ATTACHMENT I: Modifications to Newly Constructed Facilities

Please Note:  Paragraph 42 of the Settlement Agreement requires that within three months of the effective date of this Agreement, the City provide signage as necessary to comply with 28 C.F.R. § 35.163(b), after having surveyed all facilities that are the subject of this Agreement for the purpose of identifying those that have multiple entrances not all of which are accessible.

In order to ensure that the following spaces and elements in City facilities for which construction was commenced after January 26, 1992, are readily accessible to and usable by persons with disabilities, the City will take the actions referenced by the alphanumeric code and described in detail in Attachment M to this Settlement Agreement.  Actions are to be completed before the end of the time specified in the Completion Date column.

Item #

Access Issue                                                                                                                       

Required Action

Completion Date

1

COAN PARK, located at 1530 Woodbine Avenue, SE

   

1.1      

Exterior Accessible Route.  The route from the parking lot to the park is inaccessible because the curb ramp has a cross slope of 3.3%, and there is a 1 inch change in level at the bottom of the curb ramp.

AR5

30 months

2         

MUNICIPAL COURT, located at 150 Garnett St, SW

   

2.1      

Exterior Accessible Route.  The route from on-street parking to the main entrance is inaccessible because the running slope is greater than 5% although it has no ramp features, and the cross-slope is greater than 2%.

AR1

30 months

2.2      

Main Entrance.  The main entrance is inaccessible because there is a 1 inch high threshold.

D22

30 months

2.3      

Interior Accessible Route: Lobby.  The route from the vestibule to the lobby is inaccessible because it narrows to 30 inches wide.

AR3

24 months

2.4      

Employee Parking.  The parking lot, with 25 total parking spaces, has no van accessible parking space and no vertical signage designating spaces as accessible.  This lot requires 1 van accessible space.

P3

24 months

2.5      

Interior Accessible Route: Side Security Entrance.  The route through the security scanner is inaccessible because it is only 29 inches wide.

AR3

24 months

2.6      

Judges's Parking: Basement.  The parking lot, with a total of 55 parking spaces, has only 2 designated accessible spaces, it has no van accessible space, and the vertical sign is mounted too low.  This lot requires 1 van accessible space and 2 standard accessible spaces.

P3

24 months

2.7      

Accessible Route:  Judge's Parking Entrance.  The door from the Judge's parking area is inaccessible because there is a 1 inch high threshold.

D22

24 months

2.8      

Interior Doors: General.  The doors throughout the facility are inaccessible because they require more than 5 pounds of force to open.

D2

12 months

2.9      

Toilet Rooms: General

   

2.9.a   

The lavatories throughout the facility are inaccessible because the rims or counters are between 34½ and 35 high to the top.

TR11

30 months

2.9.b   

The side grab bars at designated accessible toilets throughout the facility are inaccessible because they are obstructed by the toilet paper dispensers.

ST8

SU7

24 months

2.10    

Drinking Fountains: General.  The higher drinking fountains throughout the facility protrude into the walkway and are not detectable to blind persons using a cane.

AR8

24 months

2.11    

Interview Room 118.  The bench on the prisoner side obstructs the clear floor space at the window.

PJ7

24 months

2.12    

Drinking Fountain:  Holding Area.  Although an accessible drinking fountain is provided, there is no drinking fountain provided for people who have difficulty bending or stooping.

DF3

30 months

2.13    

Women's Employee Toilet Room With Stalls: First Floor

   

2.13.a 

The toilet room sign is mounted on the door and has no raised or Braille characters.

TR18

24 months

2.13.b 

The pull side of the door to the toilet room, which is accessed through a front approach, is inaccessible because it has only 11 inches of maneuvering space on the latch side.

D6

30 months

2.14    

Men's Employee Toilet Room With Stalls: First Floor.  The toilet room sign is mounted on the door and has no raised or Braille characters.

TR18

24 months

2.15    

Court Room 1A

   

2.15.a 

The court room sign is mounted on the door and lacks raised or Braille characters.

D26

24 months

2.15.b 

There is no signage informing the public of the availability of an assistive listening system.

AA3

24 months

2.16    

Court Room 1B

   

2.16.a 

The court room sign is mounted on the door and lacks raised or Braille characters.

D26

24 months

2.16.b 

There is no signage informing the public of the availability of an assistive listening system.

AA3

24 months

2.16.c 

The ramp to the court reporter's stand is inaccessible because the running slope is 9.7%.

R5

24 months

2.16.d 

The counsel's table in the court room is inaccessible because the bottom edge is 25 inches high.

T1

12 months

2.17    

Drinking Fountains: First Floor.  Although accessible drinking fountains are provided, there is no drinking fountain provided for people who have difficulty bending or stooping.

DF3

30 months

2.18    

Women's Public Toilet Rooms with Stalls: First Floor.  The tampon dispenser is inaccessible because it requires wrist-twisting to operate.

TR3

24 months

2.19    

Employee Single-User Toilet Room: Roll Call Room 186

   

2.19.a 

The pull side of the door to the toilet room, which is accessed from the latch side of the door, is inaccessible because it has only 39 inches of clear width.

D10

24 months

2.19.b 

Although an audible alarm is provided in this facility, there is no visual alarm appliance in the toilet room.

TR21

30 months

2.19.c 

No accessible mirror has been provided.

TR14

24 months

2.19.d 

The rear grab bar at the toilet is inaccessible because the soap dispenser interferes with its use.

SU4

24 months

2.20    

Closed Records Room 185

   

2.20.a 

The pull side of the door, which is accessed through a front approach, is inaccessible because it has only 10 inches of maneuvering space on the latch side.

D6

30 months

2.20.b 

The counter is inaccessible because it is 39 inches high.

C6

24 months

2.21    

Probation Services, Records Management, Warrant Services, Room 195A. The pull side of the door, which is accessed through a front approach, is inaccessible because it has only 15 inches of maneuvering space on the latch side.

D6

30 months

2.22    

Rosie Robinson, Captain, Court Detention Unit.  The route into Captain Robinson's office is inaccessible because it is only 27 inches wide.

AR3

24 months

2.23    

Interior Accessible Route First Floor: Near DIT Repair.  The defibrillator protrudes into the walkway and is not detectable to blind persons using a cane.

AR8

24 months

2.24    

Dining/Vending Room 276. The room sign is mounted on the hinge side of the door.

D26

12 months

2.25    

Telephone: Second Floor

   

2.25.a 

The pay telephone on the second floor is mounted with the coin slot 60 inches high, has a cord 28 inches long, and does not have volume control.

TT1

24 months

2.25.b 

The telephone protrudes into the walkway and is not detectable to blind persons using a cane.

AR8

24 months

2.26    

Men's Staff Toilet Room With Stalls: Second Floor.  The seat cover dispenser is inaccessible because the controls are mounted 58 inches high.

TR5

12 months

2.27    

Staff Break Room 293.  The pull side of the door, which is accessed from the latch side of the door, is inaccessible because it has 39 inches of maneuvering width.

D10

30 months

2.28    

Single-User Toilet Room Second Floor: Court Program Clerk

   

2.28.a 

No accessible mirror has been provided.

TR14

12 months

2.28.b 

The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact.

TR12

24 months

2.29    

Community Service Conference Room. The conference table is inaccessible because it is 24½ inches high to the bottom.

T1

24 months

2.30    

Court Room 3A

   

2.30.a 

The sign is mounted on the door and has no raised or Braille characters. 

D26

24 months

2.30.b 

There is no signage informing the public of the availability of an assistive listening system.

AA3

24 months

2.31    

Assembly Area Third Floor: Court Room 3B

   

2.31.a 

The sign is mounted above the door and has no raised or Braille characters.

D26

24 months

2.31.b 

There is no signage informing the public of the availability of an assistive listening system.

AA3

24 months

2.32    

Watershed Management Call Center: Fourth Floor. The ramp is inaccessible because the handrails do not have extensions parallel with the floor at the top and bottom.

R4

30 months

2.33    

Men's Employee Toilet Room With Stalls: Watershed Management Call Center

   

2.33.a 

The rear grab bar at the designated accessible toilet is inaccessible because it is mounted 7 inches from the side wall.

ST4

12 months

2.33.b 

The paper towel dispenser protrudes into the walkway and is not detectable to blind persons using a cane.

AR8

12 months

2.34    

Break Room Single-User Toilet Room: Watershed Management Call Center

   

2.34.a 

The lavatory is inaccessible because the apron is 28½ inches high to the bottom.

TR11

24 months

2.34.b 

The toilet is inaccessible because its centerline is 19 inches from the side wall.

SU15

30 months

2.34.c 

The toilet is inaccessible because the flush control is on the closed side.

SU1

30 months

2.35    

Accessible Route: Fifth Floor Public Hallway.  The defibrillator protrudes into the walkway and is not detectable to blind persons using a cane.

AR8

12 months

2.36    

Men's Public Toilet Room With Stalls: Fifth Floor.  The designated accessible toilet is inaccessible because its centerline is 18½ inches from the side wall.

ST17

30 months

2.37    

Court Room 6A

   

2.37.a 

The sign is mounted above the door and has no raised or Braille characters. 

D26

24 months

2.37.b 

There is no signage informing the public of the availability of an assistive listening system.

AA3

24 months

2.38    

Jury Deliberation Single-User Toilet Room: Sixth Floor

   

2.38.a 

The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact.

TR12

24 months

2.38.b 

The toilet is inaccessible because its centerline is 17½ inches from the side wall.

SU15

24 months

2.39    

Staff Single-User Toilet Room: Sixth Floor

   

2.39.a 

The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact.

TR12

24 months

2.39.b 

The toilet is inaccessible because its centerline is 17½ inches from the side wall.

SU15

30 months

2.40    

Men's Public Toilet Room With Stalls Sixth Floor.  The toilet is inaccessible because its centerline is 17½ inches from the side wall.

ST17

30 months

2.41    

Women's Public Toilet Room With Stalls Sixth Floor.  The toilet is inaccessible because its centerline is 18½ inches from the side wall.

ST17

30 months

3         

ATLANTA POLICE DEPARTMENT ZONE 1, located at 2315 Donald Lee Hollowell Parkway

   

3.1      

Parking Lot

   

3.1.a   

The parking lot, with a total of 58 parking spaces, has only 2 spaces designated as reserved for people with disabilities, and neither of these spaces is designated as van accessible.  This lot requires 1 van accessible space and 2 standard accessible spaces.

P3

30 months

3.1.b   

The curb ramp from the parking area onto the sidewalk has flared sides that slope more than 10%.

AR5

30 months

3.2      

Single-User Toilet Room: Main Lobby

   

3.2.a   

The toilet room sign is mounted on the door.

TR18

12 months

3.2.b   

Although an audible alarm is provided in this facility, there is no visual alarm appliance in the toilet room.

TR21

30 months

3.2.c   

No accessible mirror has been provided.

TR14

12 months

3.2.d   

The lavatory is inaccessible because the apron is 27 inches high to the bottom.

TR11

24 months

3.2.e   

The toilet is inaccessible because its centerline is 17½ inches from the side wall.

SU15

30 months

3.2.f    

The toilet paper dispenser is inaccessible because it is mounted 44 inches from the rear wall.

SU17

12 months

3.2.g   

The side grab bar at the toilet is inaccessible because it is 36 inches long and it is mounted 15 inches from the rear wall.

SU6

12 months

3.2.h   

The rear grab bar at the toilet is inaccessible because it is 30 inches long.

SU3

12 months

3.3      

Men's Locker Room: First Floor

   

3.3.a   

The room sign is mounted on the door.

TR18

12 months

3.3.b   

The pull side of the door, which is accessed from the latch side of the door, is inaccessible because it has only 14 inches of clear space on the latch side.

D10

30 months

3.3.c   

No accessible mirror has been provided.

TR14

12 months

3.3.d   

The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact.

TR12

24 months

3.3.e   

The designated accessible toilet is inaccessible because its centerline is 17½ inches from the side wall.

ST17

30 months

3.3.f    

The designated accessible toilet is inaccessible because the flush control is on the closed side.

ST2

30 months

3.3.g   

The toilet paper dispenser is inaccessible because its mounted 43 inches from the rear wall.

ST19

12 months

3.3.h   

The rear grab bar at the designated accessible toilet is inaccessible because it is mounted 9 inches from the near side wall.

ST4

12 months

3.3.i    

The designated accessible shower is inaccessible because the stall dimensions are 36 inches by 34 inches, there is insufficient clear floor space outside the shower, the seat is mounted 21 inches high on the wall adjacent to the shower controls, and there are no grab bars.

B8

30 months

3.4      

Women's Locker Room: First Floor

   

3.4.a   

The room sign is mounted on the door.

TR18

12 months

3.4.b   

No accessible mirror has been provided.

TR14

12 months

3.4.c   

The designated accessible toilet is inaccessible because its centerline is 17½ inches from the side wall.

ST17

30 months

3.4.d   

The shower is inaccessible because the stall dimensions are 39 inches by 38 inches, there is no transfer seat, there are no grab bars, and there is insufficient clear floor space outside the shower

B8

30 months

3.5      

Men's Toilet Room With Stalls: Second Floor

   

3.5.a   

The room sign is mounted on the door.

TR18

12 months

3.5.b   

No accessible mirror has been provided.

TR14

12 months

3.5.c   

The urinal is inaccessible because the rim is 24 inches high.

TR20

30 months

3.5.d   

There is no accessible toilet stall provided.

ST15

30 months

3.6      

Women's Toilet Room With Stalls: Second Floor

   

3.6.a   

The room sign is mounted on the door.

TR18

12 months

3.6.b   

No accessible mirror has been provided.

TR14

12 months

3.6.c   

The lavatory is inaccessible because a table is blocking the clear floor space.

TR8

12 months

3.6.d   

There is no accessible toilet stall provided.

ST15

30 months

4         

ATLANTA POLICE DEPARTMENT ZONE 5, located at 398 Centennial Olympic Park Drive

   

4.1      

Accessible Route: From Parking Lot to Main Entrance.  The route is inaccessible because the slope of the curb ramp is 8.8% and the slopes of the flared sides are 21.1% and 26%.

AR5

30 months

4.2      

Drinking Fountains: By Lockers.  The higher drinking fountain protrudes into the walkway and is not detectable to blind persons using a cane.

AR8

12 months

4.3      

Women's Locker Room

   

4.3.a   

The sign is mounted 59 inches high.

TR18

12 months

4.3.b   

The door is inaccessible because it requires 10 pounds of force to open.

D2

12 months

4.3.c   

The toilet is inaccessible because its centerline is 19½ inches from the side wall.

ST17

30 months

4.3.d   

No accessible coat hook has been provided.

TR1

12 months

4.3.e   

The shower is inaccessible because the stall dimensions are 50 inches deep by 47 inches wide, the controls are 50 inches high, and the shower does not have grab bars on three walls.

B8

30 months

4.3.f    

The bench is 9½ inches wide and 20 inches above the finished floor and is not fixed to the wall along the bench's longer dimension.

LR1

30 months

4.3.g   

There is no accessible locker provided.

LR3

30 months

4.4      

Men's Locker Room

   

4.4.a   

The sign is mounted 59 inches high.

TR18

12 months

4.4.b   

The door is inaccessible because it requires 10 pounds of force to open.

D2

12 months

4.4.c   

The toilet is inaccessible because its centerline is 21½ inches from the side wall.

ST17

30 months

4.4.d   

The toilet is inaccessible because the flush control is on the closed side.

ST2

30 months

4.4.e   

No accessible coat hook has been provided.

TR1

12 months

4.4.f    

The shower is inaccessible because the stall dimensions are 50 inches deep by 48 inches wide, the controls are 50 inches high, and the shower does not have grab bars on three walls.

B8

30 months

4.4.g   

The bench is 9½ inches wide and 20 inches above the finished floor and is not fixed to the wall along the bench's longer dimension.

LR1

30 months

4.4.h   

There is no accessible locker provided.

LR3

30 months

4.5      

Front Desk.  The door is inaccessible because it requires 7 pounds of force to open.

D2

12 months

4.6      

Sergeant Butler's Office.  The route into Sergeant Butler's office is inaccessible because it is only 27½ inches wide.

AR3

24 months

5         

WASHINGTON PARK NATATORIUM, located at 102 Ollie St, NW

   

5.1      

Exterior Accessible Route.  The route from the parking lot to the sidewalk is inaccessible because the slope of the curb ramp is 9%.

AR5

30 months

5.2      

Drinking Fountains.  The drinking fountains on both floors protrude into the walkway and are not detectable to blind persons using a cane.

AR8

12 months

5.3      

Women's Toilet Room with Stalls: Upper Level

   

5.3.a   

The toilet room sign is mounted 56 inches high.

TR18

30 months

5.3.b   

The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact.

TR12

24 months

5.4      

Men's Toilet Room With Stalls: Upper Level

   

5.4.a   

The toilet room sign is mounted 56 inches high.

TR18

12 months

5.4.b   

The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact.

TR12

24 months

5.5      

Elevator.  The elevator is inaccessible because, although emergency communications are provided, the system does not operate without voice communication.

E8

30 months

5.6      

Men's Locker Room: Lower Level

   

5.6.a   

The locker room sign is mounted 57 inches high.

TR18

12 months

5.6.b   

The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact.

TR12

24 months

5.6.c   

The air dryers protrude into the walkway and are not detectable to blind persons using a cane.

AR8

12 months

5.6.d   

The designated accessible transfer shower is inaccessible because the stall is 39 inches by 47 inches, the seat does not extend the full depth of the stall, the shower spray unit cannot be fixed, and there is no shower head.

B8

30 months

5.6.e   

There is no accessible locker provided.

LR3

30 months

5.7      

Women's Locker Room: Lower Level

   

5.7.a   

The locker room sign is mounted 57 inches high.

TR18

12 months

5.7.b   

The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact.

TR12

24 months

5.7.c   

The air dryers protrude into the walkway and are not detectable to blind persons using a cane.

AR8

12 months

5.7.d   

The designated accessible transfer shower is inaccessible because the stall is 39 inches by 47 inches and the seat does not extend the full depth of the stall.

B8

30 months

5.7.e   

There is no accessible locker provided.

LR3

30 months

5.8      

Pavilions.  The route to the pavilions is not firm, stable, or slip resistant and lacks a curb ramp.

AR1

30 months

6         

ATLANTA FIRE STATION 14, located at 1203 Lee Street SW

   

6.1      

Parking Lot.  The parking lot, with a total of 10 parking spaces, has no van accessible parking space, and the access aisle is 48 inches wide.  This lot requires 1 van accessible space.

P3

24 months

6.2      

Exterior Accessible Route: From Parking Lot to Main Entrance.  The route near the main entrance is inaccessible because it slopes 8.9%.

AR1

30 months

6.3      

Main Lobby.  The drinking fountains protrude into the walkway and are not detectable to blind persons using a cane.

AR8

12 months

6.4      

Men's Single-User Toilet Room: Lobby.  The toilet is inaccessible because its centerline is 17 inches from the side wall.

SU15

30 months

6.5      

Gear Room 108

   

6.5.a   

The door is inaccessible because it requires 6 pounds of force to open.

D2

12 months

6.5.b   

The room sign is mounted on the hinge side of the door.

D26

12 months

6.6      

Physical Training Room 110

   

6.6.a   

The door is inaccessible because it requires 7 pounds of force to open.

D2

12 months

6.6.b   

The room sign is mounted 61½ inches high.

D26

12 months

6.7      

Captain's Office.  The pull side of the door, which is accessed through a front approach, is inaccessible because it only has 12 inches of maneuvering space on the latch side.

D6

30 months

6.8      

Kitchen.  The door is inaccessible because it requires 8 pounds of force to open.

D2

12 months

6.9      

Dormitory

   

6.9.a   

The door is inaccessible because it requires 6 pounds of force to open.

D2

12 months

6.9.b   

The fire extinguisher protrudes into the walkway and is not detectable to blind persons using a cane.

AR8

12 months

6.10    

Women's Locker Room 119

   

6.10.a 

The locker room sign is mounted 55 inches high.

TR18

12 months

6.10.b 

The pull side of the door, which is accessed from the latch side of the door, is inaccessible because it has only 6½ inches of space on the latch side.

D10

30 months

6.10.c 

The locker room door swings into the required clear floor space at the lavatory.

TR6

30 months

6.10.d 

The paper towel dispenser is inaccessible because the controls are mounted 54 inches high over the bench.

TR4

12 months

6.10.e 

The designated accessible toilet is inaccessible because the clear floor space is 47 inches wide.

ST18

30 months

6.10.f  

The designated accessible toilet is inaccessible because the top of the seat is 16 inches high.

ST20

30 months

6.10.g 

The designated accessible toilet is inaccessible because its centerline is 22 inches from the side wall.

ST17

30 months

6.10.h 

The designated accessible toilet is inaccessible because the flush control is on the closed side.

ST2

30 months

6.10.i  

There are no grab bars provided at the designated accessible toilet.

ST11

30 months

6.10.j  

There is no accessible shower provided.

B8

30 months

6.10.k 

The bench in the dressing area is inaccessible because it is 24 inches long, is 9½ inches wide, and is not fixed to the wall.

LR1

30 months

6.10.l  

There is no accessible locker provided.

LR3

30 months

6.11    

Men's Locker Room

   

6.11.a 

The paper towel dispenser is inaccessible because the controls are mounted 54 inches high over the bench.

TR4

12 months

6.11.b 

The urinal is inaccessible because the rim is 24 inches high.

TR20

30 months

6.11.c 

The designated accessible toilet is inaccessible because the clear floor space is 47 inches wide.

ST18

30 months

6.11.d 

The designated accessible toilet is inaccessible because the top of the seat is 16 inches high.

ST20

30 months

6.11.e 

The designated accessible toilet is inaccessible because its centerline is 19 inches from the side wall.

ST17

30 months

6.11.f  

There are no grab bars provided at the designated accessible toilet.

ST11

30 months

6.11.g 

There is no accessible shower provided.

B8

30 months

6.11.h 

The bench in the dressing area is inaccessible because it is 9½ inches wide and is not fixed to the wall.

LR1

30 months

6.11.i  

There is no accessible locker provided.

LR3

30 months

7         

ATLANTA FIRE STATION 4, located at 309 Edgewood Avenue

   

7.1      

Parking Lot.  The parking lot, with a total of 8 parking spaces, has two designated accessible parking spaces with no vertical signage and with slopes between 6.4% and 7.9%.   This lot requires 1 van accessible space.

P3

30 months

7.2      

Exterior Accessible Route: From Parking Lot to Front Entrance.  The route is inaccessible because the slope of the curb ramp is 9.3% and the slope of the flared sides is between 20.9% and 23.9%.

AR5

30 months

7.3      

Interior Doors.  Many of the interior doors are inaccessible because they require more than 5 pounds of force to open.

D2

12 months

7.4      

Women's Single-User Toilet Room: Lobby

   

7.4.a   

The toilet is inaccessible because the centerline is 19 inches from the side wall.

SU15

30 months

7.4.b   

The toilet paper is not mounted in an accessible location.

SU17

12 months

7.5      

Men's Single-User Toilet Room: Lobby.  The toilet is inaccessible because the centerline is 19½ inches from the side wall.

SU15

30 months

7.6      

Community Room 103.  The push side of the door, which is accessed through a front approach and which has both a closer and a latch, is inaccessible because it has only 2 inches of clear space on the latch side.

D7

30 months

7.7      

Watch Officer Room 121.  The room sign is mounted 71 inches high.

D26

12 months

7.8      

Apparatus Room 129.  The room sign is mounted 70 inches high.

D26

12 months

7.9      

Women's Locker Room 105

   

7.9.a   

The room sign is mounted 63 inches high.

TR18

12 months

7.9.b   

The lavatories are inaccessible because they do not have adequate knee clearance.

TR11

30 months

7.9.c   

There is no accessible toilet stall provided.

ST15

30 months

7.9.d   

There is no accessible shower stall provided.

B8

30 months

7.9.e   

The bench in the dressing area is inaccessible because it is 9½ inches wide and is not fixed to the wall.

LR1

30 months

7.10    

Men's Locker Room 109

   

7.10.a 

The room sign is mounted 62½ inches high.

TR18

12 months

7.10.b 

No accessible mirror has been provided.

TR14

12 months

7.10.c 

The lavatories are inaccessible because they do not have adequate knee clearance.

TR11

30 months

7.10.d 

The urinal is inaccessible because the rim is 24 inches high.

TR20

30 months

7.10.e 

There is no accessible toilet stall provided.

ST15

30 months

7.10.f  

There is no accessible shower stall provided.

B8

30 months

7.10.g 

The bench in the dressing area is inaccessible because it is 9½ inches wide and is not fixed to the wall.

LR1

30 months

7.11    

Dormitory Room 107.  The room sign is mounted 68 inches high.

D26

12 months

8         

ADAMSVILLE RECREATION CENTER, located at 3201 MLK Jr. Drive, SW

   

8.1      

Exterior Accessible Route: From Parking Lot to Main Entrance.  The curb ramps have flared sides that slope more than 10%.

AR5

30 months

8.2      

Interior Accessible Route: Beneath Stairs.  The route is inaccessible because there are less than 80 inches of head room provided.

AR7

24 months

8.3      

Women's Toilet Room With Stalls: Second Floor

   

8.3.a   

The door is inaccessible because it requires 6 pounds of force to open.

D2

12 months

8.3.b   

No accessible mirror has been provided

TR14

12 months

8.3.c   

The air dryer protrudes into the walkway and is not detectable to blind persons using a cane.

AR8

12 months

8.3.d   

The designated accessible toilet is inaccessible because the centerline is 17 inches from the side partition.

ST17

30 months

8.3.e               

Although there are 6 toilet stalls, there is no ambulatory stall provided.

ST1

30 months

8.4      

Men's Toilet Room With Stalls: Second Floor

   

8.4.a   

The door is inaccessible because it requires 6 pounds of force to open.

D2

12 months

8.4.b   

No accessible mirror has been provided

TR14

12 months

8.4.c   

The air dryer protrudes into the walkway and is not detectable to blind persons using a cane.

AR8

12 months

8.4.d   

The designated accessible urinal is inaccessible because the rim is 18 inches high and the flush control is 47 inches high.

TR20

30 months

8.4.e               

The designated accessible toilet is inaccessible because the flush control is on the closed side.

ST2

30 months

8.5      

Concession Stand: Second Floor

   

8.5.a   

The counter is inaccessible because it is 42 inches high.

C6

30 months

8.5.b   

The dining tables near the snack area are inaccessible because none provides the required knee space.

PD3

30 months

8.6      

First Aid Counter: First Floor.  The counter is inaccessible because it is 41 inches high.

C6

30 months

8.7      

Pool Check-in Counter: First Floor.  The counter is inaccessible because it is 41 inches high.

C6

30 months

8.8      

Women's Locker Room: Pool Area First Floor

   

8.8.a   

The door is inaccessible because it requires 7 pounds of force to open.

D2

12 months

8.8.b   

The toilet in the ambulatory stall is not centered within the stall.

ST1

30 months

8.8.c   

The bench in the dressing area is inaccessible because it is less than 24 inches deep.

LR1

30 months

8.8.d   

There is no accessible locker provided.

LR3

30 months

8.8.e   

The air dryers in the dressing room are inaccessible because they are mounted 62 inches above the finished floor.

TR5

12 months

8.8.f    

The air dryers protrude into the walkway and are not detectable to blind persons using a cane.

AR8

12 months

8.8.g   

There is no accessible coat hook provided in the designated accessible toilet stall.

TR1

12 months

8.8.h   

The roll-in shower is inaccessible because it does not have grab bars on three walls.

B8

30 months

8.9      

Men's Locker Room Pool Area: First Floor

   

8.9.a   

The door is inaccessible because it requires 7 pounds of force to open.

D2

12 months

8.9.b   

The toilet in the ambulatory stall is not centered within the stall.

ST1

30 months

8.9.c   

The bench in the dressing area is inaccessible because it is less than 24 inches deep.

LR1

30 months

8.9.d   

There is no accessible locker provided.

LR3

30 months

8.9.e   

The air dryers in the dressing room are inaccessible because they are mounted 72 inches above the finished floor.

TR5

12 months

8.9.f    

The air dryers protrude into the walkway and are not detectable to blind persons using a cane.

AR8

12 months

8.9.g   

There is no accessible coat hook provided in the designated accessible toilet stall.

TR1

12 months

8.9.h   

The roll-in shower is inaccessible because it does not have grab bars on three walls.

B8

30 months

8.10    

Drinking Fountains: First Floor.  The drinking fountain protrudes into the walkway and is not detectable to blind persons using a cane.

AR8

12 months

8.11    

Women's Toilet Room With Stalls: First Floor

   

8.11.a 

The door is inaccessible because it requires 7 pounds of force to open.

D2

12 months

8.11.b 

The air dryer protrudes into the walkway and is not detectable to blind persons using a cane.

AR8

12 months

8.11.c 

The designated accessible toilet is inaccessible because the flush control is on the closed side.

ST2

30 months

8.11.d 

Although there are 6 toilet stalls, there is no ambulatory stall provided.

ST1

30 months

8.12    

Men's Toilet Room With Stalls: First Floor

   

8.12.a 

The door is inaccessible because it requires 7 pounds of force to open.

D2

12 months

8.12.b 

The air dryer protrudes into the walkway and is not detectable to blind persons using a cane.

AR8

12 months

8.12.c 

The designated accessible urinal is inaccessible because the rim is 18 inches high and the flush control is 46 inches high.

TR20

30 months

8.12.d 

The designated accessible toilet is inaccessible because the flush control is on the closed side.

ST2

30 months

8.12.e 

The designated accessible toilet is inaccessible because the centerline is 16½ inches from the side partition

ST17

30 months

8.13    

Women's Locker Room: First Floor

   

8.13.a 

The door is inaccessible because it requires 7 pounds of force to open.

D2

12 months

8.13.b 

The air dryer is inaccessible because it is mounted with the controls 57 inches high.

TR5

12 months

8.13.c 

The air dryer protrudes into the walkway and is not detectable to blind persons using a cane.

AR8

12 months

8.13.d 

The shower is inaccessible because the seat does not extend the full depth of the stall.

B10

30 months

8.13.e 

The bench in the dressing area is inaccessible because it is less than 24 inches deep.

LR1

30 months

8.13.f  

There is no accessible locker provided.

LR3

30 months

8.14    

Men's Locker Room: First Floor

   

8.14.a 

The door is inaccessible because it requires 7 pounds of force to open.

D2

12 months

8.14.b 

The air dryer is inaccessible because it is mounted with the controls 70½ inches high.

TR5

12 months

8.14.c 

The air dryer protrudes into the walkway and is not detectable to blind persons using a cane.

AR8

12 months

8.14.d 

The shower is inaccessible because the seat does not extend the full depth of the stall.

B10

30 months

8.14.e 

The bench in the dressing area is inaccessible because it is less than 24 inches deep.

LR1

30 months

8.14.f  

There is no accessible locker provided.

LR3

30 months

9         

BESSIE BRANHAM RECREATION CENTER, located at 2051 Brownwood Ave, SE

   

9.1      

Exterior Accessible Route: From Parking Lot to Main Entrance

   

9.1.a   

The curb ramp from the parking lot is inaccessible because it has flared sides that slope more than 10%.

AR5

30 months

9.1.b   

The ramp to the entrance has no level landing at the bottom, and the handrails do not have extensions at the bottom.

R5

30 months

9.2      

Building Entrances.  The building does not have directional signage posted at inaccessible entrances and does not have the International Symbol of Accessibility posted at accessible entrances.

D16

12 months

9.3      

Community Room.  The door is inaccessible because it requires 10 pounds of force to open.

D2

12 months

9.4      

Drinking Fountains.  The drinking fountains in the lobby and by the toilet rooms protrude into the walkway and are not detectable to blind persons using a cane.

AR8

12 months

9.5      

Men's Locker Room

   

9.5.a   

The door is inaccessible because it requires 10 pounds of force to open.

D2

12 months

9.5.b   

The lavatory is inaccessible because the rim or counter is 27 inches high to the top.

TR11

30 months

9.5.c   

The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact.

TR12

24 months

9.5.d   

The urinal is inaccessible because the  rim is 18 inches high.

TR20

30 months

9.5.e   

The air dryers protrude into the walkway and are not detectable to blind persons using a cane.

AR8

12 months

9.5.f    

The transfer shower stall is inaccessible because it is 48 inches by 36 inches, has a seat that does not extend the full depth of the stall, and does not have an adjustable height shower spray unit.

B8

30 months

9.5.g   

The benches in the dressing area are inaccessible because they are 9 inches deep, are not attached to the wall, and do not have adequate clear floor space alongside to allow a transfer.

LR1

30 months

9.5.h   

There are no accessible towel hooks provided.

TR1

12 months

9.5.i    

There is no accessible locker provided.

LR3

30 months

9.6      

Women's Locker Room

   

9.6.a   

The sign does not have raised or Braille characters.

TR18

24 months

9.6.b   

The door is inaccessible because it requires 10 pounds of force to open.

D2

12 months

9.6.c   

The soap dispenser is inaccessible because the controls are mounted 51 inches high over the lavatory.

TR4

12 months

9.6.d   

The designated accessible toilet is inaccessible because the centerline is 16½ inches from the side partition.

ST17

30 months

9.6.e   

The designated accessible toilet is inaccessible because the flush control is on the closed side.

ST2

30 months

9.6.f    

The air dryers protrude into the walkway and are not detectable to blind persons using a cane.

AR8

12 months

9.6.g   

The transfer shower stall is inaccessible because it is 48 inches by 36 inches, has a seat that does not extend the full depth of the stall, and does not have an adjustable height shower spray unit.

B8

30 months

9.6.h   

The benches in the dressing area are inaccessible because they are 9 inches deep, are not attached to the wall, and do not have adequate clear floor space alongside to allow a transfer.

LR1

30 months

9.6.i    

There are no accessible towel hooks provided.

TR1

12 months

9.6.j    

There is no accessible locker provided.

LR3

30 months

9.7      

Interior Accessible Route: Through New Section of Building

   

9.7.a   

The double door leading to the office and toilet room area is inaccessible because it requires 10 pounds of force to open.

D2

12 months

9.7.b   

The drinking fountain protrudes into the walkway and is not detectable to blind persons using a cane.

AR8

12 months

9.8      

AWDA Computer Classroom.  No accessible coat rack has been provided.

TR1

24 months

9.9      

Gymnasium.  The door is inaccessible because the door requires 8 pounds of force to open.

D2

12 months

9.10    

Exterior Drinking Fountain: Tennis Courts.  The drinking fountain is not accessible to people with disabilities.

DF1

30 months

9.11    

Exterior Accessible Route: To Urban Treehouse.  The walkway has a slope exceeding 5% but has no handrails.

R4

30 months

10       

UTOY CREEK WATER RECLAMATION CENTER, located at 805 Selig Drive, SW

   

10.1    

Parking Lot.  The van accessible parking reserved for persons with disabilities lacks the appropriate signage.

P6

24 months

10.2    

Interior Doors.  The interior doors throughout the facility require more than 5 pounds of force to open.

D2

12 months

10.3    

Drinking Fountains: Main/Second Level.  Although an accessible drinking fountain is provided, there is no fountain for people who have difficulty bending or stooping.

DF3

30 months

10.4    

Women's Toilet Room With Stalls: Second Floor

   

10.4.a 

The seat cover dispenser is inaccessible because it is mounted 62 inches high.

TR5

12 months

10.4.b 

The tampon dispenser is inaccessible because it requires pinching and twisting of the wrist to operate.

TR3

30 months

10.4.c 

The designated accessible stall is incorrectly configured as an ambulatory stall, and a standard accessible stall is not provided.

ST15

30 months

10.5    

Men's Toilet Room With Stalls: Second Floor

   

10.5.a 

The seat cover dispenser is inaccessible because it is mounted 61½ inches high.  

TR5

12 months

10.5.b 

The designated accessible stall is incorrectly configured as an ambulatory stall, and a standard accessible stall is not provided.

ST15

30 months

10.6    

Elevator.  The elevator is inaccessible because, although emergency communications are provided, the door to the controls  requires tight grasping and pinching to open.

E8

30 months

10.7    

Men's Toilet Room with Stalls: First Floor by Locker Rooms.  The toilet stall is incorrectly configured as an ambulatory stall, and a standard accessible stall is not provided.

ST15

30 months

10.8    

Men's Locker Room: First Floor

   

10.8.a 

There is no accessible locker provided.

LR3

30 months

10.8.b 

The shower stall is inaccessible because it lacks clear floor space beyond the transfer seat.

B8

30 months

10.9    

Women's Toilet Room with Stalls: First Floor by Locker Rooms

   

10.9.a 

The seat cover dispenser is inaccessible because it is mounted 56 inches high.

TR5

12 months

10.9.b 

The tampon dispenser is inaccessible because it requires pinching and twisting of the wrist to operate.

TR3

30 months

10.9.c 

The designated accessible toilet stall is incorrectly configured as an ambulatory stall, and there is no standard accessible stall provided.

ST15

30 months

10.10  

Women's Locker Room: First Floor

   

10.10.a           

There is no accessible locker provided.

LR3

30 months

10.10.b           

The shower stall is inaccessible because it lacks clear floor space beyond the transfer seat.

B8

30 months

10.11  

Drinking Fountains: First Floor

   

10.11.a           

The fountain by the auditorium protrudes into the walkway and is not detectable to blind persons using a cane.

AR8

12 months

10.11.b           

The wall-mounted fountain by the toilet rooms is inaccessible because the knee space is 26¼ inches high.

DF5

24 months

10.11.c           

Although an accessible drinking fountain is provided, there is no fountain accessible for people who have difficulty bending or stooping.

DF3

30 months

10.12  

Lower Level Auditorium

   

10.12.a           

The lower level auditorium, containing 73 fixed seats, is inaccessible because only 2 wheelchair seating areas are provided.  A total of 4 wheelchair seating areas is required.

AA6

30 months

10.12.b           

The auditorium is inaccessible to people with hearing disabilities because, although there are more than 50 fixed seats, there is no assistive listening system provided.  This auditorium requires 3 receivers.

AA4

30 months

10.13  

Men's Toilet Room With Stalls: Lower Level by Auditorium

   

10.13.a           

No accessible mirror has been provided.

TR14

12 months

10.13.b           

The seat cover dispenser is inaccessible because it is mounted 60 inches high.

TR5

12 months

10.13.c           

The designated accessible stall is incorrectly configured as an ambulatory stall, and a standard accessible stall is not provided.

ST15

30 months

10.14  

Women's Toilet Room With Stalls: Lower Level by Auditorium

   

10.14.a           

The toilet room is inaccessible because the door threshold is 1 inch high.

D22

24 months

10.14.b           

The seat cover dispenser is inaccessible because it is mounted 58 inches high.

TR5

12 months

10.14.c           

The tampon dispenser is inaccessible because it requires pinching and twisting of the wrist to operate.

TR3

 30 months

10.14.d           

The designated accessible stall is incorrectly configured as an ambulatory stall, and a standard accessible stall is not provided.

ST15

30 months

10.15  

Men's Locker Room: Lower Level

   

10.15.a           

There is no accessible locker provided.

LR3

12 months

10.15.b           

The bench is inaccessible because it is 9 inches wide and is not attached to the wall.

LR1

30 months

10.15.c           

The shower transfer seat is inaccessible because it does not extend the full depth of the shower.

B10

30 months

10.16  

Women's Locker Room: Lower Level

   

10.16.a           

There is no accessible locker provided.

LR3

30 months

10.16.b           

The bench is inaccessible because it is 9 inches wide and is not attached to the wall.

LR1

30 months

10.16.c           

The shower transfer seat is inaccessible because it does not extend the full depth of the shower.

B10

30 months

11       

WASHINGTON PARK TENNIS CENTER, located at 1125 Lena Street, NW, Building D

   

11.1    

Parking Lot

   

11.1.a 

The parking lot is inaccessible because the designated accessible parking spaces and access aisles have cross-slopes measuring between 6.6% and 7.5%.

P7

30 months

11.1.b 

The built-up curb ramp impermissibly extends into the required parking space's access aisle, and its flared sides slope more than 10%.

AR4

AR5

30 months

11.2    

Exterior Accessible Route: From Parking Lot to Main Entrance

   

11.2.a 

The route from the parking area to the entrance ramp is inaccessible because it has a slope of 7.2% and a cross-slope of 3.5%.

AR1

30 months

11.2.b 

The entrance ramp is inaccessible because it slopes 9.1% at the bottom, it lacks handrails along several portions, and it does not have adequate edge protection.

R3

30 months

11.3    

Drinking Fountain: Main Lobby:  Although an accessible drinking fountain is provided, it is not accessible for people who have difficulty bending or stooping.

DF3

30 months

11.4    

Alarms: Although the facility contains an emergency alarm system, not all common use areas have visual alarms.

AL1

12 months

11.5    

Men's Locker Room

   

11.5.a 

The door is inaccessible because it requires 18 pounds of force to open.

D2

12 months

11.5.b 

The transfer shower stall is inaccessible because it is 45 inches by 40½ inches, the transfer seat does not extend the full depth of the stall, and the controls are not on the open side of the stall.

B8

30 months

11.5.c 

The bench in the dressing room is inaccessible because it is 13½ inches wide and is not attached to the wall.

LR1

30 months

11.5.d 

No accessible coat hook has been provided.

TR1

12 months

11.5.e 

There is no accessible locker provided.

LR3

30 months

11.6    

Women's Locker Room

   

11.6.a 

The door is inaccessible because it requires 14 pounds of force to open.

D2

12 months

11.6.b 

The designated accessible toilet stall is inaccessible because it is 59 inches by 57 inches.

ST16

30 months

11.6.c 

The designated accessible toilet is inaccessible because the centerline is 19 inches from the side wall.

ST17

30 months

11.6.d 

The transfer shower stall is inaccessible because it is 40 inches by 40½ inches, the transfer seat does not extend the full depth of the stall, and the controls are not on the open side of the stall.

B8

30 months

11.6.e 

The bench in the dressing room is inaccessible because it is 13½ inches wide and is not attached to the wall.

LR1

30 months

11.6.f  

No accessible coat hook has been provided.

TR1

12 months

11.6.g 

There is no accessible locker provided.

LR3

30 months

11.7    

Exterior Accessible Route: Rear Exit Ramp to Tennis Courts.  The ramp has inadequate edge protection, handrails are not provided on several portions, and the handrails lack extensions.

R3

30 months

11.8    

Tennis Courts

   

11.8.a 

The tennis courts are inaccessible because the entrance has a step approximately 4 inches high.

AR1

30 months

11.8.b 

The seating area has no wheelchair seating available.

AA6

30 months

12       

ROSEL FANN RECREATION CENTER, located at 365 Cleveland Avenue, SE

   

12.1    

Parking Lot.  The parking lot, with a total of 103 parking spaces, has 4 designated accessible parking spaces, none of which is designated as van accessible, one of which has no vertical signage, and the other 3 of which have signage that is mounted too low.  This lot requires 1 van accessible space and 4 standard accessible spaces.

P3

30 months

12.2    

Exterior Accessible Route: Parking Lot to Main Entrance.  The running slope up to the main entrance is 6.4%, and there are no ramp features.

R3

30 months

12.3    

Interior Doors.  The doors throughout the facility are inaccessible because they require more than 5 pounds of force to open.

D2

12 months

12.4    

Concession Counter.  The counter is inaccessible because it is 42 inches high.

C5

30 months

12.5    

Classroom 203.  The computer is inaccessible because the computer table is 24½ inches high to the bottom.

C3

30 months

12.6    

Women's Toilet Room With Stalls: First Floor

   

12.6.a 

The toilet room sign is centered 69 inches high.

TR18

12 months

12.6.b 

The door is inaccessible because the threshold is ½ inch high and is not beveled.

D22

24 months

12.6.c 

No accessible mirror has been provided.

TR14

12 months

12.6.d 

The side grab bar at the designated accessible toilet is inaccessible because it is obstructed by the toilet paper dispenser.

ST8

12 months

12.6.e 

The air dryer protrudes into the walkway and is not detectable to blind persons using a cane.

AR8

12 months

12.7    

Men's Toilet Room With Stalls: First Floor

   

12.7.a 

The door is inaccessible because the threshold is ½ inch high and is not beveled.

D22

24 months

12.7.b 

No accessible mirror has been provided.

TR14

12 months

12.7.c 

The designated accessible toilet is inaccessible because the centerline is 19 inches from the side wall.

ST17

30 months

12.7.d 

The designated accessible toilet is inaccessible because the flush control is on the closed side.

ST2

30 months

12.7.e 

The side grab bar at the designated accessible toilet is inaccessible because it is obstructed by the toilet paper dispenser.

ST8

12 months

12.7.f  

The air dryer protrudes into the walkway and is not detectable to blind persons using a cane.

AR8

12 months

12.8    

Drinking Fountains: Upper Level.  Although two accessible drinking fountains are provided, there is no drinking fountain provided for people who have difficulty bending or stooping.

DF3

30 months

12.9    

Elevator

   

12.9.a 

The elevator is inaccessible because the main entry floor call button is not designated by a raised star.

E3

30 months

12.9.b 

The elevator is inaccessible because, although emergency communications are provided, the system is not identified by a raised symbol or lettering, the door to the system requires tight grasping or pinching to open, and the system does not work without voice communication.

E8

30 months

12.10  

Men's Toilet Room With Stalls: Lower Level

   

12.10.a           

The toilet room sign is centered 62 inches high and is mounted on the hinge side of the door.

TR18

12 months

12.10.b           

No accessible mirror has been provided.

TR14

12 months

12.10.c           

The urinal is inaccessible because the rim is 25 inches high.

TR20

30 months

12.10.d           

The side grab bar at the designated accessible toilet is inaccessible because it is obstructed by the toilet paper dispenser.

ST8

12 months

12.11  

Women's Toilet Room With Stalls: Lower Level

   

12.11.a           

The toilet room sign is mounted on the hinge side of the door.

TR18

12 months

12.11.b           

No accessible mirror has been provided.

TR14

12 months

12.11.c           

The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact.

TR12

24 months

12.11.d           

The designated accessible toilet stall is inaccessible because it is 48 inches wide.

ST16

30 months

12.11.e           

The designated accessible toilet is inaccessible because the flush control is on the closed side.

ST2

30 months

12.11.f

The side grab bar at the designated accessible toilet is inaccessible because it is obstructed by the toilet paper dispenser.

ST8

12 months

12.11.g           

The rear grab bar at the designated accessible toilet is inaccessible because it is mounted 7 inches from the near side wall.

ST4

12 months

12.12  

Drinking Fountains: Near Toilet Rooms and Elevator.  Although two drinking fountains are provided, there is no fountain for people who have trouble bending or stooping, and the water trajectory is 3 inches high on the existing fountains.

DF1

30 months

12.13  

Men's Locker Room: Lower Level Gym Side

   

12.13.a           

The air dryer protrudes into the walkway and is not detectable to blind persons using a cane.

AR8

12 months

12.13.b           

The designated accessible toilet is inaccessible because the centerline is 17 inches from the side wall.

ST17

30 months

12.13.c           

The designated accessible toilet is inaccessible because the flush control is on the closed side.

ST2

30 months

12.13.d           

The side grab bar at the designated accessible toilet is inaccessible because it is obstructed by the toilet paper dispenser.

ST8

12 months

12.13.e           

The transfer shower is inaccessible because it is 37 inches wide, the transfer seat is 20 inches above the finished floor, there is no clear floor space beyond the transfer seat, one of the grab bars is split in the middle, and the shower control is not on the open side of the shower.

B8

30 months

12.13.f

The benches are inaccessible because they are less than 24 inches wide and are not attached at the wall.

LR1

30 months

12.13.g           

There is no accessible locker provided.

LR3

30 months

12.14  

Women's Locker Room: Lower Level Pool Side

   

12.14.a           

The baby changing station is inaccessible because the handle is 56 inches high.

TR5

12 months

12.14.b           

The lavatory is inaccessible because the rim or counter is 27 inches high to the bottom.

TR11

30 months

12.14.c           

The air dryers protrude into the walkway and are not detectable to blind persons using a cane.

AR8

12 months

12.14.d           

The side grab bar at the designated accessible toilet is inaccessible because it is obstructed by the toilet paper dispenser.

ST8

12 months

12.14.e           

The shower stall is inaccessible because it lacks clear floor space beyond the transfer seat, the transfer seat is not "L" shaped, does not extend the full depth of the stall, and is 24 inches above the finished floor, one of the grab bars is split in the middle, and the shower control is not on the open side of the shower.

B8

30 months

12.14.f

The benches are inaccessible because they are less than 24 inches wide and are not attached at the wall.

LR1

30 months

12.14.g           

There is no accessible locker provided.

LR3

30 months

12.15  

Racquetball Court

   

12.15.a           

The racquetball court is inaccessible because the door has an opening width of 30 inches.

D25

30 months

12.15.b           

The door is inaccessible because the threshold is ¾ inches high.

D22

24 months

12.16  

Men's Locker Room: Lower Level Pool Side

   

12.16.a           

The men's locker room sign is not mounted 60 inches high.

TR18

12 months

12.16.b           

The air dryers protrude into the walkway and are not detectable to blind persons using a cane.

AR8

12 months

12.16.c           

The designated accessible toilet is inaccessible because the flush control is on the closed side.

ST2

30 months

12.16.d           

The side grab bar at the designated accessible toilet is inaccessible because it is obstructed by the toilet paper dispenser.

ST8

12 months

12.16.e           

The shower stall is inaccessible because it lacks clear floor space beyond the transfer seat, the transfer seat is not "L" shaped, does not extend the full depth of the stall, and is 24 inches above the finished floor, one of the grab bars is split in the middle, and the shower control is not on the open side of the shower.

B8

30 months

12.16.f

The benches are less than 24 inches wide and are not attached at the wall.

LR1

30 months

12.16.g           

There is no accessible locker provided.

LR3

30 months

13       

CLEVELAND AVENUE RECREATION CENTER, located at 47 Cleveland Avenue, SE

   

13.1    

Parking Lot.  The parking lot, with a total of 38 parking spaces, has no van accessible space, and one of the designated accessible parking spaces has no vertical signage.  This lot requires 1 van accessible space and 1 standard accessible space.

P3

30 months

13.2    

Exterior Accessible Route: Parking Lot to Main Entrance.  The curb ramp from the parking lot has a cross-slope of 3.1%.

AR5

30 months

13.3    

Recreation Room.  The door is inaccessible because it requires more than 5 pounds of force to open.

D2

12 months

13.4    

Men's Toilet Room With Stalls: Main Level

   

13.4.a 

The sign is mounted on the hinge side of the door.

TR18

12 months

13.4.b 

The door is inaccessible because it requires 8 pounds of force to open.

D2

12 months

13.4.c 

The push side of the door, which is accessed through a front approach and which has both a closer and a latch, is inaccessible because it has 7½ inches of clearance on the latch side.

D7

30 months

13.4.d 

The paper towel dispenser protrudes into the walkway and is not detectable to blind persons using a cane.

AR8

12 months

13.4.e 

The designated accessible stall is incorrectly configured as an ambulatory stall, and there is no standard accessible stall provided.

ST15

30 months

13.5    

Women's Toilet Room With Stalls: By Recreation Room Main Level

   

13.5.a 

The door is inaccessible because it requires 8 pounds of force to open.

D2

12 months

13.5.b 

The paper towel dispenser is inaccessible because it is mounted 55 inches high.

TR5

12 months

13.5.c 

The paper towel dispenser protrudes into the walkway and is not detectable to blind persons using a cane.

AR8

12 months

13.5.d 

The designated accessible stall is incorrectly configured as an ambulatory stall, and there is no standard accessible stall provided.

ST15

30 months

14       

BEN HILL RECREATION CENTER, located at 2405 Fairburn Road, SW

   

14.1    

Parking Lot.  The van accessible parking reserved for persons with disabilities lacks the appropriate signage.

P6

12 months

14.2    

Exterior Accessible Routes: To Tennis Court and Play Area.  The routes are inaccessible because they contain steps.

AR1

30 months

14.3    

Drinking Fountains: First Floor.  The drinking fountains protrude into the walkway and are not detectable to blind persons using a cane.

AR8

12 months

14.4    

Women's Toilet Room With Stalls: First Floor

   

14.4.a 

The room sign mounted on the latch side of the door is obstructed.

TR18

12 months

14.4.b 

The door is inaccessible because it requires 10 pounds of force to open.

D2

12 months

14.4.c 

The lavatory is inaccessible because the faucet requires tight grasping and twisting to operate.

TR10

24 months

14.4.d 

The air dryers protrude into the walkway and are not detectable to blind persons using a cane.

AR8

12 months

14.4.e 

The designated accessible toilet stall is inaccessible because it is 47 inches wide.

ST16

30 months

14.4.f  

The designated accessible toilet is inaccessible because the top of the seat is 20 inches high.

ST20

30 months

14.4.g 

The toilet paper dispenser is mounted on the wall opposite the side grab bar.

ST19

12 months

14.5    

Men's Toilet Room With Stalls: First Floor

   

14.5.a 

The door is inaccessible because it requires 10 pounds of force to open.

D2

12 months

14.5.b 

The lavatory is inaccessible because the faucet requires tight grasping and twisting to operate.

TR10

24 months

14.5.c 

The designated accessible stall is incorrectly configured as an ambulatory stall, and there is no standard accessible stall provided.

ST15

30 months

14.6    

Women's Locker Room: Lower Level

   

14.6.a 

The door is inaccessible because ir requires 9 pounds of force to open.

D2

12 months

14.6.b 

The designated accessible stall is incorrectly configured as an ambulatory stall, and there is no standard accessible stall provided.

ST15

30 months

14.6.c 

The designated accessible roll-in shower is inaccessible because it has grab bars on only 2 walls, and the seat is not mounted on the wall adjacent to the controls.

B8

30 months

14.6.d 

The route into the shower is inaccessible because there are only 72 inches of head room below the bar over the shower entrance.

AR7

12 months

14.6.e 

The bench is inaccessible because it is 9¼ inches wide and is not attached to the wall.

LR1

30 months

14.6.f  

The air dryer is inaccessible because the controls are 62½ inches high.

TR5

12 months

14.6.g 

There is no accessible locker provided.

LR3

30 months

14.7    

Mens Locker Room: Lower Level

   

14.7.a 

The door is inaccessible because ir requires 10 pounds of force to open.

D2

12 months

14.7.b 

The lavatory is inaccessible because the hot water pipes are not covered or configured to protect against contact.

TR12

24 months

14.7.c 

The designated accessible stall is incorrectly configured as an ambulatory stall, and there is no standard accessible stall provided.

ST15

30 months

14.7.d 

The air dryer is inaccessible because the controls are 58 inches high.

TR5

12 months

14.7.e 

The designated accessible transfer shower is inaccessible because it is 48 inches deep, and the controls are not mounted on the open side of the shower.

B8

30 months

14.7.f  

The route into the shower is inaccessible because there are only 74 inches of head room below the bar over the shower entrance.

AR7

12 months

14.7.g 

The bench is inaccessible because it is 9¼ inches wide and is not attached to the wall.

LR1

30 months

14.7.h 

There is no accessible locker provided.

LR3

30 months

14.8    

Weight Room: Lower Level.  The door is inaccessible because it requires 10 pounds of force to open.

D2

12 months

14.9    

Gymnasium

   

14.9.a 

The higher drinking fountain protrudes into the walkway and is not detectable to blind persons using a cane.

AR8

12 months

14.9.b 

The door is inaccessible because it requires 7 pounds of force to open.

D2

12 months

14.9.c 

The wheelchair seating area has no fixed companion seats.

AA6

30 months

15       

MORNINGSIDE RECREATION CENTER, located at 1053 E. Rock Springs Road, NE

   

15.1    

Parking Lot. The van accessible parking reserved for persons with disabilities lacks the appropriate signage.

P6

24 months

15.2    

Exterior Accessible Route: Ramp to Main Entrance.  The ramp slopes between 10.3% and 12.0%, and lacks handrail extensions.

R5

30 months

15.3    

Upper Level: Classroom.  The door is inaccessible because it requires 7 pounds of force to open.

D2

12 months

15.4    

Elevator.  The elevator is inoperable, and there is no other accessible route to other levels of the facility.

E1

30 months

15.5    

Unisex Single-User Toilet Room: Upper Level

   

15.5.a 

The toilet room sign is mounted on the door and does not have raised or Braille characters.

TR18

24 months

15.5.b 

The door is inaccessible because it requires 14 pounds of force to open.

D2

12 months

15.5.c 

The toilet is inaccessible because the top of the seat is 20 inches high.

SU18

30 months

15.5.d 

The toilet is inaccessible because its centerline is 20 inches from the side wall.

SU15

30 months

15.6    

Girl's Toilet Room With Stalls: Lower Level

   

15.6.a 

The toilet room sign is mounted on the door and does not have raised or Braille characters.

TR18

24 months

15.6.b 

The door is inaccessible because it requires 8 pounds of force to open.

D2

12 months

15.7    

Boy's Toilet Room With Stalls: Lower Level

   

15.7.a 

The toilet room sign is mounted on the door and does not have raised or Braille characters.

TR18

24 months

15.7.b 

The door is inaccessible because it requires 12 pounds of force to open.

D2

12 months

15.7.c 

The pull side of the door, which can be accessed from the latch side of the door, is inaccessible because it has only 10 inches of clear space on the latch side.

D10

30 months

16       

M. L. K. JR. RECREATION CENTER, located at 90 Boulevard Street, NE

   

16.1    

Parking Lot: Pool and MLK Recreation Center Shared Parking.  The parking lot, with a total of 42 parking spaces, has no accessible parking spaces.  This lot requires 1 van accessible space and 1 standard accessible space.

P3

30 months

16.2    

Exterior Accessible Route

   

16.2.a 

The route from the parking lot to the main entrance is inaccessible because it is often obstructed by parked cars.

AR1

12 months

16.2.b 

The route to the first floor gymnasium entrance (west) has a slope of 6.8% and has no ramp features.

R3

30 months

16.3    

Drinking Fountains

   

16.3.a 

The water flow on the lower drinking fountain on the first level is one inch high.

DF7

12 months

16.3.b 

The higher drinking fountain on each level protrudes into the walkway and is not detectable to blind persons using a cane.

AR8

12 months

16.4    

Women's Toilet Room With Stalls: Second Level

   

16.4.a 

The door is inaccessible because it requires 11 pounds of force to open.

D2

12 months

16.4.b 

The lavatory is inaccessible because the hot water pipes are not covered or configured to protect against contact.

TR12

24 months

16.5    

Men's Toilet Room With Stalls: Second Level

   

16.5.a 

The door is inaccessible because it requires 10 pounds of force to open.

D2

12 months

16.5.b 

The lavatory is inaccessible because the hot water pipes are not covered or configured to protect against contact.

TR12

24 months

16.5.c 

The urinal is inaccessible because the rim is 25 inches high and the flush control is 45 inches high.

TR20

30 months

16.6    

Women's Toilet Room With Stalls: First Level

   

16.6.a 

The door is inaccessible because it requires 11 pounds of force to open.

D2

12 months

16.6.b 

The soap dispenser is inaccessible because it is mounted with the controls 52 inches high with a forward reach required.

TR5

12 months

16.6.c 

The lavatory is inaccessible because the hot water pipes are not covered or configured to protect against contact.

TR12

24 months

16.7    

Men's Toilet Room With Stalls: First Level

   

16.7.a 

The door is inaccessible because it requires 11 pounds of force to open.

D2

12 months

16.7.b 

The lavatory is inaccessible because the hot water pipes are not covered or configured to protect against contact.

TR12

24 months

16.7.c 

The urinal is inaccessible because the rim is 25 inches high.

TR20

30 months

16.7.d 

The designated accessible toilet is inaccessible because the centerline is 19 inches from the side wall.

ST17

30 months

16.8    

Elevators

   

16.8.a 

The elevator is inaccessible because the hall call buttons are centered 38 inches high.

E3

24 months

16.8.b 

The elevator is inaccessible because, although emergency communications are provided, the system is not identified by raised symbols and lettering, the door to the emergency communications requires tight grasping or pinching to open, and the system does not work without voice communication.

E8

30 months

16.9    

Gymnasium

   

16.9.a 

The gymnasium has no wheelchair seating areas provided.

AA6

30 months

16.9.b 

The route through the gymnasium is inaccessible because there is an area where only 65 inches of head room is provided.

AR7

24 months

16.10  

First Level: Computer Room.  The door is inaccessible because it requires 10 pounds of force to open.

D2

12 months

16.11  

First Level: Arts and Crafts Room.  The door is inaccessible because it requires 9 pounds of force to open.

D2

12 months

17       

ATLANTA CITY DETENTION CENTER, located at 254 Peachtree Street, SW

   

17.1    

Parking Lot: Staff Only.  Although a designated van accessible parking space is provided, the vertical sign can be obstructed by a parked car, and the access aisle is 90 inches wide.

P3

30 months

17.2    

Ramp: Main Entrance.  The ramp has a handrail on only one side, and the existing handrail has no extension at the bottom.

R4

30 months

17.3    

Women's Toilet Room With Stalls: Lobby

   

17.3.a 

The door is inaccessible because it requires more than 5 pounds of force to open.

D2

12 months

17.3.b 

The latch on the designated accessible toilet stall door is broken and requires pinching and twisting of the wrist to operate.

TR3

24 months

17.3.c 

The designated accessible toilet is inaccessible because the rear grab bar is obstructed by the flush valve.

ST5

30 months

17.3.d 

No accessible coat hook has been provided.

TR1

12 months

17.4    

Men's Toilet Room With Stalls: Lobby

   

17.4.a 

The door is inaccessible because it requires more than 5 pounds of force to open.

D2

12 months

17.4.b 

The designated accessible toilet is inaccessible because the rear grab bar is obstructed by the flush valve.

ST5

30 months

17.4.c 

No accessible coat hook has been provided.

TR1

12 months

17.5    

Women's Toilet Room With Stalls: Staff Auditorium

   

17.5.a 

The door is inaccessible because it requires more than 5 pounds of force to open.

D2

30 months

17.5.b 

The feminine products dispenser and the air dryer protrude into the walkway and are not detectable to blind persons using a cane.

AR8

12 months

17.5.c 

The designated accessible toilet is inaccessible because the rear grab bar is obstructed by the flush valve.

ST5

30 months

17.5.d 

No accessible coat hook has been provided.

TR1

12 months

17.6    

Men's Toilet Room With Stalls: Staff Auditorium

   

17.6.a 

The door is inaccessible because it requires more than 5 pounds of force to open.

D2

12 months

17.6.b 

The designated accessible toilet is inaccessible because the rear grab bar is obstructed by the flush valve.

ST5

30 months

17.6.c 

No accessible coat hook has been provided.

TR1

12 months

17.7    

Elevators

   

17.7.a 

Both elevators are inaccessible because, although emergency communications are provided, the highest operable part is 57 inches above the elevator floor.

E8

30 months

17.7.b 

The elevator is inaccessible because the emergency controls are grouped at the top of the panel.

E9

30 months

17.8    

Drinking Fountains. The higher drinking fountains throughout the facility (except by the auditorium) protrude into the walkway and are not detectable to blind persons using a cane.

AR8

12 months

17.9    

Women's Single-User Staff Toilet Room: Administration Office Area

   

17.9.a 

The door is inaccessible because it requires more than 5 pounds of force to open.

D2

12 months

17.9.b 

No accessible coat hook has been provided.

TR1

12 months

17.9.c 

The toilet is inaccessible because the overall length of the rear grab bar is 30 inches and the flush valve and toilet cleanser interfere with its use.

SU2

30 months

17.10  

Men's Single-User Staff Toilet Room: Administration Office Area

   

17.10.a           

The door is inaccessible because it requires more than 5 pounds of force to open.

D2

12 months

17.10.b           

The toilet is inaccessible because the overall length of the rear grab bar is 30 inches and the flush valve and toilet cleanser interfere with its use.

SU2

30 months

17.11  

Telephones: Intake Area.  The telephones are inaccessible because they have cords less than 29 inches long.

TT1

24 months

17.12  

Housing Units.  The routes though the units are inaccessible because the undersides of the stairs pose an overhead hazard.

AR7

30 months

17.13  

Holding Cells 112 and 113.  No accessible mirror has been provided.

TR14

12 months

17.14  

Single-User Toilet Room: Women's Medical Unit Off Lobby.  The rear grab bar at the toilet is inaccessible because it is obstructed by the toilet flush valve.

SU4

30 months

17.15  

Single-User Toilet Room: Inmate Medical Unit.  The rear grab bar at the toilet is inaccessible because it is obstructed by the toilet flush valve.

SU4

30 months

17.16  

Single-User Toilet Room: Cell 118 3NE Maximum Security.   The toilet is inaccessible because there is no side grab bar provided.

SU5

24 months

17.17  

Single-User Toilet Room: 3SW Medical Dormitory.  The rear grab bar at the toilet is inaccessible because it is obstructed by the toilet flush valve.

SU4

30 months

17.18  

Shower Stalls: Cell 120 4NW Women's.  The designated accessible transfer shower is inaccessible because there is no transfer seat provided.

B10

30 months

17.19  

Shower Stalls:  Cell 104 4SE Women's.  The designated accessible transfer shower is inaccessible because there is no transfer seat provided.

B10

30 months

17.20  

Shower Stalls: 6NW.  The designated accessible shower is inaccessible because the control is missing.

B8

30 months

17.21  

Shower Stalls: 6SW.  The designated accessible shower is inaccessible because the control, transfer seat, and side grab bar are missing.

B8

30 months

17.22  

Shower Stalls: 6SE.  The designated accessible shower is inaccessible because the transfer seat is crooked.

B10

24 months

17.23  

Toilet Room With Stalls: 7NE Dormitory

   

17.23.a           

No accessible mirror has been provided.

TR14

12 months

17.23.b           

The designated accessible toilet is inaccessible because the rear grab bar is obstructed by the flush valve.

ST5

30 months

17.24  

Toilet Room With Stalls: 7NW Dormitory

   

17.24.a           

No accessible mirror has been provided.

TR14

12 months

17.24.b           

The designated accessible toilet is inaccessible because the rear grab bar is obstructed by the flush valve.

ST5

30 months

17.25  

Shower Stalls: 7NE.  The designated accessible shower is inaccessible because the control is missing.

B8

30 months

17.26  

Shower Stalls: 7NW.   The designated accessible transfer shower is inaccessible because there is no transfer seat provided.

B10

30 months

17.27  

Shower Stalls 7th Floor Housing Unit: 7SE.  The designated accessible shower is inaccessible because the control is missing.

B8

30 months

17.28  

Shower Stalls 7th Floor Housing Unit: 7SW.  The designated accessible shower is inaccessible because the control is missing.

B8

30 months

17.29  

Shower Stalls: 8SE.  The designated accessible shower is inaccessible because the control is missing.

B8

30 months

18       

ATLANTA FIRE STATION 33, located at 1401 South Loop Road

   

18.1    

Exterior Accessible Route: Parking Lot to Main Entrance.  The curb ramp from the parking lot slopes 10%, and the right side flare slopes 17.5%.

AR5

30 months

18.2    

Unisex Single-User Toilet Rooms: Main Entrance

   

18.2.a 

The toilet rooms are inaccessible because the doors require 7 pounds and 9 pounds of force to open.

D2

12 months

18.2.b 

No accessible mirror has been provided in either room.

TR14

12 months

18.2.c 

The toilet in each room is inaccessible because the top of the seat is 16 inches high.

SU18

30 months

18.2.d 

The toilet in each room is inaccessible because the centerline is 19 inches to 20½ inches from the side wall.

SU15

30 months

18.3    

Drinking Fountains: Near Main Entrance.  The higher drinking fountain protrudes into the walkway and is not detectable to blind persons using a cane.

AR8

12 months

18.4    

102 Conference Room.  The door is inaccessible because it requires 10 pounds of force to open.

D2

12 months

18.5    

104 Copy Room

   

18.5.a 

The door is inaccessible because it requires 17 pounds of force to open.

D2

12 months

18.5.b 

The cabinets along one wall protrude into the walkway and are not detectable to blind persons using a cane.

AR8

30 months

18.6    

106 Captain's Office and Dormitory

   

18.6.a 

The door is inaccessible because it requires 13 pounds of force to open.

D2

12 months

18.6.b 

No accessible mirror has been provided in the toilet room.

TR14

12 months

18.6.c 

The lavatory is inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact.

TR12

24 months

18.6.d 

The toilet is inaccessible because the top of the seat is 16 inches high.

SU18

12 months

18.6.e 

The toilet is inaccessible because there are no grab bars provided.

SU10

30 months

18.6.f  

The shower is inaccessible because it lacks a transfer seat and grab bars and has inadequate clear floor space to allow a transfer.

B8

30 months

18.6.g 

The bench is inaccessible because it is 9½ inches wide and is not attached at the wall.

LR1

30 months

18.7    

111 Storage Room/Bed.  The door is inaccessible because it requires 17 pounds of force to open.

D2

12 months

18.8    

150 EMS Supervisor/Captain Office.  The door is inaccessible because it requires 10 pounds of force to open.

D2

12 months

18.9    

149 Lieutenant's Office.  The door is inaccessible because it requires 9 pounds of force to open.

D2

12 months

18.10  

146 Lieutenant Dormitory.  The bench is inaccessible because it is 9½ inches wide and 36 inches long and is not attached at the wall.

LR1

30 months

18.11  

Lieutenant's Dorm

   

18.11.a           

No accessible mirror has been provided in either toilet room.

TR14

12 months

18.11.b           

The lavatories in each toilet room are inaccessible because the hot water pipes are not insulated or otherwise configured to protect against contact.

TR12

24 months

18.11.c           

The toilet in each room is inaccessible because the top of the seat is 15½ inches high

SU18

30 months

18.11.d           

The toilet in each room is inaccessible because the centerline is between 19 and 20½ inches from the side wall.

SU15

30 months

18.11.e           

The toilet in each room is inaccessible because there are no grab bars provided in either room.

SU10

30 months

18.11.f

The transfer shower stall in each room is inaccessible because it is 40 inches deep and has no transfer seat and no grab bars.

B8

30 months

18.11.g           

The bench is inaccessible because it is 9½ inches wide and 36 inches long and is not attached at the wall.

LR1

30 months

18.12  

116 Dormitory Room

   

18.12.a           

The door is inaccessible because it requires 9 pounds of force to open.

D2

12 months

18.12.b           

The women's and men's locker rooms are inaccessible because the doors require 7 and 14 pounds of force, respectively, to open.

D2

12 months

18.12.c           

No accessible mirror has been provided in either locker room.

TR14

12 months

18.12.d           

The designated accessible toilet in the women's and men's locker rooms is inaccessible because the centerline is 18½ inches and 17½ inches, respectively, from the side wall.

ST17

30 months

18.12.e           

The designated accessible toilet in each locker room is inaccessible because it has no grab bars provided.

ST11

30 months

18.12.f

The designated accessible transfer shower in each locker room is inaccessible because there is no transfer seat provided.

B10

30 months

18.12.g           

The designated accessible transfer shower in each locker room is inaccessible because there are no grab bars provided.

B9

30 months

18.12.h           

The bench in each locker room is inaccessible because it is 9½ inches wide and is not attached at the wall.

LR1

30 months

18.13  

132 Exercise Room.  The door is inaccessible because it requires 10 pounds of force to open.

D2

12 months

18.14  

133 Laundry Room.  The door is inaccessible because it requires 16 pounds of force to open.

D2

12 months

18.15  

141 Lockers.  The door is inaccessible because it requires 14 pounds of force to open.

D2

12 months

18.16  

138 Laundry Room.  The door is inaccessible because it requires 17 pounds of force to open.

D2

12 months

18.17  

137 Apparatus Room.  The door is inaccessible because it requires 14 pounds of force to open.

D2

12 months


 