the curb ramp is located in the access aisle.

P2

12 months

4.14.4.

The curb ramp is inaccessible because it has a slope of 10.7%.

AR4

12 months

4.15.

Children's Medical Service Entrance

4.15.1.

The pull side of the door is inaccessible because it has only 6 inches of clear space on the latch side.

D5

12 months

4.15.2.

The door is inaccessible because there is a slope of 8.8% within the required maneuvering clearance.

D7

12 months

4.16.

Cooperative Extension Service Entrance

4.16.1.

The pull side of the door is inaccessible because it has only 6 inches of clear space on the latch side.

D5

12 months

4.16.2.

The door is inaccessible because there is a slope of 9.4% within the required maneuvering clearance.

D7

12 months

4.17.

Cooperative Extension Auditorium

4.17.1.

The parking lot, with a total of 29 parking spaces, is inaccessible because it has only 1 designated accessible space provided, there is no designated van accessible space, there is no vertical signage, and the access aisle is obstructed by the curb ramp. This lot requires 1 van accessible space and 1 standard accessible space.

P1

12 months

4.17.2.

The entrance door is inaccessible because there is a slope of 8% within the required maneuvering clearance.

D7

12 months

4.17.3.

The interior signage is inaccessible because it is mounted above the doors and it does not have raised and Braille characters.

D15

12 months

5.

Tres Amigo Medical Complex, 1600 Southeast Main Street, Roswell

5.1.

Parking: The designated accessible parking spaces are inaccessible because the curb ramps are located in the access aisles.

P2

12 months

5.2.

Suites B and C, New Mexico Senior Olympics, Main Entrance: The door is inaccessible because there is a slope of 8.5% within the required maneuvering clearance.

D7

12 months

5.3.

Suites B and C, New Mexico Senior Olympics, Unisex Toilet Room

5.3.1.

No accessible mirror has been provided.

TR5

12 months

5.3.2.

The lavatory is inaccessible because the water supply and drain pipes are not insulated or otherwise configured to protect against contact.

LS2

12 months

5.4.

Suite D, Southwestern New Mexico Economic Development District, Entrance

5.4.1.

The vestibule between the doors is inaccessible because it is not sufficiently deep.

D4

12 months

5.4.2.

The interior door of the vestibule is inaccessible because it requires 10 pounds of force to open.

D3

12 months

5.5.

Suite E, Jack L. Graham MD PA Dermatology, Entrance

5.5.1.

The exterior door is inaccessible because there is a slope of more than 2.08% within the required maneuvering clearance.

D7

12 months

5.5.2.

The vestibule between the doors is inaccessible because it is not sufficiently deep.

D4

12 months

5.6.

Suite E, Jack L. Graham MD PA Dermatology, Offices: The interior doors are inaccessible because the knob hardware requires tight grasping, pinching, or twisting of the wrist to operate.

D2

12 months

5.7.

Suite F, Surgery

5.7.1.

The exterior door is inaccessible because there is a slope of more than 2.08% within the required maneuvering clearance.

D7

12 months

5.7.2.

The vestibule between the doors is inaccessible because it is not sufficiently deep.

D4

12 months

6.

Pecos Valley Medical Complex, 1606 Southeast Main Street, Roswell

6.1.

Parking

6.1.1.

The designated accessible parking spaces are inaccessible because they lack vertical signage.

P3

12 months

6.1.2.

The parking lot is inaccessible because it has no designated van accessible parking space.

P5

12 months

6.1.3.

The designated accessible parking spaces are inaccessible because the curb ramps are located in the access aisles.

P2

12 months

6.1.4.

The curb ramps are inaccessible because they have slopes of between 9.4% and 10.2%.

AR4