Figure 36. Shower Seat Design.

An L-shaped shower seat is shown extending the full depth of the stall. The seat shall be located 1-1/2 inches (38 mm) maximum from the back and side walls. The front of the seat (nearest to the opening) shall extend a maximum 16 inches (330 mm) from the wall. The end of the seat (opposite the shower opening) shall extend a maximum of 23 inches (582 mm) from the side wall and shall be a maximum of 15 inches (305 mm) deep measured from the back wall.