Precinct # |
Ward |
Name of Polling Place |
Address |
City |
Space / Element Name |
Subject / Issue |
|
|
Description of Issue / 2010 ADA Requirement |
§§ 2010 |
---|---|---|---|---|---|---|---|---|---|---|
103 |
Verona |
Augusta County Government Center |
18 Government Center Lane |
Verona |
Sidewalk & Walkways |
cross slope: side at parking |
exceeds 1:48 |
4.3.7 |
The cross slope of walking surfaces shall not be steeper than 1:48. |
403.3, |
103 |
Verona |
Augusta County Government Center |
18 Government Center Lane |
Verona |
Ramp |
cross slope: side ramp |
exceeds 1:48 |
4.8.6 |
Cross slope of ramp runs shall not be steeper than 1:48. |
405.3 |
103 |
Verona |
Augusta County Government Center |
18 Government Center Lane |
Verona |
Ramp |
slope: side ramp |
exceeds 1:12 |
4.8.2 |
Ramp runs shall have a running slope not steeper than 1:12. |
405.2 |
103 |
Verona |
Augusta County Government Center |
18 Government Center Lane |
Verona |
Building Entrance |
level landing: top of side ramp |
maneuvering clearance |
4.13.6, Fig.25 |
The landing clear length shall be 60 inches long minimum. |
404.2.4, 404.2.4.1, Table 404.2.4.1, Figure 404.2.4.1(a), 405.7, 405.7.3 |
103 |
Verona |
Augusta County Government Center |
18 Government Center Lane |
Verona |
Sidewalk & Walkways |
cross slope: front at main entrance |
exceeds 1:48 |
4.3.7 |
The cross slope of walking surfaces shall not be steeper than 1:48. |
403.3, |
103 |
Verona |
Augusta County Government Center |
18 Government Center Lane |
Verona |
Ramp |
slope: front ramp right |
exceeds 1:12 |
4.8.2 |
Ramp runs shall have a running slope not steeper than 1:12. |
405.2 |
103 |
Verona |
Augusta County Government Center |
18 Government Center Lane |
Verona |
Ramp |
slope: front ramp left |
exceeds 1:12 |
4.8.2 |
Ramp runs shall have a running slope not steeper than 1:12. |
405.2 |
103 |
Verona |
Augusta County Government Center |
18 Government Center Lane |
Verona |
Ramp |
landing: midway right |
insufficient length |
4.8.4(2) |
The landing clear length shall be 60 inches long minimum. |
405.7, 405.7.3 |
103 |
Verona |
Augusta County Government Center |
18 Government Center Lane |
Verona |
Ramp |
landing: midway left |
insufficient length |
4.8.4(2) |
The landing clear length shall be 60 inches long minimum. |
405.7, 405.7.3 |
103 |
Verona |
Augusta County Government Center |
18 Government Center Lane |
Verona |
Ramp |
handrails: front ramp right |
handrails segments omitted |
4.8.5, 4.8.5.1, 4.9.4.(2) |
Handrails shall be provided on both sides of ramps. Handrail gripping surfaces shall extend beyond and in the same direction of ramp runs. |
505.1. 505.2, 505.10 |
103 |
Verona |
Augusta County Government Center |
18 Government Center Lane |
Verona |
Ramp |
handrails: front ramp left |
handrails segments omitted |
4.8.5, 4.8.5.1, 4.9.4.(2) |
Handrails shall be provided on both sides of ramps. Handrail gripping surfaces shall extend beyond and in the same direction of ramp runs. |
505.1. 505.2, 505.10 |
201 |
Crimora |
Crimora United Methodist Church |
1691 New Hope & Crimora Rd |
Crimora |
Parking |
slope |
exceeds 1:48 |
4.6.3 |
For parking spaces and access aisle, changes in level are not permitted. |
502.4, 502.4 EX |
201 |
Crimora |
Crimora United Methodist Church |
1691 New Hope & Crimora Rd |
Crimora |
Sidewalk & Walkways |
slope: at parking |
exceeds 1:20 |
4.3.7, 4.3.8, 4.7.2 |
Changes in level greater than ½ inch high shall be ramped. |
303.4, 405.2 |
201 |
Crimora |
Crimora United Methodist Church |
1691 New Hope & Crimora Rd |
Crimora |
Sidewalk & Walkways |
slope: at ramp |
exceeds 1:12 |
4.8.2 |
Ramp runs shall have a running slope not steeper than 1:12. |
405.2 |
201 |
Crimora |
Crimora United Methodist Church |
1691 New Hope & Crimora Rd |
Crimora |
Ramp |
landings |
insufficient length |
4.8.4(2) |
The landing clear length shall be 60 inches long minimum. |
405.7, 405.7.3 |
201 |
Crimora |
Crimora United Methodist Church |
1691 New Hope & Crimora Rd |
Crimora |
Ramp |
handrails |
handrails omitted |
4.8.5, 4.8.5.1, 4.9.4.(2) |
Handrails shall be provided on both sides of ramps. Handrail gripping surfaces shall extend beyond and in the same direction of ramp runs. |
505.1. 505.2, 505.10 |