ATTACHMENT K: Program Access in Existing Facilities

Please Note: Paragraph 42 of the Agreement requires that within three months of the effective date of this Agreement, the City will provide signage as necessary to comply with 28 C.F.R. § 35.163(b), after having surveyed all facilities that are the subject of this Agreement for the purpose of identifying those that have multiple entrances not all of which are accessible.

The technical requirements and, where appropriate, the scoping requirements of the Standards are used as a guide for determining whether a program or activity held in an existing facility is “readily accessible to and usable by” persons with disabilities and for determining what changes are necessary to make this program or activity accessible if it continues to be provided in the existing facility in question.  See 28 C.F.R. §§ 35.150(b)(1), 35.151.

In order to ensure that each of the City’s programs, services, and activities operating at a facility that is the subject of this Agreement, when viewed in its entirety, is readily accessible to and usable by persons with mobility impairments, the City will take the actions referenced by the alphanumeric code and described in detail in Attachment M to this Settlement Agreement. Actions are to be completed before the end of the time specified in the Completion Date column.

Item #

Access Issue

 

Required Action

Completion Date

1 

CITY HALL SOUTH, located at 55 Trinity Avenue

   

1.1

Interior Signage.  Much of the signage provided is inaccessible because it does not have raised or Braille characters.

D26

24 months

1.2

Interior Doors.  Many of the interior doors are inaccessible because they require more than 5 pounds of force to open.

D2

12 months

1.3

Assistive Listening Systems.  There are a number of conference rooms, council chambers, committee rooms, etc., but there are no assistive listening systems provided.

AA5

30 months

1.4

Women’s Toilet Rooms with Stalls: Ground Floor

   

1.4.a 

The toilet room sign lacks the International Symbol of Accessibility and does not have raised or Braille characters.

TR17

24 months

1.4.b 

The seat cover dispenser is inaccessible because it is mounted 64 inches high.

TR5

12 months

1.4.c 

The paper towel dispenser protrudes into the walkway and is not detectable to blind persons using a cane.

AR8

12 months

1.4.d 

The lavatory is inaccessible because the rim or counter is 27 inches high to the bottom.

TR11

24 months

1.4.e 

The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact.

TR12

24 months

1.4.f

The designated accessible stall is incorrectly configured as an ambulatory stall, and there is no standard accessible stall provided.

ST15

30 months

1.5

Men’s Toilet Rooms with Stalls: Ground Floor

   

1.5.a 

The toilet room sign lacks the International Symbol of Accessibility and does not have raised or Braille characters.

TR17

24 months

1.5.b 

The seat cover dispenser is inaccessible because it is mounted 60 inches high.

TR5

12 months

1.5.c 

The paper towel dispenser protrudes into the walkway and is not detectable to blind persons using a cane.

AR8

12 months

1.5.d 

The lavatory is inaccessible because the rim or counter is 27¼ inches high to the bottom.

TR11

24 months

1.5.e 

The designated accessible stall is incorrectly configured as an ambulatory stall, and there is no standard accessible stall provided.

ST15

30 months

1.6

Drinking Fountains: Ground Floor.  The drinking fountain is inaccessible because it requires 11 pounds of force to operate.

DF2

12 months

1.7

Ramp To Stage:  1st Floor.  The ramp is inaccessible because the handrails do not have extensions at the top and bottom, they are mounted 2 inches from the wall, and the ends are not rounded or returned.

R4

30 months

1.8

Department of Finance.  The counter is inaccessible because it is 40½ inches high.

C6

24 months

1.9

Contract Compliance Room 1700.  The pull side of the door, which is accessed through a front approach, has 8½ inches of clearance on the latch side.

D6

30 months

1.10

Water Department Reception.  The Water Department Reception counter protrudes into the walkway and is not detectable to blind persons using a cane.

AR8

30 months

1.11

Unisex Single-User Toilet Room 1st Floor: By Room 1450

   

1.11.a 

The toilet room door swings into the required clear floor space at the lavatory.

TR6

30 months

1.11.b 

No accessible mirror has been provided.

TR14

12 months

1.11.c 

The seat cover dispenser is inaccessible because it is mounted with the controls 58 inches high.

TR5

12 months

1.11.d 

The paper towel dispenser protrudes into the walkway and is not detectable to blind persons using a cane.

AR8

12 months

1.11.e 

The lavatory is inaccessible because the rim or counter is 26¾ inches high to the bottom.

TR11

24 months

1.11.f

The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact.

TR12

24 months

1.11.g 

The toilet is inaccessible because the centerline is 22 inches from the side wall.

SU15

30 months

1.11.h 

The toilet is inaccessible because the flush control is on the closed side.

SU1

30 months

1.11.i

The side grab bar at the toilet is inaccessible because it is obstructed by the toilet paper dispenser.

SU7

12 months

1.11.j

The toilet is inaccessible because both rear grab bars are 24 inches long; one grab bar is approximately 47 inches high and is mounted with the near end more than 6 inches from the side wall; and the other grab bar is obstructed by the flush valve and the higher grab bar and is mounted ¾ inches from the wall where it is bent around the pipe.

SU2

30 months

1.12

Unisex Single-User Toilet Room 1st Floor: By Room 1750

   

1.12.a 

The toilet room door swings into the required clear floor space at the lavatory.

TR6

24 months

1.12.b 

No accessible mirror has been provided.

TR14

12 months

1.12.c 

The paper towel dispenser protrudes into the walkway and is not detectable to blind persons using a cane.

AR8

12 months

1.12.d 

The lavatory is inaccessible because the rim or counter is 25½ inches high to the bottom.

TR11

24 months

1.12.e 

The side grab bar at the toilet is inaccessible because it is obstructed by the toilet paper dispenser.

SU7

12 months

1.12.f

The toilet is inaccessible because both rear grab bars are 24 inches long; one grab bar is approximately 47 inches high; and the other grab bar is obstructed by the flush valve and the higher grab bar and is mounted ¾ inches from the wall where it is bent around the pipe

SU2

30 months

1.13

Drinking Fountains 1st Floor: West Side By Room 1450.  The drinking fountain is inaccessible because the height of the water flow is 1 inch, and the controls require 9 pounds of force to operate.

DF1

12 months

1.14

Drinking Fountains 1st Floor: East Side By Room 1750.  The drinking fountain is inaccessible because the controls require 9 pounds of force to operate.

DF2

12 months

1.15

1st Floor: Procurement Room 1790.  The counter is inaccessible because it is 43½ inches high.

C6

24 months

1.16

1st Floor: Constituent Services Room 1920

   

1.16.a 

The counter is inaccessible because it is 43 inches high.

C6

24 months

1.16.b 

The counter protrudes into the walkway and is not detectable to blind persons using a cane.

AR8

24 months

1.17

1st Floor: Conference Room 1900.  The pull side of the door, which is accessed through a front approach, has only 8 inches of clear space on the latch side.

D6

24 months

1.18

Elevators: Cab 2.  The elevator is inaccessible because the hoistway signage does not have Braille.

E12

24 months

1.19

2nd Floor: Council Chambers

   

1.19.a 

The Council Chamber, containing 230 fixed seats, is inaccessible because no wheelchair seating areas are provided.  A total of 4 wheelchair seating areas is required.

AA6

30 months

1.19.b 

The ramp to the council platform is inaccessible because it has a slope of 12.2% near the top, a landing 38 inches by 42 inches at the change in direction, and the handrails are 31 inches high and mounted 2½ inches from the wall.

R3

30 months

1.20

Accessible Route 2nd Floor: From Elevators to Conference Room #1.  The defibrillator protrudes into the walkway and would not be detectable to a blind person using a cane.

AR8

12 months

1.21

Women’s and Men’s Toilet Room with Stalls:  2nd Floor East and West Side.  The toilet rooms lack accessible directional signage with the International Symbol of Accessibility indicating the location of the nearest accessible toilet room.

TR16

12 months

1.22

3rd Floor: HVAC Division Room 3700

   

1.22.a 

The pull side of the door, which is accessed through a front approach, has 14½ inches of clear space on the latch side.

D6

24 months

1.22.b 

The counter is inaccessible because it is 43 inches high.

C6

24 months

1.22.c 

The counter protrudes into the walkway and is not detectable to blind persons using a cane.

AR8

24 months

1.23

3rd Floor: Helen Smith, Arborist

   

1.23.a 

The counter is inaccessible because it is 43 inches high.

C6

24 months

1.23.b 

The counter protrudes into the walkway and is not detectable to blind persons using a cane.

AR8

24 months

1.24

3rd Floor:  Main Electrical.  The counter protrudes into the walkway and is not detectable to blind persons using a cane.

AR8

24 months

1.25

3rd Floor:  Bureau of Buildings Room 3900.  The computer desks are inaccessible because they do not have sufficient knee space.

C3

24 months

1.26

3rd Floor:  Bureau of Planning Room 3350.  The courtesy phone is inaccessible because it is mounted 60 inches high.

TR5

12 months

1.27

3rd Floor: Housing Code Enforcement Room 3450

   

1.27.a 

The counter is inaccessible because it is 42½ inches high.

C6

24 months

1.27.b 

The counter protrudes into the walkway and is not detectable to blind persons using a cane.

AR8

24 months

1.28

Unisex Single-User Toilet Room 3rd Floor Near Room 3800.  The toilet room lacks accessible directional signage with the International Symbol of Accessibility indicating the location of the nearest accessible toilet room.

TR16

12 months

1.29

Unisex Single-User Toilet Room 3rd Floor Near Room 3450.  The toilet room lacks accessible directional signage with the International Symbol of Accessibility indicating the location of the nearest accessible toilet room.

TR16

12 months

1.30

Drinking Fountain 4th Floor: Near Room 4700.  The drinking fountain is inaccessible because the controls require 9 pounds of force to operate.

DF2

24 months

1.31

Unisex Single-User Toilet Room 4th Floor Near Room 4800.  The toilet room lacks accessible directional signage with the International Symbol of Accessibility indicating the location of the nearest accessible toilet room.

TR16

12 months

1.32

4th Floor: Public Works Department (Under Construction).  The counter is inaccessible because it is 44 inches high.

C6

24 months

1.33

4th Floor: Sanitary Services Room 4800.  The counter protrudes into the walkway and is not detectable to blind persons using a cane.

AR8

24 months

1.34

4th Floor: Traffic and Transportation Room 4900.  The counter is inaccessible because it is 42 inches high.

C6

24 months

1.35

Drinking Fountains 4th Floor: Near Room 4400.  The drinking fountain is inaccessible because the controls require 20 pounds of force to operate.

DF2

12 months

1.36

Women’s Toilet Room With Stalls 4th Floor Near Room 4400.  The toilet room lacks accessible directional signage with the International Symbol of Accessibility indicating the location of the nearest accessible toilet room.

TR16

12 months

1.37

Men’s Toilet Room With Stalls 4th Floor Near Room 4400.  The toilet room lacks accessible directional signage with the International Symbol of Accessibility indicating the location of the nearest accessible toilet room.

TR16

12 months

2 

ATLANTA CITY HALL TOWER, located at 68 Mitchell St., NW

   

2.1

Entrances.  The accessible entrances are locked at all times, and a call button is provided.

D14

24 months

2.2

Interior Doors.  Many of the interior doors throughout the facility are inaccessible because they require more than 5 pounds of force to open.

D2

24 months

2.3

Interior Signage.  The signage provided throughout the facility is inaccessible because it lacks raised and Braille characters.

D26

24 months

2.4

Interior Routes.  The AED’s throughout the facility protrude into the walkway and are not detectable to blind persons using a cane.

AR8

12 months

2.5

Elevators 2 and 3

   

2.5.a 

The elevators are inaccessible because the hall lanterns provide no audible arrival signal on some floors.

E11

24 months

2.5.b 

The elevator is inaccessible because the hall call buttons are mounted 38½ inches high on some floors.

E3

24 months

2.5.c 

The elevator is inaccessible because the hoistway signage is mounted 47 inches high.

E12

24 months

2.5.d 

The elevator is inaccessible because the emergency communications system is not identified by raised lettering, the door requires tight grasping to open, and the handset cord is less than 29 inches long.

E8

24 months

2.6

Exterior Route: From Corner of Mitchell & Washington to Entrance Ramp.  The route is inaccessible because it has uneven and broken pavement, and it slopes between 6.4% and 8.1% without having any ramp features.

AR1

30 months

2.7

Exterior Ramp: To City Hall Tower Washington St. Entrance.  The ramp is inaccessible because it slopes 9.1% at the bottom and 10.9% at the top, there is no edge protection at the drop off sides, and the handrails lack 12 inch long extensions at the bottom.

R5

30 months

2.8

Drinking Fountains 2nd Floor

   

2.8.a 

Both drinking fountains are inaccessible because the flow of water is less than 4 inches high.

DF7

12months

2.8.b 

The drinking fountains protrude into the walkway and are not detectable to blind persons using a cane.

AR8

12 months

2.9

Women’s Toilet Room With Stalls 3rd Floor

   

2.9.a 

The seat cover dispenser is inaccessible because it is mounted 62 inches above the finished floor.

TR5

12 months

2.9.b 

The lavatory is inaccessible because the rim or counter is 26½ inches high to the bottom.

TR11

24 months

2.9.c 

The side grab bar at the designated accessible toilet is inaccessible because it is obstructed by the toilet paper dispenser.

ST8

12 months

2.9.d 

The side grab bar at the designated accessible toilet is inaccessible because it is mounted 2 inches from the side wall and with the far end 45 inches from the rear wall.

ST6

12 months

2.9.e 

The rear grab bar at the toilet is inaccessible because it is 33 inches long, it is obstructed by the flush valve, and it is mounted a varying distance from the rear wall.

ST3

30 months

2.10

Men’s Toilet Room With Stalls 3rd Floor

   

2.10.a 

The seat cover dispenser is inaccessible because it is mounted 62 inches above the finished floor.

TR5

12 months

2.10.b 

The lavatory is inaccessible because the rim or counter is 26½ inches high to the bottom.

TR11

24 months

2.10.c 

The urinal is inaccessible because its rim is 22 inches above the finished floor.

TR20

24 months

2.10.d 

The designated accessible toilet is inaccessible because the flush control is on the closed side.

ST2

30 months

2.10.e 

The side grab bar at the designated accessible toilet is inaccessible because it is obstructed by the toilet paper dispenser.

ST8

12 months

2.10.f

The side grab bar at the designated accessible toilet is inaccessible because it is 35 inches long and is mounted a varying distance from the side wall with the far end 38½ inches from the rear wall.

ST6

24 months

2.10.g 

The rear grab bar at the toilet is inaccessible because it is 33 inches long, is obstructed by the flush valve, and is mounted a varying distance from the rear wall.

ST3

24 months

2.11

3rd Floor: HR Policy and Planning Room 3200.  The door is inaccessible because it has knob hardware.

D1

24 months

2.12

3rd Floor: Auditorium Room 3100.  The auditorium is inaccessible because it has no assistive listening system provided.

AA5

24 months

2.13

Drinking Fountain 4th Floor

   

2.13.a 

The drinking fountain is inaccessible because the controls require 8 pounds of force to operate.

DF2

12 months

2.13.b 

The drinking fountain protrudes into the walkway and is not detectable to blind persons using a cane.

AR8

12 months

2.14

Men’s Single-User Toilet Room 4th Floor Near Snack Bar Area.  The toilet room lacks accessible directional signage with the International Symbol of Accessibility indicating the location of the nearest accessible toilet room.

T16

12 months

2.15

Women’s Single-User Toilet Room 4th Floor Near Snack Bar Area.  The toilet room lacks accessible directional signage with the International Symbol of Accessibility indicating the location of the nearest accessible toilet room.

TR16

12 months

2.16

5th Floor: Law Department Suite 5100

   

2.16.a 

The exit sign protrudes into the walkway and is not detectable to blind persons using a cane.

AR8

24 months

2.16.b 

The drinking fountain is inaccessible because the control requires 6 pounds of force to operate.

DF2

12 months

2.16.c 

The drinking fountain protrudes into the walkway and is not detectable to blind persons using a cane.

AR8

12 months

2.17

Inaccessible 5th Floor Toilet Rooms.  The toilet rooms lack accessible directional signage with the International Symbol of Accessibility indicating the location of the nearest accessible toilet room.

TR16

24 months

2.18

Drinking Fountain 5th Floor Atrium: East.  The drinking fountain is inaccessible because the water flow is less than 4 inches high.

DF7

12 months

2.19

6th Floor: Accounts Payable Suite 6100

   

2.19.a 

The exit sign protrudes into the walkway and is not detectable to blind persons using a cane.

AR8

24 months

2.19.b 

The counter protrudes into the walkway and is not detectable to blind persons using a cane.

AR8

24 months

2.19.c 

The route to room 6190 is inaccessible because it narrows to 28½ inches wide.

AR3

24 months

3 

CYCLORAMA & CIVIL WAR MUSEUM, located at 800-C Cherokee Ave, SE

   

3.1

Parking.  In the parking lot, with a total of 316 parking spaces, all of the rear tier of designated accessible parking spaces have “Van-Accessible” signage, although 5 of the spaces do not have van accessible access aisles, and the 4 van accessible parking spaces nearest to the zoo entrance have no vertical signage.  This lot requires 1 van accessible space and 7 standard accessible spaces.

P3

30 months

3.2

Accessible Route.  The route leading to the exterior entrance is inaccessible because the running slope is 8.7% and the route has no ramp features.

AR1

30 months

3.3

1st Floor Auditorium

   

3.3.a 

The door is inaccessible because it requires 10 pounds of force to open.

D2

12 months

3.3.b 

The auditorium, with 187 fixed seats, is inaccessible because a fixed companion seat is not provided for all wheelchair seating locations.

AA6

30 months

3.3.c 

The ramp on the route connecting the wheelchair seating areas and the stage is inaccessible because it has a handrail on only one side, the existing handrail has no extensions at the top or bottom, and the ramp lacks edge protection.

R5

30 months

3.3.d 

The auditorium is inaccessible because it lacks fixed aisle seating without armrests.

AA2

30 months

3.3.e 

There is no signage informing the public of the availability of an assistive listening system.

AA3

30 months

3.4

Women’s Toilet Room with Stalls 1st Floor

   

3.4.a 

The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact.

TR12

24 months

3.4.b 

The designated accessible stall is incorrectly configured as an ambulatory stall, and there is no standard accessible stall provided.

ST15

30 months

3.5

Men’s Toilet Room With Stalls 1st Floor

   

3.5.a 

The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact.

TR12

24 months

3.5.b 

The lavatory is inaccessible because it has twist-type hardware.

TR10

24 months

3.5.c 

The lower urinal is inaccessible because the rim is 19 inches high.

TR20

24 months

3.5.d 

The designated accessible stall is incorrectly configured as an ambulatory stall, and there is no standard accessible stall provided.

ST15

30 months

3.6

Elevator.  The elevator is inaccessible because the car control buttons do not have Braille or raised characters to the left of the buttons and the main entry floor is not designated by a raised star.

E4

30 months

3.7

Interior Accessible Route: 1st Floor.  The area under the escalators is inaccessible because there are less than 80 inches of head room provided.

AR7

24 months

3.8

Ramp: From Auditorium to Cyclorama.  The ramp is inaccessible because the handrails are mounted 32½ inches high.

R4

24 months

3.9

Cyclorama.  The Cyclorama is inaccessible because there are no fixed companion seats next to the wheelchair locations.

AA6

30 months

4 

ATLANTA POLICE DEPARTMENT ZONE 2, located at 3120 Maple Drive

   

4.1

Parking.  The parking lot, with a total of 43 parking spaces, is inaccessible because it only has no spaces designated as accessible.  This lot requires 1 van accessible space and 1 standard accessible space.

P3

24 months

4.2

Accessible Route: From Parking Lot to Exterior Entrance.  The route is inaccessible because a barrel and sign placed in the walkway obstruct the route and because the surface has a change in level in excess of ½ inch vertically.

AR1

30 months

4.3

Front Desk Counter.  The counter protrudes into the walkway and is not detectable to blind persons using a cane.

AR8

24 months

4.4

Men’s Toilet Room With Stalls

   

4.4.a 

The toilet room sign is mounted on the door and has no raised or Braille characters.

TR18

12 months

4.4.b 

The door is inaccessible because it requires 15 pounds of force to open.

D2

12 months

4.4.c 

The pull side of the door to the toilet room, which is accessed through a front approach, is inaccessible because the maneuvering space is obstructed by a table.

D6

12 months

4.4.d 

There is no accessible toilet stall provided.

ST15

30 months

4.5

Women’s Single-User Toilet Room

   

4.5.a 

The toilet room sign is mounted on the door and has no raised or Braille characters.

TR18

12 months

4.5.b 

The pull side of the door to the toilet room, which is accessed through a front approach, is inaccessible because the maneuvering space is blocked by a chair.

D6

12 months

4.5.c 

The push side of the door to the women’s toilet room, which is accessed through a front approach and which has both a closer and a latch, is inaccessible because it has only 9 inches of clearance on the latch side.

D7

30 months

4.5.d 

There is insufficient turning space within the toilet room.

TR19

30 months

4.5.e 

The toilet is inaccessible because the centerline is 19 inches from the side wall.

SU15

30 months

4.5.f

The toilet is inaccessible because the flush control is on the closed side.

SU1

30 months

4.5.g 

The overall length of the side grab bar is 30 inches and the distance from the farther end to the rear wall is 33½ inches.

SU6

24 months

4.5.h 

The overall length of rear grab bar is 24 inches, and the distance from the closer end to the side wall is 6½ inches.

SU3

24 months

5 

ATLANTA POLICE DEPARTMENT ZONE 6, located at 2025 Hosea Williams Drive, SE

   

5.1

Accessible Route: Ramp.  The ramp on the route to the main entrance is inaccessible because it slopes up to 12.1%, the cross-slope is greater than 2.0%, the bottom landing is not level, and the handrails are 33 inches high and lack extensions.

R5

30 months

5.2

Exterior Entrance and Doors.  The building does not have directional signage posted at inaccessible entrances and does not have the International Symbol of Accessibility posted at accessible entrances.

D16

12 months

5.3

Men’s Single-User Toilet Room

   

5.3.a 

The toilet room sign is mounted on the door and has no raised and Braille characters.

TR18

24 months

5.3.b 

The door swings into the clear floor space of the lavatory.

TR6

30 months

5.3.c 

Although an audible alarm is provided in this facility, there is no visual alarm appliance in the toilet room.

TR21

30 months

5.3.d 

No accessible mirror has been provided.

TR14

12 months

5.3.e 

The lavatory is inaccessible because the rim or counter is 27 inches high to the bottom.

TR11

24 months

5.3.f

The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact.

TR12

24 months

5.3.g 

The toilet is inaccessible because the flush control is mounted on the closed side.

SU1

30 months

5.3.h 

There is no accessible toilet paper dispenser provided.

SU17

12 months

5.3.i

The rear grab bar at the toilet is inaccessible because it is mounted 7 inches from the side wall.

SU3

12 months

5.4

Women’s Single-User Toilet Room

   

5.4.a 

The toilet room sign is mounted on the door and has no raised and Braille characters.

TR18

24 months

5.4.b 

The second door leading to the toilet room is blocked by a ladder and prevented from opening to a 90 degree angle.

D25

12 months

5.4.c 

Although an audible alarm is provided in this facility, there is no visual alarm appliance in the toilet room.

TR21

30 months

5.4.d 

No accessible mirror has been provided.

TR14

12 months

5.4.e 

The lavatory is inaccessible because the rim or counter is 27¼ inches high to the bottom.

TR11

24 months

5.4.f

The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact.

TR12

24 months

5.4.g 

The toilet is inaccessible because the top of the seat is 16 inches high.

SU18

30 months

5.4.h 

The toilet is inaccessible because there is insufficient clear floor space due to the lavatory post.

SU16

30 months

5.4.i

The toilet is inaccessible because the centerline is 16 inches from the wall.

SU15

30 months

5.4.j

The toilet is inaccessible because the flush control is mounted on the closed side.

SU1

30 months

6 

BOISFEUILLET JONES ATLANTA CIVIC CENTER, located at 395 Piedmont Ave, NE

   

6.1

Parking.  All of the lots, which have a total of 882 parking spaces, have a total of 24 designated accessible parking spaces, many of which have slopes and cross-slopes exceeding 2% or are lacking vertical signage; there is no “Van-Accessible” signage; and several of the designated accessible spaces are in the Piedmont lot, which has no access aisles and no accessible route to an accessible entrance.  This lot requires 3 van accessible spaces and 15 standard accessible spaces.

P3

30 months

6.2

Accessible Route: From Parking To Entrance

   

6.2.a 

On the routes from both sides of the parking lot to the entrance, the slope of most of the curb cuts is greater than 8.33%, and some of the flared sides slope greater than 10%.

AR5

30 months

6.2.b 

On the route from the left side of the parking lot to the entrance, the slope between the planters is 5.2% with no ramp features; on the route from the right side of the parking lot to the entrance, the slope between the planters is 8% and the slope on the island is 7.8% with no ramp features; and on the routes from both sides, there is broken asphalt creating level changes exceeding ½ inch.

AR1

30 months

6.2.c 

The route from the right side of the parking to the entrance is inaccessible because the underside of the stairs provides less than 80 inches of head room.

AR7

24 months

6.3

Main Entrance - East - Passenger Loading Zone.  The slope of the primary curb cut is 13.6%, and the slope of the flared sides is 22% and 25%.

AR5

30 months

6.4

Exterior Entrances.  The building does not have directional signage posted at inaccessible entrances and does not have the International Symbol of Accessibility posted at accessible entrances.

D16

12 months

6.5

Public Elevators

   

6.5.a 

The elevator is inaccessible because the call buttons are centered at 49 inches above the finished floor and are recessed.

E3

30 months

6.5.b 

The elevator is inaccessible because hall lanterns are not provided.

E11

30 months

6.5.c 

The elevator is inaccessible because it lacks signage at hoistway entrances.

E12

30 months

6.5.d 

The elevator is inaccessible because it does not emit an audible signal as the car passes or stops at a floor.

E5

30 months

6.6

Assembly Area: Piedmont Room A & B

   

6.6.a 

The Piedmont room is inaccessible to people with hearing disabilities because there is no assistive listening system provided.

AA5

30 months

6.6.b 

There is no accessible route connecting the wheelchair seating areas and the portable stage.

AA1

30 months

6.7

Staff Toilet Rooms By Piedmont Meeting Room.  Although these are staff-only toilet rooms, they are used by the public, and there is no signage directing people with disabilities to the accessible public toilet rooms.

TR16

24 months

6.8

Accessible Route: From East Entrance to Orchestra Level.  The doors on the route from the east entrance to the orchestra level are inaccessible because they have an opening width of only 29 inches.

D25

30 months

6.9

Women’s Toilet Room With Stalls: Orchestra Level

   

6.9.a 

The toilet room sign is mounted above the door and has no raised or Braille characters.

TR18

24 months

6.9.b 

There is no side grab bar provided at the designated accessible toilet.

ST6

24 months

6.9.c 

The rear grab bar at the designated accessible toilet is inaccessible because it is obstructed by the toilet flush valve.

ST5

24 months

6.9.d 

Although there are 14 stalls, there is no ambulatory stall provided.

ST1

30 months

6.10

Men’s Toilet Room With Stalls: Orchestra Level

   

6.10.a 

The toilet room sign is mounted above the door and has no raised or Braille characters.

TR18

24 months

6.10.b 

The urinals are inaccessible because they are mounted with their rims 20½ inches above the finished floor.

TR20

30 months

6.10.c 

The rear grab bar at the designated accessible toilet is inaccessible because it is obstructed by the toilet flush valve.

ST5

24 months

6.10.d 

Although there are 6 stalls, there is no ambulatory stall provided.

ST1

30 months

6.11

Drinking Fountains: Orchestra Level

   

6.11.a 

The drinking fountain is inaccessible because the control requires 10 pounds of force to operate.

DF2

12 months

6.11.b 

The drinking fountain protrudes into the walkway and is not detectable to blind persons using a cane.

AR8

12 months

6.12

Accessible Route To Orchestra Level Seats.  The route leading to the Orchestral Level seats is inaccessible because the slope of one leg is 10.1%, the slope of the landing between the legs is 3.5%, and handrails are not provided.

R3

30 months

6.13

Auditorium

   

6.13.a 

The seating is inaccessible because the wheelchair locations do not have fixed companion seats.

AA6

30 months

6.13.b 

There is no accessible route connecting the wheelchair seating areas and the stage.

AA1

30 months

6.14

Plaza Box Office Ticket Window.  The counter at the ticket window is 42 inches above the finished floor and a clipboard is unable to fit through the opening.

C6

24 months

6.15

Drinking Fountain: Plaza Level

   

6.15.a 

The drinking fountain is inaccessible because the control requires 12 pounds of force to operate.

DF2

12 months

6.15.b 

The drinking fountain protrudes into the walkway and is not detectable to blind persons using a cane.

AR8

12 months

6.16

Women’s Toilet Room With Stalls: Plaza Level

   

6.16.a 

The toilet room sign is mounted above the door and has no raised or Braille characters.

TR18

24 months

6.16.b 

The seat cover dispenser is mounted 56½ inches above the finished floor.

TR5

12 months

6.16.c 

Left Standard Toilet Stall

   

6.16.c.1 

 

The toilet is inaccessible because the centerline is 24 inches from the side partition.

ST17

30 months

6.16.c.2 

 

The toilet is inaccessible because the side grab bar is obstructed by the toilet seat cover dispenser.

ST9

12 months

6.16.c.3 

 

The toilet is inaccessible because the rear grab bar is mounted 13 inches from the side wall.

ST4

12 months

6.16.d 

Right Standard Toilet Stall

   

6.16.d.1 

 

The toilet is inaccessible because the stall is 57½ inches wide.

ST16

30 months

6.16.d.2 

 

The toilet is inaccessible because the side grab bar is obstructed by the toilet seat cover dispenser.

ST9

12 months

6.17

Accessible Route: Plaza Level

   

6.17.a 

The route from the front entrance is inaccessible because there are only 55 inches of head room provided under the stairs.

AR7

24 months

6.17.b 

The defibrillator protrudes into the walkway and is not detectable to blind persons using a cane.

AR8

12 months

6.18

Men’s Toilet Room With Stalls: Loge Level

   

6.18.a 

The toilet room sign is mounted above the door and has no raised or Braille characters.

TR18

24 months

6.18.b 

The urinals are inaccessible because their rims are 20 inches high.

TR20

30 months

6.18.c 

Although there are 6 stalls, there is no ambulatory stall provided.

ST1

30 months

6.18.d 

The designated accessible toilet is inaccessible because the stall is 56½ inches deep with a floor-mounted toilet.

ST16

30 months

6.18.e 

The designated accessible toilet is inaccessible because its centerline is 16 inches from the side wall.

ST17

30 months

6.18.f

There is no accessible coat hook provided.

TR1

12 months

6.18.g 

The designated accessible toilet is inaccessible because the rear grab bar is obstructed by the flush valve.

ST5

30 months

6.19

Women’s Toilet Room With Stalls: Loge Level

   

6.19.a 

The toilet room sign is mounted above the door and has no raised or Braille characters.

TR18

24 months

6.19.b 

The designated accessible toilet is inaccessible because its centerline is 16 inches from the side wall.

ST17

30 months

6.19.c 

Although there are 13 stalls, there is no ambulatory stall provided.

ST1

30 months

6.19.d 

The designated accessible toilet is inaccessible because the flush control is on the closed side.

ST2

30 months

6.19.e 

The designated accessible toilet is inaccessible because the rear grab bar is obstructed by the flush valve.

ST5

30 months

6.20

Drinking Fountain: Loge Level

   

6.20.a 

The drinking fountain is inaccessible because the control requires 7 pounds of force to operate.

DF2

12 months

6.20.b 

The drinking fountain protrudes into the walkway and is not detectable to blind persons using a cane.

AR8

12 months

6.21

Auditorium: Loge Level

   

6.21.a 

Each leaf of the double entry doors is inaccessible because it has an opening width of 29½ inches and requires 12 pounds of force to open.

D5

30 months

6.21.b 

The seating is inaccessible because the slope of the wheelchair locations is 4.4%, the cross-slope is 7.5%, and the wheelchair seating areas lack fixed companion seating.

AA6

30 months

6.22

Auditorium: Balcony Level

   

6.22.a 

A pipe protrudes into the walkway on the route to the balcony seating that is not detectable to blind persons using a cane.

AR8

30 months

6.22.b 

Each leaf of the double doors to the Balcony Level seating is inaccessible because it has an opening width of only 30 inches and requires 11 pounds of force to open.

D5

30 months

6.23

Accessible Dressing Room No. 8

   

6.23.a 

Although an audible alarm is provided in this facility, there is no visual alarm appliance in the toilet room.

TR21

30 months

6.23.b 

The shower stall is inaccessible because the clear floor space outside the stall is inadequate, the transfer seat does not extend the full depth of the stall, and a grab bar is not provided on the back wall.

B8

30 months

6.24

Drinking Fountain: Back Stage Area.  The drinking fountain protrudes into the walkway and is not detectable to blind persons using a cane.

AR8

12 months

6.25

Elevator: Backstage Freight

   

6.25.a 

The elevator is inaccessible because the hall call buttons are centered 51 inches high and they have a diameter less than ¾ inches.

E3

30 months

6.25.b 

The elevator is inaccessible because it lacks hall lanterns.

E11

30 months

6.25.c 

The elevator is inaccessible because it lacks hoistway signage.

E12

30 months

6.25.d 

The elevator is inaccessible because it lacks a door protective and reopening device.

E6

30 months

6.25.e 

The elevator is inaccessible because the car control buttons are less than ¾ inches in dimension and lack Braille and raised characters, the highest button is 61½  inches above the car floor, car position indicators are not provided, and the main entry floor call button is not designated by a raised star.

E4

30 months

6.25.f

The elevator is inaccessible because, although emergency communications are provided, the door to the emergency communications requires tight pinching to open.

E8

30 months

6.26

Accessible Route: Main Lobby Exhibition Hall. The route through the main lobby is inaccessible because the underside of the stairs provides less than 80 inches of head room.

AR7

30 months

6.27

Exhibition Hall Main Lobby Box Office (Temporary With Exhibit).  The lobby box office counter is inaccessible because it is 46 inches high.

C6

12 months

6.28

Men’s Toilet Room with Stalls: Exhibition Hall

   

6.28.a 

The toilet room sign is less than 60 inches high and has no raised or Braille characters.

TR18

24 months

6.28.b 

Although an audible alarm is provided in this facility, there is no visual alarm appliance in the toilet room.

TR21

30 months

6.28.c 

The paper towel dispenser is inaccessible because the controls are mounted 59 inches high.

TR5

12 months

6.28.d 

The urinals are inaccessible because their rims are 20 inches high.

TR20

30 months

6.28.e 

There is no accessible toilet stall provided.

ST15

30 months

6.28.f

The ambulatory stall has partitions 37 inches apart, and the toilet paper dispenser is mounted above one side grab bar.

ST1

30 months

6.29

Women’s Toilet Room with Stalls: Exhibition Hall

   

6.29.a 

The toilet room sign is less than 60 inches high and has no raised or Braille characters.

TR18

24 months

6.29.b 

Although an audible alarm is provided in this facility, there is no visual alarm appliance in the toilet room.

TR21

30 months

6.29.c 

No accessible mirror has been provided.

TR14

12 months

6.29.d 

The paper towel dispenser is inaccessible because the controls are mounted 60 inches high.

TR5

12 months

6.29.e 

The lavatory is inaccessible because the rim or counter is 27 inches high to the bottom.

TR11

24 months

6.29.f

There is no accessible toilet stall provided.

ST15

30 months

6.29.g 

The ambulatory stall has partitions 38 inches apart, and the toilet paper dispenser is mounted above one side grab bar.

ST1

30 months

6.30

Drinking Fountain: Exhibition Hall by Toilet Rooms

   

6.30.a 

The drinking fountain is inaccessible because the control requires 12 pounds of force to operate.

DF2

12 months

6.30.b 

Although a designated accessible drinking fountain is provided, there is no drinking fountain provided for people who have difficulty bending or stooping.

DF3

30 months

6.31

Public Elevator: Exhibition Hall

   

6.31.a 

The elevator is inaccessible because the hall call buttons are recessed.

E3

30 months

6.31.b 

The elevator is inaccessible because the doors fail to reopen without contact when obstructed.

E6

30 months

6.31.c 

The elevator is inaccessible because the car control buttons are recessed, raised characters are not provided, and the call button for the main entry floor is not designated by a raised star.

E4

30 months

6.32

Accessible Route: Exhibition Hall 1st Floor.  The route is inaccessible because adequate head room is not provided in the exit area under the stairs.

AR7

30 months

6.33

Exhibition Hall 2nd Floor Meeting Room

   

6.33.a 

The door is inaccessible because it requires 9 pounds of force to open and the hardware is mounted 53 inches above the floor and requires twisting to operate.

D1

D18

24 months

6.33.b 

The meeting room is inaccessible to people with hearing disabilities because no assistive listening system is provided.

AA5

30 months

6.34

Drinking Fountain: Exhibition Hall 2nd Floor Meeting Room.  Although a designated accessible drinking fountain is provided, there is no drinking fountain provided for people who have difficulty bending or stooping.

DF3

30 months

6.35

Women’s Toilet Room Single-User: Exhibition Hall 2nd Floor Meeting Room

   

6.35.a 

The toilet room sign is mounted on the door and does not have raised or Braille characters.

TR18

24 months

6.35.b 

Although an audible alarm is provided in this facility, there is no visual alarm appliance in the toilet room.

TR21

30 months

6.35.c 

The toilet is inaccessible because its centerline is 19½ inches from the side wall.

SU15

30 months

6.36

Men’s Toilet Room Single-User: Exhibition Hall 2nd Floor Meeting Room

   

6.36.a 

The toilet room sign is mounted on the door and does not have raised or Braille characters.

TR18

24 months

6.36.b 

Although an audible alarm is provided in this facility, there is no visual alarm appliance in the toilet room.

TR21

30 months

6.36.c 

The paper towel dispenser is inaccessible because the controls are mounted at 56 inches high.

TR5

12 months

6.36.d 

The toilet is inaccessible because there is insufficient clear floor space due to the placement of the lavatory.

SU16

30 months

6.36.e 

The toilet is inaccessible because its centerline is 19 inches from the side wall.

SU15

30 months

6.36.f

The toilet is inaccessible because the flush control is on the closed side.

SU1

30 months

6.36.g 

The rear grab bar at the toilet is inaccessible because its overall length is 24 inches.

SU3

24 months

7 

CANDLER PARK GOLF COURSE, located at 585 Candler Park Dr, NE

   

7.1

Parking Lot.  Although the parking lot has a total of 5 parking spaces, there are no accessible parking spaces provided.  This lot requires 1 van accessible space.

P3

24 months

7.2

Club House Main Entrance

   

7.2.a 

The Club House is inaccessible because there is a 4 inch step on the route leading to the main entrance.

AR1

30 months

7.2.b 

The main entrance door is inaccessible because it has an opening width of only 28 inches per leaf.

D25

30 months

7.2.c 

The main entrance door is inaccessible because it has a 1½ inch high threshold.

D23

24 months

7.3

Counter.  The counter in the clubhouse is inaccessible because it is 39½ inches high.

C6

24 months

7.4

Men’s & Women’s Toilet Rooms with Stalls.  The men’s and women’s toilet rooms contain a number of inaccessible elements and are not accessible to people with disabilities.

ST14

30 months

7.5

Drinking Fountain.  The drinking fountain is inaccessible because the spout is 43 inches high.

DF6

12 months

8 

OAKLAND RECREATION CENTER, located at 1305 Oakland Rd, SW

   

8.1

Parking Lot.  The parking reserved for persons with disabilities is inaccessible because it lacks appropriate vertical signage.

P6

24 months

8.2

Women’s Toilet Room With Stalls: 1st Floor

   

8.2.a 

The door is inaccessible because it requires 7 pounds of force to open.

D2

12 months

8.2.b 

No accessible mirror has been provided.

TR14

12 months

8.2.c 

The air dryer protrudes into the walkway and is not detectable to blind persons using a cane.

AR8

12 months

8.2.d 

The lavatory is inaccessible because it has no knee or toe clearance.

TR11

24 months

8.2.e 

There is no standard accessible stall provided.

ST15

30 months

8.3

Men’s Toilet Room With Stalls: 1st Floor

   

8.3.a 

The door is inaccessible because it requires 8 pounds of force to open.

D2

12 months

8.3.b 

No accessible mirror has been provided.

TR14

12 months

8.3.c 

The urinal is inaccessible because its rim is 23 inches high.

TR20

24 months

8.3.d 

The air dryer protrudes into the walkway and is not detectable to blind persons using a cane.

AR8

12 months

8.3.e 

The lavatory is inaccessible because it has no knee or toe clearance.

TR11

24 months

8.3.f

There is no standard accessible stall provided.

ST15

30 months

8.4

Drinking Fountain.  The drinking fountain protrudes into the walkway and is not detectable to blind persons using a cane.

AR8

12 months

9 

ADAMS PARK & RECREATION CENTER, located on Delowe Dr, SW

   

9.1

Parking Lot.  The parking lot, with a total of 6 parking spaces, has no van accessible parking space, and the existing designated accessible parking space has no access aisle and no vertical signage.  This lot requires 1 van accessible space.

P3

24 months

9.2

Accessible Route: From Parking Lot To Main Entrance.  The route is inaccessible because the curb ramp is steeper than 8.33%, and although it does not have handrails or guardrails to protect against cross traffic, it also does not have flared sides.

AR5

30 months

9.3

Exterior Entrances.  The building does not have directional signage posted at inaccessible entrances and does not have the International Symbol of Accessibility posted at accessible entrances.

D16

12 months

9.4

Interior Doors.  The interior doors are inaccessible because knob hardware is used.

D1

24 months

9.5

Access Among Levels.  There is no access to upper and lower levels of the facility for people with mobility impairments.

AR9

30 months

9.6

Drinking Fountain

   

9.6.a 

Although an accessible drinking fountain is provided, there is no drinking fountain provided for people who have difficulty bending or stooping.

DF3

30 months

9.6.b 

The drinking fountain protrudes into the walkway and is not detectable to blind persons using a cane.

AR8

12 months

9.7

Women’s Toilet Room With Stalls: 1st Level

   

9.7.a 

The toilet room sign is mounted on the door and has no raised or Braille characters.

TR18

24 months

9.7.b 

The door is inaccessible because it requires 7 pounds of force to open.

D2

12 months

9.7.c 

The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact.

TR12

24 months

9.7.d 

The designated accessible toilet is inaccessible because its centerline is 16½ inches from the side wall.

ST17

30 months

9.7.e 

The designated accessible toilet is inaccessible because the side grab bar is obstructed by the toilet paper dispenser.

ST8

12 months

9.7.f

The grab bars at the designated accessible toilet are inaccessible because they are mounted 30½ inches above the finished floor.

ST12

12 months

9.7.g 

The grab bars at the designated accessible toilet are inaccessible because the space between the grab bars and the wall is 2¾ inches.

ST13

12 months

9.7.h 

The rear grab bar at the designated accessible toilet is inaccessible because it is 24 inches long.

ST4

24 months

9.8

Men’s Toilet Room With Stalls: 1st Level

   

9.8.a 

The toilet room sign is mounted on the door and has no raised or Braille characters.

TR18

24 months

9.8.b 

The door is inaccessible because it requires 8 pounds of force to open.

D2

12 months

9.8.c 

No accessible mirror has been provided.

TR14

12 months

9.8.d 

The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact.

TR12

24 months

9.8.e 

The urinal is inaccessible because the rim is more than 17 inches high.

TR20

24 months

9.8.f

The designated accessible toilet is inaccessible because its centerline is 20½ inches from the side wall.

ST17

30 months

9.8.g 

The designated accessible toilet is inaccessible because the side grab bar is obstructed by the toilet paper dispenser.

ST8

12 months

9.8.h 

The grab bars at the designated accessible toilet are inaccessible because the space between the grab bars and the wall is 2¾ inches.

ST13

24 months

9.8.i

The rear grab bar at the toilet is inaccessible because its overall length is 24 inches and it is mounted with the closer end 12 inches from the side wall.

ST4

24 months

9.9

Spectator Area 1st Floor.  The door is inaccessible because it requires 12 pounds of force to open.

D2

12 months

9.10

Stairs.  The stairs to the basketball court are inaccessible because there are less than 80 inches of head room provided.

AR7

30 months

9.11

Accessible Route: To Tennis Courts.  There is no accessible route to the tennis courts.

AR1

30 months

10 

MCGHEE TENNIS CENTER, located at 820 Beecher Ct, SW

   

10.1

Parking Lot.  The parking lot, with a total of 36 parking spaces, has no van accessible parking space, and has no vertical signage designating accessible parking spaces.  This lot requires 1 van accessible space and 1 standard accessible space.

P3

24 months

10.2

Accessible Route: From Parking Lot to Main Entrance.  The route is inaccessible because the slope of the curb cut is 12.2%, and the flared sides are too steep.

AR5

30 months

10.3

Main Entrance.  The building does not have directional signage posted at inaccessible entrances and does not have the International Symbol of Accessibility posted at accessible entrances.

D16

12 months

10.4

Interior Doors.  The doors are inaccessible because knob hardware is used.

D1

24 months

10.5

Women’s Locker Room: Near Lobby

   

10.5.a 

The sign is mounted on the door and lacks raised and Braille characters.

TR18

24 months

10.5.b 

The door is inaccessible because it requires 11 pounds of force to open.

D2

12 months

10.5.c 

The lavatory is inaccessible because there is no knee space provided.

TR11

24 months

10.5.d 

The designated accessible toilet stall is incorrectly configured as an ambulatory stall, and there is no standard accessible stall provided.

ST15

30 months

10.5.e 

The designated accessible shower has a number of inaccessible elements and is not accessible to people with disabilities.

B8

30 months

10.5.f

The air dryer is inaccessible because the controls are mounted 69 inches above the finished floor.

TR5

12 months

10.5.g 

The bench is inaccessible because it is 9½ inches wide and is not fixed to a wall.

LR1

30 months

10.5.h 

The lockers are inaccessible because they require tight grasping to open.

LR3

30 months

10.6

Men’s Locker Room: Near Lobby

   

10.6.a 

The sign is mounted on the door and lacks raised and Braille characters.

TR18

24 months

10.6.b 

The door is inaccessible because it requires 11 pounds of force to open.

D2

12 months

10.6.c 

The lavatory is inaccessible because there is no knee space provided.

TR11

24 months

10.6.d 

The urinals are inaccessible because their rims are 25 inches high.

TR20

24 months

10.6.e 

The designated accessible toilet stall is incorrectly configured as an ambulatory stall, and there is no standard accessible stall provided.

ST15

30 months

10.6.f

The paper towel dispenser is inaccessible because the controls are mounted more than 54 inches high.

TR5

12 months

10.6.g 

There is no accessible shower provided.

B8

30 months

10.6.h 

The air dryer is inaccessible because the controls are mounted 77 inches above the finished floor.

TR5

12 months

10.6.i

The bench is inaccessible because it is 9½ inches wide and is not fixed to a wall.

LR1

30 months

10.6.j

The lockers are inaccessible because they require tight grasping to open.

LR3

30 months

10.7

Welcome Desk: Lobby Area.  The welcome desk is inaccessible because the counter is 44 inches high.

C6

12 months

10.8

Accessible Route: From Side Exit to Tennis Court #7.  The ramp leading to the tennis court has a 1 inch change in level at the top, has a slope of 10.3% near the bottom, and lacks handrails.

AR1

30 months

11 

GRANT PARK RECREATION CENTER, located at 537 Park Ave, SE

   

11.1

Parking Lot

   

11.1.a 

The parking lot, with a total of 30 parking spaces, has only one designated accessible parking space, which has no access aisle and no vertical signage.  This lot requires 1 van accessible space and 1 standard accessible space.

P3

24 months

11.1.b 

The curb ramp leading to the basketball and tennis courts is inaccessible because it slopes 15%, the cross-slope is 3.2%, there is a ½ change in level at the bottom of the curb ramp, and the flared sides are too steep.

AR5

30 months

11.1.c 

The curb ramp leading to the main entrance under the stairs is inaccessible because it slopes 13.9%, the flared sides are too steep, and there is a ¾ inch change in level at the top of the curb ramp.

AR5

30 months

11.2

Exterior Accessible Route.  The route from the parking lot to the basketball and tennis courts is inaccessible because the running slope is 6% with no ramp features, the cross-slope is 5.5%, and there is a 2½ inch change in level at the entrance of the tennis court.

AR1

30 months

11.3

Main Entrance.  The front entrance is inaccessible because the threshold is 4 inches high.

D23

24 months

11.4

Interior Accessible Route.  There is no access to the 2nd floor of the facility for people with mobility impairments.

AR9

30 months

11.5

Dance Room: 1st Floor.  The dance room is inaccessible because the door has knob hardware.

D1

24 months

11.6

Side Entrance by Game Room

   

11.6.a 

The route to the side entrance by the game room is inaccessible because there is a 3¼ change in level leading to the entrance.

AR1

24 months

11.6.b 

The door is inaccessible because there is a 1 inch high threshold.

D23

24 months

11.7

Classroom: 1st Floor.  The classroom is inaccessible because the door has knob hardware.

D1

24 months

11.8

Women’s Toilet Room With Stalls: 1st Floor

   

11.8.a 

The toilet room sign is not mounted on the latch side of the door and lacks raised and Braille characters.

TR18

24 months

11.8.b 

The door to the toilet room is inaccessible because it has an opening width of only 29 inches.

D25

30 months

11.8.c 

The door is inaccessible because it requires 8 pounds of force to open.

D2

12 months

11.8.d 

The pull side of the door to the toilet room, which is accessed through a front approach, is inaccessible because the clearance on the latch side of the door is only 6 inches wide.

D6

30 months

11.8.e 

No accessible mirror has been provided.

TR14

12 months

11.8.f

The lavatory is inaccessible because the rim or counter is 27 inches high to the bottom.

TR11

24 months

11.8.g 

The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact.

TR12

24 months

11.8.h 

The lavatory is inaccessible because the faucet requires tight grasping or twisting of the wrist to operate.

TR10

24 months

11.8.i

There is no accessible toilet stall provided.

ST15

30 months

11.9

Men’s Toilet Room With Stalls: 1st Floor

   

11.9.a 

The toilet room sign is not mounted on the latch side of the door and lacks raised and Braille characters.

TR18

24 months

11.9.b 

The door to the toilet room is inaccessible because it has an opening width of only 29 inches.

D25

30 months

11.9.c 

The door is inaccessible because it requires 8 pounds of force to open.

D2

12 months

11.9.d 

The pull side of the door to the women’s toilet room, which is accessed through a front approach, is inaccessible because the clearance on the latch side of the door is only 4½ inches wide.

D6

30 months

11.9.e 

No accessible mirror has been provided.

TR14

12 months

11.9.f

The lavatory is inaccessible because the rim or counter is 27 inches high to the bottom.

TR11

24 months

11.9.g 

The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact.

TR12

24 months

11.9.h 

The lavatory is inaccessible because the faucet requires tight grasping or twisting of the wrist to operate.

TR10

24 months

11.9.i

The urinals are inaccessible because the rims are 23 inches high.

TR20

24 months

11.9.j

The designated accessible stall is incorrectly configured as an ambulatory stall, and there is no standard accessible stall provided.

ST15

30 months

11.10

Drinking Fountain: 1st Floor.  The drinking fountain is inaccessible because its spout is 45 inches high.

DF6

24 months

11.11

Stairs: Leading to Gymnasium (Two Sets of Stairs)

   

11.11.a 

 

The stairs have a number of inaccessible features and are not accessible to people with disabilities.

AR10

30 months

11.11.b 

 

The route by the stairs is inaccessible because a cane detectable barrier is not provided under the stairs.

AR7

24 months

11.12

Gymnasium.  The gymnasium, containing approximately 480 seats, is inaccessible because it has bleacher style fixed seating and wheelchair seating areas are not provided.  A total of 6 wheelchair seating areas is required.

AA6

30 months

11.13

Women’s Gym Locker Room: Ground Level

   

11.13.a 

 

The sign is not mounted on the latch side of the door and does not have raised or Braille characters.

TR20

24 months

11.13.b 

The locker room is inaccessible because the opening width of both entrance doors is 29 inches, and the outer door requires 6 pounds of force to open and has a 2 inch high threshold.

D18

30 months

11.13.c 

 

No accessible mirror has been provided.

TR14

12 months

11.13.d 

 

The paper towel dispenser is inaccessible because the controls are mounted 56 inches high.

TR5

12 months

11.13.e 

The lavatory is inaccessible because the bottom of the apron is 27½ inches high, the hot water pipes are not insulated or otherwise configured to protect against contact, and the faucet requires tight grasping or twisting of the wrist to operate.

TR9

30 months

11.13.f 

 

There is no accessible toilet stall provided.

ST15

30 months

11.13.g 

 

There is no accessible shower provided.

B8

30 months

11.13.h 

 

No accessible towel hook has been provided.

TR1

12 months

11.13.i 

 

The towel hooks protrude into the walkway and would not be detectable to a blind person using a cane

AR8

12 months

11.13.j 

 

There is no accessible locker provided.

LR3

30 months

11.14

Men’s Gym Locker Room: Ground Level

   

11.14.a 

 

The sign is not mounted on the latch side of the door and does not have raised or Braille characters.

TR20

24 months

11.14.b 

 

The locker room is inaccessible because the opening width of both entrance doors is 29½ inches.

D25

30 months

11.14.c 

 

The outer door to the locker is inaccessible because there is a 2 inch high threshold.

D23

24 months

11.14.d 

 

The soap dispenser is inaccessible because the controls are mounted 56 inches high.

TR5

12 months

11.14.e 

The lavatory is inaccessible because the bottom of the apron is 27½ inches high, the hot water pipes are not insulated or otherwise configured to protect against contact, and the faucet requires tight grasping or twisting of the wrist to operate.

TR9

30 months

11.14.f 

 

The urinals are inaccessible because they are mounted with the rims 26 inches high.

TR20

24 months

11.14.g 

 

There is no accessible toilet stall provided.

ST15

30 months

11.14.h 

 

There is no accessible shower provided.

B8

30 months

11.14.i 

 

There is no accessible locker provided.

LR3

30 months

11.15

Drinking Fountain: Gymnasium Area.  The drinking fountain is inaccessible because its spout is 43 inches high.

DF6

24 months

12 

GRANT PARK SWIMMING POOL, located at 25 Park Ave, SE

   

12.1

Parking Lot. The parking lot, with a total of approximately 20 parking spaces, has no parking spaces provided for people with disabilities.  This lot requires 1 van accessible parking space.

P3

24 months

12.2

Accessible Route: From Parking Lot to Rear Entrance.  The route is inaccessible because there is a ½ inch unbeveled change in level at the gate.

AR1

24 months

12.3

Men’s Locker Room

   

12.3.a 

The locker room sign is mounted more than 60 inches high and has no raised or Braille characters.

TR18

24 months

12.3.b 

The door to the locker room is inaccessible because there is a 3¾ inch high threshold.

D23

24 months

12.3.c 

No accessible mirror has been provided.

TR14

12 months

12.3.d 

The lavatory is inaccessible because the faucet requires tight grasping or twisting of the wrist to operate.

TR10

24 months

12.3.e 

The designated accessible toilet stall is incorrectly configured as an ambulatory stall, and there is no standard accessible stall provided.

ST15

30 months

12.3.f

There is no accessible shower provided.

B8

30 months

12.3.g 

The benches are less than 24 inches wide and are not attached to the wall.

LR1

30 months

12.4

Women’s Locker Room

   

12.4.a 

The locker room sign is not mounted in the proper position and has no raised or Braille characters.

TR18

24 months

12.4.b 

The door to the locker room is inaccessible because the threshold is more than ½ inch high.

D23

24 months

12.4.c 

No accessible mirror has been provided.

TR14

12 months

12.4.d 

The sanitary napkin dispenser is inaccessible because the controls are mounted 57 inches high.

TR5

12 months

12.4.e 

The lavatory is inaccessible because the bottom edge of the apron is 24½ inches high, and the faucet requires twisting to operate.

TR9

24 months

12.4.f

The designated accessible toilet stall is incorrectly configured as an ambulatory stall, and there is no standard accessible stall provided.

ST15

30 months

12.4.g 

There is no accessible shower provided.

B8

30 months

12.4.h 

The benches are less than 24 inches wide and are not attached to the wall.

LR1

30 months

12.5

Picnic Tables.  The picnic tables at the pool area are inaccessible because none provide adequate knee space.

PD6

30 months

12.6

Accessible Route: To Pools

   

12.6.a 

The route from the lockers and picnic area to the pools is inaccessible because it slopes 6.6% and has no ramp features.

R3

30 months

12.6.b 

The stairs to the diving pool are inaccessible because they lack handrails

AR10

24 months

13 

BROWNWOOD RECREATION CENTER, located at 602 Brownwood Ave, SE

   

13.1

Parking Lot.  The parking lot, with a total of 15 parking spaces, has no van accessible parking space provided.  This lot requires 1 van accessible parking space.

P3

24 months

13.2

Exterior Accessible Route.  There is no accessible route provided from the parking lot to the tennis, basketball, or volleyball courts.

AR1

30 months

13.3

Main Entrance.  The door is inaccessible because there is a 1½ inch high threshold.

D23

24 months

13.4

Interior Room Signage.  Although room signage is provided, many of the signs are not mounted on the latch sides of the doors.

D26

24 months

13.5

Alarms.  Although the facility contains an emergency alarm system, the alarm system is inaccessible because visual alarms are not provided in all required locations.

AL1

30 months

13.6

Main Recreation Room

   

13.6.a 

The kitchen counter protrudes into the walkway and is not detectable to blind persons using a cane.

AR8

24 months

13.6.b 

The fire extinguisher protrudes into the walkway and is not detectable to blind persons using a cane.

AR8

12 months

13.6.c 

No accessible coat hook has been provided.

TR1

12 months

13.6.d 

The pool sticks are inaccessible because they are mounted 55½ inches high.

TR5

12 months

13.7

Picnic Tables in Pavilion.  The picnic tables are inaccessible because none provide the required knee space.

PD6

30 months

13.8

Ramp: Behind Recreation Center.  The ramp is inaccessible because it slopes more than 8.33%, and the handrails are 41 inches high and lack extensions at the bottom.

R5

30 months

13.9

Computer Room.  The pull side of the door, which can be accessed from the latch side of the door, is inaccessible because it has only 7 inches of clear width on the latch side.

D10

30 months

13.10

Drinking Fountain: Near Toilet Rooms

   

13.10.a 

Although an accessible drinking fountain is provided, there is no drinking fountain provided for people who have difficulty bending or stooping.

DF3

30 months

13.10.b 

 

The drinking fountain protrudes into the walkway and is not detectable to blind persons using a cane.

AR8

12 months

13.11

Women’s Toilet Room With Stalls

   

13.11.a 

 

The door is inaccessible because it requires 11 pounds of force to open.

D2

12 months

13.11.b 

 

Although an audible alarm is provided in this facility, there is no visual alarm appliance in the toilet room.

TR21

30 months

13.11.c 

The paper towel dispenser is inaccessible because the controls are mounted 50 inches high over an obstruction.

TR4

12 months

13.11.d 

 

The air dryer protrudes into the walkway and is not detectable to blind persons using a cane.

AR8

12 months

13.11.e 

 

The soap dispenser is inaccessible because it requires 13 pounds of force to operate.

TR3

12 months

13.11.f

The designated accessible stall is incorrectly configured as an ambulatory stall, and there is no standard accessible stall provided.

ST15

30 months

13.12

Men’s Toilet Room With Stalls

   

13.12.a 

 

The door is inaccessible because it requires 10 pounds of force to open.

D2

12 months

13.12.b 

 

Although an audible alarm is provided in this facility, there is no visual alarm appliance in the toilet room.

TR21

30 months

13.12.c 

 

The soap dispenser is inaccessible because the controls are mounted 56 inches high over an obstruction.

TR4

12 months

13.12.d 

 

The urinal is inaccessible because the rim is 24 inches high and the flush control is 49½ inches high.

TR20

30 months

13.12.e 

 

The air dryer protrudes into the walkway and is not detectable to blind persons using a cane.

AR8

12 months

13.12.f

The designated accessible stall is incorrectly configured as an ambulatory stall, and there is no standard accessible stall provided.

ST15

30 months

13.12.g 

 

There is no accessible locker provided.

LR3

30 months

13.13

Assembly Area: Weight Training Room.  The weight lifting equipment at the entrance door protrudes into the walkway and is not detectable to blind persons using a cane.

AR8

12 months

14 

BESSIE BRANHAM RECREATION CENTER, located at 2051 Brownwood Avenue, SE

   

14.1

Parking Lot.  The parking lot, with a total of 25 parking spaces, has no van accessible parking space, and the designated accessible parking spaces are not level.  This lot requires 1 van accessible parking space.

P3

30 months

14.2

Accessible Route: From Parking Lot To Main Entrance.  The route is inaccessible because the flared sides on the curb cut are too steep.

AR5

30 months

14.3

Arts and Crafts Room.  The door is inaccessible because it requires 10 pounds of force to open.

D2

12 months

14.4

Community Room.  The door is inaccessible because it requires 10 pounds of force to open.

D2

12 months

14.5

Men’s and Women’s Toilet Rooms: Old Section.  The toilet rooms have a number of inaccessible features and are not accessible to people with disabilities.

ST14

30 months

15 

BITSY GRANT CENTER, located at 2125 Northside Dr., NW

   

15.1

Accessible Route: to Clubhouse Entrance.  The route from the parking area to the clubhouse is inaccessible because the curb ramp has flared sides that slope up to 23.1%.

AR5

30 months

15.2

Pro’s Office:  Clubhouse.  The door to the Pro’s office is inaccessible because it has an opening width of 29 inches.

D25

30 months

15.3

Ramp: to Clubhouse Exterior Viewing Deck.  The ramp is inaccessible because it lacks edge protection and handrails.

R5

30 months

15.4

Exterior Entrance and Doors: Clubhouse

   

15.4.a 

The building does not have directional signage posted at inaccessible entrances and does not have the International Symbol of Accessibility posted at accessible entrances.

D16

12 months

15.4.b 

The double-leaf clubhouse entrance door is inaccessible because each leaf is 27½ inches wide.

D24

30 months

15.5

Interior Clubhouse Signage.  There is no signage directing people with disabilities to the accessible toilet room and shower.

TR16

24 months

15.6

Unisex Single-User Toilet Room and Shower:  Clubhouse

   

15.6.a 

The door is inaccessible because it requires 10 pounds of force to open.

D2

12 months

15.6.b 

The light switch is inaccessible because it is mounted 57 inches high.

TR5

12 months

15.6.c 

The toilet is inaccessible because the flush control is on the closed side.

SU1

24 months

15.6.d 

The rear grab bar at the toilet is inaccessible because it is 30 inches long.

SU3

24 months

15.6.e 

The shower is inaccessible because the clear floor space outside the shower is 36 inches wide, the spray unit hose is 57 inches long, and there is a 1½ inch high curb at the entrance of the stall.

B8

30 months

15.7

Clubhouse Lower Level.  There is no access to the lower level of the facility for people with mobility impairments.

AR9

30 months

15.8

Exterior Drinking Fountain:  By Hard Tennis Courts.  The drinking fountain protrudes into the walkway and is not detectable to blind persons using a cane.

AR8

24 months

15.9

Exterior Accessible Routes: To Tennis Courts

   

15.9.a 

The route to the clay courts is inaccessible because there is a 1 inch change in level on the sidewalk.

AR1

24 months

15.9.b 

The route to the clay courts is inaccessible because the built-up curb ramp at the courts slopes 13.5%.

AR5

30 months

15.9.c 

The route to the hard courts is inaccessible because the built-up curb ramps slope 17.8% at the first set of courts and 20.5% at the second set of courts.

AR5

30 months

15.10

Parking: By Hard Tennis Courts.  The parking lot, with a total of 104 parking spaces, has two spaces designated as reserved for people with disabilities.  This lot requires 1 van accessible space and 4 standard accessible spaces.

P3

30 months

16 

COLLIER PARK AND RECREATION CENTER, located at 3691 Collier Drive, NW

   

16.1

Parking Lot.  The parking lot, with a total of 38 parking spaces, has two designated accessible spaces with no access aisles, and no vertical signage, and one of the designated accessible spaces is not level.  This lot requires 1 van accessible space and 1 standard accessible space.

P3

30 months

16.2

Accessible Route: From Parking Lot to Entrance.  The route is inaccessible because the slope near the entrance is 10.5%.

AR1

30 months

16.3

Men’s Toilet Room With Stalls

   

16.3.a 

The door is inaccessible because it requires 12 pounds of force to open.

D2

12 months

16.3.b 

The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact.

TR12

24 months

16.3.c 

The lavatory is inaccessible because it has twist-type faucets.

TR10

24 months

16.3.d 

The urinal is inaccessible because the rim is 23 inches high and the flush is 51 inches high.

TR20

30 months

16.3.e 

The designated accessible stall is incorrectly configured as an ambulatory stall, and there is no standard accessible stall provided.

ST15

30 months

16.4

Women’s Toilet Room With Stalls

   

16.4.a 

The door is inaccessible because it requires 14 pounds of force to open.

D2

12 months

16.4.b 

The air dryer protrudes into the walkway and is not detectable to blind persons using a cane.

AR8

12 months

16.4.c 

The designated accessible stall is incorrectly configured as an ambulatory stall, and there is no standard accessible stall provided.

ST15

30 months

16.5

Recreation Room.  The door is inaccessible because it requires 10 pounds of force to open.

D2

12 months

16.6

Exterior Accessible Route

   

16.6.a 

The route from the parking lot to the sidewalk is inaccessible because the slope of the curb ramp is 9.1%, the slope of the flared sides is 24%, and there is a 2 inch change in level at the bottom of the curb ramp.

AR5

30 months

16.6.b 

The sidewalk to the play area is inaccessible because the slope is between 6.1% and 7.4%, and there are no ramp features.

R3

30 months

16.6.c 

The play area is inaccessible because the play equipment is blocked by wooden and rubber barriers, and there is no stable, firm, and slip resistant route.

AR1

30 months

16.6.d 

The Life Trail and the routes to the volleyball court and the ball fields are inaccessible because the sidewalks slope up to 14.5%.

AR1

30 months

16.7

Exterior Drinking Fountains.  The drinking fountains are operated by foot pedals and are not accessible to people with disabilities.

DF2

30 months

17 

ZABAN RECREATION CENTER, located at 241 Daniel Avenue, SE

   

17.1

Parking Lot.  The parking lot, with a total of 65 parking spaces, has no designated accessible parking spaces.  This lot requires 1 van accessible space and 2 standard accessible spaces.

P3

30 months

17.2

Exterior Accessible Routes

   

17.2.a 

The routes throughout the park, including the route from the parking lot to the recreation center, are inaccessible because they are covered in gravel and wood chips.

AR1

30 months

17.2.b 

The sidewalk to the main entrance is inaccessible because the running slope is 10.9% and the cross-slope is 4.3%.

AR1

30 months

17.3

Recreation Center Main Entrance.  The exterior ramp is inaccessible because it does not have accessible handrails.

R4

30 months

17.4

Drinking Fountain: Near Toilet Rooms.  Although an accessible drinking fountain is provided, there is no drinking fountain provided for people who have difficulty bending or stooping

DF3

30 months

17.5

Men’s Toilet Room With Stalls

   

17.5.a 

The door is inaccessible because it requires 12 pounds of force to open.

D2

30 months

17.5.b 

The toilet room is inaccessible because there is insufficient turning space provided within the room.

TR19

30 months

17.5.c 

The urinal is inaccessible because the width of the clear floor space is only 28 inches.

TR20

30 months

17.5.d 

The toilet stall is incorrectly configured as an ambulatory stall, and there is no standard accessible stall provided.

ST15

30 months

17.6

Women’s Toilet Room With Stalls

 

30 months

17.6.a 

The door is inaccessible because it requires 12 pounds of force to open.

D2

30 months

17.6.b 

The toilet room is inaccessible because there is insufficient turning space provided within the room.

TR19

30 months

17.6.c 

The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact.

TR12

30 months

17.6.d 

The toilet stall is incorrectly configured as an ambulatory stall, and there is no standard accessible stall provided.

ST15

30 months

17.7

Interior Ramp: Down to Exercise/Storage Room  The ramp is inaccessible because the inside handrail is not continuous and the ramp is covered in stored furniture and other items.

R3

30 months

18 

ATLANTA POLICE ZONE 3, located at 880 Cherokee Avenue

   

18.1

Accessible Route: Curb Ramp to Main Exterior Door.  The route is inaccessible because the short ramp has a 2 inch step at the bottom and a ¾ inch step at the top.

AR1

30 months

18.2

Main Entrance.  The pull side of the main entrance door, which is accessed through a front approach, is inaccessible because it has only 3 inches of maneuvering space on the latch side.

D6

30 months

18.3

Unisex Single-User Toilet Room: Main Lobby

   

18.3.a 

The door is inaccessible because it requires 20 pounds of force to open.

D2

12 months

18.3.b 

The toilet room is inaccessible because the door has knob hardware.

D1

24 months

18.3.c 

The toilet is inaccessible because the centerline is 16 inches from the side wall.

SU15

30 months

18.4

2nd  Floor.  There is no access to the upper level of the facility for people with mobility impairments.

AR9

30 months

18.5

Drinking Fountain: Lower Level.  Although an accessible drinking fountain is provided, there is no drinking fountain provided for people who have difficulty bending or stooping

DF3

30 months

18.6

Women’s Toilet Room With Stalls: Lower Level

   

18.6.a 

The toilet room sign is mounted on the door and has no raised or Braille characters.

TR18

24 months

18.6.b 

The door is inaccessible because it requires 6 pounds of force to open.

D2

12 months

18.6.c 

The pull side of the door to the toilet room, which is accessed through a front approach, is inaccessible because it has only 17 inches of maneuvering space on the latch side.

D6

30 months

18.6.d 

The toilet room door swings into the required clear floor space at the lavatory.

TR6

30 months

18.6.e 

Although an audible alarm is provided in this facility, there is no visual alarm appliance in the toilet room.

TR21

30 months

18.6.f

The designated accessible toilet is inaccessible because the stall is 45 inches wide.

ST16

30 months

18.6.g 

The designated accessible toilet is inaccessible because its centerline is 14 inches from the side wall.

ST17

30 months

18.6.h 

The designated accessible toilet is inaccessible because the flush control is on the closed side.

ST2

30 months

18.6.i

No accessible coat hook has been provided.

TR1

12 months

18.7

Men’s Toilet Room With Stalls: Lower Level

   

18.7.a 

The toilet room sign is mounted on the door and has no raised or Braille characters.

TR18

24 months

18.7.b 

The door is inaccessible because it requires 6 pounds of force to open.

D2

12 months

18.7.c 

Although an audible alarm is provided in this facility, there is no visual alarm appliance in the toilet room.

TR21

30 months

18.7.d 

The urinal is inaccessible because the rim is 23 inches high and the flush is 51 inches high.

TR20

30 months

18.7.e 

The designated accessible stall is incorrectly configured as an ambulatory stall, and there is no standard accessible stall provided.

ST15

30 months

19 

ATLANTA POLICE ZONE 4, located at 1125 Cascade Circle

   

19.1

Exterior Accessible Route: From Street Parking to Entrance.  The route is inaccessible because the it slopes between 5.6% and 7.1% and has no ramp features.

R3

30 months

19.2

Interior Accessible Route: From Main Lobby to Toilet Rooms.  The office doors are inaccessible because knob hardware is used.

D1

24 months

19.3

Men’s Toilet Room With Stalls

   

19.3.a 

The toilet room sign is mounted on the door and lacks raised and Braille characters.

TR18

24 months

19.3.b 

The door is inaccessible because it requires 9 pounds of force to open.

D2

12 months

19.3.c 

The pull side of the door, which is accessed through a front approach, is inaccessible because it has only 2½ inches of maneuvering space on the latch side.

D6

30 months

19.3.d 

The toilet room door swings into the required clear floor space at the lavatory.

TR6

30 months

19.3.e 

Although an audible alarm is provided in this facility, there is no visual alarm appliance in the toilet room.

TR21

30 months

19.3.f

No accessible mirror has been provided.

TR14

12 months

19.3.g 

The toilet room is inaccessible because there is insufficient turning space provided within the room.

TR19

30 months

19.3.h 

The soap dispenser is inaccessible because it is mounted with the controls 55 inches high over the lavatory.

TR4

12 months

19.3.i

The lavatory is inaccessible because the rim or counter is 35½ inches high to the top.

TR11

24 months

19.3.j

The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact.

TR12

24 months

19.3.k 

The urinal is inaccessible because the rim is 24 inches high and the flush control is 48 inches high.

TR20

30 months

19.3.l

The designated accessible stall is incorrectly configured as an ambulatory stall, and there is no standard accessible stall provided.

ST15

30 months

19.4

Women’s Toilet Room With Stalls

   

19.4.a 

The toilet room sign is mounted on the door and lacks raised and Braille characters.

TR18

24 months

19.4.b 

The door is inaccessible because it requires 9 pounds of force to open.

D2

12 months

19.4.c 

The pull side of the door, which is accessed through a front approach, is inaccessible because it has only 7 inches of maneuvering space on the latch side.

D6

30 months

19.4.d 

The toilet room door swings into the required clear floor space at the lavatory.

TR6

30 months

19.4.e 

Although an audible alarm is provided in this facility, there is no visual alarm appliance in the toilet room.

TR21

30 months

19.4.f

No accessible mirror has been provided.

TR14

12 months

19.4.g 

The toilet room is inaccessible because there is insufficient turning space provided within the room.

TR19

30 months

19.4.h 

The seat cover dispenser is inaccessible because it is mounted with the controls 58 inches high.

TR5

12 months

19.4.i

The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact.

TR12

24 months

19.4.j

The urinal is inaccessible because the rim is 24 inches high and the flush control is 48 inches high.

TR20

30 months

19.4.k 

The designated accessible stall is incorrectly configured as an ambulatory stall, and there is no standard accessible stall provided.

ST15

30 months

20 

ATLANTA FIRE STATION 15, located at 170 10th Street, NE

   

20.1

Unisex Single-User Toilet Room

   

20.1.a 

The toilet room sign is mounted on the door and has no raised or Braille characters.

TR18

24 months

20.1.b 

The door is inaccessible because it requires 10 pounds of force to open.

D2

12 months

20.1.c 

Although an audible alarm is provided in this facility, there is no visual alarm appliance in the toilet room.

TR21

30 months

20.1.d 

The lavatory is inaccessible because the hot water and drain pipes are not insulated or otherwise configured to protect against contact.

TR12

24 months

20.1.e 

The toilet is inaccessible because the top of the seat is 16 inches high.

SU18

30 months

20.1.f

The toilet is inaccessible because the centerline is 27 inches from the side wall.

SU15

30 months

20.1.g 

The toilet is inaccessible because the rear grab bar is 24 inches long and it is mounted 14½ inches from the side wall.

SU3

24 months

21 

ATLANTA FIRE STATION 17, located at 1489 Ralph David Abernathy Boulevard, SW

   

21.1

Parking Lot.  The parking lot, with a total of 4 parking spaces, has no designated accessible parking space.  This lot requires 1 van accessible space.

P3

24 months

21.2

Accessible Route: From Street to Main Entrance.  The route is inaccessible because the slope of the walkway is 13%.

AR1

30 months

21.3

Unisex Single-User Toilet Room: 1st Floor

   

21.3.a 

The toilet room sign is mounted on the door and has no raised or Braille characters.

TR18

24 months

21.3.b 

Although an audible alarm is provided in this facility, there is no visual alarm appliance in the toilet room.

TR21

30 months

21.3.c 

The lavatory is inaccessible because the rim or counter is 26 inches high to the bottom.

TR11

24 months

21.3.d 

The lavatory is inaccessible because the hot water and drain pipes are not insulated or otherwise configured to protect against contact.

TR12

24 months

21.3.e 

The toilet is inaccessible because the flush control is on the closed side.

SU1

24 months

21.3.f

The toilet is inaccessible because the side grab bar is mounted with the far end 50½ inches from the rear wall.

SU6

12 months

22 

ATLANTA FIRE STATION 35, located at 2150 East Non-Licensed Vehicle Road

   

22.1

Parking Lot.  The parking lot, with 25 total parking spaces, is inaccessible because it has no space designated as van accessible.  This lot requires 1 van accessible space.

P3

24 months

22.2

Exterior Accessible Route: From Parking Lot to Entrance

   

22.2.a 

The route is inaccessible because the width of the walkway narrows to 21 inches at the pipes and to 22½ inches at the barbeque grill.

AR3

30 months

22.2.b 

The shelf of the barbeque grill protrudes into the walkway and is not detectable to blind persons using a cane.

AR8

12 months

22.3

Interior Accessible Route: To Blood Pressure Screening Room 127. The route from the entrance to room 127 is inaccessible because it narrows to 22 inches wide at the sofa.

AR3

12 months

22.4

Blood Pressure Screening Room: 127

   

22.4.a 

The signage provided has no raised or Braille characters.

D26

24 months

22.4.b 

The route inside the room is inaccessible because it is only 30 inches wide between the chair and the open door.

AR3

12 months

22.5

Unisex Toilet Room With Stalls: 124

   

22.5.a 

The toilet room sign has no raised or Braille characters.

TR18

24 months

22.5.b 

The door is inaccessible because it requires 7 pounds of force to open.

D2

12 months

22.5.c 

The urinal is inaccessible because the rim is 18 inches high and the flush control is 46 inches high.

TR20

30 months

22.5.d 

No accessible coat hook has been provided.

TR1

12 months

22.5.e 

The designated accessible toilet is inaccessible because the rear grab bar is mounted 7 inches from the near side wall.

SU3

12 months

23 

DUNBAR NEIGHBORHOOD FACILITY, located at 477 Windsor Street, SW

   

23.1

Parking Lot.  The parking lot, with a total of 106 parking spaces, has only 4 designated accessible parking spaces, the designated accessible parking spaces have no vertical signage and no access aisles, and one of the designated accessible spaces has a cross slope of 3.4%.  This lot requires 1 van accessible space and 4 standard accessible spaces.

P3

30 months

23.2

Accessible Route: 2nd Floor.  The defibrillator protrudes into the walkway and is not detectable to blind persons using a cane.

AR8

12 months

23.3

Drinking Fountains: 2nd Floor

   

23.3.a 

The drinking fountain is inaccessible because the control requires 15 pounds of force to operate.

DF2

12 months

23.3.b 

The drinking fountain protrudes into the walkway and is not detectable to blind persons using a cane.

AR8

12 months

23.4

Women’s Toilet Room With Stalls: 2nd Floor

   

23.4.a 

The toilet room sign is mounted above the door and has no raised or Braille characters.

TR18

24 months

23.4.b 

The door is inaccessible because it requires 10 pounds of force to open.

D2

12 months

23.4.c 

The pull side of the door, which is accessed through a front approach, is inaccessible because it has only 12 inches of clear space on the latch side.

D6

30 months

23.4.d 

No accessible mirror has been provided.

TR14

12 months

23.4.e 

The air dryer protrudes into the walkway and is not detectable to blind persons using a cane.

AR8

12 months

23.4.f

The designated accessible stall is incorrectly configured as an ambulatory stall, and there is no standard accessible stall provided.

ST15

30 months

23.5

Men’s Toilet Room With Stalls: 2nd Floor

   

23.5.a 

The toilet room sign is mounted above the door and has no raised or Braille characters.

TR18

24 months

23.5.b 

The door is inaccessible because it requires 11 pounds of force to open.

D2

12 months

23.5.c 

No accessible mirror has been provided.

TR14

12 months

23.5.d 

The air dryer protrudes into the walkway and is not detectable to blind persons using a cane.

AR8

12 months

23.5.e 

The urinals are inaccessible because the rims are 21 inches high.

TR20

24 months

23.5.f

The designated accessible stall is incorrectly configured as an ambulatory stall, and there is no standard accessible stall provided.

ST15

30 months

23.6

Elevator.  The elevator is inaccessible because, although emergency communications are provided, the system does not work without voice communication.

E8

30 months

23.7

Offices and Rooms.  The doors are inaccessible because they require more than 5 pounds of force to open.

D2

12 months

24 

JOHN C. BIRDINE NEIGHBORHOOD FACILITY, located at 215 Lakewood Way, SW

   

24.1

Parking Lot.  The parking lot, with a total of 81 parking spaces, has no van accessible parking space, has no vertical signage designating spaces as accessible, and has designated accessible spaces and access aisles that slope between 5.2% and 7.7%.  This lot requires 1 van accessible space and 3 standard accessible spaces.

P3

30 months

24.2

Exterior Accessible Route: From Parking Lot to Main Entrance

   

24.2.a 

The route is inaccessible because the cross-slope of the walkway is 6.4%.

AR1

30 months

24.2.b 

The route is inaccessible because the slope of the curb ramp is 17.6%, and the flared sides are too steep.

AR5

30 months

24.3

Main Lobby: Counter.  The reception counter in the 1st  floor lobby is inaccessible because it is 42½ high.

C6

24 months

24.4

Women’s Toilet Room With Stalls: 1st Floor West Side

   

24.4.a 

The toilet room sign is mounted on the door and has no raised or Braille characters and no International Symbol of Accessibility.

TR17

24 months

24.4.b 

The door is inaccessible because it requires 17 pounds of force to open.

D2

12 months

24.4.c 

No accessible mirror has been provided.

TR14

12 months

24.4.d 

The air dryer protrudes into the walkway and is not detectable to blind persons using a cane.

AR8

12 months

24.4.e 

The designated accessible stall is incorrectly configured as an ambulatory stall, and there is no standard accessible stall provided.

ST15

30 months

24.5

Men’s Toilet Room With Stalls: 1st Floor West Side

   

24.5.a 

The toilet room sign is mounted on the door and has no raised or Braille characters and no International Symbol of Accessibility.

TR17

24 months

24.5.b 

The door is inaccessible because it requires 14 pounds of force to open.

D2

12 months

24.5.c 

No accessible mirror has been provided.

TR14

12 months

24.5.d 

The air dryer protrudes into the walkway and is not detectable to blind persons using a cane.

AR8

12 months

24.5.e 

The urinal is inaccessible because the rim is 23 inches high.

TR20

24 months

24.5.f

The designated accessible stall is incorrectly configured as an ambulatory stall, and there is no standard accessible stall provided.

ST15

30 months

24.6

Drinking Fountains: 1st Floor West Side.  The higher drinking fountain protrudes into the walkway and is not detectable to blind persons using a cane.

AR8

12 months

24.7

Women’s and Men’s Toilet Rooms with Stalls: 1st Floor East Side.  The toilet rooms lack accessible directional signage with the International Symbol of Accessibility indicating the location of the nearest accessible toilet room.

TR16

24 months

24.8

Interior Accessible Route: 1st Floor East Side.  The defibrillator protrudes into the walkway and is not detectable to blind persons using a cane.

AR8

12 months

24.9

Library.  The library is inaccessible because the automatic door opener requires 14 pounds of force to operate.

TR3

12 months

24.10

Women’s and Men’s Toilet Rooms with Stalls: 2nd Floor West Side:  The toilet rooms lack accessible directional signage with the International Symbol of Accessibility indicating the location of the nearest accessible toilet room. 

TR16

24 months

24.11

Drinking Fountains: 2nd Floor West Side.  The higher drinking fountain protrudes into the walkway and is not detectable to blind persons using a cane.

AR8

12 months

24.12

East Wing Counter.  The counter is inaccessible because it is 40 inches high.

C6

24 months

25 

MADDOX PARK, located at 1145 North Avenue, NW

   

25.1

Parking Lot.  The parking lot, with a total of 12 parking spaces, has no designated accessible parking spaces.  This lot requires 1 van accessible space.

P3

24 months

25.2

Exterior Accessible Routes

   

25.2.a 

There is no accessible route to the tennis court because there is no curb ramp from the road.

AR5

30 months

25.2.b 

The route to the pavilion is inaccessible because it has numerous stairs.

AR1

30 months

25.3

Picnic Tables.  There are no accessible picnic tables provided.

PD6

30 months

25.4

Locker Rooms.  The men’s and women’s locker rooms contain a number of inaccessible elements and are not accessible to people with disabilities.

LR4

30 months

26 

CHASTAIN ARTS CENTER, located at 135 W. Wieuca Road, NW

   

26.1

Parking.  The parking lot, with a total of 28 parking spaces, is inaccessible because the designated accessible spaces have no access aisles and no vertical signage.  This lot requires 1 van accessible space and 1 standard accessible space.

P3

24 months

26.2

Ramp to Entry

   

26.2.a 

The ramp is inaccessible because it has a lip at the top and the bottom 1 inch high.

AR1

30 months

26.2.b 

The ramp is inaccessible because it has insufficient landing at the bottom and at the change in direction, it slopes between 10.5% and 11.1%, it does not have adequate edge protection, and the handrails lack extensions.

R3

30 months

26.3

Curb Ramp.  The curb ramp is inaccessible because it has a slope of 9.6%.

AR5

24 months

26.4

Entrances.  The building does not have directional signage posted at inaccessible entrances and does not have the International Symbol of Accessibility posted at accessible entrances.

D16

24 months

26.5

Front Entrance

   

26.5.a 

The route from the entry ramp to the front door is inaccessible because it slopes 9.4% and has no handrails.

AR1

24 months

26.5.b 

The route to the front door is inaccessible because the ramp’s front edge has a 1 inch high step up onto it.

AR1

24 months

26.5.c 

The front door is inaccessible because there is a slope of 10.8% within the door’s required maneuvering clearance.

D13

24 months

26.6

Children’s Studio Entrance.  The ramp to the entrance is inaccessible because it slopes up to 16.8%, it does not have adequate edge protection, and the handrail is mounted 2 inches from the wall.

R3

24 months

26.7

Men’s Single-User Toilet Room:  Near Children’s Studio

   

26.7.a 

No accessible mirror has been provided.

TR14

12 months

26.7.b 

The lavatory is inaccessible because the hot water pipes are not fully insulated or otherwise configured to protect against contact.

TR12

24 months

26.7.c 

The toilet is inaccessible because its centerline is 19½ inches from the side wall.

SU15

30 months

26.7.d 

The side grab bar at the toilet is inaccessible because it is mounted 15 inches from the rear wall.

SU6

12 months

26.8

Women’s Single-User Toilet Room:  Near Children’s Studio

   

26.8.a 

No accessible mirror has been provided.

TR14

12 months

26.8.b 

The lavatory is inaccessible because the hot water pipes are not fully insulated or otherwise configured to protect against contact.

TR12

24 months

26.8.c 

The side grab bar at the toilet is inaccessible because it is mounted 15 inches from the rear wall.

SU6

12 months

26.9

Drinking Fountain:  Main Entry.  The drinking fountain is inaccessible because the spout is 41½ inches high, the water flow is 3 inches high, the water flows 4 inches from the front of the fountain, and the controls require 9 pounds of force to operate.

DF1

30 months

26.10

Interior Doors.  Many of the doors are inaccessible because knob hardware is used.

D1

24 months

26.11

Interior Accessible Route.  The suggestion box in the classroom hallway protrudes into the walkway and is not detectable to blind persons using a cane.

AR8

12 months

26.12

Inaccessible Toilet Rooms.  There is no signage directing people with disabilities to the accessible toilet rooms.

TR16

30 months

26.13

Pottery Studio:  Main Building

   

26.13.a 

 

No accessible coat hook has been provided.

TR1

12 months

26.13.b 

 

The fire extinguisher protrudes into the walkway and is not detectable to blind persons using a cane.

AR8

12 months

26.14

City Gallery:  Main Entrance.  The door is inaccessible because there is a 1½ inch high threshold.

D23

24 months

26.15

City Gallery:  Painting Studio.  The door is inaccessible because there is a 1½ inch high threshold.

D23

24 months

26.16

City Gallery:  Studio I and II.  The doors are inaccessible because knob hardware is used.

D1

24 months

26.17

City Gallery: Toilet Rooms.  The toilet rooms contain a number of inaccessible elements and are not accessible to people with disabilities, and there is no signage directing people with disabilities to the accessible toilet rooms.

TR16

30 months

26.18

City Gallery:  Drinking Fountain.

   

26.18.a 

 

The drinking fountain protrudes into the walkway and is not detectable to blind persons using a cane.

AR8

12 months

26.18.b 

Although an accessible drinking fountain is provided, there is no drinking fountain provided for people who have difficulty bending or stooping.

DF3

30 months