ATTACHMENT I: Modifications to Newly Constructed Facilities

The chart below lists the facilities surveyed by the Department, the access issues identified during the survey, and the actions required to correct the access issues. Required actions are listed using an alphanumeric code. The key to the alphanumeric codes is provided in Attachment M to this Agreement. In order to ensure that the following spaces and elements in County facilities for which construction was commenced after January 26, 1992, are readily accessible to and usable by persons with disabilities, the County will take the actions referenced by the alphanumeric code within the time periods specified below, which time periods will begin to run on the effective date of this Agreement.

Item #

Access Issue

Required Action

Completion Date

1.

Administration Building, 1 Saint Mary’s Place, Roswell

1.1.

Parking

1.1.1.

The parking lots are inaccessible because the van accessible parking spaces have access aisles that are less than 90 inches wide and that contain curb ramps.

P5

6 months

1.1.2.

The curb ramp leading from the south side parking area to the main entrance is inaccessible because it has a slope of 12.3%.

AR4

6 months

1.1.3.

The Sheriff’s Office employee parking lot is inaccessible because it has no van accessible parking space.

P5

6 months

1.2.

Sheriff’s Office Lobby Single User Men’s Toilet Room: The door is inaccessible because it requires 20 pounds of force to open.

D3

6 months

1.3.

Sheriff’s Office Lobby Single User Women’s Toilet Room

1.3.1.

The door is inaccessible because it requires 20 pounds of force to open.

D3

6 months

1.3.2.

The toilet is inaccessible because the flush control is on the closed side.

TR4

6 months

1.4.

Sheriff’s Office Pecos Valley Regional/Communication Center Single User Toilet Room: The toilet room is inaccessible because the sign is mounted on the hinge side of the door.

TR11

6 months

1.5.

Sheriff’s Office Booking Men’s Toilet Room

1.5.1.

The door is inaccessible because it requires 8 pounds of force to open.

D3

6 months

1.5.2.

The toilet is inaccessible because the flush control is on the closed side.

TR4

6 months

1.6.

Sheriff’s Office Interior Route: The area between locker rooms 202 and 204 is inaccessible because the first aid box protrudes into the walkway and is not detectable to blind persons using a cane.

AR7

6 months

1.7.

Sheriff’s Office Men’s Locker Room 202

1.7.1.

The bench is inaccessible because it is 9_ inches deep.

LR2

6 months

1.7.2.

The locker room is inaccessible because the drinking fountain protrudes into the walkway and is not detectable to blind persons using a cane.

AR7

6 months

1.8.

Sheriff’s Office Women’s Locker Room 204: The bench is inaccessible because it is 9 1/2 inches deep, and it does not provide clear floor space alongside to allow a transfer.

LR2

6 months

1.9.

Sheriff’s Office Booking Area: There is no accessible sink provided.

LS1

6 months

1.10.

Sheriff’s Office Booking Area Holding Cell: There is no accessible cell provided.

PJ1

6 months

1.11.

Sheriff’s Office Gym

1.11.1.

The route from the entrance to the equipment is inaccessible because it contains a 3/4 inch high step onto the mat.

AR2

6 months

1.11.2.

The drinking fountain is inaccessible because it lacks clear floor space.

DF4

6 months

1.12.

Sheriff’s Office Break Room

1.12.1.

The microwave is inaccessible because it is mounted with the controls 63 inches high.

CT4

6 months

1.12.2.

The paper towel dispenser is inaccessible because it is mounted with the controls 53 inches high with only a forward reach provided.

CT4

6 months

1.13.

Sheriff’s Office Training Room: There is no accessible route directly connecting the floor to the stage.

AA1

12 months

1.14.

Treasurer Office Unisex Toilet Room: The toilet is inaccessible because the flush control is on the closed side.

TR4

6 months

1.15.

Treasurer Office Break Room: The microwave is inaccessible because it is mounted with the controls 63 inches high.

CT4

6 months

1.16.

County Manager’s Office Women’s Single User Toilet Room: The toilet is inaccessible because the flush control is on the closed side.

TR4

6 months

1.17.

County Manager’s Office Break Room

1.17.1.

The microwave is inaccessible because it is mounted with the controls 65 inches high.

CT4

6 months

1.17.2.

The paper towel dispenser is inaccessible because it is mounted with the controls 59 inches high.

CT4

6 months

1.18.

Planning and Zoning Break Room: The microwave is inaccessible because it is mounted with the controls 62 inches high.

CT4

6 months

1.19.

Lobby Toilet Rooms

1.19.1.

The toilet compartments are inaccessible because the compartment doors are located directly in front of the toilets.

TR23

6 months

1.19.2.

This area is inaccessible because the drinking fountain protrudes into the walkway and is not detectable to blind persons using a cane.

AR7

6 months

1.20.

Data Processing Unisex Toilet Room: The toilet is inaccessible because the flush control is on the closed side.

TR4

6 months

1.21.

Finance Department Break Room: The microwave is inaccessible because it is mounted with the controls 61 inches high.

CT4

6 months

1.22.

County Assessor’s Office Women’s Toilet Room: The toilet is inaccessible because the flush control is on the closed side.

TR4

6 months

1.23.

County Clerk’s Office Women’s Toilet Room: The toilet is inaccessible because the flush control is on the closed side.

TR4

6 months

1.24.

Area “D” Storage Room: The door is inaccessible because the knob hardware requires tight grasping, pinching, or twisting of the wrist to operate.

D2

6 months

2.

La Casa Community Health Center, 1511 South Grand Avenue, Roswell

2.1.

Parking: The parking lot, with a total of 54 parking spaces, is inaccessible because it has only 2 designated accessible spaces provided, there is no designated van accessible space, one of the designated accessible spaces lacks a vertical sign, and the existing sign is mounted too low. This lot requires 1 van accessible space and 2 standard accessible spaces.

P1

6 months

2.2.

Interior Doors: The doors throughout the building are inaccessible because the knob hardware requires tight grasping, pinching, or twisting of the wrist to operate.

D2

6 months

2.3.

Lobby Unisex Toilet Room

2.3.1.

The door is inaccessible because it requires 12 pounds of force to open.

D3

6 months

2.3.2.

The paper towel dispenser is inaccessible because it is mounted with the controls 53 inches high with only a forward reach provided.

CT4

6 months

2.3.3.

The lavatory is inaccessible because the water supply and drain pipes are not insulated or otherwise configured to protect against contact.

LS2

6 months

2.3.4.

The toilet is inaccessible because the rear grab bar is 24 inches long.

TR14

6 months

2.4.

Exam Rooms

2.4.1.

The lavatories are inaccessible because the water supply and drain pipes are not insulated or otherwise configured to protect against contact.

LS2

6 months

2.4.2.

The exam rooms are inaccessible because the paper towel dispensers and door baskets protrude into the walkway and are not detectable to blind persons using a cane.

AR7

6 months

2.4.3.

The pull sides of the doors are inaccessible because the clearance is obstructed by the lavatories.

D5

6 months

2.5.

Family Toilet Room by Exam Room #6

2.5.1.

The door is inaccessible because it requires 10 pounds of force to open.

D3

6 months

2.5.2.

The toilet is inaccessible because the flush control is on the closed side.

TR4

6 months

2.5.3.

The toilet is inaccessible because the clear floor space is obstructed by furniture.

TR24

6 months

2.6.

Route by Exam Room #6: This area is inaccessible because the defibrillator protrudes into the walkway and is not detectable to blind persons using a cane.

AR7

6 months

3.

Counseling Associates Building, 1010 South Garden Avenue, Roswell

3.1.

Front Parking Lot

3.1.1.

The designated accessible parking space is inaccessible because the curb ramp is located in the access aisle.

P2

24 months

3.1.2.

The built-up curb ramp is inaccessible because it has a slope of 11.4%.

AR4

24 months

3.1.3.

The parking lot is inaccessible because it has no van accessible parking space.

P5

24 months

3.2.

Rear Parking Lot

3.2.1.

The designated accessible parking space is inaccessible because the curb ramp is located in the access aisle.

P2

24 months

3.2.2.

The built-up curb ramp is inaccessible because it has a slope of 11.8%.

AR4

24 months

3.2.3.

The parking lot is inaccessible because it has no van accessible parking space.

P5

24 months

3.3.

Women’s Toilet Room by Multi-Purpose Area

3.3.1.

No accessible mirror has been provided.

TR5

24 months

3.3.2.

The coat hook is inaccessible because it is mounted 60 inches high.

TR3

24 months

3.3.3.

This area is inaccessible because the feminine products dispenser protrudes into the walkway and is not detectable to blind persons using a cane.

AR7

24 months

3.4.

Men’s Toilet Room by Multi-Purpose Area

3.4.1.

No accessible mirror has been provided.

TR5

24 months

3.4.2.

The coat hook is inaccessible because it is mounted 60 inches high.

TR3

24 months

3.4.3.

The toilet is inaccessible because the flush control is on the closed side.

TR4

24 months

3.5.

Unisex Toilet Room with Shower

3.5.1.

The toilet is inaccessible because there is no side grab bar provided.

TR16

24 months

3.5.2.

The shower is inaccessible because there is no maneuvering clearance provided beyond the seat wall.

B2

24 months

3.6.

Drinking Fountain: This area is inaccessible because the drinking fountain protrudes into the walkway and is not detectable to blind persons using a cane.

AR7

24 months

3.7.

Kitchen

3.7.1.

The sink is inaccessible because it provides no knee clearance.

LS3

24 months

3.7.2.

The sink is inaccessible because the hardware requires twisting of the wrist to operate.

LS4

24 months

4.

Chaves County Joy Center, 1822 North Montana, Roswell

4.1.

Main Parking Lot

4.1.1.

The parking lot is inaccessible because it has no van accessible parking space.

P5

24 months

4.1.2.

The designated accessible parking spaces are inaccessible because the vertical signs are mounted too low.

P3

24 months

4.1.3.

Six of the designated accessible parking spaces are inaccessible because the curb ramps are located in the access aisles.

P2

24 months

4.2.

Employee Area Family Toilet Room

4.2.1.

No accessible mirror has been provided.

TR5

24 months

4.2.2.

The lavatory is inaccessible because the water supply and drain pipes are not insulated or otherwise configured to protect against contact.

LS2

24 months

4.2.3.

The toilet is inaccessible because the flush control is on the closed side.

TR4

24 months

4.2.4.

The toilet paper dispenser is inaccessible because it is mounted more than 9 inches from the front of the toilet.

TR6

24 months

4.3.

Dining Area

4.3.1.

The assembly area is inaccessible because there is no assistive listening system provided.

AA4

24 months

4.3.2.

The coat rack is inaccessible because it is mounted 71 inches high.

CT4

24 months

4.4.

Women's Toilet Room by Dining Area

4.4.1.

The door is inaccessible because it requires 6 pounds of force to open.

D3

24 months

4.4.2.

The coat hook is inaccessible because it is mounted 59 inches high.

TR3

24 months

4.4.3.

The toilet paper dispenser is inaccessible because it is mounted 17 inches from the front of the toilet.

TR6

24 months

4.4.4.

The toilet room is inaccessible because, although there are more than 6 stalls provided, there is no ambulatory stall provided.

TR22

24 months

4.5.

Men's Toilet Room by Dining Area

4.5.1.

The door is inaccessible because it requires 10 pounds of force to open.

D3

6 months

4.5.2.

The coat hook is inaccessible because it is mounted 59 inches high.

TR3

24 months

4.6.

Employee Area Kitchen

4.6.1.

The sinks are inaccessible because the tops of the counters are 36 inches and 37 inches high and the bottoms of the aprons are 25 inches and 23 1/2 inches high.

LS3

24 months

4.6.2.

The employee lavatory is inaccessible because the water supply and drain pipes are not insulated or otherwise configured to protect against contact.

LS2

24 months

4.7.

Employee Kitchen Unisex Toilet Room: The toilet is inaccessible because the flush control is on the closed side.

TR4

24 months

4.8.

Women's Toilet Room by Adult Day Care

4.8.1.

The signage is inaccessible because it is mounted 45 inches high to the bottom.

D15

24 months

4.8.2.

The door is inaccessible because it requires 10 pounds of force to open.

D3

24 months

4.9.

Men's Toilet Room by Adult Day Care

4.9.1.

The signage provided is inaccessible because it is mounted 46 inches high to the bottom.

D15

24 months

4.9.2.

The door is inaccessible because it requires 10 pounds of force to open.

D3

24 months

4.10.

Outdoor Storage Area

4.10.1.

The door is inaccessible because the knob hardware requires tight grasping, pinching, or twisting of the wrist to operate.

D2

24 months

4.10.2.

The door is inaccessible because there is a slope of 6.1% within the required maneuvering clearance.

D7

24 months

5.

Chaves County Detention Center, 3701 South Atkinson, Roswell

5.1.

Parking Lot: Two of the designated accessible parking spaces are inaccessible because they have no access aisles.

P2

12 months

5.2.

Lobby Men's Toilet Room

5.2.1.

The signage provided is inaccessible because it is mounted on the pull side of the door.

D15

12 months

5.2.2.

The facility is inaccessible because, although the facility contains a fire alarm system, there are no visible alarms provided in the toilet room.

AL1

12 months

5.2.3.

The paper towel dispenser is inaccessible because the controls require tight grasping or pinching to operate.

CT2

12 months

5.2.4.

The toilet paper dispenser is inaccessible because it is mounted more than 9 inches from the front of the toilet.

TR6

12 months

5.2.5.

The toilet is inaccessible because the flush control is on the closed side.

TR4

12 months

5.2.6.

The toilet is inaccessible because the grab bars are mounted 42 inches high.

TR19

12 months

5.2.7.

The toilet is inaccessible because the centerline is 19 inches from the side wall.

TR7

12 months

5.3.

Lobby Women's Toilet Room

5.3.1.

The signage provided is inaccessible because it is mounted on the pull side of the door.

D15

12 months

5.3.2.

The facility is inaccessible because, although the facility contains a fire alarm system, there are no visible alarms provided in the toilet room.

AL1

12 months

5.3.3.

The paper towel dispenser is inaccessible because the controls require tight grasping or pinching to operate.

CT2

12 months

5.3.4.

The sanitary napkin dispenser is inaccessible because the controls require twisting of the wrist to operate.

CT2

12 months

5.3.5.

The toilet room is inaccessible because the sanitary napkin dispenser protrudes into the walkway and is not detectable to blind persons using a cane.

AR7

12 months

5.3.6.

The toilet paper dispenser is inaccessible because it is mounted more than 9 inches from the front of the toilet.

TR6

12 months

5.3.7.

The toilet is inaccessible because the centerline is 19 inches from the side wall.

TR7

12 months

5.3.8.

The coat hook is inaccessible because it is mounted 66 inches high.

TR3

12 months

5.3.9.

The toilet is inaccessible because the grab bars are mounted 42 inches high.

TR19

12 months

5.4.

Administration Hallway Employee Women's Toilet Room

5.4.1.

The signage provided is inaccessible because it is mounted on the pull side of the door.

D15

12 months

5.4.2.

The facility is inaccessible because, although the facility contains a fire alarm system, there are no visible alarms provided in the toilet room.

AL1

12 months

5.4.3.

The paper towel dispenser is inaccessible because it is mounted with the controls 60 inches high.

CT4

12 months

5.4.4.

The toilet is inaccessible because the clear floor space is obstructed by furniture.

TR24

12 months

5.4.5.

The toilet is inaccessible because the flush control is on the closed side.

TR4

12 months

5.4.6.

The toilet paper dispenser is inaccessible because it is mounted more than 9 inches from the front of the toilet.

TR6

12 months

5.4.7.

The toilet is inaccessible because the grab bars are mounted 42 inches high.

TR19

12 months

5.5.

Women's Locker Room

5.5.1.

The toilet compartment is inaccessible because the compartment door is located directly in front of the toilet.

TR23

12 months

5.5.2.

The soap dispenser is inaccessible because it is mounted 54 inches high over the counter.

CT3

12 months

5.5.3.

The paper towel dispenser is inaccessible because it is mounted 67 inches high.

CT4

12 months

5.5.4.

The toilet is inaccessible because the flush control is on the closed side.

TR4

12 months

5.5.5.

The toilet paper dispenser is inaccessible because it is mounted more than 9 inches from the front of the toilet.

TR6

12 months

5.5.6.

The toilet is inaccessible because the grab bars are mounted 42 inches high.

TR19

12 months

5.5.7.

There is no accessible locker provided.

LR3

6 months

5.6.

Administration Hallway Employee Men's Toilet Room

5.6.1.

The signage provided is inaccessible because it is mounted on the pull side of the door.

D15

12 months

5.6.2.

The facility is inaccessible because, although the facility contains a fire alarm system, there are no visible alarms provided in the toilet room.

AL1

12 months

5.6.3.

The paper towel dispenser is inaccessible because it is mounted with the controls 60 inches high.

CT4

12 months

5.6.4.

The soap dispenser is inaccessible because it is mounted with the controls 52 inches high with only a forward reach provided.

CT4

12 months

5.6.5.

The toilet paper dispenser is inaccessible because it is mounted more than 9 inches from the front of the toilet.

TR6

12 months

5.6.6.

The toilet is inaccessible because the grab bars are mounted 42 inches high.

TR19

12 months

5.7.

Men's Locker Room

5.7.1.

The toilet compartment is inaccessible because the compartment door is located directly in front of the toilet.

TR23

12 months

5.7.2.

The toilet paper dispenser is inaccessible because it is mounted more than 9 inches from the front of the toilet.

TR6

12 months

5.7.3.

There is no accessible locker provided.

LR3

12 months

5.7.4.

The coat hook is inaccessible because it is mounted 66 inches high.

TR3

12 months

5.7.5.

The soap dispenser is inaccessible because it is mounted with the controls 56 inches high.

CT4

12 months

5.7.6.

The toilet is inaccessible because the grab bars are mounted 42 inches high.

TR19

12 months

5.8.

Main Hallway Employee Women's Toilet Room

5.8.1.

The signage provided is inaccessible because it is mounted on the pull side of the door.

D15

12 months

5.8.2.

The facility is inaccessible because, although the facility contains a fire alarm system, there are no visible alarms provided in the toilet room.

AL1

12 months

5.8.3.

The lavatory is inaccessible because the water supply and drain pipes are not insulated or otherwise configured to protect against contact.

LS2

12 months

5.8.4.

The paper towel dispenser is inaccessible because it is mounted with the controls 58 inches high.

CT4

12 months

5.8.5.

The toilet is inaccessible because the flush control is on the closed side.

TR4

12 months

5.8.6.

The toilet paper dispenser is inaccessible because it is mounted more than 9 inches from the front of the toilet.

TR6

12 months

5.8.7.

The toilet is inaccessible because there are no grab bars provided.

TR18

12 months

5.9.

Main Hallway Employee Men's Toilet Room

5.9.1.

The signage provided is inaccessible because it is mounted on the pull side of the door.

D15

12 months

5.9.2.

The facility is inaccessible because, although the facility contains a fire alarm system, there are no visible alarms provided in the toilet room.

AL1

12 months

5.9.3.

The lavatory is inaccessible because the water supply and drain pipes are not insulated or otherwise configured to protect against contact.

LS2

12 months

5.9.4.

The paper towel dispenser is inaccessible because it is mounted with the controls 58 inches high.

CT4

12 months

5.9.5.

The toilet paper dispenser is inaccessible because it is mounted more than 9 inches from the front of the toilet.

TR6

12 months

5.9.6.

The toilet is inaccessible because there are no grab bars provided.

TR18

12 months

5.10.

Dorms: The signage provided is inaccessible because it does not have raised and Braille characters.

D15

12 months

5.11.

Road Crew Dorm Toilet Room

5.11.1.

The lavatory is inaccessible because the hardware requires twisting of the wrist to operate.

LS4

12 months

5.11.2.

The toilet is inaccessible because the flush control is on the closed side.

TR4

12 months

5.11.3.

The toilet is inaccessible because the grab bars are mounted 42 inches high.

TR19

12 months

5.11.4.

The shower contains a number of inaccessible elements and is not accessible to people with disabilities.

B2

12 months

5.12.

In House Workers Dorm #1

5.12.1.

The lavatory is inaccessible because the water supply and drain pipes are not insulated or otherwise configured to protect against contact.

LS2

12 months

5.12.2.

The toilet is inaccessible because there are no grab bars provided.

TR18

12 months

5.12.3.

The toilet is inaccessible because the flush control is on the closed side.

TR4

12 months

5.12.4.

The shower contains a number of inaccessible elements and is not accessible to people with disabilities.

B2

12 months

5.13.

In House Workers Dorm #2

5.13.1.

The dorm room is inaccessible because the television shelf protrudes into the walkway and is not detectable to blind persons using a cane.

AR7

12 months

5.13.2.

The lavatory is inaccessible because the hardware requires twisting of the wrist to operate.

LS4

12 months

5.13.3.

No accessible mirror has been provided.

TR5

12 months

5.13.4.

The toilet is inaccessible because the grab bars are mounted 42 inches high.

TR19

12 months

5.13.5.

The shower contains a number of inaccessible elements and is not accessible to people with disabilities.

B2

12 months

5.14.

Clothing Exchange Shower: The shower contains a number of inaccessible elements and is not accessible to people with disabilities.

B2

12 months

5.15.

Booking Area Holding Cells with Toilets: The toilets are inaccessible because there are no grab bars provided.

TR18

12 months

5.16.

Designated Accessible Medical Holding Cell: The toilet is inaccessible because there are no grab bars provided.

TR18

12 months

5.17.

South D Segregation Unit Holding Cell #8: The toilet is inaccessible because there are no grab bars provided.

TR18

12 months

5.18.

Kitchen Hallway Inmate Toilet Room: The toilet room contains a number of inaccessible elements and is not accessible to people with disabilities.

TR1

12 months

5.19.

Court Holding Cells: The toilet room contains a number of inaccessible elements and is not accessible to people with disabilities.

TR1

12 months

5.20.

Kitchen Hallway Employee Toilet Room

5.20.1.

The toilet is inaccessible because there are no grab bars provided.

TR18

12 months

5.20.2.

The toilet is inaccessible because the top of the seat is 15 inches high.

TR9

12 months

5.20.3.

The lavatory is inaccessible because the water supply and drain pipes are not insulated or otherwise configured to protect against contact.

LS2

12 months

5.20.4.

The toilet is inaccessible because the flush control is on the closed side.

TR4

12 months

5.20.5.

The paper towel dispenser is inaccessible because it is mounted behind the toilet with the controls 50 inches high.

CT3

12 months

5.20.6.

The toilet room is inaccessible because there is insufficient turning space provided within the room.

TR21

12 months

5.21.

Northeast Maximum Security

5.21.1.

The shower contains a number of inaccessible elements and is not accessible to people with disabilities.

B2

12 months

5.21.2.

The toilet is inaccessible because the centerline is 20 inches from the side wall.

TR7

12 months

5.21.3.

The toilet is inaccessible because there is no rear grab bar provided.

TR13

12 months

5.22.

South F Maximum Security, SA, SB, and SC Dorms, NB, NC and ND Cells

5.22.1.

There are no accessible cells provided.

PJ1

12 months

5.22.2.

There are no accessible tables provided.

DW1

12 months

5.22.3.

There are no accessible showers provided.

B2

12 months

5.22.4.

The water closet and lavatory combination fixtures in the group toilet rooms contain a number of inaccessible elements and are not accessible to people with disabilities.

TR1

12 months

 

Project Civic Access | archive.ADA.gov Home Page